Instructions for Use. IJ Catheter Ultrasound Model Version 2400 Series

Similar documents
CATHETERIZATION TRAINER ON A STAND

Parts identification:

Quick Start Guide. Venipuncture and Intramuscular Injection Training Arm

Table of Contents. Dialysis Port Care Chemotherapy Port Care G-Tube Care Colostomy Bags Wound Dressings

WARNING: Products may contain dry natural rubber. Products by Nasco

Arterial Puncture Wrist

Instructions for Use Enbrel (en-brel) (etanercept) for injection, for subcutaneous use Multiple-dose Vial

Instructions for Use Enbrel (en-brel) (etanercept) injection, for subcutaneous use Single-dose Prefilled Syringe

Rhino Clear Sprint Atomizer

limbsandthings.com Advanced Female Catheterisation Trainer User Guide For more skills training products visit Limbs & Things Ltd.

Three Vein Pad - Venepuncture. Extended ACF Pad - Venepuncture

Diagnostic and Procedural Ear Trainer LF01090U Instruction Manual

Drainage Frequency: PATIENT GUIDE. Dressing Frequency: Every Drainage Weekly Drainage. Physician Contact Information. Dr. Phone:

Arterial Puncture Wrist

Education for self administration of intravenous therapy HOME IV THERAPY. 30 minute - Baxter Pump Tobramycin

How to Set Up and Infuse Your TPN

Nursing Kid. Directions for Use Laerdal Medical. All rights reserved rev. B Printed in US

Instructions for Use. For use with. 10 mg vial

limbsandthings.com Advanced Catheterisation Trainer User Guide For more skills training products visit Limbs & Things Ltd.

Sharps Container (not included) 1 Gather and check supplies. Gather supplies

Petite Wound Drainage System. 13mm CWV Drainage System. CWSump. CWV with Trocar

How to Use ENBREL : Vial Adapter Method

Instructions for Use Neulasta (nu-las-tah) (pegfilgrastim) Injection, for subcutaneous use Single-Dose Prefilled Syringe. Plunger rod Used plunger rod

Convalescent Kelly. Directions for Use

In-Service Home Care Training Simulator. Directions for Use

Instructions For Use PRALUENT (PRAHL-u-ent) (alirocumab) Injection, for Subcutaneous Injection Single-Dose Pre-Filled Syringe (75 mg/ml)

Instructions for Use. BASAGLAR KwikPen. insulin glargine injection (100 units/ml, 3 ml pen)

Home Health Foundation, Inc. To create more permanent IV access for patients undergoing long term IV therapy.

Instructions for Use. HUMALOG KwikPen. insulin lispro injection (rdna origin) 100 units/ml, 3 ml pen

CENTRAL VENOUS CANNULATION SIMULATOR LF01087U INSTRUCTION MANUAL

Education for Self Administration of Intravenous Therapy HOME IV THERAPY PICC. Portacath

Chapter 5: Checking and Maintaining Ultrasound Equipment

Understanding your HICKMAN CATHETER

ASEPT. Pleural Drainage System INSTRUCTIONS FOR USE REF LOT STERILE EO. Manufactured for: 824 Twelfth Avenue Bethlehem, PA

ompanionport Speciality Medical Devices For The Veterinary Community Surgical Suggestions

INSTRUCTIONS FOR USE TYMLOS (tim lows ) (abaloparatide) injection, for subcutaneous use

SCIG INFUSIONS A PRACTICAL GUIDE FOR PATIENTS

Central Venous Catheter Care and Maintenance (includes catheter troubleshooting guide)

Instructions for Use. Welcome!

Instructions for Use HEMLIBRA (hem-lee-bruh) (emicizumab-kxwh) injection, for subcutaneous use

Giving Medicine by Subcutaneous Injection

Instructions for Use Enbrel (en-brel) (etanercept) Single-use Prefilled SureClick Autoinjector

Central venous access devices for children with lysosomal storage disorders

ASEPT. Pleural Drainage System INSTRUCTIONS FOR USE. Rx only REF LOT. STERILE EO Sterilized using ethylene oxide

Aus Artificial Uretheral Sphincter Port System

Heart phantom for testing of MRI guided catheter intervention

HUMULIN 70/30 KwikPen

Better Post-Op Pain Control Starts Here

WHAT DO I NEED TO KNOW ABOUT MY VASCULAR ACCESS? FISTULA/GRAFT

PLEASE READ THIS USER MANUAL BEFORE USE

The Enbrel SureClick autoinjector is a single-dose prefilled autoinjector. It contains one 50 mg dose of Enbrel.

