Effectiveness of ilizarov frame fixation on functional outcome in aseptic tibial gap non-union

Similar documents
ILIZAROV METHOD IN TREATMENT OF TIBIAL AND FEMORAL INFECTED NON-UNIONS IN PATEITNES WITH HIGH-ENERGY TRAUMA AND BATTLE-FIELD WOUNDS

Management of Nonunion of Tibia by Ilizarov Technique Haque MA 1, Islam SM 2, Chowdhury MR 3

Of approximately 2 million long bone fractures

Tibial deformity correction by Ilizarov method

Small-wire circular fixators and hybrid external fixation

Stress Fracture Of The Supracondylar Region Of The Femur Induced By The Weight Of The Tibial Ring Fixator

Large segmental defects of the tibia caused by highenergy. Ten Year Experience with Use of Ilizarov Bone Transport for Tibial Defects

Correction of Traumatic Ankle Valgus and Procurvatum using the Taylor Spatial Frame: A Case Report

ILIZAROV TECHNIQUE IN CORRECTING LIMBS DEFORMITIES: PRELIMINARY RESULTS

SCIENTIFIC POSTER #28 Tibia OTA 2016

Assessment of Regenerate in Limbs by Ilizarov External Fixation

Treatment of delayed union or non-union of the tibial shaft with partial fibulectomy and an Ilizarov frame

Treatment of septic non-union of tibia using compression and distraction technique with ilizarov circular fixator

Kocaoglu, Mehmet MD; Eralp, Levent MD; Sen, Cengiz MD; Cakmak, Mehmet MD; Dincyürek, Hakan MD; Göksan, S. Bora MD

Is Distraction Histiogenesis a Reliable Method to Reconstruct Segmental Bone and Acquired Leg Length Discrepancy in Tibia Fractures and Non Unions?

Accuracy of complex lower-limb deformity correction with external fixation: a comparison of the Taylor Spatial Frame with the Ilizarov Ringfixator

Management of a large post-traumatic skin and bone defect using an Ilizarov frame

Temporary Intentional Leg Shortening and Deformation to Facilitate Wound Closure Using the Ilizarov/Taylor Spatial Frame

Adult Posttraumatic Reconstruction Using a Magnetic Internal Lengthening Nail

Evaluation of the functional outcome in open tibial fractures managed with an Ilizarov fixator as a primary and definitive treatment modality

We present a series of ten hypertrophic nonunions

Fractures of the tibia shaft treated with locked intramedullary nail Retrospective clinical and radiographic assesment

Techique. Results. Discussion. Materials & Methods. Vol. 2 - Year 1 - December 2005

CASE REPORT. Bone transport utilizing the PRECICE Intramedullary Nail for an infected nonunion in the distal femur

Neurologic Damage. The most common neurologic injury following intramedullary tibial nailing is injury to the peroneal nerve.

Outcome of Treatment of Nonunion Tibial Shaft Fracture by Intramedullary Interlocking Nail augmentated with Autogenous Cancellous Bone Graft.

Bone transport for the management of severely comminuted fractures without bone loss

S-osteotomy with lengthening and then nailing compared with traditional Ilizarov method

Ilizarov ring fixator in the management of infected non-unions of tibia

Surgical treatment of aseptic nonunion in long bones: review of 193 cases

Ipsilateral Fibular Transport Using Ilizarov Taylor Spatial Frame for a Limb Salvage Reconstruction: a Case Report

Bone transport using the Ilizarov method: a review of complications in 100 consecutive cases

Segmental tibial fractures treated with unreamed interlocking nail A prospective study

CASE REPORT. Antegrade tibia lengthening with the PRECICE Limb Lengthening technology

Metatarsal Lengthening By Callus Distraction For Brachymetatarsia: Case Report and Review of the Literature

Tibial Shaft Fractures

Surgery-Ortho. Fractures of the tibia and fibula. Management. Treatment of low energy fractures. Fifth stage. Lec-6 د.

