Influence of cataract on image quality and macular thickness measured using spectral domain optical coherence tomography: a prospective cohort study

Similar documents
Influence of cataract and small incision cataract surgery on the macular thickness measurements: an optical coherence tomography-based study

Repeatability and Reproducibility of Macular Thickness Measurements Using Fourier Domain Optical Coherence Tomography

Evaluation of Changes of Macular Thickness in Diabetic Retinopathy after Cataract Surgery

Retinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography

Association of grade of cataract with duration of diabetes, age and gender in patients with type II diabetes mellitus

Ophthalmology. Caring For Your Eyes. Jurong Medical Centre

Optical Coherence Tomograpic Features in Idiopathic Retinitis, Vasculitis, Aneurysms and Neuroretinitis (IRVAN)

Study of clinical significance of optical coherence tomography in diagnosis & management of diabetic macular edema

Effect of Media Opacity on Retinal Nerve Fiber Layer Thickness Measurements by Optical Coherence Tomography

R&M Solutions

Ganglion cell complex scan in the early prediction of glaucoma

Retinal Nerve Fiber Layer Measurement Variability with Spectral Domain Optical Coherence Tomography

Cirrus TM HD-OCT. Details defi ne your decisions

OtticaFisiopatologica

STUDY OF EFFECTIVENESS OF LENS EXTRACTION AND PCIOL IMPLANTATION IN PRIMARY ANGLE CLOSURE GLAUCOMA Sudhakar Rao P 1, K. Revathy 2, T.

Method for comparing visual field defects to local RNFL and RGC damage seen on frequency domain OCT in patients with glaucoma.

Differences between Non-arteritic Anterior Ischemic Optic Neuropathy and Open Angle Glaucoma with Altitudinal Visual Field Defect

Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma

A spectral-domain OCT study of formerly premature children. Prat Itharat MD May 30, 2008 Vanderbilt Eye Institute Preceptor: Dr.

Comparative evaluation of time domain and spectral domain optical coherence tomography in retinal nerve fiber layer thickness measurements

OCT Angiography: The Next Step in Retinal Imaging Jonathan Zelenak D.O.

Advances in OCT Murray Fingeret, OD

Measurement of Choroidal Thickness in Normal Eyes Using 3D OCT-1000 Spectral Domain Optical Coherence Tomography

ORIGINAL ARTICLE. HIGH VOLUME CAMP SURGERIES A CLINICAL STUDY D. N. Prakash, K, Sathish, Sankalp Singh Sharma, Soujanya. K, Savitha Patil.

A Formula to Predict Spectral Domain Optical Coherence Tomography (OCT) Retinal Nerve Fiber Layer Measurements Based on Time Domain OCT Measurements

Bilateral Microphthalmos Associated with Papillomacular Fold, Severe Hyperopia and Steep Cornea

Assessment of Retinal Nerve Fiber Layer Changes by Cirrus High-definition Optical Coherence Tomography in Myopia

Corneal densitometry using Pentacam based scheimpflug imaging system: Indian rural population

Optic Disc Retinal Nerve Fiber Layer Thickness in Normal Paediatric Population of Central India

Yasser R. Serag, MD Tamer Wasfi, MD El- Saied El-Dessoukey, MD Magdi S. Moussa, MD Anselm Kampik, MD

Cirrus TM HD-OCT. Details define your decisions

STRUCTURE & FUNCTION An Integrated Approach for the Detection and Follow-up of Glaucoma. Module 3a GDx

INTRODUCTION J. DAWCZYNSKI, E. KOENIGSDOERFFER, R. AUGSTEN, J. STROBEL. Department of Ophthalmology, University Hospital Jena, Jena - Germany

To assess the glaucoma diagnostic ability of Fourier Domain Optical Coherence Tomography

Parafoveal Scanning Laser Polarimetry for Early Glaucoma Detection

Comparison of Retinal Nerve Fiber Layer Thickness between Stratus and Spectralis OCT

Diabetic Retinopathy Clinical Research Network

Visual and Anatomical Outcomes of Vitreous Surgery for Large Macular Holes

VMA at the macula resulting in VMT

Measure #191: Cataracts: 20/40 or Better Visual Acuity within 90 Days Following Cataract Surgery

Immersion Vs Contact Biometery for Axial Length Measurement before Phacoemulsification

Audit of Macular Hole Surgery, Visual Outcome Prediction on OCT Appearance of Macular Hole


