APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1

Similar documents
Core-Shell Technology for Proteins and Peptides

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology.

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns.

Preparative Chromatography Meets UHPLC

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1.

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns

APPLICATIONS TN Determination of Sugars in Animal Feed using HPLC-ELSD

APPLICATIONS TN Analytical Method

Finally, a Solid Phase Extraction product for Drugs of Abuse

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases

Yes You Can! New! Amazing EVO C18. Core-Shell Technology

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market

Protect Your Mass Spec

APPLICATIONS TN Materials and Methods

NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you!

Figure 1. Core-Shell Particle Technology

SIMPLIFIED CHIRAL SEPARATIONS. Lux Cellulose-1. Guaranteed Alternative. to CHIRALCEL OD-H. Exceptional Quality Sensibly Priced

Labs Across the World Are Advancing Their Protein Precipitation

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE

COMBO ULTIMATE HPLC/UHPLC. Kinetex + Luna Omega NEW. Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput

Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS. JWH018-4-Hydroxypentyl metabolite

Phospholipid Removal Solutions

METHAMPHETAMINE & AMPHETAMINE

PAIN PANEL. Research and Solutions

APPLICATIONS TN A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE)

Awesome! Unconventionally. Kinetex EVO C18 HPLC/UHPLC Core-Shell Columns 2.6. Core-Shell Technology

Core-Shell Technology. 11 HPLC Myths. Uncovered. & Why You Must Have Kinetex Core-Shell HPLC Columns

Analytical and Preparative SFC Columns

APPLICATIONS TN Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex 2.6 µm Core-Shell Technology Column

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Sepax Technologies, Inc.

Keep It Clean. Solid Phase Extraction Solutions for Drugs of Abuse Analysis. Neutral Drugs of Abuse Basic Drugs of Abuse

A New Era in SFC Column Technology

APPLICATION TN Materials and Methods Reagents and Chemicals

NEW Kinetex F5. HPLC/UHPLC Core-Shell Columns

CANNABIS TESTING ACCESSORIES

Exceed your Purification Goals. Guaranteed. Phenomenex l WEB:

Key Advantages of Comprehensive Cannabis Analysis

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis

ACE C18-AR Use the Power!

SIMPLIFIED CHIRAL SEPARATIONS. FIVE Complementary Chiral Phases. for Greater Selectivity. Resolve 92 %

Eurospher II the logical choice. Physical properties of Eurospher II silica gel: Silica gel: ultra pure, > % Metal content: < 10 ppm

Lux. Five Distinct Polysaccharide Phases to Resolve 92 % of Your Enantiomers* Lux Cellulose-1. Lux Cellulose-3. Lux Cellulose-2.

C30 ISOMERS HAVE MET THEIR MATCH

Impurity Profiling of Carbamazepine by HPLC/UV

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS)

Keep it Clean with Strata -X

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

Prep Columns. and Bulk Media. and Bulk Media

Effective Surface Area (m 2 /g) Pore Size (Å)

TN-0116 Scott Krepich

UNISON UK - Amino For Aqueous Elutions and Exceptional Separation Balance

Unequalled durability against water elution. % tr

LC Columns with Liquid Separation Cell Technology

GlycanPac AXR-1 Columns

Fortis Method Development Options

SeQuant ZIC -HILIC For all who expect more...

Thermo Fisher Scientific, Sunnyvale, CA, USA; 2 Thermo Fisher Scientific, San Jose, CA, USA

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

PAIN PANEL. Application Guide. Screen 41 compounds in under 4 minutes

SeQuant ZIC -HILIC For all who expect more...

176 YMC Chiral Columns

Abstract. Introduction

Bio-Rad Laboratories HEMOGLOBIN Testing Bio-Rad A1c. VARIANT II TURBO Link. Fully-Automated HbA 1c Testing

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Ultimate Core Performance to Maximize Your Investment

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

Separation of Macrocyclic Lactones (Avermectins) on FLARE C18 MM & FLARE C18+ Columns

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

Ultra Columns. also available. ordering note

Vitamin Testing APPLICATIONS GUIDE

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS

Bio-Rad Laboratories HEMOGLOBIN Testing Bio-Rad A1c. VARIANT II TURBO Link System. Fully-Automated HbA 1c Testing

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs. Table 1. List of pain panel drugs

The Raptor HILIC-Si Column

Determination of Water- and Fat-Soluble Vitamins in Nutritional Supplements by HPLC with UV Detection

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

APPLICATION TN Rapid Analysis of a 48 Drug Research Panel in Less Than 4 Minutes Using Kinetex Biphenyl Core-Shell Technology HPLC/UHPLC Columns

Ultra Columns HPLC COLUMNS

LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D

Comparison of a UPLC Method across Multiple UHPLC Systems

Providing a Universal, One-step Alternative to Liquid-Liquid Extraction in Bioanalysis

ApplicationNOTE EXACT MASS MEASUREMENT OF ACTIVE COMPONENTS OF TRADITIONAL HERBAL MEDICINES BY ORTHOGONAL ACCELERATION TIME-OF-FLIGHT.

