Shaping ability of ProTaper Universal, WaveOne and ProTaper Next in simulated L-shaped and S-shaped root canals

Similar documents
in simulated curved canals

Comparison of cyclic fatigue resistance of original and counterfeit rotary instruments

WHERE SAFETY MEETS EFFICIENCY

Shaping ability of progressive versus constant taper instruments in curved root canals of extracted teeth

Research Article Centering Ability of ProTaper Next and WaveOne Classic in J-Shape Simulated Root Canals

Comparative study on the shaping ability and cleaning efficiency of rotary Mtwo instruments. Part 1. Shaping ability in simulated curved canals

ENDO-EZE TM GENIUS ENDODONTIC SYSTEM WHERE SAFETY MEETS EFFICIENCY

Evaluation of canal preparation with rotary and hand Niti files in curved root canals using Cone Beam Computed Tomography: An In Vitro Study

Comparison of the shaping ability of Twisted Files with ProTaper and RevoS nickel-titanium instruments in simulated canals

flexible performance Chemin du Verger 3 CH-1338 Ballaigues Switzerland

An in vitro comparison of different techniques for glide path preparation

Creating a glide path for rotary NiTi instruments: part two

Original Study. Annals of Dental Specialty Vol. 6; Issue 1. Jan Mar

Endodontic Shaping Performance Using Nickel Titanium Hand and Motor ProTaper Systems by Novice Dental Students

WaveOne Gold reciprocating instruments: clinical application in the private practice: Part 2

Original article: A Comparative evaluation of three different Ni-Ti rotary files using Crown Down technique. An Exvivo study using C T scan.

A Shift Up In Performance. Performance Refined

Comparison of Canal Preparation Pattern of K3 and ProTaper Rotary Files in Curved Resin Blocks

Comparison of canal preparation pattern of K3 and ProTaper rotary files in curved resin blocks

Fauzia Ashraf, Pushpa Shankarappa, Abhinav Misra, Asheesh Sawhney, Nandamuri Sridevi, and Anu Singh

WaveOne Gold. Surf the canal with confidence

QUINTESSENCE INTERNATIONAL ENDODONTICS

A comparison of canal centering abilities of four root canal instrument systems using X-ray micro-computed tomography

Shaping Ability of ProTaper Next, WaveOne, and Reciproc in Simulated Root Canals

CBCT EVALUATION OF CANAL TRANSPORTATION USINGNEWER ROTARY NI-TI FILE SYSTEMS-AN IN VITRO STUDY.

EndoWave. Enhanced safety for root canal preparation. Thinking ahead. Focused on life.

Comparison of canal transportation in simulated curved canals prepared with ProTaper Universal and ProTaper Gold systems

Case report for the new HyFlex CM NiTi File system of Coltene Endo

Race family Endodontic NiTi rotary files

MDJ The effects of canal preparation by different NiTi rotary Vol.:9 No.:2 2012

CBCT Evaluation Of Glidepath Preparation By Different Rotary Nickel Titanium Glide Path...

Nickel-titanium (NiTi) rotary instruments were introduced to improve root canal

Surf the canal with confidence

Research Article Centering Ability and Influence of Experience When Using WaveOne Single-File Technique in Simulated Canals

You succeed your root canal treatments! Characteristics...page 4. Instruments...page 6. Protocol...page 10. Questions & Answers...

IN VITRO EVALUATION OF DENTINAL

Effective cleaning and shaping of the root

canal shaping capabilities of the ProTaper Universal and ProTaper Gold rotary instrument systems

LegacyENDO. Create your own Legacy! Controlled Memory Cross Cut. Apex Access. Multi Taper. K-Files

Failure of ProFile instruments used with air, high torque control, and low torque control motors

In vitro evaluation of root canal preparation with plastic endodontic rotary finishing file - A SEM study

Last Generation Endodontic Instruments. A Study of their. Drs. Siragusa and Racciatti are affiliated with the Department of

Innovative revolutionary approach to root canal preparation

A WHOLE NEW DIMENSION OF TOTAL PERFORMANCE.

thinking beyond cyclic fatigue Testing standards for endo files vary and there are other qualities to be concerned with, too

Microstructural and mechanical characterizations of new Ni-Ti endodontic instruments

Torsion Property and Cyclic Fatigue Fracture Behavior of. Nickel-Titanium Endodontic Instruments

Safety and Simplicity!

