Femoral neck osteotomy guide for total hip arthroplasty

Similar documents
Leg Length Discrepancy in a Patient with Ipsilateral Total Knee and Total Hip Arthroplasty

CLINICAL PAPER / ORTHOPEDIC

A 42-year-old patient presenting with femoral

The Leg Length Discrepancy in The Entire Lower Limbs after Total Hip Arthroplasty Influences The Coronal Alignment of Pelvis and Spine.

Leg-length Inequalities Following THA Based on Surgical Technique

Digital Templating of the Non-Affected Hip as a Means of Minimizing Leg-Length Discrepancy after Primary Total Hip Arthroplasty

Effect of Superior Placement of the Hip Center on Abductor Muscle Strength in Total Hip Arthroplasty

Femoral neck fracture during physical therapy following surface replacement arthroplasty: a preventable complication?

Preoperative Planning. The primary objectives of preoperative planning are to:

Clinical Evaluation Surgical Technique

Predicting the Position of the Femoral Head Center

Surgical Technique. Hip System

Optimum implant geometry

New technique: practical procedure of robotic arm-assisted (MAKO) total hip arthroplasty

Re-growth of an incomplete discoid lateral meniscus after arthroscopic partial resection in an 11 year-old boy: a case report

9800 Metric Blvd. Austin, Texas

Total Hip Arthroplasty Performed Using Conventional and Computer-Assisted, Tissue- Preserving Techniques 6

VerSys LD/Fx Cemented and Press-Fit Hip Prostheses. Surgical Technique IMAGE TO COME. Versatile solutions for total and partial hip replacement

Navigation for total hip arthroplasty

Surgical Technique. *smith&nephew POLARSTEM Cementless Stem System

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

Zimmer M/L Taper Hip Prosthesis. Surgical Technique

Leg length discrepancy After Total Hip Replacement: Prevalence And impact on functional outcome

Bone Preservation Stem

HIP SOFTWARE-GUIDED SURGERY

Orthopedic Pre-operative Planning and Templating with Digital X-ray Images

operative technique Kent Hip

THE NATURAL FIT. Surgical Technique. Hip Knee Spine Navigation

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

TaperFill. Surgical Technique

PAL Pelvic Alignment Level

Case Report Anterior Subluxation after Total Hip Replacement Confirmed by Radiographs: Report of Two Cases

HELIOS h i p s y s t e m

Conservative Correction of Leg-Length Discrepancies of 10 mm or Less for the Relief of Chronic Low Back Pain

HIP FOLLOW-UP. Thank you for your attention to this matter. If you have any questions, please contact us for assistance. Thomas P.

Fixed and Variable Geometry Total Shoulder Arthroplasty

Metha Short Hip Stem System

AML Hip System. Design Rationale/ Surgical Technique

Case Report. Antegrade Femur Lengthening with the PRECICE Limb Lengthening Technology

Effectiveness of the surgical torque limiter: a model comparing drill- and hand-based screw insertion into locking plates

HIP SYSTEM SURGICAL TECHNIQUE

Bioscience Research Print ISSN: Online ISSN:

*smith&nephew CONTOUR

Leg Length Discrepancy after Total Hip Arthroplasty Using the Modified Anterolateral Approach for Stable Hip

Following a tradition of success. VerSys Heritage Primary Hip Prosthesis Surgical Technique

Burwood Road, Concord 160 Belmore Road, Randwick

Ye-Ran Li, Yu-Hang Gao, Xin Qi *, Jian-Guo Liu, Lu Ding, Chen Yang, Zheng Zhang and Shu-Qiang Li

A preliminary evaluation of raising the center of rotation in total hip arthroplasty for the patients with developmental dysplasia of the hip

Chronic Lymphedema of the Lower Limb: A Rare Cause of Dislocation of Total Hip Arthroplasty

Lateral femoral traction pin entry: risk to the. femoral artery and other medial neurovascular structures

Alignment Rod. For intraoperatively confirming correction of the mechanical leg axis.

