Fast Separation of Triacylglycerols in Oils using UltraPerformance Convergence Chromatography (UPC 2 )

Similar documents
Analysis of the Non-Ionic Surfactant Triton-X Using UltraPerformance Convergence Chromatography (UPC 2 ) with MS and UV Detection

Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis

Lipid Class Separation Using UPC 2 /MS

Method Development for the Analysis of Endogenous Steroids Using Convergence Chromatography with Mass Spectrometric Detection

Rapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer

Comparison of a UPLC Method across Multiple UHPLC Systems

Rapid Lipid Profiling of Serum by Reverse Phase UPLC-Tandem Quadrupole MS

Rapid Quantitative Analysis of Cannabidiol from Consumer Products Using UltraPerformance Convergence Chromatography

A Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

Matrix Factor Determination with the Waters Regulated Bioanalysis System Solution

[ APPLICATION NOTE ] Profiling Mono and Disaccharides in Milk and Infant Formula Using the ACQUITY Arc System and ACQUITY QDa Detector

Analysis of Food Sugars in Various Matrices Using UPLC with Refractive Index (RI) Detection

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

UPLC-MS/MS Analysis of Azole Antifungals in Serum for Clinical Research

The Application of UPLC/MS E for the Analysis of Bile Acids in Biological Fluids

Automated Lipid Identification Using UPLC/HDMS E in Combination with SimLipid

Profiling Flavonoid Isomers in Highly Complex Citrus Juice Samples Using UPLC Ion Mobility Time-of-Flight Mass Spectrometry

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

Jose Castro-Perez, Henry Shion, Kate Yu, John Shockcor, Emma Marsden-Edwards, Jeff Goshawk Waters Corporation, Milford, MA, U.S. and Manchester, UK

LC/MS Method for Comprehensive Analysis of Plasma Lipids

Meeting Challenging Requirements for the Quantitation of Regulated Growth Promoters Dexamethasone and Betamethasone in Liver and Milk

INTRODUCTION CH 3 CH CH 3 3. C 37 H 48 N 6 O 5 S 2, molecular weight Figure 1. The Xevo QTof MS System.

Removal of Triton X-100 from Plasma Samples Using Mixed-Mode Solid Phase Extraction (SPE)

[ application note note ] ]

Analysis of N-Linked Glycans from Coagulation Factor IX, Recombinant and Plasma Derived, Using HILIC UPLC/FLR/QTof MS

John P. McCauley and Rui Chen Waters Corporation, Milford, MA, USA INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEY WORDS

A NOVEL METHOD OF M/Z DRIFT CORRECTION FOR OA-TOF MASS SPECTROMETERS BASED ON CONSTRUCTION OF LIBRARIES OF MATRIX COMPONENTS.

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column

John Haselden 1, Gordon Dear 1, Jennifer H. Granger 2, and Robert S. Plumb 2. 1GlaxoSmithKline, Ware, UK; 2 Waters Corporation, Milford, MA, USA

[ APPLICATION NOTE ] The Separation of 8 -THC, 9 -THC, and Their Enantiomers by UPC 2 Using Trefoil Chiral Columns INTRODUCTION APPLICATION BENEFITS

Andrea Perissi Specialista Applicativo, Waters Italia Waters Corporation 1

USP Method Transfer of Ziprasidone HCl from HPLC to UPLC

[ APPLICATION NOTE ] High Sensitivity Intact Monoclonal Antibody (mab) HRMS Quantification APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

Fast determination of residual glycerol and glycerides in biodiesel by SFC/MS using the Agilent 1260 Infinity Analytical SFC System

CHARACTERIZATION AND DETECTION OF OLIVE OIL ADULTERATIONS USING CHEMOMETRICS

A UPLC/MS Approach for the Diagnosis of Inborn Errors of Metabolism

Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection INTRODUCTION

Analysis of Rosuvastatin in Dried Blood Spot and Plasma Using ACQUITY UPLC with 2D Technology

A High Sensitivity UPLC/MS/MS Method for the Analysis of Clopidogrel and Clopidogrel Carboxylic Acid Metabolite in Human K 2 EDTA Plasma

A RAPID AND SENSITIVE UPLC/UV/MS METHOD FOR SIMVASTATIN AND LOVA S TAT IN IN SU P P O RT O F C L E A NING VA L I DAT IO N S T U DIES

Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

[Application Note] TOXICOLOGY SCREENING BY UPLC/PDA IN COMBINATION WITH AN EXTENSIVE COMPOUND LIBRARY

Application Note. Authors. Abstract. Petrochemical

Three and Four Mass Spectrometers t in Parallel for Lipid Analysis How Many Instruments are Enough?

