Long-Standing Persistent Atrial Fibrillation: Can We Distinguish Ectopic Activity From Reentry by Epicardial Mapping?

Similar documents
PDF hosted at the Radboud Repository of the Radboud University Nijmegen

Electropathological Substrate of Long-Standing Persistent Atrial Fibrillation in Patients With Structural Heart Disease Longitudinal Dissociation

CARDIOLOGY GRAND ROUNDS

Electrophysiology 101: What Do Surgeons Need to Know. Richard B Schuessler PhD

Cardiac Arrhythmia Mapping!

QUest for the Arrhythmogenic Substrate of Atrial fibrillation in Patients Undergoing Cardiac Surgery (QUASAR Study): Rationale and Design

Reentry in a Pulmonary Vein as a Possible Mechanism of Focal Atrial Fibrillation

Electrophysiologic Properties of Pulmonary Veins Assessed Using a Multielectrode Basket Catheter

Seungyup Lee, PhD; Jayakumar Sahadevan, MD; Celeen M. Khrestian, BS; Alan Markowitz, MD; Albert L. Waldo, MD, PhD (Hon)

FREQUENCY COHERENCE MAPPING OF CANINE ATRIAL FIBRILLATION: IMPLICATION FOR ANTI-ARRHYTHMIC DRUG-INDUCED TERMINATION

The Regional Distribution and Correlation. Complex Fractionated Atrial Electrograms and Dominant Frequency in. during Atrial Fibrillation

Catheter Ablation for Persistent Atrial Fibrillation

Influences of Anisotropic Tissue Structure on Reentrant Circuits in the Epicardial Border Zone of Subacute Canine Infarcts

High-Densiy Mapping of Electrically Induced Atrial Fibrillation in Humans

Contemporary Strategies for Catheter Ablation of Atrial Fibrillation

The Future. Sanjiv M. Narayan, MD, PHD, FHRS, FRCP Professor of Medicine, University of California San Diego San Diego Veterans Affairs Medical Center

EHRA/EUROPACE 2011 Madrid, Spain June

Deposited on: 29 October 2009

Catheter ablation of atrial fibrillation: Indications and tools for improvement of the success rate of the method. Konstantinos P.

How to Ablate Atrial Tachycardia Mechanisms and Approach. DrJo Jo Hai

Στροφείς (rotors) και πραγματικότητα. Χάρης Κοσσυβάκης Επιμελητής A Καρδιολογικό Τμήμα Γ.Ν.Α. «Γ. ΓΕΝΝΗΜΑΤΑΣ»

Circulation: Arrhythmia and Electrophysiology CHALLENGE OF THE WEEK

Fibrillatory Conduction in the Atrial Free Walls of Goats in Persistent. and Permanent Atrial Fibrillation

A Dynamic model of Pulmonary Vein Electrophysiology. Harry Green 2 nd year Ph.D. student University of Exeter

ANALYSIS AND VISUALIZATION OF ATRIAL FIBRILLATION ELECTROGRAMS USING CROSS-CORRELATION

arxiv: v1 [q-bio.to] 29 Oct 2018

Characteristics of Rapid Rhythms Recorded Within Pulmonary Veins During Atrial Fibrillation

Peri-Mitral Atrial Flutter with Partial Conduction Block between Left Atrium and Coronary Sinus

The impact of hypertension on the electromechanical properties and outcome of catheter ablation in atrial fibrillation patients

It has been demonstrated in animal models that chronic

Journal of the American College of Cardiology Vol. 37, No. 5, by the American College of Cardiology ISSN /01/$20.

V. TACHYCARDIAS Rapid rhythm abnormalities

The EP Perspective: Should We Do Hybrid Ablation, and Who Should We Do It On?

