There are different types of ICDs:

Similar documents
X-Plain Pacemaker Reference Summary

You and your pacemaker

Implantable Cardioverter Defibrillator

Cardiac Resynchronization Therapy (CRT) Heart Failure and Electrical Problems How CRT Helps Getting a Biventricular Pacemaker or ICD

Living With Your Implantable Cardioverter Defibrillator (ICD)

Your Subcutaneous Implantable Cardiac Defibrillator (ICD)

Caring for Your Pacemaker

After Your Implantable Cardiac Defibrillator (ICD) Generator Change

Caring for Your Implantable Cardiac Defibrillator (ICD)

After Your Pacemaker Generator Change

UNDERSTANDING PACEMAKERS

This leaflet is intended for patients with permanent pacemakers and their parents.

Pacemaker and ICD Interrogation

What to expect when having a pacemaker implantation

IMPLANTABLE CARDIOVERTER DEFIBRILLATORS (ICDs)

Implantable Cardioverter Defibrillators (ICDs) How ICDs Treat Fast Heart Rhythms Before, During, and After Implantation Living Well with an ICD

You have been referred to the Hamilton General Hospital to assess if having your mitral heart valve repaired with a mitral clip is right for you.

Implant Procedure Concepts

Pacemaker Therapy (PPM)

ICD Implantation Patient Information

Kadlec Regional Medical Center Cardiac Electrophysiology

Cardiac Catheterization

Cardiac Resynchronisation Therapy Patient Information

Parkinson s disease, Essential Tremor and primary dystonia

UNDERSTANDING ELECTROPHYSIOLOGY STUDIES

Care of Your Child with a Pacemaker

Implantation of a Cardiac Resynchronisation Therapy-Defibrillator (CRT-D)

Sacral Nerve Stimulation (SNS) System Implantation

Implantation of an Implantable Cardioverter Defibrillator (ICD)

Information for patients, parents and guardians. Your child s doctor has recommended that your child has a procedure called an ablation.

Procedures/Risks:central venous catheter

Yes, out of sight out of mind.

Neurostimulation. Spinal cord stimulators use electrodes placed in the space surrounding the spinal cord (epidural space).

Atrial Fibrillation. Damage to your heart caused by a heart attack or rheumatic heart disease

Newer pacemakers also can monitor your blood temperature, breathing, and other factors and adjust your heart rate to changes in your activity.

Catheter Ablation. Patient Education

Kadlec Regional Medical Center Cardiac Electrophysiology

Implantable Cardioverter Defibrillator (ICD) and Cardiac Resynchronisation Therapy Defibrillator (CRT-D)

Inserting an internal cardioverter defibrillator

Deep Brain Stimulation Surgery Interoperative Magnetic Resonance Imaging (imri)

Cardiac Resynchronisation Therapy Pacemaker (CRT-P)

Cardiac Resynchronisation Therapy Defibrillator (CRT-D)

Cardiac Catheterization Lab Procedures

About atrial fibrillation (AFib) Atrial Fibrillation (AFib) What is AFib? What s the danger? Who gets AFib?

Pacemaker and AV Node Ablation Patient Information

Different indications for pacemaker implantation are the following:

12.1 Apply Your Knowledge How long does an ambulatory monitor typically remain on a patient?

Your surgeon will order pre-operative testing before you have surgery.

The protection you need - without touching your heart

Implantable Loop Recorder

Deep Brain Stimulation (DBS)

Cardiac Catheterization Lab Procedures

Permanent Pacemaker Implantation / Box Change - A Guide to the Procedure

Implantable Cardioverter Defibrillator and Cardiac Resynchronization Therapy Implantation A guide for patients and families

Diagnostic tests for syncope

Living with Your Heart Failure Device (CRT)*

Electrocardiography for Healthcare Professionals

Apical Bullectomy Surgery

Stress testing may be done at a doctor's office or at a hospital. It will usually take between 1 and 3 hours.

THERAPY Baclofen Pump Program at Boston Children s Hospital

ICD Your quick guide. British Heart Foundation 2017, a registered charity in England & Wales (225971) and Scotland (SC039426).

