III Instructions CPI - Condylar Position Indicator. These instructions apply to the following items: h2500 Includes: 9611 D 9615 D

Similar documents
Articulator Instructions

Analog Selector Instructions

Face-Bow Instructions

3000 Series Articulator System

Kois Dento-Facial Analyzer System Instructions

The Hanau Modular Articulator System 194 Fixed 11 cm width, adjustable Radial-Shift Guidances. Illustrated Instruction Manual

The Hanau Modular Articulator System 190 Fixed 11 cm width, adjustable Bennett Angle and/or Adjustable Protrusion. Illustrated Instruction Manual

Horizontal jaw relations: The relationship of mandible to maxilla in a

AD2 MEASURES CONDYLE DISPLACEMENT (MCD) MANUAL

Unique Dental Supply. Catalog We Bring World Quality Products to Enhance your Business QUALITY PRODUCTS SINCE 1974

Cybex Leg Extension. Legs

A-dec 372L or 572L Dental Light on an A-dec Performer Dental Chair INSTALLATION GUIDE

Lab Procedure Prior to Try-in

Prosthodontics. Dental articulator. 1-Allow most of the prosthetic work to be done in the absence of the patient.

MM01-Facebow And Bite Registration Procedure Checklist

Multipower. User Guide E S S E N T I A L S T R E N G T H

Symposium on Occlusal Articulation. Mandibular Movement Recordings and Articulator Adjustments Simplified. Harry C. Lundeen, D.D.S.

Jaw relation (Maxillomandibular relationship): any one of the infinite

Horizontal Jaw Relation

KneeAlign System Surgical Technique Guide

Articulators. 5- Wax up and refining the occlusion for dental restorations.

SaeboMAS (Patent Pending)

CHAIR ASSEMBLY & CARE GUIDE

Low Row. User manual E S S E N T I A L S T R E N G T H

SelectTech 3.1 Bench Assembly / Owner s Manual

Bowflex Home Gym- PR1000

Bite-Tab Compound Disks 180/box Накусочные таблетки для фиксации прикусной вилки лицевой дуги. Features & Benefits. Bite-Tray регистраты 50/Bag

INSTRUCTION MANUAL LEG PRESS (NEW MODEL) OPTION OF K2 GYM

PRIMARY POROUS PATELLA WITH TRABECULAR METAL. Surgical Technique

Intramedullary Tibial Preparation

SAFETY LABELS CAUTION: PINCH POINT. Make sure locking pin is fully engaged before beginning forward and side lift exercises.

Introduction to the Panadent System

TOTAL KNEE ARTHROPLASTY SYSTEM

Owner s Manual & Exercise Guide

Bledsoe Extender Brace Application Instructions CP Rev D 03/07

weight.detach/bench ITEM NO: 76310

Introduction to the Taylor Spatial Frame Hardware. Trademark of Smith & Nephew. Certain marks Reg. US Pat. & TM Off.

Calibration and Checking

A novel cementless option. Zimmer NexGen Trabecular Metal Primary Patella Surgical Technique

SelectTech 4.1 Bench Assembly / Owner s Manual

Extramedullary Tibial Preparation

Trabecular Metal Primary Patella

PH-04A: Clinical Photography Production Checklist With A Small Camera

Ultimate Personal Training Biceps Exercise Guide

PAL Pelvic Alignment Level

SelectTech 4.1 Bench. Assembly Manual

Owner s Manual WARNING

QUICK REFERENCE GUIDE. The PreFix Fixator (92000 Series) ALWAYS INNOVATING

Impression Manual.

1. Abs Triangle of Control Muscle: Upper abdominals Resistance: Body weight Body Connection: Legs

Ellipse Rehab Phase 2 Strengthening

IMPORTANT SAFETY NOTICE:

X-plode MULTI-PURPOSE WEIGHT LIFTING BENCH

User s Guide 2004 Horizon Fitness Products Designed & Engineered in the U.S.A. Made in China

USER MANUAL Rev. 1.15

insafe System - Directions for Use

Orthopedic Bone Nail System - Distal Femoral Nail Surgical Technique Manual

Important Safety Instructions 1-2. Maintenance 3. Features 4. Assembly Parts List 5. Assembly Instructions 6-9. Console Operation 10

We have simplified the. for you! Just a few steps to the articulator system of your choice! choose the perfect articulator for you!

LEG PRESS ADAPTER KIT FOR GS1/GS2 GYM SYSTEM

Technique Guide. Midface Distractor System. For the temporary stabilization and gradual lengthening of the cranial or midfacial bones.