ORIGINAL PAPERS. Porównanie skuteczności opracowania sztucznych kanałów w kształcie litery L dwoma systemami maszynowymi: Hyflex CM i ProTaper Next

Endodontics. Patented partial heat treatment Improved safety

The WaveOne reciprocating endodontic system

Lifespan of One Shape Files used in Severely Curved Canals in Resin Blocks and Extracted Teeth

ANATOMIC. XP-endo Finisher. optimal cleaning while preserving dentine

Instructions for use: FlexMaster. the rotary NiTi-System for every case. Endo Easy Efficient

Buy Direct. Buy Brasseler USA. Systems for Endodontic Excellence. R a Ce T M. Rotary Endodontic System with Safety Memo Disc. RaCe TM.08. RaCe TM.

one file endo Endo Easy Efficient

Cyclic fatigue life of Tango-Endo, WaveOne GOLD, and Reciproc NiTi instruments

Dentinal crack formation during root canal preparations by the twisted file adaptive, Reciproc and WaveOne instruments

Fracture and deformation of ProTaper Next instruments after clinical use

Shaping Potential of Manual NiTi K-File and Rotary ProTaper and Analyzing the Final Outcome of Shaped Canals using CT

Endo Easy Efficient. The efficient NiTi system. User Information.

R J M E Romanian Journal of Morphology & Embryology

Shaping ability of BioRace, ProTaper NEXT and Genius nickel-titanium instruments in curved canals of mandibular molars: a MicroCT study

Endo Easy Efficient one file endo

Influence of cervical preflaring on apical file size determination - An in vitro study

Geometric and dimensional characteristics of simulated curved canals prepared with protaper instruments

IN VITRO EVALUATION OF ROOT CANAL PREPARATION WITH TWO ROTARY INSTRUMENT SYSTEMS PRO TAPER AND HERO SHAPER

Working length changes following straight-line access and different coronal flaring methods

by Drs. Clifford J. Ruddle, Pierre Machtou and John D. West

The Graduate School Yonsei University Department of Dentistry Myoungah Seo

SINGLE FILE SYSTEM FOR MODERN ENDODONTICS SMART CONTRA-ANGLE HANDPIECE WITH RECIPROCATING MOTION

A great file. Even better.

Comparison of Canal Transportation and Centering Ability of Rotary I-Race and BT-Race Systems using Cone Beam Computed Tomography: An in vitro Study

Improve Your Root Canal Preparations with Adaptive Motion Technology

irace Quick, effective and safe

CIC Edizioni Internazionali. In vitro resistance to fracture of two nickel-titanium rotary instruments made with different thermal treatments

Effect of movement kinematics on canal transportation: reciprocation with different angles, adaptive motion, and continuous rotation

Available online at International Journal of Current Research Vol. 8, Issue, 08, pp , August, 2016

Evaluation of selected mechanical properties of NiTi rotary glide path files manufactured from controlled memory wires

In vitro Study of Apically Extruded Debris and Irrigant Following the Use of Conventional and Rotary Instrumentation Techniques

Failure of ProTaper rotary Ni-Ti instruments used by undergraduate students

Single File Reciprocating Technique Using Conventional Nickel Titanium Rotary Endodontic Files

SINGLE-FILE SHAPING TECHNIQUE

Canal anatomy modifications by using path files, glide path instruments analysed by Cone Beam Computed Tomography

A comparative scanning electron microscopic study of the effect of three different rotary instruments on smear layer formation

Vertical Root Fracture initiation in curved roots after root canal preparation: A dentinal micro-crack analysis with LED transillumination

Comparison of shaping ability between single length technique and crown-down technique using Mtwo rotary file

JCDP ORIGINAL RESEARCH ABSTRACT INTRODUCTION

Basic Research Technology

Comparison of the Remaining Dentin Thickness in the Root after Hand and Four Rotary Instrumentation Techniques: An in vitro Study

Celebrating 30th Anniversary of DiaDent Specialized GUTTA PERCHA & PAPER POINTS REFERENCE GUIDE

ORIGINAL ARTICLE INTRODUCTION

IJCMR 214. REVIEW ARTICLE Root Canal Curvatures: A Literature Review. Smita Agrawal 1, Swapna.D.V 2, Roopa. R Nadig 3, Bijo Kurian 1

Research Article Effect of Patency File on Transportation and Curve Straightening in Canal Preparation with ProTaper System