Case Report Correction of Length Discrepancy of Radius and Ulna with Distraction Osteogenesis: Three Cases

A prospective study of functional outcome of primary intra-medullary nailing in type 3A and 3B open tibial diaphyseal fractures

DISTRACTION OSTEOGENESIS IN SEGMENTAL BONE DEFECTS IN TIBIA BY MONOAXIAL EXTERNAL FIXATOR

Fixator-assisted nailing and consecutive lengthening over an intramedullary nail for the correction of tibial deformity

Circumferential skin defect - Ilizarov technique in plastic surgery

Lengthening & Deformity correction with. Fixator Assisted Nailing

Acute compression and lengthening by the Ilizarov technique for infected nonunion of the tibia with large bone defects

Deformity correction during growth after partial physeal arrest

Case Report. Antegrade Femur Lengthening with the PRECICE Limb Lengthening Technology

Comparison of acute compression distraction and segmental bone transport techniques in the treatment of tibia osteomyelitis

Metatarsal Lengthening By Callus Distraction For Brachymetatarsia. Case Report and Review of the Literature

Fibula Lengthening Using a Modified Ilizarov Method S. Robert Rozbruch, MD; Matthew DiPaola, BA; Arkady Blyakher,MD

abstract n Feature Article Chun-Cheng Lin, MD; Chuan-Mu Chen, MD; Fang-Yao Chiu, MD; Yu-Pin Su, MD; Chien-Lin Liu, MD; Tain-Hsiung Chen, MD

Management of massive posttraumatic bone defects in the lower limb with the Ilizarov technique

Vasu Pai FRACS, MCh, MS, Nat Board Ortho Surgeon Gisborne

The space shuttle docking at the international space station

management of sports injuries

KEYWORDS: Tibial fracture, Diaphyseal fracture, closed interlocking intramedullary nailing,

Computer Assisted Deformity Correction Using the Ilizarov Method

Management of Complex Non Union in Long Bones with Limb Reconstruction System (Rail Fixator) Application

The ipsilateral and contralateral fibulae have been

Supramalleolar Osteotomy Using Circular External Fixation with Six-Axis Deformity Correction of the Distal Tibia

2017 Resident Advanced Trauma Techniques Course COMPLICATIONS / CHALLENGES MALUNIONS/DEFORMITY

Prophylactic surgical correction of Crawford s type II anterolateral bowing of the tibia using Ilizarov s method

Treatment of Open Fractures of Tibia by Ilizarov Technique

Pediatric Tibia Fractures Key Points. Christopher Iobst, MD

Guidance for the Physiotherapy Management of Patients Undergoing Limb Reconstruction with a Circular Frame External Fixator.

OUTCOME OF MANAGEMENT OF CLOSED PROXIMAL TIBIA FRACTURES IN TERTIARY HOSPITAL OF SURAT Karan Mehta 1, Prashanth G 2, Shiblee Siddiqui 3

The Effect of Bone Marrow Aspirate Concentrate (BMAC) and Platelet-Rich Plasma (PRP) during Distraction Osteogenesis of the Tibia

Factors affecting fracture healing after intramedullary nailing of the tibial diaphysis for closed and grade I open fractures

Treatment of open tibial shaft fractures using intra medullary interlocking

A comparative study of locking plate by MIPO versus closed interlocking intramedullary nail in extraarticular distal tibia fractures

TIPMED EXTERNAL FIXATION SYSTEMS

Surgical interventions in chronic osteomyelitis

EXPERT TIBIAL NAIL PROTECT

Orthopaedic Thesis Journal of Medical Thesis 2014 Sep-Dec; 2(3):26-30

Composite Bone and Soft Tissue Loss Treated With Distraction Histiogenesis

Debate: I Do Bone Transport. Disclosures. Bone Defects 5/10/2017

Combined external fixation and intramedullary alignment in correction of limb length discrepancies

