CW Laser Probes For every need. Operating Instructions

Similar documents
Pulsed Laser Probes For every need. Operating Instructions

LightNeedle Bringing light into focus. Operating Instructions

ER75 Electro-Acoustic Ear Simulator. Operating Manual

User Guide and Operating Manual

Convex Array Transducer

MA 25 Operating Manual

Convex Array Transducer

Convex Array Transducer User Guide. Types 8567-S and 8667

For more information visit or contact hearx:

High Frequency Linear Array Transducer

Table of Contents. Introduction Indications For Use Contraindications Warnings Precautions...5

PilotOne II. User Guide

Pain Relief Patch. Operation Manual Read Before Using MODEL # ET

Compatible with the following products TENS. Replacement Pads. User Manual. Last revised: V Last revised: V

Operating Instructions SaHoMa -II mobile ultrasonic nebulizer

Flex-Point HEATED MUSCLE MASSAGER

Joint Relaxation Heated Vibration Massager. Knee and Joint Physiotherapy Unit

Linear Array Transducer

HCS70004P, HCS70004G HCS70004C, HCS70004BL HCS70004DP, HCS70004 AEROMIST COLORS NEBULIZER COMPRESSOR KIT. Instruction Manual

Wireless accessories. Remote Control 3.0. Instructions for use

EVER Pharma D-mine Pen Pen injector for Apomorphine 10 mg/ml

Charging base guide. A Sonova brand

Operating Instructions MA 25

RC-S. Remote Control INSTRUCTIONS FOR USE

Low Row. User manual E S S E N T I A L S T R E N G T H

Allergy Reliever. User Manual. AR 1 Series

Phonak PilotOne II. User Guide

BRS GM100 Glucose Monitoring System. User Instruction Manual Ver. 3.5

User Manual Table of Contents. Instructions for Using the LaserTouchOne Charging the Unit... 5 Holding the Device... 5 Treatment Steps...

Dear HighQ Check System Owner :

User Manual.

Getting started with Wireless Fitting

Transcutaneous Electrical Nerve Stimulation Device GF-3 / GF-3T

Instructions for Use REMOTE CONTROL RC-N

TIP CARD. Model Temporary External Pacemaker

2. Before Testing Monitor Checker Test...10 Inserting Lancets into Lancing Device...11 Quality Control Testing...13

Custom instruments. Insio primax User Guide. Hearing Systems

SIX PACK ABS Item No INSTRUCTION MANUAL. Read entire manual before operating this product. Use only as directed.

INSTALLATION MANUAL. VIDEO Camera, Probe and Lightsource OTOSCOPES.

ENGLISH. USER MANUAL Register your product at: multi-action toothbrush

PLEASE READ THIS USER GUIDE BEFORE OPERATING THE SYSTEM

Application manual for the Trabeculas-Laser 532 nm wavelength

Ear Canal Phones CX 980. Instruction manual

GlucCell TM SYSTEM USER S GUIDE ver 2.3 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System

Laerdal-SonoSim Procedure Trainer

Compressor Nebulizer Instruction Manual Part No.: 5055

SPORTSART C521M BI-DIRECTIONAL BIKE

COMPRESSOR NEBULIZER MODEL: JB USER S MANUAL

Contents Safety Instructions... 4 Package Contents... 6 Notes on Measurements... 7

TRANSCUTANEOUS MECHANICAL NERVE STIMULATOR (TMNS) User s Guide

Compressor Nebulizer. Model UN-014

LeadCare BLOOD LEAD ANALYZER. Quick Reference Guide

Prostate Biplane Transducer

TABLE OF CONTENTS. 2.0 USING MANAGER PREFERENCE 2.1 Using manager preference mode 2.2 Selecting US or metric 2.3 Using CSafe

original consumer purchaser for a period of ninety (90) days from the original

Midwest E Motor. Directions For Use. Doc. No

Oral-B. Oral-B. powered by

Compact Massager Instructions

Compressor Nebulizer System

RaySafe i3 INSTALLATION & SERVICE MANUAL

Epilepsy Sensor Transmitter

Device Preparation (all steps to be performed per standard interventional technique)

Induction loop EZT Instruction manual

FERTI CARE personal. User's Guide. Multicept A/S Frederiksberg Alle 32, 2.th DK-1820 Frederiksberg Denmark

InsuPad User Manual. Charger Base The charger base can be connected by the attached USB cable to the power adapter supplied for charging.

