G. Snodgrass, K. Ackles, A. Blanco and A. Versaggi Ortho Clinical Diagnostics, Rochester, NY 14626

Similar documents
USING THE ACCESS AMH ASSAY IN YOUR LABORATORY

Manual. Transfer step. Figure 1. Workflow comparison of manual phenylalanine assay and automated GSP Neonatal Phenylalanine assay

GLUH PRINCIPLE REF B ANNUAL REVIEW Reviewed by. Date. Date INTENDED USE

Evaluation Report: Eurolyser CRP test (ST0100 and ST0102) on. CUBE analyser (CA0100)

Kinetic assay of serum and urine for urea with use of urease and leucine dehydrogenase

Clinical Chemisty Reagents Brochure. ekfdiagnostics.com STANBIOChemistry from EKF Diagnostics. Central Laboratory

Acetoacetate Assay Kit (Colorimetric)

IDEXX Catalyst One Chemistry Analyzer for In-house Measurement of Total Thyroxine (TT 4 ) Concentration in Serum from Dogs and Cats

TABLE OF CONTENTS GENERAL INFORMATION... 1

1 Introduction Imprecision Within-run imprecision, results Day-to-day imprecision, results... 2

Gentian Canine CRP Immunoassay Application Note for Abbott Architect * c4000

LIPASE liquicolor. Design Verification. Multipurpose Reagent

Human Neurology 3-Plex A

Physiology Unit 1 METABOLISM OF LIPIDS AND PROTEINS

White Paper, Evaluation of WaveSense JAZZ Blood Glucose Monitoring System Analytical Performance to EN ISO 15197:2015 Standard

beta Hydroxybutyrate (beta HB) Assay Kit

Clinical Chemistry Reagents Brochure

Aspartate Transaminase (AST) Color Endpoint Assay Kit Manual Catalog #:

For In Vitro Diagnostic Use

liquicolor (AMP Buffer, IFCC) Design Verification

BIOO RESEARCH PRODUCTS. Aspartate Transaminase (AST) Color Endpoint Assay Kit Manual Catalog #:

Diagnostic reagent for quantitative in vitro determination of Urea / Blood Urea Nitrogen in serum, plasma and urine by colorimetry.

(a) y = 1.0x + 0.0; r = ; N = 60 (b) y = 1.0x + 0.0; r = ; N = Lot 1, Li-heparin whole blood, HbA1c (%)

25OH Vitamin D Total ELISA

The Virtues and Pitfalls of Implementing a New Test

A150 Product Number 31150

3 Linearity and Detection Limit Linearity Detection limit... 4

BIOO LIFE SCIENCE PRODUCTS

Gentian Canine CRP Immunoassay Application Note for scil VitroVet*

METHOD VALIDATION CASE

Β-FRUCTOFURANOSIDASE ENZYME

Human Hemoglobin Colorimetric Detection Kit

Clinical Chemistry (CHE 221)

1. PROTOCOL. Comparison Study Summary. Tuality Healthcare 324 SE 9 th Ave. Suite E Hillsboro, OR July 30, 2014

Evaluation of VACUETTE Urine CCM tube for Clinical Chemistry

Original Article Interfering effect of bilirubin on the determination of alkaline phosphatase

Applicable To Employees of Gundersen Boscobel Area Hospital Laboratory and Gundersen Palmer Lutheran Hospital and Clinics Laboratory.

Immunoenzymetric assay for the in vitro quantitative measurement of 25- hydroxyvitamin D 2 and D 3 (25OH-D 2 and 25OH-D 3 ) in serum.

Hexagon PSA. Design Verification. Contents

Validation Case studies: the good, the bad and the molecular

BASIC SCIENCES & BIOCHEMISTRY FOR BETZPAENIC BRIMBLERS

2 Screen Islet Cell Autoantibody Human ELISA

Patient: 55 y female (ambulatory)

SCIEX Vitamin D 200M Assay for the Topaz System

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY ASSAY AND INSTRUMENT COMBINATION TEMPLATE

For in vitro diagnostic use only. For Rx use only. Reviewed by Date Reviewed by Date

liquicolor Design Verification

Instructions for Use. Tg Antibody ELISA

Glucose Assay Kit. Catalog Number KA assays Version: 07. Intended for research use only.

