THE NATURAL FIT. Surgical Technique. Hip Knee Spine Navigation

Similar documents
asterloc Surgical Technique HIP SYSTEM UNDERSTANDING TRADITION, MASTERING INNOVATION Hip Knee Spine Navigation

UNDERSTANDING TRADITION, MASTERING INNOVATION. Surgical Technique

FIRST STEM SPECIFICALLY DESIGNED FOR AMIS. Surgical Technique

FIRST STEM SPECIFICALLY DESIGNED FOR AMIS. Surgical Technique

CC TRIO VERSAFITCUP. Surgical Technique. each to their own. Hip Knee Spine Navigation

Surgical Technique. Hip Knee Spine Navigation

pact SYSTEM Surgical Technique HEMISPHERICAL CEMENTLESS CUP SYSTEM MULTI-HOLE & RIM-HOLE Hip Knee Spine Navigation

EVOLVING OUR HERITAGE, MEETING YOUR NEEDS. Surgical Technique

Cementless Tapered Femoral Stem Surgical technique

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

asterloc Surgical Technique EMBRACING 40 YEARS OF CLINICAL HISTORY Hip Knee Spine Navigation

Cementless Tapered Femoral Stem Surgical technique

Preoperative Planning. The primary objectives of preoperative planning are to:

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Optimum implant geometry

Surgical Technique. Hip System

Surgical technique MkII instrumentation

Progeny Hip Stem. Surgical Protocol and Product Specifications

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

PPS P I N P O S I T I O N I N G S Y S T E M GMK EFFICIENCY VERSION. Hip Knee Spine Navigation

Optimizing function Maximizing survivorship Accelerating recovery

U2 PSA. Revision Knee. Surgical Protocol

HELIOS h i p s y s t e m

Clinical Evaluation Surgical Technique

Taperloc Complete Hip System. Surgical Technique

Metha Short Hip Stem System

Anterior Approach Surgical Technique. Paragon Stem System. enabling people to enjoy life

This surgical technique describes how to perform an anatomic total shoulder arthroplasty implanting a short stem.

MetaFix. Cementless Total Hip Replacement Surgical technique

Revision. Hip Stem. Surgical Protocol

Surgical Technique. *smith&nephew POLARSTEM Cementless Stem System

FLH /11

Bone Conserving Hip Replacement Surgical technique

Approach Patients with Confidence

Bone Preservation Stem

Ovation Hip System. Surgical Technique

ACETABULAR CUP SURGICAL TECHNIQUE

Aesculap Trilliance Triple Tapered Polished Hip Stem

MetaFix. Cementless Total Hip Replacement Surgical technique

AML Hip System. Design Rationale/ Surgical Technique

ANATOMIC SHOULDER ARTHROPLASTY

Cemented femoral stem - type CSC

HIP SYSTEM SURGICAL TECHNIQUE

TaperFill. Surgical Technique

*smith&nephew SL-PLUS

Dual Mobility System Surgical technique

Dual Mobility System Evaluation surgical technique

SURGICAL TECHNIQUE. Alpine Cemented Hip Stem

ZMR Over-the-Junction Instruments for Revision Hip Arthroplasty. Surgical Technique IMAGE TO COME

Zimmer M/L Taper Hip Prosthesis. Surgical Technique

Operating Instruction. Müller Hip Stem

VerSys LD/Fx Cemented and Press-Fit Hip Prostheses. Surgical Technique IMAGE TO COME. Versatile solutions for total and partial hip replacement

operative technique Kent Hip

M.I.S. MAKE IT SMART IN ONE SYSTEM. Surgical Technique. Hip Knee Spine Navigation

Surgical Technique VPLWK QHSKHZ 1$126 1HFN 3UHVHUYLQJ +LS 6WHP 1716-e_NANOS_OPT.indd :27

AVANTEON. Operative Technique & Catalogue Information AVANTEON

MEDACTA UNCONSTRAINED SCREW TECHNOLOGY - REDUCTION SCREWS. Surgical Technique. Hip Knee Spine Navigation

Hype Femoral stems. Surgical technique

Alloclassic Zweymüller Stem

COMPLETE, CONVERTIBLE, INNOVATIVE. Surgical Technique REVERSE SHOULDER ARTHROPLASY

Case Report. Antegrade Femur Lengthening with the PRECICE Limb Lengthening Technology

Approach Patients with Confidence

GENERIC, LOGIC, INTEGRALE TO.H.GB.011/1.0

TaperFit. Cemented Total Hip Replacement Surgical technique

Surgical Technique. *smith&nephew POLARSTEM Cementless and Cemented Stem System

CAUTION Federal law (USA) restricts this device to sale, by or on the order of a physician.

