In keeping with the Scottish Diabetes Group criteria, use should be restricted to those who:

Similar documents
NHS GG&C Introduction of Freestyle Libre flash glucose monitoring system

Commissioning Statement. Flash Glucose Monitoring system (FreeStyle Libre ) March 2018

Placename CCG. Policies for the Commissioning of Healthcare

Description of the technology

THE SHEFFIELD AREA PRESCRIBING GROUP. Position Statement for Prescribing of Freestyle Libre In Type 1 Diabetes. Date: March 2018.

Commissioning Statement

Flash Glucose Monitoring (Flash GM) Frequently asked questions (November 2018)

In response to an enquiry from the Scottish Diabetes Group (SDG)

Policy for Continuous Glucose Monitoring for Type 1 Diabetic Paediatric Patients (<18 years of age)

NHS Leeds CCG. Policy for the Funding of Flash Glucose Monitoring (FlashGM) in Paediatrics and Adults

Policy for the Provision of Continuous Glucose Monitoring and Flash Glucose Monitoring to patients with Diabetes Mellitus

FreeStyle Libre for glucose monitoring: Interim Position Statement for GPs & Patient FAQ

DERBYSHIRE JOINT AREA PRESCRIBING COMMITTEE (JAPC) JAPC Briefing FreeStyle Libre

medicines_management/correspondence/pathway-for-the-managed- Access-of-FreeStyle-Libre.

Implementation of Freestyle Libre prescribing guidance across the NHS in London

NHSScotland is required to consider the Scottish Health Technologies Group (SHTG) advice.

Advice Statement 005/18 April 2018

Commissioning Policy

Advice Statement. Advice Statement November Advice for NHSScotland. Why is SHTG looking at this topic?

Policy for the Provision of Insulin Pumps for Patients with Diabetes Mellitus

Audit support for continuous subcutaneous insulin infusion for the treatment of diabetes mellitus (review of technology appraisal guidance 57)

Scottish Medicines Consortium

Technology appraisal guidance Published: 26 October 2016 nice.org.uk/guidance/ta416

Technology appraisal guidance Published: 26 July 2017 nice.org.uk/guidance/ta459

Scottish Medicines Consortium

How can I access flash glucose monitoring if I need it? Support pack. This pack will help you to find out more about flash and how you can access it.

Technology appraisal guidance Published: 26 April 2017 nice.org.uk/guidance/ta442

COPYRIGHTED MATERIAL. Chapter 1 An Introduction to Insulin Pump Therapy WHAT IS INSULIN PUMP THERAPY?

PUBLIC PETITIONS COMMITTEE AGENDA. 2nd Meeting, 2019 (Session 5) Thursday 24 January 2019

Technology appraisal guidance Published: 26 September 2012 nice.org.uk/guidance/ta264

Technology appraisal guidance Published: 21 February 2018 nice.org.uk/guidance/ta507

Technology appraisal guidance Published: 24 January 2018 nice.org.uk/guidance/ta499

Scottish Health Technologies Group

Placename CCG. Policies for the Commissioning of Healthcare

National Diabetes Treatment and Care Programme

Outcomes assessed in the review The outcomes assessed in the review and used as model inputs were the incident rates of:

Diabetes UK Consensus Guideline for Flash Glucose Monitoring

rosuvastatin, 5mg, 10mg, 20mg, film-coated tablets (Crestor ) SMC No. (725/11) AstraZeneca UK Ltd.

1. Comparative effectiveness of liraglutide

Networking for success: A burning platform in Berkshire West

Putting NICE guidance into practice. Resource impact report: Hearing loss in adults: assessment and management (NG98)

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE GUIDANCE EXECUTIVE (GE)

KEY QUESTIONS What outcome do you want to achieve for mental health in Scotland? What specific steps can be taken to achieve change?

Diagnostics guidance Published: 12 February 2016 nice.org.uk/guidance/dg21

insulin degludec (Tresiba ) is not recommended for use within NHS Scotland.

