Bioimpedance in medicine: Measuring hydration influence

Similar documents
Premium solution for your health

BODY SCAN REPORT YOUR RESULTS SAMPLE - BODY FAT - LEAN MUSCLE - TOTAL BODY WATER - EXTRA-CELLULAR WATER - INTRA-CELLULAR WATER - METABOLIC RATE

Body composition A tool for nutritional assessment

Development of Bio-impedance Analyzer (BIA) for Body Fat Calculation

InBody R20 Body composition Analyzer

Body composition. Body composition models Fluid-metabolism ECF. Body composition models Elemental. Body composition models Anatomic. Molnár Dénes.

InBody-the product of great technology Experience its speciality

BODY COMPOSITION: AN ANALYSIS BETWEEN THE FOOTBALLER AND THANG-TA PRACTITIONER OF MANIPUR

Body Composition Analyzer

Lighten-up your Child s Growth

Versatile application with advanced technology

RESULTS SHEET BREAKDOWN

Health Care & Human Care

Chapter 17: Body Composition Status and Assessment

For Convenient Use

Segmental Body Composition Assessment for Obese Japanese Adults by Single-Frequency Bioelectrical Impedance Analysis with 8-point Contact Electrodes

BODY MASS INDEX AND BODY FAT CONTENT IN ELITE ATHLETES. Abstract. Introduction. Volume 3, No. 2, 2011, UDC :572.

FAT MASS ESTIMATION BY BIOELECTRICAL IMPEDANCE ANALYSIS

Validation Study of Multi-Frequency Bioelectrical Impedance with Dual-Energy X-ray Absorptiometry Among Obese Patients

What Is Body Composition?

There are 4 user settings that store the memory of personal parameters for ease of continued use.

InBody 770. Preciseness and reliability of the InBody is proven by the world s top journals and scholars

BODY COMPOSITION COMPARISON: BIOELECTRIC IMPEDANCE ANALYSIS WITH DXA IN ADULT ATHLETES

Where BMI ends, seca the unique diagnostic and medical practices.

Design of Bodyfat Measurement System based on the Android Platform

QUANTUM. Body Composition Scale. 396lb x 0.2lb 180kg x 0.1kg

DOI: /HAS/AJHS/9.2/

Broadening Course YPHY0001 Practical Session II (October 11, 2006) Assessment of Body Fat

the path to fitness is right at your own feet

Understanding Body Composition

Physiology Department, Medical University of Lublin, Radziwiłłowska 11 Street, Lublin, Poland 2

Prediction of extracellular water and total body water by multifrequency bio-electrical impedance in a Southeast Asian population

Broadening Course YPHY0001 Practical Session III (March 19, 2008) Assessment of Body Fat

Competitor Series. Body Composition Analyzers

BC380. The New Standard in Body Composition Analysis BODY COMPOSITION ANALYZER

DIALYSIS OUTCOMES Quality Initiative

MEDICALSOFT. Innovative health & wellness screening systems for professional and personal use

Alexandra M. Johnstone a, Peter Faber b, Eileen R. Gibney c, Gerald E. Lobley a, R. James Stubbs a, Mario Siervo d, ORIGINAL ARTICLE

Module 2: Metabolic Syndrome & Sarcopenia. Lori Kennedy Inc & Beyond

PROFESSIONAL FITNESS & WELLBEING CATALOGUE

The Assessment of Body Composition in Health and Disease

BC310. Body Composition Analyzer. Medical Diagnostic Device

Diagnostics Assessment Report (DAR) - Comments

Fitness Nutrition Coach. Part IV - Assessing Nutritional Needs

ESPEN Congress Prague 2007

PEACE OF MIND PREDICTION EXPERIENCE ACCURACY MONITORING RELIABILITY

Effect of Physical Training on Body Composition in Moscow Adolescents

Professional body composition analysis: BODYSTAT I500. Touch Screen THE SCIENCE BEHIND CLINICAL BODY ASSESSMENT.

Artificial Neural Network: A New Approach for Prediction of Body Fat Percentage Using Anthropometry Data in Adult Females

See Your Body BetterTM

This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archiving.

Estimation of Pulse Arrival Time Using Impedance Plethysmogram from Body Composition Scales

Analysis of Body Compositions and Energy Expenditure of Sedentary Teaching Employees of SDAU, Gujarat, India

ESPEN Congress The Hague 2017

InBody 270. Timeless style, yet significant feature changes

Package. Your InBody package will include: *Additional accessories can be purchased at

The effect of a meal on measures of impedance and percent body fat estimated using contact-electrode bioelectrical impedance technology

Phase Angle What is it & why is it Important?

