QUARTERLY REPORT PATIENT SAFETY WORK PRODUCT Q J A N UA RY 1, 2016 MA R C H 31, 2016

Similar documents
Medical Errors in Radiation Therapy 2014

The Canadian National System for Incident Reporting in Radiation Treatment (NSIR-RT) Taxonomy March 11, 2015

Medical Events. Florida Department of Health Division of Emergency Preparedness and Community Support Bureau of Radiation Control

National System for Incident Reporting in Radiation Therapy (NSIR-RT) Taxonomy

Risk-based QM for Incorrect Isocenter at Day 1 Setup. TG 100 risk based QM development Process Mapping

The Smart Way to Check Treatment Plans and Charts. Anne W. Greener, Ph.D., FACR American Association Of Medical Dosimetrists June 15, 2016

Risk analysis to inform physics plan review recommendations

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

Completion of Treatment Planning. Eugene Lief, Ph.D. Christ Hospital Jersey City, New Jersey USA

NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

ADVANCED TECHNOLOGY CONSORTIUM (ATC) CREDENTIALING PROCEDURES FOR LUNG BRACHYTHERAPY IMPLANT PROTOCOLS

Using Event Reporting to Improve Patient Safety SAMs Session

The University of Michigan Radiation Oncology Clinic Analysis of Waste in the Radiation Oncology Clinic Patient Flow Process.

Varian Acuity BrachyTherapy Suite One Room Integrated Image-Guided Brachytherapy

Standards for Radiation Oncology

Importance of daily portal imaging for Head and Neck IMRT treatments. Luciant Wolfsberger Brigham & Women s Hospital

Who Should Know Radiation Oncology Coding?

Understanding Radiation Therapy. For Patients and the Public

19 CP Add teaching file export related codes

Are Transmission Detectors a Necessary Tool for a Safe Patient Radiation Therapy Program?

Quality management for Breast Brachytherapy.

19 CP Add teaching file export related codes

Reporting of Errors. Linda Harvey Quality Manager UCLH 28 th September 2012

EORTC Member Facility Questionnaire

Brachytherapy Planning and Quality Assurance w Classical implant systems and modern computerized dosimetry w Most common clinical applications w

Brachytherapy Planning and Quality Assurance

RO-ILS: Radiation Oncology Incident Learning System Congressional Briefing

Public Comment Period for Proposed Radiation Oncology Survivorship Care Plan Template

7/10/2015. Acknowledgments. Institution-specific TG-142? AAPM:Task Group-142. Failure-Mode & Effects Analysis

SUPERIORITY OF A REAL TIME PLANNING TECHNIQUE OVER IMAGE GUIDED RADIATION THERAPY FOR THE TREATMENT OF PRIMARY PROSTATE CANCERS

8/2/2018. Disclosure. Online MR-IG-ART Dosimetry and Dose Accumulation

IMRT/IGRT Patient Treatment: A Community Hospital Experience. Charles M. Able, Assistant Professor

Intensity modulated radiotherapy (IMRT) for treatment of post-operative high grade glioma in the right parietal region of brain

Clinical Implementation of a New Ultrasound Guidance System. Vikren Sarkar Bill Salter Martin Szegedi

Report on Radiation Disaster Recovery Studies

MEDICAL PHYSICS IN SUPPORT OF CANCER MANAGEMENT: HUMAN RESOURCE DEVELOPMENT IN RADIATION ONCOLOGY IN THE CONTEXT OF CANCER CONTROL PROGRAMMES

CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT

Clinical Quality Assurance for Particle Therapy Plus ça même Plus

Variable Dose Rate Dynamic Conformal Arc Therapy (DCAT) for SABR Lung: From static fields to dynamic arcs using Monaco 5.10

Goals and Objectives: Head and Neck Cancer Service Department of Radiation Oncology

Interstitial Breast Brachytherapy

Radiation Safety in IGRT Cases, Causes and Culture of Safety

Brachytherapy. What is brachytherapy and how is it used?

3D CONFORMATIONAL INTERSTITIAL BRACHYTHERAPY PLANNING FOR SOFT TISSUE SARCOMA

Patient-Specific QA & QA Process. Sasa Mutic, Ph.D. Washington University School of Medicine

RTOG DOSIMETRY DATA SUBMISSION

Patient Safety in the Age of Big Data

Coding Updates for Dosimetry Services

Overview of TG225 - Medical Physics Practice Guideline #1

Automated Plan Quality Check with Scripting. Rajesh Gutti, Ph.D. Clinical Medical Physicist

Think Critically. Dimension Assessed * COURSE Course OUTCOMES ASSIGNMENTS/ASSESSMENTS

FEE RULES RADIATION ONCOLOGY FEE SCHEDULE CONTENTS

Lessons learned from accidents in conventional external radiotherapy

Global Radiosurgery 2011 All Rights Reserved 1

Quality Assurance in Radiation Therapy

Radiotherapy physics & Equipments

Panel consensus was not to include suggested revision.

