journal ORIGINAL RESEARCH

Similar documents
)451( COPYRIGHT 2017 BY THE ARCHIVES OF BONE AND JOINT SURGERY. Evaluation of Normal Ranges of Wrist Radiologic Indexes in Mashhad Population

Radiographic Evaluation and Classification of Distal Radius Fractures

Essential Radiographic Evaluation for Distal Radius Fractures

Effects of Malunited Fractured Distal End of Radius on the Morphometric Parameters of Distal Radioulnar Joint in Old Age Group

University of Groningen. Fracture of the distal radius Oskam, Jacob

Hand and wrist emergencies

Radiographic indices in one hundred fifty normal Iranian wrists

SCAHPO-LUNATE DISSOCIATION

Scapholunate Ligament Lesions Imaging Which and when?

Interesting Case Series. Perilunate Dislocation

Index. Note: Page numbers of article titles are in boldface type. Hand Clin 21 (2005)

Introduction. The wrist contains eight small carpal bones, which as a group act as a flexible spacer between the forearm and hand.

RADIOGRAPHIC MORPHOMETRY OF DISTAL END OF RADIUS, A RETROSPECTIVE, OBSERVATIONAL STUDY IN INDIAN POPULATION

Measurement of Ulnar Variance on Uncalibrated Digital Radiographic Images

RADIOGRAPHY OF THE WRIST

A study of the radiographic morphometry of the distal radius in a south Indian population

Factors Predicting Late Collapse of Distal Radius Fractures

Complications of Distal Radius Fractures. How to Treat a Distal Radius Fx 11/13/2017. Michael S. Bednar, M.D. Loyola University Chicago

Degrees Of Volar Angulation In Distal Radius Fracture Effects Distal Radioulnar Joint Stability:a Biomechanical Study

NIH Public Access Author Manuscript J Hand Surg Am. Author manuscript; available in PMC 2014 January 01.

Cover Page. The handle holds various files of this Leiden University dissertation.

Common Limb Fractures. Mr Sheraz Malik MB BS MRCS Instructor Mr Paul Ofori-Atta Mb ChB FRCS President Motc Life UK April 2009

University of Groningen. Fracture of the distal radius Oskam, Jacob

Kousuke Iba 1*, Yasuhiro Ozasa 1, Takuro Wada 1, Tomoaki Kamiya 1, Toshihiko Yamashita 1, Mitsuhiro Aoki 2. Abstract

Acute Wrist Injuries OUCH!

Radiographic observation of the scaphoid shift test

Surgical correction for supination loss following malunited radial fractures

Mark VanDer Kaag 1, Ajmal Ikram 2. Hand Unit, Tygerberg Hospital University of Stellenbosch

3. Ulno lunate, Ulno triquetral ligament. Poirier: Between RSC &LRL. 5. Dorsal intercarpal ligament

ORIGINAL ARTICLE. possible. Accurate assessment of standard radiographs is essential for appropriate 3. management. And includes true posterior- 4

Scaphoid Fractures. Mohammed Alasmari. Orthopaedic Surgery Demonstrator Majmaah University

Hands PA; Obl. Lat.; Norgaard s Thumb AP; Lat. PA. PA; Lat.: Obls.; Elongated PA with ulnar deviation

Dynamic CT Assessment of Distal Radioulnar Instability

EXAMINATION OF THE WRIST BEYOND THE BASICS OMA SPORT MED Janice Harvey MD CCFP CFFP Dip. Sp Med.

Ultrasound-guided reduction of distal radius fractures

ORIGINAL PAPER. Department of Hand Surgery, Nagoya University School of Medicine ABSTRACT

The Role of Lunate Morphology on Scapholunate Instability and Fracture Location in Patients Treated for Scaphoid Nonunion

Interesting Case Series. Ulnolunate Impaction Syndrome

Long-term Outcomes of Ulnar Shortening Osteotomy for Idiopathic Ulnar Impaction Syndrome: At Least 5-Years Follow-up

Standardised post-operative radiographs for volar radial plate fixation: the 22/11 X-ray

UvA-DARE (Digital Academic Repository) 3D imaging in corrective osteotomy of the distal radius Vroemen, Joy. Link to publication

CASE REPORT. Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report

IS CASTING AN ACCEPTABLE TREATMENT APPROACH FOR A DISTAL RADIUS FRACTURE THAT HAS UNDERGONE A SATISFACTORY CLOSED REDUCTION?

