ORIGINAL ARTICLE INTRODUCTION

Similar documents
Influence of cervical preflaring on apical file size determination - An in vitro study

An In Vivo Evaluation of Two Types of Files used to Accurately Determine the Diameter of the Apical Constriction of a Root Canal: An In Vivo Study

Working length changes following straight-line access and different coronal flaring methods

Endodontics. Lec.7 د. حسن الرماحي 5 th class. Obturation techniques

Three-Dimensional, Dense and Durable Obturation of Root Canals

Residual dentin thickness in mesial roots of mandibular molars prepared with Lightspeed rotary instruments and Gates- Glidden reamers

Staining Potential of Calcium Hydroxide and Monochlorophenol Following Removal of AH26 Root Canal Sealer

The Graduate School Yonsei University Department of Dentistry Myoungah Seo

Influence of plugger penetration depth on the area of the canal space occupied by gutta-percha

Creating a glide path for rotary NiTi instruments: part two

Classic Technique Guide

Leakage along warm gutta-percha fillings in the apical canals of curved roots

Comparison of apical and coronal sealing in canals having tapered cones prepared with a rotary NiTi system and stainless steel instruments

Shah. Management of a maxillary second premolar with an S-shaped root canal - An endodontic. Management of a maxillary second premolar

Density of Gutta Percha by Weight in Straight Root Canals and Curved Root Canals after Single Cone, Cold Lateral, and Warm Vertical Condensation

A great file. Even better.

Endo Easy Efficient one file endo

WaveOne Gold reciprocating instruments: clinical application in the private practice: Part 2

In vitro evaluation of root canal preparation with plastic endodontic rotary finishing file - A SEM study

Safety and Simplicity!

Comparison of Spreader Penetration during Lateral Compaction of 0.04 and 0.02 Tapered Gutta-Percha Master Cones

A COMPARATIVE STUDY OF ROOT CANAL FILLINGS BASED ON WARM GUTTA-PERCHA CONDENSATION TECHNIQUES

ENDODONTOLOGY ABSTRACT INTRODUCTION

Integra Miltex. Endodontic Files. Limit uncertainty with the brand you trust

In vitro evaluation of root canals obturated with four different techniques. Part 3: Obturation of lateral canals

Evaluation of retrievability using a new soft resin based root canal filling material

INTERNATIONAL JOURNAL OF CURRENT RESEARCH IN CHEMISTRY AND PHARMACEUTICAL SCIENCES

Instructions for use: FlexMaster. the rotary NiTi-System for every case. Endo Easy Efficient

You succeed your root canal treatments! Characteristics...page 4. Instruments...page 6. Protocol...page 10. Questions & Answers...

A comparison of stainless steel hand and rotary nickel-titanium instrumentation using a silicone impression technique

Root Canal Treatment. with a mechanical treatment system. Clinical case

Obturation of internally prepared cavities (simulating internal resorption) with three different techniques

Endo Easy Efficient. The efficient NiTi system. User Information.

ANATOMIC. XP-endo Finisher. optimal cleaning while preserving dentine

Before we begin demonstrating the shock of paradigms on the instrumentation

Endodontics. Patented partial heat treatment Improved safety

5 Days Comprehensive Endodontic Course Topics

PLATE 1. Outline Form

endodontics 88 MARCH 2013» dentaltown.com feature by Kenneth Koch, DMD and Ali Nasseh, DDS, MMSc

Shaping Ability of Four Rotary Nickel-Titanium Instruments to Prepare Root Canal at Danger Zone

Case Note Retrieval of a separated file using Masserann technique: A case report

Innovative revolutionary approach to root canal preparation

Evaluation of Gutta-Percha-Filled Areas in Root Canals after Filling by Two Different Obturation Techniques

one file endo Endo Easy Efficient

Final Thesis Defense Examination. Anthony L. Horalek, DDS June 12, 2002

Last Generation Endodontic Instruments. A Study of their. Drs. Siragusa and Racciatti are affiliated with the Department of

ENDODONTIC OVERFILLS:

Instructions For Use

Failure of ProFile instruments used with air, high torque control, and low torque control motors