AWAY Model # RTLAGF-900 REV

Arrhythmias. Pulmonary Artery

Diagnostic tests for syncope

Deep Brain Stimulation (DBS) For patients with tremor

Cardiac Resynchronization Therapy Defibrillator

HealthTalks. Deep Brain Stimulation for Parkinson s Disease Patients

Implantable Cardioverter Defibrillator Therapy

EMBLEM TM S-ICD System Patient Handbook

Transcutaneous Electrical Nerve Stimulator (TENS)

A Patient EDUCATION HANDBOOK ON ICD. A Patient Education Handbook on ICD 1

Transcatheter Aortic Valve Implant (TAVI) Sussex Cardiac Centre

Central Venous Catheter Care and Maintenance (includes catheter troubleshooting guide)

ATRIAL FIBRILLATION ANSWERS. A Patient Education Handbook on Electrophysiology

Mini Pulse Electronic Stimulator

EMBLEM TM S-ICD System Patient Handbook

Esophagectomy Surgery

Understanding Atrial Fibrillation A guide for patients

Coronary angioplasty and stents

FD.635.G561.PHC (R.Nov-13) Going Home After a Transcatheter Heart Valve Procedure

ICDs: Implantable. A Guide for Patients and Families 40 RUSKIN STREET, OTTAWA ON K1Y 4W7 T UOHI 75 (11/2014)

Vaxcel Implantable Ports Valved and Non-Valved. A Patient s Guide

Ileal Conduit Diversion Surgery

LVAD, RVAD, BiVAD, Total Artificial Heart

Open Abdominal Aortic Aneurysm Repair (AAA Repair)

Transcatheter Aortic Valve Implant (TAVI)

A SIMPLE SOLUTION FOR CARDIAC MONITORING

Atrial Septal Defect (ASD) Closure

Excisiona I Breast Biopsy

Which ECG is Right for You?

Patient Resources: Arrhythmias and Congenital Heart Disease

Patient guide: pfm Nit-Occlud PDA coil occlusion system. Catheter occlusion of. Patent Ductus Arteriosus. with the

Having a cardiac resynchronisation therapy CRT-P device implanted

Carry this card with you at all times. Show this card to any medical professional treating you. Patient Implant Card. Option ELITE Vena Cava Filter.

Implantable Loop Recorder

ICD SUPPORT GROUP IRELAND

Deep brain stimulation

Prostate Artery Embolization (PAE)

Ureteral Stenting and Nephrostomy

COALINGA STATE HOSPITAL. NURSING POLICY AND PROCEDURE MANUAL SECTION Emergency Procedures POLICY NUMBER: 716. Effective Date: March 3, 2007

Transcription:

Guidelines for Patients with Implantable Devices o Implantable Cardioverter Defibrillator (ICD) Your ICD is approximately the size of a pager and includes the following parts: The ICD: A battery powered device that is used to create an electrical shock to the heart when needed. The device is inserted under the skin (or muscle) below the collarbone. The Leads: Wires that are able to monitor the electrical impulses and send the electrical activity to the ICD as well as send electrical charges to the heart muscle when needed. The ICD leads are passed through the subclavian vein into the heart. There are different types of ICDs:

Single chamber ICD A lead is attached in the right ventricle. If needed, energy is delivered to the ventricle to help it contract normally Dual chamber ICD Leads are attached in the right atrium & the right ventricle. Energy is delivered first to the right atrium and then to the right ventricle, helping your heart to beat in a normal sequence Biventricular ICD Leads are attached in the right atrium, the right ventricle and the left ventricle. This technique helps the heart beat in a more balanced way and is specifically used for patients with heart failure.