Access to newly licensed medicines. Scottish Medicines Consortium

Expectation of Care. for Persons with Type 1 Diabetes. NHS Greater Glasgow & Clyde. Managed Clinical Network for Diabetes

QOF Indicator DM013:

Healthcare professionals involved in care of children and young people with Type 1 Diabetes Mellitus. Children and young people with diabetes mellitus

Healthcare professionals involved in care of children and young people with Type 1 Diabetes Mellitus

Agenda Item 10 - Glucose Monitoring Device for Individuals with Diabetes

Measuring outcomes to improve the management of continence care. Dr Adrienne Rivlin KPMG Global Strategy Group

Technology appraisal guidance Published: 28 September 2016 nice.org.uk/guidance/ta411

Technology appraisal guidance Published: 23 November 2016 nice.org.uk/guidance/ta418

Technology appraisal guidance Published: 8 November 2017 nice.org.uk/guidance/ta487

Sandwell & West Birmingham integrated community care diabetes model (DICE) the future of diabetes services?

Scottish Medicines Consortium

DMEP Study Section 1 1

Referral to Adult Diabetes Specialist Services

Townsville Broadband Diabetes Telehealth Trial EVALUATION REPORT. May 2015

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE. Health Technology Appraisal

Shaping Diabetes Services in Southern Derbyshire. A vision for Diabetes Services For Southern Derbyshire CCG

The management of diabetes

Technology appraisal guidance Published: 30 August 2017 nice.org.uk/guidance/ta471

Technology appraisal guidance Published: 7 February 2018 nice.org.uk/guidance/ta505

Process for appraising orphan and ultra-orphan medicines and medicines developed specifically for rare diseases Effective from September 2015

Technology appraisal guidance Published: 28 November 2012 nice.org.uk/guidance/ta267

Process for End of Life and Very Rare Conditions (orphan and ultra-orphan medicines)

Guidance on the Self-Monitoring of Blood Glucose in Adults with Diabetes

Technology appraisal guidance Published: 28 June 2017 nice.org.uk/guidance/ta448

DIABETES BLOOD GLUCOSE MONITORING AT HOME (ADULTS)

Peginterferon alfa and ribavirin for the treatment of chronic hepatitis C. Part review of NICE technology appraisal guidance 75 and 106

Dear Colleague. DL (2017) June Additional Funding for CGMs and Adult Insulin Pumps Summary

Technology appraisal guidance Published: 15 December 2010 nice.org.uk/guidance/ta211

Technology appraisal guidance Published: 11 October 2017 nice.org.uk/guidance/ta480

DIABETES BLOOD GLUCOSE MONITORING AT HOME (ADULTS)

Diabetes Subcommittee of PTAC meeting held 3 March (minutes for web publishing)

Technology appraisal guidance Published: 22 September 2010 nice.org.uk/guidance/ta200

Implementation of Flash Glucose Monitoring

Management of diabetes

Health technology assessment report in support of county council decisionmaking

BRISTOL-MYERS SQUIBB and ASTRAZENECA v SANOFI

Integrated Diabetes Care in Oxfordshire -patient's perspective. Avril Surridge

Technology appraisal guidance Published: 18 April 2018 nice.org.uk/guidance/ta518

June 2016 Review: June 2019

Botulinum toxin type A for the prevention of headaches in adults with chronic migraine

dulaglutide 0.75mg and 1.5mg solution for injection in pre-filled pen (Trulicity ) SMC No. (1110/15) Eli Lilly and Company Ltd.

Background Comparative effectiveness of nivolumab

Technology appraisal guidance Published: 28 March 2018 nice.org.uk/guidance/ta516

GDm-Health is free to download and use. Its use may result in efficiency savings from reducing face-to-face clinic appointments.

Technology appraisal guidance Published: 25 January 2017 nice.org.uk/guidance/ta431

Community alcohol detoxification in primary care

GUIDELINE FOR SELF MONITORING OF BLOOD GLUCOSE IN ADULTS WITH DIABETES

National Diabetes Inpatient Audit (NaDIA) 2016

Technology appraisal guidance Published: 18 July 2018 nice.org.uk/guidance/ta531

Scottish Medicines Consortium

Transcription:

Advice Statement 009-18 July 2018 Advice Statement What is the clinical and cost effectiveness of Freestyle Libre flash glucose monitoring for patients with diabetes mellitus treated with intensive insulin therapy? Advice for NHSScotland It is recommended that flash glucose monitoring with Freestyle Libre is available for individuals with diabetes who are actively engaged in the management of their diabetes and who intensively manage their condition with multiple daily insulin injections or insulin pump therapy. In keeping with the Scottish Diabetes Group criteria, use should be restricted to those who: Agree to attend a locally provided flash glucose monitoring education session; Agree to scan glucose levels no fewer than six times per day; Satisfy their clinical team that they (or carer) have the required knowledge/skills to self-manage diabetes; for example, having attended a recognised diabetes structured education programme. Clinical review timescales should be agreed to ensure that use of the device continues to support individuals diabetes care management. NHS Boards should consider the continuation and discontinuation criteria contained within the Managed Clinical Network (MCN) leads interim position statement (see Annex 1). Recipients should be encouraged to share data with their care team to facilitate clinical review and to contribute to local and national audit. NHSScotland is required to consider the Scottish Health Technologies Group (SHTG) advice. File name: 20180601FSL AS v1 0 Date: 12 July 2018 Page: 1

Why is SHTG looking at this topic? Diabetes mellitus is a major cause of morbidity and mortality in Scotland with around 300,000 people diagnosed with the condition. Freestyle Libre is a flash glucose monitoring system. The topic was prioritised for inclusion on the SHTG work programme following a referral from the Scottish Diabetes Group. An extended Evidence Note 81 was produced by Healthcare Improvement Scotland in response to this request. The extended Evidence Note was based on a EUnetHTA rapid review of published clinical effectiveness and safety literature, but also incorporated a range of additional evidence sources including: A Healthcare Improvement Scotland economic evaluation A patient group submission from Diabetes Scotland NHSScotland clinical expert input. Background Self-monitoring of glucose levels is essential for people with type 1 (T1) diabetes mellitus (DM), and is necessary for approximately 10% of people with type 2 (T2) DM to manage glycaemic control and adjust insulin or other medications. Currently, finger-prick selfmonitoring of blood glucose (SMBG) using test strips and blood glucose meters is the most frequently used monitoring method. The recommended number of tests ranges from four to 10 per day depending on the type of diabetes and the required intensity of monitoring. Freestyle Libre is a flash glucose monitoring system which has two main parts: a handheld reader, and a disposable sensor which patients wear on their body. The sensor, which lasts up to 14 days, has a filament which measures glucose levels in the interstitial fluid. Patients use the reader or a mobile phone app to wirelessly scan the sensor and obtain their glucose readings. The Freestyle Libre flash glucose monitoring system is indicated for measuring interstitial fluid glucose levels in people (aged 4 and above) with diabetes mellitus, including pregnant women. A key feature of the technology is the display of long term glucose variability and trends, rather than a series of static measurements. Freestyle Libre is not intended to completely replace SMBG, but offers an alternative monitoring approach. SMBG will still be required under certain circumstances such as where glucose levels are changing rapidly or where readings are not consistent with symptoms being experienced. Also, SMBG is required to meet current driving license requirements. Freestyle Libre is not indicated for patients whose condition requires continuous monitoring of blood glucose. File name: 20180601FSL AS v1 0 Date: 12 July 2018 Page: 2

Clinical effectiveness In two randomised controlled trials (RCTs), use of Freestyle Libre by adults with wellcontrolled T1 DM (n=241) or by people with poorly controlled T2 DM (n=224) reduced time in hypoglycaemia and hypoglycaemic events at six months when compared with standard SMBG. These reductions were statistically significant. Time in hypoglycaemia and hypoglycaemic events were defined using a surrogate endpoint of sensor glucose readings less than 3.9mmol/L (70mg/dL). The RCTs also reported that: o For people with well-controlled T1 DM, glycaemic control (as measured by HbA1c) was not statistically significantly different between study arms. o In a subgroup analysis, of people with poorly-controlled T2 DM aged under 65 years (n=142), glycaemic control (HbA1c) significantly improved in those using Freestyle Libre compared with those using SMBG; there was a statistically significant reduction in HbA1c. The effect was absent when data from participants of all ages were considered. o When compared with SMBG, Freestyle Libre improved treatment satisfaction as measured by the Diabetes Treatment Satisfaction Questionnaire (DTSQ). No statistically significant difference between the study groups was found in the Diabetes Distress Scale (DDS) score or overall Diabetes Quality of Life Questionnaire (DQoL) score. Methodological weaknesses mean that RCT findings may be considered at risk of bias. Safety The proportion of participants in the two RCTs experiencing serious adverse events was similar between those using SMBG and Freestyle Libre. In the two RCTs and in two small observational studies (n=72, n=89) sensor site symptoms were commonly reported by Freestyle Libre users. In the RCT in people with T1 DM 39% of people using the device reported at least one sensor site symptom. Both RCTs excluded participants with known allergy to medical grade adhesives. Cost effectiveness A small number of published cost analyses and cost effectiveness analyses indicated that Freestyle Libre may be cost-effective in people with T1 and T2 DM treated with intensive insulin and self-monitoring their blood glucose levels. However, a lack of transparency and generalisability to the Scottish setting meant that no conclusions could be drawn from the published literature. A Healthcare Improvement Scotland economic evaluation was carried out to model the impact of Freestyle Libre on costs and benefits compared with SMBG. The results indicate that Freestyle Libre is likely to be cost effective for people treated with File name: 20180601FSL AS v1 0 Date: 12 July 2018 Page: 3

intensive insulin therapy in both the T1 and T2 DM populations, with incremental cost effectiveness ratios (ICERs) falling within commonly accepted willingness-to-pay thresholds. The ICER for Freestyle Libre compared with SMBG ranged from 2,459 to 12,340 per quality-adjusted life year (QALY) in T1 DM and from 4,498 to 18,125 in T2 DM, depending on the modelling approach used. One-way sensitivity analyses indicated Freestyle Libre was still likely to be costeffective under a wide range of scenarios and cost saving against SMBG when a mean number of eight blood glucose tests per day was assumed. Probabilistic sensitivity analysis also indicated a high probability of Freestyle Libre being cost-effective. The following uncertainties should be considered when interpreting the results: heterogeneity associated with the evidence sources used within the economic evaluation; use of a surrogate measure from the RCTs for real-life symptomatic hypoglycaemic events; methods used to capture utility gain and patient preference associated with the device. Further details are provided within the extended Evidence Note. Longer term data are not currently available to inform comprehensive modelling of long term treatment effects. In the T2 DM population there is greater uncertainty surrounding the cost effectiveness conclusions. Assuming an uptake rate of 30% in year 1 rising to 50% by year 5, the budget impact of Freestyle Libre in NHSScotland was estimated to be 3.3m in year 1 rising to 6.8m by year 5 in the T1 DM population and 5.5m rising to 11.4m in the T2 DM population. This increase was attributed to the incremental cost of monitoring of 370 per T1 DM patient and 544 per T2 DM patient. These figures do not include the potential resource savings to the NHS linked to the decreased frequency of severe hypoglycaemia requiring medical assistance resulting from Freestyle Libre use. Patient and social aspects A patient organisation submission was received from Diabetes Scotland that collated information from a UK patient survey, focus group findings and experiences of use of Freestyle Libre as reported by users of their helpline and online forum. The following key points emerged: People with experience of using Freestyle Libre have reported improved quality of life, as it allows them to carry on their daily lives with greater ease and confidence. This helps reduce the stress and anxiety of managing diabetes and has a beneficial impact both for the patient and for the wider network of family and carers. Using Freestyle Libre may particularly benefit people in jobs where regular fingerprick testing is not always practical. File name: 20180601FSL AS v1 0 Date: 12 July 2018 Page: 4

