The innovative aspects are that ORA G3 is currently the only device capable of measuring corneal hysteresis.

Similar documents
Key uncertainties around the evidence or technology are that the test has only been validated in biochemical studies.

The innovative aspects are that the test automatically generates a report on ALK status that any clinician can interpret.

pat hways Medtech innovation briefing Published: 29 November 2016 nice.org.uk/guidance/mib87

The innovative aspect is that it detects bladder cancer based on the novel biomarker, minichromosome maintenance complex component 5 (MCM5).

GDm-Health is free to download and use. Its use may result in efficiency savings from reducing face-to-face clinic appointments.

pat hways Medtech innovation briefing Published: 24 August 2016 nice.org.uk/guidance/mib76

pat hways Medtech innovation briefing Published: 24 August 2016 nice.org.uk/guidance/mib77

pat hways Medtech innovation briefing Published: 24 August 2018 nice.org.uk/guidance/mib157

The technology described in this briefing is Promonitor. It is used to monitor response to biologic therapies.

Make a more confident glaucoma risk assessment with Corneal Hysteresis, a superior predictor of glaucoma progression.

pat hways Medtech innovation briefing Published: 14 December 2018 nice.org.uk/guidance/mib166

The technology described in this briefing is Permacol, a collagen paste that is injected into anal fistulae.

The technology described in this briefing is minimally invasive percutaneous nephrolitholapaxy medium (MIP-M). It is used to remove kidney stones.

pat hways Medtech innovation briefing Published: 16 May 2018 nice.org.uk/guidance/mib147

LOCSU Community Services. Glaucoma Repeat Readings & OHT Monitoring Community Service Pathway. Issued by Local Optical Committee Support Unit May 2009

pat hways Medtech innovation briefing Published: 20 September 2017 nice.org.uk/guidance/mib120

Clinical Guidance and Monitoring for Change. Cecilia Fenerty MD FRCOphth Manchester Royal Eye Hospital

LOCSU Community Services. Glaucoma Repeat Readings & OHT Monitoring Community Service Pathway. Issued by Local Optical Committee Support Unit May 2009

The cost of the Axonics sacral neuromodulation system is 475 for the trial phase, 9,210 for a

Medical Management of Glaucoma

pat hways Medtech innovation briefing Published: 1 October 2018 nice.org.uk/guidance/mib161

Glaucoma: diagnosis and management (large print version)

pat hways Medtech innovation briefing Published: 15 March 2016 nice.org.uk/guidance/mib57

The intended place in therapy would be to replace IHC testing in people with early-stage breast cancer.

NICE guideline Published: 1 November 2017 nice.org.uk/guidance/ng81

Comparative study of new imaging technologies for the diagnosis of glaucoma: Protocol Approved by the Ethics Committee

PRESCRIBING IN GLAUCOMA: GUIDELINES FOR NZ OPTOMETRISTS

The technology described in this briefing is the Zio Service. It is a remote cardiac monitoring system used for detecting cardiac arrhythmias.

GLAUCOMA REPEAT READINGS PATHWAY

The technology described in this briefing is Arctic Sun It is used for therapeutic body temperature management.

Commissioning Guide: Glaucoma (Long Version)

Glaucoma. Glaucoma. Optic Disc Cupping

Intro to Glaucoma/2006

pat hways Medtech innovation briefing Published: 4 December 2017 nice.org.uk/guidance/mib132

Evaluation of the Effect of Diabetes Mellitus on Corneal Biomechanics

pat hways Medtech innovation briefing Published: 19 November 2014 nice.org.uk/guidance/mib14

A comparison of HRT II and GDx imaging for glaucoma detection in a primary care eye clinic setting

The Ocular Response Analyzer (ORA; Reichert Ophthalmic

Clinical Commissioning Policy Proposition: Robotic assisted lung resection for primary lung cancer

Glaucoma. National Guideline Centre. Glaucoma: diagnosis and management. NICE guideline 81. October Final. Methods, evidence and recommendations

