RADIOLOGY. Head & Neck IMAGING. Iranian Journal of

Similar documents
The Effect of X Ray Vertical Angulation on Radiographic Assessment of Alveolar Bone Loss

Periodontal Disease. Radiology of Periodontal Disease. Periodontal Disease. The Role of Radiology in Assessment of Periodontal Disease

The Effect of Bite Registration on the Reproducibility of Parallel Periapical Radiographs Obtained with Two Month Intervals

Root Proximity Characteristics and Type of Alveolar Bone Loss: A Case-control Study

골내결손부에서의치주조직재생 : 증례보고

Esthetic Crown Lengthening for Upper Anterior Teeth: Indications and Surgical Techniques

Radiographic Evaluation of Bone Formation and Density Changes after Mandibular Third Molar Extraction: A 6 Month Follow up

Bone Levels - From Hypothesis To Facts

A Clinical Evaluation of Anatomic Features of Gingiva in Dental Students in Tabriz, Iran

Esthetic Crown Lengthening for Upper Anterior Teeth: Indications and Surgical Techniques

Introduction. Clinical Periodontal Examination 11/1/16

Evidence-based decision making in periodontal tooth prognosis

Classifications for Gingival Recession: A Mini Review

Radiology. & supporting structures. Lec. 14 Common diseases of teeth Dr. Areej

The influence of sensor size and orientation on image quality in intra-oral periapical radiography

All Dentistry is Cosmetic Betsy Bakeman, DDS Arkansas State Dental Association

Research Article Are Panoramic Radiographs Reliable to Diagnose Mild Alveolar Bone Resorption?

Intrusion of Incisors to Facilitate Restoration: The Impact on the Periodontium

RESEARCH REVIEW. Gingival recession: a proposal for a new classification ISSN :

Advanced Probing Techniques

FRACTURES AND LUXATIONS OF PERMANENT TEETH

In vitro cone beam computed tomography imaging of periodontal bone

The dentogingival junction to the

1B Getting Ready for Instrumentation: Mathematical Principles and Anatomic Descriptors

Radiology in Periodontics

Fundamental & Preventive Curvatures of Teeth and Tooth Development. Lecture Three Chapter 15 Continued; Chapter 6 (parts) Dr. Margaret L.

ELIMINATE POCKETS. Periodontal pocket is the consequence of periodontal infection But also a major risk factor for the further progression of disease

Diagnostic accuracy of conventional radiography and digital radiography in detecting of root fractures (invitro study)

International Journal of Health Sciences and Research ISSN:

Topographie Classification of Deformities of the Alveolar

Case Study. Case # 1 Author: Dr. Suheil Boutros (USA) 2013 Zimmer Dental, Inc. All rights reserved. 6557, Rev. 03/13.

Large Dentigerous Cyst

Purpose: To assess the long term survival of sites treated by GTR.

Controlling Tissue Contours with a Prosthetically Driven Approach to Implant Dentistry

Evaluation of a Digital Measurement Tool to Estimate Working Length in Endodontics

Alveolar bone development before the placement

Prosthetic Options in Implant Dentistry. Hakimeh Siadat, DDS, MSc Associate Professor

Management of osseous defects in aggressive periodontitis: A report of four cases using different techniques

Monday Morning Pearls of Practice by Bobby Baig

Working together as a team, the periodontist

Evaluation of Guided Tissue Regeneration Following Third Molar Extraction by Bone Scintigraphy Using Tc99m-MDP

Periapical radiography and cone beam computed tomography for assessment of the periapical bone defect 1 week and 12 months after root-end resection

The Treatment of Gingival Recession Associated with Deep Corono-Radicular Abrasions (CEJ step) a Case Series

Surgical reconstruction of lost papilla around implant with a modified technique: A case report

Efficacy of a bioactive alloplast, in the treatment of human periodontal osseous defects-a clinical study

Replacement of a congenitally missing lateral incisor in the maxillary anterior aesthetic zone using a narrow diameter implant: A case report

DENTAL RADIOLOGY Identify basic facts and terms of radiology, to include fundamentals. with 70% accuracy.

