Dual Energy CT Aortography: Can We Reduce Iodine Dose??

Similar documents
Dual Energy Spectral CT of Focal Liver Lesions in Advanced Cirrhosis: Early Experience

Dual-Energy CT: The Technological Approaches

Dual Energy CT of the Liver

8/3/2016. Consultant for / research support from: Astellas Bayer Bracco GE Healthcare Guerbet Medrad Siemens Healthcare. Single Energy.

Dual-Energy CT Applications in Radiation Therapy

Customizing Contrast Injection for Body MDCT: Algorithmic Approach

Comparison of gastric vascular anatomy by monochromatic and polychromatic dual-energy spectral computed tomography imaging

Liver, Liver Fat, Fibrosis and HCC Screening with DECT

To Shield or Not to Shield? Lincoln L. Berland, M.D.

Ultrasound. Computed tomography. Case studies. Utility of IQon Spectral CT in. cardiac imaging

Fused monochromatic imaging acquired by single source dual energy CT in hepatocellular carcinoma during arterial phase: an initial experience

CT angiography techniques. Boot camp

Gemstone Spectral Imaging quantifies lesion characteristics for a confident diagnosis

How do the Parameters affect Image Quality and Dose for Abdominal CT? Image Review

An Introduction to Dual Energy Computed Tomography

Vascular CT Protocols

Ultralow Dose Chest CT with MBIR

Managing Radiation Risk in Pediatric CT Imaging

Biomarkers and the Future of. John R. Votaw CBIS 5 th Year Anniversary Celebration/Look to the future February 8, 2013

Optimal Monochromatic Energy Levels in Spectral CT Pulmonary Angiography for the Evaluation of Pulmonary Embolism

Dual-Energy 101: Principles, Methods and Dose

True Dual Energy. Dr. Stefan Ulzheimer, Siemens Healthcare GmbH. DEfinitely Siemens

Low Dose Era in Cardiac CT

Translating Protocols Across Patient Size: Babies to Bariatric

CT of the chest with model-based, fully iterative reconstruction: comparison with adaptive statistical iterative reconstruction

SPECIFIC PRINCIPLES FOR DOSE REDUCTION IN HEAD CT IMAGING. Rajiv Gupta, MD, PhD Neuroradiology, Massachusetts General Hospital Harvard Medical School

Automated CT Protocol Design Advantages and Pitfalls of Algorithm-Based Technique Selection in Pediatrics. Disclosures 7/22/2014. Learning Objectives

ESTABLISHING DRLs in PEDIATRIC CT. Keith Strauss, MSc, FAAPM, FACR Cincinnati Children s Hospital University of Cincinnati College of Medicine

Application of CARE kv and SAFIRE in Contrast-Enhanced CT Examination on Thorax

Les Outils Cliniques de Demain en Scanner Cardiaque. Cardiaque Status en ECR 2018 From Diagnosis to Prognosis

Radiation Dose Reduction: Should You Use a Bismuth Breast Shield?

Acknowledgments. A Specific Diagnostic Task: Lung Nodule Detection. A Specific Diagnostic Task: Chest CT Protocols. Chest CT Protocols

Dual Energy CT of the Heart: Perfusion and Beyond

A study on CT pulmonary angiography at low kv and low-concentration contrast medium using iterative reconstruction.

Reducing Radiation Dose in Body CT: A Primer on Dose Metrics and Key CT Technical Parameters

(Non-EKG Gated) CTA Thoracic Aorta = CTA Chest

Emerging Applications in Musculoskeletal CT Imaging

Low-Dose CT: Clinical Studies & the Radiologist Perspective

Triple Rule-out using 320-row-detector volume MDCT: A comparison of the wide volume and helical modes

Radiology Rounds A Newsletter for Referring Physicians Massachusetts General Hospital Department of Radiology

CT Urography. Ureter. Stuart G. Silverman, M.D.

Scientific Exhibit. Authors: D. Takenaka, Y. Ohno, Y. Onishi, K. Matsumoto, T.

Ask EuroSafe Imaging. Tips & Tricks. CT Working Group

X-Ray & CT Physics / Clinical CT

Neuro CT What s a Good Head Exam?

Original Article Application of flash dual-source CT at low radiation dose and low contrast medium dose in triple-rule-out (tro) examination

Contrast-Enhanced Digital Mammography

Update on Acute Aortic Syndrome

Ask EuroSafe Imaging. Tips & Tricks. Paediatric Imaging Working Group. Shielding in pediatric CT

Vascular and Interventional Radiology Original Research

Dual-Energy CT Applications in the Abdomen

Spectral CT imaging as a new quantitative tool? Assessment of perfusion defects of pulmonary parenchyma in patients with lung cancer

Detecting Lung Nodules: Challenges and Solutions. Geoffrey D. Rubin, MD, MBA, FACR, FSCBTMR

CVIA. Dual-Layer Computed Tomography in Cardiovascular Imaging INTRODUCTION

Automatic Patient Centering for MDCT: Effect on Radiation Dose

Role of DE-CT in Oncology

Medical Physics and Informatics Original Research

CLINICAL PRESENTATION AND RADIOLOGY QUIZ QUESTION

Certainty. lives in layers. Philips IQon Spectral CT. Computed tomography

RadRx Your Prescription for Accurate Coding & Reimbursement Copyright All Rights Reserved.