English. Fealite Nasal Pillows System. User Manual

Dr FuelCell Load Measurement Box

User Manual RECHARGEABLE KIT. Includes: 1 PLUS+ rechargeable pack 2 PLUS+ batteries 1 wall charger 1 USB cable 3 Classic Tobacco flavor tanks

CIRCULATORY MASSAGER OPERA TING INSTRUCTION HM01-08QI

Compressor Nebulizer. Guidebook

GlucCell TM SYSTEM USER S GUIDE Ver 2.1 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System

Deep Kneading Shiatsu Massager EXTRA-POWERFUL SHIATSU RELIEF

AWAY Model # RTLAGF-900 REV

Glucose Meter. User Guide. Veterinary Monitoring System. For dog and cat use only

WEIGHT BENCH EXERCISER User s Manual

Implant Locator. User Manual

BODY ANALYZER SCALE PS 8710

Weight And Body Fat! Why do I lose weight but my body fat doesn t change much? Scales by How does it work? Is it accurate?

ESSENTIAL GUIDE. Companion Microphone. How-to videos on hihealthinnovations.com

The Biomet EBI Bone Healing System. Patient Manual

Phone: (866) Website: greatergoods.com

Connect with EatSmart

SelectTech 3.1 Bench Assembly / Owner s Manual

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION

D15525 D15513 D15513T D15511

InWave. User s Manual

Off-line filter system

Compressor Nebulizer. Guidebook

Gronk Massager STRONG, DEEP-KNEADING RELIEF FOR HARD-TO-REACH MUSCLES

PORTABLE COMPRESSOR NEBULIZER Guidebook & Manual Reorder No. 5606

Blood Glucose Monitoring System. User Guide

BeneCheck BK6-12M. Plus Multi-Monitoring Meter and Strips

Cordless 7-in-1 Super Massager WITH INTERCHANGEABLE NODES FOR 7 MAGNIFICENT MASSAGE TECHNIQUES

Multipower. User Guide E S S E N T I A L S T R E N G T H

Introduction. tissue recovery, generates cells renewal and improves micro-circulation.

the range USER MANUAL

Portable Equine Nebuliser System. User Manual

E L E C T R O N I C VA P O R I Z E R S. User Manual

PEMF MAT USER MANUAL. Pulsed Electromagnetic Field Therapy

IMPORTANT SAFETY INSTRUCTIONS

Transcription:

CW Laser Probes For every need Operating Instructions

Contents 1 Introduction... 4 2 Safety information... 5 General information Liability disclaimer Safety standards 3 Safety precautions... 6 Emergency shutdown Treatment area Personnel Radiation injuries Risk of infection Risk of burns Prevent unauthorized use Registration Decommissioning 4 Delivery contents and accessories... 8 5 Applications... 9 Intended use / Indications for use Contraindications / Limitations 6 Startup...11 Checking for transport damage Self-test Automatic probe detection Probe symbols 2

7 Working with probes...13 Remote functions Probe display Changing the contrast Button functions Changing the therapy set Selecting the therapy program Therapy mode 8 Mobile use...18 9 Error messages...19 10 Care and maintenance...20 11 Technical description...21 Technical data Operating conditions Transport and storage Guidelines and manufacturer's declarations Explanation of symbols 12 Warranty and disposal...26 13 Manufacturer/Distributor...27 3

Introduction 1 Your RJ laser probe Thank you for choosing a Reimers & Janssen laser probe. Our extensive probe product line provides the optimum laser probe for every therapy. Whether you're using a surface probe, single probe, or laser needles, all of our highly specialized laser probes are operated by the same control unit, the Physiolaser olympic. With this modular design, we can combine technological innovations with a sophisticated control concept. This brings several advantages for you as a therapist. Once you have familiarized yourself with the intuitive operation of your control unit, you can use another probe in essentially the same way. This means that there is little change in your work routine if you purchase a new probe for additional applications. Your Physiolaser automatically detects which probe is attached and remembers your preferred settings. The Physiolaser even let you use two therapy probes at the same time. Thanks to the modular design, you can always benefit from the latest research innovations because your control unit can be easily updated with the latest therapy programs. With laser probes from Reimers & Janssen, you can utilize the versatile capabilities of gentle laser therapy to achieve the best possible results for your patients. RJ laser probes For every need 4

