Lesson 03: Sound Wave Propagation and Reflection. This lesson contains 15 slides plus 14 multiple-choice questions.

Similar documents
Ultrasonic Testing Level I:

The Physics of Ultrasound. The Physics of Ultrasound. Claus G. Roehrborn. Professor and Chairman. Ultrasound Physics

Basic Ultrasound Physics Board Review Questions

Dr Emma Chung. Safety first - Physical principles for excellent imaging

ULTRASOUND. OB/Gyn (Core) Ultrasound PIEZOELECTRIC EFFECT. Principles of Ultrasound Physics and Instrumentation. Nathan Pinkney, BS, CDOS

Ultrasound Physics & Terminology

Principles of Ultrasound. Cara C. Prideaux, M.D. University of Utah PM&R Sports Medicine Fellow March 14, 2012

ULTRASOUND IMAGING EE 472 F2018. Prof. Yasser Mostafa Kadah

Diploma of Medical Ultrasonography (DMU) Physical Principles of Ultrasound and Instrumentation Syllabus

Chapter 14. Imaging Artifacts

Ultrasound Principles cycle Frequency Wavelength Period Velocity

The table below shows the density and velocity of waves in two different substances. Density / kg m 3 Velocity / m s 1

Ultrasound Physics and Knobology Alan Macfarlane. Consultant Anaesthetist Glasgow Royal Infirmary

Preamble (disclaimer)

Sound in medicine. CH.12. Dr.Rajaa أ.م.د. رجاء سهيل جنم جامعة تكريت كلية طب االسنان. General Properties of Sound

Ultrasound Physics & Doppler

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion

Physical Principles of Ultrasound

Lesson 07: Ultrasound Transducers. This lesson contains 73 slides plus 16 multiple-choice questions.

Basic Physics of Ultrasound in Transesophageal Echocardiography

Introduction to Biomedical Imaging

Point-of-Care Ultrasound: An Introduction

Basic Physics of Ultrasound and Knobology

DIGITAL IMAGE PROCESSING IN ULTRASOUND IMAGES

1 Fundamentals. Basic Definitions and Physics Principles. Fundamentals

4.17. RESEARCHING MODELS WITH AN ULTRASONIC ECHOSCOPE

Ultrasound: Past and Present. Lecturer: Dr. John M Hudson, PhD

What is Ultrasound? Resolution Image production Attenuation Imaging modes Ultrasound artifacts... 7

Chapter 2 Pitfalls in Musculoskeletal Ultrasound

Strain Assessment in Echo

Ultrasound in Anesthesia: Applying Scientific Principles to Clinical Practice

Ultrasonic Testing of Composite Structures

Chapter 1. Principles of medical ultrasound. Overview. Background history: first steps to the piezo-electric effect.

4.17. RESEARCHING MODELS WITH AN ULTRASONIC ECHOSCOPE

Ultrasound guidance in regional anesthesia has

Basic of Ultrasound Physics E FAST & Renal Examination. Dr Muhammad Umer Ihsan MBBS,MD, DCH CCPU,DDU1,FACEM

An Overview of Ultrasound Testing For Lesion Detection in Human Kidney

Terminology Tissue Appearance

Supplement (videos)

TG-128: Quality Assurance for Prostate Brachytherapy Ultrasound

Ultrasound. Principles of Medical Imaging. Contents. Prof. Dr. Philippe Cattin. MIAC, University of Basel. Oct 17th, 2016

Diagnostic Ultrasound. Sutiporn Khampunnip, M.D.

CONTENTS. Test Number cpd Tanya Reynolds (Nat. Dip. Diag. Rad., B. Tech. Diag. Rad., B. Tech. Ultrasound)

1. Fig. 1 shows data for the intensity of a parallel beam of X-rays after penetration through varying thicknesses of a material

Ultrasonic Testing. Basic Principles

Thyroid Ultrasound Physics and Doppler

Descriptions of NDT Projects Fall 2004 October 31, 2004

Underwater Acoustic Measurements in Megahertz Frequency Range.

