Streamlined workflow for review and analysis of oncology patients

Similar documents
MRI to fit your planning. Philips Panorama HFO Oncology Configuration

Liver metastases: treatment planning. PJ Valette

IntelliSpace Breast. Mammography solutions. Manage your breast review environment

Mobile radiography realizes its full potential

High performance ultrasound

Keeping pace with imaging innovation

Welcome to the RECIST 1.1 Quick Reference

Radiographic Assessment of Response An Overview of RECIST v1.1

The first MR with IQ. Philips Intera 1.5T With SmartExam

Computer based delineation and follow-up multisite abdominal tumors in longitudinal CT studies

A new way of thinking. Philips Sparq emergency medicine ultrasound system

For a legacy that lives large: Think Big. Philips CT Big Bore. Computed tomography

RECIST 1.1 Criteria Handout. Medical Imaging. ICONplc.com/imaging

High performance compact ultrasound

Versatile, affordable ultrasound. Philips HD6 ultrasound system. The print quality of this copy is not an accurate representation of the original.

Fast and easy diagnostic imaging from head to toe

EP lab robotic support

Expanding therapy options for

Assessing Arrhythmia Performance ST/AR Algorithm

Applying the New irecist Guidelines Radiologic and Clinical Trial Considerations

MEASUREMENT OF EFFECT SOLID TUMOR EXAMPLES

Update on RECIST and Staging of Common Pediatric Tumors Ethan A. Smith, MD

High performance compact ultrasound

The next generation of prostate care

The intelligent solution. System One Sleep Therapy System uses advanced intelligence to deliver excellent care while making patient management easy

Making the difference with Live Image Guidance

Radiation Oncology. The conf ident path to treatment Philips Radiation Oncology Solutions

Changing your idea of clinical performance. Philips HD15 PureWave ultrasound system for echocardiography

Radiologic assessment of response of tumors to treatment. Copyright 2008 TIMC, Matthew A. Barish M.D. All rights reserved. 1

Making the difference with Live Image Guidance

Step up to the iu22 The key reasons are now even more compelling

How to evaluate tumor response? Yonsei University College of Medicine Kim, Beom Kyung

One intelligent solution

Emergency Care Clinical Data Transmission Networks

Volumetric Functional MRI Criteria for Assessing Tumor Response

Advancing treatment of cancer through imaging technologies Hans Hofstraat

MRI-PET: Oncologic Applications

Ingenia MR-RT. MR Systems. The comprehensive MR-sim solution to fit your planning

A simple solution for your complex patients

Reliable versatility. Philips HD5 ultrasound system

ABAS Atlas-based Autosegmentation

Evaluation of Lung Cancer Response: Current Practice and Advances

FreeWave upgrade enables faster, more powerful imaging

Imaging Systems. Gene Saragnese EVP and GM Imaging Systems

Comparison of RECIST version 1.0 and 1.1 in assessment of tumor response by computed tomography in advanced gastric cancer

Feasibility evaluation of dual axis rotational angiography (XperSwing) in the diagnosis of coronary artery disease

Leveraging Standards for Effective Visualization of Early Efficacy in Clinical Trial Oncology Studies

Clinically focused workflow with unique ability to integrate fmri, DTI, fiber tracks and perfusion in a single, multi-layered 3D rendering

Raising diagnostic confidence

Certainty. lives in layers. Philips IQon Spectral CT. Computed tomography

Standardize and Optimize. Trials and Drug Development

Simplifying liver assessment in internal medicine

One intelligent solution

Xcelera version comparison of features and functionality

A new era in premium ultrasound

8/10/2016. PET/CT Radiomics for Tumor. Anatomic Tumor Response Assessment in CT or MRI. Metabolic Tumor Response Assessment in FDG-PET

Prof. Dr. NAGUI M. ABDELWAHAB,M.D.; MARYSE Y. AWADALLAH, M.D. AYA M. BASSAM, Ms.C.

