Cite this article as:

Similar documents
My Choice For Percutaneous Mitral Valve Replacement. Jose Luis Navia, MD.

Outline 9/17/2016. Advances in Percutaneous Mitral Valve Repair and Replacement. Scope of the Problem and Guidelines

APOLLO TMVR Trial Update: Case Presentation

Cite this article as:

Update on a Tethered Transapical Device for TMVR Vinay Badhwar, MD

Transcatheter Mitral Valve Replacement How Close Are We?

Next Generation Therapies: Aortic, Mitral and Beyond

Percutaneous mitral valve repair/replacement. Jan Van der Heyden MD, PhD St.Antonius Hospital Nieuwegein

Portico (St. Jude Medical Inc, St.

PERCUTANEOUS MITRAL VALVE THERAPIES 13 TH ANNUAL CARDIAC, VASCULAR AND STROKE CARE CONFERENCE PIEDMONT ATHENS REGIONAL

Major advancements have been made in transcatheter

Edwards Transcatheter AVR: Have the Outcomes Changed after CE Approval?

(Ann Thorac Surg 2008;85:845 53)

Percutaneous Mitral Valve Repair

William A. Gray MD System Chief of Cardiovascular Services, Main Line Health President, Lankenau Heart Institute Wynnewood, Pennsylvania USA

NeoChord Mitral Valve Repair. Department of Cardiac, Thoracic and Vascular Sciences University of Padua, Italy

Early Experience of Transcatheter Mitral Valve Replacement Results from the Intrepid Global Pilot Study

Multicentre clinical study evaluating a novel resheatable self-expanding transcatheter aortic valve system

TAVR: Echo Measurements Pre, Post And Intra Procedure

Percutaneous Valve Interventions. Percutaneous Valve Interventions

TAVI EN INSUFICIENCIA AORTICA

Percutaneous mitral annuloplasty. Francesco Maisano MD, FESC San Raffaele Hospital Milano, Italy

Professor and Chief, Division of Cardiac Surgery Chief Medical Officer, Harpoon Medical. The Houston Aortic Symposium February 23-25, 2017

TREATMENT OF MITRAL REGURGITATION RAJA NAZIR FACC

Mitral regurgitation (MR) is the most common

Mitral Programme Update

Revolutionizing how advanced heart disease is treated. Alexei Marko, CEO Chris Clark, CFO November 2014

New Cardiovascular Devices and Interventions: Non-Contrast MRI for TAVR Abhishek Chaturvedi Assistant Professor. Cardiothoracic Radiology

Percutaneous Mitral Valve Repair: What Can We Treat and What Should We Treat

Advanced Mitral Valve Therapies

1-YEAR OUTCOMES FROM JOHN WEBB, MD

TAVR SPRING 2017 The evolution of TAVR

Transcatheter Mitral Valve Implantation: Techniques and Early Clinical Outcomes. Dr. T. Modine MD, PhD, MBA Heart team CHRU de Lille

LivaNova Investor Day

Repair or Replacement

Transcatheter Aortic Valve Replacement with Evolut-R

King s Research Portal

Transcatheter Mitral Valve for fmr: The Era of Too Many Options

Introducing the COAPT Trial

Interventional procedures guidance Published: 26 September 2014 nice.org.uk/guidance/ipg504

8/31/2016. Mitraclip in Matthew Johnson, MD

Transcatheter aortic valve implantation for severe aortic valve stenosis with the ACURATE neo2 valve system: 30-day safety and performance outcomes

Transcatheter valve-in-valve implantation for degenerated surgical bioprostheses

Mitral Valve Disease, When to Intervene

CIPG Transcatheter Aortic Valve Replacement- When Is Less, More?

TRANSCATHETER MITRAL VALVE IMPLANTATION FOR SEVERE MITRAL REGURGITATION: THE TENDYNE GLOBAL FEASIBILITY TRIAL 1 YEAR OUTCOMES

Transcatheter Mitral Valve Interventions: Clinical Indications. Didier TCHETCHE, MD. Clinique Pasteur, Toulouse, France.

Update on Transcatheter Mitral Valve Repair and Replacment

2 Brigham and Women s Hospital, Boston, MA.

Transcatheter Aortic Valve Replacement: Current and Future Devices: How do They Work, Eligibility, Review of Data

Chapter 24: Diagnostic workup and evaluation: eligibility, risk assessment, FDA guidelines Ashwin Nathan, MD, Saif Anwaruddin, MD, FACC Penn Medicine

DISCLOSURE. Mitral ViV: why? Mitral Valve- in- Valve: Procedural Image Guidance with TEE, a Must Have or Nice to Have? UW Medicine NONE.

Aortic valve implantation using the femoral and apical access: a single center experience.

First Transfemoral Aortic Valve Implantation In Bulgaria - Crossing The Valve With The Device Is Not Always

3D Printing & Echocardiography

Outline. EuroScore II. Society of Thoracic Surgeons Score. EuroScore II

2/28/2010. Speakers s name: Paul Chiam. I have the following potential conflicts of interest to report: NONE. Antegrade transvenous transseptal route

Transapical Transcatheter Aortic Valve Implantation in the Presence of a Mitral Prosthesis

When Does 3D Echo Make A Difference?

PVL Assessment. Is paravalvular regurgitation after TAVR still an important consideration in 2018?

Get Ready for Percutaneous Mitral Valve Approaches

MITRAL (Mitral Implantation of TRAnscatheter valves)

30-day Outcomes of The CENTERA Trial a New Self-Expanding Transcatheter Heart Valve. Didier Tchétché, MD On Behalf of the CENTERA Investigators

TAVI- Is Stroke Risk the Achilles Heel of Percutaneous Aortic Valve Repair?

Bioprosthetic Mitral Valve Dysfunction: Innovation and Evolution of a New Therapeutic Technique

3D Printing & Echocardiography

Transcatheter Mitral Valve Replacement. Lutter G, Lozonschi L

Percutaneous Valve in Native With and Without Mitral Valve Calcification: When To Go Hybrid

Revolutionizing how advanced heart disease is treated

Management of Difficult Aortic Root, Old and New solutions

Valve Disease in Patients With Heart Failure TAVI or Surgery? Miguel Sousa Uva Hospital Cruz Vermelha Lisbon, Portugal

CoreValve Evolut R Technology review and Clinical Results. Paul TL Chiam

Severity of AS Degree of AV calcification (? Bicuspid AV), annulus size, & aortic root

CLIP ΜΙΤΡΟΕΙ ΟΥΣ: ΠΟΥ ΒΡΙΣΚΟΜΑΣΤΕ;

Transcatheter Aortic Valve Implantation. SSVQ November 23, 2012 Centre Mont-Royal 15:40

Valve Replacement without a Scalpel Transcatheter Aortic Valve Replacement (TAVR) Charles T. Klodell, M.D.

Ian T. Meredith AM. MBBS, PhD, FRACP, FCSANZ, FACC, FAPSIC. Monash HEART, Monash Health & Monash University Melbourne, Australia

Really Less-Invasive Trans-apical Beating Heart Mitral Valve Repair: Which Patients?

Alec Vahanian,FESC, FRCP (Edin.) Bichat Hospital University Paris VII, Paris, France

An Update on the Edwards TAVR Results. Zvonimir Krajcer, MD Director, Peripheral Intervention Texas Heart Institute at St.

Percutaneous Therapy for Calcific Mitral Valve Disease

Index. B B-type natriuretic peptide (BNP), 76

Late secondary TR after left sided heart disease correction: is it predictibale and preventable

Critical role of multi-modality planning in Transcatheter Mitral Valve Replacement

Nouvelles indications/ Nouvelles valves

Understanding the guidelines for Interventions in MR. Ali AlMasood

Accepted Manuscript. MAC: Mitral Annular Calcification or a Modern Approach to Concept learning in surgery

Transcatheter Aortic Valve Replacement With the St. Jude Medical Portico Valve

Transcatheter Aortic Valve Replacement

Mitral Regurgitation

Prosthesis-Patient Mismatch or Prosthetic Valve Stenosis?