Child Intraosseousseous Infusion/Femoral Access Leg LF03614U Instruction Manual

CIMZIA (certolizumab pegol)

Standard Operating Procedure for cannulation

Venepuncture and Cannulation. Louise Smith Clinical Nurse Specialist

Injectable Training Arm LF03214U

Advanced Catheterisation Trainer User Guide

Instructions and User Guide. Midscapular Thoracentesis Ultrasound Training Model BPTT June 8, 2011 Rev 1.0

Pollen Slide Mounting Protocol

Bryan-Dumon Series II Rigid Bronchoscope and Stent Placement Kit USER MANUAL

INJECTABLE TRAINING ARM LF00698 INSTRUCTION MANUAL

DISCOVER NEW HORIZONS IN FLUID DRAINAGE. Bringing Safety and Convenience to Fluid Drainage Management

The next step in dialysis catheter technology

A step-by-step preparation guide

Procedures/Risks:central venous catheter

Inspection Window. Syringe Body

A step-by-step preparation guide

I SEE THE BROADEST RANGE OF PRODUCTS THRU my smallest possible incision.*

Document No. BMB/IFU/40 Rev No. & Date 00 & 15/11/2017 Issue No & Date 01 & 15/11/2017

The Enbrel SureClick autoinjector is a single-dose prefilled autoinjector. It contains one 50 mg dose of Enbrel.

Central Line Care and Management

HumaPen LUXURA HD INSULIN DELIVERY DEVICE INSTRUCTIONS FOR USE

Urological Care. External Male Catheters. Gizmo Male External Catheter. Freedom Clear Advantage Catheter. Freedom Cath Catheter

Central Venous Access Devices. Stephanie Cunningham Amy Waters

SymlinPen (SĬM-lĭnPen) 120 (pramlintide acetate) Pen-Injector

MYALEPT (MAI-uh-lept) (metreleptin) for injection for subcutaneous use

ARTERIAL PUNCTURE ARM INSTRUCTION MANUAL

WHAT DO I NEED TO KNOW ABOUT MY VASCULAR ACCESS? CATHETER

Instruction Manual Aerogen, Inc. Part No. AG-AL1010 Rev. C

ASEPT Pleural Drainage System

IMPORTANT: PLEASE READ. Don t

UW MEDICINE PATIENT EDUCATION. Peritoneal Dialysis. A treatment option for kidney disease. There are 2 types of PD: continuous ambulatory

Patient Information Publications Warren Grant Magnuson Clinical Center National Institutes of Health

Specimen Collection Policies

EVOGAM. Information for patients Evogam 2014 NZ Patient Brochure Update v11

The little book of sound. A step-by-step quick guide to using your LOF hearing aid

Acknowledgement goes to WHO for use of their hand washing technique

Mary Lou Garey MSN EMT-P MedFlight of Ohio

Peritoneal Drainage System

I n s t r u c t i o n M a n u a l

Children's (Pediatric) PICC Line Placement

Galt Medical Corp. A leader in vascular and interventional medical devices. part of the GaltNeedleTech TM Family

EVOGAM. Information for patients Evogam NZ Patient Brochure Update FA3

HumaPen SAVVIO INSULIN DELIVERY DEVICE INSTRUCTIONS FOR USE

Catheters and Wires. Dr. Vaibhav Jain MD,DNB,MNAMS Senior Consultant, IR Medanta, the Medicity, Gurgaon

SECTION VIII: ANNEX D: MALE CONDOM INSPECTION, SAMPLING AND TESTING SPECIFICATIONS PRE-SHIPMENT TESTING

UW MEDICINE PATIENT EDUCATION. Hemodialysis. A treatment option for kidney disease. Treatment Options for Kidney Disease

Solutions Urological Care

Acute Therapy Systems. provencare Catheter Sets

For use only with Lilly 3 ml insulin cartridges (100 units/ml). Do not use other brands of insulin cartridges.