Gorduysus MO et al. Operating Microscope improves ability to locate and negotiate second canal

Evaluation of canal preparation with Ni-Ti rotary files by micro computed tomography

In-vitro Comparison of NiTi Tee, RaCe and Protaper Instruments in Dentinal Crack Formation

Transportation of Severely Curved Canals: Comparison of One Shape and K3 Rotary Systems

A COMPARATIVE STUDY OF ROOT CANAL FILLINGS BASED ON WARM GUTTA-PERCHA CONDENSATION TECHNIQUES

Tools for Endodontic Success

Transcription:

Wu et al. BMC Oral Health (2015) 15:27 DOI 10.1186/s12903-015-0012-z RESEARCH ARTICLE Open Access Shaping ability of ProTaper Universal, WaveOne and ProTaper Next in simulated L-shaped and S-shaped root canals Hui Wu 1, Cheng Peng 1,2, Yulong Bai 1, Xin Hu 1, Lei Wang 1 and Changyi Li 1* Abstract Background: The purpose of this study was to compare the shaping ability of the ProTaper Universal (PTU; Dentsply Maillefer, Ballaigues, Switzerland), WaveOne (WO; Dentsply Maillefer) and ProTaper Next (PTN; Dentsply Maillefer) in simulated L-shaped and S-shaped root canals respectively. Methods: 30 simulated L-shaped and 30 simulated S-shaped root canals in resin blocks were employed and randomly divided into 3 groups (n = 10), respectively. The canals were prepared to a tip size 25 using PTU, WO or PTN: PTU F2 (taper 0.08 over the first 3 mm from apical tip), WO Primary (taper 0.08 over the first 3 mm from apical tip), and PTN X2 (taper 0.06 over the first 3 mm from apical tip). Photos of the simulated root canals were taken pre- and postinstrumentation. The 2 layers were superimposed after a series of image processing and 10 points were selected from apical constriction with 1 mm interval. And then the central axis transportation and straightened curvature were measured with software of image analysis. Results: In simulated L-shaped root canals, PTU and PTN caused less transportation than WO at curved section (P < 0.05), and PTN caused the least transportation at apical constriction (P < 0.05). Moreover, PTN maintained the canal curvature best among the 3 groups (P < 0.05). But PTN produced more transportation at straight section compared with PTU and WO (P < 0.05). In simulated S-shaped root canals, PTN preserved the coronal curvature best (P < 0.05), but there was no significant difference in apical curvature since all the files straightened the curvature obviously. Conclusions: PTN showed a better shaping ability than PTU and WO at the curved section of root canals, and PTN maintained the best apical constriction. But all the files had a tendency to straighten the apical curvature in multi-curved canals. Keywords: Central axis transportation, Curvature straightening, ProTaper Universal, WaveOne, ProTaper Next Background Root canal preparation is regarded as one of the most important steps in endodontic treatment. Its main goals are to remove the infected and necrotic tissue out of root canals, to create smooth walls facilitating irrigation and obturation, to preserve the anatomy of apical foramen, and to conserve the sound root dentine for long term effect [1,2]. Nowadays, many kinds of Nickel-Titanium (Ni-Ti) rotary files have been invented to facilitate root canal preparation, such as PTU, WO and PTN. The * Correspondence: changyi_li@sina.com Equal contributors 1 School of Stomatology, Tianjin Medical University, #12 Qi Xiang Tai Road, He Ping District, Tianjin 300070, PR China Full list of author information is available at the end of the article application of these files has greatly improved cutting efficiency and safety compared with stainless steel files [3]. PTU is made of conventional Ni-Ti wire and has been widely used in root canal treatment, while both WO and PTN are made of M-wire. WO works in a reciprocating mode and finishes root canal preparation with only one file in most cases [4]. PTN is a successor to PTU. And the cross section of PTN is an off-centred rectangle which makes the file rotated in a unique asymmetric motion like a snake [5]. Shaping ability and cyclic fatigue resistance are of special importance when evaluating the performance of Ni-Ti files. Furthermore, central axis transportation and curvature straightening of root canals are two important 2015 Wu et al.; licensee BioMed Central. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Wu et al. BMC Oral Health (2015) 15:27 Page 2 of 7 parameters for estimating the shaping ability of Ni-Ti files. Simulated root canals in resin blocks are usually recognized as valid study models to avoid the variation among natural teeth [6], since simulated root canals could be manufactured by standardization of working length, taper, curvature, and tissue hardness in three dimensions [2]. To date, there have been some studies about shaping ability of PTU, WO and PTN. But the results differ from each other in separate studies. For example, Capar et al. [7] demonstrated that there was no significant difference of canal transportation and centering ratio among PTU, WO and PTN. But Yoo and Cho [8] found that WO followed the original pathway better than PTU. The possible reason for that discrepancy could be attributed to different calculation methods, even though both studies focused on analyzing the outline change of root canals to estimate the canal transportation [7,8]. Nevertheless, the present study was to acquire the central axis pre- and postinstrumentation using software of image analysis, and to directly measure the central axis transportation and curvature straightening of canals after preparation with PTU, WO and PTN. The null hypothesis was that there is no difference among the 3 rotary Ni-Ti file systems regarding the analyzed parameters. Methods Simulated root canals preparation 30 simulated L-shaped root canals (Endo Training-Bloc-L, Dentsply Maillefer) and 30 simulated S-shaped root canals (Endo Training-Bloc-S, Dentsply Maillefer) were randomly divided into 3 groups respectively (n = 10). All these canals were 0.02 taper over the 16 mm canal length. At first, #10 K-file (Dentsply Maillefer) and #13, #16 PathFile (Dentsply Maillefer) were used to glide pathway to 16 mm working length. And then, the L-shaped and S-shaped canals were prepared according to the following sequences: group PTU: #19 PathFile, PTU (SX, S1, S2, F1, F2); group WO: #19 PathFile, WO Primary; group PTN: PTN (X1, X2). And #19 PathFile was not used since PTN X1 was size 17, 0.04 taper. During instrumentation, all simulated root canals were prepared by same experienced operator and enlarged to an apical size 25. Group PTU was prepared with a crown-down technique, while group WO and group Figure 1 Image processing of L-shaped canal. (Stage 1A) the photograph was desaturated before instrumentation; (Stage 1B) the photograph was desaturated after instrumentation; (Stage 2A) the image was converted into vector one before instrumentation; (Stage 2B) the image was converted into vector one after instrumentation; (Stage 3) images pre- and postinstrumentation were superimposed into one after acquiring their central axis; (Stage 4) measuring the distance of central axis pre- and postinstrumentation. The green line, red line and white line represented the central axis of original root canal, the central axis of enlarged root canal, and the outline of root canal respectively.

