Learning experience with transapical aortic valve implantation the initial series from Leipzig

Similar documents
The learning curve associated with transapical aortic valve implantation

Igor Palacios, MD Director of Interventional Cardiology Massachusetts General Hospital Professor of Medicine Harvard Medical School

CIPG Transcatheter Aortic Valve Replacement- When Is Less, More?

TAVI- Is Stroke Risk the Achilles Heel of Percutaneous Aortic Valve Repair?

The surgeon s role in transcatheter aortic valve implantation (TAVI)

RANDOMISED TRIALS TAVI WITH SAVR STEPHAN WINDECKER AORTIC VALVE DISEASE COMPARING

2/28/2010. Speakers s name: Paul Chiam. I have the following potential conflicts of interest to report: NONE. Antegrade transvenous transseptal route

Measuring the risk in valve patients Lessons learnt from the TAVI story? Bernard Iung Bichat Hospital, Paris, France

TAVI: Transapical Procedures

Prof. Dr. Thomas Walther. TAVI in ascending aorta / aortic root dilatation

Transcatheter Aortic Valve Implantation. SSVQ November 23, 2012 Centre Mont-Royal 15:40

The Role of TAVI in high-risk and normal-risk Patients

Results of Transapical Valves. A.P. Kappetein Dept Cardio-thoracic surgery

Transcatheter Aortic Valve Replacement: Current and Future Devices: How do They Work, Eligibility, Review of Data

Post-TAVI Cerebral Embolisms and Potential Protection Means

Transcatheter Aortic Valve Implantation Present Status and Perspectives

TAVR for low-risk patients in 2017: not so fast.

Are Heart Valve Referral Centers Feasible in Latin America?

Transapical aortic valve implantation - The Leipzig experience

Transcatheter aortic valve replacement with the SAPIEN 3 valve: preparing the field for the final expansion

Results of Transfemoral Transcatheter Aortic Valve Implantation

TAVR in 2017 What we know? What to expect?

Extension to medium and low risk patients? Friedrich Eckstein University Hospital Basel

3 years after introduction of TAVI in QEH. Michael KY Lee On Behalf of QEH TAVI Heart Team Queen Elizabeth Hospital Hong Kong

Patient selection for transcatheter aortic valve implantation (TAVI) in South Africa

Incorporating the intermediate risk in Transcatheter Aortic Valve Implantation (TAVI)

The advent of transcatheter aortic valve implantation. Vascular Complications Among Patients. cover story

Transcatheter Aortic Valve Implantation (TAVI)

Establishing a New Path Forward for Patients With Severe Symptomatic Aortic Stenosis THE PARTNER TRIAL CLINICAL RESULTS

Alternate Vascular Access for TAVR. Gian Paolo Ussia Campus Bio-medico University, Rome Italy

1-YEAR OUTCOMES FROM JOHN WEBB, MD

TAVR: Review of the Robust Data from Randomized Trials

Indication, Timing, Assessment and Update on TAVI

Percutaneous Aortic Valve Implantation. Core-Valve and Cribier-Edwards Update

Percutaneous Treatment of Valvular Heart Diseases: Lessons and Perspectives. Bernard Iung Bichat Hospital, Paris

Accepted Manuscript. Sixteen Years Later and the Debate for TAVR or SAVR Remains Controversial. Saina Attaran, MD, Vinod H.

Neal Kleiman, MD Houston Methodist DeBakey Heart and Vascular Institute

A new option for the Diagnosis and Management of Valvular Heart Disease. Oregon Comprehensive Valve Center

Aortic valve implantation using the femoral and apical access: a single center experience.

Percutaneous Aortic Valvuloplasty: Long-Term Survival

Peri-operative results and complications in 15,964 transcatheter aortic valve implantations from the German Aortic valve RegistrY (GARY)

The Heart Team and the minimalist approach to TAVR today Is there a conflict? G T Stavridis MD FETCS Onassis Cardiac Surgery Ctr.

Aortic valve calcium load before TAVI: Is it important?