England. Suspect OHT/Glaucoma. Repeat Readings Service Common Pathway

1/31/2018. Course Objectives. Diagnostic Testing. Optic Nerve Damage ANATOMY AND PHYSIOLOGY OF A GLAUCOMA WORK-UP/TONOMETRY TECHNICIAN: -SDP

The Common Clinical Competency Framework for Non-medical Ophthalmic Healthcare Professionals in Secondary Care

Low back pain and sciatica in over 16s NICE quality standard

Glaucoma Care Pathway

Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma

Glaucoma is the most frequent

Glaucoma research at Moorfields

Clinical Commissioning Policy Statement: Co-careldopa Intestinal Gel (Duodopa) December Reference : NHSCB/D4/c/3

CLINICAL SCIENCES. Comparison of Ocular Response Analyzer Parameters in Chinese Subjects With Primary Angle-Closure and Primary Open-Angle Glaucoma

Specialised Services Policy Position PP104

Equality Act 2010 Fact Sheet

Delivering first class mental health care services in south west London Committed to care, creating communities

Clinical Commissioning Policy Proposition:

Comparison of Intraocular Pressure Measurements by the Ocular Response Analyzer and Goldmann Applanation Tonometer after Penetrating Keratoplasty

You said we did. Our Healthier South East London. Dedicated engagement events

Title Use of Pre-Operative Tests for Elective Surgery Guideline. Department. Anaesthetics. Comment / Changes / Approval

ifuse implant system for treating chronic sacroiliac joint pain

Central Corneal Thickness-An important variable for prognostication in Primary Open Angle glaucoma; A Kolkata based study in Eastern India

LARGE DISCS WITH LARGE CUPS A DIAGNOSTIC CHALLENGE IN AFRICAN PATIENTS. Darshana Soma

PALIPERIDONE LONG ACTING INJECTION PRESCRIBING GUIDELINE. Chief Pharmacist. Chief Pharmacist

CORNEAL HYSTERESIS AND INTRAOCULAR PRESSURE MEASUREMENT

DRAFT FOR CONSULTATION. Clinical Commissioning Policy Proposition: Robotic assisted trans-oral surgery for throat and voice box cancers

NO SMOKING POLICY. Organisational

Corneal hysteresis in patients with glaucoma-like optic discs, ocular hypertension and glaucoma

CORNEAL HYSTERESIS AND INTRAOCULAR PRESSURE MEASUREMENT

December 2016, Volume: 8, Issue: 12, Pages: , DOI:

Clinical Commissioning Policy Statement: Flow Diverting Devices for Intracranial Aneurysms. April Reference : NHSCB/D03/PS/a

Relationship between corneal biomechanical properties and structural biomarkers in patients with normal-tension glaucoma: a retrospective study

Glaucoma: Diagnostic Modalities

PRACTICAL APPROACH TO MEDICAL MANAGEMENT OF GLAUCOMA

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE SCOPE. Glaucoma: diagnosis and management of chronic open angle glaucoma and ocular hypertension

Noel de Jesus Atienza, MD, MSc and Joseph Anthony Tumbocon, MD

Costing report. Glaucoma: diagnosis and management of chronic open angle glaucoma and ocular hypertension. Implementing NICE guidance.

Report for EYEGENETIX. Prepared on. May 24, By: David Davis, CPC, CPC-H, CCC (Ret.)

Dr. Harvey Richman, OD, FAAO, FCOVD Diplomate American Board of Optometry Executive Committee AOA Third Party Center Founder Ask the AOA Coding

2. Dr Ahmad Nasser Affiliations: Foundation Year 2 doctor, NHS West Lothian Foundation Programme, St. Johns Hospital, Livingston, Scotland, UK

GLAUCOMA. phone (64) fax (64) web

Retinal Nerve Fiber Analysis: the Role It Plays in Assessing Glaucoma Grace Martin, CPOT

NICE guidelines. Flu vaccination: increasing uptake in clinical risk groups and health and social care workers

