number of artifacts from minute drill particles, even without

Similar documents
Cervical Spondylosis: Three-dimensional Gradient-Echo MR with Magnetization Transfer

Cervical Spine: Three-dimensional Fast Spin-Echo MR Imaging Improved Recovery of Longitudinal Magnetization with Driven Equilibrium Pulse 1

Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR: Comparison with Fast Spin-Echo MR in Diseases of the Brain

The Low Sensitivity of Fluid-Attenuated Inversion-Recovery MR in the Detection of Multiple Sclerosis of the Spinal Cord

Effects of Magnetic Susceptibility Artifacts and Motion in Evaluating the Cervical Neural Foramina on 30FT Gradient-Echo MR Imaging

High Field MR of the Spine

T HE detection of intracranial hemormhage is of critical importance in patient management due to the

Sensitivity and Specificity in Detection of Labral Tears with 3.0-T MRI of the Shoulder

The Behavior of Pantopaque on MR: In Vivo and In Vitro

Magnetic Resonance Angiography

High-Sensitivity Coil Array for Head and Neck Imaging: Technical Note

MR of Cervical Lymph Nodes: Comparison of Fast Spin-Echo and Conventional Spin-Echo T2W Scans

Diffusion-weighted MR Imaging Offers No Advantage over Routine Noncontrast MR Imaging in the Detection of Vertebral Metastases

MAJOR PAPER. Introduction. Young Han Lee 1, Seok Hahn 1, Eunju Kim 2, and Jin-Suck Suh 1*

Orthopedic Hardware Imaging Part II: MRI v. Metal

MR Advance Techniques. Vascular Imaging. Class II

Added value of MR myelography using 3D COSMIC sequence in the diagnosis of lumbar canal stenosis: comparison with routine MR imaging

RECENT ADVANCES IN CLINICAL MR OF ARTICULAR CARTILAGE

The Diagnosis of Herniated Intervertebral Disks with MR Imaging: A Comparison of Gradient

MR imaging the post operative spine - What to expect!

The Cervical Nerves and Foramina: Local-Coil MR Imaging

1 Normal Anatomy and Variants

SPINAL MAGNETIC RESONANCE IMAGING INTERPRETATION

Magnetic Resonance Imaging. Basics of MRI in practice. Generation of MR signal. Generation of MR signal. Spin echo imaging. Generation of MR signal

Correction of CSF Motion Artifact on MR Images of the Brain and Spine by Pulse Sequence Modification: Clinical Evaluation

Comparison of MERGE and Axial T2-Weighted Fast Spin-Echo Sequences for Detection of Multiple Sclerosis Lesions in the Cervical Spinal Cord

Detection of Intracranial Hemorrhage with Susceptibility- Weighted MR Sequences

Personal use only. MRI Metal Artifact Reduction: Shoulder Implants and Arthroplasty. Reto Sutter, MD

Signal intensity changes of the posterior elements of the lumbar spine in symptomatic adults

CARDIAC MRI. Cardiovascular Disease. Cardiovascular Disease. Cardiovascular Disease. Overview

Posterior longitudinal ligament status in cervical spine bilateral facet dislocations

MR Flow Imaging in Vascular Malformations Using Gradient Recalled Acquisition

Non Contrast MRA. Mayil Krishnam. Director, Cardiovascular and Thoracic Imaging University of California, Irvine

Contrast between Scar and Recurrent Herniated Disk on Contrast-Enhanced MR Images

STIR Sequence With Increased Receiver Bandwidth of the Inversion Pulse for Reduction of Metallic Artifacts

The mandibular condyle fracture is a common mandibular

Role of Diffusion WIs and T 2 * GRE Pulse Sequences in Dubious Vertebral Marrow Pathological Lesions

Diagnostic Value of 3D Fiesta Sequence in Imaging of Lumbar Radiculopathy

Clinical Applications

Study of the CNS. Bent O. Kjos' Richard L. Ehman Michael Brant-Zawadzki William M. Kelly David Norman Thomas H. Newton

CT is generally the preferred imaging technique in the assessment

Artificial Disc Replacement, Cervical

Modified Oblique Sagittal Magnetic Resonance Imaging of Rotator Cuff Tears: Comparison with Standard Oblique Sagittal Images

Estimation of CSF Flow Resistance in the Upper Cervical Spine

6/23/2009. Inversion Recovery (IR) Techniques and Applications. Variations of IR Technique. STIR, FLAIR, TI and TI Null. Applications of IR

MRI dynamics of brain and spinal cord in progressive multiple sclerosis

High-resolution T 2 -reversed magnetic resonance imaging on a high-magnetic field system Technical note

Comparison of T1-weighted fast spin-echo and T1-weighted fluid-attenuated inversion recovery images of the lumbar spine at 3.

Evaluation of Fat Suppression in Contrast-Enhanced MR of Neoplastic and Inflammatory Spine Disease

Magnetic Resonance Classification of Lumbar Intervertebral Disc Degeneration

Improvement of Fat Suppression and Artifact Reduction Using IDEAL Technique in Head and Neck MRI at 3T

Artificial Disc Replacement, Cervical

Revised Dec Spine MR Protocols

Table 1. Summary of PET and fmri Methods. What is imaged PET fmri BOLD (T2*) Regional brain activation. Blood flow ( 15 O) Arterial spin tagging (AST)

Fully Refocused Gradient Recalled Echo (FRGRE): Factors Affecting Flow and Motion Sensitivity in Cardiac MRI

Why Talk About Technique? MRI of the Knee:

Ibtisam Nasir Ahmed. MBChB. DMRD. Specialist Radiological Diagnosis. Al-sadr Teaching Hospital. Basrah-Iraq.

Cardiovascular MR Imaging at 3 T: Opportunities, Challenges, and Solutions 1

Speed, Comfort and Quality with NeuroDrive

How Much Tesla Is Too Much?

High Signal Intensity of the Infundibular Stalk on Fluid-Attenuated Inversion Recovery MR

Essentials of Clinical MR, 2 nd edition. 99. MRA Principles and Carotid MRA

3D titanium interbody fusion cages sharx. White Paper

Positional Magnetic Resonance Imaging. Description

Consortium of MS Centres Guidelines Revised Standardized MRI Protocol. for the Diagnosis and Follow-up of MS. David K.B.

Methods. Yahya Paksoy, Bülent Oğuz Genç, and Emine Genç. AJNR Am J Neuroradiol 24: , August 2003

1Pulse sequences for non CE MRA

MR of Intraparotid Masses

Calcified Intracranial Lesions: Detection with Gradient-Echo-Acquisition Rapid MR Imaging

Clinical Correlation of a New Practical MRI Method for Assessing Cervical Spinal Canal Compression

Acute traumatic spinal cord injury (SCI) is a devastating

multiple sclerosis by magnetic resonance imaging

Clinical Sciences Department. Notes on reserve in the library

Accelerated spondylotic changes adjacent to the fused segment following central cervical corpectomy: magnetic resonance imaging study evidence

Diagnostic value of 3D FIESTA sequence in imaging of lumbar radiculopathy

Extracranial Carotid Arteries: Evaluation with Black Blood MR Angiography

The Extracranial Facial Nerve: High Resolution Three-Dimensional Fourier Transform MR Imaging

Magnetic Resonance Imaging Findings in Degenerative Disc Disease of Cervical Spine in Symptomatic Patients

The Clinical Correlation of a New Practical MRI Method for Grading Cervical Neural Foraminal Stenosis Based on Oblique Sagittal Images

ACR MRI Accreditation: Medical Physicist Role in the Application Process

dgemric Effectively Predicts Cartilage Damage Associated with Femoroacetabular Impingement

Pictorial Essay. Jang Gyu Cha, MD, Hyun Sook Hong, MD, Jai Soung Park, MD, Sang Hyun Paik, MD, Hae Kyung Lee, MD INTRODUCTION

Magnetic susceptibility artefact on MRI mimicking lymphadenopathy: description of a nasopharyngeal carcinoma patient

Magnetic Resonance Imaging of the Spinal Cord and Canal: Potentials and

Tissue-engineered medical products Evaluation of anisotropic structure of articular cartilage using DT (Diffusion Tensor)-MR Imaging

Preparing for Medical Physics Components of the ABR Core Examination

The MR Appearance of CSF Pulsations in the Spinal Canal

The Pre-MRI Screening Questionnaire: Purpose and Rationale

The diffusion of water molecules in biologic tissues is altered

CSM is the most common cause of spinal cord dysfunction

PINPOINTING RADIATION THERAPY WITH THE PRECISION OF MR.

