D-DIMER EXERCISE

Similar documents
Fibrinogen, Ddimer and Factor XIII testing Data from UK NEQAS (Blood Coagulation) Disclosure. Factor XIII. UK NEQAS data

ECAT FOUNDATION REPORT

The Role of D-Dimer in the Diagnosis of Venous Thromboembolism

Internal Quality Control in the Haemostasis laboratory. Dr Steve Kitchen Sheffield Haemophilia and Thrombosis centre & UK NEQAS Blood Coagulation

The following shows the question asked, the format for the answer, and the main results of each question.

Insights on the Quality of Coagulation Testing

Bio-Rad Laboratories. Cardiac Assessment Controls. Value Assigned for Clinical Laboratory and Point of Care Test Systems

Quantitative measurement of 6 analytes in parallel

Clinical suspicion for venous thromboembolism (VTE) mandates objective testing to

ECAT FOUNDATION REPORT

Factor VIII Inhibitor Testing: Nijmegen Modifications, Experience and Recommendations

METHOD VALIDATION: WHY, HOW AND WHEN?

Review. Widely Used Types and Clinical Applications of D-Dimer Assay

Review. Widely Used Types and Clinical Applications of D-Dimer Assay

Individual Lab Report Ci-Trol Nov,2016. Abnormal Fibrinogen (mg/dl) Abnormal Fbg Control - Lot# LFC Your Lab

Quantitative Measurement of Emergency Biomarkers in Parallel

How Good is your INR? The Use of Certified Plasmas in PT/INR Testing. INR System. How Good is your INR? Outline

D-Dimer for venous thromboembolism diagnosis: 20 years later

UKNEQAS Toxoplasma Serology. It is the fault of the kits or is it?

Quantitative Measurement of Cardiac Biomarkers

FINAL REPORT HBV Serology External Quality Assessment Scheme

VIDRL & WHO Measles IgM Proficiency Panel Final Report Prepared by Jennie Leydon, Michaela Riddell & Dr Mike Catton Director VIDRL

Cover Page. The handle holds various files of this Leiden University dissertation

Multiple studies are available concerning the use of

Cardiac Assessment Controls

Quantitative measurement of 6 analytes in parallel hs Trop I, NTproBNP, D-Dimer, hscrp, Myoglobin, HCG, CK-MB mass

AccuVert HIV-1 Seroconversion Panel PRB955 ( ) / Batch #

Comparison of Three Methods for Measuring Factor VIII Levels in Plasma

The usefulness of five D-dimer assays in the exclusion of deep venous thrombosis

Point of Care Testing in Coagulation

AFIAS 6 (Automatic Fluorescence Immuno-Assay)

Eenduidige diagnostiek van longembolie: progress after YEARS

Most primary care patients with suspected

Triage D-Dimer Test. Pulmonary embolism? A rapid disposition can be a matter of life or death.

Mouse Cathepsin B ELISA Kit

HIV Viral Load Quality Assessment Program Summary for Panel HIVVL 2018Oct26

Pulmonary embolism? A rapid disposition can be a matter of life or death.

Rat TSH ELISA KIT. Please, read this instruction carefully before use.

Coagulation and Transfusion Medicine

Impact of Delay in Clinical Presentation on the Diagnostic Management and Prognosis of Patients with Suspected Pulmonary Embolism

Missy Wittenzellner Big Brother Big Sister Project

Elevated Urine Zinc Concentration Reduces the Detection of Methamphetamine, Cocaine, THC and Opiates in Urine by EMIT

HIV Viral Load Quality Assessment Program Summary for Panel HIVVL 2017Oct27

High D-dimer levels increase the likelihood of pulmonary embolism

Cardiac Assessment Controls A critical element of reliable cardiac testing

Table. Analytical characteristics of commercial and research cardiac troponin I and T assays declared by the manufacturer.

Using the Patient Reported Outcome Measures Tool (PROMT)

HIV Serology Quality Assessment Program Summary for Panel HIVSER 2017Apr19

HIV-1 AccuVert TM Seroconversion Panel

Smart Diagnostics for Point-of-Care!

Mouse Leptin ELISA Kit Instructions

The PATH to better cardiac care starts here

What can we learn from EQAs and audits for cardiac marker testing?

Christopher M. Lehman, MD, 1,3 Lori W. Wilson, MT(ASCP), MS, 3 and George M. Rodgers, MD, PhD 1-3. Abstract

Mouse C-Peptide ELISA Kit

No influence of heparin plasma and other (pre)analytic variables on D-dimer determination

Eileen Crimmins 1 Jianwei Hu 2 Peifeng Hu 3 Wei Huang 2 Jungki Kim 1 Yuhui Shi 2 John Strauss 1 Lu Zhang 1 Xiaohui Zhao 2 Yaohui Zhao 2

Diagnostic accuracy of D-dimer test for exclusion of venous thromboembolism: a systematic review

Troponin I Measurement: Evolution of a Biomarker Essential for Assessment of Myocardial Injury

Cover Page. The handle holds various files of this Leiden University dissertation

The Rapid D-Dimer Test is a chromatographic immunoassay for the qualitative detection of D-Dimer in human whole blood and plasma.

