Reduced Ion Suppression and Improved LC/MS Sensitivity with Agilent Bond Elut Plexa

Similar documents
Author. Introduction. Small Molecule Pharmaceuticals & Generics

Modified QuEChERS for HILIC LC/MS/MS Analysis of Nicotine and Its Metabolites in Fish

Analysis of Cholesterol-Lowering Drugs (Statins) Using Dried Matrix Spot Technology

Application Note. Author. Abstract. Introduction. Food Safety

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ

LC/MS/MS of Trichothecenes and Zearalenone in Wheat Using Different Sample Prep Methods

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

Analyze Barbiturates in Urine with Agilent 6430 LC/MS/MS and Poroshell 120 EC-C18

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

LC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ

Direct Analysis of Folic Acid in Digestive Juices by LC/TOF-MS Application

Authors. Abstract. Forensic Toxicology. Irina Dioumaeva, John M. Hughes Agilent Technologies, Inc.

Author. Introduction. Abstract

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system

Application Note. Authors. Abstract. Food

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column

Analysis of Acrylamide in French Fries using Agilent Bond Elut QuEChERS AOAC kit and LC/MS/MS

Application Note. Abstract. Authors. Pharmaceutical

Detection, Confirmation, and Quantification of Chloramphenicol in Honey, Shrimp and Chicken Using the Agilent 6410 LC/MS Triple Quadrupole

Quantitative Analysis of Opiates in Urine Using RRHT LC/MS/MS. Application. Authors. Introduction. Abstract. Forensics

Agilent 6490 Triple Quadrupole LC/MS System with ifunnel Technology. Ultra sensitive quantitative performance

Determination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography

A FORENSIC TOXICOLOGY METHOD FOR THE DETERMINATION OF DESOMORPHINE, HEROIN, METHADONE, BUPRENORPHINE AND METABOLITES IN URINE USING LC/MS QQQ

Dr. Erin E. Chambers Waters Corporation. Presented by Dr. Diego Rodriguez Cabaleiro Waters Europe Waters Corporation 1

Quantitative Analysis of Underivatized Amino Acids in Plant Matrix by Hydrophilic Interaction Chromatography (HILIC) with LC/MS Detection

Cannabinoid Quantitation Using an Agilent 6430 LC/MS/MS

Using Software Tools to Improve the Detection of Impurities by LC/MS. Application Note. Christine Miller Agilent Technologies.

Removal of Triton X-100 from Plasma Samples Using Mixed-Mode Solid Phase Extraction (SPE)

DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

Quantitative Analysis of Amphetamine-Type Drugs by Extractive Benzoylation and LC/MS/MS. Application. Introduction. Authors. Abstract.

Identification of Steroids in Water by Ion Trap LC/MS/MS Application

Authors. Abstract. Introduction. Environmental

Sample Preparation Techniques for Biological Matrices: Finding the right balance to achieve optimal results

Fat-Soluble Vitamins Analysis on an Agilent ZORBAX Eclipse PAH Polymeric C18 Bonded Column

Determination of Amphetamine and Derivatives in Urine

Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Quantitation of Protein Phosphorylation Using Multiple Reaction Monitoring

Comprehensive Study of SLE as a Sample. Preparation Tool for Bioanalysis

Converting a CHP Method for Insulin to Agilent Poroshell 120 Columns

High Resolution Glycopeptide Mapping of EPO Using an Agilent AdvanceBio Peptide Mapping Column

Supporting Information

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

Quantitative Determination of Drugs of Abuse in Human Plasma and Serum by LC/MS/MS Using Agilent Captiva EMR Lipid Cleanup

Mycotoxin Analysis in Peanut Butter Using Captiva EMR Lipid Cleanup and LC/MS/MS

application Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Qualitative and quantitative determination of cannabinoid profiles and potency in CBD hemp oil using LC/UV and Mass Selective Detection

Determination of Amantadine Residues in Chicken by LCMS-8040

Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE. SLE+ Prior to LC/MS-MS Analysis

Determination of Sulfonamide Antibiotics in Bovine Liver Using Agilent Bond Elut QuEChERS EN Kits by LC/MS/MS

Analysis of mycotoxins in food matrices using the Agilent Ultivo Triple Quadrupole LC/MS

Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates

Extended Mass Range Triple Quadrupole for Routine Analysis of High Mass-to-charge Peptide Ions

Quantitative Determination of Drugs of Abuse in Human Whole Blood by LC/MS/MS Using Agilent Captiva EMR Lipid Cleanup

Vitamin D3 and related compounds by ESI and APCI

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit

Profiling of Endogenous Metabolites Using Time-of-Flight LC/MS with Ion Pair Reverse Phase Chromatography

Mycotoxin Analysis in Infant Formula Using Captiva EMR Lipid Cleanup and LC/MS/MS

Performance of an ultra low elution volume 96-well plate

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Efficient Quantitative Analysis of THC and Metabolites in Human Plasma Using Agilent Captiva EMR Lipid and LC-MS/MS

Simultaneous Quantitative Analysis of Total Catecholamines and Metanephrines in Urine Using CLEAN UP CCX2 and LC-MS/MS