OraSure Technologies, Inc Eaton Avenue, Bethlehem, PA Phone: (610) (USA) Fax: (610)

INSTRUCTIONS FOR USE

URINE DIPSTICK AND SULPHOSALICYLIC ACID TEST. Špela Borštnar UREX 2015, Ljubljana, Slovenia

This package insert contains information to run the Cholesterol assay on the ARCHITECT c Systems.

Journal of Dairy Science. TECHNICAL NOTE: Validation of BHBCheck blood β- hydroxybutyrate meter as a diagnostic tool for hyperketonemia.

5 BEST PRACTICES To Patient Safety. A Practical Guide to Blood Glucose Testing

Basic knowledge of POCT instuments. The Tide Resort Bangsan Beach 18 June 2009

This package insert contains information to run the Cholesterol assay on the ARCHITECT c Systems and the AEROSET System.

Triglyceride determination

Fructose-6-Phosphate Colorimetric Assay Kit

The Adiponectin Turbidimetric Immunoassay Reagent Kit

Determination of β-hydroxybutyrate in Blood and Urine Using Gas Chromatography Mass Spectrometry

QMS TACROLIMUS APPLICATION BECKMAN COULTER AU480 /AU680 /AU5800

Standard Operating Procedure

In Vitro Diagnostic Glucose Test System

GUIDE TO THE EVALUATION OF COMMUTABILITY OF CONTROL MATERIALS

IDEXX Catalyst SDMA Test for in-house measurement of SDMA concentration in serum from dogs and cats

assay Introduction Conclusions: The D-100 TM system proved to be a robust and reliable method for HbA 1c

Method Comparison Report Semi-Annual 1/5/2018

Determination of hemoglobin is one of the most commonly

Influenza A IgG ELISA

25OH Vitamin D Total ELISA

INSTRUCTIONS FOR USE

Non-Protein Nitrogenous Compounds. Non-Protein Nitrogenous Compounds. NPN s. Urea (BUN) Creatinine NH 3. University of Cincinnati MLS Program 1

23.1 Lipid Metabolism in Animals. Chapter 23. Micelles Lipid Metabolism in. Animals. Overview of Digestion Lipid Metabolism in

Comparison of Modified Jaffe s Kinetic Method and Enzymatic Method of Serum Creatinine Estimation for Precision, Linearity and Effect of Interferent

Lipid Metabolism * OpenStax

FreeStyle Lite A Blood Glucose Meter That Requires No Coding

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY ASSAY ONLY TEMPLATE

25-Hydroxy Vitamin D TOTAL (25HD) on Liaison XL

METHOD VALIDATION CASE

Insulin ELISA. For the quantitative determination of insulin in serum and plasma

en US: For in-vitro diagnostic use only.

Uni-Asia Scientific Instrument Company Limited. Stanbio Laboratory Product List

HbA1c3 PRINCIPLE REF B ANNUAL REVIEW Reviewed by. Date. Date INTENDED USE

Insulin (Porcine/Canine) ELISA

DIRECT ENZYMATIC HbA1c ASSAY

VetScan UA Urine Analyzer Clinical Performance Larry Lem, PhD & Andrew Rosenfeld, DVM, ABVP

BLOOD GLUCOSE METERS ACCURACY REQUIREMENTS

Sponsored and reviewed by ICCS Quality and Standards Committee Title: Verification of PNH assay sensitivity through spiking experiment Written by:

Experiment 3: Activity Determination

Evaluation Report. Eurolyser PT (INR) test kit (ST0180) on CUBE and smart analysers

Plasma Hemoglobin Determination: Two Manual Methods Compared. An Honors Thesis (HONRS 499) Anne M. Emerick. Sharlene Strahl. Beech Grove, Indiana

Evaluation Report. Eurolyser Lactate test kit (VT0220, VT0221) on solo analysers

FRCPath Part 1 written examination in Clinical Biochemistry

STELLUX C-peptide Chemiluminescence ELISA

The analytical phase

HbA1c enzymatic assay evaluation at AN academic

Evaluation Report. Eurolyser HbA1c Test Kit on Smart and Cube Analyser

Insulin ELISA. For the quantitative determination of insulin in serum and plasma.

