Complex process High costs

Similar documents
Complex process High costs

Complex process High costs

1 Delivery. 4 Control. 3 Unpacking. 2 Storage. 6 Cleaning. 8 Control. 9 Packaging of the kit. 11 Surgery. 16 Traceability. 18 Packaging of the kit

PL ATING SYSTEM. Pre-contoured implants Versatile fixation system Hexalobe screw recess design Locked fixation

ACTIV ANKLE DISTAL TIBIA PLATE MEDIAL MALLEOLUS INNOVATION MEANS MOTION. DUALTEC SYSTEM II and III

INNOVATION means MOTION ALIANS ELBOW OLECRANON. Narrow and standard plates Polyaxial locking technology Bendable precontoured implants

ALIANS ELBOW & OLECRANON. INNOVATION means MOTION. Distal humerus and olecranon plating system Polyaxial locking technology Precontoured implants

ACtiv ankle. INNOVATION means MOTION. Precontoured implants Polyaxiality of 20 2 surgical approaches : lateral and posterolateral

ACTIVMOTION HIGH TIBIAL OSTEOTOMY PL ATE

INNOVATION means MOTION ALIANS ELBOW POLYAXIAL LOCKING FIXATION. 3 types of construct Polyaxial locking technology Bendable precontoured implant

Astrid Modular Forefoot System. Surgical Technique

NeoFit. Metatarsophal angeal Arthrodesis Pl ate

Variable Angle LCP Forefoot/Midfoot System 2.4/2.7. Procedure specific plates for osteotomies, arthrodeses and fractures of the foot.

Foot & Ankle. EasyClip. Osteosynthesis Compression Staples. Foot & Ankle

MetaCun DuoMetaCun. Midfoot Fusion Locking Plate System. Surgical Technique and Ordering Information

Foot & Ankle. Smart Toe II. Intramedullary Implant. Operative Technique. Foot & Ankle

DYNAMIC, TRANSVERSE COMPRESSION. Low Profile, Anatomic Design, Type II Anodized. Mechanical Compression Designed to Stimulate the Fusion Process

O.S.2-C & O.S.2-V. Static Staple - Stainless steel

3. Insert Tocar Sleeves Insert the NCB tissue protection sleeve assembly 1.6 to 10mm through a skin incision (Fig. 38).

Anchorage. Foot & Ankle. Plating System. Operative Technique

Compression Screw 3.2 Bioabsorbable. Product information

AxSOS Locking Plate System

Technique Guide Lapidus Arthrodesis System

MetaFix Ludloff Plate

Technique Guide KISSloc Suture System

Integra. surgical technique. Advansys Midfoot Plating System. eng. D.L.P. Dorsal Lisfranc Plate. M.L.P. Medial Lisfranc Plate

LOWER EXTREMITIES SINGLE-USE INSTRUMENTATION SURGICAL IMPLANTATION TECHNIQUE. First Metatarsal Phalangeal Joint FOOT THE DIFFERENCE IS MOVING.

Lapidus Arthrodesis System Instructions for Use

AxSOS. Locking Plate System. Operative Technique. Small Fragment Basic Fragment

A locking plate system that expands a surgeon s options in trauma surgery. Zimmer NCB Plating System

ToeMobile. Surgical Technique. Great Toe Endoprosthesis

O.S.2-C. Compression staple PEEK

SMV Scientific Bone Plate and Screw System Surgical Technique

INTRAMEDULLARY NAILING TIBIA AND FEMUR 1.3 TIBIAL AND FEMORAL NAILING FEMORAL NAILING WITH RETROGRADE INSERTION IMPLANTS AND OPERATING MANUAL

Flower Medium Headless & Cannulated Screws

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

DARCO. Bow 2 Plate SURGIC AL TECHNIQUE

Merete BLP. Surgical Technique. - Bunion Locking Plate - Low Profile Locking Bone Plate System

ORION Screw System PRODUCT INFORMATION

FlexitSystem EFFICIENT MOBILITY. High Tibial Opening Wedge Osteotomy (HTO)

Hoffmann II Micro External Fixation System. Indications for the Hand

NCB Distal Femur System. Surgical Technique

Angle-stable Foot plate system Pedus-O and Pedus-U

SpeedTip CCS 2.2, 3.0

Integra. ADVANSYS Plating System SURGICAL TECHNIQUE

fassier DUVal TelescoPIc IM system s RESCUE SYSTEM 2.0

Thoracolumbar Spine Locking Plate (TSLP) System. A low-profile plating system for anterior stabilization of the thoracic and lumbar spine.