Course File 243 DDS Physics of Diagnostic Radiology and Oral and Maxillofacial Radiology

Chapter 2. Material and methods

Unusual transmigration of canines report of two cases in a family

Contemporary Implant Dentistry

MODIFIED SINGLE ROLL FLAP APPROACH FOR SIMULTANEOUS IMPLANT PLACEMENT AND GINGIVAL AUGMENTATION

6610 NE 181st Street, Suite #1, Kenmore, WA

Rehabilitating a Compromised Site for Restoring Form, Function and Esthetics- A Case Report

Intraoral radiographic techniques Introduction There are three main types of intraoral radiographs: Periapical radiograph Bitewing radiograph

A modified device for intraoral radiography to assess the distal osseous defects of mandibular second molar after impacted third molar surgery

International Journal of Current Medical and Pharmaceutical Research

Surgical Uprighting Is a Successful Procedure for Management of Impacted Mandibular Second Molars

Assessment of the relationship between the maxillary molars and adjacent structures using cone beam computed tomography

Digital Imaging from a new perspective

Principles of Periodontal flap surgery. Dr.maryam khosravi

Hemisection as an Alternative Treatment for Decayed Multirooted Abutment: A Case Report

EFFECTIVE DATE: 04/24/14 REVISED DATE: 04/23/15, 04/28/16, 06/22/17, 06/28/18 POLICY NUMBER: CATEGORY: Dental

Minimally invasive techniques for periodontal regeneration

Evidence-based decision-making in endodontics

Orthodontic space opening during adolescence is

Comparison between different papillary recession classification systems

Extraction with Immediate Implant Placement and Ridge Preservation in the Posterior

Analysis of the embrasure dimensions between maxillary central incisors in relation to the topography of the interdental papilla

高雄醫學大學 口腔醫學院 口腔病理影像科 牙科 X 光影像判讀 教學範例

The diagnosis of periodontal disease is greatly facilitated

Orthodontic Case Report

Periapical Radiography

14/09/15. Assessment of Periodontal Disease. Outline. Why is Periodontal assessment needed? The Basics of Periodontal assessment

CIC Edizioni Internazionali

Treatment Options for the Compromised Tooth

Advance Dental Simulation Module on Crown Preparation

Dr. Muhannad Abdulrhman Muhammed Halwani, Rakan Saed Safar Al Thobaiti and Abdallah Ali M Asker

IMPACTED CANINES. Unfortunately, this important tooth is the second most common tooth to be impacted after third molars

The Association between Embrasure Morphology and Central Papilla Recession: A Noninvasive Assessment Method. Li-Ching Chang, DDS, MS

GuidedService. The ultimate guide for precise implantations

Corresponding author: *Heba Wageh Abo-Zaed Elsaed. DOI: / Page

Dental Research Journal

Subject: Clinical Crown Lengthening Guideline #: Publish Date: 03/15/2018 Status: Revised Last Review Date: 02/06/2018

3D Accuitomo XYZ Slice View Tomograph. Super High-Resolution Images of Region of Interest

Alveolar ridge preservation techniques

MANAGEMENT OF ATROPHIC ANTERIOR MAXILLA USING RIDGE SPLIT TECHNIQUE, IMMEDIATE IMPLANTATION AND TEMPORIZATION

EVALUATION OF MODIFIED EXTRAORAL TECHNIQUE IN ZYGOMATIC ARCH EXAMINATION

Extraoral Radiology October 10th, 2008

PERIODONTAL CASE PRESENTATION - 1

Diagnosis and epidemiology of periodontal osseous lesions

Intraoral Imaging. Chapter 41. Copyright 2018, Elsevier Inc. All Rights Reserved. 1

Evaluation of proximity of the floor of the maxillary. Zanco J. Med. Sci., Vol. 16, No. (2), 2012

You know you would like to stop swearing at the computer after each shot. Troubleshooting oral radiography

Educational Training Document

Masking Buccal Plate Remodeling in the Esthetic Zone with Connective Tissue Grafts: Concepts and Techniques with Immediate Implants

Evaluation of cortical bone thickness of mandible with cone beam computed tomography for orthodontic mini implant installation

University of Groningen

3 Dimensional Diagnosis Unravelling Prognosis of Multiple Impacted Teeth A Case Report

CASE REPORT. CBCT-Assisted Treatment of the Failing Long Span Bridge with Staged and Immediate Load Implant Restoration

Transcription:

Head & Neck IMAGING Iran J Radiol. 2012;9(2):83-87. DOI: 10.5812/iranjradiol.7732 Iranian Journal of RADIOLOGY RADIOLOGYwww.iranjradiol.com Determination of Vertical Interproximal Bone Loss Topography: Correlation Between Indirect Digital Radiographic Measurement and Clinical Measurement Farzad Esmaeli 1, Adileh Shirmohammadi 2*, Masoumeh Faramarzie 2, Nader Abolfazli 2, Hossein Rasouli 2, Saied Fallahi 2 1 Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran 2 Department of Periodontics, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran ARTICLE INFO Article type: Original Article Article history: Received: 05 Feb 2011 Revised: 03 Apr 2012 Accepted: 20 Jun 2012 Keywords: Radiography Dental Bone Diseases Topography, Medical ABSTRACT Background: Diagnosis and accuracy in determining the exact location, extent and configuration of bony defects of the jaw are of utmost importance to determine prognosis, treatment planning and long-term preservation of teeth. If relatively accurate diagnosis can be established by radiography, proper treatment planning prior to treatment procedures will be possible. Objectives: The aim of the present study was to assess the correlation between indirect digital radiographic measurements and clinical measurements in determining the topography of interproximal bony defects. Patients and Methods: Twenty interproximal bony defects, preferably in the mandibular and maxillary 5 5 area were selected and radiographed using the parallel periapical technique. The radiographs were corrected and digitized on a computer using Linear Measurement software; then the three parameters of the base of defect (BD), alveolar crest (AC) and cementoenamel junction (CEJ) were determined using a software. Subsequent to radiographic measurements, clinical measurements were carried out meticulously during flap procedures. Then linear measurements were carried out using a periodontal probe to determine the defect depth and its mesiodistal width. Then the amount of correlation between these two measurements was assessed by Pearson's correlation coefficient. Results: The correlation between clinical and radiographic measurements in defect depth determination, in the evaluation of defect angle and in determination of defect width were 88%, 98% and 90%, respectively. Conclusions: Indirect digital radiographic technique can be used to diagnose intra-osseous defects, providing a better opportunity to treat bony defects. Copyright c 2012, Tehran University of Medical Sciences and Iranian Society of Radiology. Published by Kowsar Corp. All rights reserved. Implication for health policy/practice/research/medical education: The possibility of precise determination of intraosseous bony defects of the jaw by plain radiography could be a very feasible paraclinical study that may improve treatment planning and prognosis determination of teeth preservation procedures in periodontics. Please cite this paper as: Esmaeli F, Shirmohammadi A, Faramarzie M, Abolfazli N, Rasouli, H, Fallahi, S. Determination of Vertical Interproximal Bone Loss Topography: Correlation Between Indirect Digital Radiographic Measurement and Clinical Measurement. 2012. Iran J Radiol. 2012;9(2):83-7. DOI: 10.5812/iranjradiol.7732 * Corresponding author: Adileh Shirmohammadi, Department of Periodontics, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran. Tel: +98-4113355965, Fax: +98-4113346977, E-mail: shirmohamadia@yahoo.com DOI: 10.5812/iranjradiol.7732 Copyright c 2012, Tehran University of Medical Sciences and Iranian Society of Radiology. Published by Kowsar Corp. All rights reserved. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Esmaeli F et al. Indirect Digital Radiography in Determining Vertical Bone Loss 1. Background In periodontal diseases, the bone destruction pattern is divided into horizontal (even) and oblique (vertical/angular) defects. In the vertical pattern, bone destruction does not proceed in a symmetrical pattern. The severity of bone destruction varies in different parts around the tooth, which explains why the alveolar crest does not correspond to cemento-enamel junction (CEJ) and is not parallel to it (1). This bone destruction pattern gives rise to bony defects in which the base of the defect is located more apical to the alveolar crest (2). Diagnosis and accuracy in determining the exact location, extent and configuration of bony defects are of utmost importance to determine prognosis, to plan treatment and to preserve the teeth in the long run (3). Because determination of the depth and to some extent, the width of bony defects is an important parameter in the prognosis of treatment, it is important to accurately measure these two parameters on radiographs to develop a correct and appropriate treatment plan (4). Recently, digital radiography has attracted a lot of attention in determining the depth, width and topography of bony defects and progression of the defect since loss of bone density and height should be evaluated using an automated instrument to diagnose periodontal lesions and assess the treatment success (4). There are only a limited number of studies which have evaluated radiographic views of bony periodontal defects with inconclusive results (5). Pepelassi et al. (2000) evaluated the potential of conventional radiographic techniques in the diagnosis of intra-osseous periodontal defects in comparison with intra-operative evaluations and concluded that: 1. Radiographic techniques have limited capacity to determine and diagnose bony defects. 2. The accuracy of PA radiographs depends on the number of wall defects, the depth and bucco-lingual width and the location in the jaws. 3. It is difficult to characterize small and shallow defects on radiographs (6). Kelin et al. evaluated the depth and width of bony defects as a diagnostic factor and changes in defect width as a determinant of periodontal healing in intra-osseous defects treated with GTR 6 and 24 months after surgery. In that study, subjects with intra-osseous defects were selected and treated with eptfe (expanded polytetrafluoroethylene, a non-absorbable membrane). A computer was used to determine the depth, width and angulations of the defect. The bonefill had been preserved 24 months after surgery. They also concluded that the depth of the intra-osseous component is a more appropriate diagnostic parameter compared to the angulations of the defect (4). 2. Objectives The aim of the present study was to evaluate the diagnostic value of indirect digital radiography (with the parallel technique) in determining the topography of periodontal bony defects and compare the results with real measurements. 3. Patients and Methods 3.1. Patient Selection In this cross-sectional study, 20 interproximal bony defects were selected in patients who had undergone phase one periodontal therapy and were candidates for periodontal surgery. The inclusion criteria included no contraindications for periodontal surgery and exposure to X-rays. Patients with shallow palate or elevated floor of the mouth were excluded. Defects in the 5 5 area were preferably selected. Pre-operative periapical radiographs were provided using the parallel technique in an XCP film holder (Dentsply, Rinn). One radiograph was provided for each interproximal defect. In order to determine the vertical and horizontal difference between the central ray and orthoradial projection, two pieces of orthodontic wire with a specific length were placed at a premeasured distance from each other on the mandibular side of the film holder. Then horizontal magnification was calculated by dividing the wire length on the radiograph by its real length. Vertical magnification was calculated by dividing the distance between the wires on the radiograph by their real distance. The radiographic machine Philips Oralix 655 and Kodak E-speed intra-oral films (Eastmary Kodak) were used in the radiography procedure (56 kvp, 7.5 ma). The radiographs were transferred to a computer using Mustek P3600 A3 PRO Scanner with a resolution of 400 pixels. Imag J (ver. 1.34) software (National Institutes of Health) was used for measurements on a computer. 3.2. Radiographic Examination Linear Measurement T software was used to open the radiographic images and in a manner similar to Photoshop software the following parameters were determined (Figure 1). BD is the most coronal point where periodontal ligament (PDL) continuity is observed. If PDL could not be determined, the point at which the alveolar crest (AC) projection contacted the root surface was selected as the landmark. If both landmarks were present, the first one was designated as BD and the second was designated as AC. If multiple bone contours were visible, the most apical contour contacting the root surface was designated as BD and the most coronal one was designated as AC. CEJ was the fixed coronal reference for these measurements. After CEJ, AC and BD were determined on the screen, the following measurements were carried out: Defect depth = CIJ/BD - CEJ/AC Defect width: Defect width is the distance between the mesial and distal borders of the bony defect, which is the distance between the lateral margin of the defect and the AC on the root surface. 84 Iran J Radiol. 2012;9(2)