Structural examina.on: Imaging

Subclinical Diabetic Macular Edema Study

For details on measurement and recording of visual acuity, refer to Annex 1. VISION INTERPRETING RESULTS ABSTRACT

OPTOMETRY RESEARCH PAPER

Optical Coherence Tomography (OCT) in Uveitis Piergiorgio Neri, BMedSc, MD, PhD Head Ocular Immunology Unit

The Effect of Pupil Dilation on Scanning Laser Polarimetry With Variable Corneal Compensation

International Journal of Scientific & Engineering Research, Volume 4, Issue 12, December ISSN

OCT Assessment of the Vitreoretinal Relationship in CSME

Structural changes of the anterior chamber following cataract surgery during infancy

The Common Clinical Competency Framework for Non-medical Ophthalmic Healthcare Professionals in Secondary Care

Glaucoma: Diagnostic Modalities

Ultrahigh Speed Imaging of the Rat Retina Using Ultrahigh Resolution Spectral/Fourier Domain OCT

Il contributo dell'angio-oct: valutazione integrata della componente nervosa e vascolare della malattia glaucomatosa

Reproducibility of Nerve Fiber Layer Thickness Measurements by Use of Optical Coherence Tomography

This policy is applicable to Commercial Products only. For BlueCHiP for Medicare, see related policy section.

tracking progression we can better manage our patients. Like any tool, any instrument you ve got to

* Şükrü Bayraktar, MD, Zerrin Bayraktar, MD, and Ömer Faruk Yilmaz, MD

Inclusion Criteria Ages eligible for study: 40 Years to 70 Years Genders eligible for study: Both

Ophthalmology. Ophthalmology Services

Clinically Significant Macular Edema (CSME)

Dr. Harvey Richman, OD, FAAO, FCOVD Diplomate American Board of Optometry Executive Committee AOA Third Party Center Founder Ask the AOA Coding

Translating data and measurements from stratus to cirrus OCT in glaucoma patients and healthy subjects

Subnormal Vision in Uneventful Cataract Surgery after 6 Weeks Hospital Based Study

Clinical Outcomes After Intravitreal Bevacizumab Injection for Diabetic Macular Edema

JMSCR Vol 06 Issue 12 Page December 2018

Spectral- and time-domain optical coherence tomography measurements of macular thickness in young myopic eyes

Comparison of the Thickness and Volume of the Macula and Fovea in Patients with Anisometropic Amblyopia Prior to and after Occlusion Therapy

2019 COLLECTION TYPE: MIPS CLINICAL QUALITY MEASURES (CQMS) MEASURE TYPE: Outcome High Priority

Clinical Use of OCT in Assessing Glaucoma Progression

Recurrent intraocular hemorrhage secondary to cataract wound neovascularization (Swan Syndrome)

JMSCR Vol. 03 Issue 08 Page August 2015

Optical Coherence Tomography Findings in Highly Myopic Eyes following Cataract Surgery

OCT Image Analysis System for Grading and Diagnosis of Retinal Diseases and its Integration in i-hospital

MEDICAL POLICY. Proprietary Information of Excellus Health Plan, Inc. A nonprofit independent licensee of the BlueCross BlueShield Association

and at the same patient encounter. Code has been deleted. For scanning computerized ophthalmic diagnostic imaging of optic nerve and retin

2018 OPTIONS FOR INDIVIDUAL MEASURES: REGISTRY ONLY. MEASURE TYPE: Outcome

Andrew J. Barkmeier, MD; Benjamin P. Nicholson, MA; Levent Akduman, MD

ANGIO OCT IMAGING OF MACULAR VASCULATURE IN DIABETIC MACULAR EDEMA BEFORE AND AFTER MACULAR SURGERY

MEDICAL POLICY. Proprietary Information of YourCare Healthcare

You can see vivid colours again after cataract management at Sankar Foundation Eye Hospital

Clinical Study Choroidal Thickness in Eyes with Unilateral Ocular Ischemic Syndrome

Overview. Macular OCT Artifact Study

Corporate Medical Policy

Citation. As Published Publisher. Version

Mariam Raouf Fadel M.B., B.Ch. M.Sc., Cairo University. A thesis. Submitted by. For partial fulfillment of. MD Degree in Ophthalmology

Learn Connect Succeed. JCAHPO Regional Meetings 2016

CLINICAL SCIENCES. Repeatability and Reproducibility of Fast Macular Thickness Mapping With Stratus Optical Coherence Tomography