MR imaging techniques

MRI PEDIATRIC PROTOCOLS (Updated 6/19/2018)

MRI Information for Medtronic Spinal and Biologics Devices

Anatomic Evaluation of the Circle of Willis: MR Angiography versus Intraarterial Digital Subtraction Angiography

Dorsal Cervical Surgeries and Techniques

Traumatic injuries of the cervical spine are potentially catastrophic.

Note: This copy is for your personal, non-commercial use only. To order presentation-ready copies for distribution to your colleagues or clients, cont

MR Imaging of the Spine after Radiation Therapy:

Value of Lipid- and Water- Suppression MR Images in Distinguishing Between Blood and Lipid Within Ovarian Masses

Transcription:

Lisa M. Tartaglino, MD #{149}Adam E. Flanders, MD #{149}Simon Vinitski, PhD David P. Friedman, MD Metallic Artifacts on MR Images ofthe Postoperative Spine: Reduction with Fast Spin-Echo Techniques PURPOSE: To determine whether the relative insensitivity of T2- weighted fast spin-echo (FSE) techniques to magnetic susceptibility can be exploited to reduce metallic artifacts on images of the postoperative spine and, thus, improve the interpretation of the postoperative study. MATERIALS AND METHODS: Three neuroradiologists retrospectively evaluated sagittal T2-weighted conventional spin-echo and FSE images obtained in 15 patients with metallic artifacts from various sources including drill particles from anterior cervical diskectomy, posterior fixalion wires, fixation rods or plates, and an inferior vena cava filter. The amount of artifact present and whether these artifacts affected image interpretation were evaluated. RESULTS: Among the 45 paired evaluations, the artifact was judged to be less apparent with FSE sequences in 39. In eight of 45 evalualions (18%), the interpretation of the area of interest was possible only on the FSE images. CONCLUSION: FSE imaging, especially when performed with shorter echo spacing, increases the amount of T2-weighted information in the presence of metallic artifact because it decreases magnetic susceptibility effects. Index terms: Magnetic resonance (MR), artifact #{149}Magnetic resonance (MR), rapid imaging, 30.121416 Magnetic resonance (MR), comparative studies, 30.121411, 30.121416 Spine, MR, 30.121411, 30.121416 #{149}Spine, surgery, 30.453 Radiology 1994; 190:565-569 V ARIOUS metallic substances can preclude magnetic resonance (MR) imaging because of safety (1-3) and image degradation (4). This is a serious problem for spine imaging, because MR imaging may be the only modality capable of depicting certain lesions (eg, intramedullary disease). Spine stabilization surgery, by its very nature, utilizes extensive metallic hardware. Anterior cervical diskectomy with fusion can generate a considerable number of artifacts from minute drill particles, even without the installation of hardware (5,6). After safety considerations are met, the magnetic susceptibility effects of ferromagnetic and paramagnetic substances may obscure further imaging of the operative site when using standard spin-echo (SE) pulse sequences. Fast SE (FSE) imaging is a relatively new technique that may largely replace standard T2-weighted SE imaging. T2-weighted FSE pulse sequences can be performed in a fraction of the time of standard SE pulse sequences, often with improved signal-to-noise ratios and contrast (7). Preliminary studies have shown comparable lesion conspicuity in both cranial and spinal evaluation compared with conventional SE techniques (8-li). The small echo spacing inherent in the technique should lead to decreased magnetic susceptibility effects (8,12-15). The purpose of our study was to determine whether the relative insensitivity of FSE techniques to magnetic susceptibility could be exploited to reduce metallic artifacts on T2-weighted images. Moreover, we evaluated whether the artifact reduction was substantial enough to improve one s ability to evaluate a study. MATERIALS AND METHODS We retrospectively evaluated MR images obtained in i5 consecutive patients over a 4-month period; all images were obtained with a i.5-t imager (Signa; GE Medical Systems, Milwaukee, Wis) and were degraded by metallic artifacts. The patient population included patients with minute drill particles from anterior cervical diskectomy and fusion (n = 4), postenor cervical fusion wires (n = 4), posterior fusion rods and/or plates (thoracic and lumbar) (n = 4), anterior cervical fusion plates (n = 2), and a Bird s Nest inferior vena cava filter (Cook, Bloomington, md) (n = i). Conventional SE and FSE images were obtained in the sagittal plane at T2- weighted imaging in all patients. Both techniques were performed during the same examination. Parameters for SE imaging included a repetition time (TR) of i,800-2,000 msec, an echo time (TE) of 30, 80 msec, a 256 x 128 matrix, two signals averaged, 3- or 4-mm-thick sections with a I-mm gap, a 32-kHz bandwidth, and an examination time of 8-u minutes. FSE imaging was performed with a TR of 2,000-4,000 msec, an effective TE of i7, 80-i02 msec, an echo space of 17 msec, an echo train length of eight or i6, a 256 x 256 matrix, two or four signals averaged, 3- or 4-mm-thick sections with a I-mm gap, a 32-kHz bandwidth, and an examination time of 2-4 minutes. All images were evaluated by three neuroradiologists (L.M.T., A.E.F., D.P.F.), for a total of 45 paired evaluations. The neuroradiologists were blinded to all imaging parameters, and image pairs were evaluated in a random order. For each set of images, a subjective comparison was made as to the amount of artifact present. Each observer chose which image, if any, had less artifact. The following three-point scale was used by each observer to subjectively evaluate whether the artifact reduction improved the ability to interpret the study: i = not at all, 2 = somewhat, 3 = interpretable only on the study with decreased artifact. I From the Department of Radiology, Jefferson Medical College and Thomas Jefferson University Hospital, 10th and Sansom Sts, Rm 1072, Main Bldg. Philadelphia, PA 19107. From the 1992 RSNA scientific assembly. Received May 14, 1993; revision requested June 25; revision received September 14; accepted September 23. Address reprint requests to L.M.T. C RSNA, 1994 Abbreviations: FSE = fast spin echo, SE = spin echo, TE = echo time, TR = repetition time. 565

