Effect of Filtration and Thickness of Cross-Sections of Cone Beam Computed Tomography Images on Detection of Proximal Caries

Similar documents
Efficacy of the Edge Enhancement Filter of Digital Radiography in the Detection of Proximal Enamel Caries in Premolars

Diagnostic performance of cone-beam computed tomography on detection of mechanically-created artificial secondary caries

Diagnostic Value of Conventional and Digital Radiography for Detection of Cavitated and Non-Cavitated Proximal Caries

Performance of digital radiography with enhancement filters for the diagnosis of proximal caries

Proximal caries detection accuracy using intraoral bitewing radiography, extraoral bitewing radiography and panoramic radiography

Efficacy of Pseudocolor Tool of Digital System in the Detection of Proximal Caries

In vitro comparison of conventional film and direct digital imaging in the detection of approximal caries

Journal of Oral & Dental Health

-./ Accuracy of digital panoramic in detection of interproximal caries ! " # 8 9-/ 0 567:: /0 1 :

Agreement of Digital Panoramic Radiographs with and without Software Enhancement in the Diagnosis of Proximal Dental Caries in Primary Molars

Validity of wax and acrylic as soft-tissue simulation materials used in in vitro radiographic studies

Radiographic Evaluation of Bone Formation and Density Changes after Mandibular Third Molar Extraction: A 6 Month Follow up

Mædica - a Journal of Clinical Medicine. Interobserver variability of the diagnosis of apical periodontitis on panoramic radiography assessment

Accuracy of digital periapical radiography and cone-beam computed tomography in detecting external root resorption

Current Concepts in Caries Management Diagnostic, Treatment and Ethical/Medico-Legal Considerations. Radiographic Caries Diagnosis

Diagnostic Accuracy of Digitized Images Using Different Resolution Settings of Digital Camera in Detection of Proximal Caries

Periapical radiography and cone beam computed tomography for assessment of the periapical bone defect 1 week and 12 months after root-end resection

Diagnostic accuracy of conventional radiography and digital radiography in detecting of root fractures (invitro study)

Journal of Dental School 2014; 32(1): 23-29

Zahra Dalili Kajan 1, *, Reza Tayefeh Davalloo 2, Mayam Tavangar 2, Fatemeh Valizade 3. Introduction

Assessment of enamel-dentin caries lesions

Assessing the Accuracy of Caries Diagnosis in Bitewing Radiographs Using Different Reproduction Media

Comparison of conventional radiography with cone beam computed tomography for detection of vertical root fractures: an in vitro study

Detection of in vitro proximal caries in storage phosphor plate radiographs scanned with different resolutions

Accuracy of Conventional and Digital Radiography in Detecting External Root Resorption

Evaluation of Cone Beam Computed Tomography in Diagnosis and Treatment Plan of Impacted Maxillary Canines

HEAD & NECK IMAGING. Diagnostic Accuracy of Digital and Conventional Radiography in the Detection of Non-Cavitated Approximal Dental Caries

Effect of Developer Age and Film Speed on Diagnostic Accuracy of Endodontic File Length Measurement on Radiographs

Use of the ICDAS system and two fluorescence-based intraoral devices for examination of occlusal surfaces

Accuracy of chemically created periapical lesion measurements using limited cone beam computed tomography

The effect of metal artifacts on the identification of vertical root fractures using different fields of view in cone-beam computed tomography

In vitro cone beam computed tomography imaging of periodontal bone

Course File 243 DDS Physics of Diagnostic Radiology and Oral and Maxillofacial Radiology

Reliability of Orthopantomography and Cone-beam Computed Tomography in Presurgical Implant Planning: A Clinical Study

Research Article In Vitro Evaluation of Proximal Carious Lesions Using Digital Radiographic Systems

Original Research Article

Periapical radiographic technique errors made with film and phosphor plates

Comparison of panoramic radiography with cone beam CT in predicting the relationship of the mandibular third molar roots to the alveolar canal

Interproximal Caries Detection Ability of Dental Practitioners Using Direct Digital System and Conventional Films

DENTAL LEARNING. AN UPDATE ON Bitewing Radiography Technology. Knowledge for Clinical Practice. Credits. Brad Potter, DDS, MS Page 3.