Safety information 2 General information This device is a laser probe that can only be operated in combination with a control unit, your Physiolaser. Read the operating instructions for your control unit thoroughly before using the probe. These instructions complement the operating instructions for your Physiolaser and cover special functions of the probe. They also describe the commissioning of the device and indicate hazards associated with its use. All individuals who use, care for, service, or supervise this device must read and follow the instructions. These operating instructions must always be kept with the device and must be included with the laser probe if given to others. Liability disclaimer You may use the laser probe only for the purposes described in these operating instructions and only under supervision! The laser probe may only be operated with accessories approved by Reimers & Janssen GmbH and only with a control unit manufactured by Reimers & Janssen GmbH. Currently, this is the Physiolaser olympic (model 172). Never open the device. Any Repair and maintenance work may only be performed by Reimers & Janssen GmbH or a company authorized by Reimers & Janssen GmbH. The manufacturer is not liable for the device and the consequences resulting from operation or applications that are not described within these operating instructions. The manufacturer reserves the right to make changes based on technological improvements. Functions and safety standards The probes conform to the following international safety standards: IEC 60601-1 - Safety of medical electrical devices IEC 60601-1-2 - Electromagnetic compatibility IEC 60601-1-6 - Usability IEC 60601-2-22 - Safety of diagnostic and therapeutic laser devices IEC 60825-1 - Safety of laser products 5

Safety precautions 3 Emergency shutdown Firmly press in the red "Emergency Stop" button on the control unit, turn the safety key to "off", and disconnect the plug for the safety lock "Remote control plug". Treatment area Operate the laser only indoors. The room in which laser therapy is performed must meet the requirements of national accident prevention regulations. All entrances must display a laser warning sign in compliance with IEC 60825-1. Reflective objects, mirrors, and chrome surfaces must be removed. Children may enter the room only as patients and must be under constant supervision. Personnel The laser may be operated only by a trained physician or under the supervision of a trained physician. Any person who uses the device must be instructed in the handling of the device and in the dangers associated with laser radiation. The operator of a Class 3B laser device must have access to a laser safety officer who has professional experience assessing and controlling the hazards associated with lasers, and who will be responsible for the supervision of the protective measures against laser hazards. Radiation injuries Avoid direct or scattered radiation to the eyes. Do not look directly into the laser radiation output area, since visible and invisible laser radiation can cause injury to the eye. SPERIAN 3199-21160RJ laser protective eyewear conforming to the European standard EN 207 must always be worn within the treatment room during treatment. Exercise caution when performing therapy on the head region! When treating patients with darkly pigmented skin, birthmarks, tattoos, etc. be aware of the risk of burning because melanin or color in the skin tissue absorbs the light. Reduce the energy output if the patient has darkly pigmented skin. 6

Risk of infection While performing therapy on damaged skin, keep the probe approx. 1 cm from the skin to avoid direct contact and prevent bacterial contamination. After each treatment, disinfect your probe as described in the chapter Care and maintenance on page 20. If you use an applicator, also disinfect the applicator after each treatment in order to minimize the risk of patient infection. Risk of burns The probe tip may become very hot at high power output and an extended treatment time. In this case, avoid direct skin contact by using a cap or applicator. Otherwise, burns may occur. Alternately, reduce the treatment time. Prevent unauthorized use Your Physiolaser is equipped with a safety key to prevent unauthorized use. The laser can be operated only with the key inserted. When the laser is not in use, the key should always be removed and stored separate from the unit in order to prevent unauthorized use. Registration Operators of the Physiolaser must be registered as an operator of a Class 3B laser device prior to the first commissioning of the device. Observe the applicable national regulations and rules. Decommissioning in the event of a hazard If you believe that the device can no longer be operated safely, it should be decommissioned to prevent against further use and to send it to the distributor for repair. Such cases include: housing components or the probe cable have visible damage the device no longer functions properly the device has been stored or transported for a long period under adverse conditions the display fails or is illegible. 7

Delivery contents and accessories 4 Delivery contents Laser probe Carry bag (soft case) Tip attachment No. 5251 (single probes only) Accessories In addition to manufacturing laser probes in various power output classes and wavelengths, Reimers & Janssen also offers various accessories for our single probes. These applications can be easily screwed onto the product in place of the standard attachment, allowing for even more applications. Available applicators suitable for all CW single probes Item Length Diameter* Item No. Illustration Convex lens 10 mm 523 Quartz tip attachment 2 cm 2 mm 5241 Quartz tip attachment 2 cm 4 mm 5251 *Diameter of the light output area 8

