Anterior Spinal Artery and Artery of Adamkiewicz Detected by Using Multi-Detector Row CT

Similar documents
Paraplegia and paraplesis secondary to spinal cord ischemia

CT angiography techniques. Boot camp

Anatomical Study of Blood Supply to the Spinal Cord

Paraplegia in endovascular repair of TAA and in TEVAR: Incidence, prevention and therapy. Johannes Lammer Medical University Vienna, Austria

Customizing Contrast Injection for Body MDCT: Algorithmic Approach

Magnetic Resonance Angiographic Localization of the Artery of Adamkiewicz for Spinal Cord Blood Supply

Assessment of Spinal Cord Circulation and Function in Endovascular Treatment of Thoracic Aortic Aneurysms

Communicating Vein between the Left Renal Vein and Left Ascending Lumber Vein: Incidence and Significance on Abdominal CT

Multidetector CT has enlarged our view of human vascular

Gemstone Spectral Imaging quantifies lesion characteristics for a confident diagnosis

Origins of the Segmental Arteries in the Aorta: An Anatomic Study for Selective Catheterization with Spinal Arteriography

Role of Three-Dimensional Rotational Angiography in the Treatment of Spinal Dural Arteriovenous Fistulas

Selective Visceral Perfusion during Thoracoabdominal Aortic Aneurysm Repair

INTRODUCTION. Jong Gyu Kim, Soo Hyang Lee. Original Article

The Adamkiewicz artery (arteria radicularis magna)

Detection of the Adamkiewicz artery in computed tomography of the thorax and abdomen

Renal vascular evaluation with 64 Multislice Computerized Tomography Daniela Stoisa, Fabrizzio E. Galiano, Andrés Quaranta, Roberto L.

Spinal dural arteriovenous fistulas (SDAVF) are the most commonly

Improvement of Image Quality with ß-Blocker Premedication on ECG-Gated 16-MDCT Coronary Angiography

Scientific Exhibit. Authors: D. Takenaka, Y. Ohno, Y. Onishi, K. Matsumoto, T.

Utility of Variable Helical Pitch CT Scanning Technique for CT Angiography of Aortoiliac and Lower Extremity Arteries

MODERN METHODS FOR TREATING ABDOMINAL ANEURYSMS AND THORACIC AORTIC DISEASE

Arteriovenous (AV) shunts of the spinal cord and its meninges

Lung Perfusion Analysis New Pathways in Lung Imaging. Case Study Brochure PLA 309 Hospital

Utility of CT angiography for pre-operative evaluation of robotic-assisted minimally invasive mitral valve surgery.

ROLE OF CONTRAST ENHANCED MR ANGIOGRAPHY IN AORTIC COARCTATION

Ex. 1 :Language of Anatomy

Case 9799 Stanford type A aortic dissection: US and CT findings

Aortic Coarctation: Evaluation with Computed Tomography Angiography in Pediatric Patients

Percutaneous Approaches to Aortic Disease in 2018

How to manage the left subclavian and left vertebral artery during TEVAR

Variations of pulmonary vein drainage critical for lung resection assessed by three-dimensional computed tomography angiography

Non Contrast MRA. Mayil Krishnam. Director, Cardiovascular and Thoracic Imaging University of California, Irvine

Ultrasound. Computed tomography. Case studies. Utility of IQon Spectral CT in. cardiac imaging

Case Report 1. CTA head. (c) Tele3D Advantage, LLC

Comparison of multidetector-row computed tomography findings of IgG4-related sclerosing cholangitis and cholangiocarcinoma

Feasibility of contrast agent volume reduction on 640-slice CT coronary angiography in patients with low heart rate

Paraplegia prevention branches: A new adjunct for preventing or treating spinal cord injury after endovascular repair of thoracoabdominal aneurysms

ECG Gated CT Aorta in Transcatheter Aortic Valve Implantation

Whole brain CT perfusion maps with paradoxical low mean transit time to predict infarct core

Variations in Surgical Anatomy of the Portal Vein in Living Donor Liver Transplantation

Vascular CT Protocols

Disclosures: T. Yoshii: None. T. Yamada: None. T. Taniyama: None. S. Sotome: None. T. Kato: None. S. Kawabata: None. A. Okawa: None.