First Transfemoral Aortic Valve Implantation In Bulgaria - Crossing The Valve With The Device Is Not Always

Transcatheter Aortic Valve Replacement TAVR

TAVR and Cardiac Surgeons

TRANSCATHETER AORTIC VALVE IMPLANTATION: PSCC EXPERIENCE DR HUSSEIN ALAMRI PSCC RIYADH

Aortic Stenosis Background and Breakthroughs in Treatment: TAVR Update

Transcatheter Valve Replacement: Current State in 2017

PARTNER 2A & SAPIEN 3: TAVI for intermediate risk patients

Transapical aortic valve implantation at 3 years

The Transaortic Approach for Transcatheter Aortic Valve Replacement Initial Clinical Experience in the United States

Establishing the New Standard of Care for Inoperable Aortic Stenosis THE PARTNER TRIAL COHORT B RESULTS

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

Aortic Valve Implantation

TAVI: Nouveaux Horizons

RCSIsmjoriginal article

Percutaneous aortic valve replacement should NOT be preferred therapy for aortic stenosis

Transcatheter aortic valve implantation for severe aortic stenosis a new paradigm for multidisciplinary intervention: A prospective cohort study

Valve Disease in Patients With Heart Failure TAVI or Surgery? Miguel Sousa Uva Hospital Cruz Vermelha Lisbon, Portugal

Aortic stenosis (AS) remains the most common

Evolving and Expanding Indications for TAVR

Strokes After TAVR. Ioannis Iakovou, MD, PhD. Interventional Cardiology Onassis Cardiac Surgery Center

Aortic Stenosis: Open vs TAVR vs Nothing

Strokes After TAVR Reasons for Declining Frequency

TAVI EN INSUFICIENCIA AORTICA

Transcatheter Aortic Valve Replacement

Transcatheter aortic valve implantation and pre-procedural risk assesment

Transcatheter Aortic Valve Implantation Management of risks and complications

Prevention and Management of Vascular Complications Related to Transcatheter Aortic Valve Implantation

TAVR IN INTERMEDIATE-RISK PATIENTS

Aortic Stenosis: Interventional Choice for a 70-year old- SAVR, TAVR or BAV? Interventional Choice for a 90-year old- SAVR, TAVR or BAV?

Le TAVI pour tout le monde?

Update 2012 Herzchirurgie

New Cardiovascular Devices and Interventions: Non-Contrast MRI for TAVR Abhishek Chaturvedi Assistant Professor. Cardiothoracic Radiology

Transcatheter Aortic Valve Replacement with a Self-Expanding Prosthesis or Surgical Aortic Valve Replacement in Intermediate-Risk Patients:

Late failure of transcatheter heart valves: An open question

Valve Replacement without a Scalpel Transcatheter Aortic Valve Replacement (TAVR) Charles T. Klodell, M.D.

JACC: CARDIOVASCULAR INTERVENTIONS VOL. 5, NO. 5, PUBLISHED BY ELSEVIER INC. DOI: /j.jcin

Minimalist Transcatheter Aortic Valve Replacement (MA-TAVR)

Prince Sultan Cardiac Center Experience Riyadh, Saudi Arabia

TAVR 2018: TAVR has high clinical efficacy according to baseline patient risk! ii. Con

Transcatheter aortic valve replacement (TAVR) has

A comprehensive review of the PARTNER trial

TAVR-Update Andrzej Boguszewski MD, FACC, FSCAI Vice Chairman, Cardiology Mid-Michigan Health Associate Professor Michigan State University, Central

Sotirios N. Prapas, M.D., Ph.D, F.E.C.T.S.

Minimally invasive aortic valve surgery: new solutions to old problems.

Results of Transfemoral or Transapical Aortic Valve Implantation Following a Uniform Assessment in High-Risk Patients With Aortic Stenosis

TAVI: The Real Deal? Marc Pelletier, MD Head, Department of Cardiac Surgery New Brunswick Heart Centre

Valvular heart disease poses a rising public health

Transcatheter Aortic Valve Implantation (TAVI): Current Evidence

TAVI: 10 Years After the First Case Low-Risk and High-Risk Patients What are the Limits? Dr Bernard Prendergast DM FRCP FESC John Radcliffe Hospital

Transcatheter Valve-In-Valve Implantation for Failed Balloon-Expandable Transcatheter Aortic Valves

Summary Transcatheter aortic valve implantation: Evaluation of the evidence and synthesis of organizational issues

AVR with Sutureless Valves State of the Art

TAVR y Enfermedad Coronaria. Mauricio G. Cohen, MD, FACC, FSCAI Director, Cardiac Catheterization Lab Associate Professor of Medicine

TAVI After PARTNER-2 : The Hamilton Approach

A review of the complications associated with Transcatheter Aortic Valve Implantation.

Technique of Transcatheter Aortic Valve Implantation

Effect of Availability of Transcatheter Aortic-Valve Replacement on Clinical Practice

Transcription:

Editorial Learning experience with transapical aortic valve implantation the initial series from Leipzig Jörg Kempfert, Thomas Walther Kerckhoff Clinic Bad Nauheim, Germany Corresponding to: Jörg Kempfert, MD. Kerckhoff Clinic Bad Nauheim, Benekestrasse 2-8, 61231 Bad Nauheim, Germany. Email: kempfertj@gmail.com. Submitted Oct 21, 2012. Accepted for publication Nov 29, 2012. DOI: 10.3978/j.issn.2223-3652.2012.11.05 Scan to your mobile device or view this article at: http://www.thecdt.org/article/view/1250 Since the first successful transcatheter aortic valve implantation (TAVI) back in 2002 (1), the field of TAVI has seen a rapid development. Soon, two main options in regard to the access for valve delivery evolved. With the transfemoral route (TF) the common femoral artery is entered after surgical dissection or percutaneously using an endovascular closure device. The transcatheter valve is then delivered in a retrograde fashion. The antegrade option takes advantage of the close proximity between left ventricual apex and the aortic valve (TA). After an anterolateral minithoracotomy the apex is exposed, secured by purse-string sutures and valve implantation is performed in an antegrade manner. Recently other alternative access options have gained increasing interest. One is the transsubclavian access (TS) the other uses the distal ascending aorta (TAo). However, the transapical approach remains the only antegrade one. The others can be subsumized as endovascular approaches being all retrograde in nature. The manuscript by Holzhey et al. (2) reports the cumulative experience with the antegrade transapical TAVI technique to treat elderly high-risk patients suffering from severe symptomatic aortic valve stenosis. The center was one of the very first to implement the new TA-AVI technique from Leipzig, Germany. The series reported here represents today one of the largest single center experiences worldwide including the very early pioneering phase. Bearing this special nature of the dataset in mind the experience highlights several key issues related to the development of the still young TAVI technique. The TAVI explosion The authors provide insight into the development of the case load of isolated aortic valve replacement (AVR) procedures over time at their institution. During the initial pioneering phase the number of TAVI procedures can be interpreted as an add-on to the overall AVR case load (until 2008), obviously some of the patients were not referred previously. As stated by the authors, in the following two years, the reputation of the center gained with TAVI procedures even led to an increase in the total number of AVR cases performed conventionally. During the last two years however, a slight decrease of conventional AVR procedures in favour of TAVI can be noticed. This would most likely even be more obvious if combined cases (AVR + CABG) would be analysed as today an increasing number of TAVI procedures are performed after interventional treatment of coronary artery disease (PCI). In addition, one would expect a significant increase of conventional AVR cases over time due to the overall aging population in Germany. The development observed herein within a single center which was involved in TAVI very early may precede the overall development in Germany: a similar trend towards more TAVI while having stable numbers of conventional AVR procedures was observed in 2011 (3) and there may be a further development in 2012 (~40% TAVI of all AVR procedures). In the past, the surgical community has seen the development of other minimally invasive new techniques. For example, the introduction of off-pump coronary surgery (OPCAB), minimally-invasive access (MIS) AVR and MIS mitral valve surgery. Although for all these techniques there is today clear evidence available proving either superiority or at least demonstrating a comparable safety profile with similar functional outcome compared