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Determination of B-vitamins in Energy Drinks by CE/MS/MS

Impact of Chromatography on Lipid Profiling of Liver Tissue Extracts

2D-LC as an Automated Desalting Tool for MSD Analysis

Quantification of lovastatin in human plasma by LC/ESI/MS/MS using the Agilent 6410 Triple Quadrupole LC/MS system

Multiclass Mycotoxin Analysis in Cheese Using Agilent Captiva EMR Lipid Cleanup and LC/MS/MS

Selectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants

Determination of Benzodiazepines in Urine by CE-MS/MS

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

Extraction of 25-hydroxy Vitamin D from Serum Using ISOLUTE. PLD+ Prior to LC-MS/MS Analysis

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis

Determination of Isoflavones in Soybean by LC/MS/MS

Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC

Analysis of Vitamins Using an SFC/UHPLC Hybrid System with a Triple Quadrupole LC/MS for Quantification

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

Highly Repeatable Ultra Low Detection of Estradiol Using Triple Quadrupole GC/MS in NCI Mode

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

Analyze Biogenic Amines in Salmon and Shrimp by Capillary Electrophoresis-Tandem MS

Determination of 44 Pesticides in Foodstuffs by LC/MS/MS Application

using the Agilent 7696A Sample Prep

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Dienes Derivatization MaxSpec Kit

Determination of Aflatoxins in Food by LC/MS/MS. Application. Authors. Abstract. Experimental. Introduction. Food Safety

LC/MS Method for Comprehensive Analysis of Plasma Lipids

A Novel HILIC Column for High Speed N-linked Glycan Analysis

Identification of Imidacloprid Metabolites in Onions Using High Resolution Accurate Mass Spectrometry (LC/Q-TOF MS) and Accurate Mass Tools

Filtration Approaches to Sample Preparation and Cleanup. Golnar Javadi Application Engineer Sample Preparation Products

Determination of Multi-Residue Tetracyclines and their Metabolites in Milk by High Performance Liquid Chromatography - Tandem Mass Spectrometry

Separation of Polyphenols by Comprehensive 2D-LC and Molecular Formula Determination by Coupling to Accurate Mass Measurement

Fast quantitative Forensic Analysis of THC and its Metabolites in Biological Samples using Captiva EMR- Lipid and LC/MSMS

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

Extraction of Synthetic and Naturally Occurring Cannabinoids in Urine Using SPE and LC-MS/MS

Transcription:

Reduced Ion Suppression and Improved LC/MS Sensitivity with Agilent Bond Elut Plexa Application Note Small Molecule Pharmaceuticals & Generics Author Mike Chang Agilent Technologies, Inc. 5 Commercentre Drive Lake Forest, CA 96 USA Abstract In a comparison of SPE products, Agilent Bond Elut Plexa polymeric SPE reduces ion suppression for better sensitivity and low LOD and LOQ. Beta blockers are extracted with excellent correlation coefficients, recoveries, and % RSD. Introduction Ion suppression is often an issue in bioanalysis by LC/MS, resulting in poor recovery and inaccuracy, as well as increased instrument maintenance cost and time. Ion suppression cannot be avoided completely when biological samples are handled. However, it should be avoided wherever possible. Agilent Bond Elut Plexa has a hydroxylated surface whereas other competitor s products have amide residues on the surface of the sorbent. The presence of amide residue can cause increased interaction between the SPE sorbent and the endogenous materials in biological samples, which can be directly responsible for ion suppression during bioanalysis. Due to hydroxylation of the sorbent s surface, Bond Elut Plexa reduces the interaction between the sorbent and endogenous materials in biological matrices to improve sensitivity. In this example, we present clear evidence of ion-suppression reduction and improved sensitivity with Bond Elut Plexa mono-dispersed polymeric SPE. The sample was human plasma spiked with beta blockers.