Case Report. Sumito Narita MD 1;3, Takeshi Tsuchiya MD, PhD 1, Hiroya Ushinohama MD, PhD 2, Shin-ichi Ando MD, PhD 3

Atrial Fibrillation: Classification and Electrophysiology. Saverio Iacopino, MD, FACC, FESC

Mapping techniques in AFib. Helmut Pürerfellner, MD Public Hospital Elisabethinen Academic Teaching Hospital Linz, Austria

Polymorphic ventricular tachycardia (VT) has been reported

Wavelength and vulnerability to atrial fibrillation: Insights from a computer model of human atria

Ablation Lesion Assessment

Mechanism of Immediate Recurrences of Atrial Fibrillation After Restoration of Sinus Rhythm

A New Approach for Catheter Ablation of Atrial Fibrillation: Mapping of the Electrophysiologic Substrate

Mechanisms of atrial fibrillation terminations in humans: insights from non-invasive cardiac mapping

PVI and What Else for Persistent AF Lessons Learned from STAR AF 2 CCCEP 2015 October 31, New York

Anisotropic Conduction in the Triangle of Koch of Mammalian Hearts: Electrophysiologic and Anatomic Correlations

Case Report Electroanatomical Mapping and Ablation of Upper Loop Reentry Atrial Flutter

Rotor Mapping A FIRM Foundation Exists

Changes in the Atrial Substrate Alters the Spatiotemporal Organization and Characteristics of Atrial Fibrillation

Mapping Cardiac Pacemaker Circuits: Methodological puzzles of SAN optical mapping

CARDIOINSIGHT TM NONINVASIVE 3D MAPPING SYSTEM CLINICAL EVIDENCE SUMMARY

How to Distinguish Focal Atrial Tachycardia from Small Circuits and Reentry

Debate-STAR AF 2 study. PVI is not enough

Creating Order out of Chaos: New Research into Treatment of Atrial Fibrillation

More Musing About the Interrelationships of Atrial Fibrillation and Atrial. Flutter and Their Clinical Implications

Conventional Mapping. Introduction

Research Article Characterization of Electrograms from Multipolar Diagnostic Catheters during Atrial Fibrillation

Electrophysiological and Electroanatomic Characterization of the Atria in Sinus Node Disease. Evidence of Diffuse Atrial Remodeling

Diagnostic Electrophysiology & Ablation

Prolongation of conduction time during premature stimulation in the human atrium is primarily caused by local stimulus response latency

A MODEL OF GAP JUNCTION CONDUCTANCE AND VENTRICULAR TACHYARRHYTHMIA

New Parameter to Predict Recurrence of Paroxysmal Atrial Fibrillation after Pulmonary Vein Isolation by the P-Wave Signal-Averaged Electrocardiogram

A RAPID CYCLE LENGTH VARIABILITY DETECTION TECHNIQUE OF ATRIAL ELECTROGRAMS IN ATRIAL FIBRILLATION

Paroxysmal Supraventricular Tachycardia PSVT.

Ablation of Ventricular Tachycardia in Non-Ischemic Cardiomyopathy

Computational Mapping Identifies Localized Mechanisms for Ablation of Atrial Fibrillation

2017 HRS/EHRA/ECAS/APHRS/SOLAECE Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation

Abstract Clinical and paraclinical studies on myocardial and endocardial diseases in dog

Impact of the Arrhythmogenic Potential of Long Lines of Conduction Slowing at the Pulmonary Vein Area

Πρώτης γραμμή θεραπεία η κατάλυση κοιλιακής ταχυκαρδίας στην ισχαιμική μυοκαρδιοπάθεια

Catheter ablation of AF Where do we stand, where do we go?

UltraRapid Communication

Phase 2 Early Afterdepolarization as a Trigger of Polymorphic Ventricular Tachycardia in Acquired Long-QT Syndrome

Hunter, Ross J. For additional information about this publication click this link.

State of the Art. Atrial Fibrillation: A Question of Dominance?

Ablation of persistent AF Is it different than paroxysmal?

Atrial fibrillation (AF) is the most common arrhythmia in

A request for a log book extension must be put in writing and sent to BHRS, Unit 6B, Essex House, Cromwell Business Park, Chipping Norton,

Journal of the American College of Cardiology Vol. 42, No. 2, by the American College of Cardiology Foundation ISSN /03/$30.