E8 Kempfert and Walther. Learning experience with TAVI to conventional surgery, general adoption has been much slower. According to data of the German Cardiothoracic Society (2), in 2010 the rate of OPCAB was 14.2%, MIS mitral procedures 38.6% and MIS AVR 12.5%, only. So why took the adoption of TAVI place much faster despite the fact that there is a lack of evidence proving clear superiority of the technique and functional results are often not perfect (paravalvular leaks, requirement for pacemaker implantation)? It seems that TAVI in Germany fulfils all required key driving factors: (I) From a patient s perspective: offers a less invasive option; (II) From a physician s perspective: exiting new procedure, offering new research areas, avoids complex and tedious procedures (i.e. re-do AVR after previous CABG, patients with calcified aorta); (III) From an industry perspective: profitable market expectations; (IV) Almost unrestricted and sufficient reimbursement by insurance companies. A similar TAVI explosion can be observed in other countries but only when reimbursement is liberal. Whether the indications for TAVI are justified in all cases has to be questioned given the exponential growth of implantation numbers. We clearly recommend to follow the well documented recommendations of the medical societies. It has to be highlighted that within the series of TA procedures presented by the Leipzig group no indication/ risk creeping is visible with a mean STS-Score of 11.4% and a mean age of the patients of 81.5 years. Thus, the authors have to be congratulated for achieving results that compare favourable to other series with lower risk profiles. A word of caution: surgical AVR still the gold standard Although TAVI is a very attractive and viable alternative providing a clear benefit for selected high-risk patients (i. e. porcelain aorta, previous CABG, truly frail patients), surgical (minimally-invasive access) AVR is without doubt still the gold standard for younger lower risk patients as outcome is unmatched yet and functional results including known durability of valves and absence of paravalvular leaks is of utmost importance for younger patients. Even for octogenarians outcome after surgical AVR is probably better than often assumed (4). However, the surgical community most likely has to embrace minimally-invasive access (MIS) AVR more aggressively to compete with TAVI in the future. Several single center series report excellent outcomes in elderly selected patients using MIS AVR techniques. The MIS approach might even have a beneficial impact on survival in these elderly patients (5). The future of the Heart Team concept One positive side effect of TAVI, as mentioned by the authors, is the development of the Heart Team concept in many centers. In addition to future randomized trials required to assess the value of TAVI especially in regard to so called moderate risk patients, the Heart Team eventually together with insurance companies will be the only gate keepers in order to provide best care for each individual patient. In addition, the Heart Team concept ensures optimal patient safety combining the core skills of interventional cardiology (PCI, wire skills) and cardiac surgery (conversion to open surgery, cardiopulmonary bypass (CBP), broad experience with regard to valve pathologies and treatments). As mentioned by the authors severe complication cannot always anticipated and although rare in general (requirement for CBP 4%, conversion to open surgery 2.5%) clearly require the presence of a full Heart Team. Today, TAVI cannot be considered as a pure cath lab procedure. The active involvement of surgeons especially in TF cases (joint treatment and surgeons implanting transfemoral) is critical to maintain surgical interest and thereby to ensure patient safety. Current European guidelines clearly indicate the absence of a Heart Team and no cardiac surgery on the site has to be considered as an absolute contraindication for TAVI (6). The TF-first selection reality Holzhey et al. report excellent outcome using the antegrade TA approach. The results presented compare even favourable to current outcomes from real-world registries using a TF approach when taking into account risk profiles. The authors report a 30-day mortality of 9.6% in a truly high-risk patient subset (loges I 29.7%) including the very early pioneering phase. The French national registry (FRANCE) reported 30-day mortality rates using a TF access with different valve types ranging between 8.4% and 15.1% in presence of a risk score defined by a mean loges I of 24.7-25.6% (7). Similar results have been reported within a German multicentre registry where the vast majority of patients were treated by a retrograde TF approach (95.6% TF). 30-day mortality was 12.4% with a mean loges I of 20.5% only (8). When comparing these results the conclusion should not be that TA leads to better results than TF. However,