Doses from pediatric CT examinations in Norway Are pediatric scan protocols developed and in daily use?

CT Perfusion. U. Joseph Schoepf, MD, FAHA, FSCBT MR, FSCCT Professor of Radiology, Medicine, and Pediatrics Director of Cardiovascular Imaging

SenoBright Contrast Enhanced Spectral Mammography Technology. Ann-Katherine Carton Sylvie Saab-Puong Matt Suminski

Contrast Enhanced Spectral Mammography (CESM) Updates

Variation in tube voltage dependence of X-ray CT image contrast attributed to the difference of object materials

CT Guided Procedures And Interesting Cases. Stephen Kim, MD Diagnostic and Interventional Radiology

Multimodality Imaging of the Thoracic Aorta

Metal Artifact Reduction by Dual Energy CT

What s New in Breast Imaging. Jennifer A. Harvey, M.D., FACR Professor of Radiology University of Virginia

Simon Nepveu 1, Irina Boldeanu 1, Yves Provost 1, Jean Chalaoui 1, Louis-Mathieu Stevens 2,3, Nicolas Noiseux 2,3, Carl Chartrand-Lefebvre 1,3

Evaluation and treatment of intracranial aneurysms using Dual Energy CT Angiography (DECTA) and rotational Digital Subtraction Angiography (DSA).

Contrast-Enhanced Spectral Mammography

Imaging Techniques in Improving Image Quality of CT Angiography: What are the Latest?

Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement

Ask EuroSafe Imaging. Tips & Tricks. CT Working Group. Optimization of scan length to reduce CT radiation dose

University of Groningen. Quantitative CT myocardial perfusion Pelgrim, Gert

New Technologies for Cardiac CT. Geoffrey D. Rubin, MD, MBA, FACR, FNASCI Duke University

Free Esophageal Perforation Following Hybrid Visceral Debranching and Distal Endograft Extension to Repair a Ruptured Thoracoabdominal Aortic

B-Flow, Power Doppler and Color Doppler Ultrasound in the Assessment of Carotid Stenosis: Comparison with 64-MD-CT Angiography

Multimodality Imaging in Aortic Diseases:

In routine clinical practice, the majority of single-source abdominal computed tomographic (CT) examinations are performed with a tube potential of 12

Pediatric chest HRCT using the idose 4 Hybrid Iterative Reconstruction Algorithm: Which idose level to choose?

Radiation Dose in Pediatric Imaging

Treatment options for endoleaks: stents, embolizations and conversions

Contrast enhanced spectral mammography: A literature review

MDCT PROTOCOLS FOR POLYTRAUMA PATIENTS

Case Report Three-Dimensional Dual-Energy Computed Tomography for Enhancing Stone/Stent Contrasting and Stone Visualization in Urolithiasis

Modifi ed CT perfusion contrast injection protocols for improved CBF quantifi cation with lower temporal sampling

CT Myocardial Perfusion: Is there Added Value to Coronary CT?

Utility of Dual-Energy CT to Evaluate Patients with Hip and Pelvis Pain in the ER Setting

Dual-Energy CT Applications in Head and Neck Imaging

BioMedical quantitative X-Ray Imaging. Emmanuel Brun Researcher Inserm Université Grenoble Alpes

ECG Gated CT Aorta in Transcatheter Aortic Valve Implantation

CT Pancreas 3 Phase CT Abdomen WO W - NC.A.V

Liver 4 Phase CT Abdomen WO W - NC.A.V.D

Acute Aortic Syndromes

Accuracy of iodine quantification using dual energy CT in latest generation dual source and dual layer CT

Combined Anatomical and Functional Imaging with Revolution * CT

Cardiac CT Techniques in Neonates (and infants)

Transcription:

Dual Energy CT Aortography: Can We Reduce Iodine Dose?? William P. Shuman MD, FACR FSCBTMR Department of Radiology University of Washington SCBTMR Annual Course Boston, October 10, 2012

Conflict of Interest Statement I administer an unrestricted grant from GE Healthcare which supports clinical investigation of advanced CT applications.

From: Silva AC et al, Radiographics 2011; 31: 1031

Ko JP et al, J Thoracic Imag 2012; 27:8

Ko JP et al, J Thoracic Imag 2012; 27:8

Should Every Body Case be DECT?? CT can now be performed routinely in DE Mode without additional dose or compromise in image quality Invest Radiol 2010; 45: 347 Dual Energy CT is equivalent and can be used for routine diagnostic purposes. AJNR 2011; 32:1994 Dual energy CT is now the routine for all my abdomen and pelvis studies. Alec Megibow, 2011

Abudirexiti A et al, Rad Phys; 2010; 3: 127

Can we use Dual Energy technique to markedly reduce the amount of iodine needed for a CT aortogram??