Tachycardia Around a Fixed Obstacle in Anisotropic Myocardium

AF Today: W. For the majority of patients with atrial. are the Options? Chris Case

480 April 2004 PACE, Vol. 27

Cardiac Arrhythmias. Cathy Percival, RN, FALU, FLMI VP, Medical Director AIG Life and Retirement Company

Chapter 16: Arrhythmias and Conduction Disturbances

1995 Our First AF Ablation. Atrial Tachycardias During and After Atrial Fibrillation Ablation. Left Atrial Flutter. 13 Hours Later 9/25/2009

Map-Guided Ablation of Non-ischemic VT. Takashi Nitta Cardiovascular Surgery, Nippon Medical School Tokyo, JAPAN

High density substrate mapping In AF

EKG Abnormalities. Adapted from:

Novel Approaches to VT Management Glenn M Polin MD

NATIONAL INSTITUTE FOR CLINICAL EXCELLENCE

Nonuniform Epicardial Activation and Repolarization Properties of in Vivo Canine Pulmonary Conus

Principles and Applications of Electrical Circuits and Signal Theories in EP

BASIC CONCEPT OF ECG

Catheter Ablation of Atrial Fibrillation

Is cardioversion old hat? What is new in interventional treatment of AF symptoms?

Accepted Manuscript. What Can We Learn From a Novel Global Positioning System in Persistent Atrial Fibrillation? Kenton Zehr, M.D.

The Wavelength of the Cardiac Impulse and Reentrant Arrhythmias in Isolated Rabbit Atrium

AF ABLATION Concepts and Techniques

ECG Interpretation Made Easy


Structural remodeling and conduction velocity dynamics in the human left atrium: Relationship with reentrant mechanisms sustaining atrial fibrillation

Transcription:

Long-Standing Persistent Atrial Fibrillation: Can We Distinguish Ectopic Activity From Reentry by Epicardial Mapping? Running title: de Bakker et al.; Can epicardial mapping reveal the AF mechanism? Jacques M.T. de Bakker, PhD 1,2 ; Pascal F.H.M. van Dessel, MD, PhD 1 1 Dept of Clinical and Experimental Cardiology, Heart Center, Amsterdam, the Netherlands; 2 The Interuniversity Cardiology Institute of the Netherlands, Utrecht, the Netherlands Address dres s for Correspondence: ence Jacques M.T. de Bakker, PhD Academic Medical Center Department of Experimental Cardiology, Heart Center Meibergdreef 9 1105AZ Amsterdam, the Netherlands. Tel: +31 205663271 Fax: +31 206975458 E-mail: j.m.debakker@amc.uva.nl Journal Subject Terms: Arrhythmias; Atrial Fibrillation; Electrophysiology Key words: Editorial; arrhythmia (mechanisms); atrial fibrillation arrhythmia; atrial fibrillation heart failure; electrophysiology mapping 1

Both abnormal impulse initiation and reentry have been proposed as mechanism for the initiation and maintenance of atrial fibrillation (AF). Ectopic activity of the pulmonary veins often is the electrical trigger for AF in patients with paroxysmal AF. A high impulse frequency of the ectopic focus may give rise to irregular, fibrillatory conduction, which leads to the freakish electrical pattern of AF. It is, however, often unclear whether the ectopic activity is based on abnormal impulse formation or abnormal conduction (reentry). Experimental and clinical data provide evidence for both mechanisms. 1 Other data show that multiple wavelet reentry may be present in the early phase of atrial remodelling as well. 2 Remodelling of the atrium may be progressive due to an underlying cardiac disease and/or the arrhythmia itself (AF begets AF). 3 Remodelling involves changes of structural, electrical cal and neural parameters. This will change the mechanism of AF and finally result in persistent AF, in which the substrate becomes more complex and AF is more difficult to treat. Knowledge about the mechanism of the arrhythmia is important for treatment tmen ent strategies, tegi es, but there is still discussion i about the mechanism of AF. Although h evidence ence has been provided for both reentry ry and abnormal impulse initiation, itia iati tion one should realize that the mechanism may change if remodelling progresses. In addition, the mechanism of AF will depend on the underlying cardiac disease. Heart failure, hypertension, valvular heart disease, Wolff Parkinson-White syndrome and hyperthyroidism are all triggers for AF and may give rise to different mechanisms of the arrhythmia. In this issue of Circulation, the Waldo group carried out high density epicardial mapping of the atria in patients with persistent AF. 4 Patients had multiple comorbidities and virtually all had valvular heart disease, hypertension and heart failure, which means that the group of patients is rather uniform. The investigators observed that epicardial wave fronts originated from foci or 2