Figure 1. Posterior fusion wires. (a) Lateral plain radiograph of the cervical spine shows posterior fusion wires (arrows) extending from C-4 to C-6. (b) Sagittal T2-weighted SE MR image (TR msec/te msec = 2,000/80, two signals averaged, 256 x 128 matrix, 4-mm-thick sections, examination time = 8 minutes 56 seconds) of the cervical spine shows marked distortion of the posterior aspect of the canal and cord by metallic artifact (arrows). (c) Sagittal T2-weighted FSE MR image (2,000/102, two signals averaged, echo space = 17 msec, echo train length = eight, 256 x 256 matrix, 4-mm-thick sections, examination time = 2 minutes 12 seconds) at the same location shows marked improvement in the amount of distortion (arrows) compared with b. Observers then evaluated which sequence was best for resolution of vertebral bodies and intradural contents (including spinal cord when applicable). The same three-point scale was applied to subjectively evaluate whether the difference in resolution was due to decreased artifact and/or technical differences. This latter choice was included to minimize the effect of increased signal-to-noise ratio from the differences in matrix size and number of signals averaged between the FSE and SE sequences. Finally, observers were asked whether the sequences provided adequate T2- weighted sagittal information for evaluation of the vertebral bodies and intradural contents. Statistical analysis was performed with the sign test and the x2 test. RESULTS of the 45 paired evaluations, the artifact was judged to be less apparent with FSE sequences in 39 (87%) (Fig 1). In six of the paired evaluations, the artifacts were judged to be not significantly different, and in no case was the conventional SE technique judged to be better (P <.001, sign test). The overall reduction in artifact aided in the interpretation of the study in 34 of the 45 (75%) paired evaluations (Fig 2). This included eight of 45 paired evaluations (18%) in which interpretation was only possible with the FSE images and 26 (58%) in which the ability to interpret was somewhat improved. Those cases with posterior fusion rods showed the least improvement; although the artifact was reduced, the reduction was not substantial enough to aid in image interpretation. Resolution of intradural contents and vertebral bodies was almost always improved by the higher-spatialresolution imaging parameters of FSE imaging (89% and 83%, respectively). However, the reduction in the artifact seen on FSE images was judged to further improve the resolution (69% and 61%, respectively). FSE imaging was judged to provide adequate information about the vertebral bodies in 33 of the 45 paired evaluations (73%); SE imaging provided adequate information in 27 (60%). Though a trend was seen, this difference was not statistically significant (P =.69, x2 test). FSE imaging was judged to provide adequate information about the intradural contents in 27 of the 45 paired evaluations (60%); SE imaging provided adequate information in 16 (36%). This difference was statistically significant (P =.03, x2 test). DISCUSSION Magnetic susceptibility causes local field inhomogeneity and local field distortions leading to increased dephasing of the spins. This effect will increase with the length of time the spins have to dephase. Many factors will influence magnetic susceptibility effects, including field strength, chemical structure, density, spatial resolution, TE, echo spacing, and sampling bandwidth (16-19). The effect is greatest for ferromagnetic substances, less for paramagnetic substances, and least for diamagnetic substances (17). All patients in our study had some amount of ferromagnetic material related to surgery or a previously performed interventional procedure. The difference in TE and/or echo spacing between FSE and conventional SE imaging is the primary reason for the decreased artifact seen in our patients. The FSE pulse sequence (Fig 3a) is based on the Carr-Purcell-Meiboom- Gill echo train. This technique, originally called RARE (rapid acquisition 566 #{149} Radiology February 1994

