Semiflex 3D. Always perfectly oriented. 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry

Similar documents
Semiflex 3D. Always perfectly oriented. 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry

X-ray Dosimetry. True Precision. Superior accuracy and excellent resolution. Dosimetry Solutions for Diagnostic Radiology. Computer Tomography

Absolute Dosimetry. Versatile solid and water phantoms. Introduction Introduction Introduction Introtro Intro Intro

The Right Choice Any Day, Any Time. Product Solutions for LINAC QA. Overview

Practical Reference Dosimetry Course April 2015 PRDC Program, at a glance. Version 1.0. Day 1 Day 2 Day 3 Day 4

Calibration of dosimeters for small mega voltage photon fields at ARPANSA

Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties

DOSIMETRIC COMPARISION FOR RADIATION QUALITY IN HIGH ENERGY PHOTON BEAMS

Calibration of Radiation Instruments Used in Radiation Protection and Radiotherapy in Malaysia

EXPERIMENTAL RESULTS IN PERCENTAGE DEPTH DOSE (PDD) DETERMINATION AT THE EXTENDED DISTANCES *

Comparison of microlion liquid filled ionisation chamber with Semiflex and Pinpoint air filled chambers

Online Care, Online Control, Online Confidence

5th ADAMAS Workshop at GSI December 15-16, 2016, Darmstadt, Germany

STEREOTACTIC DOSE VERIFICATION PHANTOM VERSATILE STEREOTACTIC QA PHANTOMS

Hot Topics in SRS: Small Field Dosimetry & Other Treatment Uncertainties. Sonja Dieterich, PhD University of California Davis

Unrivaled, End-to-End

Ion recombination corrections of ionization chambers in flattening filter-free photon radiation

Assessment of a three-dimensional (3D) water scanning system for beam commissioning and measurements on a helical tomotherapy unit

Topics covered 7/21/2014. Radiation Dosimetry for Proton Therapy

On the impact of ICRU report 90 recommendations on k Q factors for high-energy photon beams

PMP. Use of Cylindrical Chambers as Substitutes for Parallel- Plate Chambers in Low-Energy Electron Dosimetry. Original Article.

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 4, NUMBER 4, FALL 2003

MAX-HD SRS PHANTOM THE COMPREHENSIVE END-TO-END SRS PHANTOM SCAN PLAN LOCALIZE TREAT. distributed by:

Blue Phantom 2 with OmniPro-Accept (V 7) Fastest, Most Accurate and Most Reliable Solution for Relative Dosimetry

Computed tomography Acceptance testing and dose measurements

Application(s) of Alanine

Radiochromic film dosimetry in water phantoms

Dosimetric characterization of surface applicators for use with the Xoft ebx system

ABSTRACTS FOR RADIOTHERAPY STANDARDS USERS MEETING. 5 th June 2007

Assessment of Dosimetric Functions of An Equinox 100 Telecobalt Machine

Detector comparison for small field output factor measurements with flattening filter free photon beams

Investigation of the clinical performance of a novel solid-state diagnostic dosimeter

ph fax

Delivery Quality Assurance with a High Resolution Liquid Filled Ion Chamber Array for Robotic Radiosurgery

LONG TERM STABILITY OF THE PERFORMANCE OF A CLINICAL LINEAR ACCELERATOR AND Z-SCORE ASSESSEMENT FOR ABSORBED DOSE TO WATER QUANTITY

A comparison of dose distributions measured with two types of radiochromic film dosimeter MD55 and EBT for proton beam of energy 175 MeV

IBA Dosimetry Company Presentation. Patient Safety & Quality Control

Applications of Monte Carlo simulations to radiation dosimetry

Plan-Specific Correction Factors for Small- Volume Ion Chamber Dosimetry in Modulated Treatments on a Varian Trilogy

Amendment No. 2. Item No. 2 (Rfx/ Event number )

S. Derreumaux (IRSN) Accidents in radiation therapy in France: causes, consequences and lessons learned

Measurements of Air Kerma Index in Computed Tomography: A comparison among methodologies

Comparative Study of Absorbed Doses in Different Phantom Materials and Fabrication of a Suitable Phantom