Analysis on the Reporting of Medical Events in Permanent Prostate Brachytherapy

QA for Clinical Dosimetry with Emphasis on Clinical Trials

Varian Treatment. Streamlined Treatment Delivery Management Application. Specifications

Breast Conservation Therapy

Radiation Oncologists and Cancer Treatment Facilities Quick Reference Guide

Cancer Awareness & Early Diagnosis Project Examples. Location: Camden (intervention area) and Kensington & Chelsea (control area), London

Partial Breast Irradiation using adaptive MRgRT

LA GESTIONE DELLE NUOVE TECNOLOGIE Cinzia Iotti. Azienda Arcispedale S. Maria Nuova IRCCS Reggio Emilia

MOTION MANAGEMENT & PATIENT SAFETY REDEFINED!

Major accidents in radiotherapy

Presentation Outline. Patient Setup Imaging in RT: Getting the Most Bang for your Buck. Main Errors in RT. Hypothetical Patient Examples

Gaps In Successful EHR Implementations: The Challenges & Successes Of Providers In The Marketplace

Therapy symposium Formal Radiation Therapy Safety Processes

Comparison of high and low energy treatment plans by evaluating the dose on the surrounding normal structures in conventional radiotherapy

Normal tissue doses from MV image-guided radiation therapy (IGRT) using orthogonal MV and MV-CBCT

Provisional Accreditation

Polypharmacy and Deprescribing. A special report on views from the PrescQIPP landscape review

IGRT Protocol Design and Informed Margins. Conflict of Interest. Outline 7/7/2017. DJ Vile, PhD. I have no conflict of interest to disclose

A method to predict patient specific table coordinates for quality assurance in external beam radiation therapy

Patterns of Care in Patients with Cervical Cancer:

Can we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer?

Medical Dosimetry Graduate Certificate Program IU Graduate School & The Department of Radiation Oncology IU Simon Cancer Center

Education and Training Committee 15 November 2012

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014

A Patient s Guide to SRS

Medical Physicists Bring New Value to Patient-Centered Care

Accurate Accurate boost or Simply Accuboost

Leila E. A. Nichol Royal Surrey County Hospital

Dental ConeBeam Computed Tomography (CBCT) X-ray Systems

Patient & Family Guide. Radiation Therapy.

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

CODING GUIDELINES. Radiation Therapy. Effective January 1, 2019

Report to: Public Board of Directors Agenda item: 11 Date of Meeting: 25 July Gosport Hospital Report & RUH Assurance

Head and Neck Service

How ICD-10 Affects Radiation Oncology. Presented by, Lashelle Bolton CPC, COC, CPC-I, CPMA

Failure Mode and Effects Analysis (FMEA) Margaret Colquhoun

NEWS A Publication of Vantage Oncology, Tri-State Radiation Oncology Centers - TROC

Spatially Fractionated Radiation Therapy: GRID Sponsored by.decimal Friday, August 22, Pamela Myers, Ph.D.

SunCHECK Patient Comprehensive Patient QA

This chapter shows how to use a formula method for dosage calculation to calculate the

Cervical Cancer Treatment

Transcription:

QUARTERLY REPORT PATIENT SAFETY WORK PRODUCT Q1 2016 J A N UA RY 1, 2016 MA R C H 31, 2016 CLARITY PSO, a Division of Clarity Group, Inc. 8725 West Higgins Road Suite 810 Chicago, IL 60631 T: 773.864.8280 F: 773.864.8281 www.claritypso.com CLARITY PSO 2016 ALL RIGHTS RESERVED

TABLE OF CONTENTS Aggregate Report Card...2 Analysis and Commentary...3-9 Introduction...3 Featured Themes...3 HDR with Equipment for Different Vendors...3 Laterality Errors...4 Manual Data Entry...4 Patient Orientation...5 Approved Plan Different from Intent...5-6 Data Analysis: Occurrence and Discovery of Errors...6-9 within the Workflow Process Aggregate Analysis Graphs....10-18 CLARITY PSO 2016 ALL RIGHTS RESERVED. 1