Part III => METABOLISM and ENERGY. 3.4 Lipid Catabolism 3.4a Fatty Acid Degradation 3.4b Ketone Bodies

Transcription:

Performance of the EKF Diagnostics, Stanbio β-hydroxybutyrate LiquiColor Assay on the VITROS 4600 Chemistry System and the VITROS 5600 Integrated System. G. Snodgrass, K. Ackles, A. Blanco and A. Versaggi Ortho Clinical Diagnostics, Rochester, NY 14626

Introduction 2 The EKF Diagnostics, Stanbio β-hydroxybutyrate LiquiColor assay quantitatively determines the concentration of β-hydroxybutyrate (BHB) in serum or plasma. β-hydroxybutyrate, acetoacetate and acetone are three ketogenic byproducts from the metabolism of fatty acids. The byproducts are typically present in low concentration; however in disease state conditions such as diabetic ketoacidosis the levels are elevated, with β-hydroxybutyrate being present in the highest concentration. The traditional method for detecting the ketogenic byproducts is the qualitative nitroprusside test which detects only the ketone bodies acetoacetate and acetone, but fails to detect the ketoacid, β-hydroxybutyrate, the most prominent ketone body. Quantitatively measuring β-hydroxybutyrate provides a more accurate method for diagnosis and monitoring of diabetic ketoacidosis. Sources: 1. Sacks, DB et al. Guidelines and Recommendations for Laboratory Analysis and in the Diagnosis and Management of Diabetes Mellitus. Diabetes Care, 2011; 34:e61 e99. 2. Shiekh-Ali M, et al. Can Serum beta-hydroxybutyrate be used to diagnose diabetic ketoacidosis? Diabetes Care, 2008; 31:643-647.

Assay Method Overview 3 The performance of the Stanbio β-hydroxybutyrate LiquiColor assay on the VITROS 4600 Chemistry System (VITROS 4600) and the VITROS 5600 Integrated System (VITROS 5600) was evaluated. The assay was run on the VITROS MicroTip assay processing side of the MicroImmunoassay Center using 4.0uL of sample and the two Stanbio LiquiColor reagents. Endpoint absorbance measurements were taken at 510nm and converted to a concentration using a linear calibration model. The absorbance is directly proportional to the concentration of β-hydroxybutyrate in the sample.

Assay Enzymatic Reaction Scheme 4 D-3-Hydroxybutyrate dehydrogenase D-3-Hydroxybutyrate + NAD Acetoacetate + NADH + H + NADH + INT (oxidized) no color Diaphorase NAD + INT (reduced) reduced to red color Patient sample β-hydroxybutyrate in the presence of NAD is converted to acetoacetate and NADH by β-hydroxybutyrate dehydrogenase. NADH produced by this reaction reacts with 2-(4-iodophenyl)-3(4-nitrophenyl)-5-phenyl-2H-tetrazolium dye (INT) in the presence of diaphorase to generate a colorimetric signal at 510nm.

Method Comparison 5 A split sample comparison was conducted with 105 serum and plasma samples (0.05 12.56 mmol/l β-hydroxybutyrate ) using the VITROS 4600/5600 Systems and the Stanbio SIRRUS Clinical Chemistry Analyzer. The VITROS 4600 and VITROS 5600 Systems showed excellent correlation with the SIRRUS Analyzer. Data shown from VITROS 5600 Integrated System