Linear Ultrasonic Wave Propagation in Biological Tissues

Employer s Unit of Competence Ultrasonic testing of materials, products and plant

Ultrasound Measurements and Non-destructive Testing Educational Laboratory

Non-Destructive Inspection of Composite Wrapped Thick-Wall Cylinders

Roaa M.Hussein Professor, Department of Physics, College of Science, Ramadi, Iraq. Abstract:

Application of Phased Array Radar Theory to Ultrasonic Linear Array Medical Imaging System

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion

Breast Imaging Essentials

Principles of echocardiography for the anesthesiologist.

Emergency Medicine Interest Group (EMIG) 2016

Performance of phased array and conventional ultrasonic probes on the new ISO reference block

Pulse-Echo Ultrasound Imaging. Resolution in Ultrasound Imaging. Doppler Ultrasound. Resolution vs Penetration. Medical Imaging (EL582/BE620/GA4426)

What is Ultrasound? What is Ultrasound? B A. Basic Principles of Ultrasound. Basic Principles of Ultrasound. Basic Principles of Ultrasound

Knobology for Dummies

Ultrasonic Testing courses at DGZfP Education and Training Ltd

Ultrasonography of the Neck as an Adjunct to FNA. Nicole Massoll M.D.

COWLEY COLLEGE & Area Vocational Technical School

Critical Care Ultrasound Study Notes

Ultrasonic Testing (UT) Technique

Table of contents. Foreword. Preface. 1 Introduction Historical Perspective 00

WELCOME! Introduction to Bedside Ultrasound

Physics. Norman McDicken Tom Anderson CHAPTER ULTRASOUND. Ultrasound Propagation

HSC Physics. Module 9.6. Medical Physics

Physical Principles of Ultrasound

Introduction to Ultrasound Guided Region Anesthesia

TASK: S-2 DISTORTION MEASUREMENT AND BIOMECHANICAL ANALYSIS OF IN VIVO LOAD BEARING SOFT TISSUES

Medical Imaging. Ultrasound Imaging

ADVANCEMENTS IN NON DESTRUCTIVE TESTING

Exam Practice Guide. Units 1 & 2 Physics: Detailed Study 5 - Investigations: Medical physics Examination Questions

Skin Characterization with High-Frequency Ultrasound

COURSE DESCRIPTION FOR NONDESTRUCTIVE TESTING

Concepts of Imaging and Knobology

ULTRASOUND NOMENCLATURE

The Evolution and Benefits of Phased Array Technology for the Every Day Inspector

Feng Xiujuan National Institute of Metrology (NIM),China

ASCeXAM / ReASCE. Practice Board Exam Questions Monday Morning

Chapter 3 Physical Principles of Ultrasound of the Male Genitalia

DIAGNOSTIC TECHNIQUE OF ABNORMALITIES IN BALL BEARINGS WITH AN ULTRASONIC METHOD

VISUALIZATION OF TRANSDUCER-PRODUCED SOUND FIELDS IN SOLIDS

Flip Chips and Acoustic Micro Imaging: An Overview of Past Applications, Present Status, And Roadmap for the Future

Ultrasonic Thickness Procedure Pulse-Echo Thickness Gage TABLE OF CONTENTS. 1.0 Introduction Reference Documents Summary of Practice 2

Evaluation of the Quality of Thick Fibre Composites Using Immersion and Air- Coupled Ultrasonic Techniques

Chapter 3. Sonographic Image Interpretation

Endobronchial Ultrasound

RPVI Exam Review ecourse

FORMING SCREEN EFFECT ON ULTRASONIC BEAM FIELD

8/15/2011. Quantitative Ultrasound Imaging: A Historical Perspective. Motivation. Motivation & Applications. Motivation & Applications

Basic Training Programme. 16 Februrary 2018, ROTTERDAM. Pre and Post-Course Test Answers

CSB 046 Complementary Imaging Techniques

US Artifacts 1 EDUCATION EXHIBIT. Myra K. Feldman, MD Sanjeev Katyal, MD Margaret S. Blackwood, MS

The 2 nd Cambridge Advanced Emergency Ultrasound Course

COWLEY COLLEGE & Area Vocational Technical School

Transcription:

Lesson 03: Sound Wave Propagation and Reflection This lesson contains 15 slides plus 14 multiple-choice questions. Accompanying text for the slides in this lesson can be found on pages 8 through 14 in the textbook:

Sound Wave Propagation and Reflection

PROPAGATION

PULSE-ECHO

RANGE EQUATION: (in tissue) TIME TO THE REFLECTOR (ONE WAY) DISTANCE TO THE REFLECTOR (ONE WAY) ROUND TRIP TIME ROUND TRIP DISTANCE 6.5 µs 10 mm (1 cm) 13 µs 20 mm (2 cm) 5 µs 7.7 mm (0.77 cm) 10 µs 15.4 mm (1.54 cm)

PULSE-ECHO FORMULAS Pulse Repetition Period = 1 Pulse Repetition Frequency PRF PRP 1000 Hz 1/1000 sec (0.001 sec) 2000 Hz 1/2000 sec (0.0005 sec) 4000 Hz 1/4000 sec (0.00025 sec)

PULSE-ECHO FORMULAS Duty Factor = Pulse Duration Pulse Repetition Period PRF PRP PULSE DURATION DUTY FACTOR Increase Decrease Increase Decrease Increase Decrease Increase Increase Decrease Decrease

ACOUSTIC IMPEDANCE: Acoustic Impedance = Density x Velocity DENSITY VELOCITY ACOUSTIC IMPEDANCE Increase Increase Decrease Decrease Increase Increase Decrease Decrease

ACOUSTIC IMPEDANCE (Rayls) Air 400 Fat 1,380,000 Water 1,430,000 Soft Tissue 1,630,000 Muscle 1,700,000 Bone 7,800,000

INTERFACE MATERIALS & ECHO STRENGTH Soft Tissue to Muscle - Weak (1%) Fat to Soft Tissue Weak (1%) Soft Tissue to Bone - Medium (50%) Blood to Plaque Medium (50%) Soft Tissue to Air - Very Strong (100%)

SAGITTAL - LIVER, RIGHT KIDNEY ACOUSTIC SHADOW: THE RESULT OF A STRONG REFLECTION FROM A GALLSTONE

ACOUSTIC COUPLANT

SPECULAR REFLECTION Small change or no change in velocity With i normal or oblique, t indicates no refraction

SPECULAR REFLECTION Large increase in velocity With i oblique, refraction is present

SPECULAR REFLECTION Large decrease in velocity With i oblique, refraction is present

SAGITTAL - LIVER, RIGHT KIDNEY N = non-specular reflector S = specular reflector 1 = diaphragm 2 = kidney

Answers to the following FOURTEEN practice questions were derived from material in the textbook:

Question 1 A range of pulse repetition frequencies in a pulse-echo ultrasound system could be: 2,000 Hz to 20,000 Hz 20,000 Hz to 200,000 Hz 1,200 Hz to 2,000 Hz 2 MHz to 20 MHz Page 9

Question 1 A range of pulse repetition frequencies in a pulse-echo ultrasound system could be: 2,000 Hz to 20,000 Hz 20,000 Hz to 200,000 Hz 1,200 Hz to 2,000 Hz 2 MHz to 20 MHz Page 9

Question 2 If the number of cycles in a pulse is reduced, the spatial pulse length increases the period increases the duty factor is smaller the bandwidth is decreased Pages 6, 7, and 9

Question 2 If the number of cycles in a pulse is reduced, the spatial pulse length increases the period increases the duty factor is smaller the bandwidth is decreased Pages 6, 7, and 9

Question 3 Damping in a transducer: reduces the transducer's resonant frequency increases the number of cycles in a pulse causes poor axial and lateral resolution reduces the number of cycles in a pulse Pages 5, 6, 7, and 9

Question 3 Damping in a transducer: reduces the transducer's resonant frequency increases the number of cycles in a pulse causes poor axial and lateral resolution reduces the number of cycles in a pulse Pages 5, 6, 7, and 9

Question 4 The distance to a target is doubled. The total time for a pulse to travel to the target and back is: 4 times 2 times 8 times halved Page 8

Question 4 The distance to a target is doubled. The total time for a pulse to travel to the target and back is: 4 times 2 times 8 times halved Page 8

Question 5 If ultrasound energy leaves a transducer and travels through a large amount of fat and then encounters a reflector, the echo will appear on the display: to the right of where it should more superficial than it should deeper than it should to the left of where it should Pages 2 and 8