During the Procedure: You will be given an antibiotic to prevent infection and a medication through your IV to relax you and make you drowsy, but it will not put you to sleep. The nurses and technicians will connect you to several monitors. The monitors allow the doctor and nurse to check your heart rhythm, blood pressure, and other measurements during the ICD implant. Your left or right side of your body, from your neck to your nipple area, will be shaved and cleansed with a special soap. Sterile drapes are used to cover you from your neck to your feet. After the procedure: Hospital stay: You will be admitted to the hospital for one to two days. The nurses will monitor your heart rate and rhythm. The length of your hospital stay depends on the type of ICD procedure you had. The morning after your implant, you will have an EKG, blood tests, and a chest x ray to ensure the leads and generator are in the proper position. Wound care: Keep your wound clean and dry. Look at your wound every day to make sure it is healing. Call your doctor if you notice: o Redness o Swelling o Drainage o Fever o Chills You will have a slight bulge under the skin where the generator is located. It will not be noticeable under clothes. ICD Identification: You will be given information about: o The type of ICD and leads you have o The date of implant o The doctor who implanted them. You will receive a card and a packet of information about your device when you are discharged from the hospital. It is important

that you carry this card with you at all times in case you need medical attention. Activity: You may move your arm normally and will be able to do most activities when you return home. o Avoid lifting objects that weigh more than 20 pounds or pushing or pulling heavy objects. o Your doctor or nurse will discuss specific activities with you before you leave the hospital. After your ICD is implanted you can expect that your device will require monitoring every three to six months. You will be provided with all necessary information regarding monitoring and servicing of your ICD. There are several items that may occur or you may experience with your ICD: Shocking If you experience a single shock with no other complications, no further treatment is necessary. If you receive frequent shocks, two or more shocks, or a cluster of shocks throughout several days or weeks please call our office to schedule an appointment and notify a medical technician. If you receive multiple shocks in one day or have dizziness, fainting, or other symptoms after the shock, please have someone take you to the Emergency Room immediately. Driving Your physician will provide you with any driving restrictions upon discharge. Medical Procedures Please notify all doctors, dentists, and other healthcare members that you have an ICD device so they may take all necessary precautions when determining your medical care. If your medical provider is unfamiliar with precautions for an ICD, please have them contact our office. Travel You may pass through security gates with your ICD device; however, if you do set off the alarm have the security personnel hand search you. Do not allow them to use the handheld wands as it may interfere with your device. It is recommended that you carry your ICD owner s card with you when you travel.

o Pacemaker Placement The following items are safe for an individual with an ICD device: Most house hold items which include hair dryers, heating pad, electric razors, remote controls, vacuum cleaners, TV s, CD players, radios, electric toothbrushes, computers, lawn mowers, and many other appliances and tools. Microwave ovens, blenders Cellular telephones The following items are not safe for an individual with an ICD device and should be avoided: Medical imaging with an MRI (magnetic resonance imaging) Magnetic devices should not be placed within six inches of your ICD (unless you are undergoing testing in our clinic) The distributor or coil of a gasoline engine while the engine is running SCUBA diving to depths in excess of one hundred feet Arc welding (unless certain precautions are taken as directed by your physician) A pacemaker is an electronic device designed to stimulate contraction of the heart muscle when it is no longer able to do so naturally. The device is placed just below the collarbone through a small surgical opening. There are three different types of Pacemakers: Single chamber pacemaker: Uses one lead in the upper or lower chamber of the heart Dual chamber pacemaker: Uses one lead in the upper chamber and one lead in the lower chamber of the heart.

Biventricular pacemaker: (pictured here) Uses three leads, placed in the: Right atrium, Right ventricle, Left ventricle (via the coronary sinus vein). During the Procedure: You will be given an antibiotic to prevent infection and a medication through your IV to relax you and make you drowsy, but it will not put you to sleep. The nurses and technicians will connect you to several monitors. The monitors allow the doctor and nurse to check your heart rhythm, blood pressure, and other measurements during the Pacemaker implant. Your left or right side of your body, from your neck to your nipple area, will be shaved and cleansed with a special soap. Sterile drapes are used to cover you from your neck to your feet.

