Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079

Similar documents
Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188E

Simultaneous Analysis of Active Pharmaceutical Ingredients and Their Counter-Ions Using a Mixed-Mode Column

Determination of Amantadine Residues in Chicken by LCMS-8040

Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids

Comparison of a UPLC Method across Multiple UHPLC Systems

ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS

Application Note. Small Molecule Pharmaceuticals. 2-Ethyl-2-phenylmalonamide Ethosuximide Primidone Carbamazepine. Carbamazepine-

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Evaluation of UHPLC System Performance Under High Throughput Conditions. William Hedgepeth, Masatoshi Takahashi, Shimadzu Scientific Instruments

Analysis of Common Sweeteners and Additives in Beverages with the PerkinElmer Flexar FX-15 System Equipped with a PDA Detector

Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system

Vitamin D3 and related compounds by ESI and APCI

Impurity Profiling of Carbamazepine by HPLC/UV

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

Qualitative and quantitative determination of phenolic antioxidant compounds in red wine and fruit juice with the Agilent 1290 Infinity 2D-LC Solution

Designer Cannabinoids

QuickSplitTM Flow Splitters

Liquid Chromatograph Mass Spectrometer LCMS-8050 C146-E232A

Application Note. Agilent Application Solution Analysis of fat-soluble vitamins from food matrix for nutrition labeling. Abstract.

Analysis of Isoflavones with the PerkinElmer Flexar FX-15 UHPLC System Equipped with a PDA Detector

Rapid Screening and Quantitation of Pesticide Residues in Cannabis by Modified QuEChERS and LC-MS-MS

F. Al-Rimawi* Faculty of Science and Technology, Al-Quds University, P.O. Box 20002, East Jerusalem. Abstract

2D-LC as an Automated Desalting Tool for MSD Analysis

Automated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Agilent 1220 Infinity LC System Performance Specifications

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column

Agilent 1260 Infinity Analytical SFC System

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ

HPLC Analysis with Fluorescence Detection of Chlorophyll Degradation Products Pheophytins and Pyropheophytin in Virgin Olive Oil

Quantitative Analysis of Carbohydrates and Artificial Sweeteners in Food Samples Using GFC- MS with APCI Interface and Post-column Reagent Addition

Fully automated sensitive determination of immunosuppressant drugs in whole blood, using high quality internal standardization

High Throughput simultaneous analysis of 39 amino acids in various foods without derivatization using LC-MS/MS

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system

Edgar Naegele. Abstract

USP purity analysis of pravastatin sodium using the Agilent 1120 Compact LC

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

vii LIST OF TABLES TABLE NO DESCRIPTION PAGE 1.1 System Suitability Parameters and Recommendations Acidic and Alkaline Hydrolysis 15

Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection INTRODUCTION

Introduction to the Oligo HTCS Systems. Novatia, LLC

ACE C18-AR Use the Power!

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific

Chiral Multicolumn Method Development on the Agilent 1260 Infinity II SFC System

Increasing resolution using longer columns while maintaining analysis time Advantages of the wide power range of the Agilent 1290 Infinity LC System

Doubling the throughput of long chromatographic methods by using a novel Dual LC workflow

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

Identification & Confirmation of Structurally Related Degradation Products of Simvastatin

High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System

Sanjog Ramdharane 1, Dr. Vinay Gaitonde 2

Small Scale Preparative Isolation of Corticosteroid Degradation Products Using Mass-Based Fraction Collection Application

Liquid Chromatograph Mass Spectrometer LCMS-8060 C146-E286

Characterization of products formed by forced degradation of Etodoalc using LC/MS/MS

Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation

Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Analysis of HMF by HPLC

Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column

Rapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

AS Application Note 1602

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit

LCMS Vitamin D3 Method development

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

Performance characteristics of the Agilent 1100 Series preparative pump. Technical Note. Abstract

GlycanPac AXH-1 Columns

Sue D Antonio Application Chemist Cedar Creek, TX

Analysis of Counterfeit Antidiabetic Drugs by UHPLC with the Agilent 1220 Infinity Mobile LC

Quantitative analysis of hydrophilic metabolite using ion-paring chromatography with a high-speed triple quadrupole mass spectrometer

Qualitative and quantitative determination of cannabinoid profiles and potency in CBD hemp oil using LC/UV and Mass Selective Detection

Am I getting the very best value from my UHPLC analyses?