Wu et al. BMC Oral Health (2015) 15:27 Page 3 of 7 PTN with a single-length technique recommended by the manufacturer. Each file was used in a progressive up-and-down motion within 3 times and then taken out. The canals were irrigated with distilled water until no debris was seen in the blocks. All the canals were prepared with X-Smart Plus endodontic motor and a 6:1 reduction ratio contra-angle handpiece (Dentsply Maillefer). The speed of motor was set at 300 rpm with 3 Ncm torque when PathFile, PTU and PTN were used; while the program was set at WaveOne mode when WO was used. Image processing A retainer platform for fixing a camera (Canon EOS 50D, Canon Incorporated, Tokyo, Japan) and resin blocks was made in order to take photographs pre- and postinstrumentation at the same position. Before instrumentation, black dye (Winsor & Newton, Colart Tianjin Art Materials, Tianjin, China) was filled into canals and then photographs were taken to record the shapes of original canals; after instrumentation, red dye (Winsor & Newton) was filled into canals to record the shapes of enlarged ones. When taking photographs, a file with silicon stopper Figure 2 Image processing of S-shaped canal. (Stage 1A) the photograph was desaturated before instrumentation; (Stage 1B) the photograph was desaturated after instrumentation; (Stage 2A) the image was converted into vector one before instrumentation; (Stage 2B) the image was converted into vector one after instrumentation; (Stage 3) images pre- and postinstrumentation were superimposed into one after acquiring their central axis; (Stage 4) measuring the distance of central axis pre- and postinstrumentation. The green line, red line and white line represented the central axis of original root canal, the central axis of enlarged root canal, and the outline of root canal respectively.

Wu et al. BMC Oral Health (2015) 15:27 Page 4 of 7 Table 1 Mean transportation ± standard deviation (in millimeters) of central axis after instrumentation at 10 points from apical constriction in L-shaped root canals Group 0 mm 1 mm 2 mm 3 mm 4 mm 5 mm 6 mm 7 mm 8 mm 9 mm PTU 0.06 ± 0.03 b 0.06 ± 0.03 a 0.06 ± 0.04 a,b 0.05 ± 0.04 a 0.10 ± 0.06 a 0.16 ± 0.05 a 0.11 ± 0.04 a 0.06 ± 0.04 a 0.04 ± 0.04 a 0.05 ± 0.04 a WO 0.10 ± 0.03 b 0.11 ± 0.03 b 0.07 ± 0.04 b 0.06 ± 0.04 a 0.16 ± 0.04 b 0.22 ± 0.04 b 0.16 ± 0.03 b 0.07 ± 0.02 a 0.03 ± 0.01 a 0.02 ± 0.01 a PTN 0.05 ± 0.02 a 0.07 ± 0.04 a 0.06 ± 0.02 a 0.06 ± 0.04 a 0.11 ± 0.03 a 0.16 ± 0.02 a 0.10 ± 0.02 a 0.07 ± 0.02 a 0.07 ± 0.03 b 0.08 ± 0.03 b P value <0.05 <0.05 <0.05 >0.05 <0.05 <0.05 < 0.05 >0.05 < 0.05 < 0.05 Within the same column, values with same superscript letter were not statistically different. was inserted into the canals as a marker. These photographs were then processed through software as follows: 1. All the photographs were inputted into software Adobe Photoshop CS6 (Adobe System, San José, CA, USA). And then they were desaturated and saved as JPEG format (Figures 1, and2, Stage 1A and Stage 1B). 2. The desaturated images were inputted into software Able Software R2V for Windows (Able Software, Lexington, USA) in order to converse these images into vector ones of DXF format, which facilitated accurate calculations (Figures 1, and2, Stage 2A and Stage 2B). 3. The DXF images were inputted into software CAXA (CAXA Technology, Peking, China). With the help of CAXA, the outline of canals could easily be described. Moreover, the central axis of canals was acquired. 4. The images of original canals and enlarged ones were superimposed into one picture with the aid of software Adobe Photoshop CS6 after being dealt with CAXA. The outline of original canals was erased. Thus, the central axis of canals pre- and postinstrumentation together with the outline of enlarged canals was remained (Figures 1, and 2, Stage 3). 5. The merged images were inputted into software Image-Pro Plus 6.0 (Media Cybernetics, Warrendale, USA). Centering on apical point, the first circle was drawn with 1 mm radius. And then the next circle centered on the crossover point of the previous circle and the central axis of original canals, and so on until the 10th circle was acquired. In L-shaped canals, points 0 to 2 corresponded to the apical section, points 3 to 7 to the curved section, and points 8 to 9 to the straight section of canals. In S-shaped canals, points 0 to 4 corresponded to the apical curve, points 3 to 7 to the coronal curve [9], and points 8 to 9 to the straight section (Figures 1, and 2, Stage4). 6. The transportation of central axis was measured based on the silicon stopper mounted on each file whose diameter was 3 mm, and defined that the left side of original central axis was negative, the right positive; the deviated angles of L-shaped canals were measured according to Schneider method [10]; and the S-shaped canals were measured according to Cunningham s method [11]. Data analysis All these data were analyzed by IBM SPSS Statistics version 19 (SPSS China, Shanghai, China). Assuming that the populations were normally distributed and homogeneity of variance, the one-way analysis of variance could be used. Otherwise independent samples of nonparametric tests were used. The level of significance was set at P < 0.05. Results Central axis transportation In simulated L-shaped root canals, PTN caused less transportation of central axis than WO at apical section and curved section (P < 0.05) (Table 1 and Figure 3); and PTU also caused less transportation than WO at curved section (P < 0.05). Meanwhile, PTN maintained apical constriction best among the 3 groups (P < 0.05). But PTN produced more transportation compared with PTU and WO at straight section (P < 0.05). In simulated S-shaped root canals, all the files straightened the curvatures significantly (Table 2 and Figure 4). Moreover, group PTU deviated from the central axis further than the other groups at 2 mm (P < 0.05). Figure 3 Mean transportation of central axis after instrumentation in L-shaped root canals. The vertical axis represented the average distance from central axis of original canals, defined that the left side of original central axis was negative and the right was positive.