AGGREGATE REPORT CARD Q1 2016 January 1, 2016 March 31, 2016 METRIC AGGREGATE CURRENT QUARTER AGGREGATE PREVIOUS QUARTER AGGREGATE HISTORICAL SUM Total Number of Events Patient Incident Near Miss Unsafe Conditions 297 110 95 92 289 104 102 83 1632 589 555 488 Most Commonly Identified Characterization of Event Not Sure How to Characterize: 29% (86/297) Unanswered/Not Sure: 37% (111/297) Not Sure How to Characterize: 33% (95/289) Unanswered/Not Sure: 39% (112/289) Not Sure How to Characterize: 26% (421/1632) Unanswered/Not Sure: 37% (598/1632) Most Commonly Identified Workflow Step Where Event Occurred Treatment Planning: 27% (80/297) Unanswered: 24% (72/297) Treatment Planning: 32% (92/289) Unanswered: 19% (55/289) Treatment Planning: 30% (494/1632) Unanswered: 24% (389/1632) Most Commonly Identified Treatment Technique 3D: 23% (67/297) Unanswered: 44% (132/297) 3D: 19% (56/289) Unanswered: 47% (135/289) 3D: 21% (343/1632) Unanswered: 48% (776/1632) Characterization of Dosimetric Severity for Events That Reached the Patient Desired Procedure Omitted: 39% (13/33) Incorrect Dose to All or Part of Body: 56% (10/18) Incorrect Dose to All or Part of Body: 37% (67/179) Potential Future Toxicity Within Events That Reached the Patient None or mild: 55% (60/110) Unanswered: 45% (49/110) None or mild: 39% (41/104) Unanswered: 58% (60/104) None or mild: 50% (296/589) Unanswered: 45% (267/589) CLARITY PSO 2016 ALL RIGHTS RESERVED. 2

ANALYSIS & COMMENTARY INTRODUCTION Within this Q1 2016 report, there are two main content sections: Featured Themes and Data Analysis. Each of these sections provides deeper analysis and case studies derived from the events submitted to the database. These events directly relate to the correlating themes discussed within each section. The shared learning from RO-ILS: Radiation Oncology Incident Learning System, which subsequently leads to safer, higher quality care, is dependent upon the submission of events by providers. The first event, within the high-dose-rate (HDR) with equipment from different vendors section, in particular, is an excellent example of a provider utilizing this program to reach out to the community and share information about an error pathway that affected patients. RO-ILS provides a safe environment for such dissemination. The events described in this report are valuable examples of the expectation set for this program. FEATURED THEMES HDR with equipment from different vendors This quarter there were two events reported that related to the positioning of HDR brachytherapy sources in a treatment applicator. In one case, there was confusion about the proper method for manually inserting a dummy marker to indicate the treatment position, leading to a geographic miss of approximately 4.6 cm for two endobronchial treatments on one patient. Subsequent investigation revealed that the same error had been made on two other patients. The problem arose because of uncertainty in how to use dummy markers in a new HDR system that had replaced one from a different vendor. The old system required that the treatment adapter be attached to the endobronchial catheter before the dummy markers were inserted, while the new system required that the treatment adapter not be attached. Deficiencies in training and vendor documentation were identified as contributing factors. The facility reported the events to the relevant regulators. In its internal analysis of the event, the facility staff highlighted the importance of involving the people who actually perform the various steps in the process in the end to end tests of new procedures. In this case, some members of the therapist and physics groups had different understandings about how to use the dummy markers. An end-to-end test performed solely by physicists would not have revealed that ambiguity. It is also worth emphasizing that the problem was identified and solved after a team member saw something that did not seem right and asked the question. In the other case, the planning system used for HDR planning applied a default value for the applicator length that is 20 cm shorter than the actual catheter, and that was not corrected during planning. The mismatch was found and corrected by a physicist before treatment. These two cases involving HDR afterloaders illustrate the importance of revealing, and if necessary correcting, assumptions that exist in our minds or in our software, and these can often be manifested when transitioning from or mixing systems from different vendors. It is of utmost importance to challenge ourselves and ask questions even when the system and process appear correct. CLARITY PSO 2016 ALL RIGHTS RESERVED. 3