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific

Restek Ultra II HPLC Columns

Simultaneous Quantitative Analysis of Total Catecholamines and Metanephrines in Urine Using CLEAN UP CCX2 and LC-MS/MS

Forensic and clinical products and services

Impact of Reversed-Phase Chiral Chromatography on the LC-MS Analysis of Drugs in Biological Fluids

Agilent Technologies Prep LC Columns

Improving Food Process Control Using the

APPLICATIONS TN Rapid, High Resolution Analysis of Aflatoxin Extracts from Peanut Butter Using Kinetex Core-Shell Technology and Strata SPE

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system

Systematic Evaluation of Solid Phase Extraction (SPE) Chemistries for the Determination of Acidic, Neutral, and Basic Drugs

Strata-X- NEW! Drug B. Drug B Plus for In-Well Hydrolysis. Simplify Your Solid Phase Extraction.

Pharmacopoeia Methods

Transcription:

APPLICATIONS A Comparison of Various Kinetex C18 Phases Zeshan Aqeel and Jeff Layne Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 91 USA Introduction When performing reversed phase LC separations, there is a natural tendency of method developers to first test a C18 phase, the most commonly used phase in LC applications. Today, there are many different C18 phases available to method developers so choosing a simple C18 column may prove to be more challenging than one had originally thought. This technical note explores the different C18 phases within the Kinetex core-shell family of HPLC/UHPLC columns to determine the differences as well as to provide a general guideline of how to select the most appropriate C18 phase for a variety of applications. Materials and Methods To provide a streamlined method development approach, the following cases were studied to determine the most appropriate C18 phase for each application: Acid, Base, Neutral Panel Highly Polar Analytes Highly Polar Bases (Catecholamines) Highly Polar Bases (Nucleotides) Hydrophobic Neutrals and Acids (Cannabinoids) Three different Kinetex core-shell C18 phases were screened under the same conditions as well as optimized conditions in some cases: Polar Kinetex Polar C18 Combined C18 and polar modified surface that provide polar and non-polar retention alongside 1 % aqueous stability Polar Kinetex C18 Balanced C18 phase that provides the highest degree of hydrophobic selectivity relative to the other Kinetex phases Si Kinetex XB-C18 Unique C18 phase that yields increased hydrogen bonding with hydrophobic selectivity, resulting in improved peak shape for basic compounds and increased retention of acidic compounds Page 1 of 8

Results and Discussion I. Acid, Base, Neutral Panel using a Formic Acid Gradient In general, gradients will reduce selectivity differences between phases as the gradient rate itself will play a large role in analyte elution But, particularly when using formic acid and other weak buffers, differences in ion-exchange and polar interactions will still be apparent, giving subtle (or not so subtle) differences in selectivity These differences will be less apparent when using more strong buffer salts like phosphate, or when using ion-pairing agents (e.g. hexane sulfonic acid) or ion-masking agents (TEA; TFA) Kinetex 2.6 µm Polar C18 2 17 1 1 7 1 2 3 4 6 7 8 9 min 2 17 Dimensions: x 4.6 mm Mobile Phase: A:.1 % Formic acid in Water B:.1 % Formic acid in Acetonitrile Gradient: Time (min) B (%). 1 9 11 9 Flow Rate: 1.8 ml/min Temperature: 3 C App ID 24377 Sample: 1. Pyridine 2. Acetaminophen 3. Sulfathiazole 4. Quinidine. Quinidine Impurity 6. Acebutolol 7. Chlorpheniramine 8. Phenol 9. Triprolidine 1. Prednisolone 11. Nortriptyline 12. -Methylsalicaldehyde 13. Hexanophenone II. Highly Polar Analytes Water-Soluble Vitamins Take advantage of the aqueous stability of Kinetex Polar C18 to perform your analyses in 1 % aqueous conditions to maximize retention of polar analytes Traditional C18 phases like Kinetex C18 or XB-C18 should not be used below 2-3 % organic to maintain phase stability (mobile phase = 1% 2 mm Potassium phosphate, ph 3.) 3 3 2 1 1 2 3 4 ' 6 min 4 3 2 1 Dimensions: x 4.6 mm Mobile Phase: 2 mm Potassium phosphate, ph 3. / Methanol (97:3) (except where noted) Temperature: 3 C Detection: UV @ 21 nm Sample: : 1. Thiamine 2. Nicotinamide 3. Pyridoxal 4. Pyridoxine 1 2 3 4 6 min App ID 24383 App ID 2438 1 1 7 6 1 2 3 4 6 7 8 9 min App ID 24378 4 3 2 1 1 2 3 4 6 min App ID 24381 2 17 1 1 7 1 2 3 4 6 7 8 9 min App ID 24379 6 4 3 2 1 1 2 3 4 6 min App ID 24382 Page 2 of 8 Page 3 of 8