Paradigm shift - from "curing cancer" to making cancer a "chronic disease"

Ultrasound. Sparq. A new way of. thinking. Philips Sparq critical care ultrasound system

Radiological evaluation, with RECIST criteria, of treatment response of non-microcytic lung cancer. Routine follow-up.

Nodule Detection process: 1. Click on the patient study to be loaded 2. Click the drop down arrow next to the analysis button and select LNA

Natural performance. Introducing the BiPAP A30 - because ease of use and therapy efficacy are key to patient well-being

Early defibrillation programs for the workplace. Give your workplace the power to save a life

PharmaSUG 2018 Paper AD-02

Pocket Guide. System One REMstar Pro and REMstar Auto

Introduction to REM-NM Radiation Exposure Monitoring for Nuclear Medicine. Jeff Pohlhammer, Charles Smith

Advancing critical clinical decisions

Somnolyzer 24x7. Addressing cost pressures in the sleep lab

Ultrasound. Computed tomography. Case studies. Utility of IQon Spectral CT in. cardiac imaging

A new class of compact ultrasound. Philips CX50 CompactXtreme ultrasound system

Pioneering the future of general imaging.

Premium performance compact ultrasound. Philips CX50 CompactXtreme ultrasound system

Enhancing diagnostic confidence in the technically difficult patient

Radiological staging of lung cancer. Shukri Loutfi,MD,FRCR Consultant Thoracic Radiologist KAMC-Riyadh

Innovative Lung Cancer Screening Solution

An excellent fit to expand the imaging center, Prodiva 1.5T

Ingenuity TF PET/CT. Comfort and quality care in one. Your PET/CT scan with Philips Ingenuity TF PET/CT

Assessment of Efficacy and Immune Related RECIST criteria

Comparison of Radiological Criteria (RECIST - MASS - SACT -Choi) in Antiangiogenic Therapy of Renal Cell Carcinoma

Ultrasound. Sparq. A new way of. thinking. Philips Sparq emergency medicine ultrasound system

Elastography in the. technically difficult patient. EPIQ ultrasound system. Ultrasound

Meeting the big challenge of little faces. Philips Respironics pediatric patient interfaces for noninvasive ventilation

RECIST 1.1 and SWOG Protocol Section 10

Full ultrasound breast volumes. Faster scans. Streamlined workflow. ACUSON S2000 Automated Breast Volume Scanner. Answers for life.

3D Total Breast Ultrasound

Multimedia-enhanced Radiology Reports: Concept, Components, and Challenges 1

Automated Volumetric Cardiac Ultrasound Analysis

Chapter 6. Hester Gietema Cornelia Schaefer-Prokop Willem Mali Gerard Groenewegen Mathias Prokop. Accepted for publication in Radiology

Field Strength. Regional Perfusion Imaging (RPI) matches cerebral arteries to flow territories

Biomarkers and the Future of. John R. Votaw CBIS 5 th Year Anniversary Celebration/Look to the future February 8, 2013

Case Studies. Any other questions? medicom.us

SWOG ONCOLOGY RESEARCH PROFESSIONAL (ORP) MANUAL RESPONSE ASSESSMENT LYMPHOMA CHAPTER 11B REVISED: SEPTEMBER 2016

GUIDELINES FOR CANCER IMAGING Lung Cancer

UVM brain MRI protocols upgraded with latest methods

Using MRI only in prostate cancer radiotherapy workflow

BRAINLAB ELEMENTS RADIOTHERAPY PLANNING

ROLE OF PET-CT IN BREAST CANCER, GUIDELINES AND BEYOND. Prof Jamshed B. Bomanji Institute of Nuclear Medicine UCL Hospitals London

MOSAIQ TM Image Enabled EMR. managing the spectrum of cancer care. Filmless and paperless workflow Universitätsklinikum Mannheim

Transcription:

