Babu Antharavally, Ryan Bomgarden, and John Rogers Thermo Fisher Scientific, Rockford, IL

Similar documents
DetergentOUT Tween. DetergentOUT GBS10. OrgoSol DetergentOUT

DetergentOUT GBS10 Spin Plates

DetergentOUT Detergent Removal Systems

Improve Protein Analysis with the New, Mass Spectrometry- Compatible ProteasMAX Surfactant

Development of a Human Cell-Free Expression System to Generate Stable-Isotope-Labeled Protein Standards for Quantitative Mass Spectrometry

Work-flow: protein sample preparation Precipitation methods Removal of interfering substances Specific examples:

Increased Efficiency of Biomolecule Identification by Optimization of Trypsin Digestion Buffers

The Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis

Trypsin Mass Spectrometry Grade

Multiplex Protein Quantitation using itraq Reagents in a Gel-Based Workflow

SMART Digest Kit Facilitating perfect digestion

Roti -Quant universal

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

Enhancing Sequence Coverage in Proteomics Studies by Using a Combination of Proteolytic Enzymes

In-Gel Tryptic Digestion Kit

Quick Technical Summaries Total Protein Assays

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Supplementary material: Materials and suppliers

Integrated Targeted Quantitation Method for Insulin and its Therapeutic Analogs

Quantitative Analysis of THC and Main Metabolites in Whole Blood Using Tandem Mass Spectrometry and Automated Online Sample Preparation

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

Comparison of Full Scan MS2 and MS3 Linear Ion Trap Approaches for Quantitation of Vitamin D

Glycosyltransferase Activity Kit

PosterREPRINT INTRODUCTION. 2-D PAGE of Mouse Liver Samples. 2-D PAGE of E.coli Samples. Digestion / Cleanup. EXPERIMENTAL 1-D PAGE of BSA Samples

GC-MS/MS Analysis of Benzodiazepines Using Analyte Protectants

Quantitative Determination of Proteins

Automating Mass Spectrometry-Based Quantitative Glycomics using Tandem Mass Tag (TMT) Reagents with SimGlycan

for the Identification of Phosphorylated Peptides

Agilent Protein In-Gel Tryptic Digestion Kit

Bioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS

TECHNICAL BULLETIN. R 2 GlcNAcβ1 4GlcNAcβ1 Asn

ab Glycated Protein Detection Kit

PosterREPRINT A NOVEL APPROACH TO MALDI-TOF-MS SAMPLE PREPARATION. Presented at ABRF 2002, Austin, Texas, USA, 9th - 12th March 2002.

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

Characterization of Disulfide Linkages in Proteins by 193 nm Ultraviolet Photodissociation (UVPD) Mass Spectrometry. Supporting Information

The distribution of log 2 ratio (H/L) for quantified peptides. cleavage sites in each bin of log 2 ratio of quantified. peptides

Phospholipid Assay Kit

Mercury Speciation Determinations in Asian Dietary Supplements

STORE AT 4 o C Version 3

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Lecture Estimation of protein

DELFIA Tb-N1 DTA Chelate & Terbium Standard

Trypsin Digestion Mix

Nature Methods: doi: /nmeth.3177

Manual. Precision Red Advanced Protein Assay Reagent. Cat. # ADV02. cytoskeleton.com. Cytoskeleton, Inc.

Sequence Identification And Spatial Distribution of Rat Brain Tryptic Peptides Using MALDI Mass Spectrometric Imaging

DELFIA Tb-DTPA ITC Chelate & Terbium Standard

Increased Identification Coverage and Throughput for Complex Lipidomes

For the rapid, sensitive and accurate measurement of Glycerol in cell cultures.

(III) MALDI instrumentation

For the accurate measurement of glycogen levels in various biological samples.

Enhanced LC-MS Sensitivity of Vitamin D Assay by Selection of Appropriate Mobile Phase

DELFIA Eu-DTPA ITC Chelate & Europium Standard

Protein MultiColor Stable, Low Range

Dayana Argoti, Kerry Hassell, Sarah J. Fair, and Joseph Herman Thermo Fisher Scientific, Franklin, MA, USA

Evaluation of an LC-MS/MS Research Method for the Analysis of 33 Benzodiazepines and their Metabolites

N-Glycan Sequencing Kit

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System

Glucose Detection Kit

Europium Labeling Kit

Improved Extraction and Analysis of Hexavalent Chromium from Soil and Water

Phospholipid Assay Kit

Shotgun Proteomics MS/MS. Protein Mixture. proteolysis. Peptide Mixture. Time. Abundance. Abundance. m/z. Abundance. m/z 2. Abundance.

Caution: For Laboratory Use. A product for research purposes only. Eu-W1024 ITC Chelate & Europium Standard. Product Number: AD0013

For the accurate measurement of glucose in cells and tissues, plasma, serum and other body fluids, growth media and food.

SUPPLEMENTARY MATERIAL

Microalbuminuric Diabetic patients N=18

PROTEIN QUANTIFICATION KIT - Wide Range

Universal sample preparation method for proteome analysis

LANCE Eu-W1024 ITC Chelate & Europium Standard AD0013 Development grade

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column

PTM Discovery Method for Automated Identification and Sequencing of Phosphopeptides Using the Q TRAP LC/MS/MS System

Measuring Phytosterols in Health Supplements by LC/MS. Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA

ProteaseMAX Surfactant, Trypsin Enhancer

Glucose Uptake Colorimetric Assay Kit

ab65336 Triglyceride Quantification Assay Kit (Colorimetric/ Fluorometric)

Testing robustness: Immunosuppressant drugs in blood with a TSQ Quantis MS for clinical research

Screening and Speciation of Raw and Processed Meat Products

Proteomics Grade. Protocol. Catalog # Agilent Technologies. Research Use Only. Not for use in Diagnostic Procedures. Version A, January 2010

Step 4. Step 4. Choose MW markers. Choose MW markers. Gel Electrophoresis of Proteins

Supplementary Materials for

Biological Detergents. Guide for solubilization of membrane proteins and selecting tools for detergent removal

Minute TM Plasma Membrane Protein Isolation and Cell Fractionation Kit User Manual (v5)

Note: During 30 minute incubation; proceed thru appropriate sections below (e.g. sections II, III and V).

Thermo Fisher Scientific, Sunnyvale, CA, USA; 2 Thermo Fisher Scientific, San Jose, CA, USA

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

Offline and online sample extraction for the quantification of benzodiazepines in human plasma or serum for clinical research

LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine

PIF: Precursor Ion Fingerprinting Searching for a Structurally Diagnostic Fragment Using Combined Targeted and Data Dependent MS n

Acetoacetate Assay Kit (Colorimetric)

N-Glycosidase F Deglycosylation Kit

L-Amino Acid Assay Kit

SUPPLEMENTARY INFORMATION

Quantification with Proteome Discoverer. Bernard Delanghe

Plant tissue extraction kit. For extraction of soluble protein and other biomolecules and metabolites from plant tissues.

Caution: For Laboratory Use. A product for research purposes only. Eu-W1284 Iodoacetamido Chelate & Europium Standard. Product Number: AD0014

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

Transcription:

A Versatile High-Recovery Method for Removing Detergents from Low-Concentration Protein or Peptide Samples for Mass Spectrometry Sample Preparation and Analysis Babu Antharavally, Ryan Bomgarden, and John Rogers Thermo Fisher Scientific, Rockford, IL

Overview Purpose: To efficiently remove detergents from low-concentration protein or peptide samples with high protein or peptide recovery for downstream applications. Methods: Colorimetric assays, A275 nm absorption and mass spectrometry (MS) analysis were used to measure the efficiency of detergent removal. Micro bicinchoninic acid (BCA) protein assays and sodium dodecyl sulfate - polyacrylamide gel electrophoresis (SDS-PAGE) analysis were used to determine the protein recovery. Results: The method successfully removed >95% of nonionic, ionic, and zwitterionic detergents from.5%-1% solutions with high recovery of proteins or peptides. Tandem mass spectrometric analysis of 2.5 1 μg of bovine serum albumin (BSA) enzymatic digests at 25 μg/ml, prepared in the presence of detergents and processed to remove detergent, revealed sequence coverage and Mascot TM scores as good as or better than control BSA samples processed without detergent. The method significantly removes detergents from very low concentration protein or peptide samples and eliminates the interference by detergents with the peptide mass spectral profile. The method can also be used in 96-well plate format to remove detergents with >95% efficiency at concentrations of.125%-1% with high protein/peptide recovery. The advantage of this method is the speed (less than 15 minutes), efficient detergent removal and high recovery of proteins and peptides. Introduction Mass spectrometry plays a central role in high-throughput proteomic analysis and provides a greater understanding of cellular regulation and global protein expression levels [1]. However, sample complexity, interfering substances, and the large dynamic range of protein and peptide concentrations are major hurdles in MS-based proteomic analysis. Sample preparation upstream of MS analysis is pivotal to success, and protein isolation methods commonly utilize reagents that are not compatible with mass spectrometry [2]. As a result, it is often necessary to modify procedures to avoid the use of interfering compounds. This is particularly true for protein isolation methods that utilize detergents. Detergents are commonly used in protein chemistry protocols and may be necessary for protein extraction, solubilization, and denaturation [3]. To enable downstream analysis by mass spectrometry, it is critical to remove unbound detergents from protein and peptide samples while maintaining good protein or peptide recovery, especially for low abundant proteins. Methods such as precipitation, solid phase extraction, desalting, or dialysis can be time consuming, inconsistent, and result in poor sample recovery. As an alternative to redeveloping these types of sample isolation procedures, we developed a detergent removal resin optimized for samples with very high detergent loads and with protein or peptide concentrations > µg/ml [4]. An alternative resin and protocol was later developed for samples with lower concentration ranges Thermo Scientific HiPPR (High Protein and Peptide Recovery) Detergent Removal Resin (Figure 1). The HiPPR Detergent Removal Resin is fast and effective at removing >95% of up to 1% detergents from protein or peptide samples with very low protein or peptide concentrations (1- µg/ml) with excellent sample recovery in less than 15 minutes. The spin column format is simple and efficient. Pre-filled 96-well plates enable fast and efficient high-throughput detergent removal of 192 samples in a single run. FIGURE 1. Protocol summary for Thermo Scientific HiPPR Detergent Removal Spin Columns (upper panel) and 96-well Spin Plates (lower panel) 2 A Versatile High-Recovery Method for Removing Detergents from Low-concentration Protein or Peptide Samples for Mass Spectrometry Sample Preparation and Analysis

Methods Detergent Removal Procedure: Protein (.375 μg 4 μg in 25 μl 2 μl) + detergent in buffer (.15M NaCl,.5% sodium azide, or.2m carbonate-bicarbonate buffer, ph 9.4) was processed with Thermo Scientific Pierce Detergent Removal Resin as shown in the protocol. Residual SDS was measured by colorimetric method using Stains-All dye [5]; Triton X- and NP-4 were measured by absorbance at 275 nm (protein absorbance was subtracted); CHAPS was measured by colorimetric method using concentrated sulfuric acid [6]. The Micro BCA Protein Assay was used for protein determination. LC-MS/MS Analysis: BSA (25 μg/ml) in 5mM ammonium bicarbonate buffer, ph 8. was reduced, alkylated and enzymatically digested for 3 hours at 37 ºC (enzyme-to-protein ratio, 1:5) in the presence of.5% detergents. To prepare the sample containing.5% SDS, the detergent was added to the sample following enzymatic digestion. Digested sample (.1 ml) containing the detergent was processed with.1 ml detergent removal resin as shown in the protocol. Control samples (labeled as unprocessed) were not processed with the resin. Samples were loaded (3 pmol) directly onto a C18 capillary column and subjected to LC-MS/MS analysis using a Thermo Scientific LTQ linear ion trap mass spectrometer. No trapping column was used. All data were analyzed using the Mascot search engine (Matrix Science). Results Part I: Removal of Detergents from Proteins BSA sample (25 2 μl) + detergent in.15m NaCl,.5% sodium azide was mixed with an equal volume of detergent removal resin (2x volume for CHAPS removal) and processed as shown in the protocol. Detergents were effectively removed with high protein recovery (Table 1). TABLE 1. Detergent removal efficiency and protein recovery Detergent Sample Volume (µl) Protein Quantity (µg) Detergent Removal (%) Protein Recovery (%) 25.375 >99 98 SDS (1%) 5.75 >99 97 1.5 >99 2 3. >99 25.375 >99 82 Triton X- (1%) 5.75 >99 86 1.5 >99 86 2 3. >99 93 25.375 95 9 NP-4 (.75%) 5.75 96 94 1.5 97 91 2 3. 97 97 25.375 95 64 CHAPS (1%) 5.75 97 7 1.5 98 78 2 3. 98 75 Thermo Scientific Poster Note PN63617_E 6/12S 3

A.1 ml protein sample (2 μg) + 1% SDS in buffer (.15M NaCl,.5% sodium azide, or.2m carbonate bicarbonate buffer, ph 9.4) was mixed with.1 ml detergent removal resin and processed as shown in the protocol. Detergent was effectively removed with high protein recovery (Table 2). TABLE 2. Detergent removal efficiency and protein recovery Protein SDS Removal (%) Protein Recovery (%) α-lactalbumin 99 98 Carbonic Anhydrase 99 81 Insulin 99 Protein (BSA) samples (15 µg/ml; 25, 5 and µl) in.15m NaCl,.5% sodium azide, + 1% SDS were mixed with detergent removal resin (25, 5 and µl) and processed as shown in the protocol. Samples (processed and unprocessed) were analyzed by SDS-PAGE and stained with Thermo Scientific GelCode Blue Stain Reagent. As shown in Figure 2, lanes 1-4 were processed samples with sample volumes 25, 5, and µl, respectively. Lanes 5 and 6 were unprocessed samples (1X & 2X). Lane 7 was the molecular weight marker. The data confirms the high recovery of proteins from low concentrated samples (BSA, 15 µg/ml) following the removal of detergent using Pierce Detergent Removal Resin. FIGURE 2. SDS-PAGE analysis of samples before and after detergent removal 1 2 3 4 5 6 7 A.1 ml BSA sample (1.5 µg) + detergent in.15m NaCl,.5% sodium azide was mixed with.1 ml HiPPR resin (.2 ml for CHAPS, octyl glucoside, and octyl thioglucoside) and processed as shown in the protocol. For the 96-well plate, samples (.1 ml) containing.25 mg/ml BSA and detergent were processed through the HiPPR Detergent Removal Spin Plate as described in the protocol (Table 3). TABLE 3. Maximum removable detergent concentrations Maximum Removable Detergent Concentration (%) Spin Column 96-Well Plate SDS 1.4 Sodium Deoxycholate 1.5 Triton X- 1.25 Triton X-114.5 ND NP-4.75.125 CHAPS* 1 1 Octyl Glucoside* 1 1 Octyl Thioglucoside* 1 1 *Maximum processable sample volume is 5 µl. ND: Not determined. 4 A Versatile High-Recovery Method for Removing Detergents from Low-concentration Protein or Peptide Samples for Mass Spectrometry Sample Preparation and Analysis

Part II: Removal of Detergents from Peptides BSA (.1 mg/ml) was digested in the presence and absence of detergents and the samples were processed for LC-MS/MS analysis as described in Methods. Detergents were effectively removed from the samples, eliminating the interference in MS analysis (Figure 3). FIGURE 3. LC-MS/MS analysis of enzymatically digested BSA. Base peak LC chromatograms before and after detergent removal. RT:. - 2. No Detergent, Unprocessed 5 +.5% Triton X-, Unprocessed 5 +.5% Triton X-, Processed 5 +.5% SDS, Unprocessed 5 Relative Abundance 5 5 +.5% NP-4, Unprocessed +.5% SDS, Processed +.5% NP-4, Processed 5 +.5% CHAPS, Unprocessed 5 +.5% CHAPS, Processed 5 2 4 6 8 1 12 14 16 18 2 Time (min) Thermo Scientific Poster Note PN63617_E 6/12S 5

BSA (25 and μg/ml) was digested in the presence and absence of SDS and the samples were processed for LC-MS/MS analysis as described in Methods. Effective detergent removal resulted in greater peptide identification and high Mascot scores (Figure 4). FIGURE 4. Number of unique peptides and sequence coverage per sample Conclusion The HiPPR Detergent Removal Resin: Efficiently removes detergents (>95%) from low concentration (15- μg/ml) protein and peptide samples Provides high recovery of proteins and peptides Removes detergents in sample volumes as small as 25 μl Provides simple, efficient, and fast removal with batch and 96-well plate formats that take less than 15 minutes for the entire process Eliminates detergent interference in downstream applications like ELISA, isoelectric focusing and mass spectrometry References 1. R. Aebersold, M. Mann. Mass spectrometry based proteomics. Nature, 422 (23) 198-27. 2. B. Canas, C. Pineiro, E. Calvo, D. Lopez-Ferrer, J. Gallardo. Trends in sample preparation for classical and second generation proteomics. J. Chrmotogr. A. 1153 (27) 235-258. 3. R.R. Loo, N. Dales, P.C. Andrews. The effect of detergents on proteins analyzed by electrospray ionization. Methods Mol.Biol. 61 (1996) 141-16. 4. B.S Antharavally, K.A. Mallia, M.M. Rosenblatt, A.M. Salunkhe, J.C. Rogers, P.J. Haney, N. Hagdoost. Efficient removal of detergents from proteins and peptides in a spin column format. Anal. Biochem. 416 (211) 39-44. 5. F. Rusconi, E. Valton, R. Nguyen, E. Dufourc. Quantitation of sodium dodecyl sulfate in microliter-volume biochemical samples by visible light spectroscopy. Anal. Biochem. 295 (21) 31-37. 6. A. Urbani, T. Worne. A colorimetric determination for glycosidic and bile salt-based detergents: applications in membrane protein research. Anal. Biochem. 336 (25) 117-124. Mascot is a trademark of Matrix Science Ltd. Triton is a registered trademark of The Dow Chemical Company. All other trademarks are the property of Thermo Fisher Scientific and its subsidiaries. This information is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. 6 A Versatile High-Recovery Method for Removing Detergents from Low-concentration Protein or Peptide Samples for Mass Spectrometry Sample Preparation and Analysis

www.thermoscientific.com/pierce 212 Thermo Fisher Scientific Inc. All rights reserved. These products are supplied for laboratory or manufacturing applications only. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Life Science Research Africa /Belgium/Europe/Middle East +32 53 85 71 84 France + 8 5 82 15 Germany +228 912565 Netherlands +76 5 31 88 Switzerland +8 56 31 4 UK +8 252 185 PN63617_E_6/12S Email: perbio.euromarketing@thermofisher.com www.thermoscientific.com/perbio For other regions, visit www.thermoscientific.com/piercedistributors USA +815-968-747 or +8-874-3723 Customer Assistance E-mail: Pierce.CS@thermofisher.com www.thermoscientific.com/pierce