ANALYSIS & COMMENTARY continued Laterality errors Additionally, there were two events this quarter of laterality errors made by physicians prescribing treatment that were recognized and corrected by technical staff before treatment. In one case the dosimetrist reviewed the medical record before beginning planning to check the laterality and in the other case the radiation therapists recognized that the wrong hip was targeted and called for a correction. These last two events demonstrate the value of having fully engaged staff who are empowered to take initiative to prevent treatment errors. Manual data entry Not surprisingly, a common feature of many events is that some information that requires manual data entry was entered incorrectly. When the error is identified and corrected at the first available quality assurance (QA) step, it indicates that the QA step is necessary and is functioning. However, it often happens that the error is not found until later in the process, and that then indicates a need to improve the QA process (or better yet change the system to remove the need for manual data entry). A frequent issue seen is that shift instructions are incorrect. In this quarter, there were six events involving shift instructions. While none of the events this quarter led to an incorrect treatment, manual entry surrounding shifts requires added attention. Case 1: In one case, a 0.3 cm shift was transcribed as 3 cm, but the discrepancy was identified by the cone beam computed tomography (CBCT) used for image guidance. Case 2: In another case, the shift direction was given as right when left was correct; this was also found early by the physics plan check. Case 3: In a cautionary near miss event, the desired isocenter for the CBCT was manually entered 5 cm off, so when the therapists imaged the patient this large shift was needed to align the images. They made the shift, and then, because this patient had 3-D conformal ports, they took portal images that revealed the error. Had the patient not had portal images, the error may have gone unnoticed. This near miss event highlights an issue pertinent to quality and safety: when there is a manual step that is critical to the process there needs to be a highly reliable QA step designed to test it. When a manual step is used to set up the image guidance reference there is the possibility for a systematic error. Relying on a plan checker to catch the mistake is not sufficient. A post-shift image, not subject to the same error mode as the original reference, is a better tool and should be considered as part of the sequence when starting treatment. These near miss events also highlight the issue of something happening that is out of the norm (e.g. a 5 cm shift on a patient indicated by CBCT). A questioning attitude is crucial in such a situation. Such issues can also sometimes be addressed at the level of policy and procedures, for example, a policy requiring a second check by an attending or other staff when there is a shift indicated that is larger than some predefined value. CLARITY PSO 2016 ALL RIGHTS RESERVED. 4

ANALYSIS & COMMENTARY continued Patient orientation Another example of manual data entry being a source of error is selection of patient orientation (e.g. feet-first supine). This can be required at multiple steps in the radiation oncology workflow: at the CT simulation, in the treatment planning system, and in the treatment guidance system. It is always manual at the time of simulation because the imaging device cannot detect the patient orientation. It can also happen at later stages, if direct digital data transfer is not available for that parameter. This quarter there was one event of a patient being treated feet-first who was entered as head-first into the image guidance system. In this case the patient was treated correctly but the left/right directions were reversed in the image labeling, meaning the image displayed had the incorrect orientation labels. There have been multiple events in other quarters related to patient orientation being entered incorrectly at the time of CT simulation. All of these particular events were identified and corrected, although in one event the patient was on the table for the first treatment which then had to be postponed. One facility reported that they have started a special time-out procedure in CT simulation whenever the patient orientation is not head-first, supine. This involves not only confirming that the labeling is correct but also that the oncologist marking the isocenter is aware of any change in left/right display. Approved plan different from intent There were three events reported this quarter in which a treatment plan was created and approved that used a different fractionation scheme than the physician actually intended. Case 4: The prescription was for five fractions, but the approved plan was for three. This was noted by the therapists after the patient was brought into the room for the first treatment. Case 5: The patient was told she would have 16 treatments, but the physician wrote the prescription for 28. After the first treatment, the patient was given her full schedule and she noted the change from her expectation. The plan was changed before the next treatment so she could be completed in 16 fractions total. Case 6: The plan was prepared and approved for a prescription of 4500 cgy (45 Gy) in 25 fractions, but the physicist checking the plan noted that the physician s intent document, created before the prescription, indicated 4500 cgy (45 Gy) in 15 fractions. The plan was revised after the patient s verification appointment had occurred, but before the first treatment. CLARITY PSO 2016 ALL RIGHTS RESERVED. 5

