Sample Preparation Techniques for Biological Matrices: Finding the right balance to achieve optimal results

Similar documents
Filtration Approaches to Sample Preparation and Cleanup. Golnar Javadi Application Engineer Sample Preparation Products

Fast quantitative Forensic Analysis of THC and its Metabolites in Biological Samples using Captiva EMR- Lipid and LC/MSMS

Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates

Agilent Captiva Sample Preparation Filtration Portfolio GAUGE THE DIFFERENCE FILTRATION CAN MAKE

Reduced Ion Suppression and Improved LC/MS Sensitivity with Agilent Bond Elut Plexa

SPE and QuEChERS Method Development. Tina Chambers Christophe Deckers lent.com

Comprehensive Study of SLE as a Sample. Preparation Tool for Bioanalysis

Author. Introduction. Small Molecule Pharmaceuticals & Generics

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

Overcoming the Challenges of Sample Preparation and LC/MS/MS Method Development for Clinical Applications

Taking the Complexity out of SPE Method Development

Performance of an ultra low elution volume 96-well plate

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

LC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ

Efficient Quantitative Analysis of THC and Metabolites in Human Plasma Using Agilent Captiva EMR Lipid and LC-MS/MS

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS)

A Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids

Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE. SLE+ Prior to LC/MS-MS Analysis

Surviving Matrix Effects Experiments. Grace van der Gugten St. Paul s Hospital, Vancouver, BC, Canada

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Rapid and Robust Detection of THC and Its Metabolites in Blood

Application Note. Author. Abstract. Introduction. Food Safety

Determination of Patulin in Apple Juice Using SPE and UHPLC-MS/MS Analysis

Determination of Pharmaceutical Residues in Bovine Milk via LC MS/MS Following Solid Phase Extraction

Fig. 1: Chemical structure of arachidonic acid COOH CH 3

The Raptor HILIC-Si Column

Dr. Erin E. Chambers Waters Corporation. Presented by Dr. Diego Rodriguez Cabaleiro Waters Europe Waters Corporation 1

Authors. Abstract. Forensic Toxicology. Irina Dioumaeva, John M. Hughes Agilent Technologies, Inc.

What You Can t See Can Hurt You. How MS/MS Specificity Can Bite Your Backside

Removal of Triton X-100 from Plasma Samples Using Mixed-Mode Solid Phase Extraction (SPE)

Quantitative Determination of Drugs of Abuse in Human Plasma and Serum by LC/MS/MS Using Agilent Captiva EMR Lipid Cleanup

Mycotoxin Analysis in Infant Formula Using Captiva EMR Lipid Cleanup and LC/MS/MS

Detection of Low Level of Chloramphenicol in Milk and Honey with MIP SPE and LC-MS-MS

Extraction of Synthetic and Naturally Occurring Cannabinoids in Urine Using SPE and LC-MS/MS

Providing a Universal, One-step Alternative to Liquid-Liquid Extraction in Bioanalysis

Analysis of Cholesterol-Lowering Drugs (Statins) Using Dried Matrix Spot Technology

Overview of Matrix Effects in Bioanalysis

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

Enrichment of Phospholipids from Biological Matrices with Zirconium Oxide-Modified Silica Sorbents

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Analysis of Rosuvastatin in Dried Blood Spot and Plasma Using ACQUITY UPLC with 2D Technology

Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis

Mycotoxin Analysis in Peanut Butter Using Captiva EMR Lipid Cleanup and LC/MS/MS

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

Simplifying Solid-Phase Extraction [ OASIS SOLID-PHASE EXTRACTION PRODUCTS ]

Extraction of 25-hydroxy Vitamin D from Serum Using ISOLUTE. PLD+ Prior to LC-MS/MS Analysis

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Extraction of 11-nor-9-carboxy-tetrahydrocannabinol from Hydrolyzed Urine by ISOLUTE. SLE+ Prior to GC/MS Analysis

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

Determination of Ractopamine and Clenbuterol in Beef Samples

Secrets to Successful GC-MS/MS Pesticide Method Development

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

Simultaneous Quantitative Analysis of Total Catecholamines and Metanephrines in Urine Using CLEAN UP CCX2 and LC-MS/MS

Application Note. Abstract. Authors. Pharmaceutical

Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value

Agilent 6470 Triple Quadrupole LC/MS System and EMR-Lipid. The Combination for Confident Pesticide Quantitation. Christoph Mueller

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS

Analysis of Per- and Polyfluoroalkyl Substances (PFASs) in Biological Fluid Using a Novel Lipid Removing Sorbent and LC-MS/MS

