JAMES R. KNIGHT

Similar documents
Non-Invasive Method of Blood Pressure Measurement Validated in a Mathematical Model

CARDIOVASCULAR MONITORING. Prof. Yasser Mostafa Kadah

HUMAN ANATOMY AND PHYSIOLOGY

External Oscillatory Blood Pressure - EOBPTM

#6 - Cardiovascular III Heart Sounds, Pulse Rate, Hemoglobin Saturation, and Blood Pressure

MR Advance Techniques. Cardiac Imaging. Class IV

Oximeters. Hsiao-Lung Chan, Ph.D. Dept Electrical Engineering Chang Gung University, Taiwan

How Does Pulse Oximetry Work? SpO2 Sensors Absorption at the Sensor Site Oxyhemoglobin Dissociation Curve

12.2 Monitoring the Human Circulatory System

Diagnostic Ultrasound. Sutiporn Khampunnip, M.D.

A GUIDE TO OUR NIBP TECHNOLOGY

ADVANCED PATIENT MONITORING DURING ANAESTHESIA: PART ONE

Biomedical Instrumentation E. Blood Pressure

Measuring Heart Rate and Blood Oxygen Levels for Portable and Wearable Devices

Oximeters. Hsiao-Lung Chan, Ph.D. Dept Electrical Engineering Chang Gung University, Taiwan

The Heart 1 of 34 Boardworks Ltd 2012

Clinical Research Coordinator Skills Program

SYNCHRONIZED MEASUREMENTS OF MAXIMUM BLOOD FLOW VELOCITIES IN CAROTID, BRACHIAL AND FEMORAL ARTERIES, AND ECG IN HUMAN POSTURE CHANGES

Physiological Measurements Training for Care/Nursing & LD Small Group Home Staff

Chapter 12 - Vital_Signs_and_Monitoring_Devices

Sound in medicine. CH.12. Dr.Rajaa أ.م.د. رجاء سهيل جنم جامعة تكريت كلية طب االسنان. General Properties of Sound

Vascular Testing. and. You

PHONOCARDIOGRAPHY (PCG)

Your surgeon will order pre-operative testing before you have surgery.

Design a system of measurement of heart rate, oxygen saturation in blood and body temperature with non-invasive method

Lectures on Medical Biophysics Department of Biophysics, Medical Faculty, Masaryk University in Brno. Biophysics of cardiovascular system

Objectives of the Heart

Oxygen Saturation Monitors & Pulse Oximetry. D. J. McMahon rev cewood

Admission of patient CVICU and hemodynamic monitoring

Journal of Faculty of Engineering & Technology DESIGN AND IMPLEMENTATION OF A WEARABLE HEALTH DEVICE

Monitoring Equipment. Blood Pressure Monitor Upper Arm Type: Image (Image not to scale)

Heart Rate, Blood Pressure, and Exercise. Evaluation copy

Experiment B-18 Heart Rate and Coughing

Optimising your Doppler settings for an accurate PI. Alison McGuinness Mid Yorks Hospitals

1. Which of the following blood vessels has a thin elastic layer? A. Aorta. B. Pulmonary artery. C. Posterior vena cava. D. Mesenteric capillary.

Science in Sport. 204a ECG demonstration (Graph) Read. The Electrocardiogram. ECG Any 12 bit EASYSENSE. Sensors: Loggers: Logging time: 10 seconds

Cardiovascular Effects of Exercise. Background Cardiac function

Blood Pressure Estimation Using Photoplethysmography (PPG)

Anaesthesia for ECT. Session 2. Dr Richard Cree Consultant in Anaesthesia & ICU. Roseberry Park Hospital and The James Cook Hospital, Middlesbrough

Chapter 3 Biological measurement 3.1 Nerve conduction

Taking and recording blood pressure and pulse. City Gate Training Centre all rights reserved

CARESCAPE Patient Data Module

Research Journal of Pharmaceutical, Biological and Chemical Sciences

THE CARDIOVASCULAR SYSTEM : (circulatory system) Lab-4

Baseline Vital Signs and SAMPLE History. Chapter 5

Ankle-Brachial Blood Pressure

Medical Electronics Dr. Neil Townsend Michaelmas Term 2001 ( The story so far.

