MICRONAIL. Intramedullary Distal Radius System SURGICAL TECHNIQUE

Similar documents
Surgical Technique Guide

AcUMEDr. FoREARM ROD SYSTEM

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

PHALINX. Hammertoe Fixation SURGICAL TECHNIQUE

Surgical Technique. Forearm Fracture Solutions

Wright Medical Technology, Inc Cherry Road Memphis, TN

The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1)

CHARLOTTE. 3.0 and 4.3 Multi-Use Compression Screws SURGIC A L T ECHNIQUE

2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

Instrument and Implant for wrist fracture

Contents. Chapter 1 4 Chapter Chapter Chapter Chapter 5 15

Visualize, stabilize, mobilize. Wristore * Distal Radius Fracture Fixator Abbreviated Surgical Technique

Acu-Loc Wrist Plating System. Surgical Technique

Orthopedic Bone Nail System - Distal Femoral Nail Surgical Technique Manual

Conventus CAGE PH Surgical Techniques

Technique Guide. VA-Locking Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis.

Modular Ulnar Head surgical technique. Transforming Extremities

Acu-Loc Wrist Spanning Plate System. Surgical Technique

CHARLOTTE. Snap-Off Screws SURGICAL TECHNIQUE

CSS. Cannulated Screw System SURGICAL TECHNIQUE

2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

CANNULINK. Intraossous Fixation System SURGICAL TECHNIQUE

Zimmer ITST Intertrochanteric/ Subtrochanteric Fixation System. Abbreviated Surgical Technique

2.4 mm Variable Angle LCP Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis.

WINSTA-R. Distal Radius System

Surgical Technique Carpal Fusion

Zimmer Small Fragment Universal Locking System. Surgical Technique

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

Distal Radius Plate 2.4/2.7 dorsal and volar

Technique Guide. Adjustable Distal Radius Fixator. Part of the Synthes External Fixation Systems.

2.4 mm LCP Volar Column Distal Radius Plates. Part of the 2.4 mm LCP Distal Radius System.

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

CHARLOTTE. Compression Staple SURGIC A L T ECHNIQUE

Acu-Loc 2 Wrist Plating System

3. Insert Tocar Sleeves Insert the NCB tissue protection sleeve assembly 1.6 to 10mm through a skin incision (Fig. 38).

DARCO. Bow 2 Plate SURGIC AL TECHNIQUE

Long Volar Plates for Diaphyseal-Metaphyseal Radius Fractures LCP. Dia-Meta Volar Distal Radius Plates. Surgical Technique

Integra. DigiFuse Cannulated Intramedullary Fusion System SURGICAL TECHNIQUE

Surgical Technique. Olecranon Locking Plate

Forearm Fracture Solutions. Surgical Technique

System. Humeral Nail. Surgical Technique

Variable Angle LCP Volar Rim Distal Radius Plate 2.4. For fragment-specific fracture fixation with variable angle locking technology.

Surgical Technique. Wrist Plating System

Surgical Technique. Calcaneal Locking Plate

3. PATIENT POSITIONING & FRACTURE REDUCTION 3 8. DISTAL GUIDED LOCKING FOR PROXIMAL NAIL PROXIMAL LOCKING FOR LONG NAIL 13

Biomet Large Cannulated Screw System

FUSEFORCE. Hand Fixation System SURGICAL TECHNIQUE

Olecranon Osteotomy Nail. For simple fractures and osteotomies of the olecranon.

Volar Distal Radius Plating System Surgical Technique

Integra. Silicone PIP Implant SURGICAL TECHNIQUE

Ascension. Silicone MCP surgical technique. surgical technique Ascension Silicone MCP

Surgical Technique. Fibula Rod System

Double Engine Orthopedic Bone Nail System Universal Humeral Nail

Distal Ulnar Locking Plate

Fibula Rod System. Lateral Malleolus Fracture Indications:

Surgical Technique. Targeter Systems Overview

Technique Guide. LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

Surgical Technique. Distal Humerus Locking Plate

Surgical Technique. CONQUEST FN Femoral Neck Fracture System

Open reduction; plate fixation 1 Principles

SURGICAL TECHNIQUE GUIDE

Surgical Technique. Clavicle Locking Plate

Wrist Fixation System

Chapter 4: Forearm 4.3 Forearm shaft fractures, transverse (12-D/4)

Technique Guide. 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system.

Surgical Technique. Proximal Humerus Locking Plate

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments. Part of the 3.5 mm LCP Percutaneous Instrument System.