Comparison of Samples Obtained From 3.2% Sodium Citrate Glass and Two 3.2% Sodium Citrate Plastic Blood Collection Tubes Used in Coagulation Testing

Mouse C-peptide EIA. Cat. No. YII-YK013-EX FOR LABORATORY USE ONLY

Troponin Assessment. Does it Carry Clinical Message? Stefan Blankenberg. University Heart Center Hamburg

Certificate of Analysis

Biomarkers, menopausal hormone therapy and risk of venous thrombosis: The Women's Health Initiative.

Pulmonary Embolism. Pulmonary Embolism. Pulmonary Embolism. PE - Clinical

DetectX. Urinary Creatinine Detection Kit. Catalog Number K002-H1. Sample Types Validated: Human, Monkey, Dog, Rat and Mouse Urine

D-Dimers in the Diagnosis of Pulmonary Embolism

The knowledge and skills involved in clinical audit

Research Article The Use of Computed Tomography of Pulmonary Angiogram in a District Hospital

Assessment of the safety using age adjusted D-dimer to rule out venous thromboembolism in a Swedish Emergency Department

Morinaga Mouse C-peptide ELISA Kit

Emergency physicians commonly measure quantitative

HumaTex CRP. Design Verification. Contents

The annual incidence of venous thromboembolic disease

Stago Newsletter. Volume 5 Issue 2 November 2015

Evaluation of a rapid lateral flow immunoassay (STic Expert HIT) for the diagnosis of heparin-induced thrombocytopenia (HIT)

Correlation of novel cardiac marker

a Laboratory of Hematology, Namur Research Institute for Life Sciences, CHU Received 9 August 2013 Accepted 29 September 2013

GSI Canine IL-5 ELISA Kit-2 Plates DataSheet

Validation Report for the Neogen Fentanyl Kit for ELISA Screening of Whole Blood and Urine Specimens

IMMUNOASSAY PREMIUM PLUS - LEVEL 2 (IA PREMIUM PLUS 2)

DIRECT ENZYMATIC HbA1c ASSAY

NeoSal Oral Fluid Collection System Solutions for Forensic Drug Detection

Biocard. 1. Troponin I

Expression of HIV-1 Markers During Progression of Infection E E E Days Since 1st Bleed

IFLS C-Reactive Protein Data User Guide

FinTest IgG4 Screen 20 ELISA KIT

NIH Public Access Author Manuscript Arch Intern Med. Author manuscript; available in PMC 2013 September 17.

FINAL REPORT HBV Serology External Quality Assessment Scheme

Chapter 5. Recombinant factor VIIa improves clot formation but not fibrinolytic potential in patients with cirrhosis and during liver transplantation

D-dimer and exhaled CO2/O2 to detect segmental pulmonary embolism in

Procine sphingomyelin ELISA Kit

Investor Overview. March 2019

I know my value CoaguChek XS Pro system

Dog Insulin ELISA Kit (TMB)

Instructions for use. TSH rat ELISA. Please use only the valid version of the Instructions for Use provided with the kit AR E-8600

Protein C and protein S levels can be accurately determined within 24 hours of diagnosis of acute venous thromboembolism

Transcription:

ECAT FOUNDATION EXTERNAL QUALITY ASSESSMENT PROGRAMME IN HAEMOSTASIS AND THROMBOSIS D-DIMER EXERCISE 25-2 LABORATORY CODE: 12 ECAT Foundation P.O. Box 2215 231 CE Leiden The Netherlands E-Mail: P.Meijer@ecat.nl Copyright 25

GENERAL INFORMATION This was the second time we used a separate closing date for the D-Dimer module. There are still a significant number of participants who did not retrun their results in time. PLEASE NOTICE THE CLOSING DATE FOR THE D-DIMER MODULE VERY WELL. If you do not return your results in time next exercise, they will be not included into the evaluation. The results of each method used by one or more participants are shown in the part of the report for quantitative methods. However, only methods with at least 1 participants the inter-laboratory variation as well as the Z-score are given. For those methods a Z-score could be calculated for both samples, the relationship between both Z-scores is given in a Z-score plot. A significant number of laboratories did not report in the units indicated in the kit insert of the method. This is especially the case for users of a method expressing their results in Fibrinogen Equivalent Units. Please take notice of the correct selection of the unit for your particular method. For the following labcodes, using the Tinaquant method, it was clear that they had reported their results in DD-units in stead of FEU labcode 389, 417 and 464. Here we have transformed their result to FEU by multiplying the reported result by 2. About 5 participants clearly mixed up their results for the samples 5.22 and 5.23. Before starting data analysis we have corrected for this mistake. Please notice that you report the correct result for each of the test samples. PARTICIPATION Number of participants : 29 Number of responders : 236 Participation rate : 81.4% Comments: There is an increasing number of participants who have returned their results in time. Because for a separate group of German laboratories a wrong closing date was indicated at their report forms we have wait with the evaluation of the results till this date has passed (June 2 th ). To further improve the response rate, please notice carefully the closing date for D- Dimer during the next exercises. PLASMA Sample Description Former used 5.22 5.23 Mixture of pooled patient plasma and pooled plasma of apparently healthy volunteers resulting in elevated Dimer levels. (clearly elevated D-Dimer level) Mixture of pooled patient plasma and pooled plasma of apparently healthy volunteers resulting in elevated Dimer levels. (slightly elevated D-Dimer level) - -