LABORATORY INVESTIGATION

Rigel UNI-SiM Lite. The most cost-effective patient simulator on the market. Key Features n Compact and cost-effective

Lab #3: Electrocardiogram (ECG / EKG)

How To Measure Vital Signs

Cardiac Cycle. Each heartbeat is called a cardiac cycle. First the two atria contract at the same time.

Rigel UNI-SiM. The world s smallest integrated NiBP, SpO2 and patient simulator. Key Features n Compact and cost-effective

Optical Sensor System for Hemoglobin Measurement

Biomedical Instrumentation D. The Photoplethysmogram

Blood Pressure Laboratory

5.2. MEASUREMENT OF BLOOD PRESSURE

Measuring body temperature, blood pressure, pulse, respiratory rate and oxygen saturation

Transducers (Medical Applications)

A Simulation for Estimation of the Blood Pressure using Arterial Pressure-volume Model

Physical Principles of Ultrasound

1 Non-invasive measurement of arterial pressure

The Circulatory System. Lesson Overview. Lesson Overview The Circulatory System

EGR1200 Freshman Mini Project Biomedical Signal Analysis

Chapter 9, Part 2. Cardiocirculatory Adjustments to Exercise

Introduction to Biomedical Imaging

Chapter 15: Measuring Height, Weight, and Vital Signs. Copyright 2012 Wolters Kluwer Health Lippincott Williams & Wilkins

Shock, Monitoring Invasive Vs. Non Invasive

MR Advance Techniques. Cardiac Imaging. Class III

Control of Heart Rate

Abdominal Ultrasound

EXPERIMENTS WITH BLOOD PRESSURE MONITORING USING ECG AND PPG

Lab 4: Introduction to Physiological Measurements - Cardiovascular

CIE Biology GCSE. 9: Transport in animals. Notes.

Biology 212: Anatomy and Physiology II. Lab #5: Physiology of the Cardiovascular System For Labs Associated With Dr. Thompson s Lectures

Cardiovascular Physiology

2The Concept of Periodic Functions

This leaflet is intended for patients with permanent pacemakers and their parents.

BP-600 Noninvasive Blood Pressure Sensor

Pancreas: digestive enzymes Liver: bile-helps to digest fat, stored in gallblader; breaks down toxins, makes some parts of blood

Circulatory System. Functions and Components of the Circulatory System. Chapter 13 Outline. Chapter 13

Cardiac Output Monitoring - 6

Introduction. Cardiac Imaging Modalities MRI. Overview. MRI (Continued) MRI (Continued) Arnaud Bistoquet 12/19/03

ECE ECE PRINCIPLES OF BIOMEDICAL SYSTEMS & DEVICES LAB 1 - ELECTROCARDIOGRAM

AN INTRODUCTION TO DOPPLER. Sarah Gardner, Clinical lead, Tissue viability service. Oxford Health NHS Foundation Trust.

AGENDA for 04/04/14 AGENDA: HOMEWORK: Due Tues, Online Quiz: OBJECTIVES:

Circulatory System Review

science-u.org What affects blood Blood Pressure Directions You Will Need BEST FOR GRADES 5-8 ESTIMATED TIME Minutes

Keun-Ho Kim and Sang-Suk Lee* Department of Oriental Biomedical Engineering, Sangji University, Wonju , Korea

The Electrocardiogram

ALCO Regulations. Protocol pg. 47

Biology Unit 3 The Human Heart P

Chapter 12. Capillaries. Circulation. The circulatory system connects with all body tissues

Outline. Electrical Activity of the Human Heart. What is the Heart? The Heart as a Pump. Anatomy of the Heart. The Hard Work

Human Anatomy and Physiology II Laboratory Cardiovascular Physiology

Lesson 07: Ultrasound Transducers. This lesson contains 73 slides plus 16 multiple-choice questions.

Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing

MUGA Scan. A Patient s Guide. Copyrighted Material. HeartWise Patient Education

Choosing Mindray SpO2

An abdominal ultrasound produces a picture of the organs and other structures in the upper abdomen.

Transcription:

JAMES R. KNIGHT knightjr@ah.org James is currently the supervisor of clinical engineering at Sonora Regional Medical Center. He is the chairman of the CMIA Training & Education Committee. He also develops biomedical technology training curriculums for both colleges and employers. He was certified by the I.C.C. as a CBET in August 21, 1997. He has worked on biomedical instrumentation since 1985. He is factory trained on nuclear cameras, general radiology & fluoroscopy and cardiac assist equipment used in heart transplants.