Materials and Methods SPE reagents and solutions % aqueous ammonia Add µl diluted NH OH to ml H O MeOH Reagent grade or better 5% MeOH Add 5 µl MeOH to ml H O 5:5 MeOH:ACN Add ml MeOH to ml ACN SPE method All samples were processed by the same SPE method. SPE products Agilent Bond Elut Plexa 96-well plate ( mg) (p/n A969) Competitor W 96-well plate ( mg) Competitor P 96-well plate ( mg) Sample µl human plasma Pretreatment Dilute with µl % aqueous ammonia Condition. 5 µl MeOH. 5 µl H O Load µl diluted sample from pretreatment (actual plasma µl) Wash 5 µl 5% MeOH Elute Twice with 5 µl 5:5 ACN:MeOH Experiment set up For ion-suppression comparison, a drug compound mixture (5 ng/ml) was continuously infused by syringe pump at µl/min. The blank plasma sample was injected. Blank plasma samples were prepared by Agilent Bond Elut Plexa and two other competitor s products based on the SPE methods specified above. MS transition 8 & 8 m/z was selected for lipid content monitoring during the analysis. Figure shows the experimental set up. LC Conditions Column Agilent Poroshell EC-C8,. mm 5. mm,.7 µm (p/n 699775-9) Instrument Agilent 6 Infinity LC/MS Mobile phase A.% formic acid in H O Mobile phase B.% formic acid in MeOH Flow rate. ml/min Injection volume µl Gradient Time (min) %B. 9. 6.5 Temperature sample (5 C), column (ambient) Ion-source ESI+ with JetStream Gas temperature 5 C Gas flow L/min Nebulizer 5 psi Sheath gas temperature C Sheath gas flow L/min Capillary V Samples Beta blocker pka log P MS/MS transition Collision energy Fragmentor Acebutolol 9..7 7. & 6. 8 Nadolol 9.67.8. & 5. 9 Atenolol 9.6.6 67. & 9. 9 Propranolol 9..8 6. & 6. 6 9 Pindolol 9.5.75 9. & 6. 9 Metoprolol (ISTD) 9.7.9 68. & 6. 6 9 Results and Discussion Figure. Schematic of experiment setup for ion-suppression comparison. Good separation and retention between all analytes were obtained, as shown in Figure. Reduced ion-suppression delivered higher sensitivity resulted, as demonstrated in Figure. The figure shows an overlay of extracted MS chromatograms for nadolol from all three SPE products when blank plasma sample was injected and continuous infusion of drug mixture were executed simultaneously. The signal from Bond Elut Plexa was higher than from the other products during most of the analysis. Figure shows an overlay of extracted MS/MS chromatogram 8 & 8 m/z for all three SPE products. The data show clearly that Bond Elut Plexa has reduced ion-suppression when compared to the others. For calibration and recovery, plasma was spiked with drug compounds of corresponding concentrations. For ion-suppression comparison, blank plasma samples were processed with SPE.

x.5..5..5. x..5..5. x.6....8.6.. x..8.6.. Acebutolol Nadolol Atenolol Propranolol x 5 Figure. MS chromatogram of spiked plasma sample processed by Agilent Bond Elut Plexa (5 ng/ml of each analyte). Pindolol...7.9...5.7.9...5.7.9...5.7.9...5.7.9 5. 5. 5.5 5.7 5.9 6. 6. Counts vs. aquisition time (min)...9.8.7.6.5.....9.8.7.6.... Agilent Bond Elut Plexa Competitor W Competitor P.5.5.5.5 5 5.5 6 Counts vs. acquisition time (min) Bond Elut Plexa showed higher sensitivity for analytes during the most of the gradient region due to less ion suppression. Figure. Overlay of the nadolol signal from simultaneous injection of blank plasma sample and continuous infusion of drug mixture, showing the superiority of Agilent Bond Elut Plexa.

8 7.5 7 6.5 6 5.5 5.5.5.5.5 Agilent Bond Elut Plexa Competitor W Competitor P Mobile phase injection Figure..5.5.5.5 5 5.5 6 Counts vs. acquisition time (min) Lipid content monitoring of blank plasma sample injection by 8 & 8 m/z transition, with reduced ion suppression using Agilent Bond Elut Plexa. Bond Elut Plexa achieved excellent limit of detection (LOD ~.5 ng/ml) and limit of quantitation (LOQ ~ ). A recovery experiment was performed at three different concentration levels (low, mid, and high, n = 6) and the data are summarized in Table, with excellent recovery and % RSD. Calibration curves were created with nine concentration levels (. ng/ml) and all compounds showed good linearity with correlation coefficients R.995 (Figure 5). Table. Results of a Recovery Experiment using AgilentBond Elut Plexa pka log P LOD (ng/ml) LOQ 5 ng/ml 5 ng/ml ng/ml Correlation (ng/ml) Recovery (%) RSD (%) Recovery (%) RSD (%) Recovery (%) RSD (%) coefficient, R Acebutolol 9..7..5 79. 8.9.7 97...996 Nadolol 9.67.8..5 98.5.8 9.7. 8..8.997 Atenolol 9.6.6.5 9.7.9..5 9..5. Propranolol 9..8.5 6..7 9.9 7. 6.9 9.7.995 Pindolol 9.5.75..5.6. 6.. 5..8.998

.5.5.5 y =.787 * x R =.996955 Acebutolol 5 6 7 8 9 8 7 6 5 y =.777 * x R =.99969 Propranolol 5 6 7 8 9.5 y =.898 * x R =.99685.5 y =.89 * x R =.99856.5.5 Nadolol.5.5 Pindolol 5 6 7 8 9 5 6 7 8 9.. 9 8.7.6.... _. Figure 5. y = 66 * x R =.9995597 Atenolol 5 6 7 8 9 Calibration curves of five beta blockers at nine concentration levels (.,.5,.,,, 5,, 5, and ng/ml). 5

Conclusion Agilent Bond Elut Plexa reduced ion suppression when compared to other SPE products, resulting in better sensitivity. The improved sensitivity delivered low LOD (..5 ng/ml) and LOQ (.5 ng/ml). In addition, excellent correlation coefficients (R.995) and good recovery data were obtained with very good % RSD. For More Information For more information on our products and services, visit our Web site at www.agilent.com/chem. www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc., Printed in the USA December, 599-888EN