Visualisation of the Cochlea Implant/Tissue Interface

Similar documents
Cochlear Implant The only hope for severely Deaf

Cochlear Implant Failure: Imaging Evaluation of the Electrode Course

Manchester Adult Cochlear Implant Programme

Wheaton Journal of Neuroscience Senior Seminar Research

Cochlear Implant Impedance Fluctuation in Ménière s Disease: A Case Study

Research Article MRI-Based Estimation of Scalar Cochlear-Implant Electrode Position

Clinical Study Imaging of Electrode Position after Cochlear Implantation with Flat Panel CT

A surgical approach for a cochlear implant: An anatomical study

ALESSANDRA RUSSO MD GRUPPO OTOLOGICO

Investigating the Effect of Cochlear Size in Insertion of Electrode Depth in Patients with Cochlear Implantation Evaluated by CT- Scan

Series Preface. Preface. Acknowledgments. Abbreviations

CONFLICTS OF INTEREST

SOLUTIONS Homework #3. Introduction to Engineering in Medicine and Biology ECEN 1001 Due Tues. 9/30/03

Hearing. istockphoto/thinkstock

For Professionals. Electrode Arrays. Designed for Atraumatic Implantation Providing Superior Hearing Performance

For Professionals. SYNCHRONY System. In Sync with Natural Hearing

Your ear consists of three parts that play a vital role in hearing-the external ear, middle ear, and inner ear.

MICROTIA. The condition is a complex mix of cosmetic, functional, and often psychological difficulties. Microtia: Not only the ear.

Original Policy Date

BIOMATERIALS AND COCHLEAR IMPLANTS

ORIGINAL ARTICLE. new implantation method, the combined electric-acoustic stimulation

Receptors / physiology

An optical coherence tomography study for imaging the round window niche and the promontorium tympani

WHAT IS MANAGEMENT IN PDT?

Electrode Impedance among Children Using the Combi-40+ Medel Cochlear Implant

ENT 318 Artificial Organs Physiology of Ear

Labrynthitis. It causes a delicate structure deep inside your ear called the labyrinth to become inflamed, which affects your hearing and balance.

The Auditory Brainstem Implant. Manchester Royal Infirmary

Modifying radiology protocols for cochlear implant surgery in a government sponsored scheme: Need of the hour

Presentation On SENSATION. Prof- Mrs.Kuldeep Kaur

Jack Noble, PhD, René Gifford, PhD, Benoit Dawant, PhD, and Robert Labadie, MD, PhD

Very far-advanced otosclerosis: stapedotomy or cochlear implantation

Three-Dimensional Eye-Movement Responses to Surface Galvanic Vestibular Stimulation in Normal Subjects and in Patients

A hearing prosthesis for severe perceptive deafness Experimental studies

research directions Cochlear implant G.M.CLARK FREQUENCY CODING ELECTRICAL RATE STIMULATION - PHYSIOLOGY AND PSYCHOPHYSICS Department ofotolaryngology

Clinical Commissioning Policy: Auditory brainstem implant with congenital abnormalities of the auditory nerves of cochleae

Clinical Workflow. White Paper No. 35 / 2016

HEARING AND COCHLEAR IMPLANTS

Manchester Paediatric Cochlear Implant Programme

9/27/2018. Type of Hearing Loss. Type of Hearing Loss. Type of Hearing Loss

COCHLEAR IMPLANTS Aetiology of Deafness. Bruce Black MD

3/20/2017. D. Richard Kang, MD, FACS, FAAP Pediatric Otolaryngology Director, ENT Institute Boys Town National Research Hospital

Difficult Cases: Controversies in Cochlear Implantation

Complete Cochlear Coverage WITH MED-EL S DEEP INSERTION ELECTRODE

NATIONAL INSTITUTE FOR CLINICAL EXCELLENCE

Temporal bone imaging in osteogenesis imperfecta patients with hearing loss

Pediatric Temporal Bone

IN THE UNITED STATES PATENT AND TRADEMARK OFFICE UTILITY APPLICATION FOR UNITED STATES PATENT FOR

NERVE ENDINGS OF THE ORGAN OF CORTI AUTHORS: DOMINGGUS MANGAPE DEPARTMENT OF OTOLARYNGOLOGY HIROSHIMA UNIVERSITY

COM3502/4502/6502 SPEECH PROCESSING

Ear. Utricle & saccule in the vestibule Connected to each other and to the endolymphatic sac by a utriculosaccular duct

