Ultrasonic Cavitation. Collagen Facial Remodeling Body Shaping Slimming Cellulite Reduction Skin Tightening. Fat Elimination.

Similar documents
FEB-2015 ISSUE. Dr. David Pudukadan

Superior RF Multi-Treatment Platform

Superior RF Multi-Treatment Platform

VelaShape II. Cellulite Treatment & Body Contouring. Science. Results.Trust.

An In-Depth Examination of Radiofrequency Assisted Liposuction (RFAL)

Dual modality body shaping study with RF and IR technologies utilizing SharpLight s FormaxPlus Platform.

A G E N D A. I. Non-Invasive Body Contouring II. Benefits III. Treatment Options IV. Treatment Zones V. Q&A VI. Media VII.Results

Strong sound wave fat system

Focused Ultrasound Body-shaping system Beijing Sanhe Beauty S & T Co.,Ltd

Treatment Principle. A vacuum elevates the target tissue, bringing it closer to the energy. Infrared light(ir) directly he -ats the targeted area.

Contour Your Body Quickly and Comfortably!

PARABOLA SLENDERIZING METHOD

Reduces the appearance of cellulite and improves the appearance of the skin.

Syneron Raises the Bar in Energy-Based Body Shaping

Non-Ablative Rejuvenation

NEW IN-DEMAND AESTHETICS IN ONE PLATFORM TECH BREAKTHROUGH PLUS

Focused Ultrasound Body shaping system

AESTHETIC TECHNOLOGIES. Proven Marketing and Aesthetic Technologies Designed to Maximize Your Earning Potential

NOVEL MULTI-SOURCE PHASE-CONTROLLED RADIOFREQUENCY TECHNOLOGY FOR NON- ABLATIVE AND MICRO-ABLATIVE TREATMENT OF WRINKLES, LAX SKIN AND ACNE SCARS

Cryolipolysis Slimming Machine With Cavitation, RF, Lipo Laser User Manual

Battle of the Bulge with BodyTite The Latest Chapter in Liposuction

A Never Obsolete Face and Body Platform

The Future of Body Contouring Minimally Invasive Procedures

Full Body Contouring Experience

Acoustic radial wave. Features

NEW! FEATURING LATEST INNOVATIONS

RF Smart evolution RF Med mono RF Med plus Renew Face & Body RF Med bipolar desk

Personalized Body Sculpting: The Next Evolution

High Intensity Focused Ultrasound Facial Skin Lifting

Reduces the appearance of cellulite and improves the appearance of the skin.

Innovative laser diode system for body shaping and fat reduction

Princes Street, Dunedin

High Power CO2 Laser + Micro-needle Fractional RF

doublo-s 2nd Generation HIFU For Intenal Purpose

Hands-on: Lasers. NonAblative Rejuvenation

Evaluation of the wound healing response post deep dermal heating by fractional RF: INTRAcel

PHOTOTHERAPY: WHAT DO WE KNOW AND HOW DOES IT WORK? Suite 3/36 O'Riordan Street Alexandria, Sydney NSW Australia

Department of Dermatology Faculty of Medicine Siriraj Hospital, Mahidol University Bangkok, THAILAND

Evaluation of the wound healing response post - deep dermal heating by fractional RF: INTRACEL

Golden standard for non-invasive body shaping Focused

FREEZE TIME REVERSE AGING

Hands-free Treatment The Freedom to Do More

Can you believe that the ultrasonic waves are used for cleaning purpose???

Arisa Ortiz, MD Director, Laser and Cosmetic Dermatology Assistant Clinical Professor Department of Dermatology UC San Diego

Rumpa Linpiyawan, MD. Biography - Certified Board of Internal Medicine - Certified Board of Dermatology, Board of Family Medicine

SPECIAL TOPIC. Cosmetic Dermatology Center, McLean, VA b. Art of Skin, MD, Solana Beach, CA c. Dermatology Associates, Seattle, WA

Bipolar Radio Frequency Beauty Device SE-ST34 User Manual

The Art of Body Shaping

The ultimate Technology for Cellulites and Slimming.

WHERE HEAT MEETS COLD

IT S A FACT TECHNOLOGY EVOLVES. WE MAKE SURE YOU CAN TOO.

The Art of Body Shaping

BODY PROTOCOLS. Applies to 3D-Ultimate, 3D-lipomed & 3D-lipo

A Smarter Way To Sculpt. Frequently Asked Questions

BETTER THAN EVER. Brand new 360 technology for shorter treatments with more consistent outcomes.