Thoracic aortic trauma A.T.O.ABDOOL-CARRIM ACADEMIC HEAD VASCULAR SURGERY DEPARTMENT OF SURGERY UNIVERSITY OF WITWATERSRAND

Evolving Strategy and Results of Spinal Cord Protection in Type I and II Thoracoabdominal Aortic Aneurysm Repair

A rare case: Coronary sinus thrombosis

Cardiac CT - Coronary Calcium Basics Workshop II (Basic)

1Pulse sequences for non CE MRA

MR Imaging of Spinal Cord Arteriovenous Malformations at 0.5 T: Study of 34 Cases

Anatomical Terminology

Liver Perfusion Analysis New Frontiers in Dynamic Volume Imaging. Case Study Brochure Chang Gung Memorial Hospital.

CT perfusion in Moyamoya disease

Time-resolved Magnetic Resonance Angiography for assessment of recanalization after coil embolization of visceral artery aneurysms

FOR CMS (MEDICARE) MEMBERS ONLY NATIONAL COVERAGE DETERMINATION (NCD) FOR COMPUTED TOMOGRAPHY:

Length Measurements of the Aorta After Endovascular Abdominal Aortic Aneurysm Repair

128-slice dual-source CT coronary angiography using highpitch scan protocols in 102 patients

Liver 4 Phase CT Abdomen WO W - NC.A.V.D

Cover Page. The handle holds various files of this Leiden University dissertation.

B. CT protocols for the spine

Management of the persistent sciatic artery with coexistent aortoiliac aneurysms; endovascular and open techniques.

Treatment options for endoleaks: stents, embolizations and conversions

S. Inagawa, N. Yoshimura, Y. Ito; Niigata/JP spinal sacral areteriovenous fistulae, CTA, MRA /ecr2010/C-2581

Modified candy-plug technique for chronic type B aortic dissection with aneurysmal dilatation: a case report

Combination of Myogenic and Neurogenic Motor Evoked Potential Monitoring During Thoracoabdominal Aortic Surgery

Detectability of unruptured intracranial aneurysms on thinslice non-contrast-enhanced CT

The posterior abdominal wall. Prof. Oluwadiya KS

Multislice CT angiography in abdominal aortic aneurysm treated with endovascular stent grafts: evaluation of 2D and 3D visualisations

Transvenous Embolization of Cavernous Sinus Dural Arteriovenous Fistulas with Shunts Involving the Laterocavernous Sinus

Computed tomography. Department of Radiology, University Medical School, Szeged

Animesh Rathore, MD 4/21/17. Penetrating atherosclerotic ulcers of aorta

Bottom up cardiac CT for CABG assessment to resolve breathing artefact

Medical Review Guidelines Magnetic Resonance Angiography

2004;77:800 4 MSCT OF CORONARY ARTERY BYPASS GRAFTS. Results. CABG With Adequate Diagnostic Quality

SANWICH TECHNIQUE TO REDUCE COMPLICATIONS WHEN TREATING BILATERAL INTERNAL ILIAC ARTERY

Influence of Perioperative Hemodynamics on Spinal Cord Ischemia in Thoracoabdominal Aortic Repair

CT Versus MR for the Runoff

Neurological Complications of TEVAR. Frank J Criado, MD. Union Memorial-MedStar Health Baltimore, MD USA

ACD. The Journal of Thoracic and Cardiovascular Surgery c Volume 139, Number 3 655

SDAVFs are rare acquired vascular lesions predominantly

Haemodynamically unstable patient with chest trauma

Neuromonitor-guided repair of thoracoabdominal aortic aneurysms

Acute Type B dissection. Closure of the infra diaphragmatic tear: how and when?

Chapter 4. Department of Cardiology, Leiden University Medical Center, Leiden, The Netherlands. Department of Radiology,

North American Society of Cardiovascular Imaging Annual Meeting, Baltimore MD, October 15-18, Tips and Tricks in Vascular Imaging

debris + 3 debris debris debris Tel: ,3

Multislice CTA for Renal Artery Stenting

Likes ML, Johnston TA. Gastric pseudoaneurysm in the setting of Loey s Dietz Syndrome. Images Paediatr Cardiol. 2012;14(3):1-5

The Thoracic wall including the diaphragm. Prof Oluwadiya KS

Daniela Branzan MD, Department of Vascular Surgery and Department of Interventional Angiology University Hospital Leipzig

