CERTIFICATE OF ACCREDITATION

Similar documents
CERTIFICATE OF ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Specializing in Mechanical Testing for Medical Devices. Office:

ISO INTERNATIONAL STANDARD. Dentistry Implants Dynamic fatigue test for endosseous dental implants

YY Translated English of Chinese Standard: YY

Operations included in the National Joint Registry (NJR) Quick links, go to: Hips > Knees > Ankles > Elbows > Shoulders > Trauma >

Cannulated Screw System. Product Overview

Operations included in the National Joint Registry (NJR)

DRAFT GUIDANCE DOCUMENT List of Recognized Standards

This document is a preview generated by EVS

IDENTIFICATION OF THE PARAMETERS THAT INFLUENCE THE UNCERTAINTY SOURCES IN ORTOPHAEDIC IMPLANTS FATIGUE TESTS

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

Beijing, China, East, Dongcheng District, North Third Ring Road. Beijing Global Trade Center #36

CERTIFICATE OF ACCREDITATION

Implants for surgery Partial and total hip joint prostheses. Part 12: Deformation test method for acetabular shells

Section of total knee replacement. Total Knee Replacement System. Knieendoprothesen System. Système de prothèse totale de genou

CONSENSUS ORTHOPEDICS INC. UNISYN HIP SYSTEM

(c) B. Ravi, IIT Bombay 1

July 10, X-spine Systems, Incorporated David Kirschman, MD Chief Medical Officer 452 Alexandersville Road Miamisburg, Ohio 45342

Hard Implants. Lecture #13

The University of Sydney Slide 1

Biomechanical Analysis of Hip Joint Arthroplasties using CT-Image Based Finite Element Method

Lumbar Dynamic. Reinhold Knebel Product Manager

The Most Reliable Spinal Solution

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

ISO INTERNATIONAL STANDARD

Bone Bangalore

Ceramic Femoral Heads and Acetabular Cup Liners

CAUTION Federal law (USA) restricts this device to sale, by or on the order of a physician.

Research experimental of hipbone arthroplasties using tensometric models

RECLAIM REVISION HIP SYSTEM

DENTAL DYNAMIC ABUTMENT AND IMPLANT SYSTEM. RESULTS OF FATIGUE RESISTANCE TO COMPRESSION BENDING. On request of: TALLADIUM ESPAÑA

Osteoarthrosis, unspecified whether generalized or localized, lower leg. Osteoarthrosis, localized, not specified whether primary or secondary, pelvic

QUICK REFERENCE GUIDE. Arthrodesis. Joint Fusion. By Dr. S. Agostini and Dr. F. Lavini

Knee Revision. Portfolio

Table of Contents.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CERTIFICATE OF ACCREDITATION

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

ISO INTERNATIONAL STANDARD. Non-active surgical implants Joint replacement implants Particular requirements

QUICK REFERENCE GUIDE. Arthrodiatasis. Articulated Joint Distraction

NOVEMBER On request of: Medical Precision Implants, S.A.

HOSPITAL "A" (2007) ORTHOPEDIC JOINT IMPLANT COMPONENT MATRIX

ASTM Committee F04 Tuesday 05/19/2015 Grand Ballroom F Platinum 9

Fracture fixation. Types. Mechanical considerations. Biomechanics of fracture fixation. External fixation. Internal fixation

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Talos -C (HA) and the PEEK-OPTIMA HA Enhanced Technology

The short stem hip system Surgical Technique

Document No Rev. B Pg. 1 of 5 Approvals / Date Title: INSTRUCTIONS FOR USE DJO SURGICAL MODULAR REVISION HIP SYSTEM AND ACETABULAR CAGE

Initial Fixation Strength of Bio-absorbable Magnesium Screw

Patel V, Venkatarayappa I, Prayson MJ, Goswami T. Biomechanical evaluation of hybrid locking plate constructs. Hard Tissue 2013 Jun 01;2(4):32.

