Effect of light curing units on physical properties of composites

Similar documents
Influence of the light curing unit and thickness of residual dentin on generation of heat during composite photoactivation

Effect of Reduced Exposure Times on the Microhardness of Nanocomposites Polymerized by QTH and Second-generation LED Curing Lights

Comparison of Temperature Changes in the Pulp Chamber Induced by Various Light Curing Units, In Vitro

Assistant Professor and Consultant, Department of Restorative Dental Science, College of Dentistry, Taibah University, Al Madinah Al

The Influence of Temperature on the Efficacy of Polymerization of Composite Resin

WHY PLASMA TECHNOLOGY?

Evaluation of a Second-Generation LED Curing Light

Comparison of the Heat Generation of Light Curing Units

Hardening of a dual-cure resin cement using QTH and LED curing units

Key words: Finite element analysis, composite resin, ceramic, temperature distribution, light polymerization unit.

Efficacy of New LED Light-Curing Units in Hardening of Class II Composite Restorations

Curious Curing. How do you know if you re getting the right output from your LCU? 50 JULY 2016 // dentaltown.com

The effect of a plastic-wrapped LED light curing unit and curing distance variances on diametral tensile strength of composite resin

Comparison of Quartz-Tungsten-Halogen, Light-emitting Diode, and Plasma Arc Curing Lights

Effectiveness of Second-generation Light-emitting Diode (LED) Light Curing Units

Light Conduction Capability of Different Light-Transmitting FRC Posts

EFFECT OF LIGHT CURING UNIT ON RESIN-MODIFIED GLASS-IONOMER CEMENTS: A MICROHARDNESS ASSESSMENT

Intensity output and effectiveness of light curing units in dental offices

The Effect of Soft-start Polymerization by Second Generation LEDs on the Degree of Conversion of Resin Composite

Polymerization of dual cured composites by different thickness

Effects of Different Temperatures and Storage Time on the Degree of Conversion and Microhardness of Resin-based Composites

Effect of Shade and Thickness of Porcelain Veneers on Depth of Cure of Light-Cured Resin-Based Luting Cement

Evaluation of Ocular Hazards from 4 Types of Curing Lights

Degree of conversion of two lingual retainer adhesives cured with different light sources

Curing efficiency of various resin-based materials polymerized through different ceramic thicknesses and curing time

Effect of light irradiation distance during intermediate. polymerization on depth of cure and hardness of. indirect composite

Vickers Hardness of Composite Resins Cured with LED and QTH Units

TRANSMITTANCE CHARACTERISTICS OF DIMETHACRYLATE RESIN BASED DENTAL COMPOSITES

The effect of light curing units, curing time, and veneering materials on resin cement microhardness y

Effect of light-curing method and indirect veneering materials on the Knoop hardness of a resin cement

Opacity and Color Changes of Light-Cured Ideal Makoo (IDM)

SDR has proven reliability in high C-factor cavities 2

Charisma Topaz PRODUCT INFORMATION. The three - in - one composite solution. Heraeus Kulzer Nordic AB

Effect of Time and Polymerization Cycle on the Degree of Conversion of a Resin Composite

J Lasers Med Sci 2016 Summer;7(3):

THE FIRST ALL CERAMIC-BASED FLOWABLE DIRECT RESTORATIVE

Degree of conversion and temperature rise during polymerization of composite resin samples with blue diodes

Research Article Surface Hardness of Resin Cement Polymerized under Different Ceramic Materials

Evaluation of Curing Light Distance on Resin Composite Microhardness and Polymerization

Temperature Rise Within the Pulp Chamber During Composite Resin Polymerisation Using Three Different Light Sources

Shear bond strength of dentin bonding agents cured with a plasma arc curing light

Influence of different light curing units on the bond strength of indirect resin composite restorations

Surface Hardness Properties of Resin-Modified Glass Ionomer Cements and Polyacid-Modified Composite Resins

Evaluation of degree of conversion and hardness of dental composites photoactivated with different light guide tips

Influence of Curing Rate of Resin Composite on the Bond Strength to Dentin

Effect of. Conversion Degree and Hardness of Dual-cured Resin Cement

Near-UV light detection

Quantifying Light Energy Delivered to a Class I Restoration

Until recently, the most popular light-curing unit. Effects of high-intensity curing lights on microleakage under orthodontic bands ORIGINAL ARTICLE