Wrist movements, apart from the distal radioulnar joint, take place in two planes:

FOOSH It sounded like a fun thing at the time!

This presentation is the intellectual property of the author. Contact them for permission to reprint and/or distribute.

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are

Triangular Fibrocartilage Complex Repair. The triangular fibrocartilage complex (TFCC) is one of the main stabilizers of the

Abstract Submission Form

Sean Walsh Orthopaedic Surgeon Dorset County Hospital

Modular Ulnar Head surgical technique. Transforming Extremities

International Journal of Health Sciences and Research ISSN:

University of Groningen. Fracture of the distal radius Oskam, Jacob

ROLE OF LOCKING COMPRESSION PLATES IN THE TREATMENT OF FRACTURES DISTAL END OF RADIUS

Common Forearm Fractures in Adults

Emile N. Brown, MD, and Scott D. Lifchez, MD

Neglected trans-scaphoid trans-styloid volar dislocation of the lunate

Distal radius fractures raises considerable interest and

Reliability of Lichtman s classification for Kienböck s disease in 99 subjects

A Slightly Dorsally Tilted Lunate on MRI can be Considered Normal

Department of Orthopedic Surgery, Konyang University Hospital, Daejeon, Korea

Conservative management of palmer mid-carpal instability

Complications and functional outcome following fixation of complex, intra-articular fractures of the distal radius with the AO Pi-Plate

Cover Page. The handle holds various files of this Leiden University dissertation.

The Utility of the Fluoroscopic Skyline View During Volar Locking Plate Fixation of Distal Radius Fractures

Fracture of the Distal Radius: Epidemiology and Premanagement Radiographic Characterization

PREVIEW ONLY 27/10/2014. Instabilities in the Wrist

Intra articular distal radius fractures and volar plate fixation: a prospective study

Redisplacement of Distal Radius Fracture after Initial Closed Reduction: Analysis of Prognostic Factors

Malunited extra-articular distal radius fractures: corrective osteotomies using volar locking plate

A Patient s Guide to Adult Distal Radius (Wrist) Fractures

University of Groningen. Fracture of the distal radius Oskam, Jacob

The role of the transverse carpal ligament in carpal stability : An in vitro study

Comparison between Distractor Application on Both Radial & Ulnar Side and Radial Side Only for Fracture Distal Radius with Ulnar Styloid Fracture

Acomparison of percutaneous and pin-and-plaster techniques in distal radius fracture

Conservative treatment of the distal radius fracture using thermoplastic splint: pilot study results

FOOSH It sounded like a fun thing at the time!

A prospective study of surgical management of distal radius fracture in adult with plate fixation

Functional Outcome in Distal Radius Fractures Treated with Locking Compression Plate

Operative Indications

A STUDY OF THE FUNCTIONAL OUTCOME OF LOW PROFILE DORSAL PLATING IN DISTAL END RADIUS FRACTURES

Distal radius fractures are

Clinical Study Dorsally Comminuted Fractures of the Distal End of the Radius: Osteosynthesis with Volar Fixed Angle Locking Plates

Disclosure. 85% Dorsal. 15% Volar. Distal Radius Fractures- Volar Plating for All. Skeletal Dynamics- Consultant

ORTHOSCAN MOBILE DI POSITIONING GUIDE

RADIOGRAPHY OF THE HAND, FINGERS & THUMB

Trans-scaphoid Perilunate Fracture-dislocation with Concomitant Lunotriquetral Ligament Disruption: A Case Report

GALEAZZI FRACTURE. Galeazzi fracture-dislocations can be difficult to recognize and are often not initially appreciated.

Acute Rupture of Flexor Tendons as a Complication of Distal Radius Fracture

The Kienböck disease and scaphoid fractures. Mariusz Bonczar

WEEKEND 2 Elbow. Elbow Range of Motion Assessment

The value of manipulation of displaced distal radius fractures in the emergency department

COMPARATIVE STUDY OF FUNCTIONAL OUTCOME OF EXTERNAL AND INTERNAL FIXATION IN TREATMENT OF COMMINUTED DISTAL RADIUS FRACTURES

Fractures of the distal end of the radius should be

Scaphoid Fractures- Anatomy And Diagnosis: A Systemic Review Of Literature

Proximal radioulnar translocation associated with elbow dislocation and radial neck fracture in child: a case report and review of literature

NE Nebraska Trauma Conference Tristan Hartzell, MD November 8, 2017

Do Radiographic parameters predict Functional Outcome in Distal end Radius Fracture?