Disclosure Statement of Financial Interest Saibal Kar, MD, FACC

NEXT-GENERATION TAVR. A look at the future of percutaneous valve replacement.

Echo Assessment Pre-TAVI

Transcatheter Mitral Valve Repair: today and tomorrow Sponsored by Abbott. Chairperson: M. Haude Panellists: A. Al Nooryani, M.

Aortic Valve Practice Guidelines: What Has Changed and What You Need to Know

Subacute left ventricular outflow tract obstruction after transapical closure of a mitral paravalvular leak in the region of the aortomitral curtain

Imaging in TAVI. Jeroen J Bax Dept of Cardiology Leiden Univ Medical Center The Netherlands Davos, feb 2013

Procedural Guidance of TAVR: How to Assure it Goes Right and What to Do If It Doesn t

Successful Percutaneous Closure of Mitral Bioprosthetic Paravalvular Leak Using Figulla ASD Occluder

Transcription:

doi: 10.21037/acs.2018.09.05 Cite this article as: Cheung A. Early experience of TIARA transcatheter mitral valve replacement system.. doi: 10.21037/acs.2018.09.05 This is a PDF file of an edited manuscript that has been accepted for publication. As a service to our customers we are providing this Online First version of the manuscript. The manuscript has undergone copyediting, typesetting, and review of the resulting proof before it is published in its final form. Please note that during the production process errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.

Perspective Early experience of TIARA transcatheter mitral valve replacement system Anson Cheung Division of Cardiothoracic Surgery, St. Paul s Hospital, University of British Columbia, Vancouver, British Columbia, Canada Correspondence to: Anson Cheung, MD. 1080 Burrard Street, Vancouver, BC V6Z 1Y6, Canada. Email: acheung@providencehealth.bc.ca. Mitral regurgitation (MR) is a common valvular disorder that can result in congestive heart failure and cardiovascular death. Patient suffering from this condition are frequently not referred and thus the condition is under-treated. Surgery remains the gold standard treatment for mitral valve disease, however, catheter based mitral valve interventions, including repair and replacement, are being employed to treat patients who are deemed high or prohibitive risk for conventional surgery. TIARA is one of the many newly developed transcatheter mitral valve replacement (TMVR) systems that may address this unmet need. Keywords: Mitral valve; transcatheter; replacement Submitted Aug 29, 2018. Accepted for publication Sep 14, 2018. doi: 10.21037/acs.2018.09.05 View this article at: http://dx.doi.org/10.21037/acs.2018.09.05 TIARA transcatheter mitral valve replacement (TMVR) system The TIARA TMVR (Neovasc Inc., Richmond, BC, Canada) is a transapical access-based system that is designed to treat mitral regurgitation (MR). The TIARA valve prosthesis consists of a nitinol self-expanding frame that is saddle shaped to mimic the geometry of the native mitral annulus (Figure 1). Three bovine pericardial leaflets provide the coaptation function and a large atrial skirt seals the mitral inflow to prevent paravalvular leak (PVL). Device fixation is provided by radial expansion of the TIARA and axial anchorage is achieved with ventricular tabs. Two anterior tabs anchor the valve onto the fibrous aortomitral curtain and a single posterior tab lands behind the posterior mitral leaflet onto the muscular posterior shelf of the mitral annulus (1-3). At present, a 35 and 40 mm device are available to treat a wide range of annular dimension. Sizing is based on careful assessment of the mitral annular dimensions by contrast-enhanced multi-slice computer tomography (CT). TIARA valves are delivered by a sheathless system via the left ventricle (LV), a 36-French (Fr) for the 35 mm and 40 Fr for the larger valve. An atraumatic and self-dilating tip allows easy entry into the LV. Valve delivery, deployment and resheathing is achieved by a simple turn knob mechanism. Patient screening Identifying suitable candidates for TMVR therapy has been a challenge for all devices. Exclusion for potential TMVR therapy can be clinical, anatomical and/or device-specific. Extensive investigations include coronary angiogram, transthoracic and transesophageal echocardiography (TEE) and cardiac CT is performed in all patients. Patients with significant co-morbidities, poor ventricular function with a LVEF <20%, severe right ventricle dysfunction and irreversible pulmonary hypertension are deemed unsuitable. Echocardiographic eligibility criteria include severe symptomatic MR (stage D) by 2014 AHA/ACC Valvular Heart Disease Guidelines classification, as determined by Core Laboratory. Contrast-enhanced gated CT data acquisition of the entire cardiac cycle must be acquired to determine of dimensions of the mitral annulus, the presence of annular calcification, subvalvular complexes, the LV and left ventricular outflow tracts (LVOT). The risk for potential LVOT obstruction can be determined with simulated device implants and the anticipated residual neo-lvot crosssectional area can be calculated. Patients with a predicted