ANALYSIS & COMMENTARY continued This is a recurring issue that was discussed in detail in the Q4 2015 Quarterly Report. However, there is a specific failure pathway that has not yet been highlighted. In at least six cases within the database, the narrative either states or implies that the planner wrote the prescription that the physician approved, but the planner s understanding of the intent was incorrect. In one case a patient with breast cancer had her supraclavicular region targeted in error and treated twice before the case was reviewed in chart rounds and the field discontinued. In another case, the physician verbally ordered 12 in 2, intending 2 fractions of 6 Gy, but the planner assumed the intent was 6 fractions of 2 Gy. The plan was prepared and approved for 2 Gy/fraction and one treatment was delivered. This error was also discovered at chart rounds. Facilities that permit a planner to prepare the final prescription for the physician to approve may wish to consider workflows that reduce the chance for error. In those situations, and in general, a physician who verbalizes the key elements of the prescription before approving it is more likely to recognize and prevent a contradiction. This is only one suggestion and should be discussed internally. While it is well understood that one should not rely solely on verbal communication for critical matters, we should also consider the potential weakness of relying solely on written communication. A combination of both verbal and written communication engages the attention more completely. It is especially beneficial to have a standard sequence when expressing the elements of a dose prescription, as that can reduce the chance of misunderstanding. This fall, ASTRO will be publish a manuscript titled Standardizing Dose Prescription: An ASTRO White Paper to help create a consistent format for presenting the dose prescription. DATA ANALYSIS: OCCURRENCE AND DISCOVERY OF ERRORS WITHIN THE WORKFLOW PROCESS In what workflow step(s) did the event occur and in what workflow step(s) was the event discovered are both asked during the follow-up review of the event. These questions are not mandatory. The following graph demonstrates how these events (in which one or both of these data elements are answered) are distributed throughout the workflow steps. Occurrence refers to when or where an event happened. Discovery refers to when or where an event was found. Therefore, an event could (and often does) happen earlier in the process, but is not caught until later. CLARITY PSO 2016 ALL RIGHTS RESERVED. 6

ANALYSIS & COMMENTARY continued FIGURE 1. EVENT OCCURRENCE AND DISCOVERY FOR ALL EVENTS (N =1146) CLARITY PSO 2016 ALL RIGHTS RESERVED. 7

ANALYSIS & COMMENTARY continued Of the 1632 events in the database through Q1 2016, 70 percent (1146/1632) had both the data elements for occurrence and discovery filled out. It is of particular interest to look at the number of cases in which the event occurred early in the process, i.e., in Treatment Planning or earlier, but the event was not discovered until Treatment Delivery or later (i.e., early occurrence, late discovery ). These are the cases that passed through QA steps that in principle should have found the problem. Table 1 and Figure 2 highlights this subset of events. Table 1. Events that occurred during Treatment Planning or earlier and in what workflow step those events were discovered. Type Number Percent Discovered in Treatment Planning or Earlier 190 28.3% Discovered in Pre-treatment Review and Verification 285 42.4% Discovered in Treatment Delivery or Later 197 29.3% Total Occurred During Treatment Planning or Earlier 672 100% We see from this subset of data that 58.6 percent (672/1146) of events occurred early in the process, and 29.3 percent (197/672) of those were not discovered until Treatment Delivery or later. As discussed in the Q4 2015 Quarterly Report, the Radiation Oncology Healthcare Advisory Council (RO-HAC) scores events as perceived risk on a 1-5 scale, where 1 is low and 5 is critical. Of the 29.3 percent (197/672) of events that made it through the pre-treatment checks, 47.7 percent (94/197) were scored as moderate risk or higher (3-5) and 23.4 percent (46/197) were scored as severe or critical (4-5). Examine your internal events through this context. Compare where events occur and where those same events are discovered within the workflow process. This investigation will lead to insight regarding process failures and functioning fail safes. CLARITY PSO 2016 ALL RIGHTS RESERVED. 8

ANALYSIS & COMMENTARY continued FIGURE 2. EARLY OCCURRENCE, LATE DISCOVERY CLARITY PSO 2016 ALL RIGHTS RESERVED. 9

AGGREGATE ANALYSIS GRAPHS CLARITY PSO 2016 ALL RIGHTS RESERVED. 10

AGGREGATE ANALYSIS GRAPHS continued CLARITY PSO 2016 ALL RIGHTS RESERVED. 11

AGGREGATE ANALYSIS GRAPHS continued CLARITY PSO 2016 ALL RIGHTS RESERVED. 12

AGGREGATE ANALYSIS GRAPHS continued CLARITY PSO 2016 ALL RIGHTS RESERVED. 13

AGGREGATE ANALYSIS GRAPHS continued CLARITY PSO 2016 ALL RIGHTS RESERVED. 14

AGGREGATE ANALYSIS GRAPHS continued CLARITY PSO 2016 ALL RIGHTS RESERVED. 15

AGGREGATE ANALYSIS GRAPHS continued CLARITY PSO 2016 ALL RIGHTS RESERVED. 16

AGGREGATE ANALYSIS GRAPHS continued CLARITY PSO 2016 ALL RIGHTS RESERVED. 17

AGGREGATE ANALYSIS GRAPHS continued CLARITY PSO 2016 ALL RIGHTS RESERVED. 18