PROCEDURE MANUAL. Procedure: CLIA Complexity: Waived for Whole Blood, Moderate for Serum, Plasma. Prepared By Date Adopted Supersedes Procedure #

Similar documents
FOR INFORMATIONAL USE ONLY

NEGATIVE POSITIVE. Rev , 06/11. 5 min. Mono Test. For fi ngertip. blood: 1 DROP 1 DROP For serum, whole blood. plasma or. samples.

Mono Test 1 DROP 1 DROP. For fingertip blood: For serum, plasma or whole blood samples in tubes: Rev , 05/09

PROCEDURE MANUAL. Prepared By Date Adopted Supersedes Procedure # Review Date Revision Date Signature

CLIA Complexity for Whole Blood: WAIVED. Intended Use. Summary and Explanation

CLIA Complexity: WAIVED INTENDED USE SUMMARY AND EXPLANATION

Catalog # 0W009 0W010 Test Cassettes, murine monoclonal antibody to human IgG (Test Line) and rabbit polyclonal antibody (Control Line)

Catalog # 0W009 0W010 Test Cassettes, murine monoclonal antibody to human IgG (Test Line) and rabbit polyclonal antibody (Control Line) Reagents

Step-by-Step Instructions For OraQuick HCV Rapid Antibody Test

CLIA Complexity: Waived

Infectious Mononucleosis IM Cassette Test RAPU04A830

CLIA Complexity: WAIVED

Doc#: ASI COLOR MONO II TEST

CLIA Complexity: WAIVED

HAV IgG/IgM Rapid Test

ANTIBODY SCREENING by Uni-Gold Recombigen HIV

Cotinine (Mouse/Rat) ELISA Kit

Malaria Pf/pan antigen Rapid Test

CDIA TM Rubella IgG/IgM Rapid Test Kit

Hepatitis C Virus (HCV) Antibody Test

Unigold Recombigen HIV 1/2 Training for HIV Testing Sites. Updated: February 2018 Cicely Richard Office of HIV/AIDS

QUICK REFERENCE INSTRUCTIONS. THYROCHEK TSH Cassette

DETERMINE SPECIMEN REQUIREMENTS HIV-1/2 Ag/Ab Combo TESTING PROCEDURE

WHO Prequalification of In Vitro Diagnostics PUBLIC REPORT. Product: OraQuick HIV 1/2 Rapid Antibody Test WHO reference number: PQDx

WHO Prequalification of In Vitro Diagnostics PUBLIC REPORT. Product: OraQuick HIV 1/2 Rapid Antibody Test WHO reference number: PQDx

Rotavirus Test Kit. Instructions For Use. Format: Cassette Specimen: Fecal Extract Catalog Number: VEL-001-ROTA

PROCEDURE MANUAL. Prepared By Date Adopted Supersedes Procedure # Review Date Revision Date Signature

Rubella Latex Agglutination Test

Malaria Combo Test Kit

Triiodothyronine (T3) ELISA

QUICK REFERENCE INSTRUCTIONS

Mouse/Rat THYROXINE (T4) ELISA Catalog No (96 Tests)

TESTS, REF TESTS)

NEPHROCHECK Calibration Verification Kit Package Insert

HBeAg and HBeAg Ab ELISA Kit

DIAGNOSTIC AUTOMATION, INC.

WHO Prequalification of In Vitro Diagnostics PUBLIC REPORT. Product: DPP HIV 1/2 Assay WHO reference number: PQDx

See external label 2 C-8 C 96 tests Chemiluminescence. CMV IgM. Cat # Diluted samples, controls & calibrator 100 µl 30 minutes

Treponema Pallidum (TP) Antibody Test

HAV IgM Rapid Test(Cassette)

Influenza A & B Screening

NEPHROCHECK Liquid Control Kit Package Insert

H. pylori IgM CLIA kit

USO PROFESSIONALE PROFESSIONAL USE

Human Cytomegalovirus IgM ELISA Kit

H.Pylori IgG

This kit is intended for Research Use Only. Not for use in diagnostic procedures.

WHO Prequalification of Diagnostics Programme PUBLIC REPORT

QUICK REFERENCE INSTRUCTIONS For use with Sofia and Sofia 2. Rx only

T3 (Total) (Mouse/Rat) ELISA Kit

H. pylori IgM. Cat # H. pylori IgM ELISA. ELISA: Enzyme Linked Immunosorbent Assay. ELISA - Indirect; Antigen Coated Plate

Hepatitis A virus IgM ELISA Kit

Helicobacter pylori Antigen Test

Toxoplasma gondii IgM (Toxo IgM)

H.Pylori IgG Cat # 1503Z

Dengue IgG/IgM/NS1 Combo Rapid Test Device

Insulin (Porcine/Canine) ELISA

NCCLS. Accutest H. pylori WB Test. (Catalog. No. ID-92A225) For Professional and In Vitro Diagnostic Use Only

Herpes Simplex Virus 2 IgM HSV 2 IgM

25(OH) Vitamin D ELISA (BD-220BA), 192 Tests

Strep-a-Test Twister Test

H.Pylori IgM Cat # 1504Z

Human Cytomegalovirus Virus (CMV) IgG ELISA Kit

Effective Date: 09/08 Supersedes Revision/Date: Original Revision: 09/08 Date Adopted:

Sofia Lyme FIA. For use with Sofia Analyzer only CLIA Complexity: Moderate for serum and plasma specimens

TB LAM Ag Lateral Flow Assay Standard Operating Procedure

Bovine Insulin ELISA

Anthrax protective antigen IgG ELISA Kit

Helicobacter pylori IgA ELISA Kit

Thyroid Stimulating Hormone (TSH) ELISA Catalog No. GWB , legacy id (96 Tests)

See external label 96 tests HSV 2 IgA. Cat #

Chlamydia Rapid Screen Test (RAP-2858) RUO in the USA. Revised 28 Jul 2006

Chlamydia trachomatis (CHLa)Test Kit

A rapid test for the qualitative detection of Malaria pf and pv antigen in human blood sample

Human Influenza A (Swine Flu) Rapid test

Influenza A IgG ELISA

Toxoplasma gondii IgM ELISA Kit

CYTOMEGALOVIRUS (CMV) IgM ELISA Kit Protocol

HSV-1 IgM ELISA. Catalog No (96 Tests) For Research Use Only. Not for use in Diagnostic Procedures.

H.pylori IgA Cat #

Toxoplasma gondii IgM ELISA Kit

See external label 2 C-8 C 96 tests CHEMILUMINESCENCE. CMV IgG. Cat # Step (20-25 C Room temp.) Volume

Mycoplasma pneumoniae IgG ELISA Kit

Rapid-VIDITEST. Strep A Blister. One step Strep A Blister for the detection of Group A Streptococcal antigen from throat swabs or culture.

FOR USE WITH SOFIA. For in vitro diagnostic use.

EBV-EA IgG. Cat # 1415Z. EBV -EA IgG ELISA. ELISA: Enzyme Linked Immunosorbent Assay. ELISA - Indirect; Antigen Coated Plate

Porcine/Canine Insulin ELISA

Rat Insulin ELISA. For the quantitative determination of insulin in rat serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Herpes Simplex Virus 2 IgG HSV 2 IgG

See external label 2 C-8 C Σ=96 tests Cat # 1505Z. MICROWELL ELISA H.Pylori IgA Cat # 1505Z

Human HBcAb IgM ELISA kit

Rapid-VIDITEST Swine Flu

For use with Sofia 2 CLIA Complexity: Waived for Finger-stick Whole Blood

Rapid-VIDITEST. Influenza A+B

HIV-1 p24 ELISA Kit. Catalog Number KA assays Version: 06. Intended for research use only.

HIV-1 p24 ELISA Kit. Cat.No: DEIA10155 Lot. No. (See product label) Size. Storage. Principle Of The Test. Reagents And Materials Provided

Rapid-VIDITEST. Astrovirus Card

Human HIV (1+2) antigen&antibody ELISA Kit

Measles IgM ELISA Kit

To provide you with necessary knowledge and skills to accurately perform 3 HIV rapid tests and to determine HIV status.

Transcription:

Procedure #: Procedure: CLIA Complexity: Waived for Whole Blood, Moderate for Serum, Plasma Prepared By Date Adopted Supersedes Procedure # Review Date Revision Date Signature Distributed to # of Copies Distributed to # of Copies This Procedural Bulletin is intended to provide a ready outline reference for performance of the assay. These abbreviated directions for use are not intended to replace the complete package insert. It is the obligation of every manufacturer of medical devices labeled FOR IN VITRO DIAGNOSTIC USE to provide a complete package insert in accordance with FDA labeling regulation (21 CFR 809.10). Prepared in accordance with the guidelines recommended by the Clinical and Laboratory Standards Institute, Wayne, PA 19087; CLSI Document GP2-A2. Quidel Corporation provides CLSI procedures for your use. The procedures are required to include the same information as listed in the package insert. Any modifications to this document are the sole responsibility of the Laboratory. Catalog Number: 20121 (20-Test kit) Page 1 of 16

ared By Date Adopted Supersedes Procedure # INTENDED USE QuickVue+ Infectious Mononucleosis test is a rapid Color lmmunochromatographic Assay (CICA) for the detection of Infectious Mononucleosis lgm heterophile antibodies in serum, plasma or whole blood. This test is intended for use as an aid in the diagnosis of Infectious Mononucleosis. For use by healthcare professionals. SUMMARY AND EXPLANATION Infectious Mononucleosis (IM) is usually a self-limiting disease that is caused by the Epstein-Barr Virus (EBV). 1,2 The most common symptoms are fatigue, pharyngitis, fever, lymphadenopathy, splenomegaly and hepatitis. 3 In rare cases, complications may develop including severe thrombocytopenia, hemolytic anemia, pericarditis, myocarditis, pneumonitis, Reye s syndrome, encephalitis and other neurological syndromes. In industrialized countries, the peak incidence of IM occurs between 14 and 18 years of age. In developing or densely populated countries, most children become infected before 3 years of age and symptoms may be mild or clinically inapparent. 4,5 During the acute phase of illness, certain heterophile antibodies appear in 85 90% of IM cases. These antibodies, known as IM heterophile antibodies, are primarily of the lgm class. 6,7 IgM to the viral capsid antigen appears early in infection and disappears within 4 to 6 weeks. IgG to the viral capsid antigen appears in the acute phase, peaks at 2 to 4 weeks after onset, declines slightly, and then persists for life. 8 Although the exact mechanism leading to IM heterophile antibody expression has not been determined, the antibodies are specifically associated with the disease. The IM heterophile antibodies are usually demonstrable one week after the onset of illness, peak at two to four weeks, and decline to low levels by 12 weeks. 2 Heterophile antibodies have been detected in patients serum over one year after the onset of illness. 9 Reliable laboratory diagnosis of IM has been performed for over fifty years based on the detection of IM heterophile antibodies. These heterophile antibodies are directed against antigens found in bovine, sheep and horse erythrocytes (QuickVue+ Infectious Mononucleosis test utilizes an extract of bovine erythrocytes which gives a greater sensitivity and specificity than similar extracts prepared from sheep and horse erythrocytes). 10,11 The Forssman antibody, which can interfere with some IM heterophile antibody assays, 7 does not interfere with the QuickVue+ Infectious Mononucleosis test. Catalog Number: 20121 (20-Test kit) Page 2 of 16

PRINCIPLE OF THE TEST The QuickVue+ Infectious Mononucleosis test assay uses Color lmmunochromatographic Assay (ClCA) technology for the qualitative detection of human heterophile IM antibodies (lgm class) in serum, plasma or whole blood. The Reaction Unit consists of a plastic housing containing a membrane strip which provides the solid support for the immunochromatographic assay. The right end of the membrane provides contact with the sample well. The sample well contains an absorbent pad which provides an even flow of the sample fluid (from right to left ) along the membrane. The first zone of the membrane (which is covered by the Reaction Unit label) is coated with blue latex beads that are conjugated to goat anti-human lgm antibodies (antibody-blue latex). Two agents are immobilized on the second zone of the membrane, which is exposed in the Read Result window. These agents include blue latex beads (non-conjugated) immobilized on the membrane to provide a pre-printed blue horizontal line. The second agent is a bovine erythrocyte extract, which is immobilized on the vertical line. The third zone of the membrane (exposed in the Test Complete window) contains an agent capable of binding the antibody blue latex to provide the vertical Test Complete line. An absorbent pad is situated at the left end of the membrane to retain fluid after the reaction is completed. A drying agent is enclosed in the Reaction Unit to stabilize the reactive agents. In the Test Procedure, serum, plasma or whole blood is added to the Add well, followed by the addition of the Developer. As the sample/developer fluid moves by capillary action across the first zone of the membrane, it mobilizes the antibody-blue latex. The fluid continues to move the antibody-blue latex across the membrane to the immobilized bovine erythrocyte extract (antigen) zone. If the specific IM heterophile antibodies are present in the sample, a sandwich of solid phase/im antibody/antibodyblue latex is formed. The vertical line will appear resulting in a positive sign (+) visible in the Read Result window, which indicates the presence of IM heterophile antibody. If the antibody is not detected, the Read Result window will only contain the preprinted blue horizontal line, indicating a negative ( ) result. As the fluid continues to move the antibody-blue latex across the membrane, it comes in contact with the reagent in the Test Complete window. A blue line will appear, indicating the test is complete. REAGENTS AND MATERIALS PROVIDED Each QuickVue+ Infectious Mononucleosis test kit contains enough reagents and materials for 20 tests. 1. Reaction Units (20): Test strip contains anti-human lgm and immobilized extracted bovine erythrocyte antigens. 2. Developer (5 ml): Detergent, 0.2% sodium azide. 3. Mono Negative Control (1 ml): Normal human serum diluted in saline solution, 0.2% sodium azide. Catalog Number: 20121 (20-Test kit) Page 3 of 16

4. Mono Positive Control (1 ml): IgM heterophile antibody positive human plasma diluted in saline solution, 0.2% sodium azide. 5. Sample Pipettes (20) 6. Capillary Tubes (20) 7. Package Insert (1) 8. Procedure Card (1) MATERIALS REQUIRED BUT NOT PROVIDED 1. Vacutainer tubes: EDTA, heparin, or citrate for plasma and venipuncture whole blood procedure. 2. Finger Lancet for fingertip blood procedure. 3. Centrifuge. WARNINGS AND PRECAUTIONS For in vitro diagnostic use. DO NOT use after expiration date. DO NOT mix components from different lots or different kits. Use appropriate precautions in the collection, storage, handling and disposal of patient samples and used kit contents. Use of Nitrile or Latex gloves is recommended when handling patient samples. 12 Dispose of containers and unused contents in accordance with Federal, State, and Local requirements. DO NOT interchange caps among reagents. Warning: Potential Biohazardous Material Each donor unit of human serum or plasma used in the preparation of the Positive and Negative Controls was tested by an FDA-licensed method for the presence of the antibody to human immunodeficiency virus type HIV-1/HIV-2, as well as hepatitis B surface antigen (HBsAg) and anti-hcv, and found to be negative. Nevertheless, caution should be used in handling and disposing of these items at biosafety level 2, Catalog Number: 20121 (20-Test kit) Page 4 of 16

as recommended in the Centers for Disease Control/National Institutes of Health Manual, Biosafety in Microbiological and Biomedical Laboratories, 2007. To obtain accurate results, you must follow the Package Insert instructions. KIT STORAGE AND STABILITY Store kit at room temperature 59 86 F (15 30 C), out of direct sunlight. Kit contents are stable until the expiration date printed on the outer box. Do not freeze. SAMPLE COLLECTION AND STORAGE 1. Serum, plasma or whole blood (including fingertip blood) can be used. Specimens must be collected in a manner appropriate for laboratory testing. 2. Whole blood containing EDTA, heparin, or citrate as an anti-coagulant may be used immediately without centrifugation; or may be stored at 2 8 C for up to 72 hours. 3. Fingertip blood should be tested immediately after the sample is taken. 4. Plasma samples containing EDTA, heparin, or citrate as an anti-coagulant can be used. 5. Serum or plasma samples can be stored at 2 8 C for up to 72 hours, or below -20 C (-4 F) for three months. Samples should not be repeatedly frozen and thawed. Thawed samples should be inverted several times just prior to testing. 6. Whole blood samples in which cell lysis has occurred will cause a red background to appear in the Read Result window. However, the result remains valid. Recommendations for Whole Blood Fingertip Sampling: Wash patient s hand with soap and warm water or clean with an alcohol swab. Allow to dry. Massage the hand without touching puncture site by rubbing down the hand and finger towards the tip. The side of the middle or ring finger is the preferred puncture site. Puncture the skin with the lancet. Wipe away first sign of blood. Gently rub the hand from wrist to palm to finger in order to form a rounded drop of blood over the puncture site. Avoid squeezing around the puncture site. Catalog Number: 20121 (20-Test kit) Page 5 of 16

For Hanging Drop Sampling: position the finger so that the drops of blood are just above the center of the Add well of the Reaction Unit. For Capillary Tube Sampling: touch the capillary tube to the blood until filled. QUALITY CONTROL External Quality Control External controls may also be used to demonstrate that the reagents and assay procedure perform properly. Quidel recommends that positive and negative controls be run once for each untrained operator, once for each new shipment of kits provided that each different lot received in the shipment is tested and as deemed additionally necessary by your internal quality control procedures, and in accordance with local, state, and federal regulations or accreditation requirements. External Positive and Negative Controls are provided in the kit. External Positive Control: Put one drop of Positive Control in the Add well. Put five drops of Developer in the Add well. Process the control as you would a patient sample. A positive signal is indicated by a vertical blue line in the Read Result window, resulting in a positive sign (+). External Negative Control: Put one drop of Negative Control in the Add well. Put five drops of Developer in the Add well. Process the control as you would a patient sample. A negative signal is indicated by a horizontal blue line ( ), in the Read Result window. Internal Quality Control Internal Positive Procedural Control: A blue line in the Test Complete window is considered an internal positive procedural control. If the test has been performed correctly and the Reaction Unit is working properly, this indicator will appear. If no blue color is visible in the Test Complete window after 10 minutes, the test result is invalid. Internal Negative Procedural Control: A clear background in the Read Result window is also considered an internal negative procedural control. If the test has been performed correctly and the Reaction Unit is working properly, the background will clear to give a discernible result. Procedural Notes 1. DO NOT open the foil pouch until you are ready to perform the test. 2. Several tests may be run at one time. Catalog Number: 20121 (20-Test kit) Page 6 of 16

3. To avoid cross-contamination, use a new disposable Sample Pipette for each sample. 4. To avoid contamination, do not touch the tip of the Developer bottle to the Reaction Unit. 5. Commercial controls other than Quidel s should not be used with QuickVue+ Infectious Mononucleosis test because they may contain additives which will interfere with the test performance. TEST PROCEDURE - SERUM, PLASMA, WHOLE BLOOD Read all of the procedural instructions before running patient samples. Remove the Reaction Unit from the pouch and place it on a well-lit and level surface. The Read Result window contains a horizontal blue line pre-printed on the membrane. Catalog Number: 20121 (20-Test kit) Page 7 of 16

Hanging Drop Procedure Add two (2) hanging drops of fingertip blood directly to the center of the Add Well. Capillary Tube Procedure For fingertip blood, fill the capillary tube (50 µl) to line. Dispense all blood into the Add well. Venipuncture, Serum or Plasma Procedure For serum, plasma or whole blood samples in tubes, use the sample pipette provided. Place one drop of sample in the Add well. When adding drops, hold the Developer bottle vertically so that a Complete drop forms. Add 5 drops of Developer to the Add well. Read test result when ANY blue color appears in the Test Complete window (approximately 5 minutes). Do not read test result after 10 minutes. Refer to Interpretation of Results section for further information. Catalog Number: 20121 (20-Test kit) Page 8 of 16

INTERPRETATION OF RESULTS FOR PATIENT SAMPLES, POSITIVE AND NEGATIVE CONTROLS Positive Result: Any shade of a blue vertical line forming a (+) sign in the Read Result window along with the blue Test Complete line, is a positive result. Even a faint blue vertical line should be reported as a positive. Negative Result: No blue vertical line in the Read Result window along with the blue Test Complete line, is a negative result. Invalid Result: Test result is invalid if after 10 minutes no blue color is observed in the Test Complete window. An invalid result indicates either the test was not performed correctly or the reagents are not working properly. Should an invalid result occur, re-test the sample using a new Reaction Unit. If the problem continues, contact Technical Support toll-free in the U.S. at (800) 874-1517. Outside the USA, contact your local representative. Catalog Number: 20121 (20-Test kit) Page 9 of 16

LIMITATIONS 1. As is the case of any other diagnostic procedure, the results obtained by this kit yield data that must be used in addition to other information available to the physician. 2. QuickVue+ Infectious Mononucleosis test is a qualitative test for the detection of IM heterophile antibodies. 3. A negative result may be obtained from patients at the onset of the disease due to antibody concentration below the sensitivity of this test kit. If symptoms persist or increase in intensity, the test should be repeated. 4. Some segments of the population who contract Infectious Mononucleosis do not produce measurable levels of heterophile antibodies. Approximately 50% of children under 4 years of age who have IM may test as IM heterophile antibody negative. 4 PERFORMANCE CHARACTERISTICS QuickVue+ Infectious Mononucleosis test was compared to two other commercially available test kits: an EIA, and a slide hemagglutination test. The results obtained using QuickVue+ Infectious Mononucleosis test were substantially equivalent to the results obtained using these other tests and are summarized below. Table 1: In this study, a total of 511 serum, plasma and whole blood samples were tested using QuickVue+ Infectious Mononucleosis test and a commercially available EIA. EIA Positive EIA Negative QuickVue+ IM Positive 74 1 QuickVue+ IM Negative 0 436 Total 74 437 Of the 511 samples, 74 were found to be positive by EIA and also positive by the QuickVue+ Infectious Mononucleosis test; similarly, 437 were found to be negative by EIA and 436 were also negative by the QuickVue+ Infectious Mononucleosis test. Based on this data, specificity was 99.8% (436/437), and sensitivity was >99.9% (74/74). Overall agreement was 99.8% (510/511). Catalog Number: 20121 (20-Test kit) Page 10 of 16

Table 2: In this study, a total of 511 serum, plasma and whole blood samples were tested using QuickVue+ Infectious Mononucleosis test and a commercially available slide hemagglutination test. Slide Positive Slide Negative QuickVue+ IM Positive 74 1 QuickVue+ IM Negative 1 435 Total 75 436 Of the 511 samples, 75 were found to be positive by the slide hemagglutination test and 74 were also positive by the QuickVue+ Infectious Mononucleosis test; similarly, 436 were found to be negative by the slide hemagglutination test and 435 were also negative by the QuickVue+ Infectious Mononucleosis test. Based on this data, specificity was 99.8% (435/436), and sensitivity was 98.7% (74/75). Overall agreement was 99.6% (509/511). ASSISTANCE If you have any questions regarding the use of this product, please call Quidel's Technical Support Number (800) 874-1517 (toll-free in the U.S.A.) or (858) 552-1100, Monday through Friday, between 7:00 a.m. and 5:00 p.m., Pacific Time, U.S.A. If outside the United States, contact your local distributor or technicalsupport@quidel.com. REFERENCES 1. Henle G., Henle W. and Diehl V. (1968) Proc. Nat. Acad. Sci. USA, 59:94-101. 2. Niederman J.C., McCollum R.W., Henle G. and Henle W. (1968) J.A.M.A. 203:139-143. 3. Glade P.S. (1973) Proceedings of Symposium of Infectious Mononucleosis, Philadelphia. J.B. Lippincott Co., pp. 1-19. 4. Fleisher G.R. (1984) In Belshe R.B. (ed.): Textbook of Human Virology. Littleton, Mass., PSG Publishing Co., pp. 853-886. 5. Schooley R.T. (1987) In Braunwald E. et al. (eds): Harrison s Principles of Internal Medicine, 11th ed. New York, McGraw-Hill Inc., pp. 699-703. 6. Paul J.R. and Bunnell W.W. (1932) Amer. J. Med. Sci. 183:90-104. 7. Davidsohn I. (1937) J.A.M.A. 108:289-296. Catalog Number: 20121 (20-Test kit) Page 11 of 16

8. http://www.cdc.gov/ncidod/diseases/ebv.htm, accesed on April 27, 2010. 9. Evans A.S., Niederman J.C., Canabre L.C., West B. and Richards V.A. (1975) J. Infect. Dis. 132:546-554. 10. Bailey G.H. and Raffel S. (1935) J. Clin. Invest. 14:842-853. 11. Fletcher M.A. and Woolfolk B.J. (1971) J. Immunol. 107:842-853. 12. Biosafety in Microbiological and Biomedical Laboratories, 5 th Edition. U.S. Department of Health and Human Services, CDC, NIH, Washington, DC (2007). Covered by U.S. Patent No. 5,763,262. 20121 QuickVue+ Infectious Mononucleosis 20 Test Kit MDSS GmbH Schiffgraben 41 30175 Hannover, Germany Quidel Corporation Worldwide Headquarters 10165 McKellar Court San Diego, CA 92121 USA www.quidel.com Catalog Number: 20121 (20-Test kit) Page 12 of 16

1179900 (05/10) Catalog Number: 20121 (20-Test kit) Page 13 of 16

LOG SHEET LOG SHEET Record Built-in Procedural Controls on the first patient tested each day. Date Patient Name Negative Procedural Control (Clear Bkgd) Positive Procedural Control (Blue Line) Test Results At 5 minutes Lot Number and Exp. Date Technician 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Catalog Number: 20121 (20-Test kit) Page 14 of 16

LOG SHEET Need to run external Positive and Negative controls once for each untrained operator, once for each new shipment of kits provided that each different lot received in the shipment is tested and as deemed additionally necessary by your internal quality control procedures, and in accordance with local, state, and federal regulations or accreditation requirements. Date/Date Received 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 OG External Positive Control External Negative Control Lot Number and Exp. Date Technician Catalog Number: 20121 (20-Test kit) Page 15 of 16

LOG SHEET Need to run external Positive and Negative controls once for each untrained operator, once for each new shipment of kits provided that each different lot received in the shipment is tested and as deemed additionally necessary by your internal quality control procedures, and in accordance with local, state, and federal regulations or accreditation requirements. Date/Date Received 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 External Positive Control External Negative Control Lot Number and Exp. Date Technician 0043RA0102D-5 (07/10) Catalog Number: 20121 (20-Test kit) Page 16 of 16