CROSS TRAINING MAGNETIC TREADMILL

Hanau Series H2 Articulator

TWIST STEPPER NO. 045

The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are

Checklist with summary points

8500 Series Articulator and QuickMount Face-Bow Instruction Manual

Zimmer NexGen Trabecular Metal Tibial Tray

COMPACT BENCH MWB Model MWB Retain This Manual for Reference OWNER'S MANUAL

Workshop Outline. Pre-operative planning

Technique Guide. Rapid IMF Device. Temporary mandibular fixation device.

AIR WALKER TRAINER USER MANUAL SF-E902

S E L E C T I O N. Adjustable Bench. User manual. All equipment T H E S T R E N G T H E V O L U T I O N

S U R G I C A L T E C H N I Q U E David A. McQueen, MD Return to Menu

Advanced Catheterisation Trainer User Guide

Breezhaler. Open to see clear capsule. How do I use my Breezhaler? Care of my Breezhaler

Orthotics Measurement Board for Tibial Torsion and Toe-Out

limbsandthings.com Advanced Catheterisation Trainer User Guide For more skills training products visit Limbs & Things Ltd.

Jaw movements engraved in solid plastic for articulator controls. Part I. Recording apparatus

The Enbrel SureClick autoinjector is a single-dose prefilled autoinjector. It contains one 50 mg dose of Enbrel.

Surveying. 3rd year / College of Dentistry/University of Baghdad ( ) Page 1

Intelligent Orthopaedics

TORUS HOME GYM EXERCISE GUIDE

2011 EliteSoccerPower.com

Sunny Magnetic Exercise SF-B910

Sony Ericsson W810I Vibration Cell

Contents. Safety and Precautions Practical Exercise Tips...8. Information for Healthcare Professionals...9. Installation Instructions:

Shoulder Arthroscopic Capsular Release Rehabilitation

3. PATIENT POSITIONING & FRACTURE REDUCTION 3 8. DISTAL GUIDED LOCKING FOR PROXIMAL NAIL PROXIMAL LOCKING FOR LONG NAIL 13

Strength & Conditioning for Cyclists


PCR Starter Kit. For 3 32-well blocks, 0.2 ml USER GUIDE USER GUIDE. Part. No Revison B

Conventus CAGE PH Surgical Techniques

III IIII. United States Patent (19) Albergo. Attorney, Agent, or Firm-Michaelson & Wallace

OPERATIVE TECHNIQUE SKS Total Knee Replacement

Zimmer Trabecular Metal Ankle Interpositional Spacer and Trabecular Metal Ankle Fusion Spacer

WEIGHT BENCH MWB Model MWB Retain This Manual for Reference OWNER'S MANUAL

SP-300 OWNER S MANUAL

Transcription:

M Panadent Corporation 580 S. Rancho Avenue Colton, California 92324, USA Tel: (909) 783-1841 USA & Canada (800) 368-9777 CPI - III Instructions Condylar Position Indicator These instructions apply to the following items: h2500 Includes: 9611 D 9615 D Complete CPI-III Nomenclature a ) 2501 CP b ) 9611 CP c ) 9615 CP d ) 2550 CP e ) 9354 CP CPI - III Maxillary and mandibular frames with support column Graph papers (20 sets) Data record sheets (50) Elastic support bands (12) Optical resolver and illuminator (Optional) 1

2 Maxillary and mandibular CPI frames joined together with inter-frame support column 3 Graph papers (pad of 20 sets) 4 Patient record sheets (pad of 50) 5 Elastic support bands 2

OPTIONAL: Optical resolver and illuminator with lens protector (batteries not included) 6 Remove rubber safety band around vertical graph support of CPI. Lock both vertical graph supports (with associated thumbscrew) firmly in contact with maxillary frame. (Do not over-tighten thumbscrews.) 7 Raise and lock anterior support pin about five (5) centimeters above plastic incisal table. 8 Loosen mounting plate thumbscrew and remove maxillary frame from inter-frame support column. Do not force or bind precision locating dowels when removing frame from support column. 9 3

10 Pull soft plastic protector cap from marking pin for horizontal graph. 11 Place maxillary frame on right side graph support for placing left vertical graph paper. Note anterior end of frame resting on "foot" of transverse support post (arrow). 12 With small-ended dental instrument (e.g. Tanner carver), lift one end of vertical graph paper. Grasp free end of graph paper with thumb and index finger. Press tip of dental instrument against rectangular cut-outs on graph paper while slowly peeling adhesive coated paper from backing sheet. (Two small rectangular cut-outs should remain attached to backing sheet after graph paper has been removed.) 13 Hold both ends of graph paper with thumbs and index fingers. Brace index fingers against anterior and posterior ends of graph support and stretch paper tightly. Align both vertical and horizontal cross lines of paper with cross lines on graph support. After final alignment is complete, apply light finger pressure to adhere paper firmly to graph support. 4