Mona SC-2 Ultra Pulse Co2 Fractional laser system. Beijing Sanhe Beauty S & T Co.,Ltd

DISCOVER. a new YOU FAT LOSS INCH LOSS BODY SHAPING FIGURE CORRECTION ANDHERI BANDRA GRANT ROAD.

Low Level Laser treatment has revolutionized the Aesthetic Industry.

Newest extravagant Slimming system. Lipo laser Cryo Vshape

6-1 Cellulite Removal Tripolar RF Diode Laser LLLT Lipo Laser Cavitation Machine. Use Manual

Dual wavelength (1540nm nm) mixed technology for fractional resurfacing in skin rejuvenation Background

Icon specifications. Handpiece compatibility

AESTHETICS CLINIC & ULTIMA GSTAAD

ALTERNATIVE TREATMENT

QUOTATION SHEET. Weight Loss Slimming Machine Package size(cm) 1.5Mhz Tripolar RF for face; 5.5Mhz Bipolar RF eyes beauty. 1.5Mhz Bipolar RF eyes;

Awide range of technologies are available to perform esthetic

PHYSICIANS GUIDE. Understanding Fraxel TM Laser Treatment

Treatments & Pricing. Specialists In Non-Surgical Aesthetic Treatments.

Presentation Product & clinics

Clinical Efficacy and Statistical Evaluation of INTRAcel Treatment

HISTOLOGICAL EVALUATION AFTER RADIOFREQUENCY TREATMENT FOR FACE REJUVENATION AND CELLULITIS

Cold Laser Program ML830

M & T srl. medical & technology

NEOGENEVO ENERGIST NITROGEN PLASMA SYSTEM SKIN RESURFACING SKIN REJUVENATION SKIN TIGHTENING SKIN REGENERATION SEVERE AND FINE WRINKLE REDUCTION

Treat Your Patients Better

Supplement to July/August 2015 CLINICAL CASE BOOK SELECTIVE RADIOFREQUENCY FAT REDUCTION IN PRACTICE

Relaxes. Drains. Detoxifies. Reduces. Reshapes. Fills. Tones. Remodels. Firms. Sculpts. Cuddles

Glossary of Terms. Ablation- removal of tissue: the removal of unwanted tissue from the body by surgical or other means

Multi-Application Platform. Summary of Peer-reviewed Articles for Various Clinical Indications April 2016

NO MORE NEWS AN EVIDENCE BASED APPROACH ON LASERS IN SKIN OF COLOR PATIENTS DR. EDUARDO WEISS, M.D., FAAD

ONDA INNATE ABILITY. The Coolwaves TM Revolution. Smart and Enhanced Microwaves that Excel in All Body Contouring Applications:

The Professional Choice

the 10 Minute Success

body Reshape your body Renew your look Redefine you sculpting center Dramatic Aesthetic Results With a Spa-Like Feel

Overview SKABA7. Using radio frequency to rejuvenate the skin and improve body contour

CLINICAL STUDY REDUCTION OF LOCALIZED AND GENERALIZED ADIPOSE TISSUE BY CONTROLLED COOLING IN ABDOMEN AREA

Chapter 19: FotoFacial RF Pro Parameters


Aging, Photo damaged Skin

NOVIN medical engineering Co. Designer and manufacturer of physiotherapy equipment

Radiofrequency for Facial Skin Tightening

world [2]. One product of such innovative engineering in is the ultrasound-assisted liposuction

LX7 (Luxury) New automatic system

R-slimming Medical Systems

Ultra Skin Needling. Rejuvenate Supports Collagen Regeneration Scar Improvement. For your best ever skin.

CO 2 Laser Treatment Periocular Area. Prof. G.Cannarozzo

1.2 Please don t assemble or operate this equipment while you are near the water or your hands are wet. Notice that don t pour the liquid on it.

StarLux Fractional Non-Ablative Skin Resurfacing

ProFractional. ProFractional Therapy. Tunable Fractional Solution. Advanced Fractional Aesthetic Laser Surgery

Find A Better You 856 Waterbury Falls Dr. #100B O Fallon, MO (636) How Does Body Contouring Work?

Transcription:

Ultrasonic Cavitation RF VACUUM LED Five-in-one Technologies: US RF Bi & Tri-Polar Vacuum LED Multiple Modalities for Treating Multiple Indications in a Single Pass Collagen Facial Remodeling Body Shaping Slimming Cellulite Reduction Skin Tightening Fat Elimination Non-Invasive Fat Reduction with Zero Downtime Experience the POWER of 100+ Pre-Set ismart Software Programs for PERFECT SYNERGY Immediately Perform the Most Popular & Profitable Aesthetic Services Today WWW.SYBARITIC.COM

TRIO ishape Synergy Synergy from the Greek, meaning working together refers to the scientific phenomenon in which two or more discrete influences or agents acting together create an effect greater than that predicted by knowing only the separate effects of the individual agents. Synergy is often used to describe situations where the whole is greater than the sum of its parts. The synergistic combination of each of the four distinct TRIO ishape modalities radiofrequency (RF), ultrasound cavitation, vacuum/suction and (red) LED phototherapy shown below provides aesthetic benefits far beyond the simple addition of each individual technology. This is because each modality has a specific mechanism of action which produces a distinctive physiological result which can often be enhanced by the addition of other modalities. For example, if you follow an ultrasound cavitation treatment for non-invasive body contouring with vacuum suction you can significantly enhance the treatment results and show immediate improvement in body contour by immediately mobilizing and moving the free liquefied fat to the nearest lymph nodes for more efficient drainage and elimination. Ultrasonic Cavitation RF VACUUM LED FACE TRIO ishape Treatments for the Face RF or RF + LED or RF + LED + Vacuum LED or LED + Vacuum or Vacuum BODY TRIO ishape Treatments for the Body RF or RF + LED or RF + LED + Vacuum or LED or LED + Vacuum or Vacuum Ultrasound Cavitation or Ultrasound Cavitation + RF or Ultrasound Cavitation + LED Ultrasound Cavitation + Vacuum or Ultrasound Cavitation + RF + LED 1 Ultrasound Cavitation + RF + Vacuum or Ultrasound Cavitation + RF + LED + Vacuum

FACE LIFT BODY...by 2011 more than 36 million procedures generating $8 billion professional fees... TRIO ishape Markets Demand for each of the services which can be performed with the TRIO ishape system (Non-Invasive Fat Removal/Body Shaping/Cellulite/Wrinkles/Skin Tightening) is growing at an explosive rate. Current trends in non-invasive fat removal (Body Shaping) procedures indicates the recent emergence of new technologies using less invasive treatment modalities than traditional liposuction and similar procedures. Body shaping encompasses a range of procedures that target size and weight reduction, as well as toning, firming and cellulite treatment. Skin tightening procedures address wrinkles and skin laxity on the face and body. In 2006, over 14 million procedures were performed in this category, generating in excess of $4 billion in practitioner fees. By 2011, more than 36 million procedures in these areas were projected, producing over $8 billion in professional fees. It is projected that non-invasive ultrasound cavitation fat removal service volume will increase by an unprecedented 70% annually during the next several years. RF skin tightening procedures are expected to demonstrate even stronger growth (more than 194% per year for collective RF procedures including skin tightening, fat removal and collagen renewal procedures). The estimated 4 million skin tightening and body shaping procedures performed in 2009 is expected to more than double to 8.7 million by 2014. Services provided by LED light array devices are also expected to increase dramatically by over 50% per year- largely resulting from new product introductions and applications. 70% Annually 194% per year 50% per year 2

Introducing... the New TRIO ishape Larger Color Touch Screen & Intergrated Pre-Set Modality & Parameter Options Make Operator s Instant Experts TRIO ishape Proprietary ismart Software The TRIO ishape proprietary software allows the operator to select and adjust each modality (RF, cavitation, and vacuum suction) to treat a wide variety of popular indications including cellulite reduction, body shaping/slimming, skin tightening and wrinkle reduction. The large, full color touch screen display also allows the operator to select the target treatment area- body (arms, legs, abdomen, etc.) or face (forehead, cheeks, etc.). In addition, the TRIO ismart software provides pre-set recommended parameter settings and directional stroking instructions for each treatment indication, making the treatments as easy to administer as they are effective. 3