Applications 5 Intended use / Indications for use The laser probe is an electrical device that is intended exclusively for use in medical practices and clinics and may only be operated under constant supervision. Federal law restricts this device to sale by or on the order of a physician. The laser may be operated only by a trained physician or under the supervision of a trained physician. Any person who uses the device must be instructed in the handling of the device, the dangers associated with laser radiation, and compliance with applicable national accident prevention regulations and IEC 60825-1, IEC 60601-22 and CAN/CSA Z386-08. Indications These laser probes are intended to emit energy in the infrared spectrum to provide topical heating for the purposes of elevating tissue temperature when heat is indicated for the temporary relief of minor muscle and joint pain and stiffness, for the temporary relief of minor joint pain associated with arthritis, to temporarily increase local blood circulation where applied and the relaxation of muscles: Model Wavelength Power output CW single probe 50 mw Model 510 A 785 nm max. 50 mw CW single probe 500 mw Model 511 A 810 nm max. 500 mw CW single probe 200 mw Model 512 A 670 nm max. 200 mw CW single probe 150 mw Model 514 A 638 nm max. 150 mw CW multi-cluster probe Model 517 B 785 nm 655 nm 8 x max. 55 mw 4 x max. 40 mw CW multi-cluster probe cuff Model 518 A 785 nm 655 nm 8 x max. 55 mw 4 x max. 40 mw 9

Contraindications / Limitations We advise against the irradiation of the following organs and areas: Eyes Areas near the thyroid gland and other endocrine glands Testicular region Epiphyseal region in children Open fontanel Fetuses or in the area above the uterus of pregnant women Dark, pigmented or colored skin, regions with dark hair No irradiation of the head area in patients with (a tendency to) epilepsy In addition, we advise against treatment of patients with the following indications: Cytostatic immunosuppression Tumor/cancer patients Recommended treatment time Model Treatment time to achieve a skin temperature of 40 45 C Recommended treatment time CW single probe 50 mw Model 510 A 12 min 22 min CW single probe 500 mw Model 511 A 3 min 13 min CW single probe 200 mw Model 512 A 5 min 15 min CW single probe 150 mw Model 514 A 9 min 19 min CW multi-cluster probe Model 517 B 9 min 19 min CW multi-cluster probe cuff Model 518 A 9 min 19 min 10

Startup 6 Checking for transport damage Inspect your probe for damage that may have occurred during transport, i.e., whether the housing components or the probe cable have visible damage. If your probe has a display, remove the protective film and test the display. If you discover any damage, do not operate your probe. Instead, contact your distributor. Self-test Your probe does not require a particular start-up procedure. You can connect the probe to the control unit using the probe cable at any time. However, if you are operating your Physiolaser for the first time, read the operating instructions for your control unit prior to connecting the probe. Your probe will performed a self-test when you turn on the control unit with the probe connected or if you connect the probe to a control unit that is already on. The status indicator flashes briefly during this test. The status indicator flashes during the self-test. Automatic probe detection The Physiolaser will detect a connected probe automatically and the corresponding symbol will be displayed on the therapy selection screen. The software for your control unit may need to be updated if a corresponding symbol does not appear. This may occur if you purchased the new probe for a pre-existing control unit. If this is the case, an SD card is provided with the probe to help you perform the update yourself. Instructions are supplied with the probe. Please contact your distributor. 11

The two laser sockets on the Physiolaser let you use two probes at the same time. Both laser sockets are shown on the therapy selection screen. "Laser 1" corresponds to the left socket and "Laser 2" corresponds to the socket on the right. Probe symbols In addition to single probes and multi-cluster probes, your control unit can also control the LightNeedle probe and the Photonic satellite laser scanner. The different probe types can be easily distinguished by different symbols. These instructions do not describe the special functions of the LightNeedle probe or the Photonic satellite laser scanner. There are separate operating instructions each for the LightNeedle and the Photonic satellite. CW multi-cluster probe CW single probe LightNeedle Photonic satellite 12

