Evaluation of occlusal relationship reproducibility with CAD/CAM techniques

Similar documents
Dimensional Accuracy of Optical Bite Registration in Single and Multiple Unit Restorations

Double-casting method for fixed prosthodontics with functionally generated path

Soft Tissue Transfer Utilizing Digital Impressions of Anterior Implants

Concepts of occlusion Balanced occlusion. Monoplane occlusion. Lingualized occlusion. Figure (10-1)

Original Article. Masako Yanagawa a, Kenji Fueki b and Takashi Ohyama c

Tooth preparation for posterior fi xed partial denture (FPD) Tooth preparation for anterior fi xed partial denture (FPD)

CAD/CAM restorative principles

Title. Citation 北海道歯学雑誌, 38(Special issue): Issue Date Doc URL. Type. File Information.

2015 Member Speaker Forum. Chair: L. Scott Brooksby, DDS, BS. Friday, October 23, :30 AM 3:45 PM. Coral Ballroom. 3.

Case Presentation PROSTHETIC PHASE

In vivo evaluation of three-dimensional of volumetric changes using a CAD/CAM chair-side system: Technical procedure

Occlusion & Prosthodontics

Occlusal status of implant superstructures at mandibular first molar immediately after setting

Alveolar Growth in Japanese Infants: A Comparison between Now and 40 Years ago

MAURO FRADEANI, MD, DDS

The manufacturing characterization of zirconia core copings of CAD/CAM systems

Infraocclusion Treated with Removable Prosthesis on Occlusal Surface of Severely Attritioned Teeth

Occlusal rehabilitation of posterior fixed prostheses: A clinical report

Dr Mohammed Alfarsi Page 1 9 December Principles of Occlusion

Prosthetic Options in Implant Dentistry. Hakimeh Siadat, DDS, MSc Associate Professor

Principle of Occlusion

Screw retained implant crown restoration with digital workflow using scan body and surgical guide

Diagnosis. overt Examination. Definitive Examination. History. atient interview. Personal History. Clinical Examination.

From planning to surgery: a totally digital working flow for Leone implants placement

Connect your Scanner to SomnoMed Canada. SOMGauge Protrusive Bite Recording - Manual. Scanning Impressions - Lower and Upper

Evaluation of the Accuracy of Six Intraoral Scanning Devices: An in-vitro Investigation September 25, 2015

Digital Impressions - A Review of Latest Technology in Dentistry

OCCLUSION: PHYSIOLOGIC vs. NON-PHYSIOLOGIC

Masticatory mandibular movements for different foods textures related to onomatopoetic words

Clinical evaluation of jacket crowns made of the Estenia indirect composite

Lect. 14 Prosthodontics Dr. Osama

Components Of Implant Protective Occlusion A Review

3Shape TRIOS Implant Scanning

Recent advances in composite CAD/CAM blocks

Prosthodontic Rehabilitation with Overdenture Using Modified Impression Technique: A Case Report

SCD Case Study. Implant-supported overdentures

Mandibular implant-supported hybrid prostheses

For technical assistance: Tel Working time: 8.30 am pm

Keeping Up With the Technology of Restorative Dentistry

OCCLUSION. Principles & Treatment. José dos Santos, Jr, DDS, PhD. São Paulo, Brazil

Creating low cost, functional dentures using a digital workflow and in-house printer

أ.م. هدى عباس عبد اهلل CROWN AND BRIDGE جامعة تكريت كلية. Lec. (2) طب االسنان

Life Science Journal 2013;10(4) Retention Force Measurement of Telescopic Crowns with Different Clearance Fit

Abstract. Comparison of two intraoral scanners. Meguru Yamamoto a Yu Kataoka b Atsufumi Manabe a. Article Type: Research Article

Case report: Lingualized occlusion -A better way for enhancing function & esthetic

Reproducibility of Interocclusal Recording for Mandibular Removable Partial Denture in Bilateral Distal Extension Cases

Oral splints come in a plethora

OCCLUSION IN NEWLY FABRICATED BRIDGE*

EFFECTIVE DATE: 04/24/14 REVISED DATE: 04/23/15, 04/28/16, 06/22/17, 06/28/18 POLICY NUMBER: CATEGORY: Dental

STANDARDS & GUIDELINES

Jaw relation registration in RPD

Case Report Prosthodontic Rehabilitation of the Patient with Severely Worn Dentition: A Case Report

Teaming Students Together To Evaluate Each Other's Cavity Preparation Using CAD/CAM Technology

Paper submission. Denture repair with the application of a magnetic attachment to the inner crown of a telescopic crown: A 3-year follow-up case

This PDF is available for free download from a site hosted by Medknow Publications

Reference to primary publication Properties of alginates in ZWP 4/2014 Xantalgin Crono - Introduction

The main challenge in using the natural dentition

Abstract. A Case Of External Resorption

MEDICAL UNIVERSITY OF VARNA FACULTY OF DENTAL MEDICINE DEPARTMENT OF PROSTHETIC DENTAL MEDICINE GOVERNMENT EXAMINATION SYLLABUS

Dental Anatomy and Occlusion

Full-coverage crown restorations on seven maxillary teeth and six mandibular teeth

Proposed score for occlusal-supporting ability

Integration of New Technology. Change

CAUSE OF TECHNICAL FAILURES OF CONICAL CROWN-RETAINED DENTURE (CCRD): A CLINICAL REPORT

Simplant. Guided Surgery. delivering restorative driven implant treatment

For many years, patients with

Application of ARCUS digma I, II systems for full mouth reconstruction: a case report

Restorations with CAD/CAM technology

STL. inside. ineos Blue: Precision, Speed and Control. THE SCANNER WITH Bluecam TECHNOLOGY

ACRYLIC REMOVABLE PARTIAL DENTURE(RPD)

The accuracy of the CAD system using intraoral and extraoral scanners for designing of fixed dental prostheses

White light scanner-based repeatability of 3-dimensional digitizing of silicon rubber abutment teeth impressions

Accuracy of the marginal fit of all-ceramic crowns fabricated by direct and indirect digital scanning methods

Restoration of the worn dentition

ISPUB.COM. Habitual Centric: A Case Report. Manisha, N Kathuria, A Gupta, N Gupta INTRODUCTION CASE REPORT

Occlusion and removable prosthodontics

Marginal Adaptation of Cerec 2 Ceramic Inlays after Cementation

ABSTRACT INTRODUCTION

Prosthodontic Management of Combination Syndrome Case with Metal Reinforced Maxillary Complete Denture and Mandibular Teeth supported Overdenture

Implant and Tooth Supported Full-Mouth Rehabilitation with Hobo Twin-Stage Technique

Digital Smile Design using the M Proportions and GPS 2D to 3D Digital Facebow: Clinical Case 1

A technique for fabricating patterns for removable partial. denture frameworks using digitized casts and electronic

Solid Zirconia Full-Arch Implant Prosthesis (Protocol C All-CAD with Multi-Unit Abutments) BruxZir. FIRST Appointment. The BruxZir

GuidedService. The ultimate guide for precise implantations

Case Report Total CAD/CAM Supported Method for Manufacturing Removable Complete Dentures

Prof. Trimurni Abidin, drg.,m.kes.,sp.kg(k) Department of Conservative Dentistry Faculty of Dentistry University of Sumatera Utara 2013

6610 NE 181st Street, Suite #1, Kenmore, WA

Occlusal Principles and Considerations for Implants: An Overview

Occlusion in complete denture

Element-Z Screw-Retained Hybrid

ISO Dentistry Digitizing devices for CAD/CAM systems for indirect dental restorations Test methods for assessing accuracy

Development of the Computerized Dental Cast Form Analyzing System -Three Dimensional Diagnosis of Dental Arch Form and the

VITA ENAMIC Implant Solutions Clinically Proven Force Absorption for Prosthetic and Implant Success

Cleft lip and palate; oronasal istula; prosthetic treatment; O ring attachment

Active Clinical Treatment Case 48

Arrangement of the artificial teeth:

Oral Rehabilitation with CAMLOG implants after loss of dentition due to an accident

Simultaneous replacement of maxillary central incisors with Cerec biogeneric reference technique: A case report

Sho Kayumi 1,2, Yoshiyuki Takayama 1*, Atsuro Yokoyama 2 and Nana Ueda 1

Annotation to the lesson 21 Topic: Methods of provisory crowns fabrication. Chair-side technique. Evaluation of

Transcription:

Evaluation of occlusal relationship reproducibility with CAD/CAM techniques Yoji Ueda, DDS, a Daizo Okada, DDS, PhD, a Reiko Ogura, DDS, PhD, a Wataru Komada, DDS, PhD, a Shiho Otake, DDS, PhD, a Masaomi Ikeda, RDT, BSc, PhD, b and Hiroyuki Miura, DDS, PhD a a Fixed Prosthodontics, Department of Restorative Sciences, Graduate School, Tokyo Medical and Dental University, and b Clinical Oral Science, Department of Oral Health Care Sciences, Faculty of Dentistry, Tokyo Medical and Dental University, Tokyo, Japan Purpose: The objective of this study was to evaluate the reproducibility of determining the area of the occlusal contact regions by CAD software. Materials and Methods: Nine subjects were recruited. The maxillary right first molars were the subject teeth. Optical impressions were taken six times. An optical impression of each antagonist was taken once. For optical bite registration, optical impressions from the buccal side during clenching were taken six times. The occlusal contact regions obtained by optical impressions and optical bite registration were represented using CAD software. The variabilities derived from changes in optical impressions were compared with those derived from changes in optical bite registration. Results: The variability of the area of the clearance region depending on changes in optical bite registration was significantly higher than that depending on changes in optical impressions. Conclusion: It was demonstrated that changes in optical bite registration affected the reproducibility of the area of the clearance region. (Asian Pac J Dent 2014; 14: 35-40.) Key Words: CAD/CAM, occlusal contact, optical impression, reproducibility Introduction The technique of computer-aided design/computer-aided manufacturing (CAD/CAM) has evolved by way of improvements in the measuring system, processing technique, and software. of CAD/CAM ceramic restorations have reported survival rates of over 85% after 10 years. 1,2 Long-term prospective studies More recently, CAD/CAM systems have been introduced that incorporate a new optical bite registration method to determine the occlusal relationship between the abutment tooth and its antagonist using CAD software. With these systems, an intraoral camera can be utilized for optical bite registration as well as optical impressions of the dentition. Optical bite registration is based on optical impressions of the buccal surface of the dentition from the buccal side during clenching at the intercuspal position, without any bite registration materials. 3,4 These optical impression data are used to fabricate restorations at the chair-side, and it is possible to replace the restorations on the same day. 5 In prosthodontic treatment, the shape and function of the prosthesis must be harmonized with the stomatognathic system to maintain good functional condition for a long time after the treatment. 6 Many studies have reported that teeth were moved in function, that is, the amount and direction of tooth displacement and the occlusal relationship between the maxillary and mandibular dentition were changed, depending on the biting force. 6-11 The occlusal relationship between the abutment tooth and its antagonist during clenching at the intercuspal position in vivo differed from the occlusal relationship calculated by CAD software. Moreover, optical powder must be applied to the occlusal surfaces to make the dentition visible to the intraoral camera. 12 Therefore, data from optical impressions cannot duplicate the actual dentition precisely, because of the thickness of the optical powder covering the occlusal surfaces. Although previous studies 13 have evaluated the accuracy of optical bite registration in the context of resin models, few have evaluated it in the context of actual dentition 35

in vivo. Additionally, it has been reported that the occlusal surface is closely related to masticatory efficiency, the main occluding area, and tooth displacement in function. 7,14-18 Therefore, to fabricate prostheses with functional occlusal surfaces using CAD/CAM systems, it is important that CAD software duplicate the occlusal relationship between the maxillary and mandibular dentition in vivo with high precision. The objective of this study was to evaluate the reproducibility of determining the area of the occlusal contact regions of the maxillary and mandibular dentition by CAD software. Materials and Methods The surfaces of the subject tooth and adjacent teeth were air-dried, then sprayed with titanium oxide powder (Cerec Optispray, Sirona, Bensheim, Germany) uniformly. Optical impressions were taken using an intraoral camera (Cerec Blue-CAM, Sirona) and recorded via CAD software (Cerec AC, Sirona). These procedures were performed six times (P1-P6). An optical impression of each antagonist was taken and recorded only once (Q). For optical bite registration, optical impressions from the buccal side during clenching with moderate biting force at the intercuspal position were taken using the intraoral camera and recorded via CAD software. These procedures were performed six times (BS1-BS6). The occlusal contact regions obtained by optical impressions and optical bite registration were represented using CAD software. The occlusal contact regions were divided into several groups based on the distance between the maxillary and mandibular occlusal surface; specifically, light-blue-colored regions (within 100 µm of the close contact, A), green-colored regions (0-50 µm of the penetrated contact, B), yellow-colored regions (50-100 µm of the penetrated contact, C), and red-colored regions (over 100 µm of the penetrated contact, D) (Fig. 1). Fig. 1 The occlusal contact regions were divided into several groups based on the distance between the maxillary and mandibular occlusal surfaces. dark-blue-colored regions (100-1000 µm of the close contact) not evaluated in this study light-blue-colored regions (within 100 µm of the close contact, A) green-colored regions (0-50 µm of the penetrated contact, B) yellow-colored regions (50-100 µm of the penetrated contact, C) red-colored regions (over 100 µm of the penetrated contact, D). Results The results derived from each subject are shown (Table 1). The variability of the area of the clearance region depending on changes in optical bite registration was significantly higher than that depending on changes in the optical impressions (p<0.05) (Fig. 2). Conversely, the variability of the area of the penetration region depending on changes in optical bite registration did not differ significantly from the variability of the area of the penetration region depending on changes in the optical impressions. As shown in a representative example of the results, the location of the occlusal contact regions among the sequence of the results in the same subjects was almost the same, when optical impressions or optical bite registration were changed (Fig. 3). However, there were some differences in the areas of each occlusal contact region. 36

Ueda et al. Asian Pac J Dent 2014; 14: 35-40 Table 1. The variability of the area of the clearance and penetration regions depending on changes in optical impression and optical bite registration (mm²) Subject A B C D E F G H I Mean Clearance Penetration SD Optical impression 1.17 0.37 0.79 0.46 0.38 1.4 0.04 0.33 0.81 0.64 0.44 Optical bite registration 2.18 0.27 0.39 0.74 0.35 2.88 0.05 0.17 1.77 0.98 1.03 Optical impression 1.01 0.56 0.32 1.43 0.65 0.36 0.99 0.06 0.28 0.63 0.44 Optical bite registration 1.1 1.32 0.27 1.6 0.49 0.58 1.51 0.13 0.49 0.83 0.56 Fig. 2 The variability of the area of the clearance (a) and penetration (b) regions depending on changes in optical impression and optical bite registration Fig. 3 A representative example of the results in the same subject P1, Q with BS1 (a), P1, Q with BS2 (b), P1, Q with BS3 (c), P1, Q with BS4 (d), P1, Q with BS5 (e), P1, Q with BS6 (f), P2, Q with BS1 (g), P3, Q with BS1 (h), P4, Q with BS1 (i), P5, Q with BS1 (j), P6, Q with BS1 (k) Discussion The variability of the area of the clearance region depending on changes in optical bite registration was significantly higher than that depending on changes in the optical impressions. variability was the non-uniform thickness of the optical powder. 37 One of the reasons for this The scanning area for the optical impressions

was larger than that for optical bite registration. In other words, the optical impressions required a larger powdered area than was required for optical bite registration. It has previously been reported 19 that the precision of the intraoral camera of this system was only 19 µm in the context of a stone cast, therefore, the precision of the intraoral camera and the thickness of the optical powder had an insignificant effect on the precision of this system considering the values of the clearance and penetration regions. Moreover, given the acceptable range of the occlusal height of crown restorations, threshold level of the periodontal ligament, 20 and the accuracy of crown restorations fabricated with indirect methods, the precision value of 19 µm was considered acceptable. Based on an in vitro study, Iwaki et al. 13 reported that with CAD/CAM systems, the optical bite registration method provided better dimensional accuracy in the interarch relationship in comparison with the conventional physical registration. However, in the context of actual dentition the precision of the optical impressions is affected by numerous factors including a lack of space for inserting an intraoral camera, movement of patients during taking the optical impressions, saliva, and humidity. 21 Therefore, it is important to evaluate the precision of optical bite registration in vivo. In this study, the variability of the area of the clearance region depending on changes in optical bite registration was significantly higher than that depending on changes in the optical impressions. These results may have been caused by the difference in the occlusal relationship between the maxillary and mandibular molars during clenching at the intercuspal position. The difference was caused by a difference in the direction of tooth displacement, rather than the amount of tooth displacement. The stress-strain curve (SSC) represented the relationship between the amount of tooth displacement and the biting force 11. The SSC of the maxillary molar showed two-phase, with the first phase mainly caused by distortion of the periodontal ligament and the second phase representing distortion of the alveolar bone in addition to the periodontal ligament. In the first phase, the maxillary molar was substantially displaced in the apical direction with a slight biting force, approximately 5 N. Conversely, in the second phase, the molar was displaced only slightly, regardless of the increase in the biting force. In this study, optical bite registration was taken during clenching with moderate biting force at the intercuspal position. Therefore, in the case of each optical bite registration, the differences in the amount of tooth displacement of the molars may have been slight. However, even with moderate biting force, the tooth was not only translated but also rotated in function, and the occlusal relationship between the maxillary and mandibular molars was easily changed because these molars were moved in the lingual direction with rotation. In function, the maxillary first molar is displaced approximately 100 to 150 µm in the palatal apical direction with rotation, while the mandibular first molar is displaced approximately 50 to 100 µm in the lingual direction with rotation. 6-11 Thus, the occlusal relationship between the maxillary and mandibular dentition is easy to change, and in the context of CAD software, the occlusal contact regions were also easy to change depending on slight differences in the biting force. Moreover, the buccal side optical bite registration data were less informative than optical impression data of the occlusal surface because the buccal surface was smoother than the occlusal surface, 22 and so the variability of the area of the clearance region depending on changes in optical bite registration was higher than that depending on changes in the optical impressions. Given high variability, it may be difficult to duplicate the occlusal surface of the dentition and the occlusal relationship between the maxillary and mandibular dentition with high precision using CAD software. Therefore, it may not be possible to fabricate prostheses with adequate occlusal contact, and there is a possibility 38

that prostheses with excessive high occlusal contact or inadequate occlusal contact may be fabricated. In the case of excessive high occlusal contact of prostheses, occlusal trauma or changes in the sensation threshold of the dental pulp may occur. 20,23-26 In the case of inadequate occlusal contact, disuse atrophy of the periodontal ligament and extrusion of the tooth may occur. It is very important to fabricate prostheses with adequate close contact (the clearance region defined in this study), as well as adequate actual occlusal contacts on the occlusal surface, to maintain good functional condition for a long time. Recently, it was reported 7,14-18,27,28 that close occlusal contacts had a strong influence on masticatory efficiency, the stability of the main occluding area, and the formation of Squeezing Room at the latest stage of mastication. It was demonstrated that changes in optical bite registration affected the reproducibility of the area of the clearance region in this study. To fabricate prostheses with functional occlusal surfaces using CAD/CAM systems, it is important that optical bite registration is performed with high precision. Further development of CAD/CAM systems is expected. The variability depending on changes in optical bite registration was significantly higher than that depending on changes in the optical impressions in the clearance region that was closely related to fabrications of prostheses with functional occlusal surfaces even though there was no significant difference in the penetration region. Acknowledgment This study was partly supported by Grant-in-Aid for Scientific Research from the Japanese Society for the Promotion of Science (No. 24792061). References 1. Sjögren G, Molin M, van Dijken JWV. A 10-year prospective evaluation of CAD/CAM-manufactured (Cerec) ceramic inlays cemented with a chemically cured or dual-cured resin composite. Int J Prosthodont 2004; 17: 241-6. 2. Zimmer S, Göhlich O, Rüttermann S, Lang H, Raab WHM, Barthel CR. Long-term survival of Cerec restorations: A 10-year study. Oper Dent 2008; 33: 484-7. 3. Müller HC. Registration of occlusion by buccal scan in Cerec software version 3.80. Int J Comput Dent 2010; 13: 265-73. 4. Frank E, Frank S. Bite registration in Cerec and inlab. Int J Comput Dent 2012; 15: 149-58. 5. Van Noort R. The future of dental devices is digital. Dent Mater 2012; 28: 3-12. 6. Picton DC. Vertical movement of cheek teeth during biting. Arch Oral Biol 1963; 8: 109-18. 7. Behrend DA. Patterns of tooth displacement in simulated chewing cycles in man. Arch Oral Biol 1978; 23: 1089-93. 8. Masuda T, Miura H, Kato H, Furuki Y, Hasegawa S. Distortion of periodontal tissue in maxillary molar region during biting-measurement with quasi three-dimensional method. Dent Jpn 1998; 34: 54-8. 9. Miura H, Hasegawa S, Okada D, Ishihara H. The measurement of physiological tooth displacement in function. J Med Dent Sci 1998; 45: 103-15. 10. Okada D. Teeth displacements and occlusal contacts depending on clenching force -intercuspal position-. J Jpn Prosthodont Soc 1998; 42: 1013-23. 11. Amarsaikhan B, Miura H, Okada D, Masuda T, Ishihara H, Shinki T, et al. Influence of environmental factors on tooth displacement. J Med Dent Sci 2002; 49: 19-26. 12. Kurbad A. The optical conditioning of Cerec preparations with scan spray. Int J Comput Dent 2000; 3: 269-79. 13. Iwaki Y, Wakabayashi N, Igarashi Y. Dimensional accuracy of optical bite registration in single and multiple unit restorations. Oper Dent 2013; 38: 309-15. 14. Wilding RJ. The association between chewing efficiency and occlusal contact area in man. Arch Oral Biol 1993; 38 589-96. 15. Kato H, Furuki Y, Hasegawa S. Observations on the main occluding area in mastication. J Jpn Soc Stomatognath Funct 1996; 2: 119-27. 16. Tokuda A, Kato H, Miura H, Okada D, Hoshino K, Hasegawa S. The main occluding area in consideration of the occlusal relation. J Jpn Soc Stomatognath Funct 2006; 13: 31-7. 17. Nakatsuka Y, Yamashita S, Nimura H, Mizoue S, Tsuchiya S, Hashii K. Location of main occluding areas and masticatory ability in patients with reduced occlusal support. Aust Dent J 2010; 55: 45-50. 18. Wang M, Mehta N. A possible biomechanical role of occlusal cusp-fossa contact relationships. J Oral Rehabil 2013; 40: 69-79. 19. Mehl A, Ender A, Mörmann W, Attin T. Accuracy testing of a new intraoral 3D camera. Int J Comput Dent 2009; 12: 11-28. 20. Ikeda T. Influence of occlusal overload on tooth sensation and periodontal tissue. J Jpn Prosthodont Soc 1987; 31: 675-88. 21. Rudolph H, Luthardt RG, Walter MH. Computer-aided analysis of the influence of digitizing and surfacing on the accuracy in dental CAD/CAM technology. Comput Biol Med 2007; 37: 579-87. 22. Jaschouz S, Mehl A. Reproducibility of habitual intercuspation in vivo. J Dent 2014; 42: 210-8. 39

23. Kvinnsland S, Kristiansen AB, Kvinnsland I, Heyeraas KJ. Effect of experimental traumatic occlusion on periodontal and pulpal blood flow. Acta Odontol Scand 1992; 50: 211-9. 24. Ikeda T, Nakano M, Bando E, Suzuki A. The effect of light premature occlusal contact on tooth pain threshold in humans. J Oral Rehabil 1998; 25: 589-95. 25. Katona TR. A mathematical analysis of the role of friction in occlusal trauma. J Prosthet Dent 2001; 86: 636-43. 26. Nozaki K, Kaku M, Yamashita Y, Yamauchi M, Miura H. Effect of cyclic mechanical loading on osteoclast recruitment in periodontal tissue. J Periodontal Res 2010; 45: 8-15. 27. Watabe A. Changes of interocclusal contacts and clearance between opposing upper and lower molars during lateral excursions. J Jpn Prosthodont Soc 1995; 39: 517-29. 28. Abe S. A kinetic analysis of occlusal contacts during masticating chewing-gum. J Jpn Prosthodont Soc 2000; 44: 274-83. Correspondence to: Dr. Daizo Okada Fixed Prosthodontics, Department of Restorative Sciences, Graduate School, Tokyo Medical and Dental University 1-5-45, Yushima, Bunkyo-ku, Tokyo 113-8549, Japan Fax: +81-3-5803-0201 E-mail: d.okada.fpro@tmd.ac.jp Accepted November 18, 2014. Copyright 2014 by the Asian Pacific Journal of Dentistry. Online ISSN 2185-3487, Print ISSN 2185-3479 40