Detection of carotid plaque neovascularization with Superb Micro-Vascular Imaging

Similar documents
Seeing the Unseen Clinical advances and future directions of SMI

Seeing the Unseen Clinical advances and future directions of SMI

OCT. molecular imaging J Jpn Coll Angiol, 2008, 48: molecular imaging MRI positron-emission tomography PET IMT

Vulnerable Plaque Pathophysiology, Detection, and Intervention. VP: A Local Problem or Systemic Disease. Erling Falk, Denmark

MR Imaging of Atherosclerotic Plaques

Coronary Artery Thermography

Contemporary Carotid Imaging and Approach to Treatment: Course Notes Thursday, June 22, 2017 David M. Pelz, MD, FRCPC

CLINICAL APPLICATIONS OF OPTICAL COHERENCE TOMOGRAPHY. Konstantina P. Bouki, FESC 2 nd Department of Cardiology General Hospital Of Nikea, Pireaus

Imaging Atheroma The quest for the Vulnerable Plaque

Carotid Ultrasound: Improving Ultrasound

Non-invasive Imaging of Carotid Artery Atherosclerosis

GLOBAL INNOVATION BY DESIGN

High-risk vulnerable plaques. Kostis Raisakis G.Gennimatas General Hospital of Athens

Pathology of Coronary Artery Disease

Carotid Artery Disease and What s Pertinent JOSEPH A PAULISIN DO

Added Value of Invasive Coronary Imaging for Plaque Rupture and Erosion

Evolution of diagnostic ultrasound systems Current achievements in breast ultrasound

Evolution and Revolution of System Architecture with New Generation Technology

Report For Center Created Gender D.O.B Page 1 Sean Breen HeartSmart IMT plus 3/29/2012 Male 11/26/1973 B C D E

Case Report 1. CTA head. (c) Tele3D Advantage, LLC

Assessment of plaque morphology by OCT in patients with ACS

Morphological duplex ultrasound criteria how to assess and report echolucency, inhomogeneity and ulceration

Modern liver imaging techniques - A new era in liver ultrasound

March 12th, 2018, Orlando FL. The American College of Cardiology 67 th Annual Scientific Meeting

Plaque Imaging: What It Can Tell Us. Kenneth Snyder, MD, PhD L Nelson Hopkins MD FACS Elad Levy MD MBA FAHA FACS Adnan Siddiqui MD PhD

Carotid Imaging IT S ABOUT MORE THAN JUST OBTAINING THE IMAGES

Vascular disease. Structural evaluation of vascular disease. Goo-Yeong Cho, MD, PhD Seoul National University Bundang Hospital

Technological advancements improve the sensitivity of CEUS diagnostics

Carotid Endarterectomy for Symptomatic Complete Occlusion of the Internal Carotid Artery

Cardiac CT Angiography

Pre-and Post Procedure Non-Invasive Evaluation of the Patient with Carotid Disease

Beyond Stenosis Severity: Top 5 Important Duplex Characteristics to Identify in a Patient with Carotid Disease

Gary S. Mintz,, MD. IVUS Observations in Acute (vs Chronic) Coronary Artery Disease: Structure vs Function

Invasive Coronary Imaging Modalities for Vulnerable Plaque Detection

Carotid Abnormalities Coils, Kinks and Tortuosity David Lorelli M.D., RVT, FACS Michigan Vascular Association Conference Saturday, October 20, 2012

Intuitive. Intelligent. Innovative. General Imaging

State of the Art. Advances in Cardiovascular Imaging. ESC Congres Stockholm September 1, 2010 Frank E. Rademakers, MD, PhD, FESC

Animesh Rathore, MD 4/21/17. Penetrating atherosclerotic ulcers of aorta

Evaluation of Carotid Vessels and Vertebral Artery in Stroke Patients with Color Doppler Ultrasound and MR Angiography

Diagnosis of Middle Cerebral Artery Occlusion with Transcranial Color-Coded Real-Time Sonography

NON-ATHEROSCLEROTIC PATHOLOGY OF THE CAROTID ARTERIES

Carotid Imaging. Dr Andrew Farrall. Consultant Neuroradiologist

MRI of carotid atherosclerotid plaques

Intuitive. Intelligent. Innovative. General Imaging

Frequency of Carotid Artery Stenosis in Ischemic Stroke Umair Ahmed, Aamir Shaukat, Asim Shaukat, Hooria Aamir, Awais Ahmed

Left main coronary artery (LMCA): The proximal segment

Κλινική Χρήση IVUS και OCT PERIKLIS A. DAVLOUROS ASSOCIATE PROFESSOR OF CARDIOLOGY INVASIVE CARDIOLOGY & CONGENITAL HEART DISEASE

VFI Technology to Change the Way You Work

Blood Vessels. Dr. Nabila Hamdi MD, PhD

Ultrasound Imaging of The Posterior Circulation

CT Imaging of Atherosclerotic Plaque. William Stanford MD Professor-Emeritus Radiology University of Iowa College of Medicine Iowa City, IA

FFR CT : Beyond FFR. Bon-Kwon Koo, MD, PhD. Seoul National University Hospital, Seoul, Korea. Seoul National University Hospital Cardiovascular Center

Clinical Image Gallery Next Generation Volume 1

Approach to the Patient with (suspected) Arterial Insufficiency Related Ulceration

Alessandro Della Puppa

Evaluation of Intermediate Coronary lesions: Can You Handle the Pressure? Jeffrey A Southard, MD May 4, 2013

Contents 1 Computational Haemodynamics An Introduction 2 The Human Cardiovascular System

The association of the total cardiovascular risk and non-invasive markers of atherosclerosis with the extent of coronary artery disease

Protokollanhang zur SPACE-2-Studie Neurology Quality Standards

Guide to Small Animal Vascular Imaging using the Vevo 770 Micro-Ultrasound System

Chapter 43 Noninvasive Coronary Plaque Imaging

Functional Orthopedic Imaging Capturing Motion, Flow and Perfusion. Case Study Brochure Centre University Hospital Nancy.

CARDIAC IMAGING FOR SUBCLINICAL CAD

Noninvasive Coronary Imaging: Plaque Imaging by MDCT

PoS(FISBH2006)019. Imaging Vulnerable Plaque A radionuclide approach. H. William Strauss, M.D. 1

Although plaque morphology of patients with

Contrast-Enhanced Ultrasound Imaging of Intraplaque Neovascularization in Carotid Arteries

Observe the effects of atherosclerosis on the coronary artery lumen

GUNDERSEN/LUTHERAN ULTRASOUND DEPARTMENT POLICY AND PROCEDURE MANUAL

Optimal testing for coronary artery disease in symptomatic and asymptomatic patients

Fig MHz cm/s. Table 1 Fig. 2. Fig. 3, 4. Fig. 5

Carotid Stenting and Surgery in 2016 in Russia

Culprit Lesion Remodeling and Long-term (> 5years) Prognosis in Patients with Acute Coronary Syndrome

Acute Aortic Syndromes

IVUS Analysis. Myeong-Ki. Hong, MD, PhD. Cardiac Center, Asan Medical Center University of Ulsan College of Medicine, Seoul, Korea

Arterial Wall Imaging in Symptomatic Carotid Stenosis: Delayed Enhancement on MDCT Angiography

Carotid Artery Stenting (CAS) Pathophysiology. Technical Considerations. Plaque characteristics: relevant concepts. CAS and CEA

Lung Perfusion Analysis New Pathways in Lung Imaging. Case Study Brochure PLA 309 Hospital

FFR and outcome: The mechanistic link

Case 37 Clinical Presentation

Superb microvascular imaging (SMI) compared with conventional ultrasound for evaluating thyroid nodules

2yrs 2-6yrs >6yrs BMS 0% 22% 42% DES 29% 41% Nakazawa et al. J Am Coll Cardiol 2011;57:

actually rupture! Challenges to the vulnerable plaque concept

Carotid Artery Stenting

Making the difference with Live Image Guidance

Coronary Artery Calcification

Carotid Stenosis (carotid artery disease)

Fibromuscular Dysplasia (FMD) of the renal arteries Angiographic features and therapeutic options

Ambiguity in Detection of Necrosis in IVUS Plaque Characterization Algorithms and SDH as Alternative Solution

The Case for Intravenous EDTA Chelation Therapy, August, 2006 update.

CARDIOLOGY GRAND ROUNDS

Spontaneous embolisation on TCD and carotid plaque features

Cardiovascular Research Foundation and Columbia University Medical Center, New York.

Contrast-Enhanced Ultrasound for Assessing Carotid Atherosclerotic Plaque Lesions

TO CATCH A THIEF: IMAGING OF SUBCLAVIAN STEAL

How to evaluate heart disease - Do we need new tools Focus on myocardial circulation

Pediatric Lung Ultrasound (PLUS) In Diagnosis of Community Acquired Pneumonia (CAP)

(Department of Radiology, Beylikdüzü State Hospital, İstanbul, Turkey) Corresponding Author: Dr. Mete Özdikici

Vascular Ultrasound: Current state, current needs, future directions

CASE from South Korea

Transcription:

Detection of carotid plaque neovascularization with Superb Micro-Vascular Imaging Yong Qiang Professor Ultrasonic Department, Beijing An-Zhen Hospital, Capital Medical University, China

1. Background Conventional color Doppler ultrasound imaging is a radiation free, non-invasive technique for visualizing carotid arterial structures and hemodynamics, therefore it is regarded as one of the preferred tools for diagnosing carotid artery disease. A motion wall filter is applied when using Doppler imaging techniques to remove artefacts and clutter, however, during this process, the low-velocity blood flow signal may also be removed, causing a loss of the low blood flow signal. Therefore the limitation for conventional Doppler imaging to detect micro vascularity e.g. in the evaluation of intra-plaque neovascularization is highly challenging. Superb Micro-Vascular Imaging (SMI) is an innovative, unique Doppler technology created by Toshiba to overcome limitations of the conventional Doppler technique. SMI employs an exclusive algorithm to distinguish true low-velocity flow from clutter. As a result, SMI allows the visualization of minute vessels with low velocity flow signals without the use of contrast agents. There are two modes in SMI: monochrome (msmi) and color (csmi). Monochrome SMI provides unparalleled sensitivity, by subtracting background information, allowing users to focus on the vasculature and as a result is useful for detecting minute vessels originating in intra-plaque neovascularization. Early detection of neovascularization within atherosclerotic plaque as an indicator in assessing the stability of vulnerable plaque, will assist in the planning of interventional treatment 1-3. a result of the size of the atheromatous plaque, but its rupture due to instability. Plaque instability can be caused by neovascularization through the intussusceptive angiogenesis from adventitial vasa vasorum 1-3. Neovascularization originates from vascular tunnels formed by endothelial cells. As they lack the support from connective tissue and basement membrane, the blood vessels becomes fragile and have a high tendency for vessel rupture and hemorrhage. Neovascularization may promote rapid growth of plaque, and even induce intra-plaque hemorrhage and plaque rupture, causing ischemic strokes. Histopathological evidence shows that vulnerable plaque has twice the neovascularization of stable plaque. With the neovacsularization density in ruptured plaque being four times that of stable plaque. Neovascularization is frequently located in the fibrous cap, lipid rich regions or areas of active inflammation 4. Previous studies have shown that conventional color Doppler and power Doppler imaging techniques have limitations in visualizing plaque neovascularization. Contrast-enhanced ultrasound imaging (CEUS) is recognized No. Cases 30 25 20 15 10 as the gold standard in the detection of carotid plaque neovascularization. CEUS couples contrast specific imaging techniques with ultrasound microbubble contrast agents to better differentiate contrast signals within vessels and the surrounding tissue. CEUS visualization of intra-plaque neovascularization in carotid arteries has good correlation with histological scores. However, there are drawbacks with CEUS, in particular there are restrictions to access in some areas of the world and it places an additional cost burden on the patient. Without the use of contrast media and utilizing SMI technology we could detect micro vessel flow from 39 plaques in 32 patients with symptomatic carotid artery stenosis (percent diameter stenosis <50%) with msmi. The plaque included 25 hypoechoic plaque and 14 were mixed. Table 1 shows the distribution of neovascularization inside the plaque. In this study, the neovacsularization location and vasculature detected by SMI correlates well with the CEUS Kappa value of 0.72. The result shows that SMI is a highly reliable method for observing carotid plaque neovascularization. 2. The advantage of SMI in carotid plaque neovascularization Approximately 30% of strokes are caused by atherosclerotic plaque 4. The main reason for stroke in this clinical situation is not the stenosis caused as 5 0 Cap Proximal end of the shoulder Distal end of the shoulder Base Table 1. SMI imaging for distribution of neovascularization inside the plaque 2

[Case 1] 67M Background The patient presented with high blood pressure and vertigo. B-mode demonstrated a predominantly hypoechoic mixed plaque measuring 0.5 cm 2.8 cm and situated on the anterior wall of the left common carotid artery bifurcation. Intra-plaque neovascularization was detected with SMI. A microvessel located between the cap and the center of plaque can be visualized. Using carotid CEUS, contrast agent perfused into the plaque through the cap proving conclusive correlation between SMI and CEUS. Figure 1. B-mode image of plaque located at LCCA A predominantly hypoechoic mixed plaque is detected along the anterior wall at the left common carotid artery bifurcation. Figure 2. SMI image of plaque located at LCCA SMI clearly detected micro vessels located between the cap and the center of the plaque. 1. CEUS 2. MFI Figure 3. CEUS image of plaque located at LCCA Enhancement can be seen within the plaque. Contrast agents perfused into the plaque through the cap. Micro Flow Imaging (MFI) increased the consistency of detection. 3

[Case 2] 54M Background This patient presented with bilateral leg edema. B-mode images detected a hypoechoic plaque along the anterior wall in the middle right common carotid artery, measuring 0.23 cm 3.0 cm. SMI demonstrated micro vascularity situated at the distal shoulder of the plaque and extending from the adventitia. CEUS confirmed these results with enhancement demonstrated at the distal shoulder of the plaque extending from the adventitia into the plaque. Figure 4. SMI image of hypoechoic plaque situated at the anterior wall of the right common carotid artery SMI clearly detected micro flow inside the hypoechoic plaque. Figure 5. CEUS image of hypoechoic plaque situated at the anterior wall of the right common carotid artery Contrast enhancement was demonstrated within the hypoechoic plaque, with microflow at the distal shoulder of the plaque extending from the adventitia into the plaque. 4

[Case 3] 58M Background A patient with Ischemic Cerebrovascular disease and type 2 diabetes was diagnosed with a hypoechoic plaque measuring 0.37 cm 3.1 cm, situated at the anterior wall of the right carotid bifurcation. SMI detected irregular perfusion within the plaque (Figure 6). This finding was confirmed with CEUS, demonstrating intra-plaque neovascularization. Figure 6. SMI image of hypoechoic plaque situated at the anterior wall of the right common carotid bifurcation SMI detected irregular perfusion within the hypoechoic plaque situated on the anterior wall of the right common carotid artery Figure 7. CEUS image of hypoechoic plaque situated at the anterior wall of the right carotid bifurcation CEUS demonstrated irregular perfusion from within the hypoechoic plaque at the anterior wall of right carotid bifurcation 5