Yasushi Ohashi, MD, Takatoshi Otani, MD, Reibin Tai, MD, Yoshihide Tanaka, MD, Ken Sakai, MD, PhD, and Atsushi Aikawa, MD, PhD

Body Mass Index. The table below can be used to assess an adult s status BMI Status.

What is body composition?

Interpretation Guide. What you are made of? Find out with - Vital Body Scan NZ Ltd. Mobile Body Composition Analysis

Body Composition and Anthropometric Form

Table of Contents. Introduction. 1. Diverse Weighing scale models. 2. What to look for while buying a weighing scale. 3. Digital scale buying tips

Assessment of body composition of Sri Lankan Australian children using ethnic specific equations

1. Frequently asked questions

Evaluation of mu I ti-frequency biei m pedance analysis for the assessment of extracellular and total body water in surgical patients

The effect of intake of water on the final values of body composition parameters in active athletes using two different bioimpedance analyzers

Body Fat Monitor / Scale Model: UM-040/041 Instruction Manual

Citation for published version (APA): Haverkort, E. B. (2014). The value of nutritional assessment in major abdominal surgery

Validation of bioimpedance body composition assessment by TANITA BC-418 in 7 years-

Comparison of Bioelectrical Impedance Analysis with Dual Energy X-ray Absorptiometry in Obese Women. Abstract

MEDICALSOFT. Innovative health & wellness screening systems for professional and personal use

Relationship between body fat percentage and forced vital capacity in adults with normal body mass index

Professional body composition and nutrition analysis: BODYSTAT I500MDD. Touch Screen THE SCIENCE BEHIND CLINICAL BODY ASSESSMENT.

Modern Standard Reliable

BC ACCUNIQ BC310 Specifications. Body Composition Analyzer. Medical Diagnostic Device

Influence of acute consumption of caffeine vs. placebo over Bia-derived measurements of body composition: a randomized, double-blind, crossover design

Manipulating Pretesting Conditions for Measuring Body Composition Using the BodPod and Bioelectrical Impedance AN HONORS THESIS (HONR 499)

A CLINICAL OBSERVATION ON THE EFFECT OF COLLAGEN HYDROLYSATE (Calorad*) ON OVERWEIGHT AND OBESE INDIVIDUALS

Body Composition Assessment Scholars

BC720. Body Composition Analyzer. Medical Diagnostic Device

Evaluation of two foot-to-foot bioelectrical impedance analysers to assess body composition in overweight and obese adolescents

CHAPTER 9. Anthropometry and Body Composition

Instruction Manual BODY COMPOSITION ANALYZER DC-360. Please read this Instruction Manual carefully and keep it for future reference.

Bioelectrical impedance: effect of 3 identical meals on diurnal impedance variation and calculation of body composition 1,2

Effects of procedure, upright equilibrium time, sex and BMI on the precision of body. fluid measurements using bioelectrical impedance analysis.

MEASUREMENT OF BODY COMPOSITION BY IMPEDENCEMETRY NUTRITION CENTRES

Effects of Heat Exposure on Body Water Assessed using Single- Frequency Bioelectrical Impedance Analysis and Bioimpedance Spectroscopy

BC510. Body Composition Analyzer. Medical Diagnostic Device

Evaluation of body fat in fatter and leaner 10-y-old African American and white children: the Baton Rouge Children s Study 1 3

ORIGINAL COMMUNICATION

Body Fat % Body Water % Full Body Composition Analysis Segmental Body Composition Analysis

Development of Regression Equation for the Measurement of Visceral Fat Area using Bioimpedance Technique

Portable Healthcare Solution on the Go

BODY COMPOSITION ASSESSMENT WITH SEGMENTAL MULTIFREQUENCY BIOIMPEDANCE METHOD *

Proven and reliable performance Ergonomic design for efficient workflow The archetype of body composition test

Visualizing transplanted muscle flaps using minimally invasive multielectrode bioimpedance spectroscopy

Professional body composition and nutrition analysis: BODYSTAT I500MDD THE SCIENCE BEHIND CLINICAL BODY ASSESSMENT.