Marc Plante, Bruce Bailey, and Ian N. Acworth Thermo Fisher Scientific, Chelmsford, MA, USA

THERMAL STABILITY OF TRIACYLGLYCEROLS IN EDIBLE OILS & TRIOLEIN MODEL SYSTEMS IN THE PRESENCE OF -CAROTENE. Alam Zeb, Michael Murkovic

GlycoWorks Sample Preparation Consumables

Rapid Analysis of Bisphenols A, B, and E in Baby Food and Infant Formula Using ACQUITY UPLC with the Xevo TQD

Supplementary Information

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases

The HPLC Preparative Scale-Up of Soybean Phospholipids Application

Analysis of Phenolic Antioxidants in Edible Oil/Shortening Using the PerkinElmer Altus UPLC System with PDA Detection

LC-Based Lipidomics Analysis on QTRAP Instruments

ApplicationNOTE EXACT MASS MEASUREMENT OF ACTIVE COMPONENTS OF TRADITIONAL HERBAL MEDICINES BY ORTHOGONAL ACCELERATION TIME-OF-FLIGHT.

March 2012 October 2013

Lipidomic Analysis by UPLC-QTOF MS

[ APPLICATION NOTE ] UPLC-MS/MS Analysis of 45 Amino Acids Using the Kairos Amino Acid Kit for Biomedical Research INTRODUCTION APPLICATION BENEFITS

Chemical Analysis Business Operations Waters Corporation Milford MA

Supporting Information

Identification and Quantification at ppb Levels of Common Cations and Amines by IC-MS

The Development of LC/MS Methods for Determination of Polar Drugs of Abuse in Biological Samples

[APPLICATION NOTE] DETERMINATION OF AMINO ACIDS IN BEERS USING THE UPLC AMINO ACID ANALYSIS SOLUTION

A Metabolomics Approach to Profile Novel Chemical Markers for Identification and Authentification of Terminalia Species

Core E Analysis of Neutral Lipids from Human Plasma June 4, 2010 Thomas J. Leiker and Robert M. Barkley

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

Analysis of several common. organic acids in tobacco leaf, snus, and moist snuff

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Quantification of Budesonide Using UPLC and Xevo TQ-S

The Raptor HILIC-Si Column

Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids

The Development of LC/MS Methods for Determination of MDMA (Ecstasy) and Metabolites in Biological Samples

2D-LC as an Automated Desalting Tool for MSD Analysis

[ APPLICATION NOTE ] Oasis PRiME HLB Cartridge for Cleanup of Infant Formula Extracts Prior to UPLC-MS/MS Multiresidue Veterinary Drugs Analysis

Identification of Steroids in Water by Ion Trap LC/MS/MS Application

Providing a Universal, One-step Alternative to Liquid-Liquid Extraction in Bioanalysis

Lipid Analysis. Andréina Laffargue, IRD CRYMCEPT Montpellier workshop, October 17th Introduction to lipid structures

Determination of red blood cell fatty acid profiles in clinical research

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS

Impact of Reversed-Phase Chiral Chromatography on the LC-MS Analysis of Drugs in Biological Fluids

Determination of Amantadine Residues in Chicken by LCMS-8040

Challenges in Developing an Ultra-Sensitive Bioanalytical Method for Ethinylestradiol in Human Plasma

Phospholipid characterization by a TQ-MS data based identification scheme

Neosolaniol. [Methods listed in the Feed Analysis Standards]

SEPARATION OF BRANCHED PFOS ISOMERS BY UPLC WITH MS/MS DETECTION

Automated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS

Development of a High Sensitivity SPE-LC-MS/MS Assay for the Quantification of Glucagon in Human Plasma Using the ionkey/ms System

SUPPORTING INFORMATION. Characterization of Triacylglycerol Enantiomers Using. Chiral HPLC/APCI-MS and Synthesis of Enantiomeric.