Maximizing Efficiency Using Agilent InfinityLab Poroshell 120 Columns

Ankit et al Journal of Drug Delivery & Therapeutics; 2013, 3(2), Available online at RESEARCH ARTICLE

[Application Note] TOXICOLOGY SCREENING BY UPLC/PDA IN COMBINATION WITH AN EXTENSIVE COMPOUND LIBRARY

Chromatography Vacuum Ultraviolet Spectroscopy

Dr. Erin E. Chambers Waters Corporation. Presented by Dr. Diego Rodriguez Cabaleiro Waters Europe Waters Corporation 1

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

A Novel Platform of On-line Sample Pre-treatment and LC/MS/MS Analysis for Screening and Quantitation of Illicit Drugs in Urine

Analysis of Antioxidants in Vegetable Oils Using the Agilent 1260 Infinity Hybrid SFC/UHPLC System with MS Detection

Application Note. Introduction

Analysis of bisphenol A leaching from baby feeding bottles

Profiling of Endogenous Metabolites Using Time-of-Flight LC/MS with Ion Pair Reverse Phase Chromatography

Cannabis Testing Laboratory Solutions

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

Simultaneous determination of triacetin, acetic ether, butyl acetate and amorolfine hydrochloride in amorolfine liniment by HPLC

Application Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix

Analysis of Cannabinoids in Cannabis by UHPLC Using PDA Detection

Shimadzu s Guide to Vial Selection. Not all vials are the same

More structural information with MS n

Performance Characteristics of the Agilent 1290 Infinity II Multicolumn Thermostat

PTM Discovery Method for Automated Identification and Sequencing of Phosphopeptides Using the Q TRAP LC/MS/MS System

Transcription:

Ultra High Performance Liquid Chromatograph Nexera X2 C196-E79

Maximizing the Potential of UHPLC/HPLC Analyses Intelligence Intelligent data solutions, including a new i -PDeA peak calculation method for enhanced separation power, accelerate workflows. Sensitivity The ultimate platform for high-sensitivity UHPLC and HPLC detection. Resolution Enhanced peak resolution achieved by minimizing external column dispersion. Stability Superior stability for UHPLC/HPLC analyses. Ul tra H ig h P e r for mance Liquid Chr oma to g ra p h

Utilizing patented technologies, and driven by customer input, Shimadzu has developed the Nexera X2 series to deliver superior, real-world performance across a wider application range, while delivering unparalleled flexibility and reliability in UHPLC/HPLC analyses. With no limits and no compromises, the Nexera X2 achieves a new milestone in the evolution of liquid chromatography.

Nexera X2 Series A full range of configurations to meet your applications needs Nexera SR system features superior sensitivity, resolution and stability. i-pdea* offers new separation technology. Nexera UHPLC/HPLC system enables switching from UHPLC to HPLC in a single system using a selection of mixers and columns. *Intelligent Peak Deconvolution Analysis Nexera Quaternary system is a flexible quaternary gradient system that is HPLC and UHPLC compatible. Nexera Method Scouting system offers comprehensive method development using 96 combinations of mobile phases and columns. Nexera MP system is an LC/MS frontend HPLC for high-throughput analysis of multiple samples. Nexera TQ system and Nexera SQ system offers ultrafast LC/MS and LC/MS/MS analysis. 4

Nexera X2 Component The CBM-2A enables system control via a network. The CBM-2A allows for various system configuration to meet different laboratory workflows. CBM-2A Detector SPD-M3A Ultra-high-sensitivity and high-resolution detector The SPD-M3A realizes ultra-high sensitivity and minimized dispersion, supporting the new separation calculation method, i-pdea. The temperature-controlled optics provide stable baseline for genuine UHPLC analysis. *Intelligent Peak Deconvolution Analysis Column oven CTO-3A Features control to a maximum 15 C (Max column length: 15 mm) CTO-2AC Large space for placing multiple columns and valves (Max column length: 3 mm) CTO-3AS Compact column oven for LC/MS front end (Max column length: 5 mm) Autosampler SIL-3AC Multifunctional autosampler; pretreatment and loop injection are available SIL-3AC / Rack Changer II Maximum 12 plates can be set with this combination SIL-3ACMP Open-access autosampler with maximum 6 plates Solvent delivery unit Upgradable to binary gradient and quaternary gradient, the LC-3AD also supports solvent blending for automated mobile phase preparation. LC-3AD Ultra High Performance Liquid Chromatograph 5