III. Highly Polar Bases Catecholamines Take advantage of the aqueous stability on Kinetex Polar C18 to perform your analyses in 1 % aqueous conditions to maximize retention of polar analytes Traditional C18 phases like Kinetex C18 or XB-C18 should not be used below 2-3 % organic to maintain phase stability (mobile phase = 1 % 2 mm Ammonium acetate, ph 6.9) Dimensions: x 4.6 mm Mobile Phase: 2 mm Ammonium acetate, ph 6.9 / Methanol (98:2) (except where noted) Temperature: Ambient Detection: UV @ 28 nm Sample: 1. Norepinephrine 2. Epinephrine 3. Dopamine 4. Serotonin. -Hydroxy-3-Indoleacetic Acid 6. 4-Hydroxy-3-Methoxyphenylacetic Acid IV. Highly Polar Bases Nucleotides Take advantage of the aqueous stability on Kinetex Polar C18 to perform your analyses in 1 % aqueous conditions to maximize retention of polar analytes. The trade-off can be an increase in tailing, as is apparent below, but we include the data as a logical extreme; one would expect to optimize their method to find the right balance of retention and peak shape The key is that operating in highly aqueous conditions is only possible with the Kinetex Polar C18 phase Dimensions: x 4.6 mm Mobile Phase: 2 mm Ammonium acetate, ph 6.9 / Methanol (97:3) (except where noted) Temperature: Ambient Detection: UV @ 28 nm Sample: 1. Thiourea 2. -Fluorocytosine 3. Adenine 4. Thymine. Guanosine--Monophosphate 2 1 2. 7. 1 12. 17. 2 22. min App ID 24387 (mobile phase = 1 % 2 mm Ammonium acetate, ph 6.9) 12 1 8 6 4 2 2 4 6 8 1 12 14 min App ID 24391 3 3 17. 2 1 2. 7. 1 12. 17. 2 22. min App ID 24384 12. 1 7. 2. 2 4 6 8 1 12 14 min App ID 24388 3 2 1 2. 7. 1 12. 17. 2 22. min App ID 2438 16 14 12 1 8 6 4 2 2 4 6 8 1 12 14 min App ID 24389 17. 2 1 2. 7. 1 12. 17. 2 22. min App ID 24386 12. 1 7. 2. 2 4 6 8 1 12 14 min App ID 2439 Page 4 of 8 Page of 8