Evaluation of root filling quality when using Reciproc - a rotary system, and conventional manual instrumentation

A comparison of root canal preparations using stainless steel, Ni-Ti hand, and Ni-Ti engine-driven endodontic instruments an in vitro study

Survey on Knowledge about Access Cavity Preparation

Tools for Endodontic Success

Field Guide to the Ultrasonic Revolution

MDJ The effects of canal preparation by different NiTi rotary Vol.:9 No.:2 2012

Case Report Endodontic Management of Maxillary Second Molar with Two Palatal Roots: A Report of Two Cases

Evaluation of the effect of root canal preparation size and flaring on the depth of irrigant penetration (In vitro study)

D.T. LIGHT-POST. Instructions for Use. Bisco 0459 D.T. LIGHT-POST X-RO. Radiopaque Translucent Fiber Post System ILLUSION

THREE-DIMENSIONAL OBTURATION

XP-endo Shaper. The One to Shape your Success

Journal of American Science 2014;10(12)

EndoWave. Enhanced safety for root canal preparation. Thinking ahead. Focused on life.

Corresponding Author:Dr.Sneha Vaidya 3

36 year-old Caucasian male presented for evaluation and treatment of tooth #3.

Management of a Type III Dens Invaginatus using a Combination Surgical and Non-surgical Endodontic Therapy: A Case Report

Root end preparation techniques Summary of papers

Outcome of Root Canal Treatment Using Soft-Core and Cold Lateral Compaction Filling Techniques: A Randomized Clinical Trial

Smear layer removal evaluation of different protocol of Bio Race file and XPendo Finisher file in corporation with EDTA 17% and NaOCl

5/8/2012. Endodontics. Root Canal Preparation Root Canal Filling. Coronal Access. Isolation. Follow-up. Diagnosis

KING SAUD UNIVERSITY College of Dentistry. Department of Restorative Dental Sciences DIVISION OF ENDODONTICS COURSE OUTLINE 323 RDS

Case report for the new HyFlex CM NiTi File system of Coltene Endo

D.T. LIGHT-POST. Bisco. Instructions for Use. Radiopaque Translucent Fiber Post System. Double Taper

WHERE SAFETY MEETS EFFICIENCY

Cleaning Efficiency of Nickel Titanium GT and.04 Rotary Files when used in a Torque Controlled Rotary Handpiece

Fundamentals of Endodontics Peter Briggs, Ahmed Farooq and Tracy Watford, Trish Moore and QED

Jim Ruckman. 65 year-old Caucasian female presented for evaluation and treatment of tooth #19.

L. W. M. van der Sluis, M. K. Wu & P. R. Wesselink. Introduction. Abstract

Advanced ESX Instrumentation:! Segmental Crown Down & Hybridization of Tapers!

Endo Easy Efficient. one file endo. The RECIPROC Technique Steps to Success.

Maxillary Molar Endodontic Case Presentation. R.Bose. BDS (Manc 2010), General Dental Practitioner, Oxford/London.

Case Report Endodontic Treatment of Bilateral Maxillary First Premolars with Three Roots Using CBCT: A Case Report

Original article: A Comparative evaluation of three different Ni-Ti rotary files using Crown Down technique. An Exvivo study using C T scan.

Case Report Root Canal Treatment of Mandibular Second Premolar with Three Separate Roots and Canals Using Spiral Computed Tomographic

Minimally Invasive Endodontics for Better and Safer Treatment

A WHOLE NEW DIMENSION OF TOTAL PERFORMANCE.

Comparison of the Remaining Dentin Thickness in the Root after Hand and Four Rotary Instrumentation Techniques: An in vitro Study

Effective cleaning and shaping of the root

Diagnosis and Treatment of Three-Rooted Maxillary Premolars

Dowel restorations Treatment with a post and core

ENDO- DONTICS ENDODONTIC THERAPY

THE GENERAL DENTIST AND TIMELY REFERRAL TO THE ENDODONTIST

Evaluation of apical and lateral extrusion of sealer using different sized thermoplastized obturators.