Acknowledgments Introduction p. 1 Objectives p. 1 Goals p. 2 History of Dental Materials p. 3 The Oral Environment p. 4 Characteristics of the Ideal

Effects of layering technique on the shade of resin overlays and the microhardness of dual cure resin cement

EFFECT OF CURING LIGHT DISTANCE ON MICROLEAKAGE AND COMPRESSIVE STRENGTH OF PEDIATRIC COMPOSITE RESTORATIONS

The desire to cure on demand has caused more orthodontic

Temperature changes in the pulpal chamber and the sealing performance of various methods of direct pulp capping of primary teeth

Transdental Photo-activation Technique: Hardness and Marginal Adaptation of Composite Restorations Using Different Light Sources

Glass Ionomers. Reputable, Durable, Long Lasting

FORM (A) CURRICULUM VITAE

Effect of cross infection control barriers used on the light-curing device tips on the cure depth of a resin composite

Up to date literature at your disposal to discover the benefits of laser dentistry

Comparison of Composite Curing Parameters: Effects of Light Source and Curing Mode on Conversion, Temperature Rise and Polymerization Shrinkage

Effects of Different Curing Lights on Microleakage in Resin- Based Composite Restorations

The Effect of Heat on the Surface Properties of Conventional Glass Ionomer Cements: SEM Evaluation

Effect of Ionising Radiation on Micro Hardness Property of Restorative Materials

Post-gel Shrinkage Strain and Degree of Conversion of Preheated Resin Composite Cured Using Different Regimens

Effect of resin thickness, and curing. micro-hardness of bulk-fill resin composites

Curing Effectiveness of Bulkfill Composites

The use and maintenance of visible light activating units in general practice

Shear Bond Strength of Orthodontic Brackets Cured with Different Light Sources under Thermocycling

Review Article Effect of Recurring Procedure on the Surface Micro hardness Values of Different Composite Resins

Department of Prosthodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand

The Effect of Shade and Curing Time on Depth of Cure (DOC) in Two Types of Composites, Polymerized with a Halogen Light Cure System

EVALUATION OF SIGNIFICANCE OF TIME IN PLACEMENT OF COMPOSITE OVER VARIOUS CALCIUM SILICATE BASED MATERIALS: AN IN-VITRO STUDY

Polymerization of a dual-cured cement through Empress 2 porcelain: LED curing light vs. halogen curing unit

A real leader takes you further.

Scientific Documentation

The Sof-Lex Finishing and Polishing System 3ESPE

A real leader takes you further.

Effect of Instruction on Dental Students Ability to Light-Cure a Simulated Restoration. Association survey, an estimated

The effect of light source distance on diametral tensile strength of nano particle composite

etching systems with mixing self-etching Etch & Rinse systems 3-year Water-storage Class-V Dentin Margin Integrity of Adhesives

Light curing in dentistry and clinical implications: a literature review

Shades: A1, A2, A3, A3.5, A4, B1, B2, B3, C2, C3, C4, D3, DB, OA2, OA3, OA3.5, OB2, Incisal, SL,SLO, SLT, YB

2011 Dental Materials Clinical Dentistry Survey

Effects of Different Light Curing Units/ Modes on the Microleakage of Flowable Composite Resins

In Vitro Evaluation of Fluorescence Stability of Different Composites and Dental Tissues Before And After Accelerated Aging

Continually Fluoride Releasing Aesthetic Dental Restorative Material

Bracket bond strength dependence on light power density. STAUDT, Christine Bettina, KREJCI, Ivo, MAVROPOULOS, Anestis. Abstract

Study the hardness and temperature changes during tooth bleaching using different Laser Sources

DH220 Dental Materials

Correlation Between the Amount of Linear Polymerization Shrinkage and Cuspal Deflection

Curriculum Vitae. Education. Experience in Clinic, Teaching, and Research

IN VITRO STUDY OF LIGHT RADIATION PENETRATION THROUGH DENTIN, ACCORDING TO THE WAVELENGTH

Changes in Degree of Conversion and Microhardness of

FLUORIDE RELEASING, BIOACTIVE, NANO-HYBRID COMPOSITE

AdperTM FiltekTM EliparTMSof-LexTM

FIVE THINGS YOU NEED TO KNOW ABOUT GLASS IONOMERS

Correlation between Linear polymerization shrinkage & tooth cuspal deflection

Effect of Different Thicknesses of Pressable Ceramic Veneers on Polymerization of Light-cured and Dual-cured Resin Cements

Surface Treatments that Demonstrate a Significant Positive Effect on the Shear Bond Strength of Repaired Resin-modified Glass Ionomer

LED vs Halogen Light-Curing of Adhesive-Precoated Brackets

Transcription:

VARIA Effect of light curing units on physical properties of composites Özcan Çakmakçioglu 1, Pinar Yilmaz 1, Bülent Topbaºi 2 Istanbul, Turkey Summary Objective. The objective of this study is to determine the polymerization efficiency of three light curing units on two different thicknesses of different composites. Material and method. Three commercial composite resins were used to prepare disk shaped specimens (10 mm x 2 mm and 10 mm x 3 mm ). All the specimens were light-polymerized for 40 seconds with three different light curing units at zero distance. 18 groups and 8 specimens for 1 group of light-cure composite at A1 shade were used in this study. Surface hardness was determined in top and bottom surfaces of each sample with Vickers hardness tester (Zwick). Results. Statistical analyses of the study were made by Kruskal Wallis test and Mann Whitney U test. The light curing units did not demonstrate any significant difference in top surfaces for all groups except for the samples cured with Halogen light. The best results were obtained for bottom surfaces when 2 mm samples of Supreme were exposed by Led 2 (Mean = 64.40 ± 12.27). The significantly high number of samples exposed with Led 2 shows the percentage ratio for bottom/top hardness values exceeded 80% (p<0.01). Also samples cured with halogen light showed significantly better bottom/top hardness ratio than the samples cured with Led 1 (p<0.05) Conclusion. The second generation Led technology shows a significantly better depth of cure from QTH (quartz tungsten halogen) lights without some drawbacks like heat transmission and limited effective lifetime. The maximum thickness for composite resins must be 2 mm, even curing with high intensity light sources. Also it should be taken into account that the composite resin filler type and composition may cause low polymerization efficiency due to limited light passing through the bottom surface. Key words: Light Curing, QTH, light intensity, microhardness, composite. Introduction Since 1970, light activated resin composite restoratives have been widely used in clinical dentistry. There has been a rapid increase in demand for esthetic restorative materials as well as light curing units since the introduction of single-paste light cured composites [1]. As the polymerization of light cured resins depends mainly on the characteristics and type of the radiation source used, a way to achieve better properties of the final restoration cured is the improvement of the curing unit. Visible light-curing units are an important part of modern adhesive dentistry. They are used to cure resin based composite restorative materials, resin modified glass ionomers, preventive pit and fissure sealants, certain bases and liners, core build-up materials and provisional restorative materials [2,3]. Visible light activated resin systems use a diketone absorber to create free radicals that initiate the polymerization process 1,2 DMD, PhD Student, Department of Operative Dentistry, Faculty of Dentistry, Marmara University, Istanbul 3 DDD, PhD, Professor, Department of Operative Dentistry, Faculty of Dentistry, Marmara University, Istanbul 41

[4,5]. Most dental photoinitiator systems use camphoroquinone as the diketone absorber, with the absorption maximum in the blue region of the visible light spectrum at a wavelength of 470 nanometers (nm) [6,7]. The most popular method of delivering blue light has been with halogen-based light curing units [8]. Despite their popularity, halogen technology light curing units used to polymerize dental materials have several drawbacks [9]. For example, halogen bulbs have a limited effective lifetime of approximately 40-100 h [10]. In addition, the LCU's bulb, reflector and filter degrade over time due to the high operating temperatures and the large quantity of heat, which is produced during the duty cycles. This results in a reduction of the LCU's curing effectiveness over time [11]. To overcome the problems inherent to halogen LCUs, solid-state light emitting diode (LED) technology has been proposed for curing light activated dental materials [12]. LCUs that use blue LEDs produce a narrow band of wavelengths, specifically chosen to excite the photoinitiators commonly used in dental resins [6,13]. LEDs last for thousands of hours, convert electricity into light more efficiently, and they produce less heat [6,14,15]. The first generation of LED curing lights, which often contained multiple LEDs, had a relatively low power output, and they did not perform as well as conventional QTH lights [13,16,17]. The second generation of LED curing lights delivers a different spectral distribution with a greater power output than the first generation lights and may therefore offer better performance and shorter curing times [18]. For the light cured materials it is obvious that the degree of polymerization is affected by the irradiation time and light intensity. The filler type size and translucency of the material can also affect the depth of cure [19]. As light passes through composite it is absorbed and scattered, attenuating the intensity and reducing the effectiveness of the light for resin polymerization. The objective of this study is to determine the polymerization efficiency of three light curing units on two different thicknesses of different composites. Material and method Three commercial composite resins (Admira, Voco; Supreme, 3M-ESPE; Carisma, Heraeus Kulzer) were used to prepare disk shaped specimens (10 mm x 2 mm and 10 mm x 3 mm). All the specimens were light polymerized for 40 seconds with three different light curing units (Led 1: Hilux, Ledmax 1; Led 2: Freelight 2, 3M-ESPE; QTH: Coltolux 75, Coltone) at zero distance. 18 groups and 8 specimens for 1 group of light-cure composite at A1 shade were used in this study. After the curing process the samples are stored in 100% humidity at 37 C degrees for 24 hours. Surface hardness was determined from top and bottom surfaces of each sample with Vickers hardness tester (Zwick). Before examination, a 250-gram load was applied to four different places for both surfaces. Results Statistical analyses of the study were made by Kruskal Wallis test and Mann Whitney U test. The light curing units did not show any significant difference in top surfaces for all groups except for the samples cured with Halogen light. Best results were gained from the samples of Supreme in 2 mm (p<0.01). Also samples cured with Led 2 in 3 mm Supreme show significantly better results than other composites (p<0.05). Led 1 shows significantly lower hardness values than Led 2 and QTH except for 3 mm samples of Carisma at bottom surfaces. There is no significant difference for all light curing units at 3 mm samples of 42

Table 1. Vickers Hardness Values Light Thickness Composite Source (mm) Carisma Supreme Ormoser p Ort. S.D. Ort. S.D. Ort. S.D. LED 1 2 Top 51.25 1.52 73.82 2.99 60.67 8.09 0.012* Bottom 30.67 5.10 35.15 10.93 26.30 2.32 0.537 3 Top 46.17 14.90 73.20 1.23 46.70 4.78 0.020* Bottom 35.87 9.73 21.30 0.94 19.17 1.62 0.010* LED 2 2 Top 56.30 4.46 77.52 4.48 53.48 3.11 0.019* Bottom 47.87 4.03 64.40 12.27 47.87 1.88 0.038* 3 Top 54.97 1.23 73.25 6.32 52.30 3.63 0.017* Bottom 45.22 2.21 52.75 13.87 39.15 3.72 0.174 HALOGEN 2 Top 68.87 1.94 88.52 11.79 57.90 3.79 0.007** Bottom 44.07 0.91 56.97 15.74 48.72 0.55 0.190 3 Top 60.32 17.04 66.35 4.82 53.35 5.94 0.292 Bottom 36.45 6.88 42.20 11.27 38.07 3.10 0.841 Carisma. Led 2 shows significantly better hardness values than QTH for all 2 mm samples except Ormocer. The best results were obtained for bottom surfaces when 2 mm samples of Supreme were exposed with Led 2 (Mean = 64.40 ± 12.27), (Table 1). Significantly high number of samples exposed with Led 2 shows the percentage ratio for bottom/top hardness values exceeded 80% (p<0.01). Also samples cured with halogen light are significantly better than the samples cured with Led 1 (p<0.05) (Table 2). Discussion Studies have demonstrated that lightcuring units can cause a temperature increase that could damage pulp [20]. Thermal transfer to pulp varies with the type of unit used during curing [21]. The depth of cure and surface microhardness has been related to the energy output of the light-curing unit [22]. Newer light-curing units have been designed to increase the light energy output, but increasing the light intensity could increase thermal transfer to pulp [23]. In addition, curing units that have lower polymerization efficiency can cause residual monomers; these monomers can pass through dentin tubules and result in irreversible pulpitis. For all these reasons we can say that the biological properties of dental materials may be affected by the curing unit used [24]. Due to the need for high output and less temperature rise, LED technology is the best alternative to conventional halogen bulb curing devices. The temperature rise during polymerization and heating Table 2. Top/Bottom Hardness Ratios Top/Bottom Led1 Led2 Halogen Percentages n % n % n % < %79 and lower 44 91.7 18 37.5 40 83.3 > %80 and higher 4 8.3 30 62.5 8 16.7 Total 48 100 48 100 48 100 43

