KaVo ARCUS digma the new generation. What human senses can t capture.

Similar documents
KaVo PROTAR evo. Exciting design and function.

Exciting design and function.

Articulators. 5- Wax up and refining the occlusion for dental restorations.

Prosthodontics. Dental articulator. 1-Allow most of the prosthetic work to be done in the absence of the patient.

Anatomy and physiology of Temporomandibular Joint

Application of ARCUS digma I, II systems for full mouth reconstruction: a case report

We have simplified the. for you! Just a few steps to the articulator system of your choice! choose the perfect articulator for you!

Concepts of occlusion Balanced occlusion. Monoplane occlusion. Lingualized occlusion. Figure (10-1)

Operating Instructions PROTAR evo. Always on the safe side.

FULL DENTURE SYSTEM THE INHOUSE MOVEMENT

Jaw relation (Maxillomandibular relationship): any one of the infinite

The Effect of the Central Bearing Plate Form on the Fischer Angle

Dr Mohammed Alfarsi Page 1 9 December Principles of Occlusion

Horizontal Jaw Relation

Splint Appliance. Selection Guide. Great Lakes. See inside...

529-A Treatment and Management of the Edentulous Patient. Upon completion of this course the student should be able to:

Introduction to the Panadent System

Symposium on Occlusal Articulation. Mandibular Movement Recordings and Articulator Adjustments Simplified. Harry C. Lundeen, D.D.S.

Occlusion in complete denture

Jaw relation registration in RPD

ALTERNATE OCCLUSAL SCHEMES

SICAT FUNCTION TRACK REAL MOTION IN MOTION. Real 3D jaw motion for the first time

Implant and Tooth Supported Full-Mouth Rehabilitation with Hobo Twin-Stage Technique

Saudi Journal of Oral and Dental Research. DOI: /sjodr. ISSN (Print) Dubai, United Arab Emirates Website:

Re-evaluation of the Condylar Path as the Reference for Occlusion

AMERICAN ACADEMY OF IMPLANT DENTISTRY

Unique Dental Supply. Catalog We Bring World Quality Products to Enhance your Business QUALITY PRODUCTS SINCE 1974

How to Design an Ideal Maxillary Plane of Occlusion For Fixed or Removeable Prosthetics

Lab Procedure Prior to Try-in

Horizontal jaw relations: The relationship of mandible to maxilla in a

Maximizing Insurance Benefits

3000 Series Articulator System

REVIEW ARTICLE VIRTUAL ARTICULATORS IN DENTISTRY-A REVIEW

SICAT FUNCTION & OPTIMOTION. Individual functional treatment

The mission of our company is the development of an individual approach in functional dentistry.

Clinical Study Comparison of Selected Kinematic Facebows Applied to Mandibular Tracing

Tooth preparation for posterior fi xed partial denture (FPD) Tooth preparation for anterior fi xed partial denture (FPD)

Principle of Occlusion

PREC ISE & ECONOM IC AL. The reliable Scanner Generation by CADstar

Comparisons of Condylar Movements with the Functional Occlusal Clutch and Tray Clutch Recording Methods in CADIAX system

There is one thing different. Everything.

ACTIVITY SCANNER NEW. 3D Dental Scanner made in Germany.

Design of a Virtual Articulator for the Simulation and Analysis of Mandibular Movements in Dental CAD/CAM

Registration: Stage II intermaxillary relations J. F. McCord, 1 and A. A. Grant, 2

Diagnosis. overt Examination. Definitive Examination. History. atient interview. Personal History. Clinical Examination.

Linear Occlusion. By Dr. John P. Frush

Connect your Scanner to SomnoMed Canada. SOMGauge Protrusive Bite Recording - Manual. Scanning Impressions - Lower and Upper

AN EVALUATION OF MANDIBULAR BORDER MOVEMENTS THEIR CHARACTER AND SIGNIFICANCE

Full mouth occlusal rehabilitation; by Pankey Mann Schuyler philosophy

Supplies. Online. Reliability at a great value. Dentaurum. shop.dentaurum.com

How to provide intraoral scans to SomnoMed for the production of SomnoDent device.

The first choice for design and function.

JCDP ORIGINAL ARTICLE ABSTRACT INTRODUCTION

KaVo Endodontic Program. Finger-tip feel for sensitive movements.

Occlusal rehabilitation of posterior fixed prostheses: A clinical report

Start safe with affordable KaVo quality.

