Where there s flow, there s life. Measuring flow and pressure together, for even greater control

Similar documents
Where there s flow, there s life

Cytoreductive Surgery and Hyperthermic Intraperitoneal Chemotherapy

Cardiac Output Monitoring - 6

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE

Useful Ectopics: Case Study. Effects of vasodilation and the diagnostic value of ectopic heartbeats

Reducing Variation in Perioperative Fluid Utilization Results in Improved Surgical Outcomes

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the PreSep oximetry catheter for

One monitor for the whole patient pathway

Impedance Cardiography (ICG) Method, Technology and Validity

Edwards FloTrac Sensor & Performance Assessments of the FloTrac Sensor and Vigileo Monitor

CARDIAC OUTPUT Monitoring ANDY CAMPBELL JOURNAL CLUB NOV 2011

Five algorithms that calculate cardiac output from the arterial waveform: a comparison with Doppler ultrasound

Definition- study of blood flow Haemodynamic monitoring refers to monitoring of blood in the cardiovascular system Uses Is NB in the critically ill

Goal-directed vs Flow-guidedresponsive

Cogent 2-in-1 Hemodynamic Monitoring System

PulsioFlex Patient focused flexibility

WHICH CARDIAC OUTPUT MONITOR IN COLORECTAL ENHANCED RECOVERY? :

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE. Evaluation Pathway Programme assessment

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the Edwards PreSep oximetry catheter

Minimally invasive cardiac output monitors

Making the Case For Less Invasive Flow Based Parameters: APCO + SVV. Patricia A. Meehan, RN, MS, CCRN (a) Education Consultant Edwards Lifesciences

ESTIMATION OF STROKE VOLUME BY NON-INVASIVE BLOOD PRESSURE MONITORING IN HUMAN CENTRIFUGE

Impedance Cardiography (ICG) Application of ICG in Intensive Care and Emergency

Sepsis Wave II Webinar Series. Sepsis Reassessment

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the PreSep oximetry catheter for

GE Healthcare. LOGIQ Book XP. Innovation in compact ultrasound

SONIMAGE HS1. Premium Portable Ultrasound

Obligatory joke. The case for why it matters. Sepsis: More is more. Goal-Directed Fluid Resuscitation 6/1/2013

Minimally invasive cardiac output monitors

haemodynamic monitoring

PCV and PAOP Old habits die hard!

Flowchart for ICD patients undergoing Surgery or procedures involving diathermy/magnetic fields

Prof. Dr. Iman Riad Mohamed Abdel Aal

Pre-operative usage of IABP for patients for by pass surgery

Cardiac Output Monitoring: Expense justified by outcome?

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the PreSep oximetry catheter for

One hemodynamic monitor for the entire patient pathway

Admission of patient CVICU and hemodynamic monitoring

FloTrac Sensor and Edwards PreSep Central Venous Oximetry Catheter Case Presentations

SENSATION and CS300 Smaller meets faster. IABP System

Brachial Plexus Block

Peripheral Nerve Block Solutions

Confident and Conclusive Diagnosis with Flexible Solutions

Shock, Monitoring Invasive Vs. Non Invasive

Less Invasive, Continuous Hemodynamic Monitoring During Minimally Invasive Coronary Surgery

Impedance Cardiography (ICG) Application of ICG for Hypertension Management

ADVANCED PATIENT MONITORING DURING ANAESTHESIA: PART ONE

Tailored Volume Resuscitation in the Critically Ill is Achievable. Objectives. Clinical Case 2/16/2018

ACUSON P500. Ultrasound Anytime, Anywhere. ACUSON P500. siemens.com/acusonp500. siemens.com/acusonp500 1

ACUSON Sequoia C512 Echocardiography System The ultimate in imaging

SAMSUNG. Mobile excellence. Excellence on the Move ULTRASOUND H60. Ultrasound system HM70A with Plus

FLUID RESUSCITATION AND MONITORING IN SEPSIS PROTOCOLIZED VS USUAL CARE DEEPA BANGALORE GOTUR MD, FCCP ASSISTANT PROFESSOR, WEILL CORNELL MEDICAL

Continuous monitoring of cardiac output: why and how

Your Brachial Plexus Block

Hemodynamic Monitoring and Circulatory Assist Devices

Perioperative Goal- Protocol Summary

Perioperative Goal- Protocol Summary

Assessing Preload Responsiveness Using Arterial Pressure Based Technologies. Patricia A. Meehan, RN, MS Education Consultant Edwards Lifesciences, LLC

Top Performance in Action. Never confuse movement with action Ernest Hemingway

Section 6 Intra Aortic Balloon Pump

Relax and Learn At the Farm 2012

Delivering Top Performance. Outstanding Value. Exceptional Reliability. ACUSON X150 Ultrasound System. Answers for life.