After the procedure: Hospital stay: You will be admitted to the hospital for one to two days. The nurses will monitor your heart rate and rhythm. The length of your hospital stay depends on the type of Pacemaker procedure you had. The morning after your implant, you will have an EKG, blood tests and a chest x ray to ensure the leads and generator are in the proper position. Wound care: Keep your wound clean and dry. Look at your wound every day to make sure it is healing. Call your doctor if you notice: o Redness o Swelling o Drainage o Fever o Chills You will have a slight bulge under the skin where the generator is located. It will not be noticeable under clothes. Pacemaker Identification: You will be given information about: o The type of Pacemaker and leads you have o The date of implant o The doctor who implanted them. You will receive a card and a packet of information about your device when you are discharged from the hospital. It is important that you carry this card with you at all times in case you need medical attention. Activity: you may move your arm normally and will be able to do most activities when you return home. o Avoid lifting objects that weigh more than 20 pounds or pushing or pulling heavy objects. o Your doctor or nurse will discuss specific activities with you before you leave the hospital. There are several items that may occur or you may experience with your Pacemaker: Driving Your physician will provide you with any driving restrictions upon discharge.

Medical Procedures Please notify all doctors, dentists, and other healthcare members that you have a pacemaker so they may take all necessary precautions when determining your medical care. If your medical provider is unfamiliar with precautions for a pacemaker, please have them contact our office. Travel You may pass through security gates with your pacemaker; however, if you do set off the alarm have the security personnel hand search you. Do not allow them to use the handheld wands as it may interfere with your device. It is recommended that you carry your pacemaker owner s card with you when you travel. The following items are safe for an individual with a pacemaker: Most house hold items which include hair dryers, heating pad, electric razors, remote controls, vacuum cleaners, TV s, CD players, radios, electric toothbrushes, computers, lawn mowers, and many other appliances and tools. Microwave ovens, blenders Cellular telephones The following items are not safe for an individual with a pacemaker and should be avoided: Medical imaging with an MRI (magnetic resonance imaging) Magnetic devices should not be placed within six inches of your pacemaker (unless you are undergoing testing in our clinic) The distributor or coil of a gasoline engine while the engine is running SCUBA diving to depths in excess of one hundred feet Arc welding (unless certain precautions are taken as directed by your physician)

Pacemaker and an ICD: o Insertable Cardiac Monitor An insertable cardiac monitor is a small implantable device that continuously monitors heart rhythms and records them automatically or by using a hand held patient activator. The device is implanted just beneath the skin in the upper chest area during a simple procedure. When a fainting spell occurs, you or your family member should immediately place a small hand held activator over the cardiac monitor and press a button. This triggers the device to record the heart s signal before, during, and after the unexplained fainting spell. The insertable cardiac monitor is programmed to continuously monitor your heart s activity in the form of an electrocardiogram (EKG). It can also be programmed to record abnormal heart rhythms automatically. The insertable cardiac monitor is the gold standard for determining causes of infrequent, unexplained fainting. The insertable cardiac monitor is designed for long term use.

Because the heart monitor is placed under the skin, you do not have to use sticky recording pads on your skin or worry about connecting any wires. Your implantable loop recorder can be used up to 3 years, so it increases the chance of capturing your heart signal during infrequent fainting spells. The insertable cardiac monitor may help your doctor rule in or rule out abnormal heart rhythms as the cause of your unexplained fainting. Risks All surgical procedures carry some risk. Because the cardiac monitor is implanted just beneath the skin, there is a slight risk of infection, the device moving or coming through the skin, and/or sensitivity to the cardiac monitor material. The risks of something serious happening are rare. Remember to talk to your doctor about any concerns you have or anything you don t fully understand. During the Procedure: You will be asked to move onto a large x ray table, and you will see a lot of equipment around you. Nurses and technicians will prepare you for the procedure by placing EKG electrodes on your chest, cleansing your chest area with antiseptic solution and covering you with a sterile drape. You will be awake during the procedure and should experience very little discomfort. You will receive medication to help you relax. Your doctor will inject your upper chest with a local anesthetic that will numb the area. After this medication has taken effect, your doctor will make a small incision in your skin. The cardiac monitor will then be slipped under the skin. The edges of the wound will be either sewn with a couple of dissolvable stitches or glued together. The entire procedure will take only 15 20 minutes. A small dressing may be applied over the incision. After the Procedure: After the insertion, you will be returned to your room to recover, you will need to wait for an hour before discharge. Insertable Cardiac Monitor: