Stent implantation into the patent ductus arteriosus in cyanotic congenital heart disease with duct-dependent or diminished pulmonary circulation

Similar documents
Debate: Should Ductal Stent Implantation be Considered for All Newborn Infants with Reduced Pulmonary Blood Flow?_Pros

Foetal Cardiology: How to predict perinatal problems. Prof. I.Witters Prof.M.Gewillig UZ Leuven

MDCT Evaluation of Tortuous Ductus Arteriosus

CONGENITAL HEART DISEASE (CHD)

East and Central African Journal of Surgery Volume 12 Number 2 November /December 2007

Congenital heart disease: When to act and what to do?

Departments of Paediatrics and Cardiology, Mater Dei Hospital, Malta

When is Risky to Apply Oxygen for Congenital Heart Disease 부천세종병원 소아청소년과최은영

PULMONARY ARTERY STENTING AFfER TOTAL SURGICAL CORRECTION OF RIGHT VENTRICULAR OUTFLOW TRACT OBSTRUCTIVE LESIONS

AORTIC COARCTATION. Synonyms: - Coarctation of the aorta

3/14/2011 MANAGEMENT OF NEWBORNS CARDIAC INTENSIVE CARE CONFERENCE FOR HEALTH PROFESSIONALS IRVINE, CA. MARCH 7, 2011 WITH HEART DEFECTS

Absent Pulmonary Valve Syndrome

IMAGES. in PAEDIATRIC CARDIOLOGY

5.8 Congenital Heart Disease

Deok Young Choi, Gil Hospital, Gachon University NEONATES WITH EBSTEIN S ANOMALY: PROBLEMS AND SOLUTION

INTERVENTIONAL PROCEDURES PROGRAMME

Aortography in Fallot's Tetralogy and Variants

Congenital Heart Defects

가천의대길병원소아심장과최덕영 PA C IVS THE EVALUATION AND PRINCIPLES OF TREATMENT STRATEGY

Hypoplastic Left Heart Syndrome: Echocardiographic Assessment

INTERVENTIONAL PROCEDURES PROGRAMME

Initial Experience Using the Palmaz Corinthian Stent for Right Ventricular Outflow Obstruction in Infants and Small Children

Perioperative Management of DORV Case

Screening for Critical Congenital Heart Disease

Neonatal Cardiac Interventions: An Indian Perspective

Hybrid Procedure of Bilateral Pulmonary Artery Banding and Bilateral Ductal Stenting in an Infant With Aortic Atresia and Interrupted Aortic Arch

Patent ductus arteriosus PDA

Cardiovascular Pathophysiology: Right to Left Shunts aka Cyanotic Lesions

Cardiovascular Pathophysiology: Right to Left Shunts aka Cyanotic Lesions Ismee A. Williams, MD, MS Pediatric Cardiology

Cardiac Emergencies in Infants. Michael Luceri, DO

Case Report International Journal of Basic and Clinical Studies (IJBCS) 2013;1(1): Elbey MA et al.

INTERVENTIONAL PROCEDURES PROGRAMME

9/8/2009 < 1 1,2 3,4 5,6 7,8 9,10 11,12 13,14 15,16 17,18 > 18. Tetralogy of Fallot. Complex Congenital Heart Disease.

Systemic-Pulmonary Shunts in Neonates and Infants Using Microporous Expanded Polytetrduoroethylene: Immediate and Late Results

Anatomy & Physiology

Debate in Management of native COA; Balloon Versus Surgery

Pediatric Echocardiography Examination Content Outline

SURGICAL TREATMENT AND OUTCOME OF CONGENITAL HEART DISEASE

Congenital Heart Disease: Physiology and Common Defects

Balloon Valvuloplasty Through the Right Ventricle: Another Treatment of Pulmonary Atresia With Intact Ventricular Septum

Notes by Sandra Dankwa 2009 HF- Heart Failure DS- Down Syndrome IE- Infective Endocarditis ET- Exercise Tolerance. Small VSD Symptoms -asymptomatic

Surgical options for tetralogy of Fallot

Index. cardiology.theclinics.com. Note: Page numbers of article titles are in boldface type.

Cardiac Catheterization Cases Primary Cardiac Diagnoses Facility 12 month period from to PRIMARY DIAGNOSES (one per patient)

Adult Congenital Heart Disease: What All Echocardiographers Should Know Sharon L. Roble, MD, FACC Echo Hawaii 2016

For Personal Use. Copyright HMP 2013

Chapter 2 Cardiac Interpretation of Pediatric Chest X-Ray

Children with Single Ventricle Physiology: The Possibilities

Introduction. Pediatric Cardiology. General Appearance. Tools of Assessment. Auscultation. Vital Signs

The Chest X-ray for Cardiologists

CARDIAC INTERVENTIONS IN PEDIATRIC CARDIOLOGY: THE FUTURE

Patient guide: pfm Nit-Occlud PDA coil occlusion system. Catheter occlusion of. Patent Ductus Arteriosus. with the

HISTORY. Question: What type of heart disease is suggested by this history? CHIEF COMPLAINT: Decreasing exercise tolerance.

Case Report Computed Tomography Angiography Successfully Used to Diagnose Postoperative Systemic-Pulmonary Artery Shunt Narrowing

Transcatheter closure of the patent ductus arteriosus using the new Amplatzer duct occluder: Initial clinical applications in children

Coarctation of the aorta

Congenital Heart Disease

Neonatal Single Ventricle Heart Disease Recognition, Management, Counseling

CYANOTIC CONGENITAL HEART DISEASES. PRESENTER: DR. Myra M. Koech Pediatric cardiologist MTRH/MU

DIAGNOSIS, MANAGEMENT AND OUTCOME OF HEART DISEASE IN SUDANESE PATIENTS

In 1980, Bex and associates 1 first introduced the initial

Hybrid Muscular VSD Closure in Small Weight Children

Case Report. Stent Placement in a Neonate with Sano Modification of the Norwood using Semi-Elective Extracorporeal Membrane Oxygenation.

September 26, 2012 Philip Stockwell, MD Lifespan CVI Assistant Professor of Medicine (Clinical)

IMAGES. in PAEDIATRIC CARDIOLOGY

Case 47 Clinical Presentation

Pattern of Congenital Heart Disease A Hospital-Based Study *Sadiq Mohammed Al-Hamash MBChB, FICMS

CMS Limitations Guide - Radiology Services

IMAGES. in PAEDIATRIC CARDIOLOGY. Abstract

Index. interventional.theclinics.com. Note: Page numbers of article titles are in boldface type.

IMAGES. in PAEDIATRIC CARDIOLOGY

Critical Heart Disease in the Newborn. What you need to know

Isolated major aortopulmonary collateral as the sole pulmonary blood supply to an entire lung segment

By Dickens ATURWANAHO & ORIBA DAN LANGOYA MAKchs, MBchB CONGENTAL HEART DISEASE

PATENT DUCTUS ARTERIOSUS (PDA)

Slide 1. Slide 2. Slide 3 CONGENITAL HEART DISEASE. Papworth Hospital NHS Trust INTRODUCTION. Jakub Kadlec/Catherine Sudarshan INTRODUCTION

Cardiac CT in Infants with Congenital heart disease Sunrise Session. LaDonna Malone, MD May 17, 2018

Role of Balloons and Stents in Congenital Heart Disease

Fetal Tetralogy of Fallot

The goal of the hybrid approach for hypoplastic left heart

Survival Rates of Children with Congenital Heart Disease continue to improve.

Should Ductal Stent Implantation be Considered for All Newborn Infants with Reduced Pulmonary Blood Flow? Cons

"Lecture Index. 1) Heart Progenitors. 2) Cardiac Tube Formation. 3) Valvulogenesis and Chamber Formation. 4) Epicardium Development.

Hybrid Stage I Palliation / Bilateral PAB

How to Recognize a Suspected Cardiac Defect in the Neonate

CARDIAC CATHETERIZATION IN GROWN-UP PATIENTS WITH CONGENITAL HEART DISEASES INDICATIONS AND COMPLICATIONS

Approach to a baby with cyanosis

Structural heart disease in the newborn

Hemodynamic assessment after palliative surgery

MEDICAL SCIENCES Vol.I -Adult Congenital Heart Disease: A Challenging Population - Khalid Aly Sorour

Heart and Lungs. LUNG Coronal section demonstrates relationship of pulmonary parenchyma to heart and chest wall.

Paediatrics Revision Session Cardiology. Emma Walker 7 th May 2016

Multiple transcatheter ınterventions in the same session in congenital cardiopathies

Glenn Shunts Revisited

Transposition of the Great Arteries Preoperative Diagnostic Considerations. John Simpson Evelina Children s Hospital London, UK

List of Videos. Video 1.1

Outline. Congenital Heart Disease. Special Considerations for Special Populations: Congenital Heart Disease

R early primary complete repair in many patients with

Introduction. Study Design. Background. Operative Procedure-I

INTEGRATING ECHOCARDIOGRAPHY WITH CATHETER INTERVENTIONS FOR CONGENITAL HEART DISEASE. Krishna Kumar SevenHills Hospital, Mumbai, India

Transcription:

The Turkish Journal of Pediatrics 2007; 49: 413-417 Original Stent implantation into the patent ductus arteriosus in cyanotic congenital heart disease with duct-dependent or diminished pulmonary circulation Ahmet Çelebi, Yalım Yalçın, Abdullah Erdem, Cenap Zeybek, Celal Akdeniz Tuğçin Bora Polat Department of Pediatric Cardiology, Dr. Siyami Ersek Thoracic and Cardiovascular Surgery Center and Research Hospital, İstanbul, Turkey SUMMARY: Çelebi A, Yalçın Y, Erdem A, Zeybek C, Akdeniz C, Polat TB. Stent implantation into the patent ductus arteriosus in cyanotic congenital heart disease with duct-dependent or diminished pulmonary circulation. Turk J Pediatr 2007; 49: 413-417. We assessed the efficacy and safety of stent implantation into the ductus arteriosus in infants with cyanotic heart disease. Ten patients with duct-dependent or diminished pulmonary circulation underwent cardiac catheterization with the aim of stent implantation. Coronary stents of 3.5-4 mm in diameter were used and successfully implanted in eight. All patients in whom stent implantation was successful had adequate relief of their cyanosis and were discharged home. During a mean follow-up of 9.3 months (median 10 months), one patient had evidence of restenosis of the stent at five months. Re-dilatation of the stenosed stent was attempted but was unsuccessful and a modified left Blalock-Taussig shunt was placed surgically. Stent implantation of ductus arteriosus in neonates and infants with a ductdependent pulmonary circulation is an effective and safe palliative procedure. It may be an alternative to surgical systemic-pulmonary artery shunt in a select group of patients. Key words: ductus arteriosus, stent implantation, cyanotic heart disease. In neonates and infants with duct-dependent pulmonary circulation or diminished pulmonary blood flow, conventional emergency treatment consists of prostaglandin E1 (PGE1) infusion and subsequent creation of a surgical aortopulmonary shunt 1,2. Stent implantation of the arterial duct has been proposed as a non-surgical alternative to aorto-pulmonary shunt surgery 3,4. Results of early reports involving a small number of patients were not encouraging; however, more recent reports are promising 5-8. We assessed the efficacy and safety of ductal stenting in infants with duct-dependent pulmonary circulation. Material and Methods Between July 2004 and August 2005, stent implantations into the patent ductus arteriosus (PDA) were attempted in 10 infants with ductdependent or severely diminished pulmonary circulation after parental consent was obtained. Diagnosis and clinical properties of patients are summarized in Table I. Cardiac catheterization was performed under deep sedation or general anesthesia. Right femoral artery and vein were cannulated with 4-5F sheath. Heparin bolus (100 IU/kg) was given after the introducer was inserted, and heparin drip (20 IU/kg/h) was continued for 24 hours in patients in whom stent was implanted successfully. Aortic arch angiography in 90 lateral positions in all and 40 right anterior-oblique position in some patients were obtained to show anatomy and size of the ducts. PGE1 infusion was stopped, in those patients taking PGE1 infusion before the stent implantation, in order to induce ductal constriction and to prevent displacement of stent into pulmonary artery. All procedures were performed transarterially (retrograde)

414 Çelebi A, et al The Turkish Journal of Pediatrics October - December 2007 Table I. Main Diagnosis and Age of 10 Patients Who Underwent Catheterization for Stent Implantation Case Number Age (mo) Main diagnosis 1 1.45 Infundibular PS and severe RV hypoplasia 2 3 PA with intact ventricular septum 3 4 DORV, PA with VSD 4 14 PA with intact ventricular septum 5 4 C-TGA, VSD and severe PS 6 11 PA with VSD 7 1 C-TGA, PA with VSD 8 1 Critical pulmonary stenosis, ductus arteriosus 9 1.5 PA with VSD 10 1 Single inlet RV, DORV, severe PS PS: Pulmonary stenosis. RV: Right ventricle. PA: Pulmonary atresia. DORV: Double outlet right ventricle. VSD: Ventricular septal defect. C-TGA: Corrected transposition of great arteries. except one. In a patient with pulmonary atresia and intact ventricular septum, the stent was implanted transvenously after transcatheter guide-wire perforation and balloon dilatation of the pulmonary valve had been performed one week before. A 0.014 inch floppy tipped extrastiff guide-wire was placed either antegrade from the pulmonary artery into the descending aorta or retrograde from the aorta to pulmonary artery through the ductus. Standard coronary stents (OCCAM and EXOS PTCA stent) premounted on low-profile balloon dilatation catheters were used and placed into the ductus over the guide-wire. In all patients, special care was given to align the pulmonary end of ductus and to use a single stent to cover the complete length of the duct when possible. Therefore, a stent length slightly longer than ductus length was used. The median ductus length was 13.5 mm, and the median stent length was 16 mm (Table II). After stent implantation, control angiography was performed to determine stent position and to decide the necessity of additional stents (Figs. 1a, 1b, 1c). Cefazolin was given for 24 hours divided in three doses. All patients were discharged home on acetylsalicylic acid treatment (3 mg/kg/day). 1a 1b 1c Fig. 1. (1a) 90 lateral aortic angiogram performed to determine ductus morphology and to measure ductus length; (1b) shows fully expanded stent in the patent ductus arteriosus, with the balloon and wire still in place; and (1c) is post-stent angiogram demonstrating final stent position after deployment and unrestricted blood flow to the pulmonary artery. Case Number Method Table II. Stent Characteristics and Outcomes in 8 Patients with Successful Stent Implantation Intervention Ductus Length Stent Diameter Stent Length Saturation 1 Saturation 2 Follow-up Duration (month) Saturation 3 1 retrograde 8 3.5 11 55 82 12 80 2 antegrade 13 3.5 14 65 94 13 98 3 retrograde 12 4 16 60 92 5* 69 4 retrograde 14 4 16 42 86 12 83 5 retrograde 14 4 16 68 86 10 69 6 retrograde 20 4 20 62 84 10 71 7 retrograde 14 4 16 67 85 8 78 8 retrograde 12 3.5 13 65 85 4 98 1 : Before stent implantation. 2 : After stent implantation. 3 : During the last follow-up. *Surgical shunt after re-stenting.

Volume 49 Number 4 Stent Implantation into PDA 415 Every patient was followed up regularly for clinical evaluation, measurement of pulse oximetry saturation and echocardiographic examination at the 1 st, 3 rd, and 6 th months after the stent implantation. The mean oxygen saturations before and after stent implantations were compared with paired t test, and p<0.05 was accepted to be statistically significant. Results Results are summarized in Table II. Ductal stent implantations were successful in eight patients. In two patients with pulmonary atresia and intact ventricular septum, perforation and balloon dilatation of the atretic pulmonary valve were performed in addition to ductal stent implantation before or after. One of the patients, in whom intervention of the stent implantation was unsuccessful, had a vertical and tortuous PDA with a diagnosis of pulmonary atresia and ventricular septal defect (tetralogy of Fallot type; Case 9). We could not advance the stent-mounted balloon catheter through the PDA even though the guide-wire was manipulated in to the pulmonary artery in this patient. The other patient also had a vertical and tortuous PDA with severe narrowing at the pulmonary artery end (Case 10). During the attempts to cross the duct with a catheter over a guide-wire placed in to the pulmonary artery, spasm and complete obliteration of the ductus occurred. Even though intravenous PGE1 infusions were performed, neither reopened. Both patients had an emergency surgical aorto-pulmonary shunt; one patient survived and the other died. The median age at the time of the interventions was 3.5 months (range 1-14 months). The body weight ranged from 3 to 9 kg, with a median of 5.4 kg. Aortic oxygen saturations increased from median 63.5% to median 85.5% after stent implantation. Mean arterial oxygen saturation before stent implantations was 60.5±8.5% (42-68%) and increased to 86.7±4.1% (82-94%). The mean difference before and after stent implantations was found to be 26.2±8.8%, which was statistically significant (p<0.0001). The mean catheterization time ranged between 30 to 75 minutes, with a median of 42 minutes. Median fluoroscopy time was 14 minutes. Two patients were intubated and stayed on the ventilator for two days and were discharged to the pediatric floor on the third day. The median hospitalization time was five days. There were no procedure- related major complications. During a mean follow-up of 9.3 months, there was a significant reduction in pulse oxygen saturation in only one case. Re-dilatation of the stenosed stent was attempted in this patient. Since stent re-dilatation was not effective, re-stenting was performed, but stent kinking in the second stent occurred and a modified left Blalock-Taussig (BT) shunt was placed surgically. There was no significant decrease in oxygen saturations and all stents were patent without stenosis in the other patients (Table II). Discussion Neonates or infants with a duct-dependent pulmonary circulation or severely decreased pulmonary blood flow are usually treated by a surgical systemic to pulmonary artery shunt 1,2. Infusion of PGE1 has been life-saving in emergency conditions until the patient undergoes surgery, but it has disadvantages of peripheral vasodilatation, hypotension, hyperpyrexia and apnea 2. Compared with long-term PGE1 infusions, early duct stenting significantly shortens hospitalizations and reduces treatment costs 9. On the other hand, the disadvantages of surgical shunts are thoracotomy scar, adhesion and complications such as chylothorax, and phrenic and vagal nerve injury 6,7,9-11. Surgically created shunts may also cause distortion and stenosis of the shunted pulmonary artery or differential growth of the pulmonary arteries. Many of those disadvantages of the shunt operation can be avoided by securing pulmonary blood flow by stent implantation into the arterial duct. Stenting also enables equalized pulmonary blood flow, which may induce pulmonary arterial growth without causing distorsion or stenosis 6,10,11. The stenting procedure is well tolerated in premature and small infants 6,7,9. Without stent implantation, such patients would require prolonged PGE1 infusion or would be operated with high mortality and morbidity 11. Ductal stenting in such patients not only relieves cyanosis adequately but also induces growth of the pulmonary vasculature.

416 Çelebi A, et al The Turkish Journal of Pediatrics October - December 2007 Animal studies and previous reports showed optimum stent length must be a few millimeters longer than ductal length. The full length of the ductus is to be covered with stent, but at least the pulmonary side of the ductus must be covered since unstented segments of the PDA have a propensity for constriction 6,9. In all patients, special care was given to align the pulmonary end of the ductus and to use a single stent to cover the complete length of the duct. A stent length slightly longer than ductus length was used in our cases. The median ductus length was 13.5 mm, and the median stent length was 16 mm. Modified BT shunts of 3 to 5 mm in diameter are usually preferred by surgeons in neonates and infants. It has been reported that many neonates with stent diameter of 4.0 mm initially had excessive pulmonary flow. Since the PDA diameter is usually smaller than the modified BT shunts, it is reasonable to use a stent of 3.5 mm or less for neonates and 4 mm or greater for infants 7,8. However, when smaller stents are used, the risk of intimal proliferation and narrowing of the stent may be increased. In three patients, 3.5 mm, and in five patients, 4 mm stents were implanted. Only one of our cases (Case 2) needed treatment for increased pulmonary blood flow. This patient was three months old and diagnosed with pulmonary atresia and intact ventricular septum. After the initial guide-wire perforation and balloon valvuloplasty of the pulmonary valve, the patient continued to require PGE1 perfusion, and although a 3.5 mm stent was placed into the PDA, since the right ventricle compliance improved, the antegrade flow increased and the patient needed anti-congestive treatment. The absolute contraindication to stenting of the ductus is the presence of branch pulmonary artery stenosis 7. In a certain group of patients, constricted ductus arteriosus may cause branch pulmonary artery stenosis at the site of its insertion. Before the stent implantation, all patients should be evaluated for branch pulmonary artery stenosis. None of our cases had such a problem. The structure of the ductus arteriosus is unique when compared to other vascular structures. The media layer of the ductus is composed primarily of muscular fiber and the intimal layer is thicker than other vessels 12. These properties of the ductus theoretically may cause fatal ductal spasm. Even after initial successful stent implantation, intimal proliferation may cause early ductal stenosis 12. Although acute ductal obstruction and major complications leading to death are rare, intimal proliferation and slowly progressive stent stenosis are the major limiting factors 6,12. In such patients, it is still possible to re-dilate and/or implant a second stent into the narrowed ductus 6,13. Drug eluting stents or covered stents also have been proposed for preventing restenosis in adults. Studies evaluating efficacy of ductal stenting using such stents have not yet been done. Only one of our cases presented decreasing oxygen saturations at five months, which we considered as due to intimal proliferation. Our experience with a limited number of patients suggests that PDA stenting is a safe and effective procedure to secure pulmonary blood flow. With improved stent design and extended experience in implantation techniques, stenting of the ductus arteriosus in duct-dependent pulmonary circulation could be an attractive alternative, in a select group of patients, to the gold standard surgical creation of an aorto-pulmonary shunt. REFERENCES 1. Blalock A, Taussig H. The surgical treatment of malformations of the heart in which there is pulmonary stenosis or pulmonary atresia. JAMA 1945; 128: 189-192. 2. Neutze JM, Starling MB, Elliott RB, Barratt-Boyes BG. Palliation of cyanotic congenital heart disease in infancy with E-type prostaglandins. Circulation 1977; 55: 238-241. 3. Joe JY, Olley PM. A novel method to maintain ductus arteriosus patency. J Am Coll Cardiol 1991; 18: 837-841. 4. Gibbs JL, Rothman MT, Rees MR, et al. Stenting of the arterial duct: a new approach to palliation for pulmonary atresia. Br Heart J 1992; 67: 240-245. 5. Gibbs JL, Uzun O, Blackburn ME, et al. Fate of the stented arterial duct. Circulation 1999; 99: 2621-2625. 6. Schneider M, Zartner P, Sidiropoulos A, et al. Stent implantation of the arterial duct in newborns with duct-dependent circulation. Eur Heart J 1998; 19: 1401-1409. 7. Alwi M, Choo KK, Latiff HA, et al. Initial results and medium-term follow-up of stent implantation of patent ductus arteriosus in duct-dependent pulmonary circulation. J Am Coll Cardiol 2004; 44: 438-445. 8. Michel-Behnke I, Akintuerk H, Thul J, et al. Stent implantation in the ductus arteriosus for pulmonary blood supply in congenital heart disease. Catheter Cardiovasc Interv 2004; 61: 242-252.

Volume 49 Number 4 Stent Implantation into PDA 417 9. Gewillig M, Boshoff DE, Dens J, et al. Stenting the neonatal arterial duct in duct-dependent pulmonary circulation: new techniques, better results. J Am Coll Cardiol 2004; 43: 107-112. 10. Lamberti JJ, Carlisle J, Waldman JD, et al. Systemicpulmonary shunts in infants and children. Early and late results. J Thorac Cardiovasc Surg 1984; 88: 76-81. 11. Fermanis GG, Ekangaki AK, Salmon AP, et al. Twelve year experience with the modified Blalock-Taussig shunt in neonates. Eur J Cardiothorac Surg 1992; 6: 586-589. 12. Carlos ER, Leonard LB. Stenting the ductus arteriosus a Wanna-Be Blalock-Taussig. Circulation 1999; 99: 2608-2609. 13. Duke C, Rosenthal E, Qureshi SA. The efficacy and safety of stent redilatation in congenital heart disease. Heart 2003; 89: 905-912.