Efficient Dosimetry for Proton Therapy

Traceability and absorbed dose standards for small fields, IMRT and helical tomotherapy

INTRODUCTION. Material and Methods

Recent advances in dosimetry in reference conditions for proton and light-ion beams

Two-Dimensional Thermoluminescence Dosimetry System for Proton Beam Quality Assurance

D DAVID PUBLISHING. Uncertainties of in vivo Dosimetry Using Semiconductors. I. Introduction. 2. Methodology

Dosimetric study of 2D ion chamber array matrix for the modern radiotherapy treatment verification

SOMATOM Drive System Owner Manual Dosimetry and imaging performance report

Volumetric Modulated Arc Therapy - Patient Specific QA

SRS/SBRT Errors and Causes

Verification of Relative Output Factor (ROF) Measurement for Radiosurgery Small Photon Beams

Can we hit the target? Can we put the dose where we want it? Quality Assurance in Stereotactic Radiosurgery and Fractionated Stereotactic Radiotherapy

Application of international standards to diagnostic radiology dosimetry

TLD as a tool for remote verification of output for radiotherapy beams: 25 years of experience

MEASUREMENT OF THE EQUIVALENT INDIVIDUAL DOSES FOR PATIENTS IN ANGIOGRAPHY PROCEDURE AND INTERVENTIONAL RADIOLOGY WITH THERMOLUMINESCENT SYSTEMS

Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method

8/2/2017. Objectives. Disclosures. Clinical Implementation of an MR-Guided Treatment Unit

IGRT1 technologies. Paweł Kukołowicz Warsaw, Poland

Dosimetry and QA of proton and heavier ion beams

Università degli Studi di Napoli Federico II. Dipartimento di Fisica "Ettore Pancini"

Optimization of the T2 parametric image map calculation in MRI polymer gel dosimetry

8/2/2018. Disclosures. In ICRU91: SRT = {SBRT/SABR, SRS}

Activity report from JCOG physics group

Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry

AAPM s TG 51 Protocol for Clinical Reference Dosimetry of High-Energy Photon and Electron Beams

Toshiba Aquillion 64 CT Scanner. Phantom Center Periphery Center Periphery Center Periphery

IEC Subcommittee 62C (Equipment for Radiotherapy, Nuclear Medicine and Radiation Dosimetry): Recent and Active Projects

See it! Trust it! Treat it!

Active Scanning Beam 3 Checking Delivery/Dosimetry

Verification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging

Mania Aspradakis John Byrne Hugo Palmans John Conway Jim Warrington Karen Rosser Simon Duane

CHAPTER 5. STUDY OF ANGULAR RESPONSE OF asi 1000 EPID AND IMATRIXX 2-D ARRAY SYSTEM FOR IMRT PATIENT SPECIFIC QA

How accurately can we measure dose clinically? Accurate clinical dosimetry. Dosimetric accuracy requirement

A new geometric and mechanical verification device for medical LINACs

Can we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer?

Safety issues related to the Synchrotron Stereotactic Radiation Therapy project at the ESRF

Blue Phantom 2 with. Built for the next generation. Introduction Introduction Introduction Introtro Intro Intro

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

IAEA/WHO NETWORK OF SECONDARY STANDARD DOSIMETRY LABORATORIES

Diode calibration for dose determination in total body irradiation

Intensity modulation techniques for spinal treatments and on-line VolumeView TM guidance

Data Collected During Audits for Clinical Trials. July 21, 2010 Geoffrey S. Ibbott, Ph.D. and RPC Staff

NEW PERFORMANCE STANDARD: GAFCHROMIC FILM BASED DOSIMETRY SYSTEM. Xiang Yu and Andre Micke Advanced Materials Group Ashland Specialty Ingredients

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Dependence of the thermoluminescent high-temperature ratio (HTR) of LiF:Mg,Ti detectors on proton energy and dose

CURRENT CT DOSE METRICS: MAKING CTDI SIZE-SPECIFIC

ARCCHECK: COMPREHENSIVE EVALUATION OF THE DIODE ARRAY PHANTOM - RULES OF THUMB FOR PHANTOM USE FOR QA. By Vibha Chaswal, Ph.D.

A preliminary clinic dosimetry study for synchrotron radiation therapy at SSRF

IMRT QA: Point Dose Measurements or 2D Array?