Diagnostic value of two modes of cone-beam computed tomography in evaluation of simulated external root resorption: an in vitro study

Diagnostic Values of Laser Fluorescence Device Compared to Other Techniques in Occlusal Caries Detection

Assessment of the relationship between the maxillary molars and adjacent structures using cone beam computed tomography

Evidence-based decision-making in endodontics

International Journal of Current Medical and Pharmaceutical Research

Diagnostic accuracy of conventional, digital and Cone Beam CT in vertical root fracture detection

Diagnostic Challange: Instances Mimicking a Proximal Carious Lesion Detected by Bitewing Radiography

Managing Cone Beam CT Dose in Paediatric Dental Imaging

The Effect of X Ray Vertical Angulation on Radiographic Assessment of Alveolar Bone Loss

Evaluation of Diagnostic Efficacy of Digital Subtraction Radiography in the Diagnosis of Simulated External Root Resorption: An in Vitro Study

CBCT Specific Guidelines for South African Practice as Indicated by Current Literature:

A comparative study of cone-beam computed tomography and digital periapical radiography in detecting mandibular molars root perforations

Periodontal Disease. Radiology of Periodontal Disease. Periodontal Disease. The Role of Radiology in Assessment of Periodontal Disease

A COMPARISON OF THE CLINICAL AXIAL EXTENSION OF CLASS II CARIOUS LESIONS WITH DIFFERENT DIAGNOSTIC IMAGES

The Agreement of Paper and Film Prints in Detection of Dentinal Caries in Panoramic Radiography

Monday Morning Pearls of Practice by Bobby Baig

Effect of different exposure settings on the diagnosis of vertical root fractures on cone-beam computed tomography images

The influence of sensor size and orientation on image quality in intra-oral periapical radiography

Dental Radiography Core Subject. Digital Radiography

Visibility of Artificial Buccal Recurrent Caries Under Restorations Using Different Radiographic Techniques

Two-dimensional (2D) images have provided. Cone Beam Computed Tomography in Dentistry: What Dental Educators and Learners Should Know

The effect of different exposure parameters on proximal caries detection using the Kodak D CBCT system

Comparison of diagnostic methods for early interproximal caries detection with near-infrared light transillumination: an in vivo study

Evaluation of Morphology and Anatomical Measurement of Nasopalatine Canal Using Cone Beam Computed Tomography

Influence of education level and experience on detection of approximal caries in digital dental radiographs. An in vitro study

Justification of CBCT and Guidelines for Clinical Use

WaveOne Gold reciprocating instruments: clinical application in the private practice: Part 2

Accuracy of CBCT as modality to identify the presence of secondary mesiobuccal root canal in the maxillary first molar

Extraoral Imaging. Chapter 42. Copyright 2018, Elsevier Inc. All Rights Reserved. 1

EVALUATION OF ROOT ANATOMY AND MORPHOLOGY OF MANDIBULAR PREMOLARS WITH CBCT IN IRANIAN POPULATION ABSTRACT

Estimation of Clinical Axial Extension of Class II Caries Lesions with Ultraspeed and Digital Radiographs: An In-vivo Study

Clinical comparison of dental caries by DMFT and ICDA systems

Scientific Affairs. Scientific Affairs

Sang-Sun Han, 1 Kwang-Min Lee, 2 and Kee-Deog Kim Introduction

Effect of Metal Artifacts on Detection of Vertical Root Fractures Using Two Cone-Beam Computed Tomography Systems

SCIENTIFIC ARTICLES. Stomatologija, Baltic Dental and Maxillofacial Journal, 2008, Vol. 10, No SUMMARY

Awareness and Attitude among Dental Professional towards CBCT

Multiple Idiopathic Apical Root Resorption: a Case Report

Dimensional stability in composite cone beam computed tomography

Intraoral Imaging. Chapter 41. Copyright 2018, Elsevier Inc. All Rights Reserved. 1

Assessment of Root Resorption and Root Shape by Periapical and Panoramic Radiographs: A Comparative Study

Proximal Caries Detection in Permanent Teeth by Using DIAGNOcam: An in Vivo Study

Assistant Professor, Head of Department Oral and Maxillofacial Radiology, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran 2

User Guide for Dental and Maxillofacial Cone Beam Computed Tomography (CBCT)

IJBPAS, September, 2015, 4(9), Special Issue: ISSN: AGE ESTIMATION USING DIGITAL PANORAMIC RADIOGRAPHY

Original Paper. D.F. Côrtes a K.R. Ekstrand b A.R. Elias-Boneta c, R.P. Ellwood d

SEDENTEXCT: Guidelines and evidence-based use of CBCT

Cone Beam Computed Tomography (CBCT) and Digital Radiographies Requested and Related Factors by Iranian General Dentists

CASE REPORT. CBCT-Assisted Treatment of the Failing Long Span Bridge with Staged and Immediate Load Implant Restoration

Detection of simulated incipient furcation involvement by CBCT: an in vitro study using pig mandibles

Original Article. , D. Sadri 2, S. Nemati 3, S. Sarikhani 4, A. Zafarfazeli 5.