Anterior Approach Surgical Technique. Paragon Stem System. enabling people to enjoy life

The arc of pelvic motion has been shown to be as great as 70 through sit to stand activities 1 DiGioia CORR 2006

JOINT RULER. Surgical Technique For Knee Joint JRReplacement

ACETABULAR CUP SURGICAL TECHNIQUE

VerSys 6 Beaded FullCoat Plus Hip Prosthesis

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Approach Patients with Confidence

Comparison of high-flex and conventional implants for bilateral total knee arthroplasty

PLR. Proximal Loading Revision Hip System

Case Report Bilateral Distal Femoral Nailing in a Rare Symmetrical Periprosthetic Knee Fracture

Ovation Hip System. Surgical Technique

The updated incidences and mortalities of major cancers in China, 2011

Total Hip Replacement. Find out why the Anterior Approach may be right for you.

Distal Cut First Femoral Preparation

Approach Patients with Confidence

Surgical Technique. CONQUEST FN Femoral Neck Fracture System

Bipolar Radial Head System

EXAMINATION OF HIP. A. Inspection Examination

Cup Alignment Error Model for Total Hip Arthroplasty

EMPERION Modular Hip System Surgical Technique

Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5.

A Useful Reference Guide for the Stem Anteversion During Total Hip Arthroplasty in the Dysplastic Femur

Swiss Medical Network Musculoskeletal Conference Surgical Technique and 30-Year Results of the Periacetabular Osteotomy (PAO)

Surgical Technique r5.indd 1 12/8/10 10:36 AM

CLINICAL AND OPERATIVE APPROACH FOR TOTAL KNEE REPLACEMENT DR.VINMAIE ORTHOPAEDICS PG 2 ND YEAR

Approach Patients with CONFIDENCE

SCALING Radiographic Technique

Journal of Foot and Ankle Research

Tradition Hip Primary Surgical Technique

CC TRIO VERSAFITCUP. Surgical Technique. each to their own. Hip Knee Spine Navigation

Effect of Anesthesia Type on Limb Length Discrepancy After Total Hip Arthroplasty

APS Natural-Hip System

21st Century Fracture Management ETS. Surgical Protocol

Multiapical Deformities p. 97 Osteotomy Concepts and Frontal Plane Realignment p. 99 Angulation Correction Axis (ACA) p. 99 Bisector Lines p.

Aesculap Trilliance Triple Tapered Polished Hip Stem

Sectra Orthopaedic Solutions

Surgical technique. Dynamic Simulation Personalised Solution

INVISION Total Ankle Replacement System with PROPHECY Preoperative Navigation Revision of a Failed Agility Total Ankle Replacement

Effect of surgical approach on the early outcome of total hip replacement for femoral neck fractures

One Stage or Two Stage

Total Hip and Knee arthroplasty in a patient with osteopetrosis: a case report and review of the literature

Total Knee Original System Primary Surgical Technique

Aesculap Targon FN. Head Preserving Solution for Medial Femoral Neck Fractures. Aesculap Orthopaedics

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

RECOVERY. P r o t r u s i o

VerSys Fiber Metal Taper Hip Prosthesis. Surgical Technique

Progeny Hip Stem. Surgical Protocol and Product Specifications

DFS Hip Distractor. Surgical Technique

Transcription:

Yang et al. BMC Surgery (2015) 15:29 DOI 10.1186/s12893-015-0015-3 RESEARCH ARTICLE Open Access Femoral neck osteotomy guide for total hip arthroplasty Lei Yang, Zhanle Zheng, Wei Chen, Juan Wang and Yingze Zhang * Abstract Background: Total hip arthroplasty (THA) is a common last-resort treatment for hip disease, but postoperative patients often complain of discrepancies in leg length. This study introduces a device designed to increase the precision of the femoral neck osteotomy and reduce the incidence of leg length discrepancy. Methods: Forty-eight patients undergoing THA were divided into two groups, with and without the use of the femoral osteotomy guide. All operations were performed through a posterolateral approach. Differences in leg length were recorded before and after the operation. Measurements were also made to compare the preoperative plan with the actual amount of bone removed. Results: The mean average difference in femoral neck resection height was 0.84 mm when using the osteotomy guide and 1.69 mm without the guide. Discrepancies in postoperative leg length were 5.45 mm and 13.37 mm in the groups with and without the guide, respectively. Conclusion: The femoral neck osteotomy guide is an effectively auxiliary tool for increasing the accuracy of bone resection in arthroplasty using the posterolateral approach. Trial registration: ChiCTR-OOC-15005904; date: 2015-01-30 Keywords: Guide, Femoral neck osteotomy, Osteotomy guide, Total hip arthroplasty, Leg length discrepancy Background Total hip arthroplasty (THA) is the most effective surgical approach for reducing pain and preserving function in heavily degraded joints [1]. Leg length discrepancy (LLD) of 2-3 cm is critical for the clinical outcomes. Older patients may have problems with LLD as small as 2 cm. But Clark et al reported patients complained when LLD was 1 cm [2]. The procedure requires removing a certain degree of bone block from the femoral head and neck and often results in a post-surgical LLD, a problem that surgeons have long-sought to rectify. The position of the femoral neck osteotomy is one of the crucial factors in avoiding LLD [3]. To fit the hip joint prostheses during THA, the planes and angles of the femoral neck osteotomy require stringent control. Typically, a surgeon can only rely on his or her own experience with the procedure, which can often lead to errors between the * Correspondence: dryzzhang@126.com Equal contributors Department of Orthopaedic Surgery and Key Biomechanical Laboratory of Orthopaedics of Hebei Province, The Third Hospital of Hebei Medical University, Shijiazhuang 050051, China planned fitting and the actual surgical alignment. This practice is not conducive to patient rehabilitation because it not only extends the operative time but also affects the results of the operation. To improve the accuracy of the femoral neck osteotomy, we designed a femoral neck osteotomy guide and compared its performance against a commonly-used unguided osteotomy technique. This study aims to introduce and assess the reliability of the guide designed for osteotomy in THA. Methods Structure of the femoral neck osteotomy guide The femoral neck osteotomy guide (Figure 1) consists of two parts: the upper part is an oriented platform that guides the direction of the femoral neck osteotomy perpendicular to the long axis of femoral neck, and the lower part locates on the top of the lesser trochanter of the femur. There are two fixed screw holes in the locating seat, which are used to fix the device on the femoral neck. The guides were divided into left and right groups, and a series of the guides was designed according to the 2015 Yang et al.; licensee BioMed Central. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Yang et al. BMC Surgery (2015) 15:29 Page 2 of 6 Figure 1 Femoral Neck Osteotomy Guide A: anterior view, B: posterior view. The guide device comprising two parts, the upper oriented platform (1) and the lower locating seat, which is attached to the top of the lesser femoral trochanter (2). osteotomy height from 10 mm to 15 mm for each group. The series contains six models with a 1 mm interval difference between each two adjacent models. The different sizes of the osteotomy guides were selected according to preoperative templates on X-ray films, such as a 10-mm guide for a 10 mm osteotomy height, and the like. First, a model was made and modified on femur specimens using a self-curing denture acrylic. The model was then tested and adjusted on 128 femur specimens to obtain a suitable model form for a variety of femoral neck configurations. Finally the guide was made from titanium with a ratio of 1:1 according to the model. The guide was suitable for THA through a posterolateral approach. Before surgery, the device was sterilised with low temperature hydrogen peroxide gas plasma sterilisation. Patients This study aimed to investigate the precision of the guide for THA. Between November 2012 and July 2013, 48 patients in need of femoral neck osteotomy were included in our study (Figure 2). Inclusion criteria were: primary hip arthroplasty with limb-length discrepancy less than 5 mm. In these patients, only one side required hip replacement while the other side was normal. Exclusion criteria were: preoperative LLD > 5 mm by tape measurement, total hip arthroplasty with femoral neck preservation and a history of previous hip surgery. Patients were also excluded from the study if they had obesity, rheumatoid arthritis, scoliosis, pelvic obliquity, or a limp caused by cerebral thrombosis, cerebral palsy and other causes. The selected patients were randomly assigned into the two groups. Twenty-four patients were operated on with the use of the guide (group I) and 24 without the guide (group II). All operations were performed by the same experienced surgeon and measurements were made by a member of the research team. The surgical team consisted of surgeons with more than 10 years of experience 14 cases Hip replacement revision operations 172 cases from November 2012 to July 2013 15 cases LLD>5mm before the operation 42 cases THA with femoral neck preservation 47 cases Bilateral hip replacement 48 cases for the study 2 cases with BMI>31 4 cases patients with rheumatoid arthritis Included Excluded Included Figure 2 Flowchart illustrates the patients selected for study.