Galal Zaki Said 1, *, Osama Ahmed Farouk 1, Hatem Galal Said 1

Results of Surgical Treatment of Coxa Vara in Children: Valgus Osteotomy with Angle Blade Plate Fixation

A Clinical Study For Evaluation Of Results Of Closed Interlocking Nailing Of Fractures Of The Shaft Of The Tibia

Kirienko Alexander Peccati Andrea, Portinaro Nicola Istituto Clinico Humanitas, Milano, Italy

Calculation and Correction of Secondary Translation Deformities and Secondary Length Deformities

.org. Tibia (Shinbone) Shaft Fractures. Anatomy. Types of Tibial Shaft Fractures

Fibula-related complications during bilateral tibial lengthening

Treatment of malunited fractures of the ankle

E ORIGINAL ARTICLE Low extra-articular (transcondylar) fractures of the distal humerus

Multiple Exostoses / Multiple Osteochondroma of the Lower Limb Guide By Dror Paley M.D.,

Tibiocalcaneal fusion using a peg-in-hole technique combined with Ilizarov external fixation method

Morbidity resulting from the treatment of tibial nonunion with the Ilizarov frame

Congenital Pseudarthrosis of the Tibia with Complex Deformity and Multiple Previous Surgeries Treated by Taylor Spatial Frame at Age of 16 Years

Tibial Nonunions: Should I Tackle and How

Simultaneous joint fusion and limb lengthening for knee deformities in children: a one-stage procedure The Kampala experience

7/23/2018 DESCRIBING THE FRACTURE. Pattern Open vs closed Location BASIC PRINCIPLES OF FRACTURE MANAGEMENT. Anjan R. Shah MD July 21, 2018.

The tibial bayonet method of wound closure

Pilon Fractures Pearls of Treatment Steven Steinlauf, MD The Orthopaedic Foot and Ankle Institute of South Florida CSOT November 2017, Tampa

Fibula bone grafting in infected gap non union: A prospective case series

Original Research Article

Ilizarov treatment for aseptic delayed union or non-union after reamed intramedullary nailing of the femur

The Use of Ilizarov External Fixation Following Failed Internal Fixation

Functional outcome of management of infected nonunion of humerus by limb reconstruction system (LRS)

The Surgical Management of Rickets & Osteogenesis Imperfecta

Transcription:

29th Pak Orthocon 2015 S-179 ORIGINAL ARTICLE Effectiveness of ilizarov frame fixation on functional outcome in aseptic tibial gap non-union Rana Dawood Ahmad Khan, Muhammad Asif Maqbool, Ajmal Yasin Abstract Objectives: The Objective of the study is to evaluate the effect of Ilizarov frame fixation on functional outcome in aseptic tibial gap non-union cases Methods: In this clinical study, 15 cases of post-traumatic aseptic tibial gap non-union were selected in department of orthopedics, Allied Hospital Faisalabad, Punjab Pakistan, during years 2013-2014. After blood analysis and clinical assessment, the aseptic gap nonunion cases underwent ilizarov frame fixation for their problem. They were taught about care of ilizarov fixator and pin tract. They were called on regular basis and pre and post-surgery functional outcome was measured by modified functional evaluation system by Karlstrom-Olerud. Results: Out of the 15 patients, 12 (80%) with road traffic accident, 2 (13.3 %) with gunshot injury and 1(6.66%) with fall from height; 9(60%) were treated by compression technique (fig.1,2,7,8,11), 4(2.66%) with compressiondistraction (fig.3,10) and 2 (13.3 %) were treated using distraction-compression technique (bone transport) (fig.4,5,6). Mean gap was 6.33cm (range 2-12cm). Duration of tibial gap union was average 10.60 months (minimum 8 months, maximum 15 months) and union was achieved in all the cases in mean time of 25.20 weeks (minimum 13 weeks, maximum 57 weeks). Patients remained in ilizarov fixator frame for average 6.80 months (range minimum 4, maximum 13 months). Pin tract infection and pain were common Complications. The functional outcome was measured by modified functional evaluation system by Karlstrom-Olerud 5 showed good, 4 satisfactory, 4 moderate and 2 poor results. Conclusion: The Ilizarov technique is an effective method in treating the aseptic tibial gap non-union. Patient's motivation and co-operation played an important role in good to excellent outcomes. Keywords: Aseptic, Functional, Ilizarov, Gap Nonunion, Tibial. (JPMA 65: S-179 (Suppl. 3); 2015) Introduction Tibial gap nonunions have been treated with a variety of surgical methods including plate osteosynthesis with bone graft, 1-3 intramedullary nailing, 4-7 and external fixation. 8-10 The complexity of a tibial gap nonunion can be variable and depends on several factors. The ''personality of a fracture'' is a term and concept introduced by Schatzker 11 and its use underscores the complexity of a particular problem and helps organize a treatment approach. We have found it helpful to apply this concept to gap nonunion. The personality of a tibial gap nonunion is determined by a number of factors including bone loss; radiographic appearance and stiffness as they relate to the nonunion biology; deformity; leg-length discrepancy (LLD); presence or history of infection; soft-tissue envelope; retained hardware; and patient factors including diabetes, smoking, and neuropathy. Although the use of internal fixation is effective in the treatment of selected tibial gap nonunions, Department of Orthopedic Surgery, Allied Hospital, Punjab Medical College, Faisalabad. Correspondence: Muhammad Asif Maqbool. Email: dr.m.asif.maqbool@gmail.com these techniques have their limitations. The Ilizarov method has gained many advocates for the treatment of tibial gap nonunions over the last 2 decades, particularly hypertrophic gap nonunions, 12 and gap nonunions associated with bone loss, 13-16 infection 17,18 and a poor soft-tissue envelope. 13, 19 The classic Ilizarov frame has been used to correct all deformity, 20-23 including lengthening and bone transport. 13,15,19 However, deformity correction with components of angulation, translation, and rotation requires a staged correction and frame modifications. 24 The purpose of this study was to review the results of our experience with a consecutive series of complex tibial gap nonunion defects. Materials and Methods This prospective study was conducted in the Department of Orthopedic Surgery at Allied Hospital, Faisalabad, Punjab, Pakistan. The patients were selected and treated between years of 2013 to 2014. Patients having aseptic tibial gap nonunion with no signs of clinical, radiological and biomechanical evidence of infection were included in the study. Patients with history of other injuries, those aged above 50 or under 14,(SD 34.93±10.87) and those suffering from rheumatoid arthritis, diabetic mellitus, and fracture in the other limb were all excluded from the