Introducing a Dental Caries Marking Software and Evaluate Radiologists Disagreement in Caries Detection Using this Software

Dr. Muhannad Abdulrhman Muhammed Halwani, Rakan Saed Safar Al Thobaiti and Abdallah Ali M Asker

Assessment of periapical status: A comparative study using film-based periapical radiographs and digital panoramic images

Visibility of Maxillary and Mandibular Anatomical Landmarks in Digital Panoramic Radiographs: A Retrospective Study

Dental Radiography Series

The Effect of Bite Registration on the Reproducibility of Parallel Periapical Radiographs Obtained with Two Month Intervals

Vertical root fractures (VRFs) are difficult to diagnose by conventional periapical

Age estimation of indian adults from orthopantomographs

Biological Forum An International Journal 7(2): (2015)

Transcription:

Original Article Effect of Filtration and Thickness of Cross-Sections of Cone Beam Computed Tomography Images on Detection of Proximal Caries Mehrdad Abdinian 1, Rahman Nazeri 2, Marzieh Ghaiour 3 1 Assistant Professor, Dental Implants Research Center, Department of Oral and Maxillofacial Radiology, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran 2 Postgraduate Student, Department of Research, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran 3 Postgraduate Student, Department of Pediatric Dentistry, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran Corresponding author: M. Ghaiour, Department of Pediatric Dentistry, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran marzieh.ghaiour@gmail.com Received: 15 April 2017 Accepted: 8 June 2017 Abstract Objectives: When a patient has cone beam computed tomography (CBCT) images based on the treatment plan, it is possible to use these images for evaluation of caries, and there is no need for new radiographs, according to the "as low as reasonably achievable" (ALARA) principle. The aim of this study was to determine the effect of filtration and thickness of CBCT cross-sections on detection of proximal caries. Materials and Methods: In this in-vitro study, 100 teeth were placed in the dental sockets of a dry skull, and were fixed in normal proximal contacts. CBCT images were taken and were evaluated by two observers on the panoramic view at 1-, 3- and 5-mm-thick crosssections, with the use of filtrations 0, 1 and 2. Afterwards, the samples were sectioned and underwent a histological evaluation. McNemar s test was used to compare the findings on CBCT images and histological evaluation. Receiver operating characteristic (ROC) curves and logistic regression were used to evaluate the diagnostic accuracy of different crosssections. Results: The maximum AZ-value was achieved at 3-mm thickness/filtration 2. However, the differences between 1-mm thickness/filtration 2 and 1-mm thickness/filtration 1 were not significant (P=0.728 and 0.868, respectively). The minimum AZ-value was achieved at 5-mm thickness/filtration 0. Conclusions: Although CBCT is not sufficiently effective in detecting caries, the best cross-sections for detection of proximal caries were achieved at 3-mm thickness/filtration 2, 1-mm thickness/filtration 2 and 1-mm thickness/filtration 1. Key words: Dental Caries; Radiography; Tomography; Diagnosis Journal of Dentistry, Tehran University of Medical Sciences, Tehran, Iran (2017; Vol. 14, No. 4) INTRODUCTION Dental caries is the most prevalent clinical problem in dentistry and has a high incidence rate in the population [1]. Therefore, dentists should be able to make a correct and early diagnosis of dental caries. It is necessary to have a proper knowledge of the depth of caries in order to prepare an appropriate treatment plan [2,3]. Clinical and visual examinations, illumination and intraoral radiography with conventional and digital radiographic techniques are the most commonly used diagnostic methods implemented by dentists to detect caries [4-6]. However, diagnosis of interproximal caries in posterior teeth is still a challenge in dentistry, and it usually requires a combination of clinical and radiographic examinations [1,7]. In recent years, conventional bitewing radiography has been the most commonly used technique to this end [8,9]. Digital radiography systems were introduced in early 1990. These systems make it possible to manipulate image contrast and brightness to improve the diagnostic quality of the image [10]. One of these digital systems is cone-beam computed tomography (CBCT). 223 www.jdt.tums.ac.ir July 2017; Vol.14, No. 4