Link to related CJSM article: ts Frequency_and.5.

Transcription:

texas orthopaedic journal ORIGINAL RESEARCH Assessment of Volar Tilt Measurements with Variations in X-Ray Beam Centralization Along the Longitudinal Axis of the Radius Russell A. Wagner, MD; Will Junius, MD; Wade Krause, MD; Scott Cole, MD; David Lichtman, MD Department of Orthopaedic Surgery University of North Texas Health Science Center, Fort Worth, TX ABSTRACT Introduction: The need for adequate restoration of volar tilt to prevent potentially debilitating sequelae in fractures of the distal radius is well documented. The relationship of this measure to variations in X-ray beam centralization along the longitudinal axis of the radius was investigated. Methods: Twenty-one healthy, skeletally mature male volunteers were selected. Radiographs of the distal radius using both a mini C-arm and a portable X-ray machine were taken at four positions: centered on the radial styloid, 3 cm distal, 3 cm proximal, and 5 cm proximal to the styloid. Two orthopaedic faculty independently measured volar tilt on each of the 16 remaining sets and inter- and intraobserver reliability were measured. Results: On both the mini C-arm and the portable X-ray images, the measured volar tilt increased as the beam moved proximally along the longitudinal axis of the radius. The mini C-arm group averaged a difference of 1.4 deg/cm offset, with an average decrease in volar tilt of 11 deg from the most proximal to the most distal centralization. The standard X-ray group averaged a difference of 0.28 deg/cm of offset, with an average decrease of 2 deg of volar tilt from the most proximal to the most distal centralization. Discussion: This study demonstrates a clear relationship between beam centralization and volar tilt measurement. As the beam is moved proximally, volar tilt increases. Owing to a greater angle of measurement, this variance is much greater when using the mini C-arm than with standard X-ray. Keywords: Volar tilt; Radiography; Inter- and intraobserver reliability. INTRODUCTION Distal radius fractures are among the most common injuries encountered by orthopaedic surgeons. They account for Corresponding Author: Russell A. Wagner, MD Department of Orthopaedic Surgery University of North Texas Health Science Center 1500 S. Main St. Fort Worth, TX 76104, USA e-mail: russell.wagner@unthsc.edu 15-20% of all extremity fractures, and represent one-sixth of all fractures treated in emergency departments (1). Several radiographic parameters have been established to evaluate these fractures on both posteroanterior (PA) and lateral views. Parameters evaluated on the PA view include radial inclination, radial height, ulnar variance, and articular step-off. DOI: 10.18600/toj.0101.02 TOJ 1: 15-21, 2015

Wagner et al. Volar tilt, as determined on the lateral view, is an angle formed by a line drawn perpendicular to the shaft of the radius and one drawn in the dorsal-to-palmar direction along the distal articular surface of the radius (Figure 1). Volar tilt has an accepted normal range of 0-28 degrees (average of 11-12) (1). The importance of re-establishing volar tilt to at least neutral for dynamic wrist function is well documented (1,2). Residual dorsal angulation results in such conditions as dorsal intercalated segment instability, persistent pain (3), dorsal carpal subluxation (4), decreased grip and pinch strength (5), altered pressure distribution at the radiocarpal joint (6), and incongruency of the distal radioulnar joint (7). Previous studies have demonstrated that variations in radiographic techniques alter volar tilt measurements. These alterations can involve positioning of the forearm or X-ray beam. Johnson and Szabo (8) showed that a 5-degree rotational change in the forearm caused a 1.6-degree change in volar tilt. Supination increased and pronation decreased the measure. Friberg and Lundstrom (9) demonstrated that directing the beam 15 degrees cephalad decreased volar tilt. In clinical practice splints or casts often obscure anatomic landmarks, making it easy for the center of the beam to vary between X-rays. In the case of taking a lateral forearm film, it may be difficult to center the beam directly over the radial styloid. Thus, the centralization of the beam may change at follow-up visits. This variability may lead to variability in the measurement of volar tilt, which may erroneously influence treatment decisions. The present study aims to evaluate whether changes in centralization of the X-ray beam along the longitudinal axis of the radius affect measurements of volar tilt. MATERIALS & METHODS Figure 1. Volar tilt is measured on lateral view as an angle between a line perpendicular to the radius shaft and its distal articular surface. After IRB approval was obtained, 21 skeletally mature male volunteers with no prior history of fracture, operative intervention, congenital anomalies, or signs or symptoms of an upper extremity disorder were selected, and informed consent was obtained. A radiolucent jig was constructed. The jig ensured neutral forearm rotation by using a standard aluminum wrist splint, and enabled calibrated movements along the longitudinal axis of the radius. The participants arms were placed in 90 degrees of shoulder abduction, 90 degrees 16 TOJ 1: 15-21, 2015