MPJ Implant System. Patents Pending Worldwide

Telya. Varisation staple. Surgical Technique. Irish Distributer: O'Mara Medical Tel

ORTHOLOC 3Di. Foot Reconstruction System SURGIC AL TECHNIQUE

3.0 mm Cannulated Screw System. Surgical Technique

CARTIVA. Synthetic Cartilage Implant SURGICAL IMPLANTATION TECHNIQUE. First Metatarsal Phalangeal Joint THE DIFFERENCE IS MOVING.

Flower Opening Wedge Plate

DARCO MFS. Locked plating system for reconstructive forefoot surgery.

Surgical Technique Carpal Fusion

FASSIER DUVAL TELESCOPIC IM SYSTEM S RESCUE SYSTEM 2.0

quad-plate eight-plate Easy application, solid growth for kids Not an actual patient

CANNULINK. Intraossous Fixation System SURGICAL TECHNIQUE

Hoffmann II Compact External Fixation System

Mandible Reconstruction Module Reference ence Guide

Surgical technique. Angular Stable X-Plate and 2-Hole Plate. For osteotomies, arthrodeses and fractures of the foot.

Surgical Technique. Cannulated Angled Blade Plate 3.5 and 4.5, 90

InCoreTM Lapidus System

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

Technique Guide Small Bone Fusion System

4Fusion. Shape Memory Implant. Operative Technique

Asnis. Micro Cannulated screw system. Xpress operative technique

A locking plate system that expands a surgeon s options in trauma surgery. Zimmer NCB Plating System

LCP Distal Tibia Plate

TSLP Thoracolumbar Spine Locking Plate

3. PATIENT POSITIONING & FRACTURE REDUCTION 3 8. DISTAL GUIDED LOCKING FOR PROXIMAL NAIL PROXIMAL LOCKING FOR LONG NAIL 13

The Flower Four Corner Fusion Plate

Contents. Chapter 1 4 Chapter Chapter Chapter Chapter 5 15

2.7 mm/3.5 mm LCP Distal Fibula Plate System. Part of the Synthes locking compression plate (LCP) system.

DuaFit. Proximal Interphal angeal Impl ant

NCB Proximal Humerus Plating System

CS 2.0. Product information. Intelligent innovations for a better life.

Integra. Solustaple Standard staple SURGICAL TECHNIQUE. Uni-Clip Compression staple. Products for sale in Europe, Middle-East and Africa only.

Gamma3 TM Fragment Control Clip

Contents - Merete Foot Family

pact SYSTEM Surgical Technique HEMISPHERICAL CEMENTLESS CUP SYSTEM MULTI-HOLE & RIM-HOLE Hip Knee Spine Navigation

Distal Radius Sterile Kit. Optimization And Efficiency You Can Rely On

Technique Guide. 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system.

Merete PlantarMAX Lapidus Plate Surgical Technique. Description of Plate

The Flower Proximal Humerus Plate

U2 PSA. Revision Knee. Surgical Protocol

CHARLOTTE Lisfranc. Recontruction System SURGICAL TECHNIQUE

ORTHOLOC CROSSCHECK TECHNOLOGY OVERVIEW FOR HOSPITAL VALUE ANALYSIS COMMITTEE

3.5 mm Locking Attachment Plate

The Flower Forefoot PROCEDURE GUIDE.

NCB Proximal Humerus System. Surgical Technique

The Flower Medial Column Fusion Plate

Femur Condylar Plate System Procedural Steps.

Mandible External Fixator II. Provides treatment for fractures of the maxillofacial area.