A U X I L I A R Y C O N N E C T O R S Surgical Technique

Instructions for use for Adler Cemented Total Hip Replacement Prosthesis

TM TM Surgical Technique

TriboFit Hip System. Issue 3 - August 2013 English

Optimum implant geometry

TRABECULAR METAL AUGMENTS. Includes Surgical Technique Abbreviated for LCCK and RHK Trabecular Metal Augments


PARADIGM SPINE. Anterior Cervical Fusion Cage. Cervical Interbody Fusion

Optimizing function Maximizing survivorship Accelerating recovery

Revision systems. Catalogue - revision implants ARTHROPLASTY

Duraloc CONSTRAINED LINER

Merete BioBall The Innovative Hip Endoprosthesis Head Adapter System

TOTAL KNEE ARTHROPLASTY (TKA)

CARPAL ANATOMY. 2 carpal rows:

Hip Joint Prostheses

Innovation in Medical Technology. BIOTECH GroupG

ORION Screw System PRODUCT INFORMATION

HIP CONTINUUM OF CARE. Trauma and Joint Reconstruction Hip Portfolio

Wear Properties of UHMWPE in CHARITE Artificial Inter-vertebral Disc

EFSPINE CERVICAL COMBINED SET DISC PROTHESIS ORGANIZER BOX

Instructions for use for ADLER Cemented Bipolar hemi-arthroplasty Prosthesis

SVENSK STANDARD SS-EN ISO 14801:2004. Tandvård Utmattningstest för benförankrade dentala implantat (ISO 14801:2003)

UniSyn Hip System. Instrument Catalog

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Furlong H-A.C. THR System

Zimmer Segmental System

Pelvis injuries Fractures of the femur (proximal,shaft) Dr Tamás Bodzay

Bone Preservation Stem

Clinical Biomechanics in Spinal Surgery

Optimum implant geometry

operative technique Kent Hip

Biomechanics of Interspinous Process Fixation and Lateral Modular Plate Fixation to Support Lateral Lumbar Interbody Fusion (LLIF)

FATIGUE DEVICE FOR TESTING ANKLE JOINT ENDOPROSTHESES

For the Attention of the Operating Surgeon: IMPORTANT INFORMATION ON THE MATRIXRIB FIXATION SYSTEM

Nailing Stability during Tibia Fracture Early Healing Process: A Biomechanical Study

BIOMECHANICS OF THE SPINE AND IMPLANT FIXATION

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

Index. Gainslen prosthesis 125. Debonding 22-3 Degradation products 40-1 Diffusion theory of adhesive wear 137 Dual energy X-ray absorption 95-6, 98

MetaFix Cementless Total Hip Replacement Product overview

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

comprehensive Design Rationale shoulder system Knees Hips Extremities Cement and Accessories PMI TEchnology

EC Certification. FULL QUALITY ASSURANCE SYSTEM Directive 93/42/EEC for Medical Devices, Annex II excluding (4)

ME/BioE C176 Final Exam, Fall 2001

Aesculap Trilliance Triple Tapered Polished Hip Stem

Illustrative exercises for the lectures

OPTIONAL/ADDITIONAL INSTRUMENTS

QUICK REFERENCE GUIDE. The XCaliber Meta-Diaphyseal Fixator

FRACTOGRAPHIC INVESTIGATION OF FAILURES IN 316L STAINLESS STEEL ORTHOPEDIC CONDYLAR BLADE PLATE

Transcription:

CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that JTL America 3205 Clairmont Ct., Ste. B Fort Wayne, IN 46808 has been assessed by ANAB and meets the requirements of international standard ISO/IEC 17025:2005 while demonstrating technical competence in the fields of TESTING Refer to the accompanying Scope of Accreditation for information regarding the types of calibrations and/or tests to which this accreditation applies. L2167 Certificate Number Certificate Valid: 12/16/2017-01/9/2020 Version No. 002 Issued: 12/16/2017 This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017).

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 JTL America 3205 Clairmont Ct., Ste. B Fort Wayne, IN 46808 Kevin Knight 260-489-1444 TESTING Valid to: January 9, 2020 Certificate Number: L2167 Mechanical Specific Tests and/or Properties Measured Tension & Compression Monotonic Testing Force Controlled Cyclic Testing (0 to 30) Hz Displacement Controlled Cyclic Testing (0 to 30) Hz Torsional Monotonic Testing (-225 to 225) Nm (0 to 15) Revolutions Specification, Standard, Method, or Test Technique Items, Materials or Product Tested and All Metal Alloys Key Equipment or Technology Page 1 of 4