breakthrough sites and that reentry in this group of patients did not occur. Both, mapping of the epicardial electrical activity and waveform analysis have been used to support these conclusions. Recordings were carried out carefully and results are interesting and important in delineating treatment strategies, but the question arises how solid the mapping data are to distinguish reentrant from focal mechanisms. Mapping of atrial electrical activity Mapping of the electrical activity during an arrhythmia is often the method of choice to delineate its mechanism. However, this method is not without pitfalls. To proof reentry, the presence of an activation map that shows continuity of activation in a (reentrant) circuit is not sufficient. Continuity may be apparent, for instance in case focal activation exits unidirectionally ly and activation arrives via the presumed reentry path at the exit site just before a next ectopic activation tion is issued. sued Similarly, a site from which electrical activation spreads centrifugally does not necessarily mean that myocardial al cells at that site generate activation atio ion by abnormal impulse initiation. itia iati If a reentrant rant circuit is small compared to the inter-electrode rode distance of the recording grid, the activation tion pattern tern may also be centrifugally. Another interfering factor is the fact that recordings are often made in two dimensions (2D), whereas the heart, including the atria, has 3 dimensions (3D). The role of the third dimension of the atria has been investigated in detail by the group of Allessie. 5 The reason for a 2D choice in the clinical setting is clear because 3D mapping requires needle electrodes to be impaled in the myocardium, an undesirable procedure in patients. Thus, epicardial activation maps should be considered with care and spatial resolution of electrode terminals must be sufficient. In the study of Waldo et al. spatial resolution of the mapping electrodes was 5.2 7.0 mm, which means that reentry circuits with a smaller diameter might have been missed. 3

Experimental studies have shown that the diameter of reentrant circuits can be much smaller, at least in the experimental setting. 6 The distance between isochronal lines on the epicardium could also be helpful to discriminate an epicardial origin from epicardial breakthrough. If the epicardial activation pattern is generated by an epicardial focus, the isochronal lines are closer together then in the case there is epicardial breakthrough. To use this tool, the magnitude of the conduction velocity at the epicardium should be known. However, as shown in figure 5 of the study of Waldo et al., the epicardial activation pattern can be rather complex. 4 Multiple areas of conduction block and breakthrough or focal sites are present. The involved anatomical structure of the atrium will certainly contribute to this complexity, which is further increased by the remodelling process. s. All these factors make the interpretation of epicardial maps challenging. Electrogram ram morphology to distinguish focal activity from reentry Electrogram morphology might also be helpful to distinguish inguis ish focal activity from reentry, ry, but also here different pitfalls are present. ent. The morphology of the unipolar electrogram provides information ion about the behaviour of the wave front at the recording rdin site. If the activation atio ion front passes the electrode terminal, the unipolar electrogram is biphasic, consisting of a positive deflection followed by a negative one. The positive deflection is caused by the approaching wave front, whereas the negative deflection is generated by the receding front. If activation is blocked, the electrogram is only positive, whereas the signal is negative only at a site where activation arises. 7 Although these rules are in general correct, there are exceptions. The initially negative deflection in the unipolar electrogram is frequently used to trace an origin of activation, i.e. ectopic activity. However, the same shape of the unipolar electrogram may arise at a tissue discontinuity, for instance a site where a small bundle inserts in a broad one. A wave front 4