Factors Associated With Visual Field Progression in Cirrus Optical Coherence Tomography-guided Progression Analysis: A Topographic Approach

Clinical Commissioning Policy Proposition: Selexipag in the treatment of Pulmonary Arterial Hypertension

Hoarding Policy. Version 1.1 Date of Last Update: 18/12/15

pat hways Medtech innovation briefing Published: 16 February 2018 nice.org.uk/guidance/mib141

ADVISORY OPINION OF THE CODE OF ETHICS

THE CHRONIC GLAUCOMAS

True IOP No Doubt Facts and Figures Figures. Ziemer Ophthalmic Systems AG a Ziemer Group Company Allmendstrasse 11 CH-2562 Port, Switzerland

The Role of the RNFL in the Diagnosis of Glaucoma

The intended place in therapy would be as an alternative to current laboratory-based creatinine testing in people needing contrast-enhanced imaging.

Enhanced Scheme Evalua<on Project (ESEP)

LOCSU/WOPEC Courses to support the development of local enhanced eye care services. Excellence in Education for Eye Care Professionals

Multidisciplinary Glaucoma Service Design. Paul GD Spry PhD MCOptom DipGlau DipTp(IP) Head of Optometry, Bristol Eye Hospital

Enhanced Scheme Evaluation Project (ESEP) Robert Harper On behalf of the ESEP team

Medical technologies guidance Published: 23 January 2019 nice.org.uk/guidance/mtg41

SALBUTAMOL INHALER PATIENT GROUP DIRECTION CHILD HEALTH 1. Aim/Purpose of this Guideline

Corneal Hysteresis and Visual Field Asymmetry in Open Angle Glaucoma SUBJECTS AND METHODS

Research Article Long-Term Clinical Course of Normal-Tension Glaucoma: 20 Years of Experience

Goals. Glaucoma PARA PEARL TO DO. Vision Loss with Glaucoma

Glaucoma is the leading cause of irreversible blindness in

Transcription:

pat hways ORA G3 to measure corneal hysteresis Medtech innovation briefing Published: 18 June 2018 nice.org.uk/guidance/mib150 Summary The technology described in this briefing is Ocular Response Analyzer (ORA) G3. It can be used to measure corneal hysteresis, a possible risk factor for glaucoma. The innovative aspects are that ORA G3 is currently the only device capable of measuring corneal hysteresis. The intended place in therapy would be when diagnosing and managing suspected glaucoma or monitoring established glaucoma. ORA G3 would be used in addition to standard care, specifically ophthalmic tests including Goldmann applanation tonometry. The main points from the evidence summarised in this briefing are from 5 observational studies, 4 in the US and 1 in Korea, including a total of 635 adults recruited from glaucoma clinics. Results show that lower levels of corneal hysteresis are associated with the development and progression of glaucoma. uncertainties around the evidence or technology are whether the published studies are applicable to the NHS, and if corneal hysteresis is indeed a reliable risk factor for glaucoma. The cost of ORA G3 is,995 per unit (excluding VAT), plus additional costs for maintenance and consumables. The resource impact would be greater than standard care, but using ORA G3 may provide more long-term savings if measuring corneal hysteresis allows for earlier diagnosis and treatment of glaucoma. Page 1 of

The technology Ocular Response Analyzer (ORA) G3 (Reichert Technology) is a dynamic bidirectional applanation device used to measure corneal hysteresis. ORA G3 is table-mounted and controlled by a healthcare professional through an in-built operator display. The patient positions their head in a headrest, which is adjusted to allow for measurements of the left or right eye. The device blows a short puff of air to slightly flatten the cornea, which then returns to its original shape. During this the device takes 2 measurements: the force needed to flatten the cornea and the force needed for it to reshape. The difference between the 2 measurements is defined as the level of corneal hysteresis (measured in mmhg). ORA G3 can also be used to measure intraocular pressure, but this briefing focuses on its use to measure corneal hysteresis. Innovations ORA G3 is currently the only device that can measure corneal hysteresis. Unlike other tests, it does not need contact with the eye, specialist training or the use of eye drops. Current NHS pathway The NICE guideline on glaucoma recommends several tests to diagnose and manage glaucoma (see table 2). The guideline does not include recommendations on measuring corneal hysteresis specifically, but some evidence suggests that lower levels of corneal hysteresis may be linked to the development or progression of glaucoma. Population, setting and intended user ORA G3 is intended as an additional option for diagnosing or managing suspected glaucoma, or for monitoring established glaucoma. It is possible to have open angle glaucoma without raised intraocular pressure, so measuring corneal hysteresis could be more useful in this patient group. Assessments using ORA G3 would usually be done in secondary care by a healthcare professional or trained technician. The company has stated that minimal training is needed to use the device. Page 2 of

Costs Technology costs The estimated cost per test with ORA G3 is 0.20. This has been calculated by dividing the total cost of the device, service and maintenance fees, and consumables by the number of patients that would have the test in 10 years (the predicted lifespan of the device; this equates to 75,000 patients). The estimated cost per test does not include the time of a healthcare professional. Table 1 Costs for ORA G3 Description Cost Additional information ORA G3 device,995.00 The expected lifespan of the device is 10 years. Biannual service and maintenance 395.00 per service Over 10 years, 4 services would be needed. Alcohol wipes 0.02 each The company estimates that around 30 patients would All costs were provided by the company. have an ORA G3 test each day. Costs of standard care Table 2 shows estimated costs for each of the tests recommended by NICE as an option for diagnosing and managing glaucoma. The estimates do not include the cost of consumables or the time of a healthcare professional. Excluding these, the average cost per test is 0.09. Table 2 Costs of tests to diagnose and manage glaucoma Test Cost per patient Measuring intraocular pressure using Goldmann applanation tonometry 0.09 Optic nerve assessment and fundus examination 0.04 Gonioscopy 0.14 Measuring central corneal thickness 0.09 Page 3 of

Visual field assessment using standard automated perimetry 0.09 Resource consequences The resource impact of ORA G3 would be greater than standard care at first because the test is more costly. However, the company claims that after the first year, ORA G3 becomes cost saving for the rest of the device's lifespan (that is, 10 years). If corneal hysteresis were proven to be a risk factor for glaucoma, and ORA G3 enabled earlier diagnosis, there may be associated cost savings from starting treatment sooner. If ORA G3 were adopted by the NHS, ophthalmology care providers would need to accommodate the device in examination rooms or clinic areas. ORA G3 is currently being used in 8 NHS hospitals. Regulatory information ORA G3 was CE marked as a class IIa device in 2005. Equality considerations NICE is committed to promoting equality, eliminating unlawful discrimination and fostering good relations between people with particular protected characteristics and others. In producing guidance and advice, NICE aims to comply fully with all legal obligations to: promote race and disability equality and equality of opportunity between men and women, eliminate unlawful discrimination on grounds of race, disability, age, sex, gender reassignment, marriage and civil partnership, pregnancy and maternity (including women post-delivery), sexual orientation, and religion or belief (these are protected characteristics under the Equality Act 2010). Glaucoma is more common in older people, so they are more likely to benefit from ORA G3. Age is a protected characteristic under the Equality Act 2010. Clinical and technical evidence A literature search was carried out for this briefing in accordance with the interim process and methods statement. This briefing includes the most relevant or best available published evidence relating to the clinical effectiveness of the technology. Further information about how the evidence for this briefing was selected is available on request by contacting mibs@nice.org.uk. Page 4 of