The Basic RF TRIO ishape Radiofrequency ( RF ) Energy The TRIO ishape RF energy is a form of electromagnetic energy with a wide frequency range (3 khz to 300 MHz). RF energy affects the skin and tissue by utilizing various frequencies of radio waves that cause thermal effects in the skin in a similar but different manner...by 2011 more than 36 million procedures generating $8 billion professional fees... than aesthetic lasers, infrared devices and intense pulsed light sources. RF energy is also photonic energy but unlike lasers and IPL systems RF photons are not absorbed by skin chromophores resulting in the production of heat. Instead, RF energy is delivered to the body via a variety of different frequencies, electrode configurations and technologies. Body cells do not interpret RF current as electricity ; rather it is treated as an energy source. Skin layers act like resistors in series to the RF current and -- depending on the resistance and composition of the skin (and tissue) layers -- they heat up to varying degrees (much like a light bulb heats up when electricity passes through it). In general (depending on the frequency of the RF current utilized), fat cells are more resistant to RF current than other skin cells because oil is less conductive to electrical current than water (and normal skin cells are comprised mainly of water, whereas fat cells are lipids ). Because fat cells have a higher resistance than epidermal and dermal skin cells, fat cells heat up more quickly than other skin tissue. The treatment indication, the body (or face) area being treated, the duration of the treatment, and the amount of TRIO RF energy applied can be selected on the control panel by the operator and the TRIO system will automatically deliver RF energy to the proper skin or tissue layer for optimal results. The only way to make sure you are performing proper RF treatments that will result in both immediate skin tightening and long-term collagen reformation is to make sure you are reaching external skin temperatures of approximately 39 degrees C. and maintaining this temperature in each treatment grid for at least one full minute. In order to do this, you need to use an accurate skin thermometer during each treatment. The TRIO ishape s integrated IR Thermometer makes monitoring of either external or internal skin temperature during treatment a breeze. TRIO ishape Tri-Polar RF Skin Tightening Modality (5 mhz) TRIO ishape Ultrasound Cavitation Modality (35 khz) Stratum Corneum Epidermis Dermal Epidermal Junction(DEJ) Dermis Stratum Lucidum Stratum Granulosum Stratum Spinsum Stratum Basal Subcutaneous Dermal Junction (SDJ) Subcutaneous Fat Layer Muscle Layer 4

Cellulite /Slimming Emerging RF Skin Tightening Technology Has Arrived Controlled thermal energy is a method for contracting loose, lax skin through the well-known mechanism of collagen denaturation. Heat-induced denaturation of collagen typically occurs at temperatures of about 65 degrees C. Radio frequency (RF) energy in a specific frequency range has long demonstrated its efficiency in rehabilitative diathermy and for heating tissue in electro-surgery. RF energy is also being widely used today for a variety of aesthetic and dermatological applications. RF energy has been shown in multiple studies to effectively tighten tissue, reduce wrinkles, and produce a noticeable skin lifting effect. Selective RF electrothermolysis via offers a safe and effective non-ablative method to improve tissue laxity, rhytides and cellulite. RF Energy Delivery Via Electrodes RF energy is delivered to the tissue by means of electrodes which are applied to the skin surface. The two traditional electrode configurations for the delivery of RF energy are bi-polar (two electrodes) and mono-polar (a single electrode and a grounding pad). The two methods differ in their derived energy field, but the resultant energy-tissue interaction is similar. Mono-polar RF systems are generally not recommended for treating the face. This is because mono-polar systems concentrate high-power RF density on a single surface electrode, Electromagnetic Spectrum 0.0001nm 0.01nm 10nm 1000nm 0.01cm 1m 90m 100m Gamma rays Visible Light 5 MHz/90m Aesthetic Frequency 10 8 5 2 1 Hz Proprietary Modulation Frequencies (MF) 10000 m which provides deep but random distribution of RF energy. With mono-polar systems, RF energy gradually diminishes in both density and power as it travels further from the source of emitted power. Mono-polar current travels via the path of least resistance to a large grounding pad typically located on the other side of the body. The high power required for mono-polar systems and the high concentration of power at the skin surface has raised concerns about causing the undesirable loss of facial fat and other adverse events. X-Ray 400nm Ultra violet 700nm Infrared TRIO RF Radio Freq. Photon Properties ENERGY (Photons per quantum) INCREASING DECREASING FREQUENCY (Oscillations per cycle) Increasing (higher Freq.) Decreasing (lower freq.) 5 shorter wave WAVELENGTH (Wave peak to peak) longer wave