OUTLIERS Sample Labcodes 5.22 128, 351, 362 5.23 362, 464 SEMI-QUANTITATIVE METHOD Semi-Quantitative results (mg/l) <.25.25-.5.51-1. 1.1-2. 2.1-4. 4.1-8. your result Sample 5.7 1 Sample 5.8 1

QUANTITATIVE METHOD SAMPLE 5.22 5 4 3 2 method your result other Liatest (Stago) Tinaquant (Roche) <.125.5 1. 1.5 2. 2.5 3. 3.5 4. Count 1 D-Dimer Plus (DB) AutoDimer (Biopool) Vidas (Biomerieux) D-Dimer (1) D-Dimer (ng/ml D-Dimer) n mean CV range your result Z-score MiniQuant (Trinity/Biopool) 1 1.8 AutoDimer (Trinity/Biopool) 16 1.33 35.3%.9 2.4 Auto D-Dimer (Trinity/Sigma) 1.8 D-Dimer Plus (Dade Behring) 31.19 19.8%.11.29 Dimertest Latex (Dade Behring) 1.1 Dimertest Turbiquant (Dade Behring) 1.32 Dimertest (IL) 5.8.69.87 D-Dimer (ILS-LS) 3.83.55 1.8 D-Dimer (Medirox) 3 1.6 1.3 1.13 Nycocard (Nycomed) 1 1. Dimertest (Ortho) 1 1.95 Other / Unknown 1 2.8 D-Dimer (ng/ml FEU) N mean CV range your result Z-score Vidas (Biomerieux) 62 1.83 7.6% 1.52 2.17 1.79 -.29 Latex D-Dimer (Biomerieux) 1.97 MDA D-Dimer (Biomerieux) 2 1.47 1.41 1.54 Kokusai D-Dimer test 1 3.5 Tinaquant (Roche) 49 3.8 9.1% 2.5 3.52 Latex D-Dimer (Roche) 3 2.6 1.96 2.17 Cardiac Reader (Roche) 1 3.8 Liatest (Stago) 5 2.19 7.8% 1.68 2.62 Asserachrom (Stago) 1 1.94

QUANTITATIVE METHOD SAMPLE 5.23 6 5 4 3 2 method your result other Liatest (Stago) Tinaquant (Roche).5.2.4.6.8 1. 1.2 1.4 1.6 Count 1 D-Dimer Plus (DB) AutoDimer (Biopool) Vidas (Biomerieux) D-Dimer (2) D-Dimer (ng/ml D-Dimer) n mean CV range your result Z-score MiniQuant (Trinity/Biopool) 1.33 AutoDimer (Trinity/Biopool) 16.28 19.3%.22.44 Auto D-Dimer (Trinity/Sigma) 1.11 D-Dimer Plus (Dade-Behring) 3.7 59.2%.1.17 Dimertest Latex (Dade Behring) 1.5 Dimertest Turbiquant (Dade Behring) 1.26 Dimertest (IL) 5.34.2.43 D-Dimer (ILS-LS) 3.28.24.33 D-Dimer (Medirox) 3.26.21.28 Nycocard (Nycomed) 1.6 Dimertest (Ortho) 1.28 Other / Unknown 1.69 D-Dimer (ng/ml FEU) N mean CV Range your result Z-score Vidas (Biomerieux) 62.62 6.9%.51.73.63.23 Latex D-Dimer (Biomerieux) 1.26 MDA D-Dimer (Biomerieux) 2.63.59.67 Kokusai D-Dimer test 1 1.1 Tinaquant (Roche) 49.94 14.%.66 1.2 Latex D-Dimer (Roche) 3.76.67.82 Cardiac Reader (Roche) 1.83 Liatest (Stago) 5.74 11.2%.52.92 Asserachrom (Stago) 1.82

QUANTITATIVE METHOD 6 laboratory 12 Z-score D-dimer sample 2 4 2-2 -4 method Liatest (Stago) Tinaquant (Roche) D-Dimer Plus (DB) AutoDimer (Biopool) Vidas (Biomerieux) -6-6 -4-2 2 4 your result Z-score D-dimer sample 1. The Z-score plot shows the relationship between the Z-scores of both samples used in this survey. In this plot only the Z-scores of methods with at least 1 participants are included. The relationship of both Z-scores gives you an indication if your deviation from the mean value of your particular method is caused by systematic and/or random errors.