Respondents suggest that use of Freestyle Libre, by supporting more effective selfmanagement of diabetes, may lead to a reduced risk of longer-term serious health complications and associated treatment costs. Context (includes organisational issues) Freestyle Libre received regulatory approval in September 2014 and was initially available for use in seven European countries including for private purchase in the UK. Freestyle Libre was added to the Scottish Drug Tariff on 1st November 2017. As of May 2018, seven out of 14 health boards in Scotland are awaiting this SHTG advice, while the remaining seven already have pathways and/or prescribing policies in place for Freestyle Libre although there is variation across the pathways. SHTG advice is intended to contribute to increased consistency in availability across Scotland; reducing the risk of inequity of access from both a geographical perspective and individuals ability to self-fund. The Driving and Vehicle Licensing Agency (DVLA) currently stipulates that drivers must monitor their blood glucose levels, with test strips and a meter, within two hours of driving and every two hours while driving. It is anticipated that revised regulations for drivers with diabetes will reflect technological advances in glucose measurement and that devices suitably assessed and endorsed by medical experts may, in future, be recognised as fit for purpose. SCI Diabetes a shared electronic patient record to support treatment of NHSScotland patients with diabetes provides a mechanism through which patient data can be provided for national and local audit programmes to support the ongoing assessment of treatment options for patients with diabetes. Further research There is currently a lack of data relating to use of Freestyle Libre in children or young people with diabetes. Further research utilising real-world data collected within SCI Diabetes is encouraged and could be used to inform ongoing clinical and economic assessment and future decision-making surrounding the use of the device. Further comparative studies using cohorts more representative of the Scottish population are encouraged to help determine the effect of Freestyle Libre on glycaemic control. Long-term outcome studies are needed to inform the impact of Freestyle Libre on long-term complications of diabetes. Two ongoing RCTs were identified comparing the use of Freestyle Libre with SMBG: NCT02776007, NCT03522870 Current evidence on Freestyle Libre appears to be at assessment or long term study stage of the IDEAL-D framework. File name: 20180601FSL AS v1 0 Date: 12 July 2018 Page: 5

Advice context: No part of this advice may be used without the whole of the advice being quoted in full. This advice represents the view of the SHTG at the date noted. It is provided to inform NHS boards in Scotland when determining the place of health technologies for local use. The content of this Advice Statement was based upon the evidence and factors available at the time of publication. An international evidence base is reviewed and thus its generalisability to NHSScotland should be considered by those using this advice to plan services. It is acknowledged that the evidence constitutes only one of the sources needed for decision making and planning in NHSScotland. Readers are asked to consider that new trials and technologies may have emerged since first publication and the evidence presented may no longer be current. This advice does not override the individual responsibility of health professionals to make decisions in the exercise of their clinical judgment in the circumstances of the individual patient, in consultation with the patient and/or guardian or carer. SHTG Advice Statements will be considered for review if new evidence becomes available which is likely to materially change the advice. Stakeholders may submit a request, highlighting new evidence to shtg.hcis@nhs.net Chair Scottish Health Technologies Group NICE has accredited the process used by Healthcare Improvement Scotland to produce its evidence review products. Accreditation is valid for 5 years from January 2013. More information on accreditation can be viewed at www.nice.org.uk/accreditation File name: 20180601FSL AS v1 0 Date: 12 July 2018 Page: 6

Annex 1 Use of Freestyle Libre flash glucose monitoring system Diabetes Managed Clinical Network Lead Clinicians Position Statement January 2018 Recommendations for Continuation. The specialist clinician should recommend ongoing use of FSL, based on evidence of continued benefit obtained as part of routine clinical review (6 monthly) within secondary care. Each patient would need to demonstrate benefit in one or more of the following over a 12 month period: 1. Continuation Criteria Reduction in episodes of DKA. Reduction in admissions to hospital. Reduction in episodes of severe hypoglycaemia. Reduction in the proportion of time spent in hypoglycaemia. Reversal of impaired awareness of hypoglycaemia. Improvement in HbA1c of 5 mmol/mol in 6 months. 2. Discontinuation Criteria any one of the following: Failure to achieve at least one of the criteria listed in the section above. Failure to attend follow up appointments. Failure to scan at least six times per day. Failure to share this data with their secondary care team. Failure to engage with secondary care team to optimise issues with glycaemic control. Failure to use testing strips and sensors as recommended. Evidence of greater harm than benefit on clinical and psychological health (eg increased frequency of hypos, increased psychological morbidity). File name: 20180601FSL AS v1 0 Date: 12 July 2018 Page: 7