Transcription:

Instructions for Use IJ Catheter Ultrasound Model Version 2400 Series 3601 Sagamore Parkway North, Suite B Lafayette, IN 47904 Phone 765.742.4813 www.hemocleanse.com Instructions Revision 3.0 2014

Table of Contents Page Component Photos Torso 3 Heart Bulb, Reservoir and Tubes 3 Neck and Vascular Insert 4 Equipment and Supplies 5 Operating Procedures Overview 6 Subcutaneous Layer Installation 7 Vein Replacement 8 Install Vascular Insert 10 Install Neck 11 Fill and Connect Heart Bulb 12 Install Water Reservoir 13 Install Subcutaneous Tunnels 14 Cannulation 15 Cleaning, Storage & Maintenance 18 Anatomy of Neck Vasculature 19 Replacement Components 20 IJ Catheter Ultrasound Model Series 2400 Page 2 Revision 3.0

Component Photos Torso Water Reservoir Holder Catheter Tunneling Sites Skin Assembly Torso Spine Heart Bulb, Reservoir, and Connector Tubes Water Reservoir Neck - Reservoir Tube Heart Bulb & Tube IJ Catheter Ultrasound Model Series 2400 Page 3 Revision 3.0

Component Photos Vascular Insert, Back View Internal Jugular Vein Neck - Reservoir Tube Connector Carotid Arteries Spine Heart Bulb Tube Connector Neck Spine Door Latches Superior Vena Cava Left Brachio cephalic Vein Door Latches for Vascular Insert Subcutaneous Layer IJ Catheter Ultrasound Model Series 2400 Page 4 Revision 3.0

Equipment and Supplies Equipment Torso Skin Assembly Neck Vascular Insert (inside Neck) Skin Assembly Heart Bulb with tube Water Reservoir Neck - Reservoir Tube 400 ml beaker (water container) Supplies / Spare Parts IJ Veins Latex Penrose tubing, 6 inches Subcutaneous Layer Rubber Sheet Arteries Latex tubing, 6 inches long O-rings for holding IJ Veins and Arteries O-ring for Vascular Insert Tunneling site cover Velcro Silicone grease IJ Catheter Ultrasound Model Series 2400 Page 5 Revision 3.0

Overview 1. This device is designed to train medical personnel to cannulate the internal jugular vein with large catheters for hemodialysis or other procedures requiring large catheters placed for long duration. 2. Preparing to use the model requires the following steps: Replace IJ veins and, if necessary, arteries Install Vascular Insert into neck Replace the Subcutaneous Layer in the neck Install neck into torso Install heart bulb and water reservoir Install Skin Assembly Install Velcro for subcutaneous tunnel Apply ultrasound gel between the skin assembly and the Subcutaneous Layer. 3. Each Subcutaneous Layer and vein should last for several cannulations. It is not necessary to change the Subcutaneous Layer and vein after each cannulation. Longevity of the Subcutaneous Layer is mostly determined by the availability of suitable places to insert the catheter. Each puncture of the Subcutaneous Layer will leak a small amount of water; much of the water will collect inside the torso. 4. Replacing an artery should not be necessary unless it is punctured during the cannulation procedure. 5. The model is shipped with new Subcutaneous Layer, new veins, and new arteries installed. IJ Catheter Ultrasound Model Series 2400 Page 6 Revision 3.0

Subcutaneous Layer Installation 1. Open the door latches, the outside latches first, then the center latch. 2. Open the door, and remove the rubber sheet (Subcutaneous Layer ). Here the neck is shown with the Subcutaneous Layer removed. 3. Place the Subcutaneous Layer in the door. The side of the rubber sheet fits next to the hinge. Center it in the door. 4. Close the door with the Subcutaneous Layer. 5. Close the center latch first, then the other latches. This centers the door, thereby reducing stress on the outer latches. 6. Check the Subcutaneous Layer placement by looking from the inside. The Subcutaneous Layer should have at approximately the same amount of overlap of the neck all the way around the hole. IJ Catheter Ultrasound Model Series 2400 Page 7 Revision 3.0