The challenging extraction of non-polar contaminants out of a non-polar vegetable oil sample

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

Author. Introduction. Abstract

Using Hydrophilic Interaction Chromatography (HILIC) for the Retention of Highly Polar Analytes

Opiates, Opioids and Benzodiazepines, Amphetamines & Illicit Drug Forensic Analysis by LC/MS

Detection, Confirmation, and Quantification of Chloramphenicol in Honey, Shrimp and Chicken Using the Agilent 6410 LC/MS Triple Quadrupole

Ion Exchange and Reversed Phase interactions in selective Bio-SPME extractions of designer drugs

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS

Quantitative Analysis of Opiates in Urine Using RRHT LC/MS/MS. Application. Authors. Introduction. Abstract. Forensics

Simple Method (IS-MRM) to Monitor Lysophospholipids and Phospholipids During LC-MS Method Development via In-Source CID

Quantitative Determination of Drugs of Abuse in Human Whole Blood by LC/MS/MS Using Agilent Captiva EMR Lipid Cleanup

Improved Isolation and Analysis of Mycotoxins from Cereals, Beer and Wine

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases

Challenges in Developing an Ultra-Sensitive Bioanalytical Method for Ethinylestradiol in Human Plasma

Simultaneous Quantitative Analysis of Total Catecholamines and Metanephrines in Urine Using 500 MG CLEAN UP CCX2 and LC-MS/MS

Chip-Based E-Tip SPE followed by Infusion MS. Copyright by Jack Henion, 2015 Lecture 1, Page 30

Tailor made sample preparation for unusual bioanalytical research. Erik Baltussen, PhD

EASIMIP TM PATULIN Product Code: P250 / P250B

A Novel Platform of On-line Sample Pre-treatment and LC/MS/MS Analysis for Screening and Quantitation of Illicit Drugs in Urine

Analyze Barbiturates in Urine with Agilent 6430 LC/MS/MS and Poroshell 120 EC-C18

LC/MS Method for Comprehensive Analysis of Plasma Lipids

Sample Concentration and Analysis of Human Hormones in Drinking Water

Analysis of HMF by HPLC

Impact of Reversed-Phase Chiral Chromatography on the LC-MS Analysis of Drugs in Biological Fluids

Alternative Method of Hybrid SPE Sample Preparation for High Recovery LC-MS Analysis of Pharmaceutical Compounds in Plasma

Dienes Derivatization MaxSpec Kit

AbsoluteIDQ p150 Kit. Targeted Metabolite Identifi cation and Quantifi cation. Bringing our targeted metabolomics expertise to your lab.

LC/MS/MS of Buprenorphine and Norbuprenorphine in Whole Blood Using Agilent Bond Elut Plexa PCX and an Agilent Poroshell 120 Column

Development and Validation of Multiresidue Pesticide Methods at FDA/CFSAN

Mass Spectrometry Made Simple for Clinical Diagnostic Labs

Determination of Benzodiazepines in Urine by CE-MS/MS

High Throughput Workflow for Global Metabolomic Profiling of Biological Samples with RapidFire online SPE/MS system

Development and Validation of an UPLC-MS/MS Method for Quantification of Mycotoxins in Tobacco and Smokeless Tobacco Products

AbsoluteIDQ p180 Kit. Targeted Metabolite Identifi cation and Quantifi cation

Multiclass Mycotoxin Analysis in Cheese Using Agilent Captiva EMR Lipid Cleanup and LC/MS/MS

using the Agilent 7696A Sample Prep

LC/MS/MS of Trichothecenes and Zearalenone in Wheat Using Different Sample Prep Methods

Transcription:

Sample Preparation Techniques for Biological Matrices: Finding the right balance to achieve optimal results Presenter: Diana Wang Applications Engineer SPP-Support@agilent.com 1

Today s Agenda - Why sample prep - Overview of sample preparation options - Common challenges in bioanalysis applications - Sample preparation solutions to these challenges - Summary, Questions and Wrap Up 2

Biological Sample Analysis THE IMPORTANCE OF SAMPLE PREPARATION 3

Sample Analysis Workflow Diagram in Biological Sample Testing 23.5 ng/ml c-thc Sample Preparation Sample Analysis Data Handling Sample Transport Archiving Sample Collection/ Sampling Information to customer Report Generation 4

Why is Sample Preparation Required? Concentration: Target analyte(s) not concentrated enough for quantitative detection Compatibility: Sample is not compatible with or would be harmful to your chromatographic system Cleanliness: Sample matrix components will interfere with the analysis 5