Title: OCT Analysis Workshop: Interpretation of OCT printouts

Thickness Changes in the Fovea and Peripapillary Retinal Nerve Fiber Layer Depend on the Degree of Myopia

Ganglion cell analysis by optical coherence tomography (OCT) Jonathan A. Micieli, MD Valérie Biousse, MD

VISUAL OUTCOME IN DIABETIC MACULAR EDEMA AFTER GRID LASER TREATMENT

DIRECT REFERRAL OF CATARACT PATIENTS COMMUNITY OPTOMETRIST PROTOCOL AND GUIDELINES

PRIMUS 200 from ZEISS The essential OCT

Research Article Repeatability of Perimacular Ganglion Cell Complex Analysis with Spectral-Domain Optical Coherence Tomography

Available online at Pelagia Research Library. Advances in Applied Science Research, 2013, 4(6):

Visual acuity versus letter contrast sensitivity in early cataract

The Common Clinical Competency Framework for Non-medical Ophthalmic Healthcare Professionals in Secondary Care

Transcription:

International Journal of Advances in Medicine Lathika VK et al. Int J Adv Med. 2017Apr;4(2):546-550 http://www.ijmedicine.com pissn2349-3925 eissn 2349-3933 Original Research Article DOI: http://dx.doi.org/10.18203/2349-3933.ijam20171058 Influence of cataract on image quality and macular thickness measured using spectral domain optical coherence tomography: a prospective cohort study Vasu Kamaladevi Lathika*, Susan Prakash Minu, K. Skariah Charles Department of Ophthalmology, Amala Institute of Medical Sciences, Amala Nagar, Thrissur, Kerala, India Received: 04 January 2016 Accepted: 02 February 2016 *Correspondence: Dr. Vasu Kamaladevi Lathika, E-mail: lathika.vk@gmail.com Copyright: the author(s), publisher and licensee Medip Academy. This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. ABSTRACT Background: Optical coherence tomography (OCT) is one of the most useful imaging techniques in the management of retinal diseases affecting the macula. Factors affecting the image quality of OCT may affect the macular thickness and hence treatment of retinal pathologies. This study was aimed to evaluate the influence of cataract on macular scans using spectral domain OCT. Methods: The prospective study was done in 36 patients with cataract. Cataract was graded as cortical, nuclear or posterior cataracts. All patients underwent small incision cataract surgery. Pre and post-operative imaging of the macula (4 weeks after surgery) using spectral domain OCT. The signal strength and central macular thickness (CMT) measurements were made before and after the surgery and analysed statistically. Results: The majority (66.7%) of patients had posterior cataracts. A statistically significant improvement in OCT image quality (as assessed by signal strength) was noted post operatively. This was maximum for posterior cataracts (2.9), followed by cortical cataract (1.6), while nuclear cataracts had the least increase in signal strength (1.3). The in signal strength gain between posterior and nuclear cataracts was found to be statistically significant (p = 0.05). The increase in CMT was clinically significant only in 8.2% of the study population. No patient with nuclear cataract had a clinically significant increase in CMT following surgery. Conclusions: Cataract can influence OCT image quality as well as central macular thickness measurements. Both were found to be affected maximally by posterior cataracts, followed by cortical, while nuclear cataracts had the least influence. Keywords: Central macular thickness, Cataract, Optical coherence tomography, Retinal pathologies INTRODUCTION Optical coherence tomography (OCT) is a non-invasive, precise imaging technique that uses infrared rays to give accurate quantitative and qualitative information of the different layers of the retina. It has revolutionized the diagnosis and treatment of retinal pathologies including diabetic retinopathy and age related macular degeneration. Pupil size, refractive status, clarity of ocular media and dryness of ocular surface are some of the factors known to influence image quality in OCT. 1,2 Cataract being one of the leading causes of blindness in the world, contributes significantly to haziness of media which can affect OCT imaging. 3,4 Moreover, many of the retinal vasculopathies and degenerations requiring OCT occur more frequently in the elderly population, who are likely to have concurrent cataract. A better knowledge about the type of cataracts that can hamper the quality of scans can help clinicians identify cases where OCT has to International Journal of Advances in Medicine March-April 2017 Vol 4 Issue 2 Page 546