Yang et al. BMC Surgery (2015) 15:29 Page 3 of 6 in hip replacement. Data on age, gender, operation side, an etiology of surgical indications, femoral neck height, leg length and operative time were collected for both groups. Surgical techniques All patients were admitted to the hospital 3-5 days before the surgery. Leg length was calculated and recorded by tape measure with the patients in a supine position before and after the THA surgery. The length of the lower limbs was measured between the anterior superior iliac spine (ASIS) and the medial malleolus [4]. Preoperative radiographs were taken from an anteroposterior view of the pelvis with both femurs internally rotated approximately 15 as required for assessment before THA. The templates were used to determine the height of the femoral neck osteotomy and the potential correct sizes for both the acetabular and femoral components of the prostheses. After surgery, the heights of the osteotomies were measured from the lesser trochanter to the cuneiform plane on the X-ray films using the same parameters. The operations were performed through a posterolateral approach with patients in a lateral decubitus position. After exposing the femoral neck and the lesser trochanter, the surgeon placed the guide on the lesser trochanter. It is important to place the locating seat on the top of the lesser trochanter and to adjust the oriented platform to be perpendicular to the long axis of the femoral neck. The height of the bone resection is determined by the height of the guide, but the angle of the osteotomy was adjusted by lifting or lowering the platform of the guide by eye by the surgeons based on their experience. After fixing the guide with Kirschner pins at a diameter of 2 mm, the guide was fastened to femoral neck, making it unnecessary to hold the device tightly against the bone while performing the resection. Intraoperative X-ray was not performed after positioning the guide in front of the osteotomy. The surgeon cut the femoral neck while the saw was in contact with the guide platform (Figure 3). After the bone was resected, the device was removed to show a smooth bone platform perpendicular to the long axis of the femur (Figure 4). The prosthesis was then placed following the customary surgical steps and post-operative X-rays were taken. For group II, the same procedure was followed, with the exception of using the guide. The Institutional Review Board of the Third Hospital of Hebei Medical University approved this study after thorough examination and verification. All patients signed informed consent and agreed to participate in the study. Figure 3 Before osteotomy: the device is secured on the top of the lesser trochanter by the locating seat and fixed with 2.0 Kirschner pins after adjusting the angle. aetiologies of indications and operative side were compared by the Chi-squared test. Measurement data, such as age, were compared using a t-test. The significance threshold was set at P < 0.05. Results A total of 48 patients participated in the study. Gender, age, operative side and clinical data were collected for statistical analysis, with results showing no significant difference between the two groups (Table 1). Difference existed between the planning and postoperative osteotomy heights in both group, but the mean difference in group I (average, 0.84 mm) was significantly less than group II(average, 1.69 mm) (P < 0.001) (Tables 2 and 3). Patients undergoing THA in group II had an average difference in osteotomy height of 1.69 mm, while group I had an average difference of only 0.84 mm, which was Statistics Statistical analysis was carried out by using SPSS13.0 for Windows (SPSS, Chicago, IL, USA). Enumeration data of the two groups of patients organised by gender, Figure 4 Showing the platform after osteotomy after the guide has been removed.