Distal Radius and Distal Ulna Plates System Self-Tapping Spherical Locking Screw Self-Tapping Conical Locking Screw Cortex Screw

E-CENTRIX. Ulnar Head Replacement SURGICAL TECHNIQUE

WINSTA-C. Clavicle Plating System

Locking Radial Head Plates

LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius.

STRENGTH FROM WITHIN. Surgical Technique for Representatives

Integra. Spider and Mini Spider Limited Wrist Fusion System SURGICAL TECHNIQUE

Acu-Loc 2 Wrist Plating System. Surgical Technique

LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

LCP Distal Humerus Plates

Foot & Ankle. Smart Toe II. Intramedullary Implant. Operative Technique. Foot & Ankle

VariAx TM Distal Radius Locking Plate System

Volar Distal Radius Plating System Surgical Technique

CHARLOTTE. 7.0 Multi-Use Compression Screw System SURGICAL TECHNIQUE

Implantable K-wire SURGIC A L T ECHNIQUE

100 Interpace Parkway Parsippany, NJ

LMH. Minimal Bone Resection. Lesser Metatarsal Head Implant. Thin, low-profile design for minimal bone resection

RAYHACK Kienbock Radial Shortening System

Technique Guide. 3.5 mm LCP Periarticular Proximal Humerus Plate. Part of the Synthes locking compression plate (LCP) system.

AcUMEDr. Locking Proximal Humeral Plate. PoLARUSr PHPt

PediLoc 3.5mm and 4.5mm Contour Femur Plate Surgical Technique

SALVATION 3Di. Plating System SURGICAL TECHNIQUE

STS. Subtalar Spacer System SURGICAL TECHNIQUE

Surgical Technique. Distal Radius and Foot

ORTHOLOC 3Di. Foot Reconstruction System Midfoot Fusion Plate SURGICAL TECHNIQUE

ORTHOFLEX. Silicone Hammertoe Implant SURGICAL TECHNIQUE

SURGICAL TECHNIQUE GUIDE

DARCO. LPS Plate SURGICAL TECHNIQUE

Merete PlantarMAX Lapidus Plate Surgical Technique. Description of Plate

Surgical Technique. DISCLOSURE: This device is not approved for sale in the U.S.A. Customer Service:

Transcription:

MICRONAIL II Intramedullary Distal Radius System SURGICAL TECHNIQUE

Contents Introduction 3 4 Chapter 1 5 Chapter 2 6 Appendix A 18 Appendix B 19 Surgeon Design Team Introduction Product Information Surgical Technique Ordering Information Instrumentation Proper surgical procedures and techniques are the responsibility of the medical professional. The following guidelines are furnished for information purposes only. Each surgeon must evaluate the appropriateness of the procedures based on his or her personal medical training and experience. Prior to use of the system, the surgeon should refer to the product package insert for complete warnings, precautions, indications, contraindications and adverse effects. Package inserts are also available by contacting Wright Medical.

Surgeon Design Team Surgeon Design Team The MICRONAIL II Intramedullary Distal Radius System was developed in conjunction with: Mark Warburton, MD John Capo, MD Virak Tan, MD Matthew Putnam, MD Joseph Slade III, MD MICRONAIL Intramedullary Distal Radius System 3

MICONAIL II Intramedullary Distal Radius System Introduction Patient Selection The MICRONAIL II Intramedullary Distal Radius System is primarily designed for minimally-invasive fixation of extra-articular fractures and simple intraarticular fractures of the distal radius. It is particularly useful for treatment of patients who have failed non-operative treatment and malunion of such fractures. 4 MICRONAIL Intramedullary Distal Radius System

Product Information chapter 1 Features and Benefits Titanium alloy (Ti-6Al-4V ELI) Universal configuration for left and right wrists Available in five anatomical sizes Zero profile A 2.0mm hole located in the proximal body allows for temporary fixation using a K-wire during fracture reduction. Three 2.5mm fixed-angle locking screws buttress the subchondral plate and secure the distal fracture fragment(s) to the nail. The distal screws are anatomically configured to approximate the radial inclination while the volar-dorsal angle divergence provides stable, three-point fixation. The distal screw heads are completely recessed below the surface of the nail. Two 2.7mm self-tapping, bi-cortical, proximal screws resist shortening and angulation of the distal fracture fragment. The screws are placed through the proximal body of the nail while the low-profile head rests on the dorsal surface of the bone. Chapter 1 Product Information 5