Patient and Linac QA - present and the future

Development and prospects on dosimetry at radiotherapy levels in the Secondary Standard Dosimetry Laboratory of Cuba.

Small field diode dosimetry

Radiation Protection Services in R.Macedonia

Physics. Copyright 2010 Xoft, Inc.

RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY. L19: Optimization of Protection in Mammography

Establishment of the new IEC mammography qualities in a clinical system used for instruments calibration

Transcription:

DETECTORS Always perfectly oriented. Semiflex 3D 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry The New Reference Class Full 3D Geometry For FFF and FF Beams

Semiflex 3D 3D Detector Technology For better results. For faster scans. Semiflex 3D combines the advantages of a three-dimensional chamber design with advanced manufacturing technology. For Multiple Applications LINAC Acceptance Testing TPS Beam Data Commissioning Clinical Reference Dosimetry Point Dose Measurements Highlights As flexible as its name waterproof referenceclass thimble ionization chamber for relative and absolute dosimetry measurements in water, air or any solid state phantom Accurate measurements of standard and non-standard fields down to a field size of 2.5 cm x 2.5 cm True 3D geometry fast scanning in cross-plane and in-plane directions without tank rotation Vertical chamber holder with convenient stop thimble for quick detector setup and accurate, high-resolution scanning in axial orientation Small size, minimal volume averaging, high spatial resolution ideal for absolute dose measurement in small and FFF fields Exceptional dosimetric characteristics meets or exceeds all requirements of AAPM TG-51 and IEC 60731 Absolute dose calibration according to all major dosimetry protocols, such as IAEA TRS-398, AAPM TG-51, DIN 6800-2

Relative Dosimetry and Point Dose Measurements Flexible Orientation Semiflex 3D has been designed for axial and radial beam incidence, offering greater flexibility and helping to reduce positioning errors that might occur by repeated tank and detector setups. A vertical chamber holder with a convenient stop thimble makes it very easy to quickly mount Semiflex 3D Perfect for axial and radial profile measurements perpendicular to the radiation beam. Minimizing stem and cable effects, it allows high-resolution profile measurements in axial orientation. Detector setup can be easily changed from axial to radial orientation within a few seconds. Full 3D Geometry Uniform response in any direction With its true 3D geometry, which provides a high resolution independent of detector orientation, Semiflex 3D allows you to measure in-plane and cross-plane beam profiles much faster and more conveniently. Using Semiflex 3D, you no longer need to rotate the water tank or change the detector setup to achieve a uniform response, helping you to save setup time and eliminate potential positioning errors.

Clinical Reference Dosimetry in Small and FFF Fields Minimal Volume Averaging: Better than a PTW Farmer Illustration comparing estimated volume averaging correction factors (k Vol ) for different PTW ionization chambers calculated for 10 MV FFF at D max depth using the geometrical method of [Kawachi2008]. [Kawachi2008]: T. Kawachi et al., Reference dosimetry condition and beam quality correction factor for CyberKnife beam, Med. Phys. 35 (2008), 4591 Compared to a 0.6 cm³ PTW Farmer chamber typically used for absolute dose calibration, the small-size 0.07 cm³ Semiflex 3D has reduced volume averaging to a minimum, making it particularly suitable for high-resolution dose measurements in unflattened (FFF) beams. The New Reference Class Exceptional dosimetric characteristics outstanding accuracy Well engineered and reliably produced, Semiflex 3D has been designed to meet and exceed all requirements of a reference-class ionization chamber as defined in AAPM TG-51 and IEC 60731. Minimal polarity effect (< 0.4 % correction, < 0.5 % maximum variation) Extremely low volume effect (est. 0.05 % correction in FFF field) Excellent settling time (< 0.3 %) Very low post-irradiation leakage far below IEC 60731 requirements Significantly reduced cable effects (< 100 fc / (Gy * cm)) Minimal chamber-to-chamber variation reliable k Q and k S values