TRIO ishape Bi-Polar RF RF Safe & Effective for the Face & Body The TRIO ishape RF includes both bi-polar (two electrodes) and tri-polar RF (three electrodes) modalities for the ultimate versatility in the safe and effective delivery of popular aesthetic services including skin tightening, wrinkle reduction, slimming and cellulite reduction. With both the included facial and body bi-polar hand pieces, the RF current flows between two electrodes one positive and one negative in polarity, set a fixed distance apart. The RF current travels through the tissue in a predictable arc between the two electrodes. The distance between the two electrodes determines the exact area of RF energy delivery and the depth of penetration of the energy (and resultant tissue heating). No grounding pad is necessary with multi-polar systems. The predictable pattern and distribution of the TRIO bi-polar current in the tissue allows the operator to deliver RF energy in a manner that is safe, more precise and more controlled, providing a major advantage of bi-polar technology over mono-polar systems. TRIO ishape Tri-Polar RF Can Achieve a Uniform Multi-Layer Skin Heating The included TRIO ishape tri-polar hand pieces use three electrodes to deliver the RF energy to the underlying skin and tissue layers. The key advantages of the tri-polar modality is that the three electrodes focus the energy in the center between the three poles/electrodes. This focused delivery of RF energy provides higher treatment efficacy due to the highly focused electrical energy that requires much less total energy. The use of lower energy levels results in no patient discomfort during treatment, immediate results and faster treatments. In addition, the tri-polar configuration allows the achievement of variable depths of penetration, thereby resulting in simultaneous treatment of deep and superficial skin layers. This is important in achieving uniform, multi-layer skin heating. TRIO ishape s large and standard tri-polar radiofrequency RF handpieces include built-in IR infrared thermometers to provide continuous feedback for monitoring the external skin temperature or the temperature of the deeper dermal layers. Experts agree that the goal for efficacious and safe RF treatments should be the achievement of internal (i.e., dermal) temperature in a range between 48 and 50 C which relates to an external (i.e., dermal) skin temperature at the treatment location in a range between 38 and 40 C. NOTES: Surgeons and patients should also remember that skin tightening continues to improve several months after laser irradiation due to the delayed nature of neocollagenesis. The only way to make sure you are performing proper RF treatments that will result in both immediate skin tightening and long-term collagen reformation is to make sure you are reaching external skin temperatures of approximately 39 degrees C. and maintaining this temperature in each treatment grid for at least one full minute. In order to do this, you need to use an accurate skin thermometer during each treatment. The TRIO ishape s integrated IR Thermometer makes monitoring of either external or internal skin temperature during treatment a breeze. 6

The Science Ultrasonic Cavitation TRIO ishape Ultrasound Cavitation Non-Surgical Elimination of Adipose Tissue, Tissue Tightening & Improved Skin Tone The use of non-thermal ultrasound cavitation for the safe and non-invasive treatment of excess body fat and body contouring has taken the world by storm during the past several years. Traditional cavitation machines utilized the thermal effects of ultrasound, were non-selective and generally resulted in dangerously high skin temperatures often causing epidermal injurty and discomfort. Recent discoveries have shown that non-thermal cavitation utilizing mechanical stress waves to damage and adipocyte membrane integrity and remove fat without injuring the epidermis or other cells (i.e., nerves, blood vessels, etc.) in the adipose layer is the superior technology for noninvasive liposculpture results. The TRIO ishape system utilizes variable dual frequency ultrasound for deeper penetration and superior results in reducing the thickness of the adipose layers. The combination of two non-thermal ultrasound frequencies 28 khz AND 40 khz- is a breakthrough in body shaping technology. TRIO ishape proprietary Dual Frequency Low Intensity Cavitation Ultrasound (LICU) platform makes it the preferred system for many aesthetic body shaping applications. Variable Dual Frequency Ultrasound Through the use of its innovative dual frequency ultrasound generators, the TRIO ishape enables the operator to select from three different frequency options for more flexibility and greater results: 28 khz, 40 khz, and 28 khz/40 khz dual mode. With both RF and ultrasound, the lower the frequency used, the deeper the energy will penetrate into the tissue. Ultrasound energy can penetrate into the subcutaneous fat layer, and RF energy can penetrate to the deepest layers of the dermis. TRIO ishape Tri-Polar RF Skin Tightening Modality (5 mhz) TRIO ishape Ultrasound Cavitation Modality (35 khz) Stratum Corneum Epidermis Dermal Epidermal Junction(DEJ) Dermis Stratum Lucidum Stratum Granulosum Stratum Spinsum Stratum Basal Subcutaneous Dermal Junction (SDJ) 7 Subcutaneous Fat Layer Muscle Layer