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column

Lipid Analysis by Evaporative Light Scattering Detection

Metabolomic and Lipidomic Research in Diabetes and Obesity 08/07/2013

SUPPLEMENTARY INFORMATION

Polymer Additive Analysis by EI and APCI

Edgar Naegele. Abstract

Separation of 15 Underivatized Saccharide and Sialic Acid USP Standards

ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS

Transcription:

Fast Separation of Triacylglycerols in Oils using UltraPerformance Convergence Chromatography (UPC 2 ) Mehdi Ashraf-Khorassani, 1 Larry T. Taylor, 1 Jinchuan Yang, 2 and Giorgis Isaac 2 1 Department of Chemistry, Virginia Tech, Blacksburg, VA 2 Waters Corporation, Milford, MA APPLICATION BENEFITS No analyte pre-column derivatization No column coupling No mobile phase additives Fast analysis time of 10 minutes INTRODUCTION UltraPerformance Convergence Chromatography (UPC 2 ) is a novel technology that applies the performance advantages of UPLC to supercritical fluid chromatography (SFC). Combining the use of supercritical CO 2 with sub-2-µm particle columns, UPC 2 represents an analysis technique that is orthogonal to reversed-phase LC and can be used to solve many troublesome separations that challenge conventional LC or GC analyses. It also generates less solvent waste as compared to liquid chromatography. These benefits have led to interest in applying this technology to various industrial analytical areas. The established UPC 2 /MS approach has potential application in lipidomics as a complementary method alongside LC/MS and GC/MS, as it can separate both polar and non-polar lipids, and in many cases does not require derivatization of lipids to improve detection limits and peak shape. Studies using UPC 2 coupled with ultraviolet (UV) detection, mass spectrometry (MS), and evaporative light scattering (ELS) detection for the separation of triacylglycerols in tobacco, corn, sesame, and soybean seed oils are presented in this application note. A single unendcapped C 18 column with acetonitrile-modified CO 2 was used for the separation of all seed oils. WATERS SOLUTIONS ACQUITY UPC 2 System ACQUITY UPC 2 PDA Detector ACQUITY UPLC ELS Detector Xevo G2 Q-Tof MS ACQUITY UPC 2 HSS C 18 SB Column KEY WORDS SFC, convergence chromatography, CC, UPC, 2 triacylglycerols, TAG, oils, tobacco, edible oils, ELS, MS, Q-Tof, UV 1

EXPERIMENTAL Sample preparation Tobacco seed oil was obtained from R.J. Reynolds Tobacco Co. (Winston-Salem, NC); soybean oil, corn oil, and sesame seed oil were obtained from Sigma Aldrich (St. Louis, MO). 5 of the different oils were dissolved in dichloromethane/methanol (1/1) for UV and ELS and 0.1 for the Xevo G2 Q-Tof MS. Method conditions System: ACQUITY UPC 2 MS conditions MS: Xevo G2 Q-Tof Column: ACQUITY UPC 2 HSS C 18 SB, 1.8 µm, 3.0 x 150 mm ABPR: 1500 psi Column temperature: 25 C Injection volume: 2-8 µl (UV and ELSD), 0.5 µl (MS) Sample solvent: Dichloromethane/methanol (1/1) Flow rate: 1-2 ml/min Ionization mode: ESI positive Capillary voltage: 3.0 kv Cone voltage: 30 V Source temperature: 150 C Desolvation temp.: 500 C Cone gas flow: 10 L/h Desolvation gas flow: 600 L/h Acquisition range: 40 to 1200 m/z Mobile phase A: Compressed CO 2 Mobile phase B: Acetonitrile or 90/10 acetonitrile/meoh Make up solvent: Make up flow rate: Gradient: IPA for ELSD and MeOH in 10 mm ammonium acetate for MS 0.2 ml/min A- 98/2 to 80/20 in 18 min for ELSD/UV and 18 min for MS B- 90/10 to 50/50 in 10 minutes for MS Detectors: ACQUITY UPC 2 PDA 200-400 nm, Ref. 40000 nm ACQUITY ELS Nebulizer: Cooling, drift tube: 50 C, Gas pressure: 40 psi and Gain 10 2