[Case 4] 59F Background Routine ultrasound screening of a patient suffering from vertigo demonstrated hypoechoic plaque measuring 0.4 cm 3.5 cm situated on the posterior wall of the left carotid bifurcation. SMI demonstrated neovascularization with multiple branches within the plaque (Figure 8). Carotid CEUS confirmed the above findings. Figure 8. SMI image of hypoechoic plaque situated at the posterior wall of the left carotid bifurcation SMI detected a branch like pattern within the hypoechoic plaque at the posterior wall of the left carotid bifurcation. Figure 9. CEUS image of hypoechoic plaque situated at the posterior wall of the left carotid bifurcation CEUS detected a branch like pattern within the hypoechoic plaque situated at the posterior wall of the left carotid bifurcation. 6

3. Future work In majority of the cases, SMI demonstrated neovascularization that was confirmed by CEUS. In a small percentage for hypoechoic or predominantly mixed plaque where no neovacsularization was detected by SMI, CEUS examinations will be conducted. SMI and CEUS outcomes will be analyzed within the criteria of statistical calculation of sensitivity, specificity and accuracy to enable causes for significant variations between SMI and CEUS results to be investigated. Quantitative analysis for carotid plaque neovacsularization is required to enable appropriate drug therapy to be given. Further development of SMI and its uses, to facilitate a quantitative measurement, has great potential for the future. 4. Conclusion SMI offers the ability to detect carotid plaque neovascularization without the use of CEUS. As a result, SMI may become a powerful tool for evaluating vulnerable carotid plaque. Reference 1. L. Xiong, Y.B. Deng,Y.Zhu, et al. Correlation of carotid plaque neovascularization detected by using contrastenhanced US with clinical symptoms. Radiology. 2009 May; 251(2):583-9. 2. M.Naghavi, P. Libby, E. Falk, et al. From vulnerable plaque to vulnerable patient: a call for new definitions and risk assessment strategies: Part I. Circulation. 2003 Oct; 108(14):1664-72. 3. JO. Juan-Babot, J. Martínez-Gonzále, M. Berrozpe, et al. Neovascularization in human coronary arteries with lesions of different severity. Rev Esp Cardiol. 2003 Oct; 56(10):978-86. 4. PR. Moreno, KR. Purushothaman, V. Fuster, et al. Plaque neovascularization is increased in ruptured atherosclerotic lesions of human aorta: implications for plaque vulnerability. Circulation. 2004 Oct 5; 110(14):2032-8. Epub 2004 Sep 27. Additional reading 1. Terminology and Diagnostic Criteria Committee, Japan Society of Ultrasonics in Medicine. Standard method for ultrasound evaluation of carotid artery lesions. J Med Ultrasonics 2009 Dec; 36(4): 219-226. 2. S Feinstein. Contrast Ultrasound Imaging of the Carotid Artery Vasa Vasorum and Atherosclerotic Plaque Neovascularization. J Am Coll Cardiol. 2006 Jul 18; 48(2):236-43. Epub 2006 Jun 22. 3. B. Doyle, N. Caplice. Plaque Neovascularization and Antiangiogenic Therapy for Atherosclerosis. J Am Coll Cardiol. 2007 May; 49(21):2073-80 Comment from reviewer The existence of blood flow in plaque is known to be important for evaluating the characteristics of the plaque. With the introduction of SMI, observation of blood flow in plaque could be observed without the use of CEUS. It is clear that SMI is a method that is free of contrast medium, easy-to-use and inexpensive for observing blood flow in plaque. Henceforth, the study of relationship between characteristics and blood flow in plaque that has been difficult to observe is expected to have an additional contrast free process. Hiroshi Matsuo, M.D. Matsuo Cardiovascular Clinic Osaka, Japan 7

http://www.toshibamedicalsystems.com Toshiba Medical Systems Corporation 2015. All rights reserved. Design and specifications subject to change without notice. MOIUS0076EA 2015-03 TMSC/D Toshiba Medical Systems Corporation meets internationally recognized standards for Quality Management System ISO 9001, ISO 13485. Toshiba Medical Systems Corporation Nasu Operations meets the Environmental Management System standard ISO 14001. Printed in Japan