d. Figure 2. Stainless steel Bird s Nest filter. (a) Oblique plain radiograph of the lumbar spine shows position of Bird s Nest filter (arrows). (b) Midline and (c) right parasagittal T2-weighted SE images (2,000/80, two signals averaged) of the lumbar spine show extensive metallic artifact (arrows), precluding evaluation of the lower disk spaces and canal. The patient was being evaluated for a right S-i radiculopathy. (d) Midline and (e) right parasagittal T2-weighted FSE images (2,967/96, four signals averaged, echo train length = 16) obtained at the same location show a right paracentral disk herniation (arrow in e) and osteophyte (arrow in d) at L-5-S-i. This abnormality correlated with the patient s right S-i radiculopathy. with relaxation enhancement), was first described by Hennig et al (20) and later elaborated on by others (13,i4,2i,22). After the 90#{176} pulse, multiple i80#{176} refocusing pulses are used per TR, each with a separate phaseencoding gradient and read-out in the presence of a frequency-encoded gradient. In the FSE pulse sequence, the TE is in actuality an effective TE made up of one to 16 echoes (echo train length). Therefore, multiple TEs are present, each corresponding to a different echo. T2 contrast is determined by those echoes occurring at the desired operator-chosen effective TE to fill the contrast-dependent areas of k space (low frequency), while the remainder of the echoes fill the detaildependent areas (high frequency) (9,13,22,23). The echo space is equal to the time between two echoes, as well as the time from the 90#{176} pulse to the first TE. Because the true echo space is considerably shorter than the effective TE, there is a much more limited period of time between each 180#{176} refocusing pulse for the spins to dephase before each echo is measured. In contrast, in conventional SE imaging (Fig 3b), within a given TR there is a 90#{176} pulse followed by a i80#{176} refocusing pulse. Because there is only one echo, there is no echo space. However, the time from the 90#{176} pulse to the TE is equivalent to the echo space. The period of time between the 180#{176} refocusing pulse and the echo at TE is considerably longer, allowing for increased dephasing of spins. This explains why the magnetic susceptibility effects are reduced with FSE techniques (Figs i, 2). In addition, with conventional SE sequences, only a single phase-encoding gradient is applied per TR, filling only a single line of k space, regardless of how many echoes are measured; this explains its longer imaging time. The importance of echo spacing on susceptibility effects has been shown previously (12) and is demonstrated in Figure 4, which shows two T2- weighted FSE images that were acquired with different echo spacing (i7 and ii msec, respectively). One might postulate that this difference in magnetic susceptibility effects due to echo spacing will be greatest between FSE and T2-weighted SE images because of the larger difference between the TE and the echo space. Correspond-