See the end from the beginning

STL. inside. ineos Blue: Precision, Speed and Control. THE SCANNER WITH Bluecam TECHNOLOGY

Articulator Instructions

INSIGHT & INNOVATION. Envelope of Parafunction: 7 Steps of Treatment Planning Many methods and theories have been

Occlusion & Prosthodontics

Bite-Tab Compound Disks 180/box Накусочные таблетки для фиксации прикусной вилки лицевой дуги. Features & Benefits. Bite-Tray регистраты 50/Bag

ADHESIVE DENTISTRY DR. JAVIER VASQUEZ AN ORDINARY BUT VERY PASSIONATE DENTIST/MASTER CERAMIST DENTAVANTGART MAXIMUM PROTOCOL SIMPLIFICATION

Kois Dento-Facial Analyzer System Instructions

Protocol for SAM Articulator/Surgical Simulation Planning

STANDARDS & GUIDELINES

Full mouth rehabilitation of a patient with enamel hypoplasia using hobo s twin-tables technique for occlusal rehabilitation-a case Report

A Critical Evaluation of different methods of recording centric jaw relation of completely edentulous individuals - An In Vivo Study *

Digital, but without loss of function

Introduction to Occlusion and Mechanics of Mandibular Movement

1 Lecture hour per week; 3 credits. CUNY Certification in reading, writing and math.

Analog Selector Instructions

Restoring Severe Anterior Wear Cases; A Step by step Process

Shadeguides Finding the Centric Relation The Kois Deprogrammer

Reference to primary publication Properties of alginates in ZWP 4/2014 Xantalgin Crono - Introduction

LAB APPLIANCE FABRICATION REQUIREMENTS

International Journal of Allied Medical Sciences

A Comparative Evaluation of Static and Functional Methods for Recording Centric Relation and Condylar Guidance: A Clinical Study

Digital, but without loss of function

NEW. The SmartFix Concept Prosthetic solution on tilted implants. SmartFix

hydrorise implant SIMPLY ACCURATE High-rigidity addition silicone

PREDICTABILITY IN COMPREHENSIVE RECONSTRUCTION Bite registration and recovery process for comprehensive reconstructive cases.

Annals and Essences of Dentistry

JCDP ORIGINAL ARTICLE ABSTRACT INTRODUCTION

Ascertaining of temporomandibular disorders (TMD) with clinical and instrumental methods in the group of young adults

Combi ArtiCulAtor SyStem instruction manual

A Systematic Approach for Rehabilitation of Occlusion in Fixed Partial Denture

Visalys Temp. Simply Professional. fracture-resistant, convenient, convincing. The temporary crown and bridge material from Kettenbach

(51) Int Cl.: A61C 11/00 ( )

The Hanau Modular Articulator System 194 Fixed 11 cm width, adjustable Radial-Shift Guidances. Illustrated Instruction Manual

Occlusion and removable prosthodontics

Tune in on life with SCOLAbuddy. A new fm receiver from Widex

Full-mouth rehabilitation of a patient with severe attrition using the Hobo twin-stage procedure

FRAMEWORK MANAGEMENT. _ Construction of temporaries Instruction for use

ESTHETIC AND FUNCTIONAL REHABILITATION OF THE PATIENT WITH SEVERELY WORN DENTITION USING TWIN STAGE PROCEDURE: A CASE REPORT

» Guided Surgery. by MEDENTiKA « MEDENTIGUIDE SURGERY MANUAL MICROCONE. IPS Implant systems

The Application of the HIP-Analyzer for the Evaluation of the Maxillary Occlusal Plane Topography

Complex Occlusal Rehabilitation: A Case Report

The 4 views of DSD! The Dynamic Dento-Facial Documentation (video)!

Transcription:

What human senses can t capture.

What human senses can t capture. Digma can. Integration in the treatment procedure. Self-sufficient, when Digma is to be located in differing positions in the practice. Integrative, when the possibility exists of integrating into the assistant s unit (KaVo E80). Via USB or wireless link to your network, or quite simply just store on a data card. Economic aspects are an important foundation of the dental practice. Quick findings and their complete documentation are the basis of profound diagnostics. Competence in the development of dental treatment units and measuring systems for functional diagnosis is the basis of the new Digma from KaVo. For the first time, a completely integrative solution has succeeded. Mechanically, by adaptation into the assistant s and the multi-media units. Softwaretechnically, in the KaVo KID operating surface.

