Certificate of Accreditation to ISO/IEC 17025:2005

Similar documents
National Voluntary Laboratory Accreditation Program

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Page 1 of 7 Pages Weight ID Number 12345A Certificate Number SECTION 1: NAME AND ADDRESS OF CUSTOMER Date of Calibration 15-MAY-2018

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Calibration Standards

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

LAB5 EDITION 2 NOVEMBER 2012

Withdrawn at December 31, Guideline DKD-R 6-2. Calibration of Measuring Devices for Vacuum DEUTSCHER KALIBRIERDIENST. Part 1.

Temperature. Pressure. Humidity. Consultation & Training Services. Electrical. Certus Metrology

Sterilization of health care products Radiation. Part 3: Guidance on dosimetric aspects of development, validation and routine control

PROFICIENCY TESTING AND OTHER COMPARISON PROGRAMME REQUIREMENTS FOR CALIBRATION LABORATORIES

Form for Regular Reporting of Regional Instrument Centres

Multi Analyte Custom Grade Solution

CERTIFICATE OF ANALYSIS. tel: fax:

The design and development of a force comparator standard machine to provide national traceability in force measurement to industry.

PCSIR Laboratories Complex, Peshawar-Pakistan.

DOSIMETRY PRODUCTS & SERVICES 2018 PRICE LIST

CERTIFICATE OF ANALYSIS

Proficiency Testings (PTs) and Interlaboratory Comparisons (ILCs) for the Department of Calibration Laboratories

Guide to Fulfillment of Measurement Uncertainty

Back to Basics - Uncertainty. Presented by: Neill Stanford, CHP Stanford Dosimetry LLC Presented at the 2007 Dosimetry and Records Symposium

Developments in IAF/PAC/ILAC/APLAC/ISO. Anil Jauhri CEO, NABCB

ISO and the Delivery of Competent NDT Services

Policy for Participation in Proficiency Testing Activities

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF ACOUSTICS, ULTRASOUND AND VIBRATION METROLOGY

Proficiency Testing Policy

ISO INTERNATIONAL STANDARD

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems

Comparability and quality of experimental data under different quality systems. S. Caroli Istituto Superiore di Sanità Rome

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

Reference Material Institute for Clinical Chemistry Standards (ReCCS)

Agenda. 15 Dec

UKAS Guidance on the Application of ISO/IEC Dealing with Expressions of Opinions and Interpretations

Use of Target Values in EQA

Test report KIBING SPECIAL GLASS ZHANGZHOU CO., LTD CHENG AN ROAD, KANGMEI TOWNSHIP, DONGSHAN COUNTY ZHANGZHOU,FUJIAN, CHINA

Nuclear energy, nuclear technologies, and radiological protection Vocabulary. Part 4: Dosimetry for radiation processing

Sterilization of health care products - Radiation - Part 3: Guidance on dosimetric aspects

Non-destructive testing Penetrant testing. Part 2: Testing of penetrant materials

American Association for Laboratory Accreditation

Evaluation of measurement uncertainty of urine output using two kinds of urine bags

Raad voor Accreditatie (Dutch Accreditation Council RvA) Migration from BS OHSAS 18001:2007 to ISO 45001:2018

LAS-Q008. Proficiency Testing Requirements for Testing and Calibration Laboratories

DECEMBER 21, 2007 TEST REPORT # REVISION 1.1 MECHANICAL SHOCK/RANDOM VIBRATION TESTING PART NUMBERS ERM8-025-L-D-EM2 ERF

ISO Dentistry Digitizing devices for CAD/CAM systems for indirect dental restorations Test methods for assessing accuracy

Drug Treatment Centre Board

UK National Aerospace NDT Board

EVALUATION QUESTIONNAIRE

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Airmid Health Group Limited t/a Airmid Health Laboratory

Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties

World-Wide Radiation Metrology: The BIPM, the CIPM MRA, and ICRU

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Sandy Perle. Radiation Litigation: an Expert Witness Perspective