traveling via the small bundle toward the wide one will generate a tiny R-wave at the interface between the bundles. In contrast, the activation front in the wide bundle that recedes from the interface will generate a large negative deflection (Q) because the tissue mass and therefore the extracellular current that generates the electrogram, is large. Anisotropy of cardiac tissue can also disturb the simple concept of signal morphology. Spach et al. have shown that by stimulating an epicardial sheet of cardiac tissue, recordings made at sites where activation moves perpendicular to the fiber direction may reveal initially negative deflections. 8 These negative deflections are, however, remote and caused by the strong activation fronts that run in the fiber direction, away from the recording site. Similar effects may arise at sites of epicardial breakthrough in the atrium. The general idea is that focal epicardial al activity ity generates a Q-wave in the unipolar electrogram at the epicardial origin and that in case of an epicardial al breakthrough an R-wave (due to the approaching proaching wave front from the endocardium) precedes the Q-wave. However, er, at sites where the wall thickness is small, the approaching achi wave front from the endocardium d may be tiny and hardly generates an R-wave at the epicardial site that faces the endocardial dial origin. It is true that in the majority of the cases an R-wave is present, ent, but its amplitude is small and can easily be missed. 9 In addition, a breakthrough site is not very informative regarding the mechanism of the arrhythmia, because it can be caused by epi/endo reentry as well or by a focus that is located at the endocardium or intramurally. Which mechanisms does high resolution mapping of persistent AF in man reveal? Studies with high resolution mapping of persistent AF have been performed in patients during cardiac surgery by several groups. 9,10,11 De Groot et al. observed that fibrillation waves were frequently of focal origin, but these waves were not repetitive and were found over the entire epicardial surface. Unipolar electrograms at the earliest activated epicardial sites exhibited R- 5

waves, suggesting that they were caused by epicardial breakthrough. Similar observations with epicardial exit sites, but without sustained activity were made by Lee et al. 10 According to Allessie, these high resolution mapping studies point to epicardial-endocardial dissociation as mechanism for persistent AF. 12 These data differ from the observations made by Waldo et al., but as outlined before it is often difficult to distinguish a real focus from breakthrough on the base of electrogram morphology or an epicardial activation map. Narayan et al. claimed that human AF might also be due to rotors, driving sustained AF. 13,14 Mapping of the electrical activity was, however, carried out with basket catheters, which have a much lower spatial resolution than the electrodes used during intraoperative mapping. Next to the reduced spatial resolution, basket recordings suffer from contact problems, which results in artefacts and further reduces the number of electrodes that can be used for analysis. In addition, special analysing techniques were used to produce videos of activation from which the mechanism was inferred ed. The quality of the electrograms and the analysis technique used question whether er rotors are indeed present in man. 15 There is still uncertainty ty about the mechanism of persistent sten ent AF in man. Jalife et al. observed spiral wave reentry in animal models. 16 Transient rotational activity around a core of high frequency activity suggesting the presence of a rotor has been described in man, but data about sustained rotors are missing. 13 The high resolution mapping of Waldo et al. indicates that macro reentry at the epicardium does not occur. Their data do, however, not exclude the possibility that micro-reentry, transmural reentry and/or endo-epicardial dissociation are involved. Conflict of Interest Disclosures: None. 6

