IORT with mobile linacs: the Italian experience

Similar documents
Special techniques overview : IORT

Commissioning and Quality Assurance in IOeRT

Amendment No. 2. Item No. 2 (Rfx/ Event number )

Multilayer Gafchromic film detectors for breast skin dose determination in vivo

Shielding Design Basis and its Calculation of High Energy Medical Linac Installed in Bangladesh Atomic Energy Commission, Bangladesh

Calibration of Radiation Instruments Used in Radiation Protection and Radiotherapy in Malaysia

CALCULATION OF BACKSCATTER FACTORS FOR LOW ENERGY X-RAYS USING THE TOPAS MONTE CARLO CODE

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

A preliminary clinic dosimetry study for synchrotron radiation therapy at SSRF

Use of Bubble Detectors to Characterize Neutron Dose Distribution in a Radiotherapy Treatment Room used for IMRT treatments

Assessment of Dosimetric Functions of An Equinox 100 Telecobalt Machine

Production and dosimetry of simultaneous therapeutic photons and electrons beam by linear accelerator: a monte carlo study

Technology Challenges of Commercial Medical Electron Accelerators

A comparison of dose distributions measured with two types of radiochromic film dosimeter MD55 and EBT for proton beam of energy 175 MeV

A new geometric and mechanical verification device for medical LINACs

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

In vivo dosimetry and shielding disk alignment verification by EBT3 GAFCHROMIC film in breast IOERT treatment

Two-Dimensional Thermoluminescence Dosimetry System for Proton Beam Quality Assurance

Calibration of dosimeters for small mega voltage photon fields at ARPANSA

Out-of-field doses of CyberKnife in stereotactic radiotherapy of prostate cancer patients

Disclosure. Outline. Machine Overview. I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past.

IMRT QUESTIONNAIRE. Address: Physicist: Research Associate: Dosimetrist: Responsible Radiation Oncologist(s)

DOSIMETRIC COMPARISION FOR RADIATION QUALITY IN HIGH ENERGY PHOTON BEAMS

Slide 1. Slide 2. Slide 3. Introduction of INTRABEAM IORT. Disclosure. Contents. I have nothing to disclose.

Neutron Interactions Part 2. Neutron shielding. Neutron shielding. George Starkschall, Ph.D. Department of Radiation Physics

S. Derreumaux (IRSN) Accidents in radiation therapy in France: causes, consequences and lessons learned

Assessment of variation of wedge factor with depth, field size and SSD for Neptun 10PC Linac in Mashhad Imam Reza Hospital

Introduction. Chapter 15 Radiation Protection. Advisory bodies. Regulatory bodies. Main Principles of Radiation Protection

Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties

Present state and issues in IORT Physics

Practical Reference Dosimetry Course April 2015 PRDC Program, at a glance. Version 1.0. Day 1 Day 2 Day 3 Day 4

Quality assurance in external radiotherapy

PROCEDURE FOR ABSORBED DOSE TO WATER DETERMINATION IN HIGH ENERGY PHOTON AND ELECTRON BEAMS BY FERROUS SULPHATE DOSIMETER AT INMRI-ENEA

CHARACTERIZATION OF THE ELECTRON BEAM RADIATION FIELD BY CHEMICAL DOSIMETRY

SOMATOM Drive System Owner Manual Dosimetry and imaging performance report

Introduction. Measurement of Secondary Radiation for Electron and Proton Accelerators. Introduction - Photons. Introduction - Neutrons.

Small field diode dosimetry

Diode calibration for dose determination in total body irradiation

Measurement of Dose to Implanted Cardiac Devices in Radiotherapy Patients

Limits of Precision and Accuracy of Radiation Delivery Systems

Report to the 18 th Meeting of the CCRI(I), May 2007 Recent Activities in Measurement Standards and Dosimetry at METAS,

INSTRUMENTS. Personal alarm dosimeter 120 Survey meters 122 Beta secondary standard 123

Protection of the contralateral breast during radiation therapy for breast cancer


ARCCHECK: COMPREHENSIVE EVALUATION OF THE DIODE ARRAY PHANTOM - RULES OF THUMB FOR PHANTOM USE FOR QA. By Vibha Chaswal, Ph.D.