Bi-Polar 22.2mm & 28mm System - Operative technique

CORAIL HIP SYSTEM SURGICAL TECHNIQUE

Integra. Titan Modular Shoulder System, 2.5

Distal Cut First Femoral Preparation

Cementless femoral stem type SF

Efficacy Innovation ABG II. Brochure. Surgical Protocol. Cemented Stem

Surgical Technique. Cup System

This publication is not intended for distribution in the USA.

Manza Cup HA SURGICAL TECHNIQUE.

Zimmer NexGen MIS Tibial Component. Cemented Surgical Technique IMAGE TO COME

Scan Bi-Polar 22/28. Operative Technique

AUTOBLOQUANTE AUTOBLOQUANTE. Product Rationale Surgical Technique

Surgical Technique. SL-PLUS Cementless Femoral Hip System

RESTORATION MODULAR. Surgical Protocol REVISION HIP SYSTEM

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

Absolut TM Cemented Stem. Surgical Technique

Surgical Technique r5.indd 1 12/8/10 10:36 AM

Merete BioBall The Innovative Hip Endoprosthesis Head Adapter System

LUMBAR POSTERIOR MINIMALLY INVASIVE SYSTEM. Surgical Technique

REVERSE SHOULDER ARTHROPLASTY

RESTORATION MODULAR. Surgical Technique REVISION HIP SYSTEM

Trinity. Advanced Bearing Acetabular System Surgical technique

Surgical Technique. DISCLOSURE: This device is not approved for sale in the U.S.A. Customer Service:

ONE SYSTEM, MULTIPLE OPTIONS. Surgical Technique. Hip Knee Spine Navigation

Orthopedic Bone Nail System - Distal Femoral Nail Surgical Technique Manual

Restoration Modular. Revision Hip System Surgical Protocol

S U R G I C A L T E C H N I Q U E

SURGICAL TECHNIQUE. Entrada Hip Stem

FLH183 04/08. Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom. Tel. +44 (0) Fax: +44 (0)

PATIENT MATCHED TECHNOLOGY IN KNEE REPLACEMENT

RESTORATION MODULAR. Surgical Protocol REVISION HIP SYSTEM

Extramedullary Tibial Preparation

Transcription:

THE NATURAL FIT Surgical Technique Hip Knee Spine Navigation

MiniMAX Surgical Technique Hip Knee Spine Navigation INTRODUCTION The MiniMAX TM is a cementless anatomic stem available in 9 right sizes and 9 left sizes. The anatomical design results in a 9 anteversion of the neck and a 5 curvature on the distal tip to follow the contours of the femoral canal. Size by size the head center and the volume of the prosthesis are designed to restore anatomy and provide optimal fit and fill. Carefully read the instructions for use and if you have any questions concerning product compatibility please contact your Medacta representative. MiniMAX TM CAUTION Federal law (USA) restricts this device to sale distribution and use by or on the order of a physician. 2

INDEX 1 INDICATIONS 2 CONTRAINDICATIONS 3 SPECIAL CONSIDERATIONS 4 PREOPERATIVE PLANNING 5 SURGICAL APPROACH 6 FEMORAL NECK OSTEOTOMY 7 FEMORAL PREPARATION 8 TRIALING 9 FINAL IMPLANTS 10 IMPLANT NOMENCLATURE 4 4 4 5 5 5 6 7 8 10 3

MiniMAX Surgical Technique Hip Knee Spine Navigation 1 INDICATIONS The MiniMAX stem is designed for cementless use in total or partial hip arthroplasty in primary or revision surgery. Hip Replacement is indicated in the following cases: Severely painful and/or disabled joint as a result of arthrosis, traumatic arthritis, rheumatoid polyarthritis or congenital hip dysplasia; Avascular necrosis of the femoral head; Acute traumatic fracture of the femoral head or neck; Failure of previous hip surgery: joint reconstruction, internal fixation, arthrodesis, hemiarthroplasty, surface replacement arthroplasty, or total hip replacement. 2 CONTRAINDICATIONS Total or partial hip replacement is contraindicated in the following cases: Acute, systemic or chronic infection; Skeletal immaturity; Muscular, neurological or vascular deficiency of the affected limb; Bone condition that may compromise the stability of the implant; Pathologies that may compromise the functionality of the implant in any way. Mental or neuromuscular disorders may create an unacceptable risk to the patient and can be a source of postoperative complications. It is the surgeon s responsibility to ensure that the patient has no known allergy to the materials used. 3 SPECIAL CONSIDERATIONS The quality of the cancellous bone and the integrity of the cortical bone in the metaphyseal femur have to be considered for a successful implantation of the stem. Since MiniMAX stems are designed to reproduce the anatomical anteversion of the natural femur, it is important to take into account this aspect (especially with dysplastic hips) to ensure that correct reconstruction is possible. 4