Vein Replacement 1 Note: Artery Replacement If an artery tube needs to be replaced, it is easier to replace the artery BEFORE the vein is replaced. The procedure is similar to the steps below. 1. Here is the Vascular Insert with one of the veins removed. 2. The vein can be removed by rolling the O-ring toward the center of the vein and then pulling the vein off the tube. Keep the O-rings, discard the vein tube. 3. Set the Vascular Insert upright on a stable surface. It is recommended to start with the flat, inside end of the Vascular Insert. Slide one end of the vein tubing onto the tube. Put the two O-rings on the vein tubing. 4. Roll an O-ring onto the tube until it reaches the recess. IJ Catheter Ultrasound Model Series 2400 Page 8 Revision 3.0

Vein Replacement 2 4. Installing the other end of the vein is easiest if the Vascular Insert is on a stable surface. Here it is shown inverted on top of the neck. The other end of the veins has been installed over the tube. Vein should be stretched so that it is taut. This facilitates insertion of the catheter. 5. Roll the O-rings onto the tube until it reaches the recess. Two O-rings on each end of the vein insures that it will remain taut. 6. Vein installation is now complete. Notes on Artery Replacement The arteries may be replaced using the same procedure as veins. Artery installation is easier if it is done with the adjacent vein removed, before the vein is installed. Wetting the inside of the artery will make installation easier. IJ Catheter Ultrasound Model Series 2400 Page 9 Revision 3.0

Install Vascular Insert 1. Add about 1300 ml water to the neck. This is best done where overflow from the neck can be contained. 2. Install the Vascular Insert in the neck. Align the spine of the Vascular Insert with the spine in the neck. 3. Slowly lower the Vascular Insert into the neck. A small amount of water should overflow out of the neck. Here is the Vascular Insert ready to be latched to the neck. 4. Latch the Vascular Insert to the neck. A small amount of water may squirt out of the top of the Vascular Insert as the air is purged from the arteries and veins. IJ Catheter Ultrasound Model Series 2400 Page 10 Revision 3.0

Install Neck 1. Align the spine of the neck with the spine in the torso. Slide the neck into the torso, being careful to get the latches inside the torso. 2. Neck is fully installed when the stop is seated in the slot in the torso. Neck locating stop IJ Catheter Ultrasound Model Series 2400 Page 11 Revision 3.0

Fill and Connect Heart Bulb 1. Fill reservoir about 3/4 full of water. 2. Connect heart tubing to reservoir. 3. Install reservoir in holder. The heart tubing goes into interior of holder so that it does not kink. 4. Holding the bulb with the tube upright, pump it several times until bulb is completely filled, and air bubbles no longer come out. 5. Install light tan colored connector on the heart bulb tube into the light tan colored connector on the Vascular Insert. IJ Catheter Ultrasound Model Series 2400 Page 12 Revision 3.0

Install Water Reservoir 1. Fill water reservoir at least half full of water. 2. Install neck-reservoir tube in the reservoir. Close the clamp on the tube. 3. Place reservoir in its holder with the cap down inside. 4. Purge air from the tube by opening the clamp. Clamp to stop water flow. 5. Install the white connector of the neck-reservoir tube in white connector on Vascular Insert. 6. Open the clamp. 7. Replenish water in the reservoir as necessary. IJ Catheter Ultrasound Model Series 2400 Page 13 Revision 3.0

Install Subcutaneous Tunnels 1. Model without Velcro top pieces. Position the Skin Assembly so that the catheter entrance and exit sites are desirable. 2. Velcro tunnels simulate the subcutaneous tissue that the catheter must traverse. Place a Velcro piece on each side of the model with the tunnel exit site under the skin exit site. The tunnel should be directed toward the catheter insertion site. 3. Add ultrasound gel to each catheter insertion site. Notes: Spare Velcro pieces can be used to make custom subcutaneous tunnels. The standard subcutaneous tunnel is 4 3/16 inch (105mm) long with a centered catheter insertion hole 3/16 by 1/2 inch (5 x 12 mm). IJ Catheter Ultrasound Model Series 2400 Page 14 Revision 3.0

Cannulation, 1 1. To improve realism of ultrasound location of the IJ vein, have an assistant pump the heart bulb. The arteries will pulsate. 2. Put ultrasound gel on the outside of the skin. Insert the needle into the vein using ultrasound to guide the placement. 3. Test needle placement by removing the syringe from the needle and watch the fluid drip out of the needle hub. 4. Advance the guide wire into vein as far as desired. 5. Remove the needle from the vein, leaving the guide wire installed. IJ Catheter Ultrasound Model Series 2400 Page 15 Revision 3.0