be interpreted with caution. Studies in this regard are few, mainly done in the western population and mostly focus on retinal nerve fibre thickness in optic disc scans. 5 Here in lies the relevance of the present study which aims to throw light on the exact influence of cataract morphology on the quality of OCT images of the macula, in Asian Indian population. This aim of the study was to evaluate the influence of different grades of cataracts on signal strength of spectral domain OCT images of the macula. Furthermore, the study also aimed to analyse the changes in central macular thickness (CMT) measurement following cataract extraction in different grades of cataract. The results may contribute to the ultimate goal of establishing a relationship between the type of cataract, signal strength and central macular thickness measurement using SD OCT that may enable clinicians to predict and correct for cataract induced changes in these measurements. METHODS A prospective study of 36 patients who were posted for cataract surgery in the department of Ophthalmology, Amala Institute of Medical Sciences, Kerala, India during the study period from September 2014 to November 2014. Patients with concurrent conditions which could influence OCT signal strength like pre existing opacities of ocular media other than cataract or high refractive errors were excluded. Patients with known macular pathologies were also excluded as these could influence changes in central macular thickness. The study was approved by the institutional ethics committee. All patients who were being planned for cataract surgery during the study period were approached and invited to participate in the study after obtaining informed consent. These patients underwent preoperative cataract work up including best corrected visual acuity (BCVA) measured using Snellen chart, a complete dilated slit lamp evaluation, bio microscopic examination of fundus using 90D lens, assessment of IOL power, tonometry and syringing. Cataract was assessed and graded depending on the highest score using the lens opacities classification system III (LOCSIII) scoring system. 6 If the score was >NO3 NC3 and <C3 and P3, the cataract was grade as nuclear. If the score was >C3 it was graded as cortical and if it was >P3 it was considered posterior. If the score was <NO3 NC3, the highest C or P score was used to grade the cataract Thus, based on LOCS scores, patients were divided into three groups. Those with predominantly posterior cataract Those with nuclear cataract Those with cortical cataract Spectral domain OCT images of macula of all patients were obtained preoperatively through dilated pupils using CIRRUS HD-OCT (Carl Zeiss, Germany), using the macular cube mode. The data was obtained from a threedimensional dataset composed of 512 A-scans derived from 128 B-scans that cover a 6 6 mm area centered on the fovea. All patients underwent uncomplicated small incision cataract surgery. Postoperative regimen included oral antibiotics, topical antibiotics, anti-inflammatory and steroid drops. OCT scans were repeated during follow up visit, one month after surgery. Signal strength is known to be a reliable indicator of image quality in spectral domain OCT. 7 Hence, in order to assess image quality after cataract surgery, signal strength of the preoperative and post operative OCT images were recorded and noted. Central macular thickness values before and after surgery were also noted. The data was subjected to statistical analysis using SPSS (v23, IBM, CA, USA). Paired t test was used to determine the influence of grade of cataract on OCT signal strength and CMT measurement before and after cataract surgery. Further comparison analysis between the grades of cataract was done using independent sample t test. A p-value of less than 0.05 was taken as statistically significant. RESULTS Of the 36 eyes included in the study, majority had posterior cortical cataract (20/36). There were eight eyes with nuclear and eight with cortical cataract. Cataract and OCT image quality The OCT image quality as assessed by signal strength improved following cataract surgery (Table 1). The mean OCT signal strength of the group preoperatively was OCT was 4.91, which improved to 7.19 postoperatively. This of 2.27 was found to be statistically significant (p = 0.0001). Subgroup analysis of each grade of cataract showed that signal strength improved following cataract surgery in all grades of cataract to a statistically significant extent (Table 2). The gain in OCT signal strength post operatively was maximum for posterior cataracts (2.9, p=0.0001)), followed by cortical cataract (1.6, p=0.024), while nuclear cataracts had the least increase in signal strength (1.3, p = 0.028). Of these, the between posterior and nuclear cataracts was found to be statistically significant (p = 0.05) using the independent sample t-test (Table 3). Cataract and central macular thickness measurements It was analysed whether cataract affected CMT measurements by noting the in values between pre-operative and post-operative OCT scans. Like OCT signal strength, the average CMT of the study group was International Journal of Advances in Medicine March-April 2017 Vol 4 Issue 2 Page 547