Possible Effects of Biological Sample Components Issue Poor peak shapes, co-elution, no resolution Mechanical issues (particulates, blockages) Increased instrument downtime Interferences Result Difficulty in identifying, quantifying components LC/GC column lifetime issues Reduced productivity, increase in sample run time / cost Ion suppression in LC-mass spectrometry Peak integration issues Overall lower sensitivity Inability to meet detection limits 6

Striking the Right Balance in Sample Preparation Just Right Ideal Quality of Results Realistic Effort & Investment 7

Biological Sample Analysis SAMPLE PREPARATION OPTIONS 8

Sample Preparation Techniques For Today s Discussion 1. Filtration Basic particulate removal from ALL kinds of samples Useful when additional step of lipid content removal is needed 2. Liquid-Liquid Extraction Straightforward sample preparation technique Useful for in-house or commercial extraction 3. Solid supported liquid extraction (SLE) Increased productivity using liquid/liquid extraction principle and the concept of automation Ideal for aqueous sample or samples 4. Solid phase extraction (SPE) Ultra-clean sample preparation for analysis when high selectivity and sensitivity are required 9

Sample Prep Options: An Overview Direct injection Dilute & Shoot Filtration Liquid/liquid extraction (LLE, SLE) QuEChERS Solid phase extraction (SPE) MIPS and Immunoaffinity Columns Less Selective More Selective 10

Dilution (Dilute & Shoot) Simple sample dilution Advantages Fast and easy High throughput Limitations Interferences are not removed Concentration is reduced Instrument and column contamination Matrix interferences ion suppression or poor peak shapes 11

Filtration Basic sample prep method for ALL kinds of samples Can be the 1st choice of sample prep or 2nd secondary step Mechanical filtration for visible interference removal Syringe filters Syringeless filters Agilent Captiva (cartridge and 96-well plate formats) Agilent Captiva ND (cartridge and 96-well plate formats) Mechanical filtration + extraction by sorbent for lipid removal Agilent Captiva ND Lipids (cartridge and 96-well plate formats) 12

Sample Preparation: Liquid-Liquid Extraction Advantages Inorganic salts easily removed Short method development time Low cost Flexible for a variety of sample types Easy to perform Disadvantages Labor-intensive Large volumes of organics Difficult to automate Variable results Expensive, clean glassware Emulsion formation 13

Solid Supported Liquid Extraction (SLE) Extraction mechanism: same as traditional liquid/liquid extraction (LLE) Simple, time-saving process Apply aqueous sample to the solid bed Extract with water-immiscible solvent (MTBE, dichloromethane, ethyl acetate) Analyze extract or evaporate and reconstitute as needed Convert LLE methods to SLE to save time and money, and increase throughput 14

Solid-Supported LLE - Benefits No emulsions easier extractions No special glassware lower cost per sample Less time, minimal method development faster implementation Reduced technique dependence better ruggedness Increased reproducibility better results Automatable enables batch processing 15

Solid Phase Extraction (SPE) Types of SPE Reversed phase SPE Cation exchange SPE Anion exchange SPE Mixed mode SPE Specialty SPE Capabilities Very selective Highly clean samples Wide range of applicability Automation friendly Condition Load Wash Elute 16

A Typical SPE Sequence Condition the cartridge (Step 1) Apply sample (e.g. food extract, water, plasma) (Step 2) Some compounds retain First wash of the cartridge, interference removal (Step 3a) Second wash of the cartridge, additional interference removal (Step 3b) Apply a different liquid to elute (Step 4) The extract is cleaner, in a different liquid, and typically more concentrated Some sorbent technologies let you reduce the number of steps for easier, faster extractions 17

Why Choose SPE? Flexible - match a broad spectrum of sample and target compound types to different sorbents and forms Wide array of formats and sorbents for lower detection limits and longer instrument uptime from cleaner extracts Increase sample throughput with automation-friendly formats Easy adoption of methods due to high number of publications and applications Get the right answer the first time with highest accuracy and confidence Best balance of sample cleanliness, accuracy of results, and cost-per-sample 18

How do Sample Prep Options Compare? Solid Phase Extraction (Agilent Bond Elut) Often very clean, allows for trace analysis, built in concentration Potential for the most selectivity (and hence cleanliness) Investment Liquid/Solid Extraction (Agilent Chem Elut, Agilent QuEChERS) Relatively clean and inexpensive Complexity Filtration (Agilent Captiva Syringe Filters, Tubes, Plates, and Vials) Dilute and shoot (guard columns or retention gaps) Cleanliness 19