Mechanical Specific Tests and/or Properties Measured Torque Controlled Cyclic Testing (-225 to 225) Nm (0 to 270) degrees (0 to 5) Hz Fracture Toughness Testing (Up to 5) in Axial Fatigue Testing (Strain and Stress) Note: Specification, Standard, Method, or Test Technique ASTM E399 ASTM B645 ASTM E1820 ASTM E466 ASTM E606 Items, Materials or Product Tested All Metal Alloys All Metal Alloys 1. This scope is formatted as part of a single document including Certificate of Accreditation No. L2167. 2. This laboratory offers commercial testing service. Key Equipment or Technology JTL America has demonstrated technical competency to perform ISO/IEC 17025:2005 accredited testing activities per the test technologies identified in the table above and the test methods identified below per the attached annex 1. Annex 1 ISO/IEC 17025 Accredited Test Methods ASTM Test Methods: F382 F543 F564 F1044 Coatings F1147 F1160 F1440 F1223 F1264 Standard Specification and Test Method for Metallic Bone Plates Standard Specification and Test Methods for Metallic Medical Bone Screws Standard Specification and Test Methods for Metallic Bone Staples Standard Test Method for Shear Testing of Calcium Phosphate Coatings and Metallic Standard Test Method for Tension Testing of Calcium Phosphate and Metal Coatings Standard Test Method for Shear and Bending Fatigue Testing of Calcium Phosphate and Metallic Medical and Composite Calcium Phosphate/Metallic Coatings Standard Practice for Cyclic Fatigue Testing of Metallic Stemmed Hip Arthroplasty Femoral Components without Torsion Standard Test Method for Determination of Total Knee Replacement Constraint Standard Specification and Test Methods for Intramedullary Fixation Devices Page 2 of 4

F1612 F1717 F1798 F1800 F1820 F2009 F2028 F2077 F2193 F2267 F2345 F2502 F2706 F2777 E8 E9 E466 E606 E1820 E399 B645 Alloys Standard Practice for Cyclic Fatigue Testing of Metallic Stemmed Hip Arthroplasty Femoral Components with Torsion Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model Standard Guide for Evaluating the Static and Fatigue Properties of Interconnection Mechanisms and Subassemblies Used in Spinal Arthrodesis Implants Standard Test Method for Cyclic Fatigue Testing of Metal Tibial Tray Components of Total Knee Joint Replacements Standard Test Method for Determining the Axial Disassembly Force of a Modular Acetabular Device Standard Test Method for Determining the Axial Disassembly Force of Taper Connections of Modular Prostheses Standard Test Methods for Dynamic Evaluation of Glenoid Loosening or Disassociation Test Methods for Intervertebral Body Fusion Devices Standard Specifications and Test Methods for Components Used in the Surgical Fixation of the Spinal Skeletal System Standard Test Method for Measuring Load Induced Subsidence of an Intervertebral Body Fusion Device under Static Axial Compression Standard Test Methods for Determination of Static and Cyclic Fatigue Strength of Ceramic Modular Femoral Heads Standard Specification and Test Methods for Bioabsorbable Plates and Screws for Internal Fixation Implants Standard Test Methods for Occipital-Cervical and Occipital-Cervical-Thoracic Spinal Implant Constructs in a Vertebrectomy Model Standard Test Method for Evaluating Knee Bearing (Tibial Insert) Endurance and Deformation Under High Flexion Standard Test Methods for Tension Testing of Metallic Materials Standard Test Methods of Compression Testing of Metallic Materials at Room Temperature Standard Practice for Conducting Force Controlled Constant Amplitude Axial Fatigue Tests of Metallic Materials Standard Test Method for Strain-Controlled Fatigue Testing Standard Test Method for Measurement of Fracture Toughness J Ic Standard Test Method for Linear-Elastic Plane-Strain Fracture Toughness K Ic of Metallic Materials Standard Test Method for Linear-Elastic Plane-Strain Fracture Toughness of Aluminum Page 3 of 4

ISO Test Methods: 7206-4 Implants for surgery -- Partial and total hip joint prostheses -- Part 4: Determination of endurance properties and performance of stemmed femoral components 7206-6 Implants for surgery -- Partial and total hip joint prostheses -- Part 6: Determination of endurance properties of head and neck region of stemmed femoral components 7206-10 Implants for surgery -- Partial and total hip-joint prostheses -- Part 10: Determination of resistance to static load of modular femoral heads 9585 Determination of bending strength and stiffness of bone plates 14801 Dentistry -- Implants -- Dynamic fatigue test for endosseous dental implants 6892-1 Metallic Materials -- Tensile Testing -- Part 1: Method of Test at Room Temperature Page 4 of 4