Statics for prosthodontic therapy. Determining the centric mandibular position. Using the new Digma, it has been successful for the first time to transfer a desired centric position under computer control into a centric registration. Digital Controlled Position. Dynamics for prosthodontic therapy. Your articulator becomes (almost) a patient. Manually-guided centric A manually-guided centric condyle position (black cross) in relation to a protrusion trace can be displayed on the monitor. The selected centric position can be moved in relation to the protrusion trace, as required. With a subsequent continuous measurement (green cross), this position can then be transferred to a registration under computer control. A few small excursive movements by the patient are sufficient to calculate all settings for programming a fully-adjustable articulator (PROTAR Digma). In less than 5 min., an experienced operator can ascertain and document all important settings for programming the articulator (e.g. condylar inclination, Bennett angle, ISS, shift angle). For the first time, even settings for programming articulators of other manufacturers can be calculated with the Digma system. Ask your dealer. Adduction zone After several bite movements (max 20) a point is displayed, which lies 20 mm behind the incisal edge and approximately on the occlusal plane. With each closure of the dentition, the analysis is refined. The boundaries whereby which points should be considered in the evaluation can be selected as desired. The centre of this adduction zone (blue cross) corresponds to the habitual occlusion and is associated to the position of the TMJ. With a subsequent continuous measurement, the current position of the mandible is displayed (yellow cross). The operator guides the mandible into a position in which both the yellow and blue cross cover each other, then encodes this by plastic registration material. For the documentation of the articulator programme settings, a clear, informative report is automatically generated. This can be stored, printed or sent by e-mail to your laboratory. The displayed curves provide information about all relevant movements in the temporomandibular joints and at the incisal point. Gothic arch This method is primarily designed for the functionally-disturbed patient, but is also suitable for edentulous cases. Here, the Digma intra-oral registration support pin is placed in the patient s mouth. The crossing-point from several protrusions and laterotrusions ( arrow-head ) delineates the sought-after centric position. In a continuous measurement (yellow cross), the lower jaw can be adjusted to either this centric occlusion or a freely defined position, and encoded by registration material.

Efficient findings. Your support for a profound diagnosis. Therapy according to the findings. Mandibular position following movement analysis. Clinical functional analysis combined with an electronic analysis of movement is the first important step for diagnosing the need for an initial treatment of function before carrying out restorative measures, so as not to overlook any malfunctions. Digma undertakes the documentation of the 3D lower jaw movement in clear, representative reports and stores all relevant data. The automatic error-corrected display of condylar and incisal movements in the three oral planes; together with the study of movements of the condyles on the right and left sides at the same point of time in the form of the kinematic axis, can all provide information regarding movement limitations, un-coordination or hyper-mobility. The probable causes thereto can possibly be discovered in the arthrogenic, myogenic or occlusal regions. Should functional disturbances be recognised in the movement analysis, a new therapeutic position can be defined with the help of Digma. This can be adopted, for example, as the therapeutic start position of centric occlusion in a splint or a provisional prosthesis. The new Digma guides the operator through the movement analysis. From 6 fixed movement procedures, important information about the patient is ascertained. In addition, self-selected movements can be defined and recorded. Both condyle positions and the movement of the kinematic axis are displayed three-dimensionally. By selecting the desired movement recordings ( green tick-mark ) it is possible to display these overlapping. Individual comments can be inserted at any desired point of the lower jaw movements. For this purpose, preferably up to 3 movements in which the irregularities appear should be carried out. Based on the visualisation of the movement sequences, the new therapeutic position can be specifically selected. This selected position is finally transferred into a registration under computer control. As a final step, by using Digma it can be checked whether the patient is attuned to the registration in the new therapeutic position. An easy-readable report is created for documentation of the appropriate movement analysis. The mobility of the TMJ and the incisal point, as well as their exact progression, are stored as graphics. For appraisal of the treatment progression, up to three movement analyses can be displayed overlapping.

EAEF. Analysis of pain location in the TMJ. Import/Export. Your practice PC for storing and analysing all measured values. Production of dynamic splints. All information which has been recorded and analysed by Digma from the patient is stored in a clearlyreadable way in the KaVo Digma/KID software. The patient s basic data is transferred to this from your practice software. Electronic Analysis of Etiological Factors (according to Prof. A. Bumann) The new Digma assists the operator with the localisation of the pain position(s) in the stomatological system. The analysis programme simulates important steps from the findings. Further steps for the pain position analysis can be easily integrated. In Replay modus, all measurements can be retrieved from the data bank and further displayed. A dentist doesn t need advice - at most, he gives it to others! All the patient s data can be transmitted by e-mail or data carrier to other colleagues or to the laboratory. Similarly, this can carry out all the analysis steps (providing the Digma software is also available). A mutual evaluation, or specific instructions to the laboratory, are therefore greatly simplified. KaVo ARCUS evo face bow. The new KaVo face bow is a real all-rounder. The innovative, patented adjustment for the width of the face allows for universal applications in the dental practice. Can be used as an arbitrary face bow, or a measuring bow for the Digma SD/USB/Wireless. Consequently, the new KaVo face bow becomes the first step to the electronic measuring system Digma. In 3 minutes to the upper jaw model position The ARCUSevo face bow efficiently captures the position of the upper jaw model in relation to the arbitrary hinge axis. Occlusal errors, above all by raising or lowering of the bite, are thereby prevented. All measuring steps of the pain analysis are clearly displayed on the left hand side of the screen. The operator guides the patient into the respective position alternatively, the patient is requested to carry out the required action. Painful lower jaw positions are illustrated in red on the report via the pain button. Thanks to the clear portrayal on the PC screen, it can be explained to the patient which of his actions force the lower jaw into a painful position. As a therapeutic step from the pain analysis and with assistance of the Digma analysis software, a dynamic splint can be produced in the KaVo PROTAR articulator. Guided excursive movements which are portrayed on the PC display and specifically aimed at the pain position allow the Digma to calculate a dynamic splint. Mat.-Nr.: 1.005.0900 ARCUSevo face bow ARCUSdigma measuring bow