Biological Sample Analysis COMMON CHALLENGES IN BIOLOGICAL SAMPLE ANALYSIS 20

Agilent Sample Preparation Solutions Matrix Challenges Lab Goals & Needs 21

Tandem Mass Spectrometry and The Case of the Disappearing Matrix Selected ion monitoring looking at 100 fg HCB in matrix MRM s better selectivity makes the matrix disappear

Disappearing Matrix What Can Dirty Samples Do? Interference type Salt/Polar ionics Proteins/ Peptides Lyso-phosphatidylcholines Lipids and other hydrophobics Typical Elution Conditions (C18 column) At or near void with < 20% organic 10 s of column volumes at 40% - 70% organic 10 s of column volumes at 70% - 90% organic 10 s to 100 s of column volumes at > 90% organic Short term effect (single injection) Significant ion-suppression Significant ionsuppression Significant ion-suppression Some ion suppression, however, usually retained on LC column) Long term effect (multiple injections) Unknown Unknown Decreased sensitivity, Increased variability Decreased sensitivity, Increased variability Likely long term causes Ion source contamination Ion source contamination Ion source contamination, Some column build-up Ion source contamination, Column build-up 23

Challenge: Instrument Contamination Example 1 Salt build-up in LC-MS ion source from unextracted salts 24

Challenge: Instrument Contamination Example 2 Orthogonal ESI Ion Source Condition after 3000x Urine Dilute/shoot Injections Nebulizer/Sprayer Spray Shield/MS Inlet/Capillary 25

Challenge: Instrument Contamination Example 3 GC System Component Contamination with Biological Samples GC Inlet Liner GC Inlet Seal 26

Solution: Select an Agilent Sample Preparation Product Based on Interference Removal Particulates Proteins Lipids Surfactants Salts Captiva Filtration Captiva ND Captiva ND Lipids Chem Elut SLE Bond Elut SPE 27

Lipids that Cause Interference and System Cleanliness Issues R R - R m/z = 184 (+2H) m/z = 184 (+2H) phosphatidylcholine lysophosphatidylcholine Two major lipid interferences that exist during bioanalysis by LC/MS/MS. By soft ionization conditions, these two phospholipids can generate the common fragment, 184 m/z. Removal of ion suppressing lipids can be verified by monitoring 184 184 m/z transition. 28

Solution: Targeted Lipid Removal Green = ppt only Red = lipid-stripped ppt with Captiva ND Lipids MS Transition 184 184 29

Solution: SLE Extraction of Beta-Blockers in Plasma Plasma spiked with beta blockers was diluted by 2% ammonia 1:1. Load 0.3 ml of spiked & diluted plasma to VersaPlate. Apply slight vacuum to initiate flow. When sample is soaked below the top frit stop vacuum. Wait for 5 min for aqueous sample adsorption. Elute with 2 X 0.9 ml of EtOAc. Apply vacuum to have 1 2 drops per sec. After elution increase vacuum for 30 sec. Evaporate and reconstitute in 0.15 ml of 30% MeOH for LC/MS/MS analysis. 30

Beta-Blockers by SLE Chromatography Acebutolol (ISTD) Timolol Nadolol Metoprolol Propranolol Pindolol 31

Solution: Remove Proteins & Lipids Using SPE Exploit the chemistry and physical properties of Agilent Bond Elut Plexa SPE sorbent Polar and non-polar drugs bind in the SDVB hydrophobic end of the pore structure Albumin and proteins of similar size will be excluded Lipids adsorb and do not elute under normal elution conditions 32

Solid Phase Extraction of Buprenorphine and nor- Buprenorphine in Whole Blood SPE using Agilent Bond Elut Plexa PCX polymeric cation exchange Buprenorphine and norbuprenorphine were efficiently extracted from whole blood Extraction method was simple and used only 0.5 ml of whole blood Mixed-mode cation exchange SPE ensures removal of matrix and high recoveries of targets Precise, reproducible extraction with low detection limits buprenorphine at 0.2 ng/ml nor-buprenorphine at 0.2 ng/ml buprenorphine-d4 (ISTD) at 10 ng/ml nor-buprenorphine-d3 (ISTD) at 10 ng/ml 33