Zimmer ITST Intertrochanteric/ Subtrochanteric Fixation System. Abbreviated Surgical Technique

CC TRIO VERSAFITCUP. Surgical Technique. each to their own. Hip Knee Spine Navigation

Hoffmann II MRI External Fixation Systems. Hoffmann II MRI Hoffmann II Compact MRI Modular Systems for Upper Extremity Lower Extremity Pelvis

SURGICAL TECHNIQUE CHI. Cannulated Hemi Implants 1 ST MPJ ARTHROPLASTY

Surgical Technique. Targeter Systems Overview

Hand Fracture System. Surgical Technique

Transcription:

MTP

With a non sterile standard kit Calling on medical staff Constraints Complex traceability Contracted out sterilization Suppliers deadline Complex process High costs 1 Delivery 2 Storage 3 Unpacking 4 Control Stocks Control Cleaning Decontamination Sterilization HOSPITAL Surgeon 5 Decontamination 9 Packaging of the kit 13 Cleaning 6 Cleaning 10 Sterilization 14 Drying 7 Drying 11 Surgery 15 Control 8 Control 12 Decontamination 16 Traceability Bulky storage Incomplete kit 17 Restocking 18 Packaging of the kit 19 Sterilization 20 Storage Prevents an effective solution & a quick response Defective sterilization Incomplete kit Damaged instrumentation INCREASED RISKS NON OPTIMAL surgery URGENT SURGICAL CASES COMPROMISED

With the kit Safety TRACEABILITY Risk of contamination MTP Cost efficiency Efficiency Controlled stocks Simplified control 1 Delivery 2 Storage 3 Surgery Cleaning Decontamination Sterilization Surgeon An effective solution & a quick response Hospital Available when needed Sundry expenses READY-TO-USE FOR SURGERY Optimized handling of URGENT SURGICAL CASES Optimized storage with state-of-the-art implants

Safety: The Initial F - MTP kit is fully traceable and has a shelf life of 5 years. Its instrumentation and implants are always new and have never been opened or used before. Costs: Initial F - MTP is a cost-effective solution. The additional costs including cleaning, decontamination, sterilization of kits are cancelled. innovation Storage: Initial F - MTP kit can be easily stored in the operating room because of its small size. Buying procedure: Initial F - MTP facilitates buying procedures: restocking and orders are simplified, stock management is optimized. Contamination: The combination of sterile implants and sterile single-use instrumentation minimizes contamination risks.

Initial F - MTP kits Technical features Indications The implants of the Inital F - MTP range are intended for arthrodeses, fractures and osteotomies fixation and revision surgeries of the foot in adults. Contraindications Serious vascular deterioration, bone devitalization, Pregnancy. Acute or chronic local or systemic infections. Lack of musculo-cutaneous cover, severe vascular deficiency affecting the concerned area. Insufficient bone quality preventing a good fixation of the implants into the bone, Muscular deficit, neurological deficiency or behavioral disorders, which could submit the implant to abnormal mechanical strains. Allergy to one of the materials used or sensitivity to foreign bodies. Serious problems of non-compliance, mental or neurological disorders, failure to follow post-operative care recommendations. Unstable physical and/or mental condition. Plate for the first metatarso-phalangeal (MTP) joint arthrodesis Low profile plate: 1,7 mm thick, thus limiting soft tissue irritation risks while providing an optimized mechanical stability. 41 mm Range of precontoured plates: the design of this implant is the result of a proprietary state-of-the-art mapping technology to establish an optimized congruence between the plate and the bone. Oblong hole for pin to achieve compression without removing the pin and to ensure the guiding on the metatarsal. thickness 1,7 mm Hole for pin to temporarily stabilize the plate. Ramp oblong hole 36 mm Examples of applications: hallux rigidus, severe hallux valgus, polyarthritis 2 sizes of plates for the right (green plates) and left (blue plates) sides offering versatile solutions. PLATE BENDING Bending is only possible in the areas intended for this purpose. A bendable area must be bent only once, in one direction and not be performed excessively. The holes must be protected to avoid damaging the fixation.

Initial F - MTP kits Implants - Technical features Fixations and screws A single screw diameter: Ø2.8 mm. Both locking (SLT2.8Lxx) and non locking screws (RLT2.8Lxx) are available. Screw head is buried in the plate (1) to limit the risk of soft tissue irritation. Specific fixations for stable assembly Ramp oblong hole The ramp oblong hole enables a simple and controlled compression by its screwplate interface. The hexalobular screw stamp improves torque transmission. Screw head buried in the plate 1 Compression of the joint up to 1.5 mm Hexalobular stamp Single screw diameter Efficient locking Features : - The screw head is stopped in the hole by its cap, ensuring the locking, - The screw head is buried in the plate, - Plate and screws are all made of titanium alloy. Hole for transfixation screw The transfixation screw goes through the 1 st MTP joint providing stability to the assembly. Holes for converging screws in the distal and proximal areas Converging screws allowing a stable fixation of the system. Distal converging screws Proximal converging screws The threads under the screw head and inside the hole have strictly the same characteristics. Coaptation of both profiles during locking, limiting a cold welding risk and improving the removal properties. Transfixation screw 1 st MTP

Initial F - MTP kits Instrumentation - Technical features Convex and concave reamers Convex and concave reamers are used respectively to prepare the surfaces of the head of the first metatarsal and the base of the phalanx. Ensuring congruity of the surfaces. Reamers are available in 3 sizes : Ø16 mm Ø19 mm Ø22 mm Templates The Initial F - MTP templates are available separately and allow to quickly and simply determine the appropriate kit. REAMER TEMPLATE The template for Initial F - MTP - Reamers kits allows to determine the appropriate reamer diameter (Ø16 mm, Ø19mm or Ø22mm) to be used for joint preparation. Concave reamers Convex reamers Handle for guide gauge Before performing the drilling into the oblong hole, snap the handle for guide gauge on the Ø2.0 mm threaded guide gauge. Handle for guide gauge IMPLANT TEMPLATE The template for Initial F - MTP kits allows to determine the desired plate size prior opening a kit.

Initial F - MTP kits Surgical technique - Joint surfaces preparation Example: surgical technique with a Ø16 mm reamers kit ( KIT-MI16). 1. Dislocate the joint so as to expose the head of the first metatarsal and the proximal base of the first phalanx. 2. Use the reamers template to determine the appropriate reamers kit for joint preparation. 3. Insert the Ø1.6 mm pin through the head of the first metatarsal into the medullary cavity. With the chosen convex reamer, progressively remove the cartilage surface. Then, remove the reamer and the pin. 4. Expose the base of the phalanx and insert the Ø1.6 mm pin so as to achieve the proper alignment with the diaphysis. 5. Take a concave reamer with the same diameter as the convex reamer (determined at step 2). Insert it along the pin and perform the reaming until the cartilage surface has been removed. Then, remove the reamer and the pin.

Initial F - MTP kits Surgical technique Option 2 Example: surgical technique with a standard plate, size 1 (KIT-MD1D) 1. Select the correct kit according to the template. 2. Position the joint in the desired direction and stabilize it using a Ø1.6 mm pin. Then, position the plate and stabilize it temporarily by inserting a Ø1.2 mm pin into the dedicated oblong hole pin. Option 1 3. Lock the Ø2.0 mm threaded guide gauge into the distal lateral hole and perform the drilling. Option 1 - Determine the screw length using the gauge. Option 2 - Determine the screw length using the length gauge. Option 2 (1) Option 1 Final result 4. Insert the Ø2.8 mm green locking screw with the screwdriver. Repeat the same procedure for the most distal hole (1). 5. Snap the handle for guide gauge and perform the drilling using the assembly into proximal part of the ramp oblong hole. Option 1 - Determine the screw length using the gauge. Option 2 - Determine the screw length using the length gauge. 6. In the ramp oblong hole, insert a Ø2.8 mm yellow non locking screw and perform the compression using the screwdriver. Insert the Ø2.8 mm green locking screws into the 2 proximal holes following the steps 2 & 3, then remove the pins. Drill through the distal hole dedicated for the transfixation screw. Finalized the osteosynthesis by inserting a Ø2.8 mm yellow non-locking screw using the screwdriver.

Initial F - MTP kits References INITIAL F - MTP KITS Ref. Description KIT-MD1D 1 st MTP Arthrodesis kit - Right - Size 1 KIT-MD1G 1 st MTP Arthrodesis kit - Left - Size 1 KIT-MD2D 1 st MTP Arthrodesis kit - Right - Size 2 KIT-MD2G 1 st MTP Arthrodesis kit - Left - Size 2 INITIAL F - MTP KITS - INSTRUMENTATION CONTENT Description Ø2.0 mm quick coupling drill bit - L 125 mm 1 Ø2.0 mm threaded guide gauge for Ø2.8 mm screws 1 Length gauge for Ø2.8 and Ø3.5 mm screws - L 8-40 mm 1 T8 prehensor screwdriver 1 Handle for guige gauge 1 Pin Ø1.2 L70 mm 2 Pin Ø1.6 L100 mm 1 NB : Supplemental screws are available in sterile package (cf. : Initial F - MTP additional kits, additional implants) INITIAL F - MTP KITS - IMPLANTS CONTENT PLATES LOCKING SCREWS Ø2.8 MM NON LOCKING SCREWS Ø2.8 MM QUANTITY PER KIT Ref. Description KIT-MD1D KIT-MD1G KIT-MD2D KIT-MD2G FMTDD1 1 st MTP arthrodesis plate - Size 1 - Right 1 - - - FMTGD1 1 st MTP arthrodesis plate - Size 1 - Left - 1 - - FMTDD2 1 st MTP arthrodesis plate - Size 2 - Right - - 1 - FMTGD2 1 st MTP arthrodesis plate - Size 2 - Left - - - 1 SLT2.8L14 Locking screw Ø2.8 mm - L 14 mm 1 1 1 1 SLT2.8L16 Locking screw Ø2.8 mm - L 16 mm 2 2 2 2 SLT2.8L18 Locking screw Ø2.8 mm - L 18 mm 2 2 2 2 SLT2.8L20 Locking screw Ø2.8 mm - L 20 mm 1 1 1 1 RLT2.8L16 Non locking screw - Ø2.8 mm - L 16 mm 1 1 1 1 RLT2.8L18 Non locking screw - Ø2.8 mm - L 18 mm 1 1 1 1 RLT2.8L22 Non locking screw - Ø2.8 mm - L 22 mm 1 1 1 1 RLT2.8L26 Non locking screw - Ø2.8 mm - L 26 mm 1 1 1 1