Indirect Digital Radiography in Determining Vertical Bone Loss Esmaeli F et al. Defect angle: Defect angle is the angle between the lateral defect wall and the root surface, which is drawn in the following manner: One wall of the angle extends from CEJ to BD and the other wall extends from BD to the lateral margin of the defect. Radiographic measurements are made after drawing the above-mentioned lines. Subsequent to radiographic measurements, clinical measurements are carried out accurately during flap elevation. Measurements are made after removal of the granulation tissue and before only resective or regenerative surgical treatment. Bony defects not located on proximal surfaces were excluded from the study. At first, vertical defect type (the number of remaining walls) was determined and the following measurements were carried out: Liner measurement: Linear measurement was carried out using a calibrated periodontal probe (PCPUNC-15, Hufriedy) to the nearest 0.5 mm: 1. Depth of the osseous defect: the distance between the alveolar crest and the base of the osseous defect. 2. Mesiodistal width of the osseous defect: the distance between the root surface and the osseous border of the defect in a mesiodistal direction at the level of the bony crest or the distance between the mesial and distal borders of the osseous defect. Accordingly, the minimum dimensions for a defect are: width = 0.5 mm; depth = 0.5 mm. 3. Defect angle: A hydrosol (elastomeric polyvinylsiloxane impression material) impression was taken from the defect. This impression material was injected into the defect after mixing. Caution was exercised not to introduce bubbles into the material. The material was set after 6-7 minutes and then a sharp blade was used to draw an imaginary plane which extended from the alveolar crest to the buccal (or lingual) plate of the proximal tooth. Subsequently, the impression was removed from the defect using an explorer; then, the tips of the two forks of a pair of calipers were placed tangential with the two proximal walls of the impression and fixed. Then, the angle between the lateral wall of the defect and the root surface was determined. In both digital and clinical measurements, a periodontist carried out the measurement procedures three times and the mean of the three measurements was reported as the final value. This technique minimized intrarater error. After clinical and radiographic measurements were completed, the results were compared to evaluate similarities and differences between the methods. These were tested with Pearson s correlation coefficient. All the statistical analyses were performed using SPSS version 15. A P-value under 0.05 was considered statistically significant. 4. Results 4.1. Correlation Between Clinical and Radiographic Measurements in Determining the Defect Depth According to (Figure 2) and Pearson s correlation coefficient, the correlation between radiographic and clinical measurements in determining the defect depth was strong (r-square = 0.88, P < 0.001). 4.2. Correlation Between Clinical and Radiographic Measurements in Determining the Defect Angle According to (Figure 3) and Pearson s correlation coeffi- Figure 1. Radiographic measurements Figure 2. Correlation and regression between clinical and radiographic measurements in determining the defect depth Iran J Radiol. 2012;9(2) 85