Topics covered 7/21/2014. Radiation Dosimetry for Proton Therapy

Joint ICTP/IAEA Advanced School on Dosimetry in Diagnostic Radiology and its Clinical Implementation May 2009

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

Douglas J. Simpkin, Ph.D. Aurora St. Luke s Medical Center Milwaukee, Wisconsin. www.

Neutron dose evaluation in radiotherapy

Semiflex 3D. Always perfectly oriented. 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry

Monte Carlo simulation of 192 Ir radioactive source in a phantom designed for brachytherapy dosimetry and source position evaluation.

9.7 Dosimetry Study on A p-n Junction Semiconductor Detector

Sordina IORT Technologies S.p.A. Liac The mobile electron accelerator that revolutionizes IORT

Semiflex 3D. Always perfectly oriented. 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry

Dependence of the thermoluminescent high-temperature ratio (HTR) of LiF:Mg,Ti detectors on proton energy and dose

D DAVID PUBLISHING. Uncertainties of in vivo Dosimetry Using Semiconductors. I. Introduction. 2. Methodology

LONG TERM STABILITY OF THE PERFORMANCE OF A CLINICAL LINEAR ACCELERATOR AND Z-SCORE ASSESSEMENT FOR ABSORBED DOSE TO WATER QUANTITY

Results of dose control and measurement plans applied for SPEAR3 commissioning year (FY04)

INTRODUCTION. Material and Methods

IAEA-CN THE ESTRO-EQUAL RESULTS FOR PHOTON AND ELECTRON BEAMS CHECKS IN EUROPEAN RADIOTHERAPY BEAMS*

Comparison of microlion liquid filled ionisation chamber with Semiflex and Pinpoint air filled chambers

Leila E. A. Nichol Royal Surrey County Hospital

SHIELDING TECHNIQUES FOR CURRENT RADIATION THERAPY MODALITIES

How accurately can we measure dose clinically? Accurate clinical dosimetry. Dosimetric accuracy requirement

TLD as a tool for remote verification of output for radiotherapy beams: 25 years of experience

Non-target dose from radiotherapy: Magnitude, Evaluation, and Impact. Stephen F. Kry, Ph.D., D.ABR.

Radiation Dosimetry at the BNL High Flux Beam Reactor and Medical Research Reactor

Mania Aspradakis John Byrne Hugo Palmans John Conway Jim Warrington Karen Rosser Simon Duane

Canadian Partnership for Quality Radiotherapy. Technical Quality Control Guidelines for Gamma Knife Radiosurgery. A guidance document on behalf of:

PGY-1. Resident Review Session Schedule

Dosimetric study of 2D ion chamber array matrix for the modern radiotherapy treatment verification

Outline. Chapter 12 Treatment Planning Combination of Beams. Opposing pairs of beams. Combination of beams. Opposing pairs of beams

EXPERIMENTAL RESULTS IN PERCENTAGE DEPTH DOSE (PDD) DETERMINATION AT THE EXTENDED DISTANCES *

DOSE MEASUREMENTS IN TELETHERAPY USING THERMOLUMINESCENT DOSIMETERS

The Journey of Cyberknife Commissioning

Radioactive sources in brachytherapy

AN ABSTRACT OF THE THESIS OF. Leanna R. Eller for the degree of Master of Science in Radiation Health Physics

Radiation protection in proton therapy

Radiation Safety Characteristics of the NOMAD Portable X-ray System

Commissioning and Radiobiology of the INTRABEAM System

Radiochromic film dosimetry in water phantoms

Measurement Guided Dose Reconstruction (MGDR) Transitioning VMAT QA from phantom to patient geometry