In vitro Study of Apically Extruded Debris and Irrigant Following the Use of Conventional and Rotary Instrumentation Techniques

Instruments used in Endodontics

Incidence of Apical Crack Initiation during Canal Preparation using Hand Stainless Steel /jp-journals

Race family Endodontic NiTi rotary files

Torque During Canal Instrumentation Using Rotary Nickel-Titanium Files

Comparison of the Different Techniques to Remove Fractured Endodontic Instruments from Root Canal Systems

Celebrating 30th Anniversary of DiaDent Specialized GUTTA PERCHA & PAPER POINTS REFERENCE GUIDE

Use and description of endodontic instruments

Transcription:

ORIGINAL ARTICLE IN VITRO MICROSCOPIC ANALYSIS OF APICAL 3MM OBTURATION AFTER GT, LIGHTSPEED, AND PROFILE ROOT CANAL PREPARATION Mian Khalid Iqbal, Louay Abrass, Marlene Oviedo-Marmo, Helmut Walsch. ABSTRACT Objective: To compare the quality of continuous wave obturation technique following preparation of the apical third with three different NiTi rotary instrumentation systems. Methodology: Mesiobuccal canals of 75 extracted human maxillary and mandibular molars were used in study. After instrumentation 25 canals each with GT ProFile.06 and LightSpeed, canals were obturated with continuous wave technique 3-5 mm from the working length. Roots were sectioned at 1mm, 2 mm, and 3 mm from the apex and stained with methylene blue. Two operators evaluated pictures of each section (24X) for obturation quality. Grades of 1- good adaptation, thin sealer film; 2- irregularities with thick film of sealer separating gutta-percha for up to 1/3 from the canal walls; 3- voids or thick film of sealer separating gutta-percha from the canal walls for more than 1/3 were assigned. Results: The average obturation grade at 1mm was GT= 2.16, ProFile =1.96, LightSpeed =1.80; at 2 mm GT =1.84, ProFile =1.52, LightSpeed =1.52; at 3 mm GT =1.40, ProFile =1.40, LightSpeed =1.20. Overall LightSpeed showed better results but Kruskal-Wallis test showed no differences among groups at all three levels. Statistically significant improvements were revealed in the quality of filling as the distance from the apex increased. Conclusion: Under the conditions of this study, root canals shaped by GT, LightSpeed and ProFiles revealed similar quality of root canal obturation. The quality of root canal obturation improved in all groups as the distance from the apex increased. Key words: Apical obturation, root canal preparation, GT, lightspeed, profile curved canals. INTRODUCTION The success of a root canal treatment depends on the removal of pulp tissue, bacteria, and necrotic debris combined with adequate canal shaping to facilitate obturation. With cleaning and shaping being the most tedious and demanding phase of endodontic therapy, the practitioner must define certain instrumentation goals. The goals of endodontic instrumentation are to: (1) instrument with control so that there is enlargement without deviation from the original canal; (2) instrument to a size that is consistent with total mechanical and chemical debridment; (3) debride the root canal system from its Department of Endodontics, University of Pennsylvania, USA. Correspondence: Dr. Mian K. Iqbal, 901 Carroll Road, Wynewood, PA 19096, USA. Received November 2, 2006: accepted: January 26,2007. JDUHS 2007, Vol. 1 (1): 10-14 coronal orifice to its working length, regardless of canal curvature; and (4) create a shape that tapers from the coronal orifice to the apical opening. Techniques for instrumentation to a predetermined size are described. It is agreed that the larger the apical preparation size the better the chance of achieving optimal debridment 1,2. Whereas most of these criteria are easily achieved in straight canals, fulfilling these goals can be very difficult in curved canals. In order to alleviate the effects of canal curvature on the apical portion of the instrument, crown down preparation of the root canals is advocated 3. A number of preparation techniques are described to provide an optimum shape at the end of instrument preparation 4, 5. In a study comparing six different instruments and instrumentation techniques, roots were cross-sectioned at 2, 5, and 9 mm from the apex to determine the quality of canal preparation. In this study, LightSpeed instruments had the largest number of 10