J Dent (Tehran) Fig. 1: Placement of the teeth in a normal anatomical position This new technique helps dental practitioners to collect data and improve treatment planning with the use of three-dimensional (3D) images at axial, sagittal and coronal cross-sections [11]. CBCT technique is used in different fields of dentistry [4]. Although the use of CBCT images for detection of proximal caries has previously been evaluated, there are still doubts about the superiority of CBCT systems over conventional systems [5,12-19]. However, based on a search by the authors of the present study, no studies to date have evaluated the effect of the thickness of cross-sections and filtration on the accuracy of caries detection on CBCT images. Therefore, the present study was undertaken to evaluate the diagnostic accuracy of CBCT systems for detection of proximal caries, and also to evaluate the effect of cross-section thickness and filtration (resolution) of images on detection of proximal caries, with the null hypothesis that CBCT images are not accurate enough for detection of caries. Abdinian et al periodontal or orthodontic reasons at the School of Dentistry, Isfahan University of Medical Sciences. The teeth were cleaned of all the calculi and debris using an ultrasonic device (Cavitron JEJ Plus Ultrasonic Scaler, Dentsply, Milford, USA), were disinfected in 2% sodium hypochlorite (NaOCl) solution for 20 minutes, and were stored in distilled water. Then, the crowns were separated from the roots using a #835 bur (0.8, Tizkavan, Iran). The dental crowns were divided into 20 groups (n=5). Ten groups included maxillary teeth, and the rest included mandibular teeth. Each group consisted of a canine, first and second premolars and first and second molars in one quadrant. Five dry skulls were prepared, and 4 groups of teeth were placed in the alveolar sockets of each skull so that the teeth in each group were placed in their real anatomical positions, with proper proximal contacts in the maxillary and mandibular alveolar sockets. Finally, the teeth were fixed in their sockets with red utility wax. The placement was done in a way that each row was in a good proximal contact. The mandibular and maxillary teeth were occluded together, and were fixed by wax (this positioning simulates a normal anatomical position), (Fig. 1). To simulate soft tissues and the effect of their distribution, an acrylic resin block, measuring 14.5 mm in thickness, was placed in front of the teeth [20]. Subsequently, the mesial and distal surfaces of the five teeth in each group were evaluated for caries; a total of 200 surfaces in 100 teeth were evaluated. MATERIALS AND METHODS In the present in-vitro study, 100 human teeth, consisting of 20 canines, 40 premolars and 40 molars with or without proximal caries were selected from among 400 teeth, using simple random technique. The teeth had been extracted for Fig. 2: CBCT image of the skull holding the teeth 224 www.jdt.tums.ac.ir July 2017; Vol.14, No. 4

Abdinian et al Effect of CBCT Options on Proximal Caries Detection Fig. 3: ROC curve of different filtrations and thicknesses (pan th1f0= thickness 1 filtration 0, pan th1f1=thickness 1 filtration 1, pan th1f2= thickness 1 filtration 2, pan th3f0= thickness 3 filtration 0, pan th3f1=thickness 3 filtration 1, pan th3f2= thickness 3 filtration 2, pan th5f0= thickness 5 filtration 0, pan th5f1=thickness 5 filtration 1, pan th5f2= thickness 5 filtration 2) In the next stage, CBCT images were taken with the use of Soredex CBCT unit (Helsinki, Finland). Each skull was fixed in the CBCT system with the use of ear rods and was scanned for 12.6 seconds at kilovoltage peak (kvp)=89 and milliampere (ma)=6. The images were reconstructed with the system s software program (OnDemand 3D Dental 1.0.9.1343). Figure 2 shows a CBCT image of the skull holding the teeth. The images were evaluated by two oral and maxillofacial radiologists with 6 years of experience in a random single-blind manner. The images were visualized on a 22-inch 32-bit LG monitor (LG, Seoul, Korea) with a resolution of 1440 690 pixels, using the CBCT system's software program in a dimly lit room. The observers scored the images on the panoramic view (mesiodistal) with three different filtrations (resolutions) of 0, 1 and 2, and three different cross-section thicknesses of 1, 3 and 5 mm, based on the presence or absence of proximal cares in a 5-point scale [21], as follows: 1. Definitively carious 2. Possibly carious 3. Not definitive and suspected 4. Possibly not carious 5. Definitively not carious In order to evaluate intra-observer agreement, the observers evaluated and scored the images twice with an interval of two weeks, in order to eliminate the effect of memory. Subsequently, the teeth were sectioned mesiodistally, parallel to the tooth long axis with a mean cross-section thickness of 0.4mm, using Accutom cutting instrument (Struers, Ballerup, Denmark). Each cross-section was evaluated by a pathologist under a stereomicroscope at 15 magnification. Each white demineralized lesion or yellow-brown discoloration in enamel or dentin was considered a carious lesion in the histopathological view [5]. Of all the crosssections of each tooth, one cross-section with the greatest depth was selected for scoring of that July 2017; Vol.14, No. 4 www.jdt.tums.ac.ir 225