V. Hydrophobic Neutrals and Acids Cannabinoids Even very hydrophobic molecules will display selectivity differences on different C18 phases due to structural (e.g. positional isomers) or polar functional groups In this case, although selectivity was similar overall, the traditional Kinetex C18 provided better selectivity for one critical pair (CBN and CBGA), which is interesting because they are totally different structurally one would think could easily separate 14 12 1 8 6 4 2-2 2 4 6 8 1 min 14 12 1 8 6 4 2-2 1 2 3 4 6 7 8 9 1 min 14 12 1 8 6 4 2-2 Sample: 1. CBDV Dimensions: x 4.6 mm Mobile Phase: A:.1 % Formic acid in Water Gradient: B:.1 % Formic acid in Acetonitrile 4. CBD Time (min) B (%). CBG 6 16 1 6. CBDA Flow Rate:. ml/min Temperature: C Detection: UV @ 23 nm 1 2 3 4 6 7 8 9 1 min 7. CBN 2. CBDVA 8. CBGA 3. THC-V 9. D9-THC App ID 24393 App ID 24392 App ID 24394 1. D8-THC 11. CBC 12. THCA-A Conclusions You will find differences in selectivity between the Kinetex C18, Kinetex XB-C18, and Kinetex Polar C18 stationary phases based upon the differences in surface chemistry Under identical running conditions, the differences may be subtle these are after all still all C18 phases but subtle differences can make the difference between resolution and co-elution, or lead to reversals in elution order that can help to resolve a target analyte from matrix interferences With the newest Kinetex Polar C18 phase, however, you can operate in 1 % aqueous conditions, whereas the traditional C18 phases should not go below 2-3 % organic. This opens the Kinetex Ordering Information 1.3 μm Minibore Columns (mm) Phases 3 x 2.1 x 2.1 C18 A-4-AN B-4-AN 1.7 μm MidBore Columns (mm) Phases 3 x 3. x 3. 1 x 3. 3/pk XB-C18 A-4498-Y B-4498-Y D-4498-Y AJ-877 C18 B-447-Y D-447-Y AJ-877 for 3. mm ID 1.7 μm Minibore Columns (mm) Phases 3 x 2.1 x 2.1 1 x 2.1 x 2.1 3/pk EVO C18 B-4726-AN D-4726-AN F-4726-AN AJ-9298 XB-C18 A-4498-AN B-4498-AN D-4498-AN F-4498-AN AJ-8782 C18 A-447-AN B-447-AN D-447-AN F-447-AN AJ-8782 2.6 μm Analytical Columns (mm) Phases 3 x 4.6 x 4.6 7 x 4.6 1 x 4.6 x 4.6 3/pk EVO C18 B-47-E D-47-E F-47-E AJ-9296 Polar C18 B-479-E D-479-E F-479-E AJ-93 XB-C18 B-4496-E C-4496-E D-4496-E F-4496-E AJ-8768 C18 A-4462-E B-4462-E C-4462-E D-4462-E F-4462-E AJ-8768 2.6 μm MidBore Columns (mm) Phases 3 x 3. x 3. 7 x 3. 1 x 3. x 3. 3/pk EVO C18 B-47-Y D-47-Y F-47-Y AJ-9297 Polar C18 B-479-Y D-479-Y F-479-Y AJ-931 XB-C18 A-4496-Y B-4496-Y C-4496-Y D-4496-Y F-4496-Y AJ-877 C18 A-4462-Y B-4462-Y C-4462-Y D-4462-Y F-4462-Y AJ-877 for 3. mm ID 2.6 μm Minibore Columns (mm) Phases 3 x 2.1 x 2.1 7 x 2.1 1 x 2.1 x 2.1 3/pk EVO C18 A-47-AN B-47-AN D-47-AN F-47-AN AJ-9298 Polar C18 A-479-AN B-479-AN D-479-AN F-479-AN AJ-932 XB-C18 A-4496-AN B-4496-AN C-4496-AN D-4496-AN F-4496-AN AJ-8782 C18 A-4462-AN B-4462-AN C-4462-AN D-4462-AN F-4462-AN AJ-8782 potential to generate significant changes in retention for polar molecules. A thorough method development project should involve screening each of these phases, but if only one column could be screened, it is recommended that it be the Kinetex Polar C18, with its ability to operate in 1 % aqueous conditions, followed by either the Kinetex C18 or Kinetex XB-C18 to complement it The Kinetex Polar C18, with its aqueous stability and special surface modification, may provide a benefit for analyzing polar analytes, whereas the standard Kinetex C18 or XB-C18 phases, may be advantageous for separations based upon primarily hydrophobic differences Although it was not included in this study, our Kinetex EVO C18 is the obvious choice for operating in alkaline mobile phases, or when you need improved peak shape for tailing basic analytes, especially when using weakly-buffered mobile phases like.1 % formic acid 1.7 μm Microbore Columns (mm) Phases x 1. 1 x 1. x 1. EVO C18 B-4726-A D-4726-Y F-4726-A More Ordering Information ULTRA Cartridges require holder, Part No.: AJ-9 Page 6 of 8 Page 7 of 8