A GUIDE TO OUR NIBP TECHNOLOGY

WE NEED TO REDISCOVER PHYSIOLOGY!

ZONARE Ultrasound for the Emergency Department. Living Technology

FOR IMMEDIATE RELEASE

Fluid bolus of 20% Albumin in post-cardiac surgical patient: a prospective observational study of effect duration

Early Goal-Directed Therapy

Blood Flow Measurement Devices Market - Global Industry Analysis, Size, Share, Growth, Trends and Forecast, Single User License: US $ 4595

SLEEP IMPROVING WRISTBAND. Item No Owner s Guide

An algorithmic approach to the very high risk surgical patient

Full Disclosure. The case for why it matters. Goal-directed Fluid Resuscitation

MultiStim SWITCH and MultiStim SENSOR Setting the trend in nerve stimulation

JAMES R. KNIGHT

Posted: 11/27/2011 on Medscape; Published Br J Anaesth. 2011;107(2): Oxford University Press

Hemodynamic Monitoring Pressure or Volumes? Antonio Pesenti University of Milan Italy

Division of Perioperative and Emergency Medicine, University Medical Center Utrecht, the Netherlands

GE Healthcare. Vivid i Cardiovascular ultrasound system

Permanent City Research Online URL:

Versatile, affordable ultrasound. Philips HD6 ultrasound system. The print quality of this copy is not an accurate representation of the original.

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Peri-operative management of pacemakers and implantable cardiac defibrillators

A new class of compact ultrasound. Philips CX50 CompactXtreme ultrasound system

Premium performance compact ultrasound. Philips CX50 CompactXtreme ultrasound system

Vivid T8 Ultrasound. Cardiac and shared services. Together like never before from GE.

505 Recovery rates and training (Pulse Oximeter)

powerful versatile mobile

High performance ultrasound

Cardiac, Vascular and Transplant Surgery Quality Assessment. Intraoperative Ultrasound Imaging and TTFM

Perioperative monitoring of cardiac

ACUSON P500. Ultrasound Anytime, Anywhere. ACUSON P500. siemens.com/acusonp500. siemens.com/acusonp500 1

GE Healthcare. Total-access ultrasound LOGIQ e compact ultrasound system for general imaging and shared services.

Vivid T8 Ultrasound. Cardiac and shared services. Together like never before from GE. Take rugged reliability to challenging conditions.

Ultrasound-enhanced, catheter-directed thrombolysis for pulmonary embolism

Biomedical Instrumentation E. Blood Pressure

EVOLUCIÓN DE LA MONITORIZACIÓN CARDIOVASCULAR EN LA UCI

Assessment of cardiovascular changes during laparoscopic hernia repair using oesophageal Doppler

Rounds in the ICU. Eran Segal, MD Director General ICU Sheba Medical Center

How can the PiCCO improve protocolized care?

VTE Prophylaxis. Providing venous thromboembolism (VTE) prophylaxis to all at risk hospital patients

Transcription:

Where there s flow, there s life Measuring flow and pressure together, for even greater control

Introducing the CardioQ-ODM+ The CardioQ-ODM+ is the world s first fluid management and cardiac output monitoring system to measure both flow and pressure directly. An exciting new upgrade to the proven Doppler technology, the monitor combines Doppler measurement of blood flow with Pulse Pressure Waveform Analysis (PPWA). This provides users with a proven highly sensitive Flow Monitoring Mode to guide intervention, and the simplest calibration of a Pressure Monitoring Mode for extended continuous monitoring yet devised. Previous cardiac output monitors have either been ideal intervention devices, fast precise responsive flow based measurement but non-continuous, or less responsive pressure based continuous monitors requiring complex calibration and frequent recalibration to be effective. In bringing together simple, minimally invasive oesophageal Doppler monitoring (ODM) flow based technology with a PPWA system, the CardioQ-ODM+ provides an unparalleled range of functional haemodynamic parameters. Patients can be continuously monitored for extended periods between intervention and calibration episodes. Designed for intensive care and high risk surgical applications, Deltex Medical has chosen the most stable and extensively researched PPWA algorithm currently available 1-2. Flow Monitoring Mode to guide SVO The CardioQ-ODM+ has the precision and responsiveness to guide the clinically proven >10% change Stroke Volume Optimisation (SVO). The device has established an incomparable evidence base that is today acknowledged and endorsed by the National Institute for Health and Clinical Excellence (NICE MTG3) 3. The clinical benefits of the CardioQ-ODM+ stem directly from the use of a low-frequency ultrasound signal to measure blood flow directly in the central circulation. The evidence in support of Intra Operative Fluid Management (IOFM) is centred on the implementation of oesophageal Doppler monitoring (ODM), using the Doppler mode of the CardioQ-ODM+. No other haemodynamic monitor provides the benefits of both the clinically proven Doppler based intervention mode and a stable, easily calibrated continuous monitoring system. CardioQ-ODM+ provides: Flow Monitoring Mode utilising oesophageal Doppler to guide intervention using a 10% Stroke Volume Optimisation (SVO) protocol Quick, easy calibration of PPWA algorithm at no additional cost Pressure Monitoring Mode using arterial access for extended continuous monitoring by PPWA CardioQ-ODM+ is ideal for: Intensive care High risk surgical patients transferring to overnight surgical recovery units, or ICU for postoperative monitoring Surgical cases where displacement of the oesophagus may interrupt Doppler measurement Prolonged periods of diathermy No other cardiac output device has the same precision.