Threshold Selection for CT Angiography Shaded Surface Display of the Renal Arteries

Variations in arterial supply to the lower lumbar spine

B-Flow, Power Doppler and Color Doppler Ultrasound in the Assessment of Carotid Stenosis: Comparison with 64-MD-CT Angiography

CLINICAL PRESENTATION AND RADIOLOGY QUIZ QUESTION

No Disclosure. Aortic Dissection in Japan. This. The Challenge of Acute and Chronic Type B Aortic Dissections with Endovascular Aortic Repair

CT of Acute Thoracic Aortic Syndromes Stuart S. Sagel, M.D.

The SPIDER-Graft for Thoracoabdominal Aortic Repair a feasability study in pigs

The role of abdominal CT and MRI in detection of complications after transplantations of liver, kidney and pancreas.

Combined Anatomical and Functional Imaging with Revolution * CT

The role for contrast-enhanced ultrasonography outside of focal liver lesions

Transcription:

AJNR Am J Neuroradiol 24:13 17, January 2003 Anterior Spinal Artery and Artery of Adamkiewicz Detected by Using Multi-Detector Row CT Kohsuke Kudo, Satoshi Terae, Takeshi Asano, Masaki Oka, Kenshi Kaneko, Satoshi Ushikoshi, and Kazuo Miyasaka BACKGROUND AND PURPOSE: Our purpose was to evaluate the visualization of the artery of Adamkiewicz (AKA) and the anterior spinal artery (ASA) by using multi-detector row CT. Preoperative detection of the AKA and ASA is important for prevention of ischemic complications of thoracoabdominal aortic surgery. METHODS: Data from contrast-enhanced CT of the abdomen of 19 consecutive patients with known or suspected liver disease were evaluated. The scanning range was set from the level of the diaphragm to the lower edge of the liver. After bolus injection of contrast material (100 ml of iohexol, 350 mgi/ml, 5 ml/s), arterial phase scans were obtained by using a four-channel multi-detector row CT scanner. The scanning parameters included a detector row configuration of 4 2 mm, a pitch of 5:1, a gantry rotation speed of 0.5 s, 120 kvp, and 150 mas. Arterial phase coronal multiplanar reconstruction scans obtained parallel to the spinal cord were evaluated by two neuroradiologists. The detectability of ASA and AKA was analyzed. RESULTS: The AKA was visualized on the scans of 13 of 19 patients (68%). The segmental level of AKA origin ranged from T10 to L2. The AKA originated from the left side in nine patients (69%) and the right side in four patients (31%). The ASA was visualized on the scans of all patients (100%). For 16 of the 19 patients, the ASA was detected in its full length from the cranial edge of the scan range. However, the ascending branch of the ASA distal to the junction of the AKA was not detected for the remaining three patients. CONCLUSION: The AKA and ASA can be visualized by using multi-detector row CT with the use of IV administered contrast material. Multi-detector row CT could be a useful tool in the evaluation of spinal vascular structures. Received January 8, 2002; accepted after revision March 18. Presented in part at the 39th Annual Meeting of the American Society of Neuroradiology, 2001. From the Department of Radiology, Hokkaido University Graduate School of Medicine, Sapporo, Japan. Address reprint requests to Kohsuke Kudo, Hokkaido University Graduate School of Medicine, Department of Radiology, N 15, W 7, Kita-ku, Sapporo, Japan, 060-8638. American Society of Neuroradiology Ischemic complication of the spinal cord after surgery of the thoracoabdominal aorta is a rare but serious event. The anterior two thirds of the spinal cord receive blood supply from the anterior spinal artery (ASA), which extends along the full length of the spinal cord (1). The ASA may be narrow at the thoracolumbar area and receives blood supply from the largest anterior radiculomedullary artery, called the artery of Adamkiewicz (AKA). The ASA and AKA play an important role in preventing spinal cord ischemia at the thoracolumbar area. The causative factors for spinal cord ischemia after surgery of the thoracoabdominal aorta include systemic hypotension, prolonged aortic clamping, embolization, and interruption of internal iliac artery circulation (2). Although interruption of the AKA is not the sole cause of spinal cord ischemia (3), there have been reports of the importance of reattachment of the segmental arteries related to the AKA (4 6). The AKA usually arises from the ninth intercostal artery to the second lumbar artery (1, 7). Although selective spinal arteriography is required to show the accurate level of AKA origin (6), a recently developed less invasive method of MR angiography could be used to detect AKA. It has been reported that the successful detection rate of AKA by MR angiography is 69% (8, 9). CT angiography is another less invasive method with which to visualize small vessels. It has higher spatial resolution than does MR angiography, especially if a multi-detector row system is used. To our knowledge, there are few reports on visualization of intradural vessels by using contrast-enhanced CT angiography. The purpose of this study was to assess the visualization of ASA and AKA by using multi-detector row CT. Methods Participants Nineteen consecutive patients with known or suspected liver disease underwent contrast-enhanced CT of the abdomen as a 13