S-180 29th Pak Orthocon 2015 study. After fulfilling the inclusion and exclusion criteria, 15 Patients, aged between 14 and 50 were enrolled as study subjects based on clinical findings along with erythrocyte sedimentation rate, C-reactive protein levels and tissue culture reports. The patient's pre-operative X- rays and functional assessment were done using modified functional evaluation system by Karlstrom-Olerud. 25,26 Final scoring system for Modified Functional Evaluation System by Karlstrom-Olerud Excellent Good Satisfactory Moderate 33 Points 32-30 Points 29-27 Points 26-24 Points Poor 23-21 Points After anesthesia patients underwent standard method of Ilizarov frame application. After a latent period of 10-14 days, the lengthening was started. 1) Compression technique was used when there is hypertrophic gap nonunion with no shortening or shortening less than four centimeters. The compression of the fracture was done by moving the rings together and compressing the fracture site and maintaining the ring until radiological evidence of union is seen. 2) Compression and distraction technique was used when the hypertrophic gap nonunion showed bone shortening of more than four centimeters. In this method, we have compressed the both ends of the fracture for 10-14 days and then distracted the compressed site slowly at the rate of 0.25 mm every six hours or 1 mm per day. 3) Distraction-compression is used in cases of oligotrophic or atrophic gap nonunion with bone shortening of more than four centimeters. In this method, the patient will be kept on a circular frame and corticotomy is usually done in the metaphysis to ensure good regeneration. The aim is to mobilize the middle segment, and lengthening will be done through the corticotomy site. Both ends of the fracture segment approximation are called docking. The frame would remain in this position until there is a radiological evidence of bone union. All patients were operated on by the same orthopedic surgeon using the hybrid Ilizarov fixator technique. Immediately after surgery, X-rays and clinical assessment were done. Physical Therapy was started as soon as the patient was comfortable, and gentle active assistive exercises and active exercises were done for ankle and knee within the pain free ranges. Weight bearing on affected leg was progressively increased from toe touching to full foot touching in the first week. After the first week walking was initiated with partial to full weight bearing as per patient tolerance. Isometric quadriceps exercise and gentle knee mobilization were started up to the available range within the first week. In the first few days after surgery, patients were on oral analgesics. Prophylactic antibiotics (3rd generation cephalosporin) and wound care (pin tract and corticotomy site) were strictly followed to prevent any further problems. Patients were educated and properly trained on how to wash fixator and pins and were discharged from the hospital ward when they started walking with partial weight bearing and were able to go to the toilet independently They were then followed up in the outpatient department, first on a weekly basis and then twice a month. The fixators were removed by admitting the patients for day care surgery. After the removal of the fixators, patients received physical therapy and were dispensed above or below the knee braces to use for the duration of 4 weeks. The patients were allowed to walk with full weight bearing, and after 5 weeks of regular physical therapy, functional scoring with modified functional evaluation system by Karlstrom-Olerud was performed again. Results 15 patients aged between 14 and 50 participated in this Table-1: Modified Functional Evaluation System by Karlstrom-Olerud. Sr No Measurement 3 Points 2 Points 1 Point 1 Pain No Little Severe 2 Difficulty in walking No Moderate Severe Limp 3 Difficulty in stairs No Supported Unable 4 Difficulty in previous sports No Some sports Unable 5 Limitation at work No Moderate Unable 6 Status of skin Normal Various colors Ulcer/Fistula 7 Deformity No Little, up to 7o Remarkable,>7o 8 Muscle atrophy <1cm 1-2 cm >2cm 9 Shorter lower extremity <1cm 1-2 cm >2cm 10 Loss of motion at knee joint <10o 10-20o >20o 11 Loss of motion at Subtalar motion <10o 10-20o >20o J Pak Med Assoc (Suppl. 3)

29th Pak Orthocon 2015 S-181 Table-2: Sr no Characteristics 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 average SD 1 Cause of injury RTA RTA RTA RTA GS RTA RTA RTA FFH RTA RTA RTA GS RTA RTA 2 Duration of non-union in months 8 11 14 9 14 9 10 9 8 15 10 9 10 9 14 10.60 ±2.4 3 Average bone gap in cm 2 2 7 3 10 3 9 3 3 12 8 2 2 3 11 5.33 ±3.72 4 Technique used C C CD C CD C CD C C CBT CD C C C CBT 5 Duration of frame in months 4 5 6.5 5 8 5.5 8.5 5 4.5 13 8.5 5 5.5 6 12 6.80 ±2.71 6 Time of union in weeks 13 18 22 17 30 19 32 17 15 57 31 18 18 22 49 25.20 ±12.77 RTA- road traffic accident, C-compression, CD-compression-distraction, CBT-compression-bone transport. Table-3: Patient characteristics. Sr No. Characteristics Description 1 Cause of injury 12 Road traffic accident, 2 gun shoot injury, 1 fall from height, 2 Duration of non-union Minimum 8 months, maximum 15 months, average 10.60 months 3 Average bone gap Minimum 2 cm, maximum 12 cm, average 5.33 cm 4 Technique used 9 Compression, 4 compression-distraction, 2 compression+bone transport 5 Duration of frame Minimum 4 months, maximum 13 months, average 6.80 months 6 Time of union in weeks Minimum 13weeks, maximum 57, weeks, average 25.20 weeks Figure-1: Patient of RTA with gap non union of tibia, treated with ilizarov fixator, compression applied. Figure-2: Gap non union due to RTA, treated by compression by ilizarov fixator. Figure-3: Ilizarov fixator on tibia with gap non union due to RTA, compression-distraction done. study. They all suffered from an average duration of gap nonunion of 10.60 months, and the average nonunion gap was 5.33 cm and average duration in the frame was 6.80 months. Out of these 15 patients, nine were treated with compression, (bone shortening was less than 4cm that was covered by shoes) four with compression and distraction and two with distraction-compression. All the patients included in this study had a union of their gap non-united fractures even though two patients had shown poor outcome on the functional scale. The duration of time the patients remain in the frame indicates the healing time of the patients because they were kept in the ring until complete union was seen radio graphically. The minimum duration of frame on the patients was 6 months and maximum was 15 months. Out of the 15 patients, 13 patients showed moderate to good