Laryngology and Otology

Surgeon Oriented Preoperative Radiologic Evaluation in Cochlear Implantation - Our experience with a Proposed Checklist

Anatomy of the Ear Region. External ear Middle ear Internal ear

NIDCD NATIONAL TEMPORAL BONE, HEARING AND BALANCE PATHOLOGY RESOURCE REGISTRY

Definition Slides. Sensation. Perception. Bottom-up processing. Selective attention. Top-down processing 11/3/2013

= add definition here. Definition Slide

Development of Silicon Microelectrodes for Cochlear Implant Technology

Cochlear implants. Carol De Filippo Viet Nam Teacher Education Institute June 2010

Scala Tympani Cochleostomy II: Topography and Histology

Michigan Ear Institute

Chapter 11: Sound, The Auditory System, and Pitch Perception

Kirsten Zernask-Cebek Doralice Ferreira. Cochlear Implants

Implants for surgery Active implantable medical devices. Part 7: Particular requirements for cochlear implant systems

UP Bioengineering Our people

For Professionals. SYNCHRONY System In Sync with Natural Hearing

(12) Patent Application Publication (10) Pub. No.: US 2004/ A1

Otoconia: Calcium carbonate crystals Gelatinous mass. Cilia. Hair cells. Vestibular nerve. Vestibular ganglion

Basic Fitting and Evaluation Parameters of a Newly Designed Cochlear Implant Electrode

The Sense Organs 10/13/2016. The Human Eye. 1. Sclera 2. Choroid 3. Retina. The eye is made up of three layers:

Descriptions of NDT Projects Fall 2004 October 31, 2004

Our Experience with AB HiFocus MSE Cochlear Implant from Laboratory to OR: Electrode and Access Variables

Senses Other Than Vision. Hearing (Audition) Transmission of Vibrations

Optical cochlear implant project

Implantable Treatments for Different Types of Hearing Loss. Margaret Dillon, AuD Marcia Adunka, AuD

A&P 1. Ear, Hearing & Equilibrium Lab. Basic Concepts. Pre-lab Exercises

Quantitative Electrophysiology

Structure, Energy Transmission and Function. Gross Anatomy. Structure, Function & Process. External Auditory Meatus or Canal (EAM, EAC) Outer Ear

For Professionals. SYNCHRONY EAS System. In Sync with Natural Hearing

College of Medicine Dept. of Medical physics Physics of ear and hearing /CH

Peter S Roland M.D. UTSouthwestern Medical Center Dallas, Texas Developments

Effects of Remaining Hair Cells on Cochlear Implant Function

THE EAR AND HEARING Be sure you have read and understand Chapter 16 before beginning this lab. INTRODUCTION: hair cells outer ear tympanic membrane

Three-dimensional finite element analysis of the human middle ear and an application for clinics for tympanoplasty

Electrode Trauma Assessed by Microdissection

SPECIAL SENSES. Anatomy & Physiology

Ms Melissa Babbage. Senior Audiologist Clinic Manager Dilworth Hearing

A&P 1. Ear, Hearing & Equilibrium Lab. Basic Concepts. These notes follow Carl s Talk at the beginning of lab

Effects of Remaining Hair Cells on Cochlear Implant Function

Chapter 17, Part 2! The Special Senses! Hearing and Equilibrium!

Chapter 17, Part 2! Chapter 17 Part 2 Special Senses! The Special Senses! Hearing and Equilibrium!

Can You Hear Me Now?

(Thomas Lenarz) Ok, thank you, thank you very much for inviting me to be here and speak to you, on cochlear implant technology.