Yang et al. BMC Surgery (2015) 15:29 Page 4 of 6 Table 1 Characteristics of the two groups Group I Group II Statistic P value NS Number of patients 24 24 Male 15 11 X 2 = 1.343 0.247 * Female 9 13 Mean age(yrs) 52.31 (range,22-83) 54.55 (range,25-78) t = 0.448 0.657 * Operation side X 2 = 2.116 0.146 * Left 11 16 Right 13 8 Aetiology of indications X 2 = 1.532 0.655 * Femoral head necrosis 16 18 Femoral neck fracture 3 4 Primary osteoarthritis 5 2 NS: non-significant. *: P>0.05. significantly less than in group II (P < 0.001) (Table 4). The guide group had an average postoperative LLD of 5.45 mm, while group II had an average LLD of 13.37 mm. Additionally, limb shortening occurred in patients in group II but this was not observed in any patients in group I (Table 5). For both groups, there was no significant difference in operation time (p = 0.406), but the average time for group I was four minutes shorter than that in group II (Table 6). No complications occurred in either group during the process of osteotomy. Discussion The study focused on introducing and evaluating the femoral neck osteotomy guide, consisting of the oriented part and locating part. The guide was designed for improving the accuracy of osteotomy during THA surgery through the posterolateral approach. The difference between actual and planning osteotomy heights in the group with the guide was lower than that in the group without the guide. In addition, the guide is easy to use and does not prolong the operation time. Hip replacement is currently one of the most effective treatments for severely diseased or degenerated hip joints. More than 1 million hip arthroplasties are performed every year worldwide, and this number is projected to double within the next two decades [1]. The incidence of LLD after THA has been reported to range from 1% to 27%, with some reports of even up to 50%. It is difficult to eliminate LLD after THA. Combined use of a preoperative femoral template to predict the necessary length correction and plan the femoral neck osteotomy level along with intraoperative measurements is a practical method for avoiding LLD. However, some studies concluded that a planning match exists in only up to 60% of cases, so improving the accuracy of actual performance according to preoperative plan remains controversial [3,5]. LLD following hip replacement may cause lower back pain, sciatic nerve palsy, gait dysfunction, hip dislocation and prosthetic loosening, as well as increasing patient dissatisfaction. LLD has been a major post-surgical complaint for patients receiving hip arthroplasty [6]. LLD is the result of a complex interaction between bone length, implants, soft tissue contractures, and pelvic obliquities. After THA surgery, some authors feel that over-lengthening of the implant head-neck distance resulted in LLD [7,8]. In addition, the restoration of femoral offset is also critical for avoiding LLD, as increased femoral offset theoretically can lead to increased implant bending moments and early loosening. During the operation, inaccurate abduction/adduction repositioning of the femur with respect to the pelvis also can cause substantial errors in the measurement of length and offset change [9]. A variety of methods have been used to avoid or reduce the incidence of LLD, such as preoperative template measurement or using an L-shaped calliper and other surgical devices [10]. Careful preoperative planning is critical but does not preclude the surgeon from choosing the incorrect components for THA. More importantly, attention to detail both in the planning and performance of the surgery may assist in reducing LLD [11]. Although meticulous preoperative templating combined with X-ray, CT and other Table 2 Planning and postoperative osteotomy height in group I (mm) Planning 1.30 ± 0.22 10.126 < 0.001 Postoperative 2.14 ± 0.34 Table 3 Planning and postoperative osteotomy height in group II (mm) Planning 1.27 ± 0.22 13.196 < 0.001 Postoperative 2.96 ± 0.59