1 2 3 Adipocytes at Rest The tissue heating at target depth Pores have formed on the adipoctes allowing contents to spill out TRIO ishape Ultrasound Cavitation SCIENCE Cavitation is defined as the formation of partial vacuums within a flowing liquid as a result of mechanical force and is described in the illustration shown below. When applied with sufficient intensity in aesthetic cavitation treatments, tiny vacuums or cavities (often referred to as bubbles ) are repeatedly generated inside the interstitial fluid between the tissue cells in a safe, controlled manner. 4 TRIO ishape Cavitation Phenomenon The traditional therapeutic applications of ultrasound energy such as physical rehabilitation have utilized primarily the thermal component of ultrasound s three mechanisms of tissue interaction. The TRIO ishape utilizes primarily the cavitation phenomenon resulting from the expansion and compression cycles inherent to the ultrasound waveform. Ultrasonic compression cycles exert positive pressure on fluid molecules, while expansion cycles exert negative pressure. Due to the relatively lower molecular cohesion forces found in low-density tissue like fat as compared with neighboring muscle tissue, nerves, or bone-- these rapidly alternating pressure gradients produce microcavities within the biological tissue. These micro-cavities or gas-filled bubbles are unstable in a low-density medium and have an increasing chance of implosion with ever-growing diameters. After prolonged exposure to the ultrasonic waves, most of the microcavities within the adipose tissue reach a critical volume and break down. This cumulative disruption causes the widespread damage of tissue infrastructure. The final result is a particulate cellular fragmentation with diffusion of the lipid matrix of the adipocytes (fatty acids or triglycerides) into the intercellular spaces. Free fatty acids released during a TRIO cavitation treatment will eventually be delivered to the liver and are processed in the normal pathways that nature has evolved for the transport and elimination of excess dietary fat. Water Glycerol and Free Fatty Acids move out into interstitial space. a. b. c. d. a. Cavitation bubbles oscillate and induce shear stresses on cells. b. High temperatures at the bubble core, created by bubble collapse, induce chemical changes in the surrounding fluid. c. Sudden collapse of bubbles sends shock waves capable of disrupting tissue and fat cell walls. d. Collapsing bubbles can also form high-velocity micro-jets which penetrate tissue or create secondary shock waves. 8

TRIO ishape Ultrasound Cavitation Results With the ultrasound cavitation modality included with the TRIO ishape system you can achieve results like liposuction without the risk of an invasive procedure. When applied in proper ultrasound frequencies and intensity levels to excess layers of subcutaneous fat, low frequency ultrasound waves can cause cavitation bubbles to implode against fat tissue, applying steady pressure until the fat cell membranes rupture. These ruptures allow the liquefied fat (mainly triglycerides) inside the fat cells to be emptied into the fluid between the fat cells (called the interstitial space ). The fat cell contents and the remaining cellular debris is then easily transported and eliminated via the lymphatic system. Ultrasound cavitation treatments help eliminate fat cells gradually and without the risk of unwanted lumps, bumps and side effects. The end result will be a body contour that is smooth, shapely and slimmer than you have been in years! Before & Afters Before Ultrasonic Cavitation After 9

Ultrasonic Cavitation RF TRIO ishape Tri-Polar RF (Radiofrequency) The TRIO ishape includes a convenient tri-polar RF modality for the thermal treatment of skin laxity, wrinkles, skin rejuvenation, cellulite and body fat. RF current is produced when charged particles flow through a closed circuit. As the electrical energy meets resistance in the tissue, the energy is transformed into heat. The generated heat is deposited at different depths in the dermis depending on the parameter settings and applicator used, resulting in immediate collagen contraction and long-term collagen regeneration. RF thermal treatments result in non-invasive improvement in wrinkles and skin laxity as well as cellulite and excess body fat. The proprietary TRIO ishape tri-polar RF handpiece enables the operator to cover larger surface areas and treat at greater skin depths than either mono-polar or bi-polar systems for faster and more effective RF treatment. TRIO ishape s large and standard tri-polar radiofrequency RF handpieces include built-in infrared thermometers to provide continuous feedback for monitoring the external skin temperature or the temperature of the deeper dermal layers. The goal for efficacious and safe RF treatments should be the achievement of internal (i.e., dermal) temperature in a range between 48 and 50 C which relates to an external (i.e., dermal) skin temperature at the treatment location in a range between 38 and 40 C. Ultrasound Cavitation Handset BODY Ultrasound Cavitation Frequency: 40 khz; 28 khz Dual Mode: 40/28 khz Tri Polar RF Handsets FACE & BODY Radiofrequency RF Carrier Frequency (CF): 1 MHz Tri-Polar Facial Hand Piece: Diameter 35 mm; Tri-Polar Body Hand Piece: Diameter 66 mm; Mini Face Hand Piece: Diameter 66 mm; with (3) three inter-changeable tips 10