APPLICATIONS Kinetex Ordering Information 2.6 Microbore Columns (mm) Phases x 1. 1 x 1. x 1. XB-C18 B-4496-A F-4496-E F-4496-A 3. μm Analytical Columns (mm) Phases 1 x 4.6 x 4.6 3/pk XB-C18 B-4496-A D-4796-E AJ-8768 Australia t: +61 ()2-9428-6444 f: +61 ()2-9428-644 au Austria t: +43 ()1-319-131 f: +43 ()1-319-13 anfrage@phenomenex.com Belgium t: +32 ()2 3 4 (French) t: +32 ()2 11 8666 (Dutch) f: +31 ()3-2383749 be Canada t: +1 (8) 43-3681 f: +1 (31) 328-7768 China t: +86 4-66-899 f: +86 ()22 32-133 phen@agela.com Denmark t: +4 4824 848 f: +4 481 626 nordic Finland t: +38 ()9 4789 63 f: +4 481 626 nordic France t: +33 ()1 3 9 21 1 f: +33 ()1 3 9 21 11 france Germany t: +49 ()621-883- f: +49 ()621-883-11 anfrage@phenomenex.com India t: +91 ()4-312 24 f: +91 ()4-312 2411 india Ireland t: +33 ()1 247 4 f: +44 16-1796 eire Italy t: +39 1 632711 f: +39 1 6327 italia www.phenomenex.com Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com Page 8 of 8 Luxembourg t: +31 ()3-24187 f: +31 ()3-2383749 nl Mexico t: 1-8-844-226 f: 1-31-328-7768 tecnicomx@phenomenex.com The Netherlands t: +31 ()3-24187 f: +31 ()3-2383749 nl New Zealand t: +64 ()9-47891 f: +64 ()9-47892 nz Norway t: +47 81 2 f: +4 481 626 nordic Puerto Rico t: +1 (8) 41-HPLC f: +1 (31) 328-7768 Spain t: +34 91-413-8613 f: +34 91-413-229 esp Sweden t: +46 ()8 611 69 f: +4 481 626 nordic United Kingdom t: +44 ()16-1367 f: +44 ()16-1796 uk USA t: +1 (31) 212- f: +1 (31) 328-7768 All other countries Corporate Office USA t: +1 (31) 212- f: +1 (31) 328-7768 μm Minibore Columns (mm) Phases 3 x 2.1 x 2.1 1 x 2.1 x 2.1 3/pk EVO C18 A-4633-AN B-4633-AN D-4633-AN F-4633-AN AJ-9298 XB-C18 A-46-AN B-46-AN D-46-AN AJ-8782 C18 A-461-AN B-461-AN D-461-AN F-461-AN AJ-8782 μm MidBore Columns (mm) Phases x 3. 1 x 3. x 3. 3/pk EVO C18 B-4633-Y D-4633-Y F-4633-Y AJ-9297 XB-C18 B-46-Y D-46-Y F-46-Y AJ-877 C18 B-461-Y D-461-Y F-461-Y AJ-877 for 3. mm ID μm Analytical Columns (mm) Phases x 4.6 1 x 4.6 x 4.6 x 4.6 3/pk EVO C18 B-4633-E D-4633-E F-4633-E G-4633-E AJ-9296 XB-C18 B-46-E D-46-E F-46-E G-46-E AJ-8768 C18 B-461-E D-461-E F-461-E G-461-E AJ-8768 μm Semi-Preparative Columns (mm) SemiPrep Cartridges*** Phases x 1 x 1 1 x 1 EVO C18 F-4633-N G-4633-N AJ-936 C18 F-461-N G-461-N AJ-9278 for 1 mm ID μm Axia Packed Preparative Columns (mm) PREP Cartridges* Phases x 21.2 1 x 21.2 x 21.2 x 21.2 x 21.2 EVO C18 B-4633-P-AX D-4633-P-AX F-4633-P-AX G-4633-P-AX AJ-934 XB-C18 B-46-P-AX D-46-P-AX F-46-P-AX G-46-P-AX AJ-914 C18 B-461-P-AX D-461-P-AX F-461-P-AX G-461-P-AX AJ-914 for 21.2 mm ID μm Axia Packed Preparative Columns (mm) PREP Cartridges** Phases x 3 1 x 3 x 3 x 3 x 3 EVO C18 B-4633-U-AX D-4633-U-AX F-4633-U-AX G-4633-U-AX AJ-93 XB-C18 B-46-U-AX D-46-U-AX F-46-U-AX G-46-U-AX AJ-924 C18 B-461-U-AX D-461-U-AX F-461-U-AX G-461-U-AX AJ-924 ULTRA Cartridges require holder, Part No.: AJ-9 * PREP Cartridges require holder, Part No.: AJ-8223 ** PREP Cartridges require holder, Part No.: AJ-8277 *** SemiPrep Cartridges require holder, Part No.: AJ-9281 for 3 mm ID If Kinetex core-shell analytical columns do not provide at least an equivalent separation as compared to a competing column of the same particle size, similar phase and dimensions, return the column with comparative data within 4 days for a FULL REFUND. Terms and Conditions Subject to Phenomenex Standard Terms and Conditions, which may be viewed at http://www.phenomenex.com/termsandconditions. Trademarks Kinetex is a registered trademark and, Axia, and MidBore are trademarks of Phenomenex. Axia column and packing technology is patented by Phenomenex. U.S. Patent No. 7,674,383. Kinetex EVO is patented by Phenomenex. U.S. Patent Nos. 7,63,367 and 8,68,38 and foreign counterparts. 217 Phenomenex, Inc. All rights reserved. TN17_W