Surgical Technique chapter 2 Initial Reduction Achieve provisional angular (dorsal/volar) reduction prior to initiating the MICRONAIL II implant procedure. To stabilize reduction, temporarily place a 0.062 K-wire (P/N 59410625) dorsal to volar Figures 1, 2 along the dorsal ulnar cortex of the radius as needed. Figure 3 The K-wire is inserted at an acute angle aiming toward the volar ulnar cortex of the proximal fragment and away from the insertion path of the broach. The wire maintains the first plane of reduction (volar tilt restoration). The second plane of reduction (radial height) will be obtained later in the procedure by distraction. FIGURE 1 Optional K-wire FIGURE 2 FIGURE 3 Keep K-wire out of broaching path 6 Chapter 2 Surgical Technique

Surgical Exposure Make a 2-3cm longitudinal incision centered over the radial styloid. Bluntly dissect through the subcutaneous tissue. Mobilize any branches of the radial sensory nerve and retract from the surgical field. Dissect down to the periosteum between the 1st and 2nd dorsal extensor compartments. Figures 4, 5 Expose the cortex by elevating a rectangular flap of periosteum from the first to second compartment. Figure 6 2-3cm incision FIGURE 4 FIGURE 5 Altered material reprinted with permission from The Journal of Bone and Joint Surgery, Inc. FIGURE 6 Chapter 2 Surgical Technique 7

Cortical Window Insert a K-wire (P/N 59410625) 4mm proximal to the radioscaphoid joint line and centered (dorsal to volar) in the radial styloid just radial to the second compartment Figures 7, 8 Use fluoroscopy to verify position (both AP and lateral). Figures 9, 10 NOTE Entering the styloid too proximal can lead to improper nail position and reduce subchondral support. Insert the 6.1mm Cannulated Starter Drill (P/N 26949468) through the Starter Drill / K-wire Guide (P/N 26949462) and over the K-wire to create a cortical window. If necessary, use a small rongeur to enlarge the hole proximally to allow for easier broach insertion. Cortical window 1st dorsal compartment tendons 2nd dorsal compartment tendons FIGURE 7 ~ 25-30 (from long axis of radial shaft) NOTE Guide position relative to subchondral bone FIGURE 8 FIGURE 9 Proper guide wire position on lateral view. FIGURE 10 Proper guide wire position on AP view. 8 Chapter 2 Surgical Technique

Canal Entry Create a bolster using two folded towels and place beneath the wrist. Deviate the wrist ulnarly to gain access to the medullary canal. Insert the Starter Awl (P/N 26949471) through the cortical window and into the medullary canal until the shoulder of the awl is countersunk beneath the cortical bone. Figures 11, 12 Keep the tip of the starter awl against the radial cortex. Figure 13 FIGURE 11 FIGURE 12 FIGURE 13 Chapter 2 Surgical Technique 9

Broaching Broach in a manner similar to a total hip or shoulder arthroplasty. Gently tap the Broaches with a small mallet as needed to advance or remove the broaches. Figure 14 Alternatively, the smooth trials can be used to broach the canal in osteoporotic bones. Correct broaching is critical to avoid implant rotation. Broach down the axis of the radius staying parallel with the dorsal surface and close to the radial cortex creating a rectangular path for the Implant. Be sure to medialize the broach. This will allow the distal aspect of the MICRONAIL implant to lie within the medullary cavity of the radius. Removal of cancellous bone may be necessary. Figure 15 Verify proper broach placement by inserting a K-wire through the distal hole of the Broaches. The K-wire should lie just below the subchondral bone. Figure 16 Sizing Broach using progressively larger Broaches (or Trials) until the Broach does not spin within the medullary canal. Sizing is done with the Trials to determine the appropriate sized implant. The correct size is achieved when the Trial does not spin within the canal with 2-finger pressure. Select appropriately-sized Implant. Down-sizing the Implant is recommended rather than over-stuffing the canal. Choose the largest implant that inserts easily. Obtain a lateral X-Ray before final implantation to ensure volar tilt and radial height is maintained. Subchondral support FIGURE 14 FIGURE 15 FIGURE 16 Insert guide wire 2-3mm proximal to articular surface. 10 Chapter 2 Surgical Technique

Assemble Components A B Attach Core Body to Outrigger Attach Proximal Targeting Guide C D Attach Implant Attach Threaded Handle to Outrigger Assembly Chapter 2 Surgical Technique 11