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

Certificate of Analysis JCCRM 811-1

Accreditation of Dosimetry Services

IES LM79-08 Sphere and Goniometer Test Report

CERTIFICATE OF ACCREDITATION

Ricardo Bettencourt da Silva

GUIDELINES OF IMPORTS FOR THE TRADE EMIRATES CONFORMITY ASSESSMENT SCHEME (ECAS) HALAL CERTIFICATION - MIDDLE EAST

a practical guide ISO 13485:2016 Medical devices Advice from ISO/TC 210

This document is a preview generated by EVS

This document is a preview generated by EVS

2018 Council on Ionizing Radiation Measurements and Standards. Low Energy ( kev) Electron Beam Calibration. Gary Pageau

This document is a preview generated by EVS

OHSAS Project Group. Implementation Guidance for migrating from OHSAS 18001:2007 to ISO 45001:2018 CONTENTS 1.0 INTRODUCTION

APMP-APLAC joint PT (APLAC T109) Measurement of Cadmium in Milk Powder

CERTIFICATE OF ACCREDITATION

This document is a preview generated by EVS

Sterile hypodermic needles for single use Requirements and test methods

Asbestos Containing Materials Assessment 294 Earle Drive Greenville, South Carolina

Sandy Perle. Radiation Litigation: an Expert Witness Perspective

UNITED ARAB EMIRATES

IMPLEMENTATION COURSE (MODULE 1) (ISO 45001:2016 AVAILABLE ON REQUEST) COURSE DURATION: 3 DAYS FOR OHSAS 18001:2007 OR ISO 45001:2016

Certified Reference Materials - A Path to Traceable Chemical Measurements

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

TG Approved By: SANAS Page 1 of 6

Lecture 2. In The Name of Allah. Instrumentation. Dr. Ali Karimpour Associate Professor Ferdowsi University of Mashhad

Role of Countries (1)

A Guide for Choosing the Right Calibration for Torque Transducers

Calibration Solutions. be certain.

Analysis of e-liquid and e-cigarettes Vapoting test results

EVALUATING THE UNCERTAINTY OF MEASUREMENT ON BLOOD'S GLUCOSE LEVEL

NANDTB-F012 Rev 0 Audit Checklist

Medical Bureau of Road Safety

Free Fatty Acids Test Standard

IAEA EXPERIENCE IN ISO ACCREDITATION OF WHOLE BODY COUNTER AS PART OF THE RADIATION MONITORING AND PROTECTION

Measures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer

IAS Presentation at Kuwait Labs nd Kuwait Conference for Laboratory Quality and Accreditation Empowering Laboratory Personnel

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

NMISA A discussion on Force ILC's and methods to improve results. 13 October 2015 Speaker: S.T.S. Dlamini Author: C.H. Gouws

IES LM Test Report

Length: 507 mm Width: 581 mm Height: 854 mm. Materials: Frame: Ø16 mm metal tubes Shell: 6 mm plastic

Medical Bureau of Road Safety

Water Microbiology Proficiency Test Scheme. Overview & Description

Fundamentals of Pulse Oximetry

The techniques of continually improving the quality system for ISO accredited laboratories

Transcription:

United States Department of Commerce National Institute of Standards and Technology Certificate of Accreditation to ISO/IEC 17025:2005 NVLAP LAB CODE: 200454-0 National Standards of Puerto Rico Rio Piedras, PR is accredited by the National Voluntary for specific services, listed on the Scope of Accreditation, for: CALIBRATION LABORATORIES This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communique dated January 2009). NVLAP-01C (REV. 2009-01-28)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 National Standards of Puerto Rico 281 Jesus T. Pinero Avenue P.O. Box 11936 Rio Piedras, PR 00922-1936 Mr. Fernando Hernandez Phone: 787-751-6777 Fax: 787-751-5920 E-mail: fernando@nsprlab.net URL: http://www.nsprlab.net Parameter(s) of Accreditation Mechanical Thermodynamic This laboratory is compliant to ANSI/NCSL Z540-1-1994; Part 1. (NVLAP Code: 20/A01) MECHANICAL MASS DETERMINATION (20/M08) Mass Metric 20 kg 5.7 mg Echelon I 10 kg 1.5 mg 5 kg 0.75 mg 3 kg 0.75 mg 2 kg 0.24 mg 1 kg 50 μg 500 g 28 μg 300 g 28 μg 200 g 19 μg 100 g 15 μg 50 g 9.6 μg 30 g 9.6 μg 20 g 6.0 μg 10 g 4.3 μg 5 g 1.7 μg 3 g 1.7 μg 2 g 1.2 μg 1 g 1.0 μg 500 mg 0.58 μg 300 mg 0.58 μg 200 mg 0.44 μg 100 mg 0.43 μg 50 mg 0.51 μg Page 1 of 7 NVLAP-02S (REV. 2011-08-16)