Wu et al. BMC Oral Health (2015) 15:27 Page 5 of 7 Table 2 Mean transportation ± standard deviation (in millimeters) of central axis after instrumentation at 10 points from apical constriction in S-shaped root canals Group 0 mm 1 mm 2 mm 3 mm 4 mm 5 mm 6 mm 7 mm 8 mm 9 mm PTU 0.08 ± 0.04 a 0.07 ± 0.05 a 0.16 ± 0.04 b 0.12 ± 0.05 a 0.05 ± 0.06 a 0.17 ± 0.05 a 0.19 ± 0.04 a 0.12 ± 0.05 a 0.05 ± 0.04 a 0.06 ± 0.03 a WO 0.06 ± 0.04 a 0.06 ± 0.03 a 0.12 ± 0.03 a 0.12 ± 0.05 a 0.05 ± 0.04 a 0.18 ± 0.06 a 0.21 ± 0.06 a 0.13 ± 0.05 a 0.06 ± 0.03 a 0.04 ± 0.04 a PTN 0.08 ± 0.07 a 0.06 ± 0.04 a 0.12 ± 0.05 a 0.12 ± 0.04 a 0.04 ± 0.03 a 0.15 ± 0.06 a 0.17 ± 0.07 a 0.09 ± 0.06 a 0.06 ± 0.04 a 0.04 ± 0.03 a P value >0.05 > 0.05 <0.05 >0.05 >0.05 >0.05 >0.05 >0.05 >0.05 >0.05 Within the same column, values with same superscript letter were not statistically different. Curvature straightening In simulated L-shaped root canals, the original angle was 30 degree. And PTN maintained the canal curvature best (P < 0.05) while PTU straightened the curvature most (P < 0.05) (Table 3). In simulated S-shaped root canals, the original angle of coronal curvature was 20 degree and the apical one was 30 degree. PTN maintained the coronal curvature best (P < 0.05) while WO straightened the coronal curvature most (P < 0.05). But all files straightened the apical curvature visibly and there was no significant difference among them (P > 0.05) (Table 3). Discussion The present study compared the shaping ability of PTU, WO and PTN in simulated L-shaped and S-shaped root canals. The simulated L-shaped root canals of 30 degree were severely curved canals [10] and the S-shaped were multi-curved [12]. The null hypothesis was rejected. The results of the present study showed that in severely curved canals, PTN caused less transportation at apical section and better maintained canal curvature, even though PTN produced more transportation at straight section compared with PTU and WO; in multi-curved canals, PTN caused the least coronal curvature straightened, but all the files straightened the apical curvature. Figure 4 Mean transportation of central axis after instrumentation in S-shaped root canals. The vertical axis represented the average distance from central axis of original canals, defined that the left side of original central axis was negative and the right was positive. In both types of canals, the great transportation appeared at the corresponding curved sections, and all the files tended to pull curved canals into straight ones. Multiple factors can affect the shaping ability of Ni-Ti files such as alloy microstructure, taper, cross-sectional geometry, movements and system composition. So far, there are mainly 3 phases of microstructure of Ni-Ti wire: austenite, martensite, and R-phase. Ni-Ti alloy displays strong and hard when in austenite phase and it displays flexible and ductile when in martensite phase [13]. The microstructure of PTU is mostly consisted of austenite [14], while WO and PTN are newly invented files whose microstructure is mainly consisted of martensite [15]. And PTU straightened the canal curvature most in severely curved canals. American Dental Association defined the taper of endodontic files as 0.02 in 1981, and allowed the variation within 0.05 mm in 2001 [16]. So there are 3 types of tapers: constant taper, progressive taper (from apical to coronal) and decreasing taper [17,18]. It is claimed that progressive taper increases the flexibility of files while decreasing taper makes files much stiffer [19]. For PTU, S1 and S2 have a progressive taper, while F1 and F2 have a decreasing taper [17]. SX is designed to flare root canal orifice, S1 to prepare the coronal one-third of root canals, S2 to prepare the middle one-third, F1 and F2 to prepare the apical one-third and further enlarge the middle one-third of root canals. For WO, WO primary has a decreasing taper. For PTN, X1 and X2 have a progressive taper at the apical section while a decreasing taper at the coronal section [20]. The progressive taper of Table 3 Mean values ± standard deviation of straightened degree from original angles after instrumentation in L-shaped and S-shaped root canals In L-shaped canals In S-shaped canals Group Straightened angles ( ) Coronal curvature ( ) Apical curvature ( ) PTU 6.00 ± 1.09 c 6.32 ± 0.80 b 22.51 ± 3.45 a WO 4.73 ± 0.54 b 7.31 ± 0.73 c 20.44 ± 2.02 a PTN 0.90 ± 1.58 a 5.19 ± 1.42 a 21.03 ± 2.21 a P value <0.05 <0.05 >0.05 Within the same column, values with same superscript letter were not statistically different.