Verification of treatment planning system parameters in tomotherapy using EBT Radiochromic Film

Electron therapy Class 3: Clinical procedures

Quality assurance and credentialing requirements for sites using inverse planned IMRT Techniques

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

Module Rhodes

Advanced film dosimetry for a UK brachytherapy audit

ABSTRACTS FOR RADIOTHERAPY STANDARDS USERS MEETING. 5 th June 2007

Absolute Dosimetry. Versatile solid and water phantoms. Introduction Introduction Introduction Introtro Intro Intro

10 Years of Safe Operation at the Canadian Light Source A Radiation Safety Perspective

Calibration of TLD700:LiF for Clinical Radiotherapy Beam Modalities & Verification of a High Dose Rate Brachytherapy Treatment Planning System

Assessment of radiation dose to the chest wall and lung of the patients with breast cancer under electron beam therapy

When worker safety is mission critical. Thermo Scientific EPD TruDose Electronic Dosimeter

Dollars and Sense: Are We Overshielding Imaging Facilities? Part 2

Verification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging

Activity report from JCOG physics group

Table of Contents. Introduction 3. Background 4

Zakithi Msimang SAAPMB/SARPA 2011

Transcription:

IORT with mobile linacs: the Italian experience G. Tosi, M. Ciocca lntroduction At the beginning of 1999 a mobile Linac (Novac 7, manufactured by Hitesys, Aprilia, Italy) able to produce electron beams in the nominal energy range 4.5-9 MeV became available at the European Institute of Oncology, Milano, Italy for being employed in traditional operating rooms, especially for the IORT of early breast cancer patients, alternative to conventional postsurgical radiotherapy. Until april 30 th 2004, 899 early breast cancer patients and 25 patients with other type of tumours have been treated wilh this linac, without any type of accident. Due to the increase of the demand of this type of radiation treatment, at the beginning of February 2004 a second unit came into operation (LIAC manufactured by Info &Tech, Roma) able to produce electron beams in the nominal energy range 4-10 MeV. In this paper, the main physical and dosimetrical problems related with the clinical use of these linacs will be treated. Mechanical and physical characteristics of mobile linacs Both Novac 7 and LIAC are specifically designed for being employed in a conventional operating room (s. Fig. 1). They are mounted in a motorised structure that can be easily displaced inside the operating room thanks to a caster installed in the base, and pushed very slowly towards the operating table and the patient, so as to be easily positioned with great accuracy in the treatment position. Novac 7 is equipped with three sets of four plexiglas applicators each, plane (0 ) and bevelled (22.5 and 45 ), whose characteristics are shown in Table I and Fig. 2. The available applicators of LIAC are listed in Table II. Fig. 1. The mobile linacs Novac 7 and LI4C with an applicator mounted on the radiating head ready for the treatment in the operating room. TABLE I Available applicators for Novac 7 Applicator s diameter (cm) SSD (cm) Bevel angles 4 80 0-22 5-45 5 80 0-22 5-45 6 80 0-22.5-45 8 80 0º 22.5-45 10 100 0-22.5º 45º Medical Physics Department European Institute of Oncology Milano (Italy) (0 ) (45 ) Fig. 2. Plane (0 ) and bevelled (45 ) applicators. 50