4 PREOPERATIVE PLANNING Careful preoperative planning is essential. It will help the surgeon to pre-select the femoral implant size in order to restore an architecture corresponding to the operated patient's anatomy. In addition, using the set of X-ray templates to the scale of 1.15:1 (with an X-ray of the same magnification), it may be possible to determine: The implant size, that must ensure the best metaphyseal fill with the shoulder resting on the infero-lateral part of the greater trochanter; The level of the neck resection, at about 60 with respect to the femoral axis; The neck length; Appropriate femoral head center. NOTICE: the final implant will be selected intra-operatively, because of possible discrepancies between actual conditions and templating. 5 SURGICAL APPROACH The choice of surgical approach is at discretion of the surgeon. The instrumentation has been developed for any approach. A specific instrumentation for the anterior approach is available upon request (for further information see the AMIS dedicated surgical technique). 6 FEMORAL NECK OSTEOTOMY The level of the neck cut is determined during preoperative planning using the X-Ray templates. The femoral neck resection should be planned in accordance with the anatomy of the patient. The suggested resection angle for this implant is 60 to the diaphyseal axis of the femur. The resection is performed with an oscillating saw, taking care to maintain the planned neck resection. The femoral head is removed using an extractor. 60 5

MiniMAX Surgical Technique Hip Knee Spine Navigation 7 FEMORAL PREPARATION To access to the medullary canal, the thigh is held in the position providing the best exposure of the dyaphyseal axis, depending on the selected approach. Create access to the femoral canal using the smallest broach or with the chisel. Remove the bone so that the spongiosa of the greater trochanter does not interfere with the broaches. Assemble the broach on the manual broach handle. Both left and right broaches are available. Make sure the correct one is used. Femoral anatomies vary with individual parameters. However, a frequently chosen and normally valid entry point is the piriformis fossa. Aim the individual instrument toward the femoral axis, starting from the piriformis fossa and carefully follow the canal without applying excessive stress on the femoral bone during the preparation. The MiniMAX is an anatomical stem that will find its way naturally in the femur reproducing the natural anteversion of the femur. The chisel should not determine the antetorsion. A neck anteversion of 9 should be taken into account during the positioning of the cup. Pronounced cup anteversion may result in a less stable artificial joint. For an anterior approach, do not use the chisel because of the possibility of entering the femur with a curved path. Use a curette from bottom to top to clear the lateral proximal metaphysis. NOTICE: in varus hips, correct entry point to the medullary canal and reproduction of the longitudinal axis of the femur can be adequately obtained by reaming the medial part of the greater trochanter. The MiniMAX implant has a neck length that increases with the size. To allow a correct trial reduction, all broaches are endowed with a toothless raise, such that when the trial neck is assembled, the correct neck length is reproduced. The raise is different for each size and must be above the femoral cut. The broaches must be inserted at optimum level determined by the neck cut being flush with the level of the last tooth. WARNING Never force impaction when the broach is blocked in the diaphysis. Raise Level of cut Use the smallest broach to begin broaching of the proximal femur. Broaches of increasing size are introduced until optimal metaphyseal filling is achieved. Ensure proper alignment and antetorsion are achieved. 6 The final broach should be rotationally stable to assure perfect stability of the implant.

8 TRIALING Once the femoral broach shows a satisfactory rotational stability, position a trial neck, left or right depending on the side being operated on. To lock the trial necks to the broach press onto the socket; to unlock pull the neck. NOTICE: the head impactor must be used only for head impaction and reduction and not for the correction of the acetabular shell position. To remove a trial head, simply pull it. TIP If the trial head is difficult to remove from the trial neck, moisten the trial head - trial neck assembly. Twist and gently pull the trial head to extract it. Trial heads of different diameters and sizes are available to perform the trial reductions. A trial head is fitted to the trial neck by pushing it onto the taper. TIP To make head insertion easier, moisten it before insertion. After checking and testing mobility, joint stability and lower limb length, remove the broach. TIP An extraction system can be used if the broach is difficult to remove. First screw the broach extractor to the broach. Depending on the selected approach, assemble the screwed stem extractor M8 to the broach extractor. Pull out the broach. Anterior approach Posterior approach After placement of the trial or final acetabular component, the trial reduction is performed with the help of the head impactor. 7