S-182 29th Pak Orthocon 2015 Figure-4: Gap non union tibia treated by compressionbone transport by ilizarov fixator. Figure-5: Follow up picture, bone transport being done and callus visible. Figure-6: 12 weeks post OP case after ilizarov fixator, CBT done, callus visible. Figure-7: Gap non union distal third tibia due to RTA, compression provided b ilizarov fixator. Figure-8: Gap non union of Rt tibia due to RTA treated by ilizarov fixator. Figure-9: Tibial gap non union due to FAI, compression provided by ilizarov fixator. J Pak Med Assoc (Suppl. 3)

29th Pak Orthocon 2015 S-183 Figure-11: Gap non union due to FAI, treated by ilizarov fixator, compression provided. Figure-10: Gap non union right tibia due to fall from height, CD provided by ilizarov fixator. Figure-12: Percentage of results functional recovery on modified functional evaluation system by Karlstrom-Olerud. Discussion Long standing gap non-union is difficult to treat and is a challenging problem for the orthopedicians. It, usually, leads to residual deformity, persistent infection, and contracture in the affected limb. Different methods have been employed to treat this situation e.g., radical debridement, local flaps, muscle flaps, bone grafting, tibiofibular synostosis, cancellous allograft, fibrin mixed with antibiotics, micro-vascular flaps and vascularized bone transplants. 27 All have improved results, but none has been able to solve this clinical situation fully. The Ilizarov ring fixator gives an option of compression, distraction and bone transport, and is effective in the treatment of gap non-union of the tibia where other types of treatment have failed. Weight bearing and the functioning of the joints while on the treatment is an advantage that cannot be matched by any other