VACUUM Vacuum Theraphy Science TRIO ishape Vacuum + Bi Polar + LED The TRIO ishape system includes a vacuum modality for specialized treatment of a variety of skin and body conditions including lifting, drainage, wrinkles, skin rejuvenation, tightening, cellulite, stimulation and activation. The unique vacuum modality provides the optimal method for increasing the circulation of both blood and lymph for improved tissue health and reduced edema and congestion. In addition, vacuum treatments can be combined with either (or both) LED and bi-polar RF for additional skin and body benefits. The addition of bi-polar RF adds the power of heat to any treatment, and the incorporation of the 630 680 nm LEDs enables the operator to deliver additional anti-aging and beauty benefits by directing precise amounts of photonic energy to the skin cells themselves. Vacuum + BiPolar RF Handsets + LED 11 FACE & BODY Radiofrequency Bi-Polar RF/Vacuum: Facial Hand Piece: Inner diameter 50 mm (with two LEDs); Bi-Polar RF/Vacuum Body Hand Piece: Inner diameter 80 mm (with six LEDs); LED

TRIO ishape Vacuum Therapy The TRIO ishape RF Vacuum Therapy modality included in each bi-polar RF handpiece enables the operator to treat with either continuous or pulsed negative pressure for extraordinary aesthetic results for a number of popular concerns including: Reduction in the Appearance of Cellulite Improved Skin Tone & Texture Improved Tissue Health Due to Improved Blood Flow Reduction in Edema and Problematic Lymphatic Circulation Improved Body Contour Due to Increased Tissue Metabolism & Blood Circulation 12

Tightens & Rejuvenates Stimulates Collagen Formation Reduces Cellulite & Wrinkles Reduces Pore Size Eliminates Excess Fat & Detoxifies 100+ ismart Software Pre-Set Programs Harmonized ismart Software V 4.0; Nine (9) Pre-set Treatment Areas: Face, Neck & Decollete, Abdomen, Buttocks, Legs, Arms, Feet, Hands, Breast. Large 10.4 True Color Touch Screen Monitor Technical Specifications Ultrasound / Modality Ultrasonic Cavitation Ultrasound Cavitation Frequency: 40 khz; 28 khz & Dual Mode; 40/28 khz Energy: 0 50 Joules; Continuous or Pulsed; Diameter of transducer: 50 mm Tri-Polar RF / Modality RF LED VACUUM Carrier Frequency: 1 MHz RF Energy: Adjustable 0 300 J. Tri-Polar Facial Hand Piece: Diameter 35 mm* Tri-Polar Body Hand Piece: Diameter 66 mm* Bi-Polar Mini Facial Hand Piece: Diameter 35 mm with (3) three interchangeable tips LED / Modality LED Wavelength: 620-670 nm LED Power: 60 ma LED Diameter (ea): 10 mm Vacuum + Bi-Polar RF / Modality Facial Hand Piece: Outer diameter 75 mm (with two LEDs) Body Hand Piece: Outer diameter 109 mm (with six LEDs) Vacuum Pressure: 740 mm Hg (maximum) Vacuum Flow: 80 L/min. (maximum) Duration of Suction & Deflation: Adjustable100 ms to 2 sec. Bi-Polar RF Energy: 0-300 J. RF Frequency: 1 MHz Device Weight: 63 lb. /29 kg. Electrical Requirement: 100/110 V or 200/220 V, 50-60 Hz Extended Warranty available. EU/CE certifications granted. * With Integrated IR Skin Thermometer 0197 Tel 1 (952) 888.8282 Fax 1 (952) 888.8887 info@sybaritic.com 2012 Sybaritic, Incorporated All Rights Reserved. Sybaritic, Global Aesthetic Solutions TXI.1.0112.2.I WWW.SYBARITIC.COM