Esmaeli F et al. Indirect Digital Radiography in Determining Vertical Bone Loss cient, the correlation between radiographic and clinical measurements in determining defect angle was strong (r-square = 0.98, P < 0.001), demonstrating a strong correlation according to regression equation. 4.3. Correlation Between Clinical and Radiographic Measurements in Determining the Defect Width According to (Figure 4) and Pearson s correlation coefficient, agreement between clinical and radiographic measurements in determining defect width was strong (r-square = 0.90, P < 0.001). Figure 3. Correlation and regression between clinical and radiographic measurements in determining the defect angle 4.4. Correlation Between Clinical and Radiographic Measurements in Determining the Defect Depth, Width and Angle According to (Figure 5), the mean differences between clinical and radiographic measurements of defect angle, depth and width were 1.41, 0.24 and 0.42, respectively. 5. Discussion The results of the present study showed that digitized parallel periapical radiographs have a high level of correlation with clinical measurements. Therefore, the technique can be used to determine prognosis and also for treatment planning in osseous defects of the jaw. In the present study, the differences between radiographic and clinical measurements in relation to defect width and depth were 0.42 and 0.24, respectively, with no statistically significant differences; i.e. radiographic measurement was similar to clinical measurement. The results of the present study regarding width and depth measurements were respectively, consistent and inconsistent with the results of a study carried out by Pepelassi et al. (6) which compared the potential of conventional periapical and panoramic radiographic techniques in the determination and imaging accuracy of intra-osseous lesions compared to evaluations during surgical procedures. They evaluated the presence and measured the dimensions of osseous lesions during flap surgery, measured the distance between the alveolar crest and the lowermost part of the lesion (BD) on radiographs and measured the mesiodistal width of the lesion clinically using a periodontal probe. The results of their study showed that periapical radiographs were three times more efficient than panoramic views in determining the presence of osseous lesions. The results also revealed that the depth of the lesion by the two mentioned radiographic techniques is depicted bigger than the actual lesion size. This controversy might be attributed to the location, the types of teeth and jaw and the greater depth of the defects in the study carried out by Pepelassi et al. The results of the present study in this respect are consistent with those of Kelin et al. (4). They evaluated the depth and width of the lesion as a factor involved in determining prognosis and changes in the width of the lesions as a factor involved in demonstrating repair of osseous lesions treated with GTR, 6 and 24 months after surgery. Periapical radio- 1.6 1.4 1.2 1 0.8 0.6 0.4 0.2 0 1.41 0.24 0.42 D.Angle D.Depth D.Width Figure 4. Correlation and regression between clinical and radiographic measurements in determining the defect width Figure 5. Mean differences between clinical and radiographic measurements of the defect angle, depth and width 86 Iran J Radiol. 2012;9(2)