30 mg 0.51 μg 20 mg 0.42 μg 10 mg 0.47 μg 5 mg 0.41 μg 3 mg 0.41 μg 2 mg 0.20 μg 1 mg 0.26 μg 20 kg 5.5 mg Echelon II 10 kg 1.9 mg 5 kg 0.80 mg 3 kg 0.80 mg 2 kg 0.37 mg 1 kg 50 μg 500 g 30 μg 300 g 30 μg 200 g 22 μg 100 g 21 μg 50 g 10 μg 30 g 10 μg 20 g 7.1 μg 10 g 6.1 μg 5 g 2.7 μg 3 g 2.7 μg 2 g 2.6 μg 1 g 2.6 μg 500 mg 3.2 μg 300 mg 3.2 μg 200 mg 1.8 μg 100 mg 2.7 μg 50 mg 2.0 μg 30 mg 2.0 μg 20 mg 2.1 μg 10 mg 1.9 μg 5 mg 1.7 μg 3 mg 1.7 μg Page 2 of 7 NVLAP-02S (REV. 2011-08-16)

2 mg 1.5 μg 1 mg 1.5 μg 20 kg 5.7 mg 10 kg 1.7 mg 5 kg 0.79 mg 3 kg 0.79 mg 2 kg 0.27 mg 1 kg 51 μg 500 g 35 μg 300 g 35 μg 200 g 32 μg 100 g 22 μg 10 g 4.7 μg 5 g 3.1 μg 3 g 3.1 μg 2 g 1.3 μg 1 g 1.9 μg 50 kg 14 mg 30 kg 14 mg 20 kg 14 mg 10 kg 1.8 mg 5 kg 1.4 mg 3 kg 1.2 mg 2 kg 1.2 mg 1 kg 1.2 mg 500 g 0.12 mg 300 g 0.12 mg 200 g 0.12 mg 100 g 0.12 mg 50 g 0.12 mg 30 g 10 μg 20 g 7.3 μg 10 g 6.0 μg 5 g 5.3 μg Echelon III (Single Substitution) Echelon III (Modified Substitution) Page 3 of 7 NVLAP-02S (REV. 2011-08-16)

3 g 18 μg 2 g 18 μg 1 g 18 μg 500 mg 18 μg 300 mg 6.1 μg 200 mg 6.0 μg 100 mg 6.0 μg 50 mg 6.0 μg 30 mg 6.0 μg 20 mg 6.0 μg 10 mg 6.0 μg 5 mg 6.0 μg 3 mg 6.0 μg 2 mg 6.0 μg 1 mg 6.0 μg THERMODYNAMIC HUMIDITY (20/T02) Humidity Measuring Instruments @ 25 C 10 % RH 0.91 % RH 50 % RH 0.72 % RH 75 % RH 1.1 % RH 85 % RH 1.1 % RH By Comparison to Humidity Standard with Chamber LABORATORY THERMOMETERS, DIGITAL AND ANALOG (20/T03) Liquid in Glass Thermometers -80 C to -40 C 0.053 C -40 C to -20 C 0.052 C -20 C to 0 C 0.053 C 0 C 0.052 C Ice Point 0 C to 50 C 0.052 C 50 C to 150 C 0.053 C 150 C to 200 C 0.052 C 200 C to 250 C 0.053 C Digital Thermometers -196 C to -80 C 0.043 C -80 C to -40 C 0.043 C Page 4 of 7 NVLAP-02S (REV. 2011-08-16)