a world first Easiest calibration of PPWA The CardioQ-ODM+ uses the proven Doppler technology to control both its Flow Monitoring Mode of use and the calibration of the chosen PPWA algorithm for its Pressure Monitoring Mode of cardiac output. Uncalibrated PPWA algorithms have been shown to be prone to drift due to changes in vascular tone, arterial compliance and the consequent arterial blood pressure variation. These changes have been reported to be clinically significant. Leaders in the field of PPWA technology have also strongly recommended calibration before major clinical decisions are taken 4. Recalibration may therefore be even more important than initial calibration. The inability to recalibrate easily before intervention has resulted in limitations in the use and precision of PPWA. The CardioQ-ODM+ solves the PPWA calibration problem at the highest level of precision in a matter of seconds. Simply focus the Doppler signal and calibrate the PPWA algorithm at the touch of a button. Studies of PPWA devices recommend that in critically ill patients the device should be recalibrated at least every four hours 7 and that recalibration should be performed before major clinical decisions are made 4-6. Pressure Monitoring Mode for PPWA The CardioQ-ODM+ achieves its Pressure Monitoring Mode through the use of the most stable and extensively researched PPWA algorithm currently available 1-2. Deltex Medical has chosen the algorithm proposed by Liljestrand & Zander 1. Trials of this algorithm have been reported in the literature. Deltex Medical has also performed its own extensive evaluations of its performance in a wide range of clinical situations. The Liljestrand & Zander algorithm has been shown to be superior to eight other investigational algorithms and MAP as a quantitative estimator of CO 2,7. Even so all PPWA algorithms have limitations particularly in periods of haemodynamic instability. The CardioQ-ODM+ allows the user to switch between modes of use. Clinicians can use the proven flow-based Doppler technology to guide intervention, to calibrate the PPWA algorithm for continuous monitoring in periods of stability or when it is anticipated that Doppler flow measurement may be temporarily unavailable (e.g. fully conscious patients not tolerating awake Doppler probes (I 2n), oesophagectomy, periods of diathermy). The CardioQ-ODM+ follows this clinical advice but now provides the capability to recalibrate at any moment using a quick, easy, minimally invasive and clinically proven method at no additional cost. Transmit crystal The Enhanced Recovery Partnership fully supports the use of intraoperatve fluid management technology to deliver individualised goaldirected fluid therapy. This is recommended in the 2012-13 NHS Operating Framework, in the Innovation, Health and Wealth Review, and in NICE Guideline MTG3. (Fulfilling the Potential: A Better Journey for Patients and a Better Deal for the NHS (2012), NHS Enhanced Recovery Partnership) CardioQ-ODM+ provides the simplest calibration system for a PPWA algorithm at no additional cost. Receive crystal

Set up A Setting up the CardioQ-ODM+ is a simple process. The CardioQ-ODM+ uses the same set up process as used in all Deltex Medical oesophageal Doppler monitors. The only addition is the connection of an arterial blood pressure line signal from the patient monitoring system. CardioQ-ODM+ Monitor B Patient Monitor C Disposable Pressure Transducer Catheter FIGURE 1 A An oesophageal Doppler probe is inserted into the patient s oesophagus, either nasally or orally. B The transmit and receive piezo electric crystals at the tip of the probe measure velocity of blood flow in the descending aorta. C Peripheral artery catheter for continuous measurement of arterial blood pressure.