In vitro microscopic analysis of root canal preparation round canals at all levels, which are considered most desirable 6. A round apical preparation is believed more likely to ensure cleaning of all canal walls, subsequently assuring a better apical seal 7.This new generation of NiTi rotary instruments potentially allowed shaping of narrow, curved root canals, without causing significant aberrations 8-10. In a study comparing LightSpeed and stainless steel K- files using simulated curved canals, the LightSpeed stayed centered in the canals maintaining the central axis, with minimal incidence of transportation, elbow formation and zipping 11. In another study comparing engine-driven NiTi instrument systems to hand files, again it was not surprising to find that the NiTi systems remained better centered in the canal than the stainless steel hand files 12. Furthermore, the investigators found no significant difference among NiTi rotary systems at sections taken 1, 3, 5 mm from working length using video imaging. Figure 1 a: Grade (1): well adapted GP with a thin film of sealer with no voids or irregularities. The purpose of this study was to evaluate the quality of different combinations of instrumentation and obturation techniques based on the centerness and roundness of preparation and the adaptation of gutta-percha to the prepared dentinal wall. MATERIALS AND METHODS It was an experimental in-vitro study. Mesiobuccal canals of 75 extracted human molar teeth with completely formed apices were used. All teeth were cleaned and shaped similarly except for the apical 4 mm. Radiographs were taken pre-operatively, working length, mid-op (cone fit), and post-operatively with Reprosil putty impression material from BL and MD angulations for each tooth. Each tooth was accessed with divergent walls, exposing all canal orifices with straight-line access. Coronal flare was employed using Gates Glidden burs (# 4-2) in the coronal 2/3 of the canal or where curvature permitted. Patency was achieved with #8 file passively inserted into the canal until the tip of the file was visible outside the apex. The working length was obtained by subtracting 0.5mm from this measurement. The apical width was gauged using K-file and LightSpeed. The larger of the two was used to prepare the canals to a minimum of four sizes larger except for GT instrumentation where apical size was maintained at ISO size 20. The canals were then instrumented 4 mm short of WL using GT files. The apical 4 mm was prepared using three different techniques i.e. Profiles (.06), GT, and LightSpeed with 25 canals to each technique. Irrigation was carried out with 17% EDTA solution after each instrument. A final soak of 5.25% NaCL for 6 minutes, coupled with use of patency file. Obturation of Figure 1 b: Grade (2): voids or irregularities with thick film of sealer separating GP for up to 1/3 of the canal walls. Figure 1 c: Grade (3): voids or irregularities with thick film of sealer separating GP from the canal walls for more than 1/3. the 75 canals was carried out using warm vertical technique with System B penetration 3-5 mm from WL with Obtura back-fill. Root section was then done with Isomet slow speed saw perpendicular to the long axis of the canal determined both by visual and radiographic inspection of each root. Each root was sectioned 1mm, 2 mm, 3 mm and 4 mm from the anatomic apex. A Sony digital camera attached to the Moller microscope with X 24 magnification was used to take pictures of the sections. Pictures were numbered without reference to the method of instrumentation. Two different operators viewed the pictures for the quality of instrumentation and obturation. Obturation was assessed on the ratio of GP to sealer, adaptation of GP to canal walls and homogeneity of the JDUHS 2007, Vol. 1 (1): 10-14 11