also found to increase following cataract surgery. The mean preoperative CMT was 247.667 microns which increased to 256.417 four weeks after surgery. Thus there was a mean increase of 8.7 microns in mean CMT of the study group postoperatively, which amounted to a percentage increase of 3.48% from the baseline pre operative mean CMT (Table 4). Table 1: Comparison of mean optical coherence tomography (OCT) signal strength of the study group before and after cataract surgery. Mean OCT signal strength Mean SS Standard Std. error N of study group deviation mean Pre operative-4.917 2.27 36 1.6966 0.2828 Postoperative-7.194 36 1.4894 0.2482 Paired t test. P value* 0.0001 Table 2: Comparison of signal strength before and after cataract surgery in different grades of cataract. Cataract grade Cortical Nuclear Posterior *Independent sample t test. Mean signal strength N Std. deviation P value* 1.6 8 1.6850 0.024 8 2.0529 1.3 8 1.1952 8 1.0607 0.028 2.9 20 1.8468 20 1.3179 0.0001 Table 3: Comparison of mean optical coherence tomography (OCT) signal strength before and after cataract surgery between the different grades of cataract. A: posterior cortical and nuclear. Mean OCT SS Std. deviation Std. error mean P value* Posterior 20 2.900 1.9708 0.4407 0.058 Nuclear 8 1.375 1.4079 0.4978 B. Posteriorcortical and cortical. Mean OCTSS Std. deviation Std. error mean P value Posterior 20 2.900 1.9708 0.4407 0.117 Cortical 8 1.625 1.5980 0.5650 C. Cortical and nuclear. Mean SS Std. deviation Std. error mean P value Nuclear 8 1.375 1.4079 0.4978 0.745 Cortical 8 1.625 1.5980 0.5650 *Independent sample t test This was found to be statistically significant (p = 0.007, paired t test). However, only 8.2% of the study population showed clinically significant increase in CMT (more than 10% from pre-operative baseline scan was taken as clinically significant) on repeat OCT scans 4 weeks post operatively (Figure 1). 8 Analyzing the distribution of cataracts in eyes where such a significant increase was detected, we found that International Journal of Advances in Medicine March-April 2017 Vol 4 Issue 2 Page 548

majority (66.7%) were eyes with posterior cataracts, while 33.3% were cortical cataracts (Figure 2). No patient with nuclear cataract had a clinically significant increase in CMT following cataract surgery. Table 4: Change in central macular thickness (CMT) before and after cataract surgery (4 weeks post surgery). N Mean CMT Standard deviation Pre-operative-247.667 microns 25.19 36 Postoperative-256.417 microns 18.15 *Independent sample t test. Mean CMT 8.7 microns 3.48 % CMT increase wks P value* 0.007 3(8%) 33(92%) <10 10 Figure 1: Percentage distribution of clinically significant increase in central macular thickness (by >10%) in the study group 4 weeks post operatively. disc mode and not in macular scan acquisition mode. 3 This could be due to the younger average age and milder cataracts in their study compared to ours. Further analysis revealed that posterior cataracts affected signal strength maximum followed by cortical and then nuclear. Of these, the between posterior and nuclear cataracts was found to be statistically significant. Literature review suggests that this could be due to nuclear cataracts causing only infrared absorption and not much light scattering. 9 So, though this may cause the back reflected signal to be less intense, it does not distort the light beam. In contrast, it is hypothesised that posterior cortical cataracts or cortical cataracts close to visual axis, affect the incident and back reflected light beams more by scattering, thus distorting the OCT image early on. 2(67%) 1(33%) C PC Studies have shown significant s in CMT with improving OCT signal strength, with absolute variations of around 5 microns for macular scans. 10 Our study found that when measured four weeks after cataract extraction, there was a mean increase of 8.7 microns in central macular thickness, which amounted to a percentage increase of 3.48% from the baseline pre-operative mean central macular thickness. This was statistically significant (p = 0.007). But, a clinically significant increase of more than ten percent from baseline CMT occurred only in 8.3% of the study population. Figure 2: Distribution of cataracts in the group with clinically significant increase in post operative central macular thickness. DISCUSSION Our study showed that SD OCT signal quality as assessed by signal strength of macular scans improved to a statistically significant extent following cataract surgery (p = 0.0001), implying that cataract does affect clarity of macular scan image acquisition. This observation is in concurrence with the study by Velthovan et al who found that SD OCT image quality was influenced by the cataracts. 9 However, a study by Na JH et al found that cirrus OCT scan quality varied with cataract only in optic Though increase in macular thickness following cataract extraction is well documented, literature is limited on the influence of the grade of cataract upon CMT measurement using SD OCT. 11 Hence, we further analysed the type of cataracts which showed a clinically significant of more than 10% from baseline in macular thickness one month following cataract extraction. Our study revealed that all such patients had either cortical (50%) or posterior (50%) cataracts. No patient with nuclear cataract showed a significant increase in central macular thickness after cataract surgery. This fact could be explained by our earlier observation that nuclear cataracts were found to have minimal effect on OCT image quality/signal strength too. Our observations concur with the study by Van International Journal of Advances in Medicine March-April 2017 Vol 4 Issue 2 Page 549