Published evidence This briefing summarises 5 studies; 4 done in the US and 1 done in Korea, including a total of 635 adults with glaucoma (822 eyes). Three were prospective cohort studies (n=400) and 2 were retrospective studies (n=235). Table 3 summarises the clinical evidence as well as its strengths and limitations. Overall assessment of the evidence The results of all 5 studies suggest that corneal hysteresis is associated with the development and progression of glaucoma. Three studies also showed correlations between corneal hysteresis and corneal central thickness, and 2 studies showed correlations between corneal hysteresis and intraocular pressure. None of the studies was conducted in the UK so the results may not be generalisable to the NHS. The company claims that ORA G3 will benefit people with suspected glaucoma, as well as people with a confirmed diagnosis of glaucoma. However, only 1 of the studies (n=199) included people with suspected glaucoma. Prospective, controlled, UK studies that assess the value of measuring corneal hysteresis alongside standard of care would be useful. Table 3 Summary of selected studies Susanna et al. (2018) Study size, design and location parameters of interest A prospective observational cohort study of 199 adults (287 eyes) with suspected glaucoma in the US. CH IOP CCT Page 5 of

outcomes CH measurements at baseline were significantly lower in people who developed glaucoma compared with those that did not (9.5±1.5 vs 10.2±2.0 mmhg, p=0.012). Each 1 mmhg lower CH was associated with a 22% increase in the risk of developing glaucoma during follow-up (HR=1.22, 95% CI 1.04 to 1.41, p=0.013). In multivariable analysis, adjusted for age, IOP, CTT and PSD, CH was still predictive of glaucoma (HR=1.20, 95% CI 1.01 to 1.42, p=0.039). Strengths and limitations The study recruited a relatively large group of people but in a non-uk setting. Adults with suspected glaucoma were included. The patient population in other studies are people with established glaucoma. De Moraes et al. (2012) Study size, design and location parameters of interest A retrospective study of 153 adults with glaucoma (153 eyes) in the US. IOP CCT CH CRF IOPg IOPcc outcomes Eyes that had VF progression had lower CH compared with non-progressing eyes (7.5±1.4 vs 9.0±1.8 mmhg). There was a moderate and significant correlation between CH and CCT (r=0.33, p<0.01). In multivariate analysis, CH was the corneal parameter most strongly associated with VF progression (OR 1.55, CI 1.14 to 2.10, p<0.01). Strengths and limitations The study recruited a relatively large number of adults but in a non-uk setting. Zhang et al. (2016) Page 6 of

Study size, design and location parameters of interest A prospective observational cohort study of 133 adults with glaucoma (186 eyes) at a glaucoma centre in the US. CH CCT GAT IOP outcomes In univariate analysis, each 1 mmhg lower CH was associated with a 0.13 micrometre per year faster rate of RNFL loss (p=0.0). In multivariable analysis adjusting for age, race, average GAT IOP and CTT, CH was still associated with a faster rate of RNFL loss (p=0.015). CCT was not found to be associated with RNFL loss. Strengths and limitations The study recruited a relatively large number of people. A limitation of the study is that treatment was decided by the attending ophthalmologist and not standardised. Different treatment options may have influenced progression rates. Medeiros et al. (2013) Study size, design and location parameters of interest An observational cohort study of 68 adults with glaucoma (4 eyes) at a glaucoma centre in the US. CH GAT IOP CCT outcomes In univariable analysis, each 1 mmhg lower CH was associated with 0.25% per year faster rate of VF decline over time (p<0.001). In multivariable analysis the authors concluded that there were a significant interaction between IOP and CH. There was a relationship between CCT and CH (r=0.48, p<0.001). Strengths and limitations A relatively small number of adults was recruited into the study. Page 7 of

Park et al. (2015) Study size, design and location parameters of interest A retrospective cross-sectional observational study of 82 adults with NTG (82 eyes) at a glaucoma clinic in Seoul, Korea. IOP CCT CRF CH IOPg IOPcc outcomes 26 of 39 eyes with low CH had progression of VF damage compared with 15 of 43 eyes with high CH (p<0.01). In univariate and multivariable regression analysis CH was significantly correlated with VF progression (univariate beta=0.39, p<0.01, multivariable beta=0.32; p=0.01). CH had a moderate and significant correlation with CCT (r=0.44, p<0.01) and IOPcc (r= 0.52, p<0.01). Strengths and limitations Study participants were having anti-glaucoma medications. CH may have been increased by IOP-lowering therapy. A relatively small number of adults were recruited into the study. Abbreviations: CCT, central corneal thickness; CH, corneal hysteresis; CRF, corneal resistance factor; IOP, intraocular pressure; IOPcc, corneal compensated intraocular pressure; IOPg, Goldmann estimated intraocular pressure; PSD, pattern standard deviation; RNFL, retinal nerve fibre layer; VF, visual field. Recent and ongoing studies No ongoing or in-development trials were identified. Page 8 of

Specialist commentator comments Comments on this technology were invited from clinical specialists working in the field and relevant patient organisations. The comments received are individual opinions and do not represent NICE's view. All 5 specialist commentators were familiar with or had used ORA G3 before. Level of innovation One specialist commentator confirmed that ORA G3 is the only device that can measure corneal hysteresis, but noted that how well corneal hysteresis predicts glaucoma is unproven. Potential patient impact One specialist commentator remarked that if a well-conducted, prospective study did show that corneal hysteresis was a reliable risk factor for glaucoma it could lead to better patient outcomes, specifically: better detection of the disease, earlier treatment, and fewer assessments for people at low risk of development or progression. Another stated that ORA G3 may improve clinical outcomes by identifying people at high risk of development or progression through measuring corneal hysteresis. People determined to be at low risk would need fewer hospital visits and less treatment. Potential system impact The specialist commentators stated that if corneal hysteresis were proven to be a reliable risk factor for glaucoma, it would allow for more accurate targeted follow-up. This would mean less unnecessary treatment for people at lower risk. One specialist commentator said that because ORA G3 is an extra test, it will increase costs. However, they acknowledged that it has the potential to be cost saving over time. Another specialist commentator noted that ORA G3 could reduce the number of senior or specialist staff needed in a clinic. Because the device is relatively easy to use and does not need eye drops or contact with the eye, it can be used by more junior staff. Page 9 of

Another commentator suggested that ORA G3 could be used instead of current intraocular pressure measurement in primary and secondary care. General comments One specialist commentator felt that corneal hysteresis is not a proven risk factor for glaucoma. Another considered corneal hysteresis to be a risk factor but, thought that corneal compensated intraocular pressure was most useful clinically. A third specialist commentator did not think that corneal hysteresis was a risk factor but observed that it may be a helpful indicator for patients who cannot have some of the tests recommended by NICE. Another explained that they use corneal hysteresis as a marker for measurement error by Goldmann applanation tonometry, rather than a risk factor in itself. Two specialist commentators felt that as an extra device, finding space for ORA G3 in a clinic may be an issue. However, most of the commentators did not foresee any problems with space for the device. Specialist commentators The following clinicians contributed to this briefing: Mr Anthony Khawaja, consultant ophthalmic surgeon, Moorfields Eye Hospital. Mr Khawaja declared he has a pending honorarium for talking about the role of corneal hysteresis and corneal compensated intraocular pressure in glaucoma management at an optometric congress (100% Optical). The payment will be coming from Grafton Ophthalmics, which distributes ORA G3 in the UK. Mr Scott Fraser, consultant ophthalmologist, Sunderland Eye Infirmary. No conflicts of interest declared. Mr Simon Longstaff, consultant ophthalmologist, Royal Hallamshire Hospital. No conflicts of interest declared. Ms Helen Hobman, senior imaging technician, Hull Royal Infirmary. No conflicts of interest declared. Professor David Garway-Heath, honorary consultant ophthalmologist, Moorfields Eye Hospital. Professor Garway-Heath has evaluated ORA G3 as part of a clinical trial and presented the results as a poster at a conference. Page 10 of

Development elopment of this briefing This briefing was developed by NICE. The interim process and methods statement sets out the process NICE uses to select topics, and how the briefings are developed, quality-assured and approved for publication. ISBN: 978-1-4731-2975-7 Page of