ES = I 80 ES ETL=4 180 90 90 PEG TE PEG2 PEG3 PEG4 TE 4 I EFFECTIVE TE =80. TE = 80 TR TA PEG = PHASE ENCODING GRADIENT TIME PEOD CONTRIBUTING TO MAGNETIC SUSCEPTIBILITY EFFECTS a. b. PEG = PHASE ENCODING GRADIENT TIME PERIOD CONTRIBUTING TO MAGNETIC SUSCEPTIBIUTY EFFECTS Figure 3. Comparison of conventional SE and FSE pulse sequences. (a) Diagram of FSE pulse sequence shows that the echo space (ES) is much shorter than the effective TE. There is a shorter period of time for the spins to dephase from each 180#{176} refocusing pulse to the echo measurements. ETL = echo train length. (b) Diagram of conventional SE pulse sequence shows the sample time between the 180#{176} refocusing pulse and the TE. ing proton density-weighted images (Fig 5b-5e) have a smaller difference between the TE and echo space and, therefore, should have a visibly smaller artifact difference. Although this reduction in magnetic susceptibility effects may be a disadvantage for detecting hemorrhage or calcium, it is of considerable benefit in patients who have ferromagnetic or paramagnetic substances distorting T2 information in the spine. In theory as well as practice, it is possible to minimize metallic artifacts. In several of our cases, diagnosis was possible only with FSE images (Fig 2). Similarly, Ti-weighted FSE sequences should not appreciably reduce the artifact when compared with Ti-weighted SE images because there would be little difference between the echo space and TE. Although anatomic structures may be better seen on Ti-weighted images, T2-weighted information is critical for evaluating intramedullary abnormalities and myelographic effect. The difference in magnetic susceptibility effects is further illustrated when comparing gradient-echo techniques that have no 180#{176} refocusing pulse and a moderate TE (24). More severe artifacts are seen with gradient-echo sequences than with either FSE or SE T2-weighted techniques. This is an important consideration because a gradient-echo sequence is often the only axial sequence performed in many routine examinations. It has become standard practice at our institution to omit axial and sagittal gradient-echo sequences when metallic artifact is present in the region of interest and replace them with FSE sequences. One criticism of this study is that it a. b. Figure 4. Effect of varying echo spacing on degree of artifact reduction. (a) Sagittal T2- weighted FSE image (2,000/85, two signals averaged, echo train length = eight, echo space = 17 msec) of the cervical spine in a patient with anterior fusion plate and screws from C-3 to C-5 shows moderate artifact over the vertebral bodies (arrows). (b) Sagittal T2-weighted FSE image (2,000/88, two signals averaged, echo train length = eight, echo space = 1 1 msec) obtamed at the same location as a shows decreased artifact (arrows). Note that noise increased as a result of the higher receive bandwidth that was required to obtain the shorter echo spacing. is not possible to blind an experienced reader to whether an FSE or a conventional SE image is being evaluated. Vertebral marrow will have high signal intensity on FSE images. Therefore, it is possible that a certain bias may still exist. We do not believe that this significantly altered the results. In conclusion, at T2-weighted MR imaging, FSE techniques offer improved evaluation of the spine in the presence of metallic artifacts when compared with conventional SE pulse sequences. These improvements are secondary to decreased magnetic susceptibility. Moreover, these benefits can be achieved in a shorter period of time. Although susceptibility artifacts are not eliminated, they may decrease sufficiently to provide diagnostically 568 #{149} Radiology February 1994