Cardiovascular Diagnosis and Therapy, Vol 2, No 4 December 2012 it becomes obvious that a TF first selection strategy is not supported by any scientific evidence. In case of comparable risk profiles the TA approach will lead to as good results as the retrograde TF approach as it has been shown within the Canadian multicentre registry (9). Hence, we suggest a more balanced case distribution especially in regard to the evident advantages of the antegrade TA approach. Due to the short distance over the wire the TA access offers unmatched device control and facilitates most precise valve positioning. As presented at the most recent TCT conference (2012, Miami FL, USA) a subgroup analysis of the FRANCE registry revealed that a non-tf approach is an independent protective factor leading to significantly lower rates of relevant ( 2+) paravalvular leaks most likely due to the fact of better axial alignment with a more direct approach. These data confirm the excellent results reported by the Leipzig group in regard to residual paravalvular leaks. They report a rate of 2+ leaks in 5.2% and >2+ in 0.5% only. Major access site related complications associated to a TF approach have been reported quite frequently (15.3%) and have been identified as an independent predictor for mortality (10). New generation TF devices will require lower profile sheaths which hopefully will result in lower rates of major vascular complications however only if this technical advancement will be used to improve safety and not to further push anatomical limits of the TF access. Consistent to lessons learned from CABG surgery, the TA approach facilitates an almost no-touch technique in regard to the ascending aorta and the aortic arch. Hence, the theoretical risk of stroke should be very low even in case of significant calcifications. Recently, a large metaanalysis confirmed this theory with lowest stroke rate in the TA group despite higher risk profiles (11). Consistently, Holzhey et al. report a peri-procedural stroke rate of 2.1% only. However, they also describe the occurrence of delayed strokes. The phenomenon of these delayed strokes is poorly understood yet and definitively require further research (12). In summary, most centers follow a TF-first selection process potentially due to the idea that a TF approach might be less invasive and subsequently might lead to better outcomes. However, this assumption is not supported by any scientific evidence in the first place. This typically results in significantly higher risk profiles in the TA cohort ( calcified left overs ). Thus, TA outcome and mid-term survival will then look inferior in registries or randomized trials following such a TF first strategy due to higher risk E9 profiles (comparison of oranges and apples ). A well-known example is the PARTNER A trial (13) or the European SOURCE registry (14). Unfortunately, in a second step these outcome differences are then often used to justify the initial TF-first strategy. The TA Leipzig experience demonstrates clearly that the antegrade TA approach can lead to excellent outcomes despite a substantial risk profile of patients. In this context it is important to mention that this is not only true for one single German center but others [Berlin experience (15), Heidelberg experience (16)] also reporting similar promising results associated with the TA access. The learning curve One of the most interesting details reported in the manuscript by Holzhey et al. is the observed learning curve. The authors clearly demonstrate a survival benefit for those patients treated after the very first 120 procedures. The initial learning curve has been published in detail elsewhere (17). Several factors most likely contributed to the improved outcome: team building, patient selection, procedural refinements, device refinements and incorporation of advanced imaging [CT-based valve sizing, C-arm angulation based on the DynaCT (18)]. Especially the CUSUM analysis of the observed learning curve as provided by the authors will most likely stimulate further discussion. It seems that only after a total of 200 procedures the curve reaches a plateau followed by improved outcome. Although of utmost interest this observation has to be interpreted with caution and most likely cannot be generalized to centers who just recently initiated or are just about to build a TAVI program. The Leipzig learning experience summarizes the individual (center or operator specific) learning curve as well as the global learning experience that was pronounced in the early pioneering phase. As mentioned by the authors, today very well structured TAVI training programs are available including professional proctoring during the early cases. Thus, today s learning curve might be much steeper. On the other hand only centers with a substantial TAVI case load will be able to provide most optimal results. Hence, thoughts treatment of TAVI at higher-volume heart centers might be justified. Perspective The field of TAVI has seen an exponential development over the last few years. The Leipzig TA experience published in