Oncología, 2004; 27 (6):350-354 TABLE II Available applicators for LIAC Applicator s diameter (cm) SSD (cm) Bevel angles 3 60 0º - 15-30 - 45 4 60 0º - 15-30 - 45 5 50 0º - 15-30 - 45 6 60 0º - 15-30 - 45 7 60 0-15 - 30-45 8 60 0º - 15-30 - 45 10 60 0º - 15-30 - 45 12 60 0º - 15-30 - 45 According to the manufacturer, Novac 7 can deliver electron beams of 4 nominal energies: 3, 5, 7 and 9 MeV; the emission of electrons is pulsed, with a frequency of 5 Hz, a pulse duration very short (4 µs) and a very high dose/pulse (1.9 8.5 cgy/pulse, depending on energy and applicator s diameter). In order to reduce the production of Bremsstrahlung, and consequently to reduce the radiation protection problems, no scattering foil is present aloog the path of the electrons from the exit window to the patient; the enlargement of the beam s section is due only to the geometrical divergence and to the rather large nominal SSD (80 cm for the applicators with a diameter 8 cm and 100 cm for the applicators with a diameter=10 cm). On the other side, LIAC can deliver electron beams of 4 nominal energies: 4, 6, 8 and 10 MeV; the emission of electrons is pulsed, with a frequency of 10 Hz (in the clinical modality, 20 Hz in the physical modality), a short pulse duration (10 µs) and a very high dose/pulse (0.2 4.5 cgy/pulse, depending on energy and applicator s diameter) and dose-rate (1.5-27 Gy/min, depending on energy). In order to reduce the length of the applicators, LIAC is equipped with a scattering foil (80 µm brass), that increases the amount of braking radiation. However, Bremsstrahlung is produced also as a consequence of the interaction of the electron beams with the patient s tissues. For this reason, before using both Novac 7 and LIAC in the operating rooms (placed at the second floor of the building) a very rigorous acceptance test was planned. For safety reason, all the evaluations and measurements were performed at the underground level of the building, inside a bunker where a 25 MeV conventional linac was installed and operating. The main parameters checked both during the acceptance test and in the course of the quality control program are the following: User s interface Stability (constancy of the emission) Actual energy of the beams Beams profiles (symmetry and flatness) Isodose curves in water Dose (Gy/MU-Gy/pulse) and dose rate Stray radiation (leakage radiation from the radiating head Bremsstrahlung scattered radiation) Mechanical characteristics and reliability, connection to the earth, warnings, etc. The evaluation of the actual energy E p, 0 of the beams was based on the measurement in a water phantom and using Fig. 3. Experimental set-up for the determination of the percentage depth dose curves (PDD), of the practical range (R p ) and of the actual energy (E p,0 of the electron beams. small diodes (s. Fig. 3) of the depth dose curves along the beam s central axis, the determination of the practical range R p and the use of the following range-energy relationship: where: C 1 =0.22MeV C 2 = 1.98 MeV cm -1 C 3 = 0.0025 MeV cm -2 E p,0 = C 1 + C 2 R p + C 3 R p 2 As shown in Table 3, the actual energies of the beams are significantly different than those declared by the manulactu- TABLE III Nominal and actual energies of the electron beams Energies declared by the manufacturers and actual energies E p,0 Novac 7 LIAC 3 MeV 4.5 MeV 4 MeV 4.85 MeV 5 MeV 5.2 MeV 6 MeV 5.95 MeV 7 MeV 6.5 MeV 8 MeV 7.95 MeV 9 MeV 7.8 MeV 10 MeV 9.95 MeV 51