2 Cheung. TIARA TMVR Posterior anchor Atrial skirt Atrial skirt Anterior anchor Bovine pericardial leaflets Figure 1 The Neovasc TIARA valve prosthesis. Table 1 Sizing chart for the 35 and 40 mm TIARA valve Size (mm) Mitral annulus circumference (cm) Atrial height (cm) Annulus area (cm 2 ) A-P (mm) Distance C-C (mm) 35 9.3 11.0 5.0 6.5 9.0 26.5 30.0 31.0 35.0 40 11.0 12.5 5.0 9.0 12.0 30.0 34.0 35.0 40.0 neo-lvot area of 2.0 cm 2 at end-systole were considered eligible for TIARA. CT data including the entire rib cage was used to determine the optimal intercostal space for transapical access. Anatomical suitabilities are mainly assessed by echocardiography and cardiac CT. In addition to annular dimensions, cardiac CT provides invariable information for determining other anatomical details, such as LVOT dimension, angle and anatomical fit of the TIARA device (4). Common patient exclusions include poor LV function, excessive mitral annular dimensions, absence of posterior shelf and high risk of LVOT obstruction. Table 1 illustrates the sizing criteria for the two current devices. Case example and implant procedure A 80-year-old man with ischemic cardiomyopathy, previous myocardial infarction, coronary artery bypass grafting, peripheral vascular disease with repair of abdominal aortic aneurysm and chronic renal insufficiency on good medical therapy. This patient suffered from NYHA class III heart failure with an ejection fraction of 25% and severe functional MR. His STS and EuroSCORE II risk score for mitral valve replacement (MVR) were 8.4% and 28.4% respectively. The heart team s assessment deemed that the patient was at excessive risk for open MVR and not a suitable candidate for transcatheter leaflet plication therapy secondary to a retracted and short posterior MV leaflet. However, he was an excellent candidate for a 40 mm TIARA TMVR after careful screening (Figure 2A,B). The implant procedure was performed in a hybrid operating room with guidance from fluoroscopy and TEE. Close intra-procedural collaboration from all heart team members, with the presence of cardiac surgeon, interventional cardiologist and echocardiographer, is crucial to the success of the procedure. The ideal location of the left anterior mini-thoracotomy over LV puncture site is guided by pre-procedural CT imaging and surface ultrasound. Placement of two horizontal mattress pledgeted sutures provided hemostasis of the LV puncture site. Crossing of the MV is achieved with a soft J wire and is later exchanged to a 0.035-inch Amplatz Extra-Stiff wire (Boston Scientific Corp., Indianapolis, USA). Subvalvular entanglement was assessed and ruled out by TEE. The TIARA TMVR delivery system was inserted across the MV into the left atrium (LA), and subsequently, the atrial skirt of the TIARA system is delivered across the valve. Threedimensional TEE guidance is used to ensure anatomical alignment of D-shaped TIARA device to match the geometry of the MV annulus. Once aligned, the atrial skirt was seated onto the atrial MV annulus by withdrawal of the system ventricularly. Device resheathing, repositioning and retrieval can be