14 KUDO AJNR: 24, January 2003 TABLE 1: List of Patients and Results Patient No. Age (yr) Sex Background Scanning Range Range of ASA Detected Level of AKA Origin Upper Limit Lower Limit Upper Limit Lower Limit 1 65 F Chronic hepatitis T8 L2 T10 T11 L1 L2 Right T11 2 52 F Liver tumor T8 T9 L2 L3 U L1 L2 Left T10 3 54 M Post-liver transplantation (donor) T9 L2 L3 U T12 L1 Left T10 4 76 M HCC T9 L2 L3 T10 T11 T12 L1 Left T11 5 71 M HCC T9 L2 L3 U T12 L1 N.D. 6 57 F Echinococcosis T9 L2 U L1 L2 N.D. 7 55 F Liver cirrhosis T9 T10 L3 L4 U L Left T10 8 51 M HCC T9 T10 L3 U T12 L1 Right T11 9 73 M HCC T9 T10 L2 L3 U L1 L2 N.D. 10 60 M HCC T9 T10 L2 U T11 T12 Left T10 11 32 M Post-liver transplantation (recipient) T10 L3 L4 U L12 L1 Right T11 12 51 M Liver hemangioma T10 L3 L4 U L2 L3 N.D. 13 52 M HCC T10 L3 U L Left L1 14 56 M HCC T10 L2 L3 U L Right T12 15 48 F Post-liver transplantation (recipient) T10 T11 L4 L5 T11 T12 L1 L2 Left L2 16 68 M Autoimmune hepatitis T10 T11 L3 U T12 L1 Left T11 17 25 M Post-liver transplantation (recipient) T11 L4 U T12 L1 N.D. 18 64 M HCC T11 L3 U T12 L1 Left L1 19 58 M Liver cirrhosis T11 L3 U T12 L1 N.D. Note. ASA indicates anterior spinal artery; AKA, artery of Adamkiewicz; F, female; M, male; HCC, hepatocellular carcinoma; U, upper limit of scanning range; L, lower limit of scanning range; N.D., not detected. routine part of liver investigation. The age of the patients ranged from 25 to 73 years (mean, 56.2 years). Fourteen male and five female patients were included. Among the 19 patients, 12 had liver cirrhosis or chronic hepatitis, with or without hepatocellular carcinoma; three had other types of liver tumor or tumorous lesions; and four had undergone liver transplantation. All patients were confirmed to have no aortic disease and no neurologic symptoms. Scanning Protocol All scans were obtained on a four-channel multi-detector row CT scanner (Aquilion; Toshiba Medical Systems, Tokyo, Japan). A 19- or 20-gauge catheter was inserted into a superficial vein at the antecubital fossa, forearm, or dorsum of the hand. One hundred milliliters of iohexol (350 mg/ml iodine) was injected at a rate of 5 ml/s. The scanning range was set from the level of the diaphragm to the lower edge of the liver. An automatic bolus tracking technique monitoring aortic attenuation was used to obtain arterial dominant phase scans. Portal venous phase and delayed phase scans were also acquired to evaluate liver disease, although only the arterial phase scans were used in this study. Technical parameters included a detector row configuration of 4 2 mm, a pitch of 5:1, a gantry rotation speed of 0.5 s, 120 kvp, and 150 mas. Data Processing and Scan Evaluation After data acquisition, axial arterial phase scans were reconstructed with a field of view of 20 cm and a section interval of 0.4 mm to render isotropic voxel data. Oblique-coronal multiplanar reconstruction scans along the long axis of the spinal cord were created with a section thickness of 1.2 mm and a section overlap of 50%. The multiplanar reconstruction scans were displayed on the scanning workstation. Identification of the ASA and AKA on the multiplanar reconstruction scans was performed by two neuroradiologists (K.K., S.T.) who were in consensus. A vessel placed on the anterior midsagittal surface of the spinal cord was diagnosed as the ASA. The AKA was identified as the vessel that ascended toward the anterior midsagittal surface of the spinal cord from the intervertebral foramen and joined the ASA via a characteristic hairpin configuration. The range of the ASA and the segmental level of the AKA origin were recorded. Results The results are summarized in the Table. The actual scanning ranges were different among the patients, because the scan was aimed to include the whole liver. The upper limit ranged from T8 to T11, depending on the level of the diaphragm, and the lower limit ranged from L2 to L4 L5, depending on the size of the liver. The AKA was shown on the scans of 13 (68%) of 19 patients. The segment level of the AKA origin ranged from T10 to L2. The AKA originated from the left side in nine patients (69%) and from the right side in four patients (31%). The ASA was visualized on the scans of all the patients. On the scans of three of the 19 patients, the AKA and the caudal portion of ASA distal to the junction of AKA were shown, but the cranial portion of the ASA was not detected. On the scans of 16 of the 19 patients, the ASA was detected in its full length from the cranial edge of the scanning range. On the scans of 10 of the 16 patients, the AKA and both cranial and caudal portions of the ASA distal to the junction of AKA were detected (Figs 1 3 ). On the scans of six of the 16 patients, only the ASA was visualized and the AKA was not detected (Fig 4). Discussion The AKA usually arises from the level of the ninth intercostal artery to the second lumbar artery (1). Be-