G. Tosi y M. Ciocca Fig. 4. Depth dose curves in water for Novac 7. From links to right, nominal energies of 3, 5, 7 and 9 MeV. In abscissa: depth in mm; in ordinate: percentage depth dose, normalised to the maximum. rer for Novac 7, and very near to the declared values for LIAC. The depth dose curves for the electron beams generated by Novac 7 are illustrated in Fig. 4. Fig. 5. Profile at the depth of maximum dose of an electron beam (nominal energy 9 MeV, plane applicator Φ 80 mm) - Novac 7. The measurement of the beams profiles at the depth of maximum dose was made using small diodes; both the flatness and the symmetry are very good, as is shown in Fig. 5. Radiation protection problems In the following tables the depth of maximum and of 80% of the dose in water for plane applicators of Novac 7 and LIAC are reported. TABLE IV Depth of maximum and of 80% dose in water for Novac 7 Nominal energy Depth of maximum Depth of 80% (MeV) dose (mm) (mm) 3 7 13 5 10 15 7 12 20 9 15 24 Fig. 6. Sources of stray radiation in the use of Novac 7 (a similar situation occurs for LIAC). TABLE V Depth of maximum and of 80% dose in water for LIAC Nominal energy Depth of maximum Depth of 80% (MeV) dose (mm) (mm) 4 8 13 6 9 18 8 12 23 10 13 29 For the absolute calibration of the dose, a set of Fricke dosimeters calibrated, delivered and evaluated at the ENEA Laboratories of Casaccia (Roma) were used. For the check of the dose that is performed in a solid phantom before each treatment, a flat ionisation chamber (Markus or Roos type) calibrated against the Fricke dosimeters and GafChromic films, calibrated in conventional electron beams are used. The stray radiation generated by the two mobile linacs is made up by four different components (s. Fig. 6): 1. Iow energy radiation, scattered into the environment by the patient or by any object present along the beam s path. 2. Ieakage from the radiating head. 3. electrons emerging from the applicator s walls (PMMA, 5 mm thick) and scattered at various angles. 4. Bremsstrahlung generated by the interaction of the electron beam with the patient or any other object present along its path. In order to evaluate both the intensity and the quality of such environmental radiation, some different detectors have been employed, namely: a ionization chamber Victoreen mod. 450 P. a radiation GM monitor Rados RDS-120 Universal Survey Meter, equipped also with a beta-ray probe. a radiation monitor (proportional counter) FAG Contamat FHT 111M. 52

Oncología, 2004; 27 (6):350-354 The measurements of this stray radiation were made at the maximum nominal energies of the linacs (9 MeV and 10 MeV respectively), and irradiating a PMMA phantom (30 cm x 30 cm x 10 cm) using the plane applicators having a diameter of 10 cm and working therefore at a SSD = 100 cm for Novac 7 and 60 cm for LIAC. Two main conclusion could immediately be drawn: the components 1. and 3. (low energy radiation and electrons emerging from the applicator s walls) can be completely absorbed by 5 mm Pb. the intensity of the Bremsstrahlung strongly depends on the angle, being maximum in the direction of the beam (angle=0 ) and minimum in the opposite direction (angle=180 ), according to the second column of Table 7. also the energy, evaluated through the measurement of the attenuation in lead depends on the angle, as can be seen in the third column of the same table, where the TVL (Tenth Value Layers) are listed. Moreover, in order to evaluate the attenuation produced by the floor and by the ceiling of the operating rooms (25 cm TABLE VI Angular dependence of the intensity of the Bremsstrahlung Angle % intensity TVL (mm Pb) 0 100 50 30 14 45 45 8 40 60 3 35 90 1.3 32 135 0.2 30 180 0.04 30 concrete), the attenuation properties of concrete were evaluated, and TVL of 26 cm at 0 and of 20 cm at 180 were found. In order to design the mobile shields to be used during the functioning of the linac in a conventional operating room, measurements of dose-rate in air at various distances and with different thickness of lead were pertormed. The results for Novac 7, expressed in µgy/100 pulses are reported in Table VII. The following working loads were estimated: 400 treatments/operating room/year 30Gy/treatment A dose constraint of 1 msv/year/operator (surgeons, anaesthetist, radiotherapist, medical physicist, etc.) was taken into account; the same dose constraint was established for the people living in the underlying and overlaying spaces. On the basis of the above mentioned evaluations, 4 mobile barriers mounted on casters and having the following characteristics were designed and built: height : 150 cm. width : 120 cm. thickness : 15 mm Pb from the floor to an height of 50 cm. 10 mm Pb from 50 cm to 100 cm. 5 mm Pb from 100 cm to 150 cm. cover : 10 mm PMMA on the face of the barrier oriented towards the patient. total weight: 230 kg In order to absorb the Bremsstrahlung emerging from the patient during the treatment, moreover, beam stoppers mounted on casters and having the following characteristics were designed and built: TABLE VII Dose in air (expressed in µgy/100 pulses) at different angles and for different lead thickness Angle 0 30 45º 60 90 135 180 Distance (cm) 130 140 150 150 130 165 300 mm Pb µgy/100 pulses 0 160 221 556 540 360 19 3.2 5 95.5 12.6 6.6 2.5 1.2 0.2 0.1 10 70.2 9.4 4.7 1.7 0.8 15 59.2 6.4 3.5 1.2 0.6 20 43.1 5.2 2.8 0.9 0.4 25 34.5 4.2 2 0.8 0.2 30 28.2 3.2 1.5 0.6 35 23.1 2.5 1.2 0.4 40 16.1 2.0 1.0 0.22 45 13.7 1.6 0.6 50 11.5 1.1 0.2 55 9.1 0,9 60 7.5 0.2 70 4.6 80 2.5 100 1.0 120 0.4 140 0.2 53