Yang et al. BMC Surgery (2015) 15:29 Page 5 of 6 Table 4 Difference in osteotomy height of femoral neck between two groups (mm) Group I 0.84 ± 0.22 5.567 < 0.001 Group II 1.69 ± 0.72 Table 6 Difference in operation time between two groups (min) Group I 125.00 ± 17.45 0.838 0.406 Group II 129.13 ± 15.93 imaging systems assists with sizing an appropriate prosthesis and can be helpful for avoiding LLD, surgeons may unintentionally stray from the template when implants of different sizes or offsets are used [2]. Although some instrumentswereusedformeasuringduringthesurgery,no professional surgical tools such as those used in knee replacement surgery exist for femoral neck resection. Surgeons typically rely on their experience and finger measurements during the osteotomy. This may be particularly difficult for inexperienced surgeons, especially when trying to gauge the cuneiform plane angle and height of the femoral neck resection. This can extend the operation time, increase blood loss and complicate the procedure. Earlier studies paid close attention to measurement methods using different types of devices and landmarks, but difficulties with operative manipulation have not been addressed thus far. The guide was invented to address the uncertainty of femoral neck osteotomy. In our study, the surgeons had more than 10 years of experience in hip replacement, yet still had a certain degree of error. In the current study, errors in osteotomy height between the actual and predicted size were reduced to 0 ~ 1 mm. Furthermore, LLD was reduced to less than 10 mm. We believe that such a device will become standard in femoral neck osteotomy, resulting in more precision for cutting height and resection angles. This will also reduce the surgical times and alleviate soft tissue damage during the operation. Our study has some limitations. First, the head-neck distance of the implants was not recorded or compared between the two groups. A device combined femoral neck osteotomy guide with head-neck distance measurement is being developed. Second, in our study, one observer who was blinded to the design was in charge of measurement, so inter-observer agreement was not considered in the design of the study. This was one of the major limitations of the current study. Finally, the soft tissues above the lesser trochanter could not be stripped clean during surgery, which introduced a measurement error in performing the osteotomy. Additionally, in obese patients, it is difficult to Table 5 LLD between the two groups (mm) Group I 5.45 ± 2.23 7.609 < 0.001 Group II 13.37 ± 4.58 expose the lesser trochanter, so the device cannot accommodate all types of patients in clinical practice. Conclusions The guide device, as an auxiliary tool, assists the surgeon in achieving a more precise femoral neck osteotomy according to the preoperative plan, which may also reduce the incidence of LLD. The design still has some limitations, and there is more room for improvement. First, the guide with its fixed height is not convenient in clinical application. If the height of device was adjustable, the surgeon could alter the osteotomy height without removing the location seat. This problem could be solved by adding a gasket on the platform of the device; we are currently working on that modification. Second, the adjustment of the angles in bone resection still depends on the surgeon s experience; this is another area that needs improvement. The design will be further refined to improve the tool s functionality. Competing interests The authors declare that they have no competing interests. Authors contributions YZ conceived the study. LY, ZZ, JW and WC were responsible for data management and statistical analyses. All authors were responsible for the interpretation of the data. LY wrote the report and all authors read and approved the final manuscript. LY and ZZ contributed equally to this article and are co-first authors. All authors read and approved the final manuscript. Acknowledgements The authors thank Dr. Fei Wang, Dr. Yongtai Han and the Key Biomechanical Laboratory of Orthopaedics of Hebei Province, for their valuable comments. We also thank Dr. CK Cheng for English language editing. Received: 15 May 2014 Accepted: 24 February 2015 References 1. Pivec R, Johnson AJ, Mears SC, Mont MA. Hip arthroplasty. Lancet. 2012;380 (9855):1768 77. 2. Clark CR, Huddleston HD, Schoch 3rd EP, Thomas BJ. Leg-length discrepancy after total hip arthroplasty. J Am Acad Ortho Surg. 2006;14(1):38 45. 3. Desai AS, Dramis A, Board TN. Leg length discrepancy after total hip arthroplasty: a review of literature. Curr Rev Musc Med. 2013;6(4):336 41. 4. Jamaluddin S, Sulaiman AR, Imran MK, Juhara H, Ezane MA, Nordin S. Reliability and accuracy of the tape measurement method with a nearest reading of 5 mm in the assessment of leg length discrepancy. Singap Med J. 2011;52(9):681 4. 5. Knight JL, Atwater RD. Preoperative planning for total hip arthroplasty. Quantitating its utility and precision. J Arthroplast. 1992;7 Suppl:403 9. 6. Maloney WJ, Keeney JA. Leg length discrepancy after total hip arthroplasty. J Arthroplast. 2004;19(4 Suppl 1):108 10. 7. Konyves A, Bannister GC. The importance of leg length discrepancy after total hip arthroplasty. J Bone Joint Surg Brit Vol. 2005;87(2):155 7.

Yang et al. BMC Surgery (2015) 15:29 Page 6 of 6 8. Xue E, Su Z, Chen C, Wong PK, Wen H, Zhang Y. An intraoperative device to restore femoral offset in total hip arthroplasty. J Orthop Surg Res. 2014;9:58. 9. Sarin VK, Pratt WR, Bradley GW. Accurate femur repositioning is critical during intraoperative total hip arthroplasty length and offset assessment. J Arthroplast. 2005;20(7):887 91. 10. Shiramizu K, Naito M, Shitama T, Nakamura Y, Shitama H. L-shaped caliper for limb length measurement during total hip arthroplasty. J Bone Joint Surg Brit Vol. 2004;86(7):966 9. 11. Rubash HE, Parvataneni HK. The pants too short, the leg too long: leg length inequality after THA. Orthopedics. 2007;30(9):764 5. Submit your next manuscript to BioMed Central and take full advantage of: Convenient online submission Thorough peer review No space constraints or color figure charges Immediate publication on acceptance Inclusion in PubMed, CAS, Scopus and Google Scholar Research which is freely available for redistribution Submit your manuscript at www.biomedcentral.com/submit