AJNR: 24, January 2003 MULTI-DETECTOR ROW CT 15 FIG 1. CT scans obtained from patient 2, a 52-year-old woman. A, Coronal multiplanar reconstruction scan shows the ASA along the anterior midsagittal surface of the spinal cord (small white arrows). The large radiculomedullary artery (black arrow), which is defined as the AKA, arises from the left T10 level and joins the ASA. Both the ascending and descending branches of the ASA distal to the junction with the AKA are seen, but the ascending branch is narrower than the descending branch. The spinal branch (curved white arrow) arises from the left 10th intercostal artery (large white arrow). B, On the dorsal section of the coronal view, the continuity of the radiculomedullary artery and intercostal artery (large white arrow) via the spinal branch (curved white arrow) is confirmed. C and D, Axial scans show the ASA (small white arrows) and AKA (black arrows) in the dural sac. The continuity of the intercostal artery (large white arrow), spinal branch (curved white arrows), and radiculomedullary artery (black arrows) is also seen. E, Curved multiplanar reconstruction scan allows the visualization of the continuity of the intercostal artery (large white arrow), spinal branch (curved white arrow), radiculomedullary artery (black arrow), and ASA (small white arrows) on a single section. The change of caliber of these vessels is also seen. cause the scanning data used in this study were those of routine abdominal CT aimed for the evaluation of liver disease, the scanning range was planned to cover the liver. Considering that it is not desirable to administer extra doses of irradiation, the scanning range was not extended to cover the whole area of possible AKA origin. In this study, the lower limit of the scanning range was at or below the L2 level in all patients, which is the level that is adequate to cover the lower origin of the AKA. However, the upper limit of the scanning range varied from the T8 to T11 level, and the AKA could have been located cranial to the scanning range in

16 KUDO AJNR: 24, January 2003 FIG 2. CT scans obtained in patient 3, a 54-year-old man. A and B, Coronal scans show ASA (small white arrow) and AKA (black arrows). Thorough inspection reveals that the top of the hairpin curve is visualized at the upper edge of the scan. The continuity of the 10th intercostal artery (large white arrow), spinal branch (curved white arrow), and radiculomedullary artery (black arrows) is obscure because of close attachment of these vessels to the bone as a result of narrow intervertebral foramen. patients for whom AKA could not be detected. The inadequacy of the upper limit of the scanning range was the limitation of this study. The detection ratio of AKA was 68% by using multi-detector row CT. It is comparable with the MR angiography results reported by Yamada et al (8, 9), with which the detection ratio of the AKA was 69%. Possible reasons for failure of visualization of the FIG 3. CT scans obtained in patient 13, a 52-year-old man. A, Coronal multiplanar reconstruction scan shows the radiculomedullary artery (black arrows) arising from the left L1 level and joining the ASA (small white arrows). Both the ascending and descending branches of the ASA are seen. B, Because the radiculomedullary artery (black arrow) is slightly tortuous, the continuity of the vessel is confirmed on the section dorsal to that shown in A.