Challenge: Degradation of Sub-2-µm LC Column Performance Over Time 34

Solution: Filtration Extends Column Lifetime 35

Challenge: Unexplained Peaks in Sample ESI-Positive Mode 7000000 Filtered 30% MeOH by Filter W 0.2µm filter IS 6000000 5000000 Filtered 30% MeOH by Filter M PES 0.2µm filter IS 4000000 Filtered 30% MeOH by Filter P PES 0.2µm filter IS 3000000 2000000 Filtered 30% MeOH by Agilent PES 0.2µm filter IS 1000000 Unfiltered 30% MeOH IS 0 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 min 36

Solution: Use Certified Clean Filtration Products ESI-Positive Mode 7000000 Filtered 30% MeOH by Filter W 0.2µm filter IS 6000000 5000000 Filtered 30% MeOH by Filter M PES 0.2µm filter IS 4000000 Filtered 30% MeOH by Filter P PES 0.2µm filter IS 3000000 2000000 Filtered 30% MeOH by Agilent PES 0.2µm filter IS 1000000 Unfiltered 30% MeOH IS 0 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 min 37

Challenge: Sample Throughput and Productivity 100s or 1000s of samples a day to be processed Consistency and simplicity to achieve high-quality results with few repeats Limit the operator-to-operator and day-to-day variation (ruggedness) Support for automation for increased throughput and unattended operation 38

Solution: Replace Conventional Protein Precipitation with Captiva ND Lipids Centrifugation Protein Precipitation (PPT) Time (min) Captiva ND Lipids Time (min) Add 0.6 ml of MeOH and 0.2 ml of plasma sample to Captiva ND 96-well plate. Centrifuge at 10,000 RPM for 10 min. Transfer supernatant to 2 ml injection vials (if tubes were used) or a new empty 96-well plate for analysis (if plate format was used). Total time required for sample preparation Lipids WILL build up during your sequence. 5 Add 0.6 ml of MeOH and 0.2 ml of plasma sample to Captiva ND 96-well plate. 11 Mix each well with a pipette 5 times and apply vacuum for filtration. 10 Directly transfer injection plate for analysis. Total time required for sample preparation Proteins AND lipids will be removed during your sample preparation. 5 0 39

Results: Captiva ND Lipids for Beta-blockers in Plasma Acebutolol (ISTD) Timolol Nadolol Atenolol Good chromatography Propranolol Pindolol Short Run Time 40

Agilent Captiva ND and Captiva ND Lipids Simplify Sample Prep Extended column lifetime especially for UHPLC system with sub-2 µm columns Designed for high throughput via automation (cartridges or 96-well plate formats) Reduced instrument downtime/maintenance/repair Fast! No conditioning, evaporation, and reconstitution steps are required. No analyte loss during washing and evaporation steps. Reduces ion suppression caused by lipids (Captiva ND Lipids) 41

Challenge: Sample Logistics and Handling Traditional Blood Collection, Transportation, and Storage 6/25/2013

Solution: Agilent DMS Cards for Sample Collection and Storage Dried Matrix Spot (DMS) Spot. Dry. Send DMS cards in an envelope. 43

Dried Matrix Spot, DMS (Analysis) Punch DMS cards. Put punched spot in a centrifugation tube with organic solvent e.g. 80% MeOH. Add internal standard. Centrifuge. Take supernatant for analysis. Or you can take further to combine other sample prep techniques such as SPE, Captiva ND Lipids, etc.

Biological Sample Analysis SUMMARY AND WRAP UP 45

Striking the Right Balance in Sample Preparation Just Right Ideal Quality of Results Realistic Effort & Investment 46

Solution: Select an Agilent Sample Preparation Product Based on Interference Removal Particulates Proteins Lipids Surfactants Salts Captiva Filtration Captiva ND Captiva ND Lipids Chem Elut SLE Bond Elut SPE 47

Summary and Wrap-Up Biological sample analysis presents multiple challenges, both from the matrix and from the laboratory needs and goals Sample preparation is an investment that can help solve those challenges and achieve your analytical goals Matching the sample preparation approach to the challenge ensures that you are employing the right tool for the task Agilent s sample preparation options and expertise are ideally suited for bioanalysis challenges 48

Additional Resources and Application Support Reference Materials and Guides: Agilent Sample Preparation Catalog: www.chem.agilent.com/sppcatalog Agilent Sample Preparation Products www.agilent.com/chem/sampleprep Agilent Sample Preparation Products Technical Support Contact Information*: Phone: 800-227-9770, Options 3, 3, 3 Email: spp-support@agilent.com * North America 49

Acknowledgements Agilent applications chemists, product managers, and technical support colleagues who contributed to this presentation. 50

Questions? 51