a world first A B FIGURE 2 A Flow Monitoring Mode screen as it appears on the CardioQ-ODM+. Users can select their preferred parameters to guide intervention during fluid management. Calibration of Pressure Monitoring Mode (PPWA) is also effected from this screen. B Pressure Monitoring Mode and trend display as it appears on CardioQ-ODM+. Once calibrated users can select their preferred pressure based parameters to trend continuous monitoring or use it to provide estimated readings for short periods when Doppler is temporarily unavailable. The CardioQ-ODM+ provides all the standard Doppler parameters: Cardiac Output (CO), Cardiac Index (CI) Stroke Volume (SV), Stroke Volume Index (SVI), Stroke Distance (SD) Stroke Volume Variation (SVV), Stroke Distance Variation (SDV) Flow Time corrected (FTc), Flow Time to peak (FTp) Peak Velocity (PV), Peak Velocity Variation (PVV) Mean Acceleration (MA), Minute Distance (MD) Systemic Vascular Resistance (SVR), Systemic Vascular Resistance Index (SVRI) Delivered Oxygen (DO 2 ), Delivered Oxygen Index (DO 2 I) Heart Rate (HR) The CardioQ-ODM and the CardioQ-ODM+ together with Deltex Medical s full range of single patient disposable ultrasound probes can be purchased from NHS Supply Chain at www.supplychain.nhs.uk. CardioQ-ODM+ provides pressure-based parameters: Cardiac Output (CO), Cardiac Index (CI) Stroke Volume (SV), Stroke Volume Index (SVI) Pulse Pressure Variation (PPV) or Stroke Volume Variation (SVV) (only one can be selected at any one time), Systolic Pressure Variation (SPV) Systemic Vascular Resistance (SVR), Systemic Vascular Resistance Index (SVRI) Mean Arterial Pressure (MAP) and Blood Pressure (BP) Heart Rate (HR) CardioQ-ODM+ flow and pressure combined parameters: Cardiac Power Output (CPO) and Cardiac Power Index (CPI) (German-Austrian guidelines have indicated CPO and CPI to be important parameters in the diagnosis, monitoring and treatment of cardiogenic shock 8 ).

References 1. Liljestrand, G. & Zander, E. Vergleichen die bestimmungen des minutenvolumens des herzens beim menschen mittels der stichoxydulmethode und durch blutdruckmessung. Ztschr ges exper med 1928; (59):105 122 2. Sun, J.X. Cardiac Output Estimation using Arterial Blood Pressure Waveforms. Thesis for Master of Engineering in Electrical Engineering and Computer Science. Massachusetts Institute of Technology Sept. 2006. 3. NICE medical technology guidance 3, CardioQ-ODM oesophageal Doppler monitor March 30, 2011 http://guidance.nice.org.uk/mtg3 4. Linton, N.W.F. & Linton, R.A.F. Estimation of changes in cardiac output from the arterial blood pressure waveform in the upper limb. British Journal of Anaesthesia 2001; 86 (4): pp 486-496. 5. Cecconi, M., et al. Lithium dilution cardiac output measurement in the critically ill patient: determination of precision of the technique. Intensive Care Med. 2009; 35 (3): pp 498-504. 6. Cecconi, M., et al. A prospective study to evaluate the accuracy of pulse power analysis to monitor cardiac output in critically ill patients. BMC Anesthesiology 2008, 8:3 http://www.biomedcentral.com/1471-2253/8/3 7. Sun, J.X., et al. The cardiac output from blood pressure algorithms trial. Crit Care Med 2009; 37(1): pp 72-80. 8. Dtsch Arztebl Int. 2012 May; 109(19): 343 351. (Published online 2012 May 11). http://www.ncbi.nlm.nih.gov/pubmed/22675405 Product Description CardioQ-ODM+ Monitor (Product Code: 9051-7104) For adult use in operating theatre and critical care. Managed care service and rental option available upon request. Surgical Probes DP6 Doppler Probe (Product Code: 9070-7001) 6-hour oral/nasal Doppler probe for patients under anaesthesia or full sedation. DP12 Doppler Probe (Product Code: 9070-7003) 12-hour oral/nasal Doppler probe for patients under anaesthesia or full sedation. I 2 S Doppler Probe (Product Code: 9090-7012) 6-hour oral/nasal Doppler probe for anaesthetised, sedated and awake patients. I 2 P Doppler Probe (Product Code: 9090-7013) 24-hour oral/nasal Doppler probe for anaesthetised, sedated and awake patients. Critical Care Probes I 2 C Doppler Probe (Product Code: 9090-7014) 72-hour oral/nasal Doppler probe for anaesthetised, sedated and awake patients. DP240 Doppler Probe (Product Code: 9070-7005) 10-day oral/nasal Doppler probe for patients under anaesthesia or full sedation. When fluid management really matters, think Doppler Deltex Medical Terminus Road, Chichester, West Sussex PO19 8TX To order please contact: Customer Service: 0845 085 001 Email: uksales@deltexmedical.com For enquires please contact: General Enquiries: +44(0) 1243 774 837 Fax: +44(0)1243 532 534 www.deltexmedical.com AKA 9051-5560 Issue 2 CO1008