Serum Amyloid A ELISA

Similar documents
Apolipoprotein A-1 ELISA

Mouse C3 (Complement Factor 3) ELISA Kit

ab Hemoglobin Human ELISA Kit

EliKine Free Thyroxine (ft4) ELISA Kit

Mouse C-Peptide ELISA Kit

Human HIV (1+2) antigen&antibody ELISA Kit

Instructions for use. TSH rat ELISA. Please use only the valid version of the Instructions for Use provided with the kit AR E-8600

Human TSH ELISA Kit. User Manual

Human Thyroid-Peroxidase Antibody, TPO-Ab ELISA Kit

Morinaga Mouse C-peptide ELISA Kit

HbA1c (Human) ELISA Kit

Canine Thyroid Stimulating Hormone, TSH ELISA Kit

Rat cholesterol ELISA Kit

Influenza A IgG ELISA

Instructions for use. TSH rat ELISA. Please use only the valid version of the Instructions for Use provided with the kit AR E-8600

Bovine Insulin ELISA

Rat Insulin ELISA. For the quantitative determination of insulin in rat serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Insulin (Porcine/Canine) ELISA

IV2-113E Use by. Invitron Glargine ELISA Kit REF LOT IVD. Definitions. English. For in-vitro diagnostic use. Instructions for use.

Mouse Leptin ELISA Kit Instructions

Vedolizumab Drug Level ELISA

Prothrombin (Human) ELISA Kit

Porcine/Canine Insulin ELISA

GLP-2 (Rat) ELISA. For the quantitative determination of glucagon-like peptide 2 (GLP-2) in rat serum and plasma

Human LDL ELISA Kit. Innovative Research, Inc.

Mouse C-peptide ELISA

HBeAg and HBeAg Ab ELISA Kit

Mouse Ultrasensitive Insulin ELISA

Rat Proinsulin ELISA

APOB (Human) ELISA Kit

02006B 1 vial 02006B 1 vial Store at -20 C. Lyophilized recombinant IL-2

TECHNICAL BULLETIN. GLP-1 EIA Kit for serum, plasma, culture supernatant, and cell lysates. Catalog Number RAB0201 Storage Temperature 20 C

Fish follicle-stimulating hormone, FSH ELISA Kit

STAT1 (ps727) (Human/Mouse) ELISA Kit

Human cholesterol, CH ELISA Kit

Mouse C-peptide ELISA

STAT3 (py705)/ Pan STAT3 (Human/Mouse/Rat) ELISA Kit

GLP-2 ELISA. For the quantitative determination of GLP-2 in human serum and plasma samples.

Rat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum. For Research Use Only. Not For Use In Diagnostic Procedures.

Ultra-sensitive Human TSH ELISA Kit. MyBioSource.com

Hepatitis A virus IgM ELISA Kit

SIV p27 Antigen ELISA Catalog Number:

LDL (Human) ELISA Kit

STAT3 (py705) (Human/Mouse/Rat) ELISA Kit

RayBio Human Granzyme B ELISA Kit

Cotinine (Mouse/Rat) ELISA Kit

TECHNICAL BULLETIN. Catalog Number RAB0447 Storage Temperature 20 C

Human Mullerian Inhibiting Substance/Anti-Mullerian hormone, MIS/AMH ELISA Kit

Insulin ELISA. For the quantitative determination of insulin in serum and plasma.

TECHNICAL BULLETIN. C-Peptide EIA Kit for serum, plasma, culture supernatant, and cell lysates. Catalog Number RAB0326 Storage Temperature 20 C

TECHNICAL BULLETIN. Phospho-Akt (pser 473 ) ELISA Kit for detection of human, mouse, or rat phospho-akt (pser 473 ) in cell and tissue lysates