Intelligence in UHPLC/HPLC Analysis Complete Separation of Co-eluted Peaks by Intelligent Peak Deconvolution Analysis ( i-pdea) i-pdea enables the extraction of a single peak from co-eluted peaks by utilizing difference in spectra by a few steps. The new separation method removes discussion of integration methods for co-eluted peaks. The i-pdea also helps detect impurity peaks in a target peak. Step 1 Analysis Step 2 Extraction of single peak signal using the difference between each spectrum Step 3 Display of single component representative peak Component B AU Component A Component B 1 2 Component A 1 2 nm shows 1 extraction of component B. shows 2 extraction of component A. Baseline separation Vertical separation Removes peak integration ambiguities Example1: Remove tailing peak Tailing peak.5 mg/l spiked.488 mg/l measured (98% accuracy) Target peak i-pdea..25.5.75 1. 1.25 min The target peak is on the tailing peak..25.5.75 1. 1.25 min Remove the tailing peak!! Example2: Impurity peak extracted from co-eluted peak Peak purity curve i-pdea.22.24.26.28 min This peak looks a single peak..22.24.26.28 min By removing the main peak, the impurity peak appears on the chromatogram!! 6

Ultimate Sensitivity Achieving maximum sensitivity The SPD-M3A photodiode array detector adopts the high-sensitivity and low-dispersion capillary cell, SR-Cell, which achieves a.4 1-5 AU noise level. The SPD-M3A offers ultimate in UHPLC analysis, realizing high-sensitivity and high-resolution. High-sensitivity and high-resolution SR-Cell Section of capillary cell The SR-Cell features high-sensitivity and low-dispersion by adopting total reflection capillary cell. mau 175 μau Main peak 125 6 4 S/N 9.53 2 75 5.5 7.7 9.9 min Impurity peak 25..5 1. min Column Shim-pack XR-ODS (5 mml. 2. mmi.d., 1.6 μm).6 ml/min Main peak propyl 4-hydroxybenzoate.5 Impurity peak ethyl 4-hydroxybenzoate The excellent sensitivity and wide dynamic detection range enables simultaneous analysis of a main ingredient and impurity of.5% content. Column Time program Shim-pack VP-ODS (15 mml. 4.6 mmi.d., 4.6 μm) 2% ( min)1% (3 min) 1. ml/min. 5. 1. 15. 2. 25. min Column Time program Shim-pack XR-ODS (75 mml. 3. mmi.d., 2.2 μm) 2% ( min)1% (4.2 min) 1.3 ml/min. 1. 2. 3. 4. min The SR-Cell is available for UHPLC and HPLC, realizing high-sensitivity analysis across a wide analytical range. Ultra High Performance Liquid Chromatograph 7

Maximized Resolution Superior peak shape for maximum peak resolution In ultrafast analysis, external column dispersion affects peak resolution. The SR-Cell in the SPD-M3A has minimized the cell volume to realize excellent peak shape with higher peak resolution, supporting genuine UHPLC analysis. peak 1 peak 2 peak 3 Column Shim-pack XR-ODS III (5 mml. 2. mmi.d., 1.6 μm).6 ml/min Tailing factor (Tf5%) Peak No. Nexera X2 Vendor A Vendor A UHPLC 1 2 1.39 1.297 1.546 1.486 Nexera X2 3 1.273 1.432.2.25.3.35.4.45.5 min Superior spectrum resolution and linearity The SPD-M3A provides unrivaled spectrum resolution by adopting an optimized optic system. In addition, the new signal treatment technology realizes excellent spectrum linearity across a wide area from low concentration to high concentration. The SPD-M3A supports analyses, such as purity analysis, that require a wide dynamic range. B/A=2.9 AU Caffeine 1 mg/l Caffeine 1 mg/l B Similarity.9998 A 23 24 25 26 27 28 nm A Benzene spectrum is often used for evaluation of spectrum resolution. The SPD-M3A shows world s highest spectrum resolution, B/A=2.9*. 25 3 35 nm (Normalize) The SPD-M3A shows excellent spectrum linearity in the analysis of caffeine samples with different concentrations. Nexera SR system for high-sensitivity and high-resolution Nexera SR system is configured with the new SPD-M3A photodiode array detector. The new peak calculation technology, i-pdea, proposes a new approach for separation of co-eluted peaks and extraction of impurity peaks from main peaks. The superior sensitivity and resolution expand the range of UHPLC analyses. *As of November 212, according to Shimadzu research. Nexera SR system 8