Cannulation, 2 6. Insert the tunneling tool through the hole in the Velcro toward the vein. 7. Advance the catheter into the tunnel until the hub is at the skin incision. 8. Insert the first dilator over the guidewire into vein. Remove this dilator. Repeat with next size dilator if desired. 9. Insert the largest dilator and catheter sheath over the guide wire. IJ Catheter Ultrasound Model Series 2400 Page 16 Revision 3.0

Cannulation, 3 10. Remove the dilator and guidewire. 11. Insert the catheter into the sheath. Split the sheath hub. 12. Pull the two halves of the sheath apart until the sheath is completely removed. 13. Fully installed catheter. IJ Catheter Ultrasound Model Series 2400 Page 17 Revision 3.0

Cleaning, Storage & Maintenance CLEANING Drain all water from Neck, Reservoir, and connecting tube. Wash Skin Assembly, Neck and Torso with warm water and mild detergent to remove ultrasonic gel. If mold grows on the rubber parts after they have been stored wet, discard the veins and arteries, rinse the Vascular Insert and neck with 10% chlorine bleach and install new veins and arteries. Clean the surface of the neck and door on the neck where it had contacted the Subcutaneous Layer. Residual from the latex sheet can build up and reduce the sealing ability of the door. Allow to air dry thoroughly. STORAGE Store the model with the latches on the Subcutaneous Layer Clamp and the Neck Insert OPEN. If the models are stored long periods of time in operating condition, the plastic parts will tend to deform under stress and the sealing ability may be reduced. MAINTENANCE Latch Problems If lid latch sticks, check that the hook is straight with respect to the body and re-latch. Vascular Insert O-ring Do not install this O-ring by rolling it on, because it will then roll off. Instead, stretch it and put it in place. It will stay in place after it has been used for a while. If the neck leaks at the O-ring, remove, wash, and re-install the O-ring. If small leaks persist, apply a small amount of silicone grease to the O-ring. IJ Catheter Ultrasound Model Series 2400 Page 18 Revision 3.0

Anatomy of the Neck Vasculature Neck Vasculature Illustration from: http://accweb.itr.maryville.edu/myu/image/thyroidvein.gif IJ Catheter Ultrasound Model Series 2400 Page 19 Revision 3.0

Replacement Components IJ Vein Penrose tubing, 3/4 inch diameter x 6 inches long (about 1¼ in wide when flat) [Kendall Argyle Latex Penrose Tubing # 515601] O-ring 3/4 ID by 1/16 thick, extra hard Buna-N, Size 018 [McMaster-Carr part number 5308T127] Carotid Artery Latex tubing, super soft, 5/16 inch ID, 1/16 inch wall, 6 inches long [McMaster-Carr part 5234K34] O-ring: 3/8 ID by 1/16 thick, extra hard Buna-N, Size 012 [McMaster-Carr part number 5308T121] Subcutaneous Layer Natural latex rubber film, 0.050 inch thick x 6.1 inch x 4.5 inch [McMaster-Carr part number 85995K32] Clear: Silicone rubber, 1/16 inch thick x 6.1 inch x 4.5 inch [McMaster-Carr part number 86915K16] Seal for Vascular Insert O-ring: 3-3/8 ID by 1/8 thick, medium soft Buna-N, Size 237 [McMaster-Carr part number 2418T192] Subcutaneous Tunnel Velcro, 2 inch wide, sew-on Hole for inserting catheter is 3/16 x 1/2 inch (5 x 12 mm) Insertion site is 2.0 inches (50 mm) from each end of Velcro piece Skin Assembly Natural latex rubber film, 0.020 inch thick x 13.0 in wide x 10.0 in [McMaster-Carr part number 8611K16] Velcro loop patches are attached with heavy duty staples Silicone Grease Dow Corning Molykote 111 McMaster P/N 1204K32 Most replacement parts can be purchased from McMaster-Carr Supply Company, Inc. at www.mcmaster.com. Penrose tubing for the IJ vein can be purchased from medical supply companies. HemoCleanse will supply replacement parts upon request. Contact David Carr at dcarr@hemocleanse.com IJ Catheter Ultrasound Model Series 2400 Page 20 Revision 3.0