G. Tosi y M. Ciocca Fig. 8. Positioning of the applicator. Fig. 7. Schematic layout of the operating room and of the control room, where the control panel (CP) of the linac is installed Clinical procedure. width : 45 cm length : 60cm thickness : 150 mm Pb weight : 330 kg These beam stoppers are interlocked with the linacs, so as to make the emission of radiation impossible if the they are not placed under the operating table during the emission of the beam. A schematic layout of the operating room and of the control room, where the control panel (CP) of the linacs is installed is shown in Fig. 7. After the surgeon has removed the tumour, a technician, assisted by a medical physicist, brings the linac nearby the operating table and helps the radiotherapist and the surgeon to put the applicator (that is hard-docked to the radiating head of the linac) in the treatment position (s. Fig. 8). In the meantime, a series of light- and acoustic warnings is activated; immediately after, the technician places the mobile barriers in the right positions around the operating table and all the personnel (surgeon, anaesthetist, radiotherapist, medical physicist, technician, nurses of the operating room, etc.) leaves the operating room and remains in the control room, from which the patient can constantly be controlled via the window of the door of the operating room and a telecamera. The radiotherapist prescribes the energy and the dose and the medical physicist starts the irradiation. The personnel classified as exposed worker due to its usual activities (radiotherapist, technician, medical physicist) wears its usual personal dosimeters. The other personnel, classified as not exposed (surgeon, anaesthetist, nurse, etc.) was monitored with a personal dosimeter only for the first three months, in order to check the adequacy of the classification. All the dosimeters indicated a value of the effective dose <50 µsv, thus confirming the adequacy both of the classification and of the barriers. Conclusions Up to april 30 th o 2004, 889 early breast cancer patients and 25 other types of tumours have been treated, with very good results as regards both the long-term local control of the tumour and the absence of unwanted sideeffects. In vivo dosimetry was also performed, using calibrated radiochromic films (s. Radiotherapy and Oncology 2003; 69:285-9) and/or Mosfet dosimeters. An agreement within±5% between the prescribed dose and the actually delivered dose was found. As far as radiation protection is concerned, during the first month of activity, and afterwards with a quarterly frequency, environmental film and TLD-dosimeters were placed inside the adjacent, underlying and overlaying spaces; all the results were always very near to the natural background; even dosimeters placed on the inner face of the walls of the operating rooms revealed doses very low, <6 msv/y. During 5 years of employ of Novac 7, only in 7 planned cases it was impossible to deliver the treatment due to faults of the equipment; a stop of nearly one month was necessary in 2003 for the change of the electron gun. After 3 months of employ, no fault has occurred with LIAC. These results allow to conclude that the described mobile linacs are very reliable and can be sabely used for intraoperative radiotherapy. In early breast cancer patients this treatment technique, when indicated, can represent a valid alternative to post-surgical external radiotherapy. If adequate radiation protection measures are adopted, no risk exists for the involved personnel. 54