MECHANISM OF HEARING

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion

PAEDIATRIC COCHLEAR IMPLANT SURGERY

Glossary For Parents. Atresia: closure of the ear canal or absence of an ear opening.

Chapter 13 Physics of the Ear and Hearing

Transcription:

Visualisation of the Cochlea Implant/Tissue Interface Christopher Wong 1, 4, Ian S. Curthoys 2, Stephen O Leary 3,4, Allan S. Jones 1 1 Australian Centre for Microscopy and Microanalysis, University of Sydney, NSW Australia, Christopher.wong@sydney.edu.au 2 School of Psychology, University of Sydney, NSW, Australia. 3 Department of Otolaryngology, University of Melbourne, VIC, Australia 4 The HEARing CRC, Melbourne, VIC, Australia Aims The cochlear implant is an electroneural implanted device which helps to restore communication in patients with profound auditory deafness. The implant, works on the concept of direct electrical stimulation of the spiral ganglion cells, within the cochlea. The cochlea is a snail-like coiled structure, apart of the inner-ear labyrinth; its role is to convert hydro-dynamic vibrations to electrochemical signals that travel up the auditory nerves to the brain. The electrode array of the cochlear implant is inserted into either, the round window or through a cochleostomy surgically drilled anterior-inferior to this structure. Insertion of the electrode array is without visual guidance and this may sometimes lead to damage to the delicate receptor structures within. Such damage may affect performance or result in complications such as: bleeding, meningitis, tinnitus, vertigo and poor hearing results (Kempf et al. 1999). Development of optimal insertional procedures, including the ability to assess the precise location of the electrode array and changes and /or damages caused during insertion is of high priority in the field of cochlea implantation. Histological techniques have been the traditional approach towards assessment of post-operative positioning of the electrode array and structural displacement within the cochlea. Samples are dehydrated, embedded in resin, sectioned and stained. The main limitation to this technique is the lack of 3D configuration between sections due to information loss from sectioning. The conventional approach of clinical CT scanners to visualise the implant within the cochlea has been limited, due to both low resolution (>300µm) and the metallic nature of the device. The low resolutions of clinical CT mean that delicate membranes of the inner ear are not visually resolved (Aschendorff, A., et al. 2004). With the development of microct systems capable of sub micron (<20µm) resolution and contrast staining techniques, detailed visualisation of the inner labyrinthine structures along with membranes have been successful (Uzun, H., Curthoys, I.S., Jones, A.S., 2006, Uzun-Coruhlu, H., Curthoys, I.S., and Jones, A.S., 2007). However when the sample contains metallic components (Platinum, Platinum alloys) within implanted electrode arrays, x-ray interaction causes scattering artefacts. Such scattering often masks the underlying nature of the tissue structures surrounding the implant, leading to imprecise analysis of the implant-tissue interface. To overcome this problem we are developing electrolytic processing to dissolve or partially dissolve the implant in-situ. Thereby minimising or completely removing most of the metal components which impede good visualization of the tissue-implant interface.