Velthoven et al which showed that OCT measurements can differ after removal of the cataract, more so in predominantly posterior cataracts. 9 CONCLUSION Cataract surgery resulted in a statistically significant increase in both signal strength and central macular thickness measured using macular scan mode of spectral domain OCT. However, the increase in central macular thickness was clinically significant in only a small percentage of the study group (8.3%), majority of whom had posterior cataracts. The improvement in OCT signal strength and clinically significant increase in central macular thickness were maximum following removal of posterior cataracts, followed by cortical and nuclear cataracts. Hence it is recommended that macular thickness variations measured using SD OCT should be interpreted with caution, more so in patients who have undergone extraction of posterior cataracts, as compared to nuclear cataracts. ACKNOWLEDGEMENTS Authors would like to thank Mrs. Gini, Assistant Professor of Statistics and Mr. Vidhu M. Joshi, Biostatistician, Department of Community Medicine, Amala Institute of Medical Sciences, Amala Nagar, Thrissur, Kerala, India for the valuable help with statistical analysis. Funding: No funding sources Conflict of interest: None declared Ethical approval: The study was approved by the institutional ethics committee REFERENCES 1. Smith M, Frost A, Graham CM, Shaw S. Effect of pupillary dilatation on glaucoma assessments using optical coherence tomography. Br J Ophthalmol. 2007;91:1686-90. 2. Stein DM, Wollstein G, Ishikawa H, Hertzmark E, Noecker RJ, Schuman JS. Effect of corneal drying on optical coherence tomography. Ophthalmology. 2006;113:985-91. 3. Na JH, Sung KR, Lee Y. Factors associated with the signal strengths obtained by spectral domain optical coherence tomography. Korean J Ophthalmol. 2012;26:169-73. 4. Darma S, Kok PH, Berg TJ, Abràmoff MD, Faber DJ, Hulsman CA, Zantvoord F, Mourits MP, Schlingemann RO, Verbraak FD. Optical density filters modeling media opacities cause decreased SD-OCT retinal layer thickness measurements with inter- and intra-individual variation. Acta Ophthalmol. 2015;93:355-61. 5. Cheung CY Leung CK Lin D. Relationship between retinal nerve fiber layer measurement and signal strength in optical coherence tomography. Ophthalmology. 2008;115:1347-51. 6. Chylack LT Jr, Wolfe JK, Singer DM, Leske MC, Bullimore MA, Bailey IL, Friend J, Mccarthy D, Wu SY. The lens opacities classification system III. Arch Ophthalmol.1993;111:831-6. 7. Rao HL, Addepalli UK, Yadav RK, Choudhari NS, Senthil S, Garudadri CS. Factors affecting the ability ofthe spectral domain optical coherence tomograph to detect photographic retinal nerve fiber layer defects. PLoS One. 2014;9:116-7. 8. Browning DJ, Fraser CM, Propst BW. The variation in optical coherence tomography measured macular thickness in diabetic eyes without clinical macular edema. Am J Ophthalmol. 2008;145:889-93. 9. Velthoven ME, Linden MH, Smet MD, Faber DJ, Verbraak FD. Influence of cataract on optical coherence tomography image quality and retinal thickness. Br J Ophthalmol. 2006;90:1259-62. 10. Samarawickrama C, Pai A, Huynh SC, Burlutsky G, Wong TY, Mitchell P. Influence of OCT signal strength on macular, optic nerve head and retinal nerve fiber layer parameters invest. Ophthalmol Vis Sci. 2010;51:4471-5. 11. Gharbiya M, Cruciani F, Cuozzo G, Parisi F, Russo P, Abdolrahimzadeh S. Macular thickness changes evaluated with spectral domain optical coherence tomography after uncomplicated phaco emulsification. Eye. 2013;27:605-11. Cite this article as: Lathika VK, Minu SP, Charles KS. Influence of cataract on image quality and macular thickness measured using spectral domain optical coherence tomography: a prospective cohort study. Int J Adv Med 2017;4:546-50. International Journal of Advances in Medicine March-April 2017 Vol 4 Issue 2 Page 550