I : 4#{149} I \d14 L II4%,. t I I#{149} I II1 a. b. c. d. e. bl di S \ Figure 5. Variable appearance of metal shaving artifacts on gradient-echo, conventional SE, and FSE images. The patient had undergone antenor cervical diskectomy and fusion. (a) Sagittal T2*weighted gradient-echo image (450/14, 15#{176} flip angle) shows moderate distortion at the C5-C6 disk space, simulating an osteophyte (arrow). (b) Sagittal conventional T2-weighted SE image (1,800/80, two signals averaged) obtained at the same location as a shows a smaller artifact; however, it is still simulating an osteophyte (arrow). (c) Sagittal T2-weighted FSE image (2,200/85, two signals averaged, echo space = 17 msec, split echo train length = 16) obtained at the same location as a shows further reduction in the C5-C6 artifact (arrow). (d) Sagittal conventional proton-density-weighted SE image (1,800/30, two signals averaged) obtained at the same location as a shows the artifact (arrow) to be smaller than that seen in b. This is due to the shorter TE. (e) Sagittal proton-density-weighted FSE image (2,200/17 two signals averaged, echo space = 17 msec) shows the artifact (arrow) to be similar to that seen in c. This is because the echo spacing is equal in both. When compared with the conventional proton-density-weighted SE image (d), even though the artifact is smaller, the difference is less than when comparing T2-weighted images because of the corresponding smaller difference in echo spacing. useful T2-weighted information not otherwise available. Use of a shorter echo space will further decrease susceptibility-induced artifacts. Currently, the minimal echo space is limited by the width of the radio-frequency pulses, gradient amplitude, switching time, and duty cycle. As new software and instrumentation that allow larger echo train lengths with considerably shorter echo spacing become available, it is expected that these undesired artifacts will be further reduced. #{149} References 1. Kanal E, Shellock FG, Talagala L. Safety considerations in MR imaging. Radiology iq9o; 176:593-606. 2. Shellock FG, Schatz CJ. Metallic otologic implants: in vitro assessment of ferromagnetism at 1.5 T. AJNR 1991; 12:279-281. 3. Shellock FG, Curtis JS. MR imaging and biomedical implants, materials, and devices: an updated review. Radiology 1991; 180:541-550. 4. Laakman RW, Kaufman B, Han JS, et al. MR imaing in patients with metallic implants. Radiology 1985; 157:711-714. 5. Heindel W, Friedmann C, Thomas B, Firsching R, Ernestus RI. Artifacts in MR imaging after surgical intervention. J Comput Assist Tomogr 1986; 10:596-599. 6. Ross JS, Masaryk TJ, Modic MT. Postoperative cervical spine: MR assessment. J Comput Assist Tomogr 1987; 11:955-962. 7. Constable RT, Smith RC, Gore JC. Signal-tonoise and contrast in fast spin echo (FSE) and inversion recovery FSE imaging. J Comput Assist Tomogr 1992; 16:41-47. 8. Jones KM. Mulkern RV, Schwartz RB, Oshio K, Barnes PD, Jolesz FA. Fast spin-echo MR imaging of the brain and spine: current concepts. AJR r992; 158:1313-13211 9. Norbash AM, Glover GH, Enzmann DR. Intracerebral lesion contrast with spin-echo and fast spin-echo pulse sequences. Radiology 1992; 185:661-665. 10. Sze G, Merriam M, Oshio K, Jolesz FA. Fast spin-echo imaging in the evaluation of intradural disease of the spine. AJNR 1992; 13:1383-1392. 1 1. Ahn 55, Mantello MT. Jones KM, et al. Rapid MR imaging of the pediatric brain using fast spin-echo technique. AJNR 1992; 13:1169-1177. 12. Vinitski 5, Mitchell DG, Einstein MS, et al. Conventional and fast spin-echo MR imaging: minimizing echo time. JMRI 1993; 3:501-507. 13. Melki PS, Mulkern RV, Panych LP, Jolesz FA. Comparing the FAlSE method with conventional dual-echo sequences. JMRI 1991; 1:319-326. 14. Melki PS, Jolesz FA, Mulkern RV. Partial RF echo-planar imaging with the FAlSE method. II. Contrast equivalence with spin-echo sequences. Magn Reson Med 1992; 26:342-354. 15. Jones KM, Mulkern RV, Mantello MT. Brain hemorrhage: evaluation with fast spin-echo and conventional dual spin-echo images. Radiology 1992; 182:53-58. 16. Tsuruda JS, Remley K. Effects of magnetic susceptability artifacts and motion in evaluating the cervical neural foramina on 3DFT gradient-echo MR imaging. AJNR 1991; 12:237-241. 17. Bellon EM, Haacke EM, Coleman PE, Sacco DC, Steiger DA, Gangarosa RE. MR artifacts: a review. AIR 1986; 147:1271-1281. 18. Farahani K, Sinha U, Sinha 5, et al. Effect of field strength on susceptibility artifacts in magnetic resonance imaging. Comput Med Imaging Graph 1990; 14:409-413. 19. Vinitski 5, Griffey R, Fuka M, Matwiyoff N, Prost R. Effect of the sampling rate on magnetic resonance imaging. Magn Reson Med 1987; 5:278-285. 20. Hennig J, Naurth A, Friedburg H. RARE imaging: a fast imaging method for clinical MR. Magn Reson Med 1986; 3:823-833. 21. Hennig J, Friedburg H. Clinical applications and methodological developments of the RARE technique. Magn Reson Imaging 1988; 6:391-395. 22. Mulkern RV, Wong STS, Winalski C, Jolesz FA. Contrast manipulation and artifact assessment of 2D and 3D RARE sequences. Magn Reson Imaging 1990; 8:557-566. 23. Constable RT, Anderson AW, Zhong J, Gore JC. Factors influencing contrast in fast spinecho MR imaging. JMRI 1992; 10:497-511. 24. Czervionke LF, Daniels DL, Wehrli FW, et al. Magnetic susceptibility artifacts in gradientrecalled echo MR imaging. AJNR 1988; 9:1149-1155. Inn MmIir9 RI #{149}