Question 5 If ultrasound energy leaves a transducer and travels through a large amount of fat and then encounters a reflector, the echo will appear on the display: to the right of where it should more superficial than it should deeper than it should to the left of where it should Pages 2 and 8

Question 6 The reason most ultrasound systems are calibrated at 1540 meters per second is because: 1540 meters per second is the average speed of sound in the patient 1540 meters per second is the speed of sound most often encountered in a patient 1540 meters per second is the maximum speed of sound in a patient 770 meters per second is the average speed of sound in a patient Pages 2 and 8

Question 6 The reason most ultrasound systems are calibrated at 1540 meters per second is because: 1540 meters per second is the average speed of sound in the patient 1540 meters per second is the speed of sound most often encountered in a patient 1540 meters per second is the maximum speed of sound in a patient 770 meters per second is the average speed of sound in a patient Pages 2 and 8

Question 7 Which ultrasound system parameter is affected by variations in the speed of sound? pulse repetition frequency pulse repetition period distance accuracy duty factor Page 8

Question 7 Which ultrasound system parameter is affected by variations in the speed of sound? pulse repetition frequency pulse repetition period distance accuracy duty factor Page 8

Question 8 With an oblique angle of incidence at a non-specular reflector: it is not likely that an echo will return to the transducer Rayleigh scattering is not possible it is possible that an echo will return to the transducer the transmission coefficient will exceed 100% Pages 12, 13, and 14

Question 8 With an oblique angle of incidence at a non-specular reflector: it is not likely that an echo will return to the transducer Rayleigh scattering is not possible it is possible that an echo will return to the transducer the transmission coefficient will exceed 100% Pages 12, 13, and 14

Question 9 If the velocities of sound in the two materials that form an interface are NOT equal, the reflection coefficient will exceed 100% the reflected angle will be greater than the incident angle refraction may occur if the incident angle is oblique the incident angle will be greater than the reflected angle Pages 12 and 13

Question 9 If the velocities of sound in the two materials that form an interface are NOT equal, the reflection coefficient will exceed 100% the reflected angle will be greater than the incident angle refraction may occur if the incident angle is oblique the incident angle will be greater than the reflected angle Pages 12 and 13

Question 10 The redirection of sound energy in many directions as a result of a rough boundary between two media is: shadowing specular reflection scattering refraction Page 14

Question 10 The redirection of sound energy in many directions as a result of a rough boundary between two media is: shadowing specular reflection scattering refraction Page 14

Question 11 If the density is the same in materials A and B, but the speed of sound in material B is 10% greater than the speed of sound in material A, The acoustic impedance in B is 10% greater than the acoustic impedance in A The sound velocity in A is 10% higher than the propagation speed in B The acoustic impedance in A is equal to the acoustic impedance in B The acoustic impedance in A is 10% higher than the acoustic impedance in B Page 10

Question 11 If the density is the same in materials A and B, but the speed of sound in material B is 10% greater than the speed of sound in material A, The acoustic impedance in B is 10% greater than the acoustic impedance in A The sound velocity in A is 10% higher than the propagation speed in B The acoustic impedance in A is equal to the acoustic impedance in B The acoustic impedance in A is 10% higher than the acoustic impedance in B Page 10

Question 12 As the impedances of the two media forming an interface become vastly different, the: transmission increases reflection increases bandwidth increases refraction increases Pages 10 and 11

Question 12 As the impedances of the two media forming an interface become vastly different, the: transmission increases reflection increases bandwidth increases refraction increases Pages 10 and 11

Question 13 A typical reflection coefficient from soft tissue interfaces could be in the range of: 75% 1% 20% 50% Page 11

Question 13 A typical reflection coefficient from soft tissue interfaces could be in the range of: 75% 1% 20% 50% Page 11

Question 14 Matching layers in a transducer: improve axial resolution determine the operating frequency provide greater efficiency of sound transmission from the transducer to the patient improve lateral resolution Page 12

Question 14 Matching layers in a transducer: improve axial resolution determine the operating frequency provide greater efficiency of sound transmission from the transducer to the patient improve lateral resolution Page 12

END OF LESSON 03 For information on the accompanying textbook, visit the Website: www.sonicorinc.com