from radiation was lower with LED compared to QTH curing [25]. The first generation LED curing devices has advantages such as low heat transmission and better wavelengths produced for composite polymerization but the results of our study showed that the Led 1 polymerization device has lower intensity than QTH units that overcome a lower polymerization efficiency. Our data supports the study of Kurachi et al. [26]. Also Dunn et al. [16] mentioned that the light output of commercially available diodes for resin-based composite polymerization still requires improvement to rival the adequacy of cure of halogen-based LCUs. Soh et al. [17] showed that the efficiency of Led 2 curing units is comparable to QTH devices at different type and thickness of composites. Also Yoon et al. [27] mentioned that the degree of conversion is influenced by three variables of material: depth from surface, light source and energy level. For each light curing unit and material, there was a linear relationship between the depth of cure and the logarithm of the amount of exposure, which is defined as the product of the irradiation and irradiation time [28]. They showed that Led 2 curing units exhibit better polymerization efficiency than others. Uhl et al [29] showed that the spectral output of the second-generation light emitting diodes fits better than the other light sources for polymerization of composite resins. They found out that at the thickness of 2 mm, second generation LED polymerization devices have better polymerization depth than other conventional polymerization devices. Fujibayashi et al. showed that at the same irradiance, LEDs perform as well as or better values than do halogen-based units [30,31]. In this study the hardness ratios showed that Led 2 curing units have equal or better performance than QTH devices up to the composite resin used. The polymerization of composites is affected by the wavelength of light, and the transmittance and absorbency of composites also depend on the wavelength of light [28]. Nomoto figured out that the depth of cure is dependent upon the light permeability of the filler, as well as the monomer composition and type and concentration of initiator, inhibitor and accelerator in the resin materials. Also Yoon et al. [27] mentioned that the degree to which materials cure is proportional to the amount of light to which they are exposed. At the upper surface of a restoration, where no overlaying composite interfaces with light transmission, it has been found that even a curing source with relatively low intensity can cure the resin matrix to an extent almost equal to that when high intensity light was used. For the Supreme composite resin we found out that the top surface values show better Vickers hardness values than the other composites used in this study. These data proved that not only the light source used but also the particular size and composition of the material affects the polymerization of the composite resin even at the nearest parts to the light source tip. Conclusion The second generation Led technology shows significantly better depth of cure from QTH lights without some drawbacks like heat transmission and limited effective lifetime. The maximum thickness for composite resins must be 2 mm even when curing with high intensity light sources. The composite resin filler type and composition may cause low polymerization efficiency due to limited light passing through the bottom surface. 44