Rat Mullerian Inhibiting Substance/Anti-Mullerian hormone, MIS/AMH ELISA kit

ENA screen (Extractable Nuclear Antigen) ELISA

YK052 Mouse Leptin ELISA

Morinaga Mouse/Rat Leptin ELISA Kit

EGFR (py1045)/ Pan EGFR (Human) ELISA Kit

FOR LABORATORY USE ONLY

Rabbit Glycated hemoglobin A1c (GHbA1c) ELISA Kit

Rat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum

Human IL-2 ELISA Antibody Pair

SIV p27 ANTIGEN CAPTURE ASSAY

AssayMax Human Aldose Reductase ELISA Kit

Procine sphingomyelin ELISA Kit

DRG International, Inc., USA Fax: (908)

Human HBcAb IgM ELISA kit

RayBio Human ENA-78 ELISA Kit

HUMAN FERRITIN ELISA. Product Data Sheet. Cat. No.: RCAN-F-4280R. For Research Use Only. Page 1 of 16 VERSION

Free Estriol ELISA. For the quantitative determination of free estriol in serum

HIV-1 p24 ELISA Kit. Catalog Number KA assays Version: 06. Intended for research use only.

Rubella virus IgG ELISA Kit

HIV-1 p24 Antigen ELISA Catalog Number:

RayBio Human Phospho-DDR1 (Tyr792) ELISA Kit

Rat Leptin-HS ELISA FOR LABORATORY USE ONLY YANAIHARA INSTITUTE INC AWAKURA, FUJINOMIYA - SHI SHIZUOKA, JAPAN

RayBio Human Phospho-DDR2 (Tyr740) and Total DDR2 ELISA Kit

Mouse Adiponectin Immunoassay Kit

RayBio Human Phosphotyrosine BTK ELISA Kit

RayBio Human Phospho-DDR1 (Tyr792) and Total DDR1 ELISA Kit

Human Cathepsin V ELISA Kit

Mouse/Rat THYROXINE (T4) ELISA Catalog No (96 Tests)

Leptin ELISA. For the quantitative determination of Leptin in human serum. For Research use Only. Not For Use In Diagnostic Procedures.

Human Thyroglobulin EIA

This kit is intended for Research Use Only. Not for use in diagnostic procedures.

Human Free Thyroxine (ft4) CLIA Kit

TECHNICAL BULLETIN. Ghrelin EIA Kit for serum, plasma, culture supernatant, and cell lysates. Catalog Number RAB0207 Storage Temperature 20 C

Rat Leptin ELISA FOR LABORATORY USE ONLY YANAIHARA INSTITUTE INC AWAKURA, FUJINOMIYA - SHI SHIZUOKA, JAPAN

TNF-alpha ELISA. For Research Use Only. Not For Use In Diagnostic Procedures.

Hepatitis B surface antigen Ab ELISA Kit

HIV-1 p24 ELISA Kit. Cat.No: DEIA10155 Lot. No. (See product label) Size. Storage. Principle Of The Test. Reagents And Materials Provided

Triiodothyronine (T3) ELISA

Human Obestatin ELISA

RayBio Human, Mouse and Rat Phospho-NF-kB P65 (Ser536) and Total NF-kB P65 ELISA Kit

Human Thyroid Stimulating Hormone CLIA kit

For the quantitative measurement of Human Prothrombin concentrations in cell culture supernatants, milk, plasma and urine

Rat IL-2 ELISA Kit. Instructions for use. For research use only. Fast Track Your Research.

ab Human Annexin A10 ELISA Kit

RayBio Human Thyroglobulin ELISA Kit

For the quantitative determination of Glucagon concentrations in cell culture supernates, serum and plasma.

Human LDL Receptor / LDLR ELISA Pair Set

Human Aldosterone ELISA Kit

Toxoplasma gondii IgM ELISA Kit

Transcription:

Serum Amyloid A ELISA For the quantitative determination of serum amyloid A (SAA) in serum plasma For Research use Only. Not for Use in Diagnostic Procedures Please see Appendix A for Reference Serum information Catalog Number: 41-SAAHU-E01 Size: 96 Wells Version: 3 L58--10 ALPCO April 23, 2018 26-G Keewaydin Drive, Salem, NH 03079P: (800) 592-5726F: (603) 898-6854ts@alpco.comwww.alpco.com Page 1 of 6

INTENDED USE The Human Serum Amyloid A (SAA) test kits are a highly sensitive two-site enzyme-linked immunoassay (ELISA) for measuring serum amyloid A in human serum or plasma samples. PRINCIPLE OF THE ASSAY The principle of the double antibody sandwich ELISA is represented in Figure 1. In this assay the serum amyloid A present in samples reacts with the anti-serum amyloid A antibodies which have been adsorbed to the surface of polystyrene microtiter wells. After the removal of unbound proteins by washing, anti-serum amyloid A antibodies conjugated with horseradish peroxidase (HRP), are added. These enzyme-labeled antibodies form complexes with the previously bound serum amyloid A. Following another washing step, the enzyme bound to the immunosorbent is assayed by the addition of a chromogenic substrate, 3,3,5,5 -tetramethylbenzidine (TMB). The quantity of bound enzyme varies directly with the concentration of serum amyloid A in the sample tested; thus, the absorbance, at 450 nm, is a measure of the concentration of serum amyloid A in the test sample. The quantity of serum amyloid A in the test sample can be interpolated from the standard curve constructed from the standards, and corrected for sample dilution. Anti-SAA Antibodies Bound To Solid Phase Standards and Samples Added SAA*Anti-SAA Complexes Formed Unbound Sample Proteins Removed Anti-SAA-HRP Conjugate Added Anti-SAA-HRP * SAA * Anti-SAA Complexes Formed Unbound Anti-SAA-HRP Removed Chromogenic Substrate Added Determine Bound Enzyme Activity Figure 1. REAGENTS (Quantities sufficient for 96 determinations) 1. DILUENT CONCENTRATE (Assay Buffer) One bottle containing 50 ml of a 5X concentrated diluent Assay Buffer. 2. WASH SOLUTION CONCENTRATE One bottle containing 50 ml of a 20X concentrated wash solution. 3. ENZYME-ANTIBODY CONJUGATE 100X One vial containing 150 L of affinity purified anti-human serum amyloid A antibody conjugated with horseradish peroxidase in a stabilizing buffer. 4. CHROMOGEN-SUBSTRATE SOLUTION One vial containing 12 ml of 3,3,5,5 -tetramethylbenzidine (TMB) and hydrogen peroxide in citric acid buffer at ph 3.3. 5. STOP SOLUTION One vial containing 12 ml 0.3 M sulfuric acid. WARNING: Avoid contact with skin. 26-G Keewaydin Drive, Salem, NH 03079P: (800) 592-5726F: (603) 898-6854ts@alpco.comwww.alpco.com Page 2 of 6

6. ANTI-HUMAN serum amyloid A ELISA MICROPLATE Twelve removable eight (8) well microwell strips in well holder frame. Each well is coated with affinity purified anti- Human serum amyloid A. 7. HUMAN serum amyloid A CALIBRATOR One vial containing a lyophilized Human serum amyloid A calibrator. For research use only. REAGENT PREPARATION 1. DILUENT CONCENTRATE The Diluent Solution supplied is a 5X Concentrate and must be diluted 1:5 with distilled or deionized water (1 part buffer concentrate, 4 parts dh2o). 2. WASH SOLUTION CONCENTRATE The Wash Solution supplied is a 20X Concentrate and must be diluted 1:20 with distilled or deionized water (1 part buffer concentrate, 19 parts dh2o). Crystal formation in the concentrate is not uncommon when storage temperatures are low. Warming of the concentrate to 30-35 C before dilution can dissolve crystals. 3. ENZYME-ANTIBODY CONJUGATE Calculate the required amount of working conjugate solution for each microtiter plate test strip by adding 10 L Enzyme-Antibody Conjugate to 990 L of 1X Diluent for each test strip to be used for testing. Mix uniformly, but gently. Avoid foaming. 4. CHROMOGEN-SUBSTRATE SOLUTION Ready to use as supplied. 5. STOP SOLUTION Ready to use as supplied. 6. ANTI-HUMAN SERUM AMYLOID A ELISA MICROPLATE Ready to use as supplied. Unseal Microtiter Pouch and remove plate from pouch. Remove all strips and wells that will not be used in the assay and place back in pouch and re-seal along with desiccant. 7. HUMAN SAA CALIBRATOR Add 1.0 ml of distilled or deionized water to the Human serum amyloid A calibrator and mix gently until dissolved. The calibrator is now at a concentration of 12.90 ug/ml (the reconstituted calibrator should be aliquoted and frozen if future use is intended). Human serum amyloid A standards need to be prepared immediately prior to use (see chart below). Mix well between each step. Avoid foaming. Standard ng/ml Volume added to 1x Diluent Volume of 1x Diluent 7 100 5 l SAA Calibrator 640 L 6 50 300 L standard 7 300 L 5 25 300 L standard 6 300 L 4 12.50 300 L standard 5 300 L 3 6.25 300 L standard 4 300 L 2 3.13 300 L standard 3 300 L 1 1.56 300 L standard 2 300 L 0 0 600 L 26-G Keewaydin Drive, Salem, NH 03079P: (800) 592-5726F: (603) 898-6854ts@alpco.comwww.alpco.com Page 3 of 6