Main K. Iqbal, Louay Abrass, Marlene Oviedo-Marmo, Helmut Walsch GP (presence of voids or multiple cones surrounded by sealer). Grades of 1 (good), 2 (acceptable) and 3 (unacceptable) were assigned using the following criteria: Grades of 1- Table I shows that the grades improved as the distance from the apex increased. This is evidenced by the slight decrease in average grades in Figure 2. The results of Kruskal-Wallis test revealed statistically significant differences between 1mm level and 3 mm level for all instrumentation systems. A similar trend was also noticed between 2 mm level and 3 mm level except for the ProFile group in which evaluation grades at these levels were not significantly different from one another. DISCUSSION Figure 2: Distance from anatomic apex. good adaptation, thin sealer film; 2- irregularities with thick film of sealer separating gutta-percha for up to 1/3 in (fig. 1 a-c) from the canal walls; 3- voids or thick film of sealer separating gutta-percha from the canal walls for more than 1/3. The statistical analysis of the obturation grades results were analyzed using the non-parametric Kruskal-Wallis test. RESULTS Means and standard deviations of grades obtained by each instrumentation system at three different evaluation levels are shown in Table I. These results are plotted in Table 1: A Comparison of Obturation Grades among Three NiTi Rotary Systems. Level GT Lightspeed Profile 1 mm 2 mm 3 mm Total Mean±SD Mean±SD Mean±SD 2.16± 0.80 a 1.84 ± 0.75 a 1.40 ± 0.58 b 1.80± 0.82 a 1.52 ± 0.65 a 1.20 ± 0.50 b 1.96± 0.84 a 1.52± 0.77 ab 1.40± 0.65 b 1.80± 0.77 1.51± 0.70 1.63± 0.78 SD = Standard Deviation Values followed by a similar superscripts across columns are not statistically significant from one another Figure 2. Canals prepared with GT exhibited the highest average grade at the 1mm and 2 mm levels (i.e. least favorable) while GT and Profile had the same average obturation grades at the 3 mm level. On the other hand, LightSpeed achieved the lowest average grade (i.e. most favorable) at the 1mm and 3 mm levels, while it achieved an equal and average grade with ProFile at the 2 mm level. However, the results of the Kruskal-Wallis test did not show any statistically significant difference among obturation grades obtained by the three instrumentation systems at the three different levels (p>0.05). In this study, the ability to produce a round preparation using three NiTi instruments in apical 3 mm and its subsequent effect on apical obturation quality using continuous wave technique was compared. The warm vertical technique used in this investigation is known to replicate the root canal preparations better than the cold lateral condensation technique 13. Overall, instrumentation shapes produced by LightSpeed NiTi rotary instruments achieved the most favorable scores for obturation but the results were not statistically significant. These results are similar to a recent study that found the distribution of filling materials similar in all combinations of instrumentation and obturation techniques 14. A statistically significant trend in improvement of evaluation grade was noticed as the distance from the apex increased. The results indicated that at 3 mm from the apex, all the NiTi rotary instruments used in this study shaped the canals adequately for optimal obturation. The favorable results achieved at 3 mm level can be attributed to a number of factors. Firstly, a continuous wave technique was used which may have achieved better plasticization of gutta-percha at 3mm level 15. The penetration depth of the plugger has been significantly related to percentage of gutta percha found in root canal 16. In this study, the depth of penetration of system B tip was 3 to 4 mm short of working length and may have led to optimal filling of root canals at this level. Secondly, the quality of root canal filling in oval shaped canals can be compromised 17, 18. Due to the tapered nature of the instruments the preparations at 3 mm level were considerably larger than one at 1 mm level. As a result of which the irregular shape of root canals at 3 mm level gained a more rounded shape, which is more amenable to traditional root canal obturation techniques. However, it is realized that apical 1 mm of the root canal JDUHS 2007, Vol. 1 (1): 10-14 12