J Dent (Tehran) Table 1. Percentage of carious lesions in each dental region Caries Situation Frequency Percentage Without caries 54 27 Caries in enamel 57 28.5 Caries in the external half of dentin 48 24 Caries in the internal half of dentin 41 20.5 tooth based on the following scoring system: 1. No caries in the proximal surface 2. Proximal caries in enamel 3. Proximal caries extending to the dentino-enamel junction (DEJ) or located in the external half of dentin Kappa agreement coefficient was calculated for intra- and inter-observer agreement, and was classified as follows: 0.10 <: No agreement 0.11-0.4: Poor agreement 0.41-0.60: Acceptable agreement 0.61-0.80: Strong agreement 0.81-1.0: Excellent agreement In order to evaluate the accuracy of caries detection in different radiologic cross-sections, the results reported by the radiologists were compared with the histopathology findings using complete and absolute sensitivity, specificity and the receiver operating characteristics (ROC) analysis. Values under the ROC curve (AZ-values) were calculated for different cross-sections using SPSS 22 software program (IBM Co., Chicago, IL, USA). Wilson confidence interval-based comparison was used to evaluate the differences in the accuracy of different cross-sections (α = 0.05). RESULTS Table 1 presents the histopathologic status of 200 proximal dental surfaces. According to this Table, 27% of the surfaces were not carious, while carious lesions were detected in 73% of the surfaces. At different cross-section thicknesses and filtrations, intra-observer kappa coefficients of observers 1 and 2 were in the ranges of 0.759-0.884 and 0.716-0.867, respectively. However, inter-observer kappa Abdinian et al coefficient was in the range of 0.631-0.769, which was calculated based on the means of data provided by each observer for each parameter. A high intraobserver kappa coefficient indicates a strong intraobserver agreement. Therefore, our calculations were made by considering the first readings of each observer. Table 2 shows the results of sensitivity and specificity of different thicknesses and filtrations. The results indicated a direct correlation between filtration and correct diagnosis in CBCT, and a reverse correlation between the thickness of view and correct diagnosis in CBCT. Figure 3 presents the ROC curve of different filtration and thicknesses according to the histopathological results. Table 3 shows the AZ-value of different views resulted from the ROC curve. The results showed a direct correlation between the histopathological and radiologic results. Based on the P-values presented in Table 3, AZ-values of all the cross-sections and filtrations were significantly higher than the 0.5 reference point of the AZ-value (P<0.05). The highest AZ-value was achieved at 3-mm thickness/filtration 2, with the lowest AZ-value at 5- mm thickness/ filtration 0. Although the AZ-values of different filtrations and thicknesses were almost the same, based on Wilson test, the best view was achieved at 3-mm thickness/filtration 2, which exhibited significant differences in diagnostic accuracy from 1-mm thickness/filtration 0 (P<0.001), 3-mm thickness/filtration 0 (P<0.001), 3-mm thickness/filtration 1 (P<0.001), 5-mm thickness/filtration 1 (P<0.001) and 5-mm thickness/filtration 2 (P=0.046). However, there were no significant differences between 3-mm thickness/filtration 2 and 1-mm thickness/filtration 1 (P=0.617), or between 3-mm thickness/filtration 2 and 1-mm thickness/filtration 2 (P=0.459). Table 4 shows the means of correct diagnoses of carious lesions at different thicknesses and filtrations. According to this Table, the most accurate diagnoses were related to the teeth with carious lesions in the external half of dentin, followed by carious lesions in the internal half of dentin. 226 www.jdt.tums.ac.ir July 2017; Vol.14, No. 4