STORAGE AND STABILITY The expiration date for the package is stated on the box label. 1. DILUENT The 5X Diluent Concentrate is stable until the expiration date. The 1X working solution is stable for at least one week from the date of preparation. Both solutions should be stored at 4-8 C. 2. WASH SOLUTION The 20X Wash Solution Concentrate is stable until the expiration date. The 1X working solution is stable for at least one week from the date of preparation. Both solutions can be stored at room temperature (16-25 C) or at 4-8 C. 3. ENZYME-ANTIBODY CONJUGATE Undiluted horseradish peroxidase anti-serum amyloid A conjugate should be stored at 4-8 C and diluted immediately prior to use. The working conjugate solution is stable for up to 1 hour when stored in the dark. 4. CHROMOGEN-SUBSTRATE SOLUTION The Substrate Solution should be stored at 4-8 C and is stable until the expiration date. 5. STOP SOLUTION The Stop Solution should be stored at 4-8 C and is stable until the expiration date. 6. ANTI-HUMAN SERUM AMYLOID A ELISA MICROPLATE Anti-Human serum amyloid A coated wells are stable until the expiration date, and should be stored at 4-8 C in sealed foil pouch with desiccant pack. 7. HUMAN SERUM AMYLOID A CALIBRATOR The lyophilized Human serum amyloid A calibrator should be stored at 4 C or frozen until reconstituted. The reconstituted calibrator should be aliquoted out and stored frozen (avoid multiple freeze-thaw cycles). The working standard solutions should be prepared immediately prior to use and are stable for up to 8 hours. INDICATIONS OF INSTABILITY If the test is performing correctly, the results observed with the standard solutions should be within 20% of the expected values. SAMPLE COLLECTION AND HANDLING Blood should be collected by venipuncture. The serum should be separated from the cells after clot formation by centrifugation. For plasma samples, blood should be collected into a container with an anticoagulant and then centrifuged. Care should be taken to minimize hemolysis, as excessive hemolysis can impact the results. Assay immediately or aliquot and store samples at -20 C. Avoid repeated freeze-thaw cycles. 1. Precautions For any sample that might contain pathogens, care must be taken to prevent contact with open wounds. 2. Additives and Preservatives No additives or preservatives are necessary to maintain the integrity of the specimen. Avoid azide contamination. 3. Known interfering substances Azide and thimerosal at concentrations higher than 0.1% inhibit the enzyme reaction. MATERIAL PROVIDED See "REAGENTS" 26-G Keewaydin Drive, Salem, NH 03079P: (800) 592-5726F: (603) 898-6854ts@alpco.comwww.alpco.com Page 4 of 6