Working with probes 7 Remote functions Your probe is operated primarily via the touchscreen on your Physiolaser. Read the instructions for your control unit. These instructions only describe the functions specific to the probes. For ease of use, all probes are equipped with buttons for selecting essential program functions directly from the probe. All probes come with remote functions. Probe display A two-line status display provides information on the set parameters and program sequences. If your Physiolaser is currently in "Stand by" mode, this will also be indicated on the probe display. The buttons on the probe are inactive in this state. RJ Laser Stand by The remote functions can be used once you switch to the therapy selection screen on your control unit by pressing "Ready". "Stand by" indication on the probe display Changing the contrast If the probe display is difficult to read (e.g., in bright sunlight), you can change the contrast in the "Setup Laser" menu on your control unit. "+" and "-" change the contrast on the probe display. 13

Button functions on single probes Start/Stop Start therapy; stop therapy Right arrow Change to next program group, program series, or next therapy program Left arrow Change to previous program group, program series, or previous therapy program Group Change from program groups to program series and therapy programs Buttons on CW multi-cluster probes LASER ON GROUP Left arrow Change to previous program group, program series, or previous therapy program Right arrow Change to next program group, program series, or next therapy program Group Change from program groups to program series and therapy programs Start/Stop Start therapy; stop therapy 14

Selecting therapy programs You can select the desired therapy program on your probe without touching the screen of your control unit. You can scroll through the program groups and series as well as change between the individual programs. A red frame on the therapy selection screen provides orientation when navigating using the buttons. Basis Cont. beam The program series and the therapy program are shown on the probe display. Navigating using buttons Use the Group button to switch between the levels program group, program series, and therapy programs. The display on your control unit indicates that the "Continuous Beam" therapy program in the "Basis" programs series has been selected for the attached probe. Use the arrow buttons to navigate within a level. PROT.2 P2 The red frame provides orientation with navigating with the buttons. 15

Therapy mode You can start therapy at any time from the therapy selection mode by briefly pressing the "Start/Stop" button. This is also possible if another probe has been selected or if another probe is already in therapy mode. In both cases, the most recently selected therapy program is started. During treatment, the patient and personnel must wear SPERIAN 3199-21160RJ laser protective eyewear conforming to European standard EN 207. If the user can not find this model of eyewear he must use an eyewear with following specifications: 405nm D LB4, 650nm D LB2, 655nm D LB3, 670nm D LB4, 785nm D LB2, 810 nm D LB5, 905nm DIR LB6. P2 1.1 :150mW 04:45 Therapy program Energy output Power output Remaining therapy time Once you press the Start button, a twosecond signal tone will sound and the status LED will flash until the onset of the therapy mode. During this time, you can still press the "Start/Stop" button to end the program, for example if you have forgotten to put on protective eyewear. When you press the "Start/Stop" button, the status LED flashes until the onset of the therapy mode. The status indicator remains on during therapy. During the two-second period, the 50 mw single probe emit a visible but harmless pilot beam that helps you find the exact therapy location. The status indicator remains on during therapy. The end of therapy is indicated by a long signal tone. The current therapy program can be stopped at any time by pressing the "Start/Stop" button. All buttons are active in therapy mode so you can also change the program during a treatment. Stop the current therapy program using the Start/Stop button. 16

Caution when using the 500 mw CW single probe The tip of the 500 mw CW single probe may overheat if operated at full power for an extended treatment time. As a result, this probe must never be used without an attachment or applicator. Otherwise, the probe tip may become too hot and cause burns on skin contact. The 500 mw CW single probe should not be operated at full power for more than five minutes. For longer treatments at full power, pause treatment for at least one minute after every five minutes of treatment. 17

Mobile use 8 Battery life With the compact Physiolaser olympic you can also use your probe in battery mode. Many different factors determine how long you can actually perform treatment in practice with a full battery. The ambient temperature as well as the selected program and the power output all play a role. CW multi-cluster probe in CW mode We have conducted a test run for both probe types and documented the results below. The testing conditions were: battery fully charged at the start, with treatments of 10 minutes each at room temperature. 500 mw CW single probe at 10 khz 1.3 hours 8 treatments can be performed Therapy time: 10 minutes Power output: 600 mw Therapy program: CW 1.5 hours 9 treatments can be performed Therapy time: 10 minutes Power output: 500 mw Therapy program: CW 18

Error messages 9 Defective laser diodes Please also read the chapter "Error messages" in the operating instructions for your Physiolaser. Error messages only appear on the probe itself in case of defective laser diodes. The therapy program can no longer be started or it is automatically stopped (in an error occurs during ongoing therapy). Please contact your distributor for repair. Error messages on single probes Laser 1 defect Error message on single probe displays Error messages on multi-cluster probes Laser x defect The "X" stands for the number of the defective diode. 19