Volar Tilt Measurements of elbow flexion and neutral forearm rotation (Figure 2), the standard position for a lateral radiograph of the distal forearm and wrist (10). Both the OEC 6600 mini C-arm and the Siemens Sireskop 5 portable X-ray machines were used to obtain radiographic images at four different positions. Position 0: centered on the radial styloid, position +3: centered 3 cm proximal to the radial styloid, position +5: centered 5 cm proximal to the radial styloid, and position -3: centered 3 cm distal to the radial styloid (Figure 3). To ensure that any variations in volar tilt were due solely to changes in beam position, the extent to which the cortices of the distal scaphoid pole and the capitate head were overlain by the palmar cortex of the pisiform was assessed for each set of radiographs. This scaphopisocapitate relationship needed to remain constant among the different films (10). Five sets of radiographs were excluded due to variation in this relationship, leaving 16 sets of X-rays. (-)3 0 (+)3 (+)5 Figure 3. Images were taken at four different positions: position 0 centered on the radial styloid; position +3 centered 3 cm proximal to the radial styloid; position +5 centered 5 cm proximal to the radial styloid; position -3 centered 3 cm distal to the radial styloid. Figure 2. For the standard position for a lateral radiograph of the distal forearm and wrist, the arm was positioned in 90 degrees of shoulder abduction, 90 degrees of elbow flexion, and neutral forearm rotation. After the acceptable sets of radiographs were determined, two orthopaedic faculty observers were chosen to measure volar tilt. The standard method of measurement as described above was used, and each radiograph was measured twice by both observers. The observers were blinded to the position of the beam. As another measure to evaluate the centralization of beam position over the radial TOJ 1: 15-21, 2015 17

Wagner et al. styloid, the distance between the shadow of the proximal articular surface of the scaphoid and that of the proximal articular surface of the lunate were measured. We termed this distance the scapholunate proximal articular surface (SPAS) distance. RESULTS The mean volar tilt values found at the four positions for both the mini C-arm and standard X-ray radiograph sets are listed in Table 1. Both of these data sets yielded linear relationships (Figure 4). The slope of the C-arm group can be described with the equation y=1.3986x + 8.1517 (R 2 =0.993), and the same for the standard X-ray is y=0.2776x + 8.5531 (R 2 =0.9564). Table 1. The mean volar tilt measured at the four positions for both the mini C-arm and standard X-ray. Mini C-arm Mean Palmar Tilt (degrees) Position (degrees) Position (degrees) Standard X-ray Mean Palmar Tilt (degrees) 4.3-3 -3 7.9 7.7 0 0 8.3 12.1 +3 +3 9.3 15.5 +5 +5 10.1 Statistical analysis of the mini C-arm data yielded the following information. Paired-samples t-test showed t-value of 6.89 (p<0.0001). This shows a statistical difference between observers (average measured difference 2.92 degrees). The average change in volar tilt measure for every 1 cm beam offset was 1.4 degrees, and an average increase of 11.2 degrees from -3cm (distal) position to +5cm (proximal) was found. One-way ANOVA showed a composite F value of 37.66 (p<0.0001) showing a significant difference between all data points (beam positions). After applying statistical analysis to the standard X-ray data, the following information was found. No statistical difference between the two separate measurements made by individual observers or between the different observers was found. A statistically significant difference was found between the +5 and 0 position as well as between the +5 and -3 position (p<0.05). The average increase in volar tilt measurement from the -3cm (distal) to +5cm (proximal) position was 2.2 degrees. The scapholunate proximal articular surface (SPAS) distance was also calculated on these films. The SPAS distance was found to increase as the beam moved from distal to proximal (Figure 5). A statistically significant difference was found between all groups (p<0.05) with the exception of +3 to +5 cm (p=0.053). DISCUSSION Distal radius fractures are one of the most common fractures encountered by orthopaedists. They constitute approximately 15-20% of all extremity fractures (1). Failure to adequately reduce these fractures can lead to the development of several debilitating conditions. Volar tilt is one of the primary measures used to establish adequate reduction, and ensuring that it is measured correctly is of vital importance. Prior studies by Johnson and Szabo (8) showed that rotational changes can affect this measure, and Frieberg and Lundström (9) showed that tilting the beam cephalad also affected the measure. The current study clearly demonstrates that changes in 18 TOJ 1: 15-21, 2015