AJNR: 24, January 2003 MULTI-DETECTOR ROW CT 17 varied from T9 to T11. For these patients, the ASA was visualized from the upper edge of the scanning range; it is thus possible that the AKA was located cranial to the scanning range. Therefore, if the scanning range had been adequate to cover the AKA origin, the detectability of the AKA would have been increased. Although the descending branch of the ASA distal to the junction was shown on the scans of all the patients, the ascending branch of the ASA distal to the junction of the AKA was not shown on the scans of three patients. Because the ascending branch is almost always narrower than the descending branch, we speculate that for these patients, the spatial resolution was not sufficient for detecting the ascending branch, which has a smaller caliber. Conclusion The AKA and descending branch of the ASA can be detected by using multi-detector row CT if they are within the scanning range. CT angiography may be helpful in the evaluation of spinal cord circulation before and after aortic surgery and in the evaluation of spinal cord vascular diseases. FIG 4. CT scan obtained in patient 17, a 25-year-old male patient. Coronal view multiplanar reconstruction scan shows the ASA (small white arrow) as visualized from the top of the scanning range. The radiculomedullary artery is not detected. The upper level of the scanning range is T11 level for this patient. The AKA is expected to arise from a more cranial level. AKA in this study include inadequacy of the scanning range as discussed above, insufficient spatial resolution, and contrast-to-noise ratio. The diameters of the ASA and AKA are almost the same and are reported to be 0.5 to 0.8 mm at the thoracolumbar region (7). Because the ASA was detected for all patients, we think that the spatial resolution and contrast-to-noise ratio were sufficient for the visualization of the AKA. In this study, the segment level of the AKA origin ranged from T10 to L2 and the left side origin was 69%. Although the scanning range was limited, these results were in agreement with those of previous reports, including anatomic (1, 7) and MR angiography results (8, 9). For six patients for whom the AKA was not detected, the upper limit of the scanning range References 1. Tveten L. Spinal cord vascularity: III. the spinal cord arteries in man. Acta Radiol Diagn (Stockh) 1976;17:257 273 2. Rosenthal D. Spinal cord ischemia after abdominal aortic operation: is it preventable? J Vasc Surg 1999;30:391 397 3. Griepp RB, Ergin MA, Galla JD, et al. Looking for the artery of Adamkiewicz: a quest to minimize paraplegia after operations for aneurysms of the descending thoracic and thoracoabdominal aorta. J Thorac Cardiovasc Surg 1996;112:1202 1215 4. Safi HJ, Miller CC III, Carr C, Iliopoulos DC, Dorsay DA, Baldwin JC. Importance of intercostal artery reattachment during thoracoabdominal aortic aneurysm repair. J Vasc Surg 1998;27:58 68 5. Wan IY, Angelini GD, Bryan AJ, Ryder I, Underwood MJ. Prevention of spinal cord ischaemia during descending thoracic and thoracoabdominal aortic surgery. Eur J Cardiothorac Surg 2001;19: 203 213 6. Heinemann MK, Brassel F, Herzog T, Dresler C, Becker H, Borst HG. The role of spinal angiography in operations on the thoracic aorta: myth or reality? Ann Thorac Surg 1998;65:346 351 7. Thron AK. Vascular Anatomy of the Spinal Cord: Neuroradiological Investigations and Clinical Syndromes. New York: Spinger-Verlag; 1988:3 65 8. Yamada N, Okita Y, Minatoya K, et al. Preoperative demonstration of the Adamkiewicz artery by magnetic resonance angiography in patients with descending or thoracoabdominal aortic aneurysms. Eur J Cardiothorac Surg 2000;18:104 111 9. Yamada N, Takamiya M, Kuribayashi S, Okita Y, Minatoya K, Tanaka R. MRA of the Adamkiewicz artery: a preoperative study for thoracic aortic aneurysm. J Comput Assist Tomogr 2000;24:362 368