Precision 6 Total within-laboratory precision was evaluated in accordance with CLSI EP05-A3 by evaluating β-hydroxybutyrate controls at 0.191 mmol/l and 4.224 mmol/l in duplicate twice per day for 28 days, for a total of 112 replicates. Precision components generated using Minitab software are shown for the VITROS 4600 and VITROS 5600 Systems. VITROS 4600 VITROS 5600 ANOVA Components Control 1 Control 2 Control 1 Control 2 Mean 0.194 4.214 0.188 4.234 Between-Day SD 0.002 0.017 0.001 0.016 Between-Run SD 0.001 0.017 0.001 0.023 Within-Run SD (Repeatability) 0.005 0.028 0.002 0.025 Total SD (Within-Lab) 0.005 0.037 0.002 0.037 Total %CV 2.58% 0.88% 1.06% 0.87% Within-Run %CV 2.58% 0.66% 1.06% 0.59%

Limit of Quantitation 7 The Limits of Blank (LoB), Detection (LoD) and Quantitation (LoQ) were determined in accordance with CLSI EP17-A2. LoB and LoD were determined by the non-parametric and parametric methods, respectively as described in the CLSI guideline. LoQ was determined by the precision profile approach as the predicted concentration at which the precision estimate was 10% CV. The values reported are the most conservative across the VITROS 4600 and VITROS 5600 Systems. VITROS System LoB (mmol/l) LoD (mmol/l) LoQ (mmol/l) 4600 / 5600 0.0102 0.0164 0.0315

Linearity 8 The linearity of the Stanbio β-hydroxybutyrate LiquiColor assay on the VITROS 4600 Chemistry System and the VITROS 5600 Integrated System was evaluated in accordance with CLSI EP06-A. The assessment was conducted using the Stanbio Laboratory TDM/beta-Hydroxybutyrate Linearity Standards. The observed linear range was 0.0 8.0 mmol/l BHB for both VITROS Systems. Data shown from VITROS 5600 Integrated System *Allowable bias = 0.1 mmol/l at [BHB] 1.0mmol/L, <10% at [BHB] > 1.0mmol/L

Onboard Reagent Stability 9 The stability of the Stanbio Laboratory β-hydroxybutyrate Liquicolor reagents while stored onboard the VITROS 4600 Chemistry System and the VITROS 5600 Integrated System was evaluated. Stanbio BHB Bi-level Controls were used as the test fluids with 4 replicates per timepoint. Mean values at each timepoint were plotted. Results indicate that the BHB reagent onboard stability is at least 8 weeks (56 days). Data shown from VITROS 5600 Integrated System

Calibration Stability 10 The calibration stability of the Stanbio β-hydroxybutyrate LiquiColor assay on the VITROS 4600 Chemistry System and the VITROS 5600 Integrated System was evaluated. Stanbio BHB Bi-level Controls were used as the test fluids over 28 test days (53 cumulative days). Total replicates = 112. Results indicate that the BHB assay calibration stability is at least 53 days. Data shown from VITROS 5600 Integrated System

Specificity 11 Using the paired difference method from CLSI guideline EP07-A2 the performance of the Stanbio β-hydroxybutyrate LiquiColor assay on the VITROS 4600 Chemistry System and the VITROS 5600 Integrated System was assessed in the presence of common endogenous substances. Endogenous substances at various concentrations were spiked into a 1.5 mmol/l β-hydroxybutyrate serum patient sample pool and evaluated for assay interference. The values reported are the highest concentration of each endogenous substance which met the assay acceptance criteria for interference. Endogenous Substance VITROS 4600 VITROS 5600 Hemoglobin, mg/dl 600 600 Bilirubin - Unconjugated, mg/dl 40 40 Bilirubin - Conjugated, mg/dl 40 40 Triglycerides (Intralipid ), mg/dl 1600 1600

Conclusions 12 The performance of the EKF Diagnostics, Stanbio β-hydroxybutyrate LiquiColor assay on the VITROS 4600 Chemistry System and the VITROS 5600 Integrated System was evaluated. The assay exhibited the following: Excellent correlation with the SIRRUS Clinical Chemistry Analyzer Excellent Within-Lab precision and low end sensitivity Onboard reagent stability to at least 56 days Calibration stability to at least 53 days The assay was free from interference by endogenous substances at a clinically relevant β-hydroxybutyrate concentration.