Volar Tilt Measurements Figure 4. The average volar tilt at the four positions for both the mini C-arm and standard X-ray radiograph yielded linear relationships. Figure 5. The scapholunate proximal articular surface (SPAS) distance was found to increase as the beam moved from distal to proximal. TOJ 1: 15-21, 2015 19

Wagner et al. beam centralization along the longitudinal axis of the radius causes variability in volar tilt measurements, with an increase in volar tilt as the beam is moved proximally. The great disparity in volar tilt variance (11.2 degrees vs 2.2 degrees) between the mini C-arm and the standard X-ray can be explained mathematically. The distance from wrist to beam source when using the mini C-arm was 36 cm, and when using standard X-rays was 110 cm. Thus, moving the respective beams along the longitudinal axis of the radius had a much greater effect on the angle between the beam source and wrist when using the mini C-arm vs the standard X-ray. This increased angle variance over the longitudinal excursion of the mini C-arm beam led to an increased variance in volar tilt measurement. The SPAS distance as described above also varies with longitudinal changes in beam position. Thus, this distance can be used to estimate consistency of beam position between images. This measurement could be of particular usefulness in the case of comparing mini C-arm images, which are more prone to variations in volar tilt measures with inconsistent beam positions. Clinically, this implies that standard X-rays should be chosen over the mini C-arm to evaluate palmar tilt because they are less sensitive to changes in beam centralization. For standard X-rays, an 8 cm variance produces only 2.2 degrees of difference in volar tilt, and this difference is less likely to affect a decision about treatment. CONCLUSIONS This study demonstrates a clear relationship between beam centralization and volar tilt value. As the beam is moved proximally, volar tilt increases. Owing to a greater angle of measurement, this variance is much greater when using the mini C-arm than with standard radiography. Thus, it is our recommendation that standard X-rays be preferred over the mini C-arm to evaluate palmar tilt. However, if the mini C-arm is used, the distance between the proximal articular surfaces of the scaphoid and lunate can be used as an approximation of the consistency of beam position. REFERENCES 1. Simic PM, Weiland AJ. Fractures of the distal aspect of the radius: changes in treatment over the past two decades. Instr Course Lect. 2003;52:185-95. 2. Arora R, Gabl M, Gschwentner M, Deml C, Krappinger D, Lutz M. A comparative study of clinical and radiologic outcomes of unstable Colles type distal radius fractures in patients older than 70 years: nonoperative treatment versus volar locking plating. J Orthop Trauma. 2009;23:237-42. 3. Nana AD, Joshi A, Lichtman DM. Plating of the distal radius. J Am Acad Orthop Surg. 2005;13:159-71. 4. Park MJ, Cooney WP, Hahn ME, Looi KP, An KN. The effects of dorsally angulated distal radius fractures on carpal kinematics. J Hand Surg Am. 2002;27:223-32. 5. Rubinovich RM, Rennie WR. Colles fracture: end results in relation to radiologic parameters. Can J Surg. 1983;26:361-3. 6. Short WH, Palmer AK, Werner FW, Murphy DJ. A biomechanical study of distal radius fractures. J Hand Surg Am. 1987;12:529-34. 20 TOJ 1: 15-21, 2015

Volar Tilt Measurements 7. Kihara H, Palmer AK, Werner FW, Short WH, Fortino MD. The effect of dorsally angulated distal radius fractures on distal radioulnar joint congruency and forearm rotation. J Hand Surg Am. 1996;21:40-7. 8. Johnson PG, Szabo RM. Angle measurements of the distal radius: a cadaver study. Skeletal Radiol. 1993;22:243-6. 9. Friberg S, Lundström B. Radiographic measurements on the radio-carpal joint in distal radial fractures. Acta Radiol Diagn (Stockh). 1976;17:869-76. 10. Mann FA, Wilson AJ, Gilula LA. Radiographic evaluation of the wrist: what does the hand surgeon want to know? Radiology. 1992;184:15-24. TOJ 1: 15-21, 2015 21

22