References: 1. Nitta T, Sakamoto S, Miyagi Y, Fujii M, Ishii Y, Ochi M. Reentrant and focal activations during atrial fibrillation in patients with atrial septal defect. Ann Thorac Surg. 2013;96:1266-1272. 2. Konings KT, Kirchhof CJ, Smeets JR, Wellens HJ, Penn OC, Allessie MA. High-density mapping of electrically induced atrial fibrillation in humans. Circulation. 1994;89:1665-1680. 3. Wijffels MC, Kirchhof CJ, Dorland R, Allessie MA. Atrial fibrillation begets atrial fibrillation. A study in awake chronically instrumented goats. Circulation. 1995;92:1954-1968. 4. Waldo AL, Sahadevan J, Khrestian CM, Cakulev I, markovwitz A, Lee S. Simultaneous biatrial high density (510-512 electrodes) epicardial mapping of persistent and long-standing persistent atrial fibrillation in patients: New insights into the mechanism of its maintenance. Circulation. 2015;132:XX-XXX. 5. Eckstein J, Zeemering S, Linz D, Maesen B, Verheule S, van Hunnik A, Crijns H, Allessie MA, Schotten U. Transmural conduction is the predominant mechanism of breakthrough roug during atrial fibrillation: evidence from simultaneous endo-epicardial high-density activation tion mapping. ping Circ Arrhythm Electrophysiol. 2013;6:334-341. 6. Spach MS, Dolber PC, Heidlage JF. Influence of the passive anisotropic properties on directional differences in propagation following modification of the sodium conductance in human atrial muscle. A model of reentry en based on anisotropic opic discontinuous inuous propagation. paga o Circ Res. 1988;62:811-832. 7. de Bakker JM, Wittkampf tkam FH. The pathophysiologic hysio basis of fractionated t and complex electrograms ectr rams and the impact of recording techniques on their detection and interpretation. reta tati tion Circ Arrhythm Electrophysiol. 2010;3:204-213. 8. Spach MS, Miller WT 3rd, Miller-Jones E, Warren RB, Barr RC. Extracellular potentials related to intracellular action potentials during impulse conduction in anisotropic canine cardiac muscle. Circ Res. 1979;45:188-204. 9. de Groot NMS, Houben RPM, Smeets JL, Boersma E, Schotten U, SchalijMJ, Crijns H, Allessie MA. Electropathological substrate of longstanding persistent atrial fibrillation in patients with structural heart disease: epicardial breakthrough. Circulation. 2010;122:1674-1682. 10. Lee G, Kumar S, Teh A, Madry A, Larobina M, Goldblatt J, Brown R, Atkinson V, Moten S, Morton JB, Sanders P, Kistler PM, Kalman J. Epicardial wave mapping in human long-lasting persistent atrial fibrillation: transient rotational circuits, complex wave fronts and disorganized activity. Eur Heart J. 2014;35:86-97. 7

11. Wu TJ, Doshi RN, Huang HLA, Blanche C, Kass RM, Trento A, ChengW, KaragueuzianHS, Peter CT, Chen PS. Simultaneous biatrial computerized mapping during permanent atrial fibrillation in patients with organic heart disease. J Cardiovasc Electrophysiol. 2002;13:571-577. 12. Eckstein J, Maesen B, Linz D, Zeemering S, van Hunnik A, Verheule S, Allessie M, Schotten U. Time course and mechanisms of endo-epicardial electrical dissociation during atrial fibrillation in the goat. Cardiovasc Res. 2011;89:816-824. 13. Narayan SM, Krummen DE, Rappel WJ. Clinical mapping approach to diagnose electrical rotors and focal impulse sources for human atrial fibrillation. J Cardiovasc Electrophysiol. 2012;23:447-454. 14. Narayan SM, Shivkumar K, Krummen DE, Miller JM, RappelWJ. Panoramic electrophysiological mapping but not electrogram morphology identifies stable sources for human atrial fibrillation. Stable atrial fibrillation rotors and focal sources relate poorly to fractionated electrograms. Circ Arrhythm Electrophysiol. 2013;6:58-67. 15. Allessie M, de Groot N. CrossTalk opposing view: Rotors have not been demonstrated to be the drivers of atrial fibrillation. J Physiol. 2014;592:3167-3170. 16. Jalife J, Berenfeld O, Mansour M. Mother rotors and fibrillatory conduction: a mechanism of atrial fibrillation. Cardiovasc Res. 2002;54:204-216. 8