Because vasculopathy involves the whole body, many patients who need a CT aortogram have some compromise of renal function.

In CT, we harm more patients with iodine than we do with radiation.

What has published peerreviewed literature reported recently about iodine dose in CT aortography??

Single Energy CT Aortography Lower tube voltage reduces contrast material and radiation doses on 16- MDCT aortography Nakayama Y, et al AJR; 187: 2006

Single Energy CT Aortography Compared 100 kvp aortography using 100 ml of iodinated contrast (3 ml/sec) to 90 kvp using 40 ml. (2 ml/sec) Mean attenuation aorta: same Subjective scoring of renal and celiac artery enhancement: same

Optimizing DE-CT Aortogoraphy Single-Acquisition Dual-energy MDCT: Results: Vascular enhancement and post-processing for the thoracic aorta Godoy MCB, Naidich DP, et al JCAT; 34: 2010

Optimizing DE-CT Aortogoraphy 40 patients had DECT thoracic aortography (40/60% weighting between 80 and 140 kvp) 20 got 100-150 ml at 4.5 ml/sec 20 got 50-60 ml at 3.0 ml/sec

Optimizing DE-CT Aortogoraphy Results: At 80 kvp, image noise was higher but perceive image quality was same as 140 At 80 kvp, aortic enhancement and image quality with low iodine contrast dose technique comparable to 140 kvp with higher iodine dose

Single vs Dual Energy CT Aortography Initial Experience with single-source dual-energy CT abdominal aortography.: Image quality, enhancement, dose Pinho DF, Sahani DV, et al European Radiology, August, 2012

Single vs Dual Energy CT Aortography Virtual monochromatic spectral images from DECT depict how an object would look if the X-ray source produced only photons of a single energy (kev) Increased vessel iodine attenuation and CNR at lower kev, higher noise

Single vs Dual Energy CT Aortography 35 patients with repaired AAA had SECT of abdominal aortography followed within 6 months by DECT abdominal aortography Same volume of iodinated contrast and rate of injection given to both groups DECT-A post-processed to 50 and 70 kev

Single vs Dual Energy CT Aortography Results: Subjective: 70 kev best for image quality 50 kev best for renal artery branches Endoleaks best on 50 kev

Single vs Dual Energy CT Aortography Results: Quantitative: Mean aortic attenuation 50 kev = 800 HU 70 kev = 375 120 kvp = 297

Single vs Dual Energy CT Aortography Results: Quantitative: Aorta CNR 50 kev = 26 70 kev = 20 120 kvp = 11

Single vs Dual Energy CT Aortography Conclusion: Monochromatic (single kev) DECT images offer both higher aortic density and better image quality than SECT Better depiction of small branch renal arteries and small endoleaks.

Optimizing DE-CT Aortography Sweet Spot for endoleak detection: Optimizing CNR using low kev.dect Maturen KE, Quint LE, Platt JF et al JCAT; 36: 2012

Optimizing DE-CT Aortography The K edge of iodine is 33.2 kev. Lower kev DECT closer to this K edge will make iodine brighter during aortography but also increases image noise. Is there a CNR sweet spot?

Optimizing DE-CT Aortogoraphy 2 blinded readers subjectively assessed endoleak detection, type, and conspicuity in 39 patients DECT data set postprocessed to 55 kev vs. 75 kev

Optimizing DE-CT Aortogoraphy Results: Endoleak detection statistically higher at 55 than 75 kev (100% vs. 84%) Endoleak conspicuity higher at 55 kev Endoleak type characterization the same for both kev s

CNR vs. kev

Half Dose of Iodine and DE GSI HU 934 HU 650 HU 378 HU 271 Kev 42 Kev 51 Kev 66 Kev 77 W=1000, L=200

Single Energy, Full Dose Iodine HU = 320 GSI DECT kev 60, Half-Dose Iodine HU = 439

GSI DECT Aortogram, Half-Dose of Iodine kev 44 HU 960 kev 60 HU 439 kev 77 HU 252

GSI DE Aortography with Half-Dose of Iodine 40 kev 50 kev 70 kev 77 kev Aorta HU 882 579 284 233 HU<250 0% 7% 14% 61% Noise 40.4 24.4 14.3 15.1 CNR 21.2 22.1 17.4 12.7

GSI DE Aortography with Half-Dose of Iodine Conclusion: DECT aortography with 50% iodine dose reduction resulted in consistently dense enhancement of the abdominal aorta well above the threshold of 250 HU. The aorta CNR greatest at 50 kev.

DECT vs. SECT: Dose Comparison Dual energy abdominal CT Univ. of WA. experience: 2 years ago: DE 5 10% higher dose than our low-dose SE using NI = 36, ASIR 40% Today: NI and iterative recon. in DE have increased, lower radiation dose is achievable (through selectable rotation time) than our low-dose SE.

Summary Patient radiation dose in dual energy CT currently is slightly lower than low-dose single energy CT. A number of centers using DECT for all exams Advanced iterative reconstruction DECT enables substantial reduction of iodine dose for angiograms or for tissue enhancement (50% or greater reduction) Great for patients with renal compromise