Unrivaled Stability Baseline stabilization by temperature-controlled TC-Optics The SPD-M3A adopts the new temperature-controlled TC-Optics with the SR-Cell that has an optimized heat exchange inlet pipe. These features achieve faster stabilization times low external dispersion for UHPLC analysis. The faster stabilization shortens the wait time for analysis, thereby increasing total analytical throughput. mau 1 SPD-M3A Mobile phase.5 ml/min Methanol Detector PDA 254 nm -1 Temperature RT -2-3 -4 Vendor A PDA detector 1 2 3 4 5 min The SPD-M3A shows a stable baseline faster after startup while the detector from vendor A shows baseline drift during 1 hour. SPD-M3A Stable performance against room temperature shift The SPD-M3A incorporates TC-Optics to achieve a more stable baseline against room temperature shifts. mau 25 254 nm.5 ml/min 2 15 Room temperature 3 C Mobile phase Detector Methanol UV 254 nm 1 5 SPD-M3A 25 C -5-1 -15 Vendor A PDA detector -2 1 2 3 4 5 6 min Ultra High Performance Liquid Chromatograph 9

Ultimate Flexibility Automation of mobile phase preparation by solvent blending function The modular nature of Nexera X2 allows a solvent blending function that can mix solvents according to desired ratios. This function enables dilution of solvent, buffer preparation and modifier addition for mobile phase preparation. 85% 1% 5% % A B C D Pump1 5% A 2% 5% B C 25% D Pump2 Solvent Blending Automated mobile phase preparation Binary Gradient Gradient elution by prepared solvents Buffer ph can be optimized using the solvent blending function as shown to the right chromatograms. The function is a useful tool for optimizing mobile phase conditions in method development. Blending 1 1, 2, 3 A / B = 6 / 4 ph 3. Blending 2 2 3 A / B = 2 / 8 ph 7.2 1, Benzoic acid 2, Sorbic acid 3, methyl 4-hydroxybenzoate 1. 1. 2. 3. 4. min. 1. 2. 3. 4. min Measured ph of mobile phase prepared by solvent blending Solvent blending Blending 1 3.1 Blending 2 7.192 Manual preparation 3.4 7.191 Pump X solvent Blending 1 A / B = 6 / 4 Blending 2 A / B = 2 / 8 A; 2 mmol/l phosphoric acid aqueous solution B; 2 mmol/l disodium hydrogen-phosphate Pump Y solvent Methanol Combination of UHPLC / HPLC Switching system and solvent blending The solvent blending function can be added to a Nexera UHPLC/HPLC switching system by upgrading the configuration. The system supports all processes from method development to method transfer from HPLC to UHPLC. Nexera UHPLC/HPLC system 1

Enhanced UHPLC Reliability Ultrafast 7-second injection and 14-second cycle time Nexera X2 autosamplers support ultrafast injections to increase analytical throughput. In particular, the SIL-3ACMP achieves a 7-second injection time and a 14-second cycle time, making it ideally suited for ultrafast analysis. 125 1:235.4>86.1(+) 2:256.1>167.1(+) 3:281.1>86.1(+) 14 sec Column Shim-pack XR-ODS II (3 mml. 1.5 mmi.d., 2.2 μm) 1.2 ml/min 1 75 Event # Compound Q1 m/z Q3 m/z 1 Lidocaine 235.4 86.1 5 2 Diphenhydramine 256.1 167.1 25 3 Imipramine 281.1 86.1..25.5.75 1. min Minimizing carryover with multiple rinse solvents The Nexera X2 autosamplers, SIL-3AC and SIL-3ACMP, provide near-zero carryover. The improved design maintains a low carryover level, even during long-term usage, to ensure reliable analysis. AU 2 175 15 125 1 75 5 25 uv 75 5 25.18% 2.25 2.5 2.75 min Column Shim-pack XR-ODS III (15 mml. 2. mmi.d., 2.2 μm) Mobile phase Water / Methanol = 7 / 3.4 ml/min Sample Caffeine 4 mg/l The carryover level was extremely low even after 3, injections. -25..5 1. 1.5 2. 2.5 min Both the SIL-3AC and SIL-3ACMP support the use of multiple rinse solvents for rinsing the needle s outer surface and inner surface to thoroughly minimize carryover. Needle Sample loop Rinse ports Contact surfaces of needle and needle port where carryover is likely to occur Drain Needle port (schematic diagram) R R1 R2 R3 For rinsing needle surface and inner surface (3 types) For rinsing needle surface (1 type) Multi-rinse mechanism can accommodate up to 4 solutions Port section is rinsed by any of the rinse solutions (1 to 3 solutions) Discharge to drain port Ultra High Performance Liquid Chromatograph 11

Nexera X2 Company names, product/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation or its affiliates, whether or not they are used with trademark symbol TM or. Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own. www.shimadzu.com/an/ For Research Use Only. Not for use in diagnostic procedures. The contents of this publication are provided to you as is without warranty of any kind, and are subject to change without notice. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. Shimadzu Corporation, 212 Printed in Japan 3655-822-3ANS