Annals of cardiothoracic surgery, 2018 3 A B Figure 2 Pre-procedural CT assessment of the mitral apparatus. (A) CT assessment of suitability for TIARA implant with measurements of annular dimensions; (B) simulated TIARA implantation with calculated neo-lvot area. CT, computer tomography; LVOT, left ventricular outflow tract. A B C D Figure 3 Procedural steps of a transapical TIARA implantation. (A) Unsheathing of atrial skirt; (B) TIARA rotation to align with the geometry of the native mitral annulus; (C) release of the two anterior anchoring tabs; (D) full deployment of the TIARA valve. performed up to this stage of procedure. The ventricular tabs and the ventricular skirt were then released with further unsheathing (Figure 3A,B,C,D). Cardiopulmonary bypass support was not necessary and hemodynamic stability was maintained throughout the procedure. Excellent device seating was achieved with a mean transvalvular gradient of 2 mmhg, absence of LVOT obstruction and no PVL (Figure 4). The patient did not require blood product

4 Cheung. TIARA TMVR Figure 4 Post implant echocardiogram demonstrated a well seated TIARA valve with no mitral regurgitation or paravalvular leak. transfusion, was extubated in the operating theatre and had an uneventful post-operative course. Clinical updates The first-in-human TIARA implantation was performed in 2014 by the team at St. Paul s Hospital, Vancouver, Canada (5). Many successful implantations have been conducted under compassionate access programs in Canada, Italy, Germany, Switzerland and Israel. The longest surviving patient from Canada has passed her 4-year anniversary with a well-seated, functioning prosthesis, with excellent hemodynamics and with minimal heart failure symptoms (NYHA class II). Currently, the TIARA TMVR programs include the TIARA-I Early Feasibility and the TIARA-II European CE Mark trials. The TIARA-I is a multinational, multicenter trial being conducted in Canada, the US and Belgium, with the primary objectives being to assess the 30-day safety outcomes in high-risk surgical patients suffering from severe MR. Secondary objectives include device performance, adverse events and clinical outcomes up to one year. The first enrollment and successful implantation was carried out in Belgium by Dr. Stefan Verhedye s team in 2014. The TIARA-I study is actively enrolling and anticipating full enrollment at the end of 2018. The TIARA-II CE Mark Trial is actively enrolling in Germany, Italy and the United Kingdom. Additional sites are being activated in Germany, Italy and Israel. Thus far, over 50 patients have been treated with the TIARA TMVR with 95% implant success rates with no intraoperative mortality reported. The 30-day mortality in this very high-risk cohort was at 8.5%. Conclusions Many patients with severe MR are not currently offered treatment. Transcatheter mitral therapy provides additional options for patients that are deemed at too high a risk for surgical correction. The TIARA TMVR system is a TMVR technology specifically designed to address this pathology. The transventricular implant procedure is straight-forward, reproducible and safe. Correction of MR is complete with excellent hemodynamics. Ongoing implantations in the TIARA-I and II clinical trials will further provide important clinical data for TMVR in the treatment of mitral insufficiency. Acknowledgements None. Footnote Conflicts of Interest: A Cheung is Consultant and proctor, Neovasc Inc., Principle investigation, Tiara-1 Feasibility Trial.

Annals of cardiothoracic surgery, 2018 5 References 1. De Backer O, Piazza N, Banai S, et al. Percutaneous transcatheter mitral valve replacement: an overview of devices in preclinical and early clinical evaluation. Circ Cardiovasc Interv 2014;7:400-9. 2. Banai S, Jolicoeur EM, Schwartz M, et al. Tiara: A Novel Catheter-Based Mitral Valve Bioprosthesis: Initial Experiments and Short-Term Pre-Clinical Results. J Am Coll Cardiol 2012;60:1430-1. 3. Banai S, Verheye S, Cheung A, et al. Transapical mitral implantation of the Tiara bioprosthesis: pre-clinical results. JACC Cardiovasc Interv 2014;7:154-62. 4. Blanke P, Naoum C, Dvir D, et al. Predicting LVOT Obstruction in Transcatheter Mitral Valve Implantation: Concept of the Neo-LVOT. JACC Cardiovasc Imaging 2017;10:482-5. 5. Cheung A, Webb J, Verheye S, et al. Short-term results of transapical transcatheter mitral valve implantation for mitral regurgitation. J Am Coll Cardiol 2014;64:1814-9. Cite this article as: Cheung A. Early experience of TIARA transcatheter mitral valve replacement system. Ann Cardiothorac Surg 2018. doi: 10.21037/acs.2018.09.05