Abdinian et al Effect of CBCT Options on Proximal Caries Detection Table 2. Absolute and complete sensitivity and specificity of caries detection at different thicknesses and filtrations Thickness (mm) 1 2 3 Filtration Absolute Complete Absolute Complete sensitivity sensitivity specificity specificity 0 0.556 0.667 0.644 0.719 1 0.130 0.815 0.260 0.493 2 0.556 0.686 0.555 0.692 0 0.074 0.500 0.219 0.431 1 0.500 0.778 0.479 0.616 2 0.648 0.759 0.616 0.719 0 0 0.167 0.144 0.267 1 0.093 0.389 0.295 0.507 2 0.278 0.537 0.493 0.637 The most inaccurate diagnoses in all the crosssections were related to the teeth with enamel caries except for 1-mm thickness/filtration 0, in which caries-free teeth were more accurately diagnosed compared to the teeth with carious lesions in the external half of dentin. DISCUSSION CBCT is a new imaging technique in dentistry. All the new diagnostic methods should be compared with the imaging techniques that are currently used in the clinic. Although there are some studies available in this regard, there are still some debates in relation to the efficacy of the CBCT technique [14]. Akdeniz et al [12] reported that CBCT might prove promising for monitoring small carious lesions. Tsuchida et al [13] reported that the 3D Accuitomo CBCT system was not accurate enough for detection of proximal caries in comparison to conventional film radiography. An in-vitro study by Haiter-Neto et al [14] showed a reverse correlation between the size of the field of view (FOV) and diagnostic efficacy. Qu et al [22] stated that the type of CBCT system and the size of the FOV have no effect on the diagnostic accuracy of proximal caries. Charuakkra et al [11] reported that axial crosssections are the most favorable views to study proximal caries. Based on a search carried out by the authors of the present study, no studies to date have evaluated the effect of cross-section thickness and filtration on the efficacy of CBCT images in detecting proximal caries. In the present study, both inter- and intra-observer coefficients were high (strong to excellent), indicating that the observers had been trained well and were calibrated. The results of the logistic regression of different views showed a direct correlation between filtration and correct diagnosis in CBCT, and a reverse relationship between the thickness of views and correct diagnosis in CBCT. Therefore, the increase of thickness decreases the number of correct diagnoses, whereas the increase of filtration, increases the number of true diagnoses in CBCT. In this study, ROC curves were used to evaluate the diagnostic accuracy of different cross-section thicknesses and filtration rates. ROC analysis is a more comprehensive parameter for evaluation of diagnostic accuracy compared to sensitivity and specificity [23]. Table 3. Az-values, standard errors (SE) and significance levels of data Test Value Cut-off Azvalue SE TH1/F0 0.731 0.040 <0.001 TH1/F1 0.752 0.035 <0.001 TH1/F2 0.758 0.037 <0.001 TH3/F0 0.726 0.039 <0.001 TH3/F1 0.775 0.038 <0.001 TH3/F2 0.794 0.038 <0.001 TH5/F0 0.673 0.040.007 TH5/F1 0.740 0.036 <0.001 TH5/F2 0.768 0.038 <0.001 TH =Thickness, F=Filtration P-value (asymptomatic sig.) July 2017; Vol.14, No. 4 www.jdt.tums.ac.ir 227

J Dent (Tehran) Abdinian et al Table 4. Average percentage of the correct diagnoses (accuracy) of the two observers at different views Test Value Cut-off Without caries Caries in enamel Caries in the external half of dentin Caries in the internal half of dentin TH1/F0 81.4 12.2 62.5 85.3 TH1/F1 68.5 42.1 81.2 92.6 TH1/F2 66.6 45.6 85.4 92.6 TH3/F0 50 12.2 50 78.0 TH3/F1 77.7 31.5 81.2 87.8 TH3/F2 75.9 45.6 87.5 90.2 TH5/F0 16.6 7 22.9 58.5 TH5/F1 38.8 29.3 56.2 78 TH5/F2 53.7 38.5 75 85.3 TH =Thickness, F=Filtration In addition, ROC analysis is a more eloquent parameter for comparison of the diagnostic performance of two or more diagnostic techniques, because it is less significantly affected by the inherent ability of the observer to interpret images, and has been used in various studies [23,24]. In the present study, the AZ-value range was 0.67-0.79. To interpret this finding, it should be pointed out that values approaching 1 indicate a proper test, and values approaching 0.5 indicate poor results of the test [25]. According to the AZ-values in the present study, CBCT technique cannot be considered an accurate tool for evaluation of caries. AZ-value of 3-mm thickness/filtration 2 was significantly higher than that of the other thicknesses; however, there were no significant differences between the cross-sections mentioned above and the two cross-sections with 1-mm thickness/filtration 1 and 1-mm thickness/filtration 2. Therefore, these views were the best views for evaluation of proximal caries. In a study by Zhang et al [15], AZ-values were calculated near the chance value (0.5) with the use of Promax 3D and Kodak 3D900 systems [15]. In studies carried out by Zhang et al [15] and Haiter-Neto et al [14], the AZ-value for diagnosis of incipient proximal caries was in the 0.59-0.64 range. The low AZ-value in these studies might be explained by the fact that evaluations were carried out on incipient enamel carious lesions. However, AZvalues in some other studies [13,21] were higher than that in the present study. In studies by Belem et al [21], and Kayipmaz et al [17], the AZ-values were 0.87 and 0.84, respectively. Another study with high AZ-values has been performed by Charuakkra et al [11]. High AZ-values in these studies might be attributed to the thin CBCT cross-sections of dental structures, yielding a high contrast between carious lesions and sound dental structures that resulted in fewer misinterpretations; as a result, incorrect diagnoses decreased, while AZ-values increased. In the present study, low AZ-values might be attributed to the thickness of cross-sections; therefore, some carious lesions were left undetected. Based on the results of the present research, the highest AZ-value was related to 3-mm thickness, which might be explained by the fact that there is an increase in the noise of cross-sections as the cross-section thickness decreases; on the other hand, with an increase in thickness, diagnosis of caries 228 www.jdt.tums.ac.ir July 2017; Vol.14, No. 4