MATERIALS REQUIRED BUT NOT PROVIDED Precision pipette (2 L to 1000 L) for making and dispensing dilutions Test tubes Microtiter washer/aspirator Distilled or Deionized H2O Microtiter Plate reader Assorted glassware for the preparation of reagents and buffer solutions Timer Anticoagulant (for preparation of plasma samples) ASSAY PROTOCOL DILUTION OF SAMPLES The assay for quantification of serum amyloid A requires that each test sample be diluted before use. A dilution of serum/plasma at 1:50 is appropriate for most samples. For absolute quantification, samples that yield results outside the range of the standard curve, a lesser or greater dilution might be required. If unsure of sample level, a serial dilution with one or two representative samples before running the entire plate is highly recommended. To prepare a 1:50 dilution of sample, transfer 6 L to 294 L of diluent. This gives a 1:50 dilution. Mix thoroughly. PROCEDURE 1. Bring all reagents to room temperature before use. 2. Pipette 100 μl of Standard 0 (0.0 ng/ml) in duplicate Standard 1 (1.56 ng/ml) in duplicate Standard 2 (3.13 ng/ml) in duplicate Standard 3 (6.25 ng/ml) in duplicate Standard 4 (12.50 ng/ml) in duplicate Standard 5 (25 ng/ml) in duplicate Standard 6 (50 ng/ml) in duplicate Standard 7 (100 ng/ml) in duplicate 3. Pipette 100 μl of sample (in duplicate) into pre-designated wells. 4. Incubate the microtiter plate at room temperature for sixty (60 ± 2) minutes. Keep plate covered and level during incubation. 5. Following incubation, aspirate the contents of the wells. 6. Completely fill each well with appropriately diluted Wash Solution and aspirate. Repeat three times, for a total of four washes. If washing manually: completely fill wells with wash buffer, invert the plate then pour/shake out the contents in a waste container. Follow this by sharply tapping the wells on absorbent paper to remove residual buffer. Repeat 3 times for a total of four washes. 7. Pipette 100 μl of appropriately diluted Enzyme-Antibody Conjugate to each well. Incubate at room temperature for twenty (20 ± 2) minutes. Keep plate covered in the dark and level during incubation. 8. Wash and blot the wells as described in Steps 5 and 6. 9. Pipette 100 μl of TMB Substrate Solution into each well. 26-G Keewaydin Drive, Salem, NH 03079P: (800) 592-5726F: (603) 898-6854ts@alpco.comwww.alpco.com Page 5 of 6

10. Incubate in the dark at room temperature for precisely ten (10) minutes. 11. After ten minutes, add 100 μl of Stop Solution to each well. 12. Determine the absorbance (450 nm) of the contents of each well. Calibrate the plate reader to manufacturer s specifications. STABILITY OF THE FINAL REACTION MIXTURE The absorbance of the final reaction mixture can be measured up to 2 hours after the addition of the Stop Solution. However, good laboratory practice dictates that the measurement be made as soon as possible. RESULTS 1. Subtract the average background value from the test values for each sample. 2. Using the results observed for the standards construct a Standard Curve. The appropriate curve fit is that of a four-parameter logistics curve. A second order polynomial (quadratic) or other curve fits may also be used. 3. Interpolate test sample values from standard curve. Correct for sera dilution factor to arrive at the serum amyloid A concentration in original samples. LIMITATION OF THE PROCEDURE 1. Reliable and reproducible results will be obtained when the assay procedure is carried out with a complete understanding of the information contained in the package insert instructions and with adherence to good laboratory practice. 2. Factors that might affect the performance of the assay include proper instrument function, cleanliness of glassware, quality of distilled or deionized water, accuracy of reagent and sample pipetting, washing technique, incubation time or temperature. 3. Do not mix or substitute reagents with those from other lots or sources. APPENDIX A REFERENCE SERUM INFORMATION One vial containing a Reference Serum is included with this kit. Please refer to the enclosed Product Profile Sheet for lot-specific information. Please note the following: 1. The Reference Serum is stable until the expiry date. 2. The Reference Serum should be diluted as appropriate to fit within the standard range curve. Refer to the Dilution of Samples section of the protocol for instructions. 3. While pipetting the samples (Procedure section), also pipette the Reference Serum in duplicate. 26-G Keewaydin Drive, Salem, NH 03079P: (800) 592-5726F: (603) 898-6854ts@alpco.comwww.alpco.com Page 6 of 6