-40 C to -20 C 0.043 C -20 C to 0 C 0.056 C 0 C 0.040 C Ice Point 0 C to 50 C 0.049 C 50 C to 100 C 0.075 C 100 C to 200 C 0.045 C 200 C to 250 C 0.042 C 250 C to 420 C 0.048 C Temperature Measuring Instruments in Air 5 C 0.19 C 25 C 0.20 C 40 C 0.26 C 45 C 0.26 C Comparison to Temperature Standard with Chamber RESISTANCE THERMOMETRY (20/T07) Platinum Resistance Thermometers by Comparison -196 C to -80 C 9.6 mk -80 C to -40 C 9.0 mk -40 C to -20 C 7.5 mk -20 C to 0 C 10 mk 0.01 C 1.9 mk 0 C to 50 C 8.2 mk 50 C to 100 C 9.1 mk 100 C to 200 C 8.3 mk 200 C to 250 C 11 mk 250 C to 420 C 26 mk ITS 90 Fixed Point Zn FP 419.527 C 9.1 mk Sn FP 231.928 C 7.9 mk In FP 156.5985 C 3.8 mk H2O TP 0.01 C 1.9 mk Hg TP -38.8344 C 2.6 mk LN 2-189.3442 C 9.6 mk Comparison to SPRT Page 5 of 7 NVLAP-02S (REV. 2011-08-16)

THERMOCOUPLES (20/T11) Thermocouples -196 C to -80 C 0.030 C -80 C to -40 C 0.022 C -40 C to -20 C 0.021 C -20 C to 0 C 0.042 C 0 C 0.015 C Ice Point 0 C to 50 C 0.13 C 50 C to 100 C 0.14 C 100 C to 200 C 0.12 C 200 C to 250 C 0.12 C 250 C to 420 C 0.13 C END Page 6 of 7 NVLAP-02S (REV. 2011-08-16)

Notes Note 1: A Calibration and Measurement Capability (CMC) is a description of the best result of a calibration or measurement (result with the smallest uncertainty of measurement) that is available to the laboratory s customers under normal conditions, when performing more or less routine calibrations of nearly ideal measurement standards or instruments. The CMC is described in the laboratory s scope of accreditation by: the measurement parameter/device being calibrated, the measurement range, the uncertainty associated with that range (see note 3), and remarks on additional parameters, if applicable. Note 2: Calibration and Measurement Capabilities are traceable to the national measurement standards of the U.S. or to the national measurement standards of other countries and are thus traceable to the internationally accepted representation of the appropriate SI (Système International) unit. Note 3: The uncertainty associated with a measurement in a CMC is an expanded uncertainty using a coverage factor, k = 2, with a level of confidence of approximately 95 %. Units for the measurand and its uncertainty are to match. Exceptions to this occur when marketplace practice employs mixed units, such as when the artifact to be measured is labeled in non-si units and the uncertainty is given in SI units (Example: 5 lb weight with uncertainty given in mg). Note 3a: The uncertainty of a specific calibration by the laboratory may be greater than the uncertainty in the CMC due to the condition and behavior of the customer's device and specific circumstances of the calibration. The uncertainties quoted do not include possible effects on the calibrated device of transportation, long term stability, or intended use. Note 3b: As the CMC represents the best measurement results achievable under normal conditions, the accredited calibration laboratory shall not report smaller uncertainty of measurement than that given in a CMC for calibrations or measurements covered by that CMC. Note 3c: As described in Note 1, CMCs cover calibrations and measurements that are available to the laboratory s customers under normal conditions. However, the laboratory may have the capability to offer special tests, employing special conditions, which yield calibration or measurement results with lower uncertainties. Such special tests are not covered by the CMCs and are outside the laboratory s scope of accreditation. In this case, NVLAP requirements for the labeling, on calibration reports, of results outside the laboratory s scope of accreditation apply. These requirements are set out in Annex A.1.h. of NIST Handbook 150, Procedures and General Requirements. Note 4: Uncertainties associated with field service calibration may be greater as they incorporate on-site environmental contributions, transportation effects, or other factors that affect the measurements. (This note applies only if marked in the body of the scope.) Note 5: Values listed with percent (%) are percent of reading or generated value unless otherwise noted. Note 6: NVLAP accreditation is the formal recognition of specific calibration capabilities. Neither NVLAP nor NIST guarantee the accuracy of individual calibrations made by accredited laboratories. Note 7: See NIST Handbook 150 for further explanation of these notes. Note 8: Mass values at other than fixed points indicated are available at higher uncertainties. Note 9: Temperature uncertainties are based on typical values of characteristics such as hysteresis, homogeneity, DUT resolution, repeatability, and drift. These factors will be included at time of test and uncertainty will be higher than values listed. Page 7 of 7 NVLAP-02S (REV. 2011-08-16)