Fetal Monitoring Monitors both mother and soon to be born child Maternal monitoring: 1. NIBP trending 2. SpO2 trending 3. Intra-uterine pressure (external or internal) relative 4. Electrocardiogram (ECG) actual Fetal monitoring: 1. Ultrasound heart rate actual 2. Scalp electrode heart rate actual

Heart beat create pressure waves The human heart serves as a pump pushing blood through the arteries with each heart beat which produces pressure pulses.. Pressure pulses then move away from the heart through the arterial system of the body in the form of a pressure wave,, which changes as it moves further away from the heart. These pressure waves create arterial pulsations that can be detected in multiple locations on the human body. Arterial blood pressure is measurement of these pulsations caused by the pressure waves generated by the heart pushing blood through the arteries.

Non-Invasive Blood Pressure Inflates cuff placed over brachial artery to preset pressure, usually ually 160 to 180 mm of Hg Detects systole: first pulses (SP), diastole: last pulse (DP) and calculates the mean: Approximately Actually DP + 1/3 ( SP - DP ) ( CO x SVR ) + CVP NIBP is not actual blood pressure, used only for trending Two methods are used : Ausculatory uses a microphone at brachial artery Oscillometric detects SP and DP by oscillations in pressure

SpO2 trending Measures the number of oxyhemoglobin molecules carrying oxygen at peripheral site, usually the middle finger. Approximates the invasive, painful and slow method of arterial blood sampling. Usually 96 to 99% reading, also detects heart rate. Sensor has two emitting led s s (red & IR) and one photodiode detector.

How to detect oxygen: Hemoglobin with oxygen attached is red. Hemoglobin without oxygen is blue. Arterial blood has higher pulse pressure than venous blood. By measuring the quantity of red in the arterial blood we can estimate how much of the arterial hemoglobin is oxygenated (SpO2 : percent O2 saturation) Pulsing two frequencies of light ( red and infrared ) from the sensor and measuring how much light is reflected back ( not absorbed by the body) will yield the R value.

R value Red SP / Red DP IR SP / IR DP Yields R All values are actually integrals, areas under the curve, x being millivolts and y being milliseconds SP is an ac signal since it is pulsing DP is dc value since it is resting

R curve % O2 Saturation 100 90 80 70 60 50 40 30 20 10 0 0.5 1 1.5 2 2.5 R Value

Brands of SpO2 monitors Nellcor Massimo Nonin Philips Nellcor uses four phase sequence: 1. 184.5 usec IR on 2. 184.5 usec both off 3. 184.5 usec red on 4. 184.5 usec both off

Uterine monitoring Relative pressure within the uterus is measured using a tocotransducer attached with a belt to the mother s s abdomen in the area of the uterine fundus. The readings are plotted on strip chart recorder on a relative scale from 0 to 100. The resulting graph shows contractions. As the contractions increase in size and lessen in time apart, the clinician is made aware of the pending delivery.

Uterine monitoring can be accomplished two ways Externally through a tocotransducer that measures relative pressure changes of the uterine wall Internally via a transcervical catheter.

ECG monitoring Accomplished with 3 leads, Left & right arms and either left or right leg electrodes. Ag / AgCl electrodes sense a voltage potential difference that is created by K and Na ions traveling in & out of cardiac cell walls. There is no current flow, it is actually action potential.

Ultrasound Monitoring Used to detect both maternal and fetal heart rate (actual). Uses pulsed Doppler probe to hear an echo of the heart pumping Usually a gel is placed between probe and mother to increase gain, reduce noise. Most common failure is the probe on a fetal monitor.

Doppler Probe measures heart rate Operating Frequency 1-15MHZ1 15MHZ Material Velocity (Meter/Sec) Air 330 Water 1480 Tissue 1540 Piezoelectricity (Pressure Electricity) Piezoelectric crystal-converts converts one form of energy to another Does not transmit through air or bone Conductive gel between probe and patient for better conduction Corometrics uses 1.151 MHz pulsed carrier signal with a 4 khz pulsed repetition frequency. The total wave form lasts 250 microseconds with 4 parts: 90usec tx Doppler pulse, 40 usec wait,, 90 usec receive reflected signals, 30 usec idle state.