Rotation Correct broaching and implant positioning is critical to avoid rotation. The implant has locked, fixed angle screws that diverge distally and proper intramedullary placement can be observed on a lateral radiograph view. Similar to the broach, the proximal targeting guide should be parallel to the dorsal surface of the distal forearm. Figure 17 Implant Insertion Insert the Implant into the meduallary canal using the outrigger assemlbly. Position the Outrigger so the proximal guide is parallel to the dorsal surface of the radius to maintain proper rotation. Verify proper implant placement by inserting a 2.0mm drill bit (P/N 26948211) through the most distal hole of the Outrigger. This can be done by hand. The drill bit should lie within 3mm of the subchrondral bone of the distal radius. Figure 18 Also, verify in lateral view that reduction has been maintained. Subchondral support FIGURE 17 FIGURE 18 12 Chapter 1 Description of Section

Buttress Screw Placement Insert the Drill Guide (P/N26948210) through the core body until it seats directly on the implant. This is the most distal buttress screw and should be inserted first. Drilling the distal Buttress Screws is typically done by hand and not power. The Drill Bit (P/N 26948211) is coated and the Drill Guide (P/N26948210) is marked with the the screw lengths. Align the Drill Bit s coating to the Drill Guide increments for accurate screw length. Insert under fluoro to confirm the screw length does not penetrate the DRUJ. NOTE Subtracting 2mm from the measured length of the distal screws will avoid potential penetration into the DRUJ. Confirm proper screw placement under fluoro. The most common screw lengths are 20-24mm. Use the Screwdriver Handle (P/N 44112009) and self-retaining Cruciform Screwdriver (P/N 26948112) to remove the appropriate size 2.5mm Buttress Screw (P/N 59412516 through 28) from the screw caddy. A firm stop will be felt when the Buttress Screw is locked into the implant. Figure19 FIGURE 19 FIGURE 20 Chapter 2 Surgical Technique 13

Buttress Screw Placement If position and length of the most distal Buttress Screw is satisfactory, insert the next two buttress screws. Insert the Tissue Protector (P/N 26948209) and the Drill Guide (P/N26948210) in the appropriate holes. The Tissue Protector must be seated directly on the bone in order to obtain accurate screw length. The next two Buttress Screws are typically 2mm less than the first. Example: If the most distal Buttress Screw is 22mm, then the remaining two Buttress Screws are 20mm. Care should be taken to retract any soft tissues. If necessary, the initial incision can be enlarged. Figure 20 The Buttress Screws should be positioned in a divergent fashion and the distal fragment should now be securely captured. Figures 21, 22 FIGURE 21 FIGURE 22 14 Chapter 1 Description of Section

Proximal Exposure Using the Proximal Targeting Guide as a template, mark a 2-3cm line on the skin of the patient that spans the two screw holes. Temporarily remove the Proximal Targeting Guide and make the skin incision. Figure23 Retract the extensor tendons and bluntly dissect the underlying soft tissue to the surface of the radius. Dissection will be just ulnar to the muscles of the first compartment. Proximal Targeting The Proximal Targeting Guide is re-attached to the Outrigger after the dissection is complete. Figure 24 FIGURE 23 FIGURE 24 Chapter 2 Surgical Technique 15

Final Reduction Prior to securing the implant proximally, final reduction can be performed. Any provisional K-wires that remain should be removed.use flouro to check radial height. Adjust as necessary to maintain alignment. This is the second plane of reduction for the radius fracture. If necessary, temporarily maintain reduction by inserting a K-wire through one of the K-wire holes on the Proximal Targeting Guide. Figure 25 Cortical Screw Placement Insert the Tissue Protector (P/N 26948209) into the Proximal Targeting Guide until it rests on the cortical bone surface. Drill the hole for the Cortical Screw. Figure 26 FIGURE 25 FIGURE 26 16 Chapter 2 Surgical Technique