In vitro microscopic analysis of root canal preparation remains the most critical area and the instrumentation techniques used in this study were not able to ideally shape it for optimal obturation. The warm vertical gutta-percha compaction technique requires canals to be sufficiently flared to allow the tip of the plugger to penetrate to the apical third 19. In this study, the apical 4 mm of the canals was prepared using three different instruments however the differences in taper achieved at the apex did not translate into differences in quality of obturation. One of the important factors that influenced the results of this study is the original canal morphology, which varies greatly between different teeth groups and even between different roots of the same tooth. It is realized that root canals are not always rounded in shape but may exhibit larger bucco-lingual dimension ranging from an oval to a ribbon shaped configuration 20. Therefore, theoretically the smallest size of instrument to obtain a rounded preparation can vary greatly within every type of canal 1. In this study, the samples were randomized rather than categorized by root canals. It is envisaged that a study with larger sample size would have neutralized the effect of root canal morphology, and would have more accurately delineated the effectiveness of different instrumentation techniques. Grading of obturation results were conducted by subjective evaluation of micrographs in the current study. Although consensus of two operators was used to reduce the subjective interpretation of results, more objective evaluation scheme for the micrographs may improve the quality of the data. For example, image analysis software could be utilized in the future to quantify the roundness and regularities of the canal preparation and provide a quantitative evaluation of the ratio of guttapercha to sealer instead of the subjective ratings used for this study. The ability to achieve an apical seal with contemporary obturation methods primarily depends on the quality of the apical preparations. Round apical preparations will ensure a better obturation. CONCLUSION Under the conditions of this study, root canals shaped by GT, LightSpeed and ProFiles revealed similar quality of root canal obturation. The quality of root canal obturation improved in all groups as the distance from the apex increased. REFERENCES 1. Kerekes K, Tronstad L. Morphological observation the root canals of human molars. J Endod 1977; 3:114-8. 2. Green E. Microscopic investigation of root canal diameters. J Am Dent Assoc 1958;57:636-44. 3. Morison ME, Holcomb J B. The MCV crown-down technique: a modified alternative coronal flaring approach for endodontics. Virginia Dent J 1988; 65:32-8. 4. Mullaney TP. Instrumentation of finely curved canals. Dent Clin North Am 1979; 23: 575-92. 5. Roane JB, Sabala CL, Duncanson MG. The "balanced force" concept for instrumentation of curved canals. J Endod 1985; 11:203-11. 6. Roig-Cayon M. A comparison of molar root canal preparations using six instruments and instrumentation techniques. J Endod 1997; 23: 383-6. 7. Luks S. Gutta-percha versus silver points in the practice of endodontics. NY State Dent J 1965;31:341-50. 8. Thompson SA, Dummer PM. Shaping ability of LightSpeed rotary nickel-titanium instruments in simulated root canals. Part 1. J Endod 1997;23:698-702. 9. Thompson SA, Dummer PM. Shaping ability of LightSpeed rotary nickel-titanium instruments in simulated canals. Part 2. J Endod 1997;23:742-7. 10. Portenier I, Lutz F, Barbakow F. Preparation of the apical part of the root canal by LightSpeed and step-back techniques. Int Endod J 1998;31:103-11. 11. Tharuni SL, Parameswaran A, Sukumaran VG. A comparison of canal preparation using K-file and LightSpeed in resin blocks. J Endod1996; 22:474-6. 12. Short JA, Morgan LA,. Baumgartner JC. A comparison of canal centering ability of four instrumentation techniques. J Endod 1997; 23: 503-7. 13. Collins J, Walker MP, Kulild J et al. A comparison of three gutta-percha obturation techniques to replicate canal irregularities. J Endod 2006;32:762-5. 14. Kececi AD, Unal GC, Sen BH. Comparison of cold lateral compaction and continuous wave of obturation techniques following manual or rotary instrumentation. Int Endod J 2005;38:381-8. 15. Sobhi MB, Rana MJ, Ibrahim M et al. Comparison of vertical with lateral condensation technique in obturation of root canal system. J Coll Physicians JDUHS 2007, Vol. 1 (1): 10-14 13

Main K. Iqbal, Louay Abrass, Marlene Oviedo-Marmo, Helmut Walsch Surg Pak 2004;14: 455-8. 16. Jung IY, Lee SB, Kim ES et al. Effect of different temperatures and penetration depths of a System B plugger in the filling of artificially created oval canals. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2003; 96: 453-7. 17. Van der Sluis LW, Wu MK, Wesselink PR. An evaluation of the quality of root fillings in mandibular incisors and maxillary and mandibular canines using different methodologies. J Dent 2005;33:683-8. 18. Wu MK, van der Sluis LW, Wesselink PR. A preliminary study of the percentage of gutta-perchafilled area in the apical canal filled with vertically compacted warm gutta-percha. Int Endod J 2002; 35:527-35. 19. Diemer F, Sinan A, Calas P. Penetration depth of warm vertical Gutta-Percha pluggers: impact of apical preparation. J Endod 2006; 32:123-6. 20. Wu MK, R'oris A, Barkis D et al. Prevalence and extent of long oval canals in the apical third. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2000; 89:739-43. JDUHS 2007, Vol. 1 (1): 10-14 14