Wu et al. BMC Oral Health (2015) 15:27 Page 6 of 7 PTN makes it more flexible than PTU and WO at the apical section. Thus, PTN caused the least transportation at apical section in severely curved canals. Each file system has benefits and weaknesses. Crosssectional geometry of Ni-Ti files are various such as triangle, rectangle, slender-rectangle, or square. Some studies find that files with square cross section have the highest screw-in force and flexural stiffness followed by the rectangular ones, the triangular ones and the slenderrectangle ones [21,22]. PTU has a cross section of convex triangle [23]. WO changes cross sections over the working length from a modified convex triangle in the tip region to a convex triangle similar to PTU near the shaft [24]. And PTN has an off-centred rectangular cross section which makes the files rotated in a unique asymmetric motion like a snake [5]. Therefore, PTN, the rectangular cross section together with a decreasing taper at the coronal section, had higher screw-in force and flexural rigidity than PTU and WO, which resulted in more transportation at the straight section in severely curved canals. Up to now, there have been two sorts of file system composition, that is, single-file system and multi-file system. Single-file system usually associates with reciprocating motions (ie, WO and Reciproc), while multi-file system with continuous rotation (ie, PTU and PTN). It is demonstrated reciprocation has better performance than continuous movements [25]. But the present study exhibited that WO produced more transportation at curved parts than PTU and PTN in severely curved canals. That is probably because the single-file system with sharp cutting edges could provide high cutting efficiency, which brings about more canal transportation than multi-file system. Conclusions According to the study, PTN could cause less transportation at apical section and better maintain the canal curvature than PTU and WO in severely curved canals. In addition, PTN could better preserve the coronal curvature than PTU and WO in multi-curved canals, although all the files straightened the apical curvature visibly. Abbreviations PTU: ProTaper Universal; WO: WaveOne; PTN: ProTaper Next; Ni-Ti: Nickel-Titanium. Competing interests The authors declare that they have no competing interests. Authors contributions HW carried out the canals instrumentation, participated in the image processing and drafted the manuscript. CP was involved in the design of the study and revising the manuscript. YB participated in the image processing and performed the statistical analysis. XH, LW, and CL participated in the design of the study and helped to draft the manuscript. All authors have read and approved the final manuscript. Acknowledgments This study is funded by a grand from Tianjin Medical University, Tianjin, China. We thank Professor Ligeng Wu for revising the manuscript. Author details 1 School of Stomatology, Tianjin Medical University, #12 Qi Xiang Tai Road, He Ping District, Tianjin 300070, PR China. 2 Department of Stomatology, The Second Hospital of Tianjin Medical University, Tianjin Medical University, Tianjin, China. Received: 30 November 2014 Accepted: 19 February 2015 References 1. Schilder H. Cleaning and shaping the root canal. Dent Clin North Am. 1974;18(2):269 96. 2. Hülsmann M, Peters OA, Dummer PMH. Mechanical preparation of root canals: shaping goals, techniques and means. Endod Top. 2005;10(1):30 76. 3. Yin LY, Xie XL, Chen MM, Liu LH, Ling TY. [Experimental study of preparing curved root canals with different instrument]. Hua Xi Kou Qiang Yi Xue Za Zhi. 2008;26(6):660 3. 4. Berutti E, Chiandussi G, Paolino DS, Scotti N, Cantatore G, Castellucci A, et al. Effect of canal length and curvature on working length alteration with WaveOne reciprocating files. J Endod. 2011;37(12):1687 90. 5. Elnaghy AM. Cyclic fatigue resistance of ProTaper Next nickel-titanium rotary files. Int Endod J. 2014;47:1034 9. 6. Lim KC, Webber J. The validity of simulated root canals for the investigation of the prepared root canal shape. Int Endod J. 1985;18(4):240 6. 