Indirect Digital Radiography in Determining Vertical Bone Loss Esmaeli F et al. graphs were provided and CEJ-AC and CEJ-BD distances were measured at baseline and 6 and 24 months after surgery using digitized CCD camera and a computer. The results of the study demonstrated statistically significant differences in bone filling and bridging of wall defects, 6 and 24 months after surgery compared to conventional treatment modalities. The authors concluded that the radiographic analysis used in the study is a precise method for the evaluation of intra-osseous lesions and treatment results and measurements are close to actual dimensions. In a study carried out by Wolf et al. (7), selected digital modifications (filters, scatter, structure) in radiographic images did not result in more reproducible or more valid results for measuring bone resorption in interproximal lesions compared with un-modified digital radiographs. Although the radiographic values were lower than the clinical values in the present study, the differences were not statistically significant, with a strong correlation between radiographic and clinical values. Periodontal diseases result in endosteal resorption, which produces radiolucencies; however, bone resorption does not produce a uniformly recognizable view. Extra- and intra-oral radiographic techniques are used to record changes. Radiographs are two-dimensional representations of a three-dimensional structure. Therefore, the image is not an accurate one and bone resorption on the radiograph is depicted smaller than the actual lesion size. Therefore, measurements of bone resorption on radiographs are not accurate to diagnose osseous lesions. In 1980, Goodson et al. used a computer as an aid in the linear evaluation of bone resorption (8). Given the technological advances and introduction of digital radiographic technique, it has extensively been used in medicine and its use in dentistry is rapidly on the rise. Digital radiographic technique is carried out in direct and indirect procedures. The main advantage of digitized radiographs is the ability to manipulate and enhance the quality of images using various software programs (5). In most cases, enhancement, which is carried out by a modified contrast, optimized illuminosity and decreased image noise, results in a visually-optimized image. In fact, image enhancement produces an optimized version of the primary image (9). However, a visually-optimized image does not necessarily result in better interpretation of the image. Manipulation of a digital image does not increase data; it only makes the structures better visible by condensing the data available. In such cases the possible decrease in the data available is a consideration. This higher coordination is suitable for low-quality images which have low contrast, or are overexposed or underexposed. Various software programs are available for the manipulation and linear evaluation of digitized radiographs (10). Various studies using different software programs have yielded differing and sometimes contradictory results. In the present study, linear evaluation during surgery and also on conventional periapical radiographs were carried out on 0.5-mm intervals; however, linear evaluations on digitized radiographs were carried out by manipulation on a computer at 0.01-mm intervals, which might be the main reason for the higher value of digitized radiographs compared to conventional periapical radiographs. One of the limitations of the present study was the number of samples and the absence of evaluation of the above-mentioned method in determining the topography of various interproximal osseous lesions (one-wall, two-wall and three-wall defects). Therefore, it is suggested that further studies should be carried out with larger sample sizes for evaluating various types of periodontal osseous defects. The results indicate that digital enhancement can result in an increased ability to diagnose intra-osseous defects, paving the way for a more appropriate decision-making process to treat intra-osseous lesions more properly. Acknowledgments Authors Contribution Financial Disclosure Funding/Support References 1. Ellegaard B. Bone grafts in periodontal attachment procedures. J Clin Periodontol. 1976;3(5):1-54. 2. Prichard JF. The diagnosis and management of vertical bony defects. J Periodontol. 1983;54(1):29-35. 3. Papapanou PN, Wennstrom JL. The angular bony defect as indicator of further alveolar bone loss. J Clin Periodontol. 1991;18(5):317-22. 4. Klein F, Kim TS, Hassfeld S, Staehle HJ, Reitmeir P, Holle R, et al. Radiographic defect depth and width for prognosis and description of periodontal healing of infrabony defects. J Periodontol. 2001;72(12):1639-46. 5. Parks ET. Digital radiographic imaging: is the dental practice ready? J Am Dent Assoc. 2008;139(4):477-81. 6. Pepelassi EA, Tsiklakis K, Diamanti-Kipioti A. Radiographic detection and assessment of the periodontal endosseous defects. J Clin Periodontol. 2000;27(4):224-30. 7. Wolf B, von Bethlenfalvy E, Hassfeld S, Staehle HJ, Eickholz P. Reliability of assessing interproximal bone loss by digital radiography: intrabony defects. J Clin Periodontol. 2001;28(9):869-78. 8. Goodson J, Haffajee A, Socransky S. The relationship between attachment level loss and alveolar bone loss. Clin Periodontol. 1984;11(5):348-59. 9. Parks ET, Williamson GF. Digital radiography: an overview. J Contemp Dent Pract. 2002;3(4):23-39. 10. Parks ET. Practical techniques to optimize digital radiographic imaging. Pract Proced Aesthet Dent. 2008;20(2):94-8. Iran J Radiol. 2012;9(2) 87