S-184 29th Pak Orthocon 2015 technique. 28 The Ilizarov apparatus is axially elastic and as the weight bearing forces are directly applied to the bone ends, maintaining the weight bearing function of the extremity actually becomes one of the prerequisites for the success of the method. The cyclic axial telescoping mobility, not rigidity, at the non-union or fracture site is an important requirement for the formation of a reparative callus. Ilizarov experimentally showed that when gradual distraction tension stress is applied to the corticotomy site, the vascularity of the entire limb is increased, which in turn enhances the ability of the bone ends to unite. 29 In a study performed by Tranquilli Leali et al. 30 in Italy on 20 patients with gap non-union of the tibia, the result was union in all the cases; mean time of union being 4.5 months. In another study Marsh et al. 31 showed gap union in 40 out of 46 non-union cases treated with Ilizarov method, with a high level of patient satisfaction. Menon et al. 32 also concluded in their study that there is a role of Ilizarov ring fixator with nail retention in resistant long bone diaphyseal non-union and that this method could achieve high union rates where other methods failed. Several modifications have been undertaken to increase the efficacy of treatment with Ilizarov method and patient's acceptability, e.g., Rozbruch et al. 33 used a taylor spatial frame in two cases of hypertrophic gap non-union of the tibia with deformity for which distraction was utilized, yielding noticeable results. The duration of frame application is a disadvantage but when all other treatment modalities have failed, this technique is probably the only alternative and the only hope for many suffering patients, though the patient's compliance is important for a successful outcome. Conclusion We conclude that in patients with aseptic tibial nonunion, the Ilizarov technique is a safe and effective technique to improve their functional capacity and to promote complete union. Recommendations According to this study, we have seen good healing of gap nonunion in aseptic tibial nonunion by using Ilizarov fixation along with improvements in the daily activities. We highly recommend Ilizarov fixation procedure in aseptic tibial gap nonunion cases to increase chances of boney union leading to improve functional capacity of the patients. References 1. Chin KR, Nagarkatti DG, Miranda MA, Santoro VM, Baumgaertner MR, Jupiter JB. Salvage of distal tibia metaphyseal nonunions with the 90 degrees cannulated blade plate. Clin Orthop Relat Res 2003; 409: 241-9. 2. Helfet DL, Jupiter JB, Gasser S. Indirect reduction and tensionband plating of tibial non-union with deformity. J Bone Joint Surg Am 1992; 74: 1286-97. 3. Rosen H. Compression treatment of long bone pseudarthroses. Clin Orthop Relat Res 1979; 138: 154-66. 4. Court-Brown CM, Keating JF, Christie J, McQueen MM. Exchange intramedullary nailing. Its use in aseptic tibial nonunion. J Bone Joint Surg Br 1995; 77: 407-11. 5. Moed BR, Watson JT. Intramedullary nailing of aseptic tibial nonunions without the use of the fracture table. J Orthop Trauma 1995; 9: 128-34. 6. Richmond J, Colleran K, Borens O, Kloen P, Helfet DL. Nonunions of the distal tibia treated by reamed intramedullary nailing. J Orthop Trauma 2004; 18: 603-10. 7. Templeman D, Thomas M, Varecka T, Kyle R. Exchange reamed intramedullary nailing for delayed union and nonunion of the tibia. Clin Orthop Relat Res 1995; 315: 169-75. 8. Catagni MA, Guerreschi F, Holman JA, Cattaneo R. Distraction osteogenesis in the treatment of stiff hypertrophic nonunions using the Ilizarov apparatus. Clin Orthop Relat Res 1994; 301: 159-63. 9. Cattaneo R, Catagni M, Johnson EE. The treatment of infected nonunions and segmental defects of the tibia by the methods of Ilizarov. Clin Orthop Relat Res 1992; 280: 143-52. 10. Feldman DS, Shin SS, Madan S, Koval KJ. Correction of tibial malunion and nonunion with six-axis analysis deformity correction using the Taylor Spatial Frame. J Orthop Trauma 2003; 178: 549-54. 11. Schatzker J. Osteosynthesis in trauma. Int Orthop 1996; 20: 244-52. 12. Saleh M, Royston S. Management of nonunion of fractures by distraction with correction of angulation and shortening. J Bone Joint Surg Br 1996; 78: 105-9. 13. Paley D, Maar DC. Ilizarov bone transport treatment for tibial defects. J Orthop Trauma 2000; 14: 76-85. 14. Pugh K, Rozbruch SR. Nonunions and malunions. In: Baumgaertner MR, Tornetta P, eds. Orthopaedic Knowledge Update: Trauma 3. Rosemont, IL: American Academy of Orthopaedic Surgeons; 2005; pp 115-30. 15. Song HR, Cho SH, Koo KH, Jeong ST, Park YJ, Ko JH. Tibial bone defects treated by internal bone transport using the Ilizarov method. Int Orthop 1998; 22: 293-7. 16. Paley D, Catagni MA, Argnani F, Villa A, Benedetti GB, Cattaneo R. Ilizarov treatment of tibial nonunions with bone loss. Clin Orthop Relat Res 1989; 241: 146-65. 17. Dendrinos GK, Kontos S, Lyritsis E. Use of the Ilizarov technique for treatment of non-union of the tibia associated with infection. J Bone Joint Surg Am 1995; 77: 835-46. 18. Marsh DR, Shah S, Elliott J, Kurdy N. The Ilizarov method in nonunion, malunion and infection of fractures. J Bone Joint Surg Br 1997; 79: 273-9. 19. Rozbruch SR, Weitzman AM, Watson JT, Freudigman P, Katz HV, Ilizarov S. Simultaneous treatment of tibial bone and soft-tissue defects with the Ilizarov method. J OrthopTrauma 2006; 20: 197-205. 20. Paley D. Principles of Deformity Correction. Rev ed. Berlin: Springer- Verlag; 2005. 21. Paley D, Herzenberg JE, Tetsworth K, McKie J, Bhave A. Deformity planning for frontal and sagittal plane corrective osteotomies. Orthop Clin North Am 1994; 25: 425-65. 22. Rozbruch SR, Blyakher A, Haas SB, Hotchkiss R. Correction of large bilateral tibia vara with the Ilizarov method. J Knee Surg 2003; 16: 34-7. 23. Shtarker H, Volpin G, Stolero J, Kaushansky A, Samchukov M. Correction of combined angular and rotational deformities by the Ilizarov method. Clin Orthop Relat Res 2002; 402: 184-95. 24. Fragomen AT, Ilizarov S, Blyakher A, Rozbruch SR. Proximal tibial osteotomy for medial compartment osteoarthritis of the knee using the Taylor Spatial Frame. Tech Knee Surg 2005; 4: 175-83. J Pak Med Assoc (Suppl. 3)