E10 Kempfert and Walther. Learning experience with TAVI this issue provides insights into a unique dataset as it covers the early pioneering phase as well as latest developments. The outcomes reported herein are very well comparable to results from registries using a TF approach. Several topics today are still under discussion including the issue which access to choose when and the impact of learning curves. Several new TAVI devices will become commercially available soon in addition to technical refinements of the systems that were established for some longer time. Overall, several issues associated with the still young TAVI technology has to be solved prior to further liberalization of indications. This includes the problem of relevant paravalvular leaks known to negatively impact survival, the requirement of pacemaker implantations, unknown durability of the valves and the rate of major vascular complications associated mainly with the TF approach as well as a better understanding of strokes after TAVI. In this context it is critical to note that despite the on-going TAVI explosion surgical (minimally-invasive) AVR still leads to unmatched outcome in younger lower risk patients. Acknowledgements Disclosure: The authors declare no conflict of interest. References 1. Cribier A, Eltchaninoff H, Bash A, et al. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation 2002;106:3006-8. 2. Holzhey DM, Hänsig M, Walther T, et al. Transapical aortic valve implantation - The Leipzig experience. Ann Cardiothorac Surg 2012;1:129-37 3. Gummert JF, Funkat AK, Beckmann A, et al. Cardiac surgery in Germany during 2010: a report on behalf of the German Society for Thoracic and Cardiovascular Surgery. Thorac Cardiovasc Surg 2011;59:259-67. 4. Vasques F, Messori A, Lucenteforte E, et al. Immediate and late outcome of patients aged 80 years and older undergoing isolated aortic valve replacement: a systematic review and meta-analysis of 48 studies. Am Heart J 2012;163:477-85. 5. Grossi EA, Schwartz CF, Yu PJ, et al. High-risk aortic valve replacement: are the outcomes as bad as predicted? Ann Thorac Surg 2008;85:102-6; discussion 107. 6. Vahanian A, Alfieri O, Andreotti F, et al. Guidelines on the management of valvular heart disease (version 2012): The Joint Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Eur Heart J 2012;33:2451-96. 7. Eltchaninoff H, Prat A, Gilard M, et al. Transcatheter aortic valve implantation: early results of the FRANCE (FRench Aortic National CoreValve and Edwards) registry. Eur Heart J 2011;32:191-7. 8. Zahn R, Gerckens U, Grube E, et al. Transcatheter aortic valve implantation: first results from a multi-centre realworld registry. Eur Heart J 2011;32:198-204. 9. Rodés-Cabau J, Webb JG, Cheung A, et al. Transcatheter aortic valve implantation for the treatment of severe symptomatic aortic stenosis in patients at very high or prohibitive surgical risk: acute and late outcomes of the multicenter Canadian experience. J Am Coll Cardiol 2010;55:1080-90. 10. Généreux P, Webb JG, Svensson LG, et al. Vascular complications after transcatheter aortic valve replacement: insights from the PARTNER (Placement of AoRTic TraNscathetER Valve) trial. J Am Coll Cardiol 2012;60:1043-52. 11. Eggebrecht H, Schmermund A, Voigtlander T, et al. Risk of stroke after transcatheter aortic valve implantation (TAVI): a meta-analysis of 10,037 published patients. EuroIntervention 2012;8:129-38. 12. Kempfert J, Walther T. Interventional cardiology: Delayed stroke after TAVI--the role of new-onset AF. Nat Rev Cardiol 2012;9:129-30. 13. Smith CR, Leon MB, Mack MJ, et al. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med 2011;364:2187-98. 14. Thomas M, Schymik G, Walther T, et al. Oneyear outcomes of cohort 1 in the Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) registry: the European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve. Circulation 2011;124:425-33. 15. Pasic M, Unbehaun A, Dreysse S, et al. Transapical aortic valve implantation in 175 consecutive patients: excellent outcome in very high-risk patients. J Am Coll Cardiol 2010;56:813-20. 16. Beller CJ, Schmack B, Seppelt P, et al. The groin first approach for transcatheter aortic valve implantation: are we pushing the limits for transapical implantation? Clin Res Cardiol 2012. [Epub ahead of print]. 17. Kempfert J, Rastan A, Holzhey D, et al. Transapical aortic valve implantation: analysis of risk factors and learning

Cardiovascular Diagnosis and Therapy, Vol 2, No 4 December 2012 E11 experience in 299 patients. Circulation 2011;124:S124-9. 18. Kempfert J, Noettling A, John M, et al. Automatically segmented DynaCT: enhanced imaging during transcatheter aortic valve implantation. J Am Coll Cardiol 2011;58:e211. Cite this article as: Kempfert J, Walther T. Learning experience with transapical aortic valve implantation the initial series from Leipzig.. DOI: 10.3978/j.issn.2223-3652.2012.11.05