Streamlined workflow for review and analysis of oncology patients Philips IntelliSpace Portal Multi-modality Tumor Tracking application (MMTT) Ekta Dharaiya, MS, Philips Healthcare, Cleveland, OH Cancer is one of the leading causes of death in the world and costs more in productivity and lost life than any other illness, according to a new report published by the American Cancer Society. 1 With the increase in the aging population and changes in lifestyle behavior, the incidence of cancer is on the rise globally (economically developed and developing countries). Imaging modalities (X-ray, CT, MR, PET, US) play a significant role in detection, diagnosis, staging and monitoring of cancer and also in image-guided treatments like RF ablation. Diagnostic oncology (tumor detection, diagnosis, and monitoring) related scanning account for a majority of all CT procedure volume. Introduction of new drugs and therapies also require continuous and frequent monitoring of the patient to analyze their influence and effect.

Post-processing of oncology (CT, PET/CT, and MR) image datasets can pose a major challenge for radiology and oncology staff. It often requires the maneuvering and analysis of a significant amount of data due to multiple follow-up studies. The user has to: Load multiple patient examinations for side-by-side comparisons to the baseline scan and nadir scan (smallest criteria recorded since the treatment started) in case of new progression. These datasets often include exams from multiple imaging modalities. Scroll through the numerous images of large datasets to identify and locate the tumors and lymph nodes for follow-up analysis. Measure the size of the tumors and lymph nodes including long axis and short axis diameters, as well as other quantitative parameters such as HU values. Calculate tumor burden measurements based on RECIST and WHO criteria and assess response to treatment. The IntelliSpace Portal Tumor tracking application supports datasets from different imaging modalities including CT, MR, and PET/CT. The above image is of a 62-year-old female, history of lung cancer. Large lesion segmented in right upper lobe. Lesion statistics obtained for PET (SUV) and CT (HU). Definitions Response Evaluation Criteria in Solid Tumors (RECIST) A published guideline used to assess the change in size (maximum diameter in 2D plane) of solid tumors and lymph nodes in response to therapy. The response is categorized into: Complete Response (CR): disappearance of all target lesions Partial Response (PR): 30% decrease in sum of diameters of all target lesions Stable Disease (SD): No change in the size of the lesions Progressive Disease (PD): 20% or absolute 5 mm increase in sum of diameters of target lesions The user identifies the target lesions on the baseline examination. Target lesions should be selected on the basis of their size (lesions with the longest diameter) and their suitability for accurate repeated measurements (either by imaging techniques or clinically). World Health Organization (WHO) The WHO criteria defined shrinkage of a tumor as the decrease in the product of the largest perpendicular diameters in the largest slice of the tumor on a scan. The MMTT application can also be used to analyze MR data. In this case, a diffusion dataset is used to assess the size and activity of a lesion. The Apparent Diffusion Coefficient (ADC) values don t change over the time period, whereas the size of the lesion appears to increase over the time frame. The Multi-modality Tumor Tracking application (MMTT) of Philips IntelliSpace Portal provides the tools to help simplify the review and analysis of multi-modality oncology datasets for tumor detection and monitoring. The application has semi-automatic segmentation tools to facilitate 2D and 3D segmentation of tumors and lymph nodes. For instance, it allows the user to make quick bi-dimensional measurements using 2D measurements tools as shown in Figure 2. The application also enables graphical tracking of the size of the tumor across the different time points (Figure 3). After the measurements are completed, it automatically performs the RECIST and WHO calculations. 2

Current workflow for evaluation of oncology cases Time spent in manually identifying the tumors in follow-up datasets Manual measurements of tumor parameters Manual data entry for calculation of tumor burden based on RECIST/WHO criteria MMTT application The Multi-modality Tumor Tracking application supports loading and comparison of patient datasets from different imaging modalities such as CT, MR, PET/CT, and SPECT/CT. The application has dedicated tools for segmentation and measurements of tumors for the different imaging modalities. Easy follow-up assessment Oncology scans require frequent comparison with previous datasets, to identify tumors and make measurements. The application simplifies assessment of follow-up datasets by: Allowing loading of up to eight previous and current datasets of the patient Allowing simultaneous side-by-side comparisons of four previous and current datasets of the patient Allowing loading of saved results from all previous datasets of the patients, if the user has saved results (segmented tumors and measurements) from analysis of previous datasets Automatic registration of the current and previous datasets (CT to CT) Reduces the need to scroll through the datasets in order to locate the target tumors, and this improves workflow Segmentation tools The MMTT application offers semi-automatic segmentation tools for 3D volumetric segmentation of tumors and lymph nodes. It also offers simplified 2D measurement tools for quick bi-dimensional measurement of tumors and lymph nodes in cases where 3D volumetric segmentation is not needed. Semi-automatic segmentation of tumors and lymph nodes to measure long axis and short axis diameter, volume, Hounsfield Unit (HU) values, and SUV values Semi-automated measurements are more reproducible than manual measurements made by radiologists 3

Assessing response treatment Response to treatment is evaluated by making calculations defined by standard criteria, (e.g., RECIST and WHO) using measured tumor parameters. Manual calculation of these parameters and criteria could be a time-consuming and tedious task. The MMTT application allows Automatic calculation of tumor burden based on RECIST/WHO criteria Measurements from all loaded time points and results are displayed in a table Visual tracking of tumor parameters on a graph Display of histogram of the HU and SUV values of segmented tumors and lymph nodes for all the time points loaded into the application Measurement of ADC values of the tumor over different time points, using diffusion weighted MRI Saving and reporting of results The MMTT application allows Ability to save bookmarks to allow for easy review of results by the referring physician or radiologist Ability to save results: segmented lesions, registration of the datasets, measurements table, graphical tracking of information from the application for future reference and analysis Generation of an application-specific report with key images of all the segmented lesions, measurements table, graph display of the selected parameters, and any other images selected by the user. The user can customize the report, add more images, text, etc., based on their own requirements Ability to save the report on PACS or easy sharing with the referring physicians Real time communication with oncologists IntelliSpace Portal offers an integrated medical networking platform enabling radiologists to communicate and collaborate. IntelliSpace Portal has many integrated features such as reporting, bookmarks, and collaboration tools. Together these provide the ability to access, create, and communicate actionable information throughout the institution. These tools allow high-quality collaboration between radiologists and referring physicians at virtually any onsite or remote location. The collaborative tools are Internetbased for real time interaction and communication between radiologists and oncologists. The collaboration tool enables radiologists to discuss a case and share information (e.g., tumor parameters, tumor burden, key images) with oncologists to improve patient care. Streamlined workflow with MMTT 4

The new MMTT application from Philips has really made our lives easier. We do not have to spend time pulling out the measurements from the radiologists reports, entering in an Excel spreadsheet, and calculating the RECIST measurements. This all is done automatically by the application; we can now just add the report or a screenshot to the patient history at our end. This is great! Debra Duvall, RN, BSN Clinical Research Coordinator St. Francis Cancer Research Foundation Case study (Courtesy: Franciscan Saint Francis Health, Indianapolis, IN) A patient with prior history of stroke, hypercholesterolemia and hypertension was diagnosed with renal cell carcinoma stage T1bN2M0. The patient had ten follow-up CT scans over a period of two years. The primary tumor in the kidney remained stable over the course of therapy; however, the patient was taken off the therapy due to increase in toxicities. The MMTT application allows loading of results from all the scans of the patient and data from eight scans (Figure 1). Automatic registration tools align the data automatically for easy identification of target lesions in follow-up datasets (Figure 1). Semi-automatic segmentation tools allow volumetric segmentation of the data. 2D tools allow quick bi-dimensional measurements (Figure 2). Measurements from the lesion can be tracked on the graph or displayed in the table (Figure 3). RECIST tumor burden is calculated automatically (Figure 3). Figure 1. The MMTT application allows loading of eight multi-modality datasets of the patient. The loaded datasets can be visualized on a timeline. The application allows simultaneous comparison of four datasets. The loaded CT datasets are automatically registered with each other using Automatic Registration. 5

The MMTT application has really helped us simplify and streamline our workflow. It has all the necessary tools for a complete oncologic evaluation of the dataset. This application is a real time-saver for the radiologists. J. Louis Rankin, BS, RT(R)(MR)(PET), 3D Lab Technical Coordinator Imaging Services, Franciscan St. Francis Health Figure 2. The application allows volumetric 3D segmentation of lesions in the loaded datasets. The application allows simple bi-directional measurements of lesions in the loaded datasets. lume for nd of Vo wth tre the gro shows patient. ph below The gra datasets of the evaluated Lymph Nodes Head & Neck, Regions: all the lesions Thorax, rently in the cur Abdomen, Pelvis Multi-modal ity Tumor Tra Report cking Other: of Procedure previous exams and compared with 21 dar y) 2011 on Brilliance 64 CT on con Mar was performed 22 Dec 2010; 2011 (Se A CT examination Oct 2010; CT on 21 Mar med on CT on 1 the Patient perfor dary) L1 0 (Secon Dec 201 Pati ent Informa 22 These tion t of the patient. nted in the datase and segme Patient us datasets. s was identified previo tumor W, track A total of 1 lesion and compared to the Name: ing case Patie red 2V nt ID: lesions were measu Age: 59 years Gender: Date of Birth Female : Study Date: Accession Num 23 May 2011 ber: Findings ry) 0 (Prima 1 Oct 201 222 13 Indications Initial diagnosis Lesion Characterizatio ents: Comm 23 May y) condar 2011 (Se Lesion n y) condar Date (Se Follow-up y) condar Date (Se Primary Metastases Other: trend of shows the growth The graph below ts of the patient. evaluated datase Volume for all the tly lesions in the curren Exam Summar tumor W, y y 13 ns 222Lesio 13onl 222use 2 Vare for reference reference use only trackin e 2 Vg caseage W,cas s * Image are for tumor Orgasns: * Im Lung, Liver tracking, Pancreas, Other: tumor W, track Kidney, Abdomen, Bones, Head ing case 2 V 222 13 * Images are for reference use only Figure 3. The application displays all the calculated parameters for the Figure 4. The MMTT application supports sending of all the analysis segmented lesions in a table, along with the completely automatic RECIST including the results table, graph, and key images to the report. calculations. The selected measurement of the tumors can also be tracked on a graph. 6

The author would like to acknowledge the following for their input: Jeffrey Yanof Kevin Buchan Philippe Coulon Sigal Amin-Spector Thomas Naypauer References 1. Garcia M, Jemal A, Ward EM, Center MM, Hao Y, Siegel RL, Thun MJ. Global Cancer Facts & Figures 2007. Atlanta, GA: American Cancer Society, 2007. 2. Zhao B, James LP, Moskowitz C, Ginsberg M, Qin Y, Riely G, et al. Evaluating Variability in Tumor Measurements from Same-day Repeat CT Scans of Patients with Non-small Cell Lung Cancer. Radiology, 2009:252;263-272. 7

Philips Healthcare is part of Royal Philips Electronics How to reach us www.philips.com/healthcare healthcare@philips.com Asia +49 7031 463 2254 Europe, Middle East, Africa +49 7031 463 2254 Latin America +55 11 2125 0744 North America +1 425 487 7000 800 285 5585 (toll free, US only) Please visit www.philips.com/intellispace 2011 Koninklijke Philips Electronics N.V. All rights are reserved. Philips Healthcare reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. Printed in The Netherlands. 4522 962 79521 * NOV 2011