KaVo ARCUSdigma Versions ARCUSdigma SD Ref. Nr. 1.005.2300 Software Modules: Articulator programming Hand-guided centric relation Lower jaw movement analysis EPA - Electronic position analysis of LJ position Selectable Reference Axis: KaVo Transfer System Cinematic axis Arbitrary axis Individual centric axis Compatible Articulators: KaVo PROTAR/evo articulators Data Transfer: Via SD-card to PC Upgradable: ARCUSdigma USB (with Upgrade SD-USB - Ref. Nr. 1.005.4117) ARCUSdigma Wireless (with Upgrade SD-Wireless - Ref. Nr. 1.005.4118) Accessories and Optionals: PROTARevo Digma Ref. Nr. 1.005.4121 Mounting-set for KaVo Estetica E80 assistant delivery unit Ref. Nr. 1.005.4127 ARCUSdigma USB Ref. Nr. 1.005.2301 Software Modules: Articulator programming Hand-guided centric relation Centric relation via adduction field Centric relation via gothic arch Lower jaw movement analysis LJ positioning after movement analysis EPA - Electronic position analysis of LJ position Optional Software Modules: EAEF module based on Prof. A. Bumann method for detection of painful LJ positions and for design of dynamic splints (Ref. Nr. 1.005.4122) EMG Analysis 2 channels EMG skin electrodes for measurement of muscle activity (Ref. Nr. 1.005.4123) Selectable Reference Axis: KaVo Transfer System Cinematic axis Arbitrary axis Individual centric axis Compatible Articulators: KaVo PROTAR/evo articulators, SAM, Girrbach, Stratos, Panadent, Denar on demand ARCUSdigma Wireless Ref. Nr. 1.005.2302 Software Modules: Articulator programming Hand-guided centric relation Centric relation via adduction field Centric relation via gothic arch Lower jaw movement analysis LJ positioning after movement analysis EPA - Electronic position analysis of LJ position Optional Software Modules: EAEF module based on Prof. A. Bumann s method for detection of painful LJ positions and for design of dynamic splints (Ref. Nr. 1.005.4122) EMG Analysis 2 channels EMG skin electrodes for measurement of muscle activity (Ref. Nr. 1.005.4123) Selectable Reference Axis: KaVo Transfer System Cinematic axis Arbitrary axis Individual centric axis Compatible Articulators: KaVo PROTAR/evo articulators, SAM, Girrbach, Stratos, Panadent, Denar on demand KaVo ARCUS digma Product benefits. Data Transfer: Via USB-cable online to PC Upgrade: ARCUSdigma Wireless (with Upgrade USB-Wireless Ref. Nr. 1.005.4119) Accessories and Optionals: PROTARevo Digma Ref. Nr. 1.005.4121 EAEF Module Ref. Nr. 1.005.4122 EMG Analysis Ref. Nr. 1.005.4123 Mounting-set for KaVo Estetica E80 assistant delivery unit Ref. Nr. 1.005.4127 Data Transfer: Via KaVo wireless module to PC Accessories and Optionals: PROTARevo Digma Ref. Nr. 1.005.4121 EAEF Module Ref. Nr. 1.005.4122 EMG Analysis Ref. Nr. 1.005.4123 Mounting-set for KaVo Estetica E80 assistant delivery Ref. Nr. 1.005.4127 Innovative Mechanical or electronic face bow in one unit Broad range of applications for the daily practice workflow - Centric relation - Articulator programming also for non-kavo articulators - Jaw movement analysis - New therapeutic lower jaw positioning after jaw movement analysis e.g. for splint-therapy - EAEF module for detecting painful lower jaw positions according to Prof. Bumann s method optional - EMG recording - optional Communicative Data can be stored offline on an SD-card, or recorded and stored online in the PC through a USB or wireless connection Online demonstration of all lower jaw movements for patient and dentist Data export to the laboratory or to other colleagues Integrative Mechanical adaptation into the assistant s units of the KaVo Estetica E80 Software integration into the intelligent KaVo KID data-assistant for an optimum connection to your accounting software

Mat.-Nr. 1.001.2889 12/07/en We reserve the right to make technical modifications. Slight colour differences are due to the printing process. Copyright KaVo Dental GmbH. KaVo Dental GmbH D-88400 Biberach/Riß Telefon +49 7351 56-0 Fax +49 7351 56-1488 www.kavo.com