7. Capar ID, Ertas H, Ok E, Arslan H, Ertas ET. Comparative study of different novel nickel-titanium rotary systems for root canal preparation in severely curved root canals. J Endod. 2014;40(6):852 6. 8. Yoo YS, Cho YB. A comparison of the shaping ability of reciprocating NiTi instruments in simulated curved canals. Restor Dent Endod. 2012;37(4):220 7. 9. Burroughs JR, Bergeron BE, Roberts MD, Hagan JL, Himel VT. Shaping ability of three nickel-titanium endodontic file systems in simulated S-shaped root canals. J Endod. 2012;38(12):1618 21. 10. Schneider SW. A comparison of canal preparations in straight and curved root canals. Oral Surg Oral Med Oral Pathol. 1971;32(2):271 5. 11. Cunningham CJ, Senia ES. A three-dimensional study of canal curvatures in the mesial roots of mandibular molars. J Endod. 1992;18(6):294 300. 12. Nagy CD, Szabo J, Szabo J. A mathematically based classification of root canal curvatures on natural human teeth. J Endod. 1995;21(11):557 60. 13. Shen Y, Zhou HM, Zheng YF, Peng B, Haapasalo M. Current challenges and concepts of the thermomechanical treatment of nickel-titanium instruments. J Endod. 2013;39(2):163 72. 14. Alapati SB, Brantley WA, Iijima M, Schricker SR, Nusstein JM, Li UM, et al. Micro-XRD and temperature-modulated DSC investigation of nickel-titanium rotary endodontic instruments. Dent Mater. 2009;25(10):1221 9. 15. Pereira ES, Gomes RO, Leroy AM, Singh R, Peters OA, Bahia MG, et al. Mechanical behavior of M-Wire and conventional NiTi wire used to manufacture rotary endodontic instruments. Dent Mater. 2013;29(12):e318 24. 16. Chesler MB, Tordik PA, Imamura GM, Goodell GG. Intramanufacturer diameter and taper variability of rotary instruments and their corresponding Gutta-percha cones. J Endod. 2013;39(4):538 41. 17. Schäfer E, Vlassis M. Comparative investigation of two rotary nickel titanium instruments: ProTaper versus RaCe. Part 2: cleaning effectiveness and shaping ability in severely curved root canals of extracted teeth. Int Endod J. 2004;37(4):239 48. 18. Gergi R, Abou RJ, Osta N, Sader J, Naaman A. Taper preparation variability compared to current taper standards using computed tomography. Int J Dent. 2012;2012:265695. 19. Bergmans L, Van Cleynenbreugel J, Beullens M, Wevers M, Van Meerbeek B, Lambrechts P. Progressive versus constant tapered shaft design using NiTi rotary instruments. Int Endod J. 2003;36(4):288 95. 20. Capar ID, Ertas H, Ok E, Arslan H. Comparison of single cone obturation performance of different novel nickel-titanium rotary systems. Acta Odontol Scand. 2014;72(7):537 42. 21. Ha J, Cheung G, Versluis A, Lee C, Kwak S, Kim H. Screw-in tendency of rotary nickel-titanium files due to design geometry. Int Endod J. 2014. [Epub ahead of print] 22. Versluis A, Kim HC, Lee W, Kim BM, Lee CJ. Flexural stiffness and stresses in nickel-titanium rotary files for various pitch and cross-sectional geometries. J Endod. 2012;38(10):1399 403.

Wu et al. BMC Oral Health (2015) 15:27 Page 7 of 7 23. Schäfer E, Vlassis M. Comparative investigation of two rotary nickel titanium instruments: ProTaper versus RaCe. Part 1. Shaping ability in simulated curved canals. Int Endod J. 2004;37(4):229 38. 24. Burklein S, Hinschitza K, Dammaschke T, Schafer E. Shaping ability and cleaning effectiveness of two single-file systems in severely curved root canals of extracted teeth: Reciproc and WaveOne versus Mtwo and ProTaper. Int Endod J. 2012;45(5):449 61. 25. Giuliani V, Di Nasso L, Pace R, Pagavino G. Shaping ability of WaveOne primary reciprocating files and ProTaper system used in continuous and reciprocating motion. J Endod. 2014;40(9):1468 71. Submit your next manuscript to BioMed Central and take full advantage of: Convenient online submission Thorough peer review No space constraints or color figure charges Immediate publication on acceptance Inclusion in PubMed, CAS, Scopus and Google Scholar Research which is freely available for redistribution Submit your manuscript at www.biomedcentral.com/submit