MiniMAX Surgical Technique Hip Knee Spine Navigation 9 FINAL IMPLANTS Insert the final prosthesis into place. The final prosthesis corresponds to the size of the last trial broach and to the side (left or right) corresponding to the operated leg. WARNING Take care not to damage the neck's micro-thread while placing the final implant. The stem is moved down to the limit corresponding to the test and matching the end of the macrostructures. Carefully perform final impaction using the dedicated impactor. CAUTION The metal head sizes XL (for Ø 28 mm and Ø 32 mm) and XXL (for Ø 28 mm, Ø 32 mm and Ø 36 mm) have a collar. This may decrease the Range of Motion in comparison to smaller sizes. Always perform trial reduction with the chosen head. The stem taper must be thoroughly cleaned before impacting the prosthetic head. Place the final head of the chosen size in position and secure it using the head impactor. CAUTION Under no circumstances should the implant anteversion be changed at this stage. WARNING Never strike the femoral head directly with a metal mallet or hammer. Use only the plastic head impactor provided for this purpose. NOTICE: for further details about ceramic femoral heads, please refer to the instructions for use for ceramic femoral heads. WARNING Never force impaction when the stem is blocked in the diaphysis. OPTION After impaction, if the final stem needs to be repositioned, a stem repositioner is available. This repositioner can be used with any hip approach, including the AMIS technique. A further trial reduction can then be performed to determine the final head size. 8

Screw Assemble the stem repositioner by unscrewing the screw with the 3.5mm screwdriver to open the plastic clamps. Then, assemble it to the implanted stem until this is firmly seated between the plastic clamps and re-tighten the screw. The metal body should be positioned on the medial side of the stem. Depending on the selected approach, screw the threaded stem extractor M8 onto the stem repositioner (30 hole is suggested for the AMIS approach). Pull out the stem. 30 0 9

MiniMAX Surgical Technique Hip Knee Spine Navigation 10 IMPLANT NOMENCLATURE MiniMAX Left Size Right 01.13.100L 0 01.13.100R 01.13.101L 1 01.13.101R 01.13.102L 2 01.13.102R 01.13.103L 3 01.13.103R 01.13.104L 4 01.13.104R 01.13.105L 5 01.13.105R 01.13.106L 6 01.13.106R 01.13.107L 7 01.13.107R 01.13.108L 8 01.13.108R Anteversion: 9 127 CCD angle: 127 Distal curvature: 5 10

HEADS Diameter (mm) Size CoCr MectaCer BIOLOX delta Ø 22 S 01.25.124 - Ø 22 M 01.25.123 - Ø 28 S 01.25.011 01.29.201 Ø 28 M 01.25.012 01.29.202 Ø 28 L 01.25.013 01.29.203 Ø 28 XL 01.25.014 - Ø 28 XXL 01.25.015 - Ø 32 S 01.25.021 01.29.204 Ø 32 M 01.25.022 01.29.205 Ø 32 L 01.25.023 01.29.206 Ø 32 XL 01.25.024 01.29.207 Ø 32 XXL 01.25.025 - Ø 36 S 01.25.030 01.29.208 Ø 36 M 01.25.031 01.29.209 Ø 36 L 01.25.032 01.29.210 Ø 36 XL 01.25.033 01.29.211 Ø 36 XXL 01.25.034 - Ø 40 S - 01.29.212 Ø 40 M - 01.29.213 Ø 40 L - 01.29.214 Ø 40 XL - 01.29.215 Ø 40 XXL - - MectaCer BIOLOX Option system'' Head Diameter (mm) Reference Ø 28 01.29.230H Ø 32 01.29.231H Ø 36 01.29.232H Ø 40 01.29.233H Sleeve Size Reference S 01.29.240A M 01.29.241A L 01.29.242A XL 01.29.243A II Specific for revision cases. NOTE FOR STERILIZATION The instruments are not sterile upon delivery. Instruments must be cleaned before use and sterilized in an autoclave respecting the US regulations, directives where applicable, and following the manufacturers instructions for use of the autoclave. For detailed instructions please refer to the document Recommendations for cleaning decontamination and sterilization of Medacta International reusable orthopaedic devices available at www.medacta.com. 11

REDEFINING BETTER IN ORTHOPAEDICS AND NEUROSURGERY MEDACTA.COM Medacta International SA Strada Regina - 6874 Castel San Pietro - Switzerland Phone +41 91 696 60 60 - Fax +41 91 696 60 66 info@medacta.ch Find your local dealer at: medacta.com/locations All trademarks and registered trademarks are the property of their respective owners. MiniMAX TM Surgical Technique ref: 99.13MM.12US rev.00 Last update: August 2017