References 1. Miyazaki M, Hattori T, Ichiishi Y, Kando M, Onose H, Moore B. Evaluation of curing units used in private dental offices. Operative Dentistry 1998; 23: 50-54. 2. Civelek A, Özel E. Iºikla polymerize olan kompozitlerin polimerizasyon derinligi. Akademik Dental 2004 Aralik; 23: 34-39. 3. Price RB, Felix CA, Andreou P. Knoop hardness of ten resin composites irradiated with high-power LED and quartz-tungsten-halogen lights. Biomaterials 2005; May 26(15): 2631-2641. 4. Soderholm KJ. Chemistry of synthetic resins. In: Anusavice KJ. editor Phillips science of dental materials.10th ed Philadelphia, W B Sounders Co, 1996; p. 216. 5. Council of Dental Materials.Visible light-cured and activating units. J. Am. Dent. Assoc 1985; 110: 100-103. 6. Althoff O, Hertung M. Advantages in light curing. AM J. Dent. 2000; 13: 77-81. 7. Nomoto R. Effect of light wavelength on polymerization of light cured resins. Dent. Mater. J 1997; 16: 60-73. 8. Millis RW, Jandt KD, Ashworth SH. Dental composite depth of cure with halogen and blue light emitting diode technology. Br. Dent J. 1999; 186: 388-391. 9. Jandt KD, Millis RW, Blackwell GB, Ashworth SH. Depth of cure and compressive strength of dental composites cured with blue light emitting diodes (LEDs). Dental Materials 2000; 16: 41-47. 10. Rueggeberg FA, Twiggs SW, Caughman WF, Khajotia S. Lifetime intensity profiles of 11 light-curing units. J. Dent. Res. 1996; 75: 380. Abstract No. 2897. 11. Barghi N, Berry T, Hatton C. Evaluating intensity output of curing lights in private dental offices. J.Am.Dent.Assoc. 1994; 125: 992-996. 12. Millis RW. Blue light emitting diodes an alternative method of light curing? Br.Dent. J. 1995; 178: 169. 13. Leonard DL, Charlton DG, Roberts HW, Cohen ME. Polymerization efficiency of LED curing lights. J Esthet Restor Dent. 2002; 14(5): 286-95. 14. Davidson Cl, de Gee AJ. Light-curing units, polymerization, and clinical implications. J. Adhes Dent 2000; 2(3): 167-173. 15. Craford MG, Holonyal N Jr, Kish FA Jr. In pursuit of the ultimate lamp. Scientific American 2001; 284(2): 63-67. 16. Dunn WJ, Bush AC. A comparison of polymerization by light-emitting diode and halogen-based light-curing units. Journal of the American Dental Association, 2002; 133(3): 335-341. 17. Soh MS, Yap AUJ, Siow KS. Effectiveness of composite cure associated with different curing modes of led lights. Operative Dentistry 2003; 28(4): 371-377. 18. Price BTR, Felix CA, Andreou P. Evaluation of a second-generation led curing light. Journal of Canadian Dental Association 2003; 69(10): 666-675. 19. Tsai PC, Meyers IA, Walsh LJ. Depth of cure and surface microhardness of composite resin cured with blue LED curing lights. Dental Materials 2004 May; 20(4): 364-369. 20. Goodis HE, White JM, Gamm B, Watanabe LG. Pulp chamber temperature changes with visible-lightcured composites in vitro. Dental Materials 1990; 6(2): 99-102. 21. Hannig M, Bott B. In vitro pulp chamber temperature rise during composite resin polymerization with various light-curing sources. Dental Materials 1999; 15(4): 275-281. 22. Shortall AC, Harrington E. Effect of light intensity on polymerization of three composite resins. European Journal of Prosthodontic and Restorative Dentistry 1996; 4(2): 71-76. 23. Loney RW, Price RBT. Temperature transmission of high-output Light-Curing units through dentin. Operative Dentistry 2001; 26: 516-520. 24. Spagnuolo G, Annunziata M, Rengo S. Cytotoxicity and oxidative stress caused by dental adhesive systems cured with halogen and LED lights. Clin Oral Investig. 2004 Jun; 8(2): 81-85. Epub 2003 Dec 16. 25. Hofmann N, Hugo B, Klaiber B. Effect of irradiation type (LED or QTH) on photo-activated composite shrinkage strain kinetics, temperature rise, and hardness. Eur J Oral Sci. 2002 Dec; 110(6): 471-479. 26. Kurachi C, Tuboy AM, Magalhaes DV, Bagnato VS. Hardness Evaluation of a dental composite polymerized with experimental LED-based devices. Dental Materials 2001; 17: 309-315. 27. Yoon TH, Lee YK, Lim BS, Kim CW. Degree of Polymerization of resin composites by different light sources. Journal of Oral Rehabilitation 2002; 29: 1165-1173. 28. Nomoto R, Mccabe JF, Hirano S. Effect of aperture size on irradiance of LED curing units. Correspondence to: Dr. Ozcan Çakmakçioglu, Department of Operative Dentistry, Faculty of Dentistry, Marmara University, Istanbul. Büyük çiftlik sok. Nisantasi, 34365 Istanbul, Turkey. E-mail: ozcancak@hotmail.com 45