Care and maintenance 10 Cleaning and disinfection Unplug the power cord of your control unit before beginning any cleaning or maintenance. Note that harsh or caustic agents (e.g., acetone) must not be used for regular cleaning of the plastic components. Prevent moisture from entering the housing. It is best to use a damp cloth for cleaning. To disinfect the device, use a soft cloth that has been dampened with a mild disinfectant. Always use a damp cloth for cleaning and disinfection. Never flush water over the device. Do not use solvents! If you use an applicator, disinfect the applicator after each treatment in order to minimize the risk of patient infection. Calibration and safety check Your laser probe does not contain any user-serviceable internal parts or components. There is thus no reason to open the device's housing. To comply with IEC 60825-1 (Safety of laser products), your Physiolaser olympic, along with all probes and accessories, must be inspected and recalibrated by the manufacturer at least once annually. Please contact your distributor. 20

Technical description 11 Technical data Class 3B laser therapy device Absolute uncertainty of laser power measurement 20% Modulation frequency 1 Hz to 99999 Hz Accuracy of the electric conductance measurement +/- 10 % Operating conditions Ambient temperature + 10 C to +30 C Relative humidity 30% to 75% Air pressure 700 hpa to 1060 hpa Transport and storage Ambient temperature -20 C to +40C 21

Single probes Wavelength Power output Laser type NOHD* Beam divergence CW single probe 50 mw Model 510 A CW single probe 150 mw Model 514 A CW single probe 200 mw Model 512 A CW single probe 500 mw Model 511 A 785 nm Max. 50 mw Continuous wave (CW) 638 nm Max. 150 mw Continuous wave (CW) 670 nm Max. 200 mw Continuous wave (CW) 810 nm Max. 500 mw Continuous wave (CW) 0.10 m 0.140 rad 0.08 m 0.410 rad 0.14 m 0.209 rad 0.29 m 0.157 rad * Safety margin (NOHD): The distance at which the radiation intensity or radiation is equal to the corresponding limit for the maximum permissible radiation of the cornea (MPE = maximum permissible exposure). Multi-cluster probes Wavelength Power output Laser type NOHD* Beam divergence CW multicluster probe Model 517 B CW multicluster probe cuff Model 518 A CW multicluster probe Model 508 785 nm 655 nm 785 nm 655 nm 8 x max. 55 mw 4 x max. 40 mw 8 x max. 55 mw 4 x max. 40 mw Continuous wave (CW) Continuous wave (CW) 655 nm 12 x max. 50 mw Continuous wave (CW) 0.10 m 0.09 m 0.10 m 0.09 m 0.140 rad 0.157 rad 0.140 rad 0.157 rad 0.09 m 0.157 rad 22

Wavelength Power output Laser type NOHD* Beam divergence CW multicluster probe Model 509 810 nm 638 nm 1 x max. 500 mw 1 x max. 150 mw Continuous wave (CW) > 10 m > 10 m 0.003 rad 0.003 rad * Safety margin (NOHD): The distance at which the radiation intensity or radiation is equal to the corresponding limit for the maximum permissible radiation of the cornea (MPE = maximum permissible exposure). All probes are equipped with a red LED that functions as the status indicator. 23