RESULTS AND DISCUSSION From the perspective of current applied lipid research, UPC 2 is a complementary and perhaps preferred technique to gas chromatography (GC) and high performance liquid chromatography (HPLC) for metabolic profiling of lipids. 1 The use of UPC 2 /MS allows for high throughput and exhaustive analysis of diverse lipids, leading to potential application in lipidomics. Currently, there is much interest in rapid characterization of triacylglycerols (TAGs). TAGs are natural compounds produced by the esterification of glycerol with fatty acids. In humans, TAGs serve as a source of energy stored in fat tissues and they form a thermal and mechanical protective layer around important organs. 2 Furthermore, TAGs are the source of essential fatty acids such as linoleic and linolenic acids. Figure 1 shows UV, ELSD, and MS chromatograms for the separation of TAGs in soybean oil. All of the effluent first passes through the PDA flow cell and then to the back pressure regulator and the ELSD using the PEEK ELSD splitter kit (205001048). Each gradient separation was performed at 25 C with an ACQUITY UPC 2 HSS C 18 SB Column and a mobile phase of acetonitrile-modified CO 2. Near baseline peak resolution was observed on a single ACQUITY UPC 2 HSS C 18 SB, 1.8 µm, 3.0 x 150 mm Column in approximately 16 minutes. Baseline stability was excellent, even under gradient conditions, demonstrating the stability of the system and allowing reproducible detection and possible quantitation of lower level peaks in the samples. 0.57 AU 5.0e-1 UV 11.19 10.93 11.78 10.69 12.06 12.49 14.21 0.0-0.00 18.00 LSU 150.000 100.000 ELSD 11.24 11.83 12.11 10.97 50.000 12.54 13.39 0.000-0.00 18.00 11.40 11.90 MS 11.11 12.71 13.22 10.86 14.26 15.70-0.00 18.00 Figure 1. Analysis of soybean oil using UPC 2 with CH 3 CN as the modifier. Chromatography conditions: Gradient elution: 2 to 20 CH 3 CN in 18 min, Flow: 1.5 ml/min, Column temp.: 25 C. 3

The conditions from Figure 1 were used to separate and profile TAGs in tobacco seed oil, soybean oil, corn oil, and sesame seed oil. Data were acquired in UPC 2 /MS E mode, an unbiased Tof acquisition method in which the mass spectrometer switches between low and high energy on alternate scans for structural elucidation and identification. In all cases, distinct profiles and excellent separations were obtained for all oil types when using UPC 2 with both MS and ELS detection. Figure 2 shows the UPC 2 /MS separation and detection of different TAGs in different oils using UPC 2 /MS E. TAGs were identified using accurate mass spectra collected by QTof MS with MS E and Waters TransOmics Informatics. In positive ion mode MS E low energy, TAGs produce intact ammonium adduct [M+NH 4 ] + precursor exact mass when ammonium acetate is present in the make-up solvent. In MS E high energy, abundant fragment ions are produced corresponding to the neutral loss of one of the sn-1, sn-2, or sn-3 fatty acids plus ammonia. 11.39 11.93 12.11 Tobacco seed oil 12.49 13.23 11.11 13.93 16.83 Sesame seed oil 11.36 11.88 12.45 13.09 13.35 13.87 14.68 15.10 11.40 11.92 12.11 Corn oil 11.14 13.17 13.41 13. 14.29 11.40 11.90 Soybean oil 11.11 12.71 13.22 13.93 10.86 14.26 15.70 Figure 2. UPC 2 -MS analysis of different oils using CH 3 CN as a modifier. Chromatography conditions: Gradient elution: 2 to 20 CH 3 CN in 18 min, Flow: 1.5 ml/min, Column temp.: 25 C. 4

For example, Figure 3 shows the ion at m/z 874.7823 corresponding to 52:3 TAG (calculated fatty acid carbon atom: total number of double bonds), which can be identified as POL due to the presence of abundant fragment ions at m/z 575.5038, 577.5201, and 601.5186, corresponding to the neutral loss of fatty acyl groups P, O, and L plus ammonia, respectively. 4 Table 1 shows a list of all identified TAGs in the different oils based on the low energy precursor exact mass and corresponding high energy fragment ions. 100 [M-16:0] + 601.5186 [M-18:2] + 577.5201 [M-18:1] + 575.5038 MS E high energy 0 500 525 550 575 600 625 650 675 700 725 750 775 800 825 850 875 900 925 0 m/z 100 602.5237 [M+NH 4 ] + 874.7823 874.7883 MS E low energy 875.7882 0 500 525 550 575 600 625 650 675 700 725 750 775 800 825 850 875 900 925 0 m/z Figure 3. Example MS E spectra of TAG species identified as POL, which elutes at 12.71 min using the conditions in Figures 1 and 2. 5