Method Two different electrolytes were utilised in experimentation; Polyethylene glycol 200 (50/50vol. 50%EtOH, 0.5M NaCl) and Karnovsky s fixative (3% Paraformaldehyde, 0.5% Glutaraldehyde, 0.1M NaCl, PBS). Experimentation on the electrolytic dissolution of Platinum involved a platinum wire (200µm) which acted as the anode and a carbon rod as the cathode electrode. The Platinum wire electrode was driven by a function generator delivering unbalanced biphasic pulses with an duration of 15ms and a repetition of 50 pulses per second, respective charge and current were; Karnovsky s: 5.88V, 85.4mA and PEG200: 5.11V, 85.7mA. In experimentation which simulated implant insertion, a Platinum wire was pierced through a 10X10X10mm cow muscular tissue, prepared via Karnovsky s fixation or Guinea Pig (GP) brain tissue, prepared via intracardiac perfusion with Karnovsky s fixative. With charge and current settings; Karnovsky s cow muscle: 6.34V, 62.2mA, PEG200 cow muscle: 6.25V, 80.3mA, Karnovsky s GP brain: 2.46V, 1.2mA, PEG200 GP brain: 3V, 2.4mA. Further experimentation aiming to simulate insertion of the electrode array ultilising the full Guinea Pig temporal bone was investigated. A Pt wire was inserted into the GP cochlea via the vestibular fenestra. Specimen was immersed in PEG200 electrolyte with electrolytic parameters: 8.86V and 30.2mA. Results In both electrolytes (PEG and Karnovsky s fixative) Platinum wire was successfully dissolved within 24hrs. Implantation simulation experimentation gave varying results. MicroCT analysis showed in both cow muscle samples, partial dissolution of the Pt wire with regions of full electrolytic dissolution (Fig.1, 2). MicroCT scans of the specimens showed scatter-free tissue conformation, whilst scattering still occurred where Pt was present. In initial tests for the GP brain tissue experimentation; partial dissolution of the pt was evident in Karnovsky s specimen (Fig. 3), MicroCT scan shows extensive scattering at region where Pt wire was still embedded. The PEG200 specimen showed full electrolytic dissolution of the wire, resulting in scatter free imaging from the MicroCT (Fig. 4). GP temporal bone experimentation, showed scattering in initial scans, where Pt wire is inserted into the cochlea. The Pt wire within the cochlea was dissolved electrolytically but the challenge remains in controlling the amount of displacement to surrounding tissue due to gas evolution during electrolysis.

Fig. 1. Absorption radiograph of a Platinum wire pierced through a cow muscle tissue. Red indications show region of partial dissolution of wire in PEG200 electrolyte. Specimen was scanned at 80kV, 124µA, with 17µm resolution at 10 o. Fig. 2. Absorption radiograph of a 200µm Platinum wire pierced through Bovine muscle tissue. Red indications shows the regions of partial and full dissolution of the wire within the specimen in Karnovsky s fixative electrolyte. Specimen was scanned at 59kV, 167µA with 17µm resolution at 13 o.

Fig.3. Absorption radiograph of a Platinum wire pierced through Guinea Pig Brain tissue. Regions of full electrolytic dissolution (bottom right) and minimal dissolution (top right) within the specimen are marked by corresponding dotted lines. Specimen was scanned at 62kV, 161µA, with 17µm resolution at 10 o.

Fig. 4. The absorption radiograph and reconstructed axial slice of Guinea Pig brain specimen. The axial slice image corresponds to the sample position as marked by the dotted line. The hole (approx. 500µm) seen in the axial scan marks the fully dissolved platinum wire position within the specimen in PEG electrolyte. Specimens scanned at 64kV, 155µA with 17µm resolution at 10 o. Conclusion Initial testing of the electrolytic dissolution of implants shows promise. Full platinum dissolution was previously thought to be impossible due to noble metal passivation preventing full electrolytic dissolution. This however is not the case. Full dissolution is possible using unbalanced biphasic current and suitable electrolytes. This opens up the possibility of visualizing the inner ear membranes in animal models used for implant studies. At this point in time further modification to the dissolution parameters are required to minimize tissue damage whilst still allowing removal of the implant material. References: 1. Kempf, H.G., Johann, K. and Lenarz, T., Complications in pediatric cochlear implant surgery, Eur. Arch. Otorhinolaryngol., 256:128-132, 1999. 2. Aschendorff, A., Kubalek, R., Hochmuth, A., Blink, A., Kurtz, C., Lohnstein, P., Klenzner, T. and Laszig, R., Imaging prodedures in cochlear implant patients evaluation of different radiological techniques, Acta Oto- Laryngologica, 552: 46-49, 2004. 3. Uzun, H., Curthoys, I.S. and Jones, A.S., A new approach to visualizing the membraneous structures of the inner ear high resolution X-ray, microtomography. 4. Uzun-Coruhlu, H., Curthoys, I.S. and Jones, A.S., Attachment of the utricular and saccular maculae to the temporal bone, Hearing Research, 233: 77-85, 2007.