LASER FREQUENCY LASER ON CW multi-cluster probe: Position of labels on the device 1 2 3 4 3 1. Laser warning label 2. Type label 3. Laser warning labels 4. Rating label CW multi-cluster probe: Explanation of symbols and labels on the device Signs on the type label Type label Probe type 517B Pmax: 8 x 55 mw / 785 nm + 4 x 40 mw / 655 nm SN:11517B-18 Probe type 517B Pmax: 8 x 55 mw / 785 nm + 4 x 40 mw / 655 nm SN:11517B-18 10-2011 Probe type 517B Reimers & Janssen GmbH Fabrikstraße 22 D-79183 Waldkirch Pmax: 8 x 55 mw / 785 nm + 4 x 40 mw / 655 nm 10-2011 8 x 55 mw / 785 cw 10-2011 SN:11517B-18 10-2011 Rating and warning labels Probe type 517B Reimers & Janssen GmbH Fabrikstraße 22 D-79183 Waldkirch Reimers Janssen GmbH Fabrikstraße 22 D-79183 Waldkirch EN &60825-1:2007 4 x 40 mw / 655 nm cw 8 x 55 mw / 785 cw EN 60825-1:2007 Austrittsöffnung für sichtbare und unsichtbare Laserstrahlung Nicht dem Strahl aussetzen Pmax: 8 x 55 mw / 785 nm + 4 x 40 mw / 655 nm 4 x 40 mw / 655 nm cw Reimers Janssen GmbH Fabrikstraße 22 D-79183 Waldkirch EN &60825-1:2007 Nicht dem Strahl aussetzen 10-2011 Laser warning labels 8 x Austrittsöffnung 55 mw / 785für cwsichtbare und unsichtbare Laserstrahlung ENNicht 60825-1:2007 dem Strahl aussetzen Laser beam exit aperture Avoid direct exposure to beam No rating against harmful ingress of water 10-2011 Rating label Austrittsöffnung für sichtbare 8 xund 55unsichtbare mw / 785Laserstrahlung cw 10-2011 SN:11517B-18 4 x 40 mw / 655 nm cw 10-2011 4 x 40 mw / 655 nm cw The device complies with European directives applicable to the product. 04-2011 Observe the accompanying documentation. Type B applied part Date of production Month - Year 24

Single probes: Position of labels on the device 1 2 3 4 1. Laser warning label on top 2. Laser warning label on bottom 3. Rating label 4. Type label Single probes: Explanation of symbols and labels on the device Type label Signs on the type label Probe type 511A Pmax: 500 mw / 810 nm SN:10511A-72 Probe type 517B Pmax: 8 x 55 mw / 785 nm + 4 x 40 mw / 655 nm SN:11517B-18 12-2010 Probe type 511A Reimers & Janssen GmbH Fabrikstraße 22 D-79183 Waldkirch Pmax: 500 mw / 810 nm 10-2011 Pmax 500 mw λ = 810 nm cw SN:10511A-72 10-2011 12-2010 Probe type 511A Reimers & Janssen GmbH Fabrikstraße 22 D-79183 Waldkirch Reimers Janssen GmbH Fabrikstraße 22 D-79183 Waldkirch EN &60825-1:2007 4 x 40 mw / 655 nm cw 8 x 55 mw / 785 cw EN 60825-1:2007 Austrittsöffnung für sichtbare und unsichtbare Laserstrahlung Nicht dem Strahl aussetzen Rating warning labels Pmax: 500and mw / 810 nm Pmax 500 mw und unsichtbare Austrittsöffnung für sichtbare 12-2010 λ = Laserstrahlung 810 nm cwklasse12-2010 3BRating label SN:10511A-72 Reimers &Nicht Janssen Fabrikstraße 22 D-79183 Waldkirch dem GmbH Strahl aussetzen EN 60825-1:2007 Pmax 500 mw 12-2010 12-2010 Laser warning labels Austrittsöffnung für sichtbare und unsichtbare λ = Laserstrahlung 810 nm cwklasse 3B Nicht dem Strahl aussetzen EN 60825-1:2007 Laser beam exit aperture 04-2011 The device complies with European directives applicable to the product. No rating against harmful ingress of water Observe the accompanying documentation. Type B applied part Date of production Month - Year Laser category 3B Avoid direct exposure to beam 25

Warranty and disposal 12 Warranty The manufacturer s warranty is valid for 24 months. The manufacturer is only responsible for the features as warranted by the operating instructions if the device has been operated carefully and in accordance with the operating instructions. Readjustment, calibration, and maintenance or repairs may only be performed by the distributor, otherwise the warranty is void. Any alterations to the device by unauthorized third parties void the warranty. The manufacturer guarantees spare parts availability for a period of ten years after the date of purchase. Disposal Due to the hazards of laser radiation, probes and control units may not be disposed of as normal electronic waste. The devices must be sent to the manufacturer for decommissioning and disposal. 26

Manufacturer/Distributor 13 REIMERS & JANSSEN GmbH Medical Laser Technology Fabrikstraße 22 79183 Waldkirch, Germany Tel. +49 (0) 7681-493 4149 Fax +49 (0) 7681-493 4150 service@rj-laser.com www.rj-laser-usa.com Quality management EN ISO 13485: 2003 + AC: 2009 Publisher Reimers & Janssen GmbH Medical Laser Technology Editor Ulrich Sackenreuter Design & Illustrations Eike Otto Photographs Volker Weinhold Version US 1.2 18-July-2014 Distributor 27