Ret. time, min. Soybean oil Corn oil Sesame oil Tobacco seed oil 10.86 LnLnL 11.11 LnLL LnLL LnLL LnLL 11.40 LLL LLL LLL LLL 11.60 OLLn OLLn OLLn 11.78 PLLn 11.90 OLL OLL OLL OLL 12.11 PLL PLL PLL PLL 12.32 POLn POLn POLn 12.49 OOL OOL OOL OOL 12.71 POL POL POL POL 13.00 PPL PPL PPL PPL 13.08 OOO OOO OOO 13.22 SLL SLL SLL SLL 13.40 POO POO POO 13.93 SOL SOL SOL SOL 14.26 PSL PSL PSL PSL 14.73 SSL SSL SSL SSL 15.14 PSO PSO PSO 15.70 PSA PSA PSA Table 1. List of detected triacylglycerols in each seed oil with corresponding retention time via UPC 2 -MS (using conditions from Figures 1 and 2) In an attempt to reduce the analysis time of the TAGs, a faster gradient elution was used. Figure 4 shows the separation of soybean oil using two different gradient profiles with acetonitrile as a modifier. With the faster gradient elution (Figure 4A), all the components were eluted in less than nine minutes. With slower gradient elution (Figure 4B), all components eluted in less than 16 minutes. Little resolution was lost when the faster gradient was used, thus increasing the throughput of the UPC 2 /MS method. 4.74 5.13 5.28 4.52 5.64 5.83 A 6.10 4.31 6.79 7.16 7.758.34 11.11 10.86 11.40 11.90 12.11 12.71 13.22 13.93 14.26 B 15.70 Figure 4. Analysis of soybean oil at 25 C using UPC 2 -MS with CH 3 CN as the modifier. Chromatography conditions A: 2 to 20 CH 3 CN in 18 min, Flow: 1.5 ml/min Chromatography conditions B: 10 to 50 CH 3 CN in 10 min Flow: 1.2 ml/min Also, a mobile phase modifier of acetonitrile and methanol (9:1) was tested under the same chromatographic conditions. 6

Overall retention time decreased approximately 5 minutes with minimal loss in peak resolution (Figure 5). This data indicates that changing the gradient profile, flow rate, and mobile phase modifier can be performed to optimize the separation based on the type of TAG analysis required. All of these parameters are compatible with MS detection, thus allowing positive identification of all TAG species in oils. 7.67 1250.000 1000.000 ELSD 7.31 LSU 750.000 500.000 7.12 8.14 8.59 250.000 9.09 0.000 2.50 5.00 7.50 10.00 12.50 15.00 17.50 0.56 AU 4.0e+1 3.0e+1 2.0e+1 0.60 UV 7.08 6.92 7.26 7.63 8.08 8.53 9.04 10.18 1.0e+1 10.58 0.0 0.81 2.31 2.50 5.00 7.50 10.00 12.50 15.00 17.50 Figure 5. Analysis of soybean oil using UPC 2 with CH 3 CN/MeOH (9:1) as the modifier. Chromatography conditions: 2 to 20 CH 3 CN in 18 min, Flow: 1.5 ml/min, column temp: 25 C. 7

CONCLUSIONS UltraPerformance Convergence Chromatography, in combination with sub-2-µm particles and UV, ELS, and MS detection, is a valuable technique for the determination of triacylglycerol composition in a variety of seed oils. Excellent resolution on a single column in as little as 10 minutes serves as an improvement on past generations of SFC instrumentation. This methodology can be used as a tool for rapid characterization and profiling a suite of acylglycerols from different oil sources. References 1. Bamba T, Lee J.W., Matsubara A, Fukusaki E. Metabolic Profiling of Lipids by Supercritical Fluid Chromatography/Mass Spectrometry. J. Chromatogr. A, 1250 (2012); 212. 2. Grand-Guillaume Perrenoud A, Veuthey J-L, Guillarme D. Comparison of Ultra-High Performance Supercritical Fluid Chromatography and Ultra-High Performance Liquid Chromatography for the Analysis of Pharmaceutical Compounds. J. Chromatogr. A, 1266 (2012); 158. 3. Zhou Q, Gao B, Zhang X, Xu Y, Shi H, Yu L. Chemical Profiling of Triacylglycerols and Diacylglycerols in Cow Milk Fat by Ultra-Performance Chromatography Combined with a Quadrupole Time-Of-Flight Mass Spectrometry. Food Chemistry 143 (2014); 199. 4. Murphy R, James P, McAnoy A, Krank J, Duchoslav E, Barkley R. Detection of the Abundance of Diacylglycerol and Triacylglycerol Molecular Species in Cells Using Neutral Loss Mass Spectrometry. Anal. Biochem. 366 (2007); 59. Waters, The Science of What s Possible, ACQUITY, UPC, 2 and Xevo are registered trademarks of Waters Corporation. ACQUITY UPC, 2 UltraPerformance Convergence Chromatography, TransOmics, and Q-Tof are trademarks of Waters Corporation. All other trademarks are property of their respective owners. 2014 Waters Corporation. Produced in the U.S.A. January 2014 720004871EN AG-PDF Waters Corporation 34 Maple Street Milford, MA 01757 U.S.A. T: 1 508 478 2000 F: 1 508 872 1990 www.waters.com