Turn maxillary frame on left side and repeat procedure 12-13 for right side graph paper. 14 Attach interchangeable articulator mounted maxillary cast to upper frame of CPI with mounting plate thumbscrew (or magnetic mounting plate). 15 Loosen mounting plate thumbscrew and remove inter-frame support column from mandibular frame of CPI. Avoid binding column on precision dowel holes during removal. 16 Set mandibular frame upright with legs resting on a flat stable working surface in preparation for placing horizontal graph paper. Remove protective caps from both axis pointer elements. 17 5

18 Lift one end of horizontal graph paper and peel it slowly from backing sheet. 19 Stretch horizontal graph paper laterally with thumbs and index fingers. Align heavy center line of paper with center line of graph support. (Anterior-posterior position is not critical.) 20 Attach interchangeable articulator mounted mandibular cast to lower frame of CPI with mounting plate thumbscrew (or magnetic mounting plate). 21 Place CR or M.I.P. interocclusal record (depending on the procedure) on mandibular cast. 6

Fit maxillary cast into interocclusal record. Press firmly downward on maxillary frame with one hand to keep casts completely seated in interocclusal record (arrows). 22 With other hand, loosen anterior support pin thumbscrew and allow support pin to drop down freely until end of pin makes solid contact with Incisal Table (horizontal arrow). Lock support pin firmly in down position with thumbscrew. 23 Note: If support pin falls too near distal end of support table, support pin can be placed in the anterior pin hole on maxillary frame. Place two elastic support bands over maxillary mounting plate thumbscrew. Have one elastic support band hanging to right side and one to left side of maxillary cast. 24 While pressing firmly downward on maxillary frame with one hand (top vertical arrow), use index finger and thumb of other hand to spread and stretch one elastic support band down and over both retainer pins protruding horizontally from side of mandibular frame below mandibular cast (bottom arrows). 25 7

26 Continue downward hand pressure on maxillary frame after first elastic support band has been placed. Place opposite side elastic support band over retaining pins with thumb and index finger in same manner as other side. 27 Remove hands. Supported assembly holds position. 28 Loosen locking thumbscrew for vertical graph support in preparation for marking vertical graph. 29 Place single sided marking ribbon over graph paper (dye toward paper) with fingers of one hand. Grasp distal end of graph support with thumb and index finger of other hand for marking graph paper. 8

Pull laterally on distal end of graph support (arrow) to bring graph paper in contact with axis pointer. 30 Warning: Do not use excess force when marking graph. Excess pressure will cause sharp point of axis pointer to penetrate paper, scratching anodized surface of graph support and also dulling tips of pointer. Do not pull or push on anterior end of graph support to mark graph paper as support may bind. 31 After marking graph paper, lock graph support in contact with side of maxillary frame with thumbscrew. 32 Repeat procedures 28-31 to mark axis on opposite side vertical graph paper in same fashion as other side. 33 9

34 Lock graph support in contact with maxillary frame. 35 Place marking ribbon (dye toward graph paper) with index finger and thumb of one hand. Mark horizontal graph by lifting up on distal end of graph support with index finger of other hand (vertical arrow). 36 In preparation for removing casts from CPI, release and remove the two lateral elastic support bands from their associated retainer pins below mandibular cast. 37 Hold mandibular frame firmly against working surface with one hand. Lift maxillary frame assembly vertically from mandibular frame assembly with other hand 10

Remove interocclusal record from mandibular cast. 38 Hold horizontal graph support down with index finger of one hand. Peel graph paper slowly from graph support with thumb and finger of other hand. 39 Place horizontal graph paper to patient data record sheet via self-adhesive backing on graph paper. 40 Remove vertical graph papers from maxillary frame by peeling paper slowly away from graph supports. 41 11

42 Shorten graph papers by cutting ends at vertical tick lines on either side of millimeter grid. 43 Place vertical graph papers to patient's data record sheet via self-adhesive backing on graph papers. 44 OPTIONAL: Use optical resolver (10x) and illuminator to read graph markings accurately with 0.1mm reticle scale in resolver. 45 Press protector cap completely over horizontal graph marking pin. 12

Press protective cap completely over both axis pointer elements. 46 For storage of CPI, reattach maxillary and mandibular frames to inter frame support column. Lock both vertical graph supports in contact with maxillary frame. 47 For technical support call (909) 783-1841 Degree of Accuracy: Graph Paper +/-.004in /.1mm Optical Resolver 1mm lines +/-.004in /.1mm.1mm lines +/-.0008in /.02mm iu D 9611: If used more than one time, it will no longer adhere to surface. D 9615: If used more than one time, paper may be torn and therefore unusable. 13