29th Pak Orthocon 2015 S-185 25. Akhtar A, Shami A, Sarfraz M. Functional outcome of tibial nonunion treatment by Ilizarov fixator. Ann Pak Inst Med Sci 2012; 8: 188-91. 26. Menadue C, Raymond J, Kilbreath SL, Refshauge KM, Adams R. Reliability of two goniometric methods of measuring active inversion and eversion range of motion at the ankle. BMC Musculoskeletal Disorders 2006; 7: 60. doi:10.1186/1471-2474-7-60. 27. Dell P, Sheppard TC. Vascularised bone graft in the treatment of infected forearm nonunions. J Hand Surg 1984; 9: 653-8. 28. Ilizarov GA, Lediaev VI, Degtiarev VE. [Operative and bloodless methods of repairing defects of the long tubular bones in osteomyelitis.] Vestn Khir Im I I Grek 1973; 110: 55-9. 29. Ilizarov GA. The tension-stress effect on the genesis and growth of tissues. Part I. The influence of stability of fixation and soft-tissue preservation. Clin Orthop Relat Res 1989; 238: 249-81. 30. Tranquilli Leali P, Merolli A, Perrone V, Caruso L, Giannotta L. The effectiveness of the circular external fixator in the treatment of post-traumatic of the tibia nonunion. Chir Organi Mov 2000; 85: 235-42. 31. Marsh DR, Shah S, Elliott J, Kurdy N. The Ilizarov method in nonunion, malunion and infection of fractures. J Bone Joint Surg Br 1997; 79: 273-9. 32. Menon DK, Dougall TW, Pool RD, Simonis RB. Augmentative Ilizarov external fixation after failure of diaphyseal union with intramedullary nailing. J Orthop Trauma 2002; 16: 491-7. 33. Rozbruch SR, Helfet DL, Blyakher A. Distraction of hypertrophic nonunion of tibia with deformity using Ilizarov/Taylor Spatial Frame. Report of two cases. Arch Orthop Trauma Surg 2002; 122: 295-8.