Transcription:

Journal of Physics: Conference Series Bioimpedance in medicine: Measuring hydration influence To cite this article: J Hlubik et al 0 J. Phys.: Conf. Ser. 0 View the article online for updates and enhancements. This content was downloaded from IP address... on //0 at :

Journal of Physics: Conference Series (0) 0 doi:./-///0 Bioimpedance in medicine: measuring hydration influence J Hlubik, P Hlubik, L Lhotska Gerstner Laboratory, Faculty of Electrical Engineering, Czech Technical University in Prague, Czech Republic Faculty of Military Health Sciences Hradec Králové, University of Defense, Czech Republic hlubikjan@post.cz Abstract. The aim of the paper is to present results of our ongoing research focused on the influence of body hydration on the body impedance measurements and also on the influence of the frequency used for the measurement. The question is why to measure human body composition and if these values have beneficial results. First goal of the work deals with a question of measuring human body composition. The performed measurements showed certain influence which must be verified by repeated experiments.. Introduction The most popular and publicly well-known are the studies using the Body Mass Index (BMI) as a single parameter indicating the degree of obesity (or slimness). However it cannot tell anything about the body composition. This parameter is very specific because it does not take into account human body composition. This fact means that 0cm, 0kg sports man and 0cm, 0kg lazy man can have the same BMI. The BMI is the same but just at glance we can tell who is healthier. Because of that body composition is very important, with values of body composition it is easier to predict and treat diseases connected with obesity. It is known that density of bones and quality of muscles influences the weight to a certain degree. That means that two persons having the same height and waist size might have relatively high difference in weight due to the differences in body composition. Thus, a method allowing measurement of more informative quantities is necessary in order to evaluate the amount of body fat more objectively and precisely. A method that would be able to measure important body composition more precisely and cheaper is needed. There are several methods to determine body composition such as DXA that is considered being the reference method. Despite all benefits, this method has also disadvantages. A practical limitation of DXA is exposure of the subject to ionizing radiation (< µsv). Another disadvantage is price of this method. Other methods are e.g.: W/H circumference, measurements with calipers and so on. The Body Impedance Analysis (BIA) represents one of the methods for classification of body composition. This method uses electrical current that passes through the body. This current is then measured and from these values there are calculated parts of body composition such as FFM (fat free mass), TBW (total body water), ICW (intracellular water), ECW (extracellular water), fat% and so on. At present the most frequently used frequency for elementary devices is 0 khz. The question is c 0 Ltd

Journal of Physics: Conference Series (0) 0 doi:./-///0 whether this frequency is correct. Or would be another one better? BIA can be performed on various devices. Starting with basic single frequency bipedal devices and ending with high end devices that are using multi frequency tetra polar electrodes system. It is crucial to know which value is needed and due to this choose right device. For example, for basic examination basic device is enough, but these devices could be often biased. So it is crucial to use proper device. This is very true for obesity as obesity does not refer to excessive body weight but it refers to the condition in which the individual has an excessive amount of body fat. Many laboratory and field assessment techniques exist for estimating a person's body composition. Obesity is characterized by Body Mass Index (BMI) > 0kg/m² and by body fat increase. It is possible to use a number of methods including the measurement of body impedance for observing the body fat mass. Body impedance depends on body composition, i.e. on the amount of water in individual tissues. Many of the studies [,] performing the BIA for various purposes (e.g. relevance to diagnosing metabolic disorders, cardiovascular risk, assessment of degree of obesity, etc.) usually do not mention level of hydration of examined subjects and frequency used during the measurement. This led us to formulation of the following three goals of our study.. Goals The first goal is to find out what effect liquid consumption has to the measurement and to which degree the measured values are influenced by level of hydration. Impedance has the highest value in fat tissue that contains only 0 % of water. In fat-free mass that contains 0 % of water the values are lower. For the measurement under standard conditions it is assumed that the body is within normal hydration ranges. If a person is dehydrated then the amount of fat tissue can be overestimated. The second goal is to identify importance of frequency on measuring. The reason is that the recently developed devices for clinical purposes allow multi-frequency measurement. It is assumed that it may lead to more precise measurements of specific parts of the body, and that each frequency can have specific importance. The third goal of this work was to compare two devices InBody 0 and Tanita MC-0 MA in extreme body weight. We consider that every device uses specific software (equations) for calculating body parameters.. Methods For the first measurement there was taken a group of individuals. They received, l of water to find out the importance of body hydration. Measurements were taken before drinking, 0 minutes after drinking, then 0 minutes later and the last measurement was taken before going to toilet. In the second experiment the group of individuals was measured. Two devices InBody 0 and Tanita MC-0 MA were used. Tanita MC-0 MA device is able to measure on frequencies khz, 0 khz, 0 khz and 00 khz. InBody 0 device is able to measure on frequencies khz, khz, 0 khz, 0 khz, 00 khz and MHz. We used for comparison only four frequencies available on both devices. We studied changes of impedance values in dependence on changing frequency. An individual with BMI > kg/m was measured to compare values of these two devices in extreme body composition conditions.