Abdinian et al becomes more difficult due to the effect of partial volume averaging. Therefore, medium thicknesses show proximal caries better than other thicknesses. It is necessary to simultaneously evaluate sensitivity and specificity to compare the diagnostic accuracy of different diagnostic views [25]. Analysis of the ROC curve and AZ-values properly achieve this aim [26, 27]. In the present study, the AZ-values were almost similar in different cross-sections; however, the highest values were related to 3-mm thickness/filtration 2, 1-mm thickness/filtration 1 and 1-mm thickness/filtration 2. Therefore, these views can be considered the best views for diagnosis of caries among all the views evaluated in the current study. Considering the "as low as reasonably achievable" (ALARA) principle, there should be a strong justification for the use of CBCT system before performing any other radiographic examination, and given the low AZvalues of this system, the evidence-based selection criteria should be considered. In this context, the present study did not support the use of CBCT system for diagnosis of caries. One of the limitations of the present study was the fact that only the panoramic view of the CBCT system was evaluated, while axial views were not assessed. In addition, a limited number of cross-sections was evaluated in the present study to detect caries. Another limitation of the present study was the fact that this study has been carried out in vitro under ideal conditions, and non-moving objects were radiographed in the absence of metallic restorations and tissues around the teeth, which might complicate detection of caries in vivo. CONCLUSION Within the limitations of the present study, it has been concluded that CBCT technique is not accurate enough for evaluation of proximal caries. The best cross-sections for evaluation of caries were achieved at 3-mm thickness/filtration 2, 1-mm thickness/filtration 1 and 1-mm thickness/filtration 2. Effect of CBCT Options on Proximal Caries Detection REFERENCES 1- Pereira AC, Verdonschot EH, Huysmans MC. Caries detection methods: can they aid decision making for invasive sealant treatment? Caries Res. 2001 Mar-Apr;35(2):83-9. 2- Attrill DC, Ashley PF. Occlusal caries detection in primary teeth: a comparison of DIAGNOdent with conventional methods. Br Dent J. 2001 Apr 28;190(8):440-3. 3- Ohki M, Okano T, Nakamura T. Factors determining the diagnostic accuracy of digitized conventional intraoral radiographs. Dentomaxillofac Radiol. 1994 May;23(2):77-82. 4- White SC, Pharoah MJ. Oral Radiology: Principles and Interpretation: Elsevier Health Sciences, 2013:285. 5- Senel B, Kamburoglu K, Ucok O, Yuksel SP, Ozen T, Avsever H. Diagnostic accuracy of different imaging modalities in detection of proximal caries. Dentomaxillofac Radiol. 2010 Dec;39(8):501-11. 6- Haak R, Wicht MJ, Noack MJ. Conventional, digital and contrast-enhanced bitewing radiographs in the decision to restore approximal carious lesions. Caries Res. 2001 May-Jun;35(3):193-9. 7- Hala LA, Mello JBd, Carvalho PLd. Evaluation of the effectiveness of clinical and radiographic analysis for the diagnosis of proximal caries for different clinical experience levels: comparing lesion depth through histological analysis. Braz J Oral Sci. 2006;5:1012-7. 8- Wenzel A. Bitewing and digital bitewing radiography for detection of caries lesions. J Dent Res. 2004;83 Spec No C(C):C72-5. 9- Jablonski-Momeni A, Stachniss V, Ricketts DN, Heinzel-Gutenbrunner M, Pieper K. Reproducibility and accuracy of the ICDAS-II for detection of occlusal caries in vitro. Caries Res. 2008;42(2):79-87. 10- Isidor S, Faaborg-Andersen M, Hintze H, Kirkevang LL, Frydenberg M, Haiter-Neto F, et al. Effect of monitor display on detection of approximal caries lesions in digital radiographs. Dentomaxillofac Radiol. 2009 Dec;38(8):537-41. 11- Charuakkra A, Prapayasatok S, Janhom A, Pongsiriwet S, Verochana K, Mahasantipiya P. Diagnostic performance of cone-beam computed tomography on detection of mechanically-created artificial secondary caries. Imaging Sci Dent. 2011 Dec;41(4):143-50. July 2017; Vol.14, No. 4 www.jdt.tums.ac.ir 229