Initial F - MTP - Additional sterile implants and kits References Additional implants Sterile screws packaged in the Supplemental sterile screw caddy NON LOCKING SCREWS - Ø2.8 mm * Ref. Description Qty RLT2.8L10-ST Non locking screw - Ø2.8 mm - L 10 mm - STERILE 1 RLT2.8L12-ST Non locking screw - Ø2.8 mm - L 12 mm - STERILE 1 RLT2.8L14-ST Non locking screw - Ø2.8 mm - L 14 mm - STERILE 1 RLT2.8L16-ST Non locking screw - Ø2.8 mm - L 16 mm - STERILE 1 RLT2.8L18-ST Non locking screw - Ø2.8 mm - L 18 mm - STERILE 1 RLT2.8L20-ST Non locking screw - Ø2.8 mm - L 20 mm - STERILE 1 RLT2.8L22-ST Non locking screw - Ø2.8 mm - L 22 mm - STERILE 1 RLT2.8L24-ST Non locking screw - Ø2.8 mm - L 24 mm - STERILE 1 RLT2.8L26-ST Non locking screw - Ø2.8 mm - L 26 mm - STERILE 1 RLT2.8L28-ST Non locking screw - Ø2.8 mm - L 28 mm - STERILE 1 RLT2.8L30-ST Non locking screw - Ø2.8 mm - L30 mm - STERILE 1 RLT2.8L32-ST Non locking screw - Ø2.8 mm - L32 mm - STERILE 1 RLT2.8L34-ST Non locking screw - Ø2.8 mm - L34 mm - STERILE 1 * Yellow anodized LOCKING SCREWS - Ø2.8 mm * Ref. Description Qty SLT2.8L10-ST Locking screw - Ø2.8 mm - L 10 mm - STERILE 1 SLT2.8L12-ST Locking screw - Ø2.8 mm - L 12 mm - STERILE 2 SLT2.8L14-ST Locking screw - Ø2.8 mm - L 14 mm - STERILE 3 SLT2.8L16-ST Locking screw - Ø2.8 mm - L 16 mm - STERILE 3 SLT2.8L18-ST Locking screw - Ø2.8 mm - L 18 mm - STERILE 3 SLT2.8L20-ST Locking screw - Ø2.8 mm - L 20 mm - STERILE 2 SLT2.8L22-ST Locking screw - Ø2.8 mm - L 22 mm - STERILE 2 SLT2.8L24-ST Locking screw - Ø2.8 mm - L 24 mm - STERILE 1 SLT2.8L26-ST Locking screw - Ø2.8 mm - L 26 mm - STERILE 1 SLT2.8L28-ST Locking screw - Ø2.8 mm - L 28 mm - STERILE 1 SLT2.8L30-ST Locking screw - Ø2.8 mm - L30 mm - STERILE 1 SLT2.8L32-ST Locking screw - Ø2.8 mm - L32 mm - STERILE 1 SLT2.8L34-ST Locking screw - Ø2.8 mm - L34 mm - STERILE 1 * Green anodized Additional instrumentation kits Convex & Concave reamers SINGLE USE CONVEX AND CONCAVE REAMERS - STERILE PACKAGING Ref. Description Qty KIT-MI16 KIT-MI19 KIT- MI22 Ø16 mm reamers kit for 1 st MTP arthrodesis Ø19 mm reamers kit for 1 st MTP arthrodesis Ø22 mm reamers kit for 1 st MTP arthrodesis - Ø16 mm Initial convex reamer - Ø16 mm Initial concave reamer - Pin Ø1.6 L100 mm x 2 - Ø19 mm Initial convex reamer - Ø19 mm Initial concave reamer - Pin Ø1.6 L100 mm x 2 - Ø22 mm Initial convex reamer - Ø22 mm Initial concave reamer - Pin Ø1.6 L100 mm x 2 Removal and rescue kits Sterile instruments REMOVAL AND RESCUE KITS Ref. Description Content KIT-REMOVE-2 Removal kit for T8 hexalobe - 1 x T8 Prehensor Screwdriver KIT-RESCUE-4 Rescue kit for Initial MTP - 1x Ø2.0 mm threaded guide gauge for Ø2.8 mm screws - 1x Ø2.0 mm quick coupling drill bit L125 mm. Templates Sterile templates INITIAL F - MTP TEMPLATES Ref. Description ANC808 1 st MTP arthrodesis plates template ANC846 1 st MTP arthrodesis reamers template The information presented in this brochure is intended to demonstrate a Newclip Technics product. Always refer to the package insert, product label and/or user instructions before using any Newclip Technics product. Surgeons must always rely on their own clinical judgment when deciding which products and techniques to use with their patients. Products may not be available in all markets. Product availability is subject to the regulatory or medical practices that govern individual markets. Please contact your Newclip Technics representative if you have questions about the availability of Newclip Technics products in your area.

KIT-MD1D Example of kit content. 26 mm 22 mm 18 mm 16 mm 1 1 1 1 1 2 2 1 Non locking screws Ø2.8 mm 1 2 1 1 1 1 NEWCLIP TECHNICS PA de la Lande Saint Martin - 45 rue des Garottières 44115 Haute-Goulaine - France Tel : +33 (0)2 28 21 37 12 - Fax : +33 (0)2 40 63 68 37 orders@newcliptechnics.com - www.newcliptechnics.com 20 mm 18 mm 16 mm 14 mm Locking screws Ø2.8 mm NEWCLIP USA 642 Larkfield Center Santa Rosa CA 95403, USA Phone : + 1 707 230 5078 customerservice@newclipusa.com - www.newclipusa.com 1 Right foot 1 st MTP Arthrodesis Size 1 15 mm 36 mm Brochure EN - Initial-F - MTP - Ed.1-11/2017 - Medical devices: class IIb - CE0120 SGS UK - US Class: II - Read labeling and instructions before use. Non contractual pictures.