Using power, drill through the first (dorsal) cortex and through the implant until the drill bit reaches the second (volar) cortex. Determine screw length by aligning the end of the Drill Bit s black coating with the appropriate number on the Drill Guide (P/N 26948210). Add 2mm as necessary. Complete the bicortical hole by drilling through the second (volar) cortex. Figure 27 Remove the Drill Guide (P/N 26948210) and insert the appropriate size screw and tighten until the head is flush with the bone. Use the proximal screwdriver (P/N 26948224) and tighten until laser mark is flush with top of tissue protector. Repeat these steps for the remaining Cortical Screw. Cortical Screws are typically 12-14 mm long. Closure Remove the Outrigger Assembly and provisional K-wire. Take the forearm and wrist through a full ROM to ensure that there are no penetrating screws in the DRUJ or radiocarpal joint and check overall fracture stability. Irrigate the surgical site and perform standard skin closure. The cortical entry site at the radial styloid does not require any type of closure. Postoperative Treatment Place the wrist in a splint for 7-10 days. Start finger motion immediately post-op. At the first post-op visit, remove the splint and progress therapy. FIGURE 27 FIGURE 28 Final lateral view of MICRONAIL System FIGURE 29 Final AP view of MICRONAIL System Chapter 2 Surgical Technique 17

Appendix A Ordering Information MICRONAIL Intramedullary Distal Radius System 5943B/2 CATALOG # PART DESCRIPTION 59410001 SIZE 1 DISTAL RADIUS IMPLANT 59410002 SIZE 2 DISTAL RADIUS IMPLANT 59410003 SIZE 3 DISTAL RADIUS IMPLANT 59410004 SIZE 4 DISTAL RADIUS IMPLANT 59410005 SIZE XL DISTAL RADIUS IMPLANT 59412516 2.5 X 16MM BUTTRESS SCREW 59412518 2.5 X 18MM BUTTRESS SCREW 59412520 2.5 X 20MM BUTTRESS SCREW 59412522 2.5 X 22MM BUTTRESS SCREW 59412524 2.5 X 24MM BUTTRESS SCREW 59412526 2.5 X 26MM BUTTRESS SCREW 59412528 2.5 X 28MM BUTTRESS SCREW 59412710 2.7 X 10MM CORTICAL SCREW 59412712 2.7 X 12MM CORTICAL SCREW 59412714 2.7 X 14MM CORTICAL SCREW 59412716 2.7 X 16MM CORTICAL SCREW 59412718 2.7 X 18MM CORTICAL SCREW 59412720 2.7 X 20MM CORTICAL SCREW 59410625.062 X 5 K-WIRE, STERILE 26948211 DRILL BIT 2.0MM 26948200 OUTRIGGER CORE BODY 26948201 OUTRIGGER DISTAL GUIDE RIGHT 26948202 OUTRIGGER DISTAL GUIDE LEFT 26948203 OUTRIGGER PROXIMAL GUIDE SZ 1 26948204 OUTRIGGER PROXIMAL GUIDE SZ 2 26948205 OUTRIGGER PROXIMAL GUIDE SZ 3 26948206 OUTRIGGER PROXIMAL GUIDE SZ 4 26948207 OUTRIGGER PROXIMAL GUIDE SZ XL 26948208 OUTRIGGER HANDLE 26948209 TISSUE PROTECTOR 26948210 DRILL GUIDE 2.0MM 26949462 STARTER DRILL/K-WIRE GUIDE 26948112 SCREWDRIVER 26948224 PROXIMAL SCREWDRIVER 26948114 OUTRIGGER WRENCH 26949474 2.7MM CORTICAL SCREW TAP 26949468 6.1MM CANNULATED STARTER DRILL 44112009 CANNULATED SCREWDRIVER HANDLE 26949471 STARTER AWL 26948115 TRIAL SIZE 1 26948116 TRIAL SIZE 2 26948117 TRIAL SIZE 3 26948118 TRIAL SIZE 4 26948119 TRIAL SIZE XL 26949451 BROACH SIZE 1 26949452 BROACH SIZE 2 26949453 BROACH SIZE 3 26949454 BROACH SIZE 4 26948120 BROACH SIZE XL 18 Appendix A

Appendix B Instrumentation and Implants Tray 1 Drill - Broach - Trial Awl Broach Trial Starter Drill Starter K-Wire/Drill Guide Drill Guide and Drill Bit Tray 2 Implants - Screws Handle Implants Proximal Guide Outrigger Tissue Protector Universal Wrench Screw Caddy Appendix B 19

Wright Medical Technology, Inc. 1023 Cherry Road Memphis, TN 38117 800 238 7117 901 867 9971 www.wmt.com Wright Medical EMEA Atlas Arena, Australia Building Hoogoorddreef 7 1101 BA Amsterdam the Netherlands 011 31 20 565 9060 Trademarks and Registered marks of Wright Medical Technology, Inc. 2014 Wright Medical Technology, Inc. All Rights Reserved. 010465A_June-15-2014