Specifications Semiflex 3D Type 31021 Detector type: Design: Measuring quantities: Reference radiation quality: Nominal sensitive volume: Reference point: Direction of incidence: Nominal response: Long-term stability: Vented cylindrical ionization chamber waterproof, fully guarded absorbed dose to water, air kerma, exposure 60Co 0.07 cm³ on chamber axis, 3.45 mm from chamber tip axial, radial 2 nc/gy 0.3 % over 2 years Chamber voltage: ± (50... 400) V useful range, ± 500 V max. Polarity effect: Photons ± 0.8 % Electrons ± 1 % Directional response: ± 0.5 % for rotation around chamber axis ±1 % for tilting of axis up to ± 70 Leakage current: Cable leakage: Wall of sensitive volume: Total wall area density: Dimension of sensitive volume: Central electrode: Build-up cap: ± 4 fa 100 fc/(gy cm) 0.57 mm PMMA, 1.19 g/cm³ 0.09 mm graphite, 1.85 g/cm³ 84 mg/cm² radius 2.4 mm, length 4.8 mm Al 99.98, diameter 0.8 mm PMMA, thickness 3 mm Ion collection efficiency at nominal voltage Ion collection time: 118 μs Max. dose rate: 99.5 % saturation 6.7 Gy/s 99.0 % saturation 13.4 Gy/s Max. dose per pulse: 99.5 % saturation 0.68 mgy 99.0 % saturation 1.42 mgy Radiation quality: 60Co... 50 MV photons (9... 45) MeV electrons Field size: (2.5 x 2.5) cm²... (40 x 40) cm² (3.0 x 3.0) cm²... (40 x 40) cm² 18 MV Temperature: (10... 40) C, (50... 104) F Humidity: (10... 80) %, max. 20 g/m³ Air pressure: (700... 1060) hpa Connecting system: BNT, TNC, M Options & Accessories T48012 90Sr Radioactive Check Device T48002.1.004 Semiflex 3D Chamber Holder for Check Device T41023.1.280 Adapter for PTW Water Phantom 41023 for horizontal beams T2967/U6 Acrylic PMMA Chamber Plate 30 cm x 30 cm T29672/U33 RW3 Chamber Plate 30 cm x 30 cm TRUFIX and TRUFIX BS Holders, Build-up caps, Chamber Plates for OCTAVIUS 4D and more upon request

HEALTH PHYSICS NUCLEAR MEDICINE DIAGNOSTIC RADIOLOGY RADIATION THERAPY Dosimetry Pioneers since 1922. It all started with a brilliant invention the revolutionary Hammer dosemeter in 1922. Ingenuity coupled with German engineering know-how shaped the company s history and led to innovative dosimetry solutions that later became an industry standard. Over the years, PTW has maintained its pioneering spirit, growing into a global market leader of dosimetry applications well known for its outstanding quality and precision. Today, PTW dosimetry is one of the first choices for healthcare professionals in radiation therapy, diagnostic radiology, nuclear medicine and health physics. For more information on PTW dosimetry products, visit www.ptw.de or contact your local PTW representative: Headquarters PTW-Freiburg Physikalisch-Technische Werkstätten Dr. Pychlau GmbH Tel. +49 761 49055-0 info@ptw.de www.ptw.de PTW-UK Ltd. Tel. +44 1476 577503 sales@ptw-uk.com www.ptw-uk.com PTW Dosimetría Iberia S. L. Tel. +34 96 346 2854 info@ptwdi.es www.ptwdi.es PTW-New York Corporation Tel. (1-516) 827 3181 ptw@ptwny.com www.ptwny.com PTW-Asia Pacific Ltd. Tel. +852 2369 9234 info@ptw-asiapacific.com www.ptw-asiapacific.com PTW-Beijing Ltd Tel. +86 10 6443 0746 info@ptw-beijing.com www.ptw-beijing.com PTW-France SARL Tel. +33 1 64 49 98 58 info@ptw-france.com www.ptw-france.com PTW-Latin America Tel. +55 21 2178 2188 info@ptw.com.br www.ptw.com.br PTW Dosimetry India Pvt. Ltd. Tel. +91 44 42079999 info@ptw-india.in www.ptw-india.in PTW. All data subject to change without prior notice. PTW Farmer, TRUFIX and OCTAVIUS are registered trademarks of PTW. All other trademarks mentioned in this document are the property of their respective owners. D252.139.06/01 2017-05 Knowing what responsibility means