J Dent (Tehran) 12- Akdeniz BG, Grondahl HG, Magnusson B. Accuracy of proximal caries depth measurements: comparison between limited cone beam computed tomography, storage phosphor and film radiography. Caries Res. 2006;40(3):202-7. 13- Tsuchida R, Araki K, Okano T. Evaluation of a limited cone-beam volumetric imaging system: comparison with film radiography in detecting incipient proximal caries. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2007 Sep;104(3):412-6. 14- Haiter-Neto F, Wenzel A, Gotfredsen E. Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions. Dentomaxillofac Radiol. 2008 Jan;37(1):18-22. 15- Zhang ZL, Qu XM, Li G, Zhang ZY, Ma XC. The detection accuracies for proximal caries by conebeam computerized tomography, film, and phosphor plates. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2011 Jan;111(1):103-8. 16- Young SM, Lee JT, Hodges RJ, Chang TL, Elashoff DA, White SC. A comparative study of high-resolution cone beam computed tomography and charge-coupled device sensors for detecting caries. Dentomaxillofac Radiol. 2009 Oct;38(7):445-51. 17- Kayipmaz S, Sezgin OS, Saricaoglu ST, Can G. An in vitro comparison of diagnostic abilities of conventional radiography, storage phosphor, and cone beam computed tomography to determine occlusal and approximal caries. Eur J Radiol. 2011;80(2):478-82. 18- Wenzel A, Hirsch E, Christensen J, Matzen LH, Scaf G, Frydenberg M. Detection of cavitated approximal surfaces using cone beam CT and intraoral receptors. Dentomaxillofac Radiol. 2013;42(1):39458105. 19- Valizadeh S, Tavakkoli MA, Karimi Vasigh H, Azizi Z, Zarrabian T. Evaluation of Cone Beam Computed Tomography (CBCT) System: Comparison with Intraoral Abdinian et al Periapical Radiography in Proximal Caries Detection. J Dent Res Dent Clin Dent Prospects. 2012 Winter;6(1):1-5. 20- Schropp L, Alyass NS, Wenzel A, Stavropoulos A. Validity of wax and acrylic as soft-tissue simulation materials used in in vitro radiographic studies. Dentomaxillofac Radiol. 2012 Dec;41(8):686-90. 21- Belem MD, Tabchoury CP, Ferreira-Santos RI, Groppo FC, Haiter-Neto F. Performance of a photostimulable storage phosphor digital system with or without the sharpen filter and cone beam CT for detecting approximal enamel subsurface demineralization. Dentomaxillofac Radiol. 2013;42(5):20120313. 22- Qu X, Li G, Zhang Z, Ma X. Detection accuracy of in vitro approximal caries by cone beam computed tomography images. Eur J Radiol. 2011 Aug;79(2):e24-7. 23- Kositbowornchai S, Basiw M, Promwang Y, Moragorn H, Sooksuntisakoonchai N. Accuracy of diagnosing occlusal caries using enhanced digital images. Dentomaxillofac Radiol. 2004 Jul;33(4):236-40. 24- Tyndall DA, Ludlow JB, Platin E, Nair M. A comparison of Kodak Ektaspeed Plus film and the Siemens Sidexis digital imaging system for caries detection using receiver operating characteristic analysis. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1998 Jan;85(1):113-8. 25- Akkaya N, Kansu O, Kansu H, Cagirankaya LB, Arslan U. Comparing the accuracy of panoramic and intraoral radiography in the diagnosis of proximal caries. Dentomaxillofac Radiol. 2006 May; 35(3): 170-4. 26- Berkey CS, Douglass CW, Valachovic RW, Chauncey HH, McNeil BJ. Statistical methods for comparing dental diagnostic procedures. Community Dent Oral Epidemiol. 1990 Aug;18(4):169-76. 27- Obuchowski NA. Receiver operating characteristic curves and their use in radiology. Radiology. 2003 Oct;229(1):3-8. 230 www.jdt.tums.ac.ir July 2017; Vol.14, No. 4