Journal of Physics: Conference Series (0) 0 doi:./-///0. Results Quantitative results are shown in Table, Table, and Figure. 00 0 0 0 0 00 0 Table, : Values of impedance (Ω) during hydration measurements on both devices Tanita Meas Meas Meas InBody Meas Meas Meas 0, 0,,,,,,,,,,0,,,0,,,,,,, 0,,,, 0,, 0,,, 0,,,,,, 0,,,,,,, 0,,,,,,,,,,,,,,,,,, 0,,,,,,,,, 00,,,,,,,,,,,,,,,0,,,,0, sd,,0, sd,00 0,,0 Figure : History of impedance (Ω). Progress of impedance during hydration frequency 0 khz - Tanita Measurement Průměr TBW (%) Figure : History of TBW (kg). TBW (kg) - Tanita Measurement Measurement Measurement On table, and figure there is shown progress of impedance during hydration. From these outcomes it is obviously seen that consumption of water is noticeable but it depends on subject. And it also depends on each used device. From our research it is shown that in general consuming. l of mineral water does not have so high importance, but only when we use comparable devices. In figure there is shown progress of TBW during hydration. Next goal was following progress of impedance during change of frequency. These trends are shown in figure. Figure : Progress of impedance Tanita and Inbody. Progress of impedance - Tanita Progress of impedance - InBody 0 0 0 0 0 0 0 0 0 0 00 Frequency khz 00 0 00 0 00 0 0 0 00 In this figure there is shown progress of impedance dependent on frequency on both devices. The dependence of impedance on frequency was very significant. However, further studies are needed to confirm which frequency is best for measurements or if all four frequencies are necessary. The last goal was to compare two devices to find out which device is more suitable for measuring and whether there is a significant difference in these devices. We used extreme conditions. The result of this comparison is shown in figure. Frequency khz

Journal of Physics: Conference Series (0) 0 doi:./-///0 Figure : Comparison of devices segmental impedances on 0 khz. Obez patient - device comparison: Impedance 00,0,,0,0 0,0,,0, Impadance [Ω] 0,0, InBody Tanita,0, 0,0,0,, 0,0 RH LH RL LL From figure it is obvious that there is a difference between these two devices but the difference is not so significant. So it is possible to replace these devices and outcome values should not differ so much.. Conclusions The outcome of this study is that these devices are comparable for measurements of extreme conditions. Correlation of impedances and other body composition values were very high. The dependence of impedance on frequency was very significant. Therefore a deep analysis is necessary which frequencies to use. Third outcome was that hydration has not significant influence on changes of body impedance. Work still continues to prove whether hydration of an individual has certain influence on body composition, such as FFM, TBW. Acknowledgement Research described in the paper has been supported by the research program No. MSM 000 "Transdisciplinary Research in Biomedical Engineering II" of the CTU in Prague. References [] Alcibiades Lara Lafargue, Luis Bergues Cabrales, and Ricardo Morales Larramendi 00 Bioelectrical Parameters of the Whole Human Body Obtained Through Bioelectrical Impedance Analysis. Bioelectromagnetics :0- [] Ursula G. Kylea, Ingvar Bosaeusb, Antonio D. De Lorenzoc, Paul Deurenbergd, Marinos Eliae, Jose Manuel Gomezf, Berit Lilienthal Heitmanng, Luisa Kent-Smithh, Jean-Claude Melchiori, Matthias Pirlichj, Hermann Scharfetterk, Annemie M.W.J. Scholsl, Claude Pichardm, Composition of the ESPEN Working Group (00) Bioelectrical impedance analysis part I: review of principles and methods. Clinical Nutrition, S. Grimnes and Ø. G. Martinsen 000 Bioimpedance and Bioelectricity Basics. San Diego, CA: Academic Press H.C. Lukaski 00 Evaluation of body composition: why and how? Mediterr J Nutr Metab :, DOI.0/s-00-00-x S. Grimnes and Ø. G. Martinsen, Wiley Encyclopedia of Biomedical Engineering, Copyright & 00 John Wiley & Sons, Inc., J. Hlubik 00, Imedane in medicine: measurin specific body impedance, Masterss degree thesis J. Rosell-Ferrer, L. Nescolarde, and J. Elvira, Total Body Water Changes Using Segmental Bioimpedance in Healthy Population with Similar Anthropometry, IFMBE Proceedings /VII, p. 0 ff. L Nescolarde, M A García-González, J Rosell-Ferrer, T Doñate and U Querfeld, Thoracic versus whole body bioimpedance measurements: the relation